CEN/TC 216/WG 1 - Human medicine
To establish standardized methods of test and requirements for the antimicrobial efficacy of chemical disinfectants and antiseptics intended to prevent the transmission of microorganisms and to prevent infections to humans. The field of application applies therefore to areas and situations where disinfection or antiseptics are medically indicated.
Human medicine
To establish standardized methods of test and requirements for the antimicrobial efficacy of chemical disinfectants and antiseptics intended to prevent the transmission of microorganisms and to prevent infections to humans. The field of application applies therefore to areas and situations where disinfection or antiseptics are medically indicated.
General Information
This document specifies a test method simulating practical conditions for establishing whether a product for hygienic handrub reduces the release of virus contamination on hands when rubbed onto the artificially contaminated hands of volunteers.
NOTE 1 Attention is drawn to the fact that tests on human volunteers are the subject of legal provisions in certain European countries/regions.
This document is applicable to products for hygienic handrub for use in areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes;
and can occur in the workplace and in the home. It can also include services such as laundries and kitchens supplying products directly for the patient.
EN 14885 specifies in detail the relationship of the various tests to one another and to “use recommendations”.
NOTE 2 This method corresponds to a phase 2, step 2 test.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
requirements for sporicidal activity against spores of Clostridioides difficile of chemical disinfectant products that form a homogeneous, physically stable preparation when diluted with hard water - or in the case of ready-to-use products - with water.
This document is applicable to products that are used in the medical area for disinfecting non-porous surfaces including surfaces of medical devices by wiping - regardless if they are covered by the 93/42/EEC Directive on Medical Devices or not.
Due to the new methods of application of surface disinfectants like pre-impregnated wipes this document was established to cover the different application method.
The document is applicable for four method of application of products for wiping and/or mopping:
a) soaking any non-specified wipe or mop with product;
b) spraying the product on any non-specified wipe and / or mop or a specified wipe or mop.
c) impregnation of specified wipes or mops by the user with the product according to the manufacturer’s recommendation;
d) pre-impregnation of specified wipes or mops by the manufacturer as ready-to-use wipes or mops.
In all types of application the water control has to be done with the standard wipe [5.3.2.17 a)], because it is a process or method control.
This document does not apply to products that are sprayed on or flooding surfaces, then left until the contact application phase 2, step 2 standards without mechanical action should be used and their methods performed.
The test surface (5.3.2.16) was selected as standard surface and should cover all non-porous surfaces. It was not intended to cover the influence of each different surface.
This document is applicable to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE This method corresponds to a phase 2, step 2 test.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
This document defines rules for the interpretation of data according to EN 16615: 2015 regarding water controls in order to avoid problems in discussions with legal bodies on the validity of data to support product claims.
- Technical report6 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method and the minimum requirements for the microbicidal activity of a specified disinfection process for the treatment of contaminated textile. This procedure is carried out by using a washing machine as specified in 5.3.2.18 and refers to the disinfection step without prewash. This procedure is not limited to certain types of textile. The suppliers' instructions are expected to be sufficient if they content the process parameters identified in the test (e.g. dosing disinfectant in whatever washing phase e.g. main wash, rinsing, disinfecting at 40 °C).
This document applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities, and in dental institutions;
- in clinics of schools, of kindergartens, and of nursing homes;
and could occur in the workplace and in the home.
It could also include services such as laundries and kitchens supplying products directly for the patients.
The method described is intended to determine the activity of a product or product combination under the conditions in which they are used. This is a phase 2, step 2 laboratory test that simulates the conditions of application of the product.
EN 14885 specifies in detail the relationship of the various tests to one another and to “use recommendations”.
- Standard48 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method and the minimum requirements for fungicidal or yeasticidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water, or - in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less (97 % with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance.
This document applies to products that are used in the medical area in the fields of hygienic handrub, hygienic handwash, surgical handrub, surgical handwash, instrument disinfection by immersion, and surface disinfection by wiping, spraying, flooding or other means.
This document applies to areas and situations where disinfection or antisepsis is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes;
and can occur in the workplace and in the home. It can also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2 step 1 test.
EN 14885 specifies in detail the relationship of the various tests to one another and to “use recommendations”.
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method and the minimum requirements for bactericidal and yeasticidal and additionally fungicidal activity of chemical disinfectant products that form a homogeneous, physically stable preparation when diluted with hard water - or in the case of ready-to-use products - with water.
NOTE Dilutions are necessary as three concentrations in the active to non-active range are tested.
This document applies to products that are used in the medical area for disinfecting non-porous surfaces without mechanical action.
This document applies to areas and situations where disinfection or antisepsis is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes;
and can occur in the workplace and in the home. It can also include services such as laundries and kitchens supplying products directly for the patients.
EN 14885 specifies in detail the relationship of the various tests to one another and to use recommendations.
Using this document, it is possible to determine the activity of products like commercial formulations or active substances on bacteria and/or fungi in the conditions in which they are used and therefore it corresponds to a phase 2, step 2 test.
This method excludes the evaluation of the activity of products against mycobacteria and bacterial spores.
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method and the minimum requirements for bactericidal activity of chemical disinfectant products intended to be used for treatment in aqueous systems against Legionella pneumophila that form a homogeneous, physically stable preparation when diluted with buffered ferrous hard water or hard water. Whenever Legionella pneumophila poses a risk to human health, this method is suitable for water used in cooling towers and water for general purposes, like spas, pools, showers and other uses. The method is not suitable for electro-chemical disinfection.
The document applies to products used as a single application shock treatment in order to kill Legionella pneumophila. It is not suitable for the evaluation of those products that are dosed continuously into water systems to control the growth of Legionella pneumophila.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2 step 1 test.
NOTE 3 This method does not take into account the fact that Legionella pneumophila is often found in cells of amoebae and/or biofilms and that thereby a product’s activity against the bacteria may be reduced.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendation".
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for virucidal activity of chemical disinfectant and antiseptic products that form a homogeneous physically stable preparation when diluted with hard water or in the case of ready-to-use products, i. e, products that are not diluted when applied, with water. Products can only be tested at a concentration of 80 % (97 %, with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance.
This European Standard applies to products that are used in the medical area in the fields of hygienic handrub, hygienic handwash, instrument disinfection by immersion, surface disinfection by wiping, spraying, flooding or other means and textile disinfection.
This European Standard applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities, and in dental institutions;
- in clinics of schools, of kindergartens, and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2, step 1 test.
NOTE 3 EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
- Standard43 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method and the minimum requirements for virucidal activity of chemical disinfectants that form a homogeneous physically stable preparation when diluted with hard water - or in the case of ready-to-use products - with water.
This document applies to products that are used in the medical area for disinfecting non-porous surfaces including surfaces of medical devices without mechanical action.
This document applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities, and in dental institutions;
- in clinics of schools, of kindergartens, and of nursing homes;
and may occur in the workplace and in the home.
It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances on viruses in the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2, step 2 test.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method and the minimum requirements for sporicidal activity of chemical disinfectant that form a homogeneous, physically stable preparation when diluted with hard water, or - in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less (97 % with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance.
This European Standard applies to products that are used in the medical area in the fields of instrument disinfection by immersion, and surface disinfection by wiping, spraying, flooding or other means.
This European Standard applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2, step 1 test.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
- Standard59 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method and the minimum requirements for virucidal activity of chemical disinfectant products that form a homogeneous, physically stable preparation when diluted with hard water - or in the case of ready-to-use products - with water.
This document applies to products that are used in the medical area for disinfecting instruments by immersion.
This document applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes;
- and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2, step 2 test.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method simulating practical conditions for establishing whether a product for surgical handrub and handwash reduces the release of resident and eventually present transient microbial flora on hands when used for the treatment of clean hands of volunteers.
This European Standard applies to products for surgical handrub or handwash for use in areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes.
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patient.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
NOTE This method corresponds to a phase 2, step 2 test.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for bactericidal and yeasticidal activity of chemical disinfectant products that form a homogeneous, physically stable preparation when diluted with hard water – or in the case of ready-to-use products – with water.
This European Standard applies to products that are used in the medical area for disinfecting non-porous surfaces including surfaces of medical devices by wiping – regardless if they are covered by the 93/42/EEC Directive on Medical Devices or not.
This European Standard includes ‘ready-to-use wipes‘ which are impregnated with a microbicidal solution.
This European Standard applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE This method corresponds to a phase 2, step 2. test.
EN 14885 specifies in detail the relationship of the various tests to one another and to “use recommendations”.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for bactericidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water, or - in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less (97 % with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance.
This European Standard applies to products that are used in the medical area in the fields of hygienic handrub, hygienic handwash, surgical handrub, surgical handwash, instrument disinfection by immersion, and surface disinfection by wiping, spraying, flooding or other means.
This European Standard applies to areas and situations where disinfection or antisepsis is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2 step 1 test.
NOTE 3 This method cannot be used to evaluate the activity of products against Legionella in watersystems and against mycobacteria.
EN 14885 specifies in detail the relationship of the various tests to one another and to 'use recommendations'.
- Standard52 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method simulating practical conditions for establishing whether a product for hygienic handrub reduces the release of transient microbial flora on hands when rubbed onto the artificially contaminated hands of volunteers.
NOTE 1 Attention is drawn to the fact that tests on human volunteers are the subject of legal provisions in certain European countries/regions.
This European Standard applies to products for hygienic handrub for use in areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions,
- in clinics of schools, of kindergartens and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patient.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
NOTE 2 This method corresponds to a phase 2, step 2 test.
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method simulating practical conditions for establishing whether a product for hygienic handwash reduces the release of transient microbial flora on hands when used to wash the artificially contaminated hands of volunteers.
NOTE 1 Attention is drawn to the fact that tests on human volunteers are the subject of legal provisions in certain European countries/regions.
This European Standard applies to products for hygienic handwash for use in areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions,
- in clinics of schools, of kindergartens and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patient.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
NOTE 2 This method corresponds to a phase 2, step 2 test.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for mycobactericidal or tuberculocidal activity of chemical disinfectant products that form a homogeneous, physically stable preparation when diluted with hard water, or – in the case of ready-to-use products – with water.
This European Standard applies to products that are used in the medical area for disinfecting instruments by immersion – even if they are not covered by the EEC/93/42 Directive on Medical Devices.
This European Standard applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
in hospitals, in community medical facilities and in dental institutions;
in clinics of schools, kindergartens and nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
NOTE This method corresponds to a phase 2, step 2 test.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for bactericidal activity of chemical disinfectant products that form a homogeneous, physically stable preparation when diluted with hard water - or in the case of ready-to-use products - with water.
This European Standard applies to products that are used in the medical area for disinfecting instruments by immersion - even if they are not covered by the EEC/93/42 Directive on Medical Devices.
This European Standard applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergardens and of nursing homes;
- and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE This method corresponds to a phase 2, step 2 test (see Annex E).
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for fungicidal or yeasticidal activity of chemical disinfectant products for instruments that form a homogeneous, physically stable preparation when diluted with hard water - or in the case of ready-to-use products - with water.
This European Standard applies to products that are used in the medical area for disinfecting instruments by immersion - even if they are not covered by the EEC/93/42 Directive on Medical Devices.
This European Standard applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergardens and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE This method corresponds to a phase 2, step 2 test (see Annex E).
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method and the minimum requirements for mycobactericidal (or tuberculocidal) activity of chemical disinfectant products that form a homogeneous, physically stable preparation when diluted with hard water - or in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less as some dilution is always produced by adding the test organisms and interfering substance.
This document applies to products that are used in the medical area including those that are covered by the EEC/93/42 Directive on Medical Devices.
This document applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergardens and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2, step 1 test (see Annex E).
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method and the minimum requirements for the microbicidal activity of a specified disinfection process for the treatment of contaminated textile. This procedure is carried out by using a washing machine as specified in 5.3.2.18 and refers to the disinfection step without prewash. This procedure is not limited to certain types of textile. The suppliers' instructions are expected to be sufficient if they content the process parameters identified in the test (e.g. dosing disinfectant in whatever washing phase e.g. main wash, rinsing, disinfecting at 40 °C).
This document applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities, and in dental institutions;
- in clinics of schools, of kindergartens, and of nursing homes;
and could occur in the workplace and in the home.
It could also include services such as laundries and kitchens supplying products directly for the patients.
The method described is intended to determine the activity of a product or product combination under the conditions in which they are used. This is a phase 2, step 2 laboratory test that simulates the conditions of application of the product.
EN 14885 specifies in detail the relationship of the various tests to one another and to “use recommendations”.
- Draft6 pagesEnglish languagesale 10% offe-Library read for1 day
TThis document specifies a test method and the minimum requirements for virucidal activity of chemical disinfectant and antiseptic products that form a homogeneous physically stable preparation when diluted with hard water - or in the case of ready-to-use products, i.e, products that are not diluted when applied, - with water. Ready-to-use-products can only be tested at a concentration up to 80 % (97 %, with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance.
This document applies to products that are used in the medical area in the fields of hygienic handrub, hygienic handwash, instrument disinfection by immersion, surface disinfection by wiping, spraying, flooding or other means and textile disinfection.
This document applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities, and in dental institutions;
- in clinics of schools, of kindergartens, and of nursing homes;
and can occur in the workplace and in the home. It can also include services such as laundries and kitchens supplying products directly for the patient.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2, step 1 test.
NOTE 3 EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
- Draft45 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method and the minimum requirements for bactericidal and yeasticidal, fungicidal, tuberculocidal and/or mycobactericidal activity of chemical disinfectant products that form a homogeneous, physically stable preparation when diluted with hard water - or in the case of ready-to-use products - with water.
This document applies to products that are used in the medical area for disinfecting non-porous surfaces including surfaces of medical devices by wiping or mopping - regardless if they are covered by the 93/42/EEC Directive on Medical Devices or not.
Due to the new methods of application of surface disinfectants like pre-impregnated wipes this standard was established to cover the different application method.
prEN 16615 is applicable for four methods of application of products for wiping and/or mopping:
a) soaking any non-specified wipe or mop with product;
b) spraying the product on any non-specified wipe and / or mop or a specified wipe or mop;
c) impregnation of specified wipes or mops by the user with the product according to the manufacturer’s recommendation;
d) pre-impregnation of specified wipes or mop by the manufacturer as ready-to-use wipes or mops.
In all types of application, the water control is done with the standard wipe [5.3.2.17.1], because it is a process or method control.
This document does not apply to products that are sprayed on or flooding surfaces, and then left until the contact application phase 2, step 2 standards without mechanical action should be used and their methods performed.
The test surface (5.3.2.16) was selected as standard surface and should cover all non-porous surfaces. It was not intended to cover the influence of each different surface.
This document applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes;
and can occur in the workplace and in the home. It can also include services such as laundries and kitchens supplying products directly for the patients.
NOTE This method corresponds to a phase 2, step 2 test.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
- Draft53 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method simulating practical conditions for establishing whether a product for hygienic handrub reduces the release of virus contamination on hands when rubbed onto the artificially contaminated hands of volunteers.
NOTE 1 Attention is drawn to the fact that tests on human volunteers are the subject of legal provisions in certain European countries/regions.
This document applies to products for hygienic handrub for use in areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergardens and of nursing homes;
and-can occur in the workplace and in the home. It can also include services such as laundries and kitchens supplying products directly for the patient.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
NOTE 2 This method corresponds to a phase 2, step 2 test.
- in clinics of schools, of kindergardens and of nursing homes.
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patient.
EN 14885 specifies in detail the relationship of the various tests to one another and to “use recommendations”.
NOTE 2 This method corresponds to a phase 2, step 2 test.
- Draft30 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for virucidal activity of chemical disinfectants that form a homogeneous physically stable preparation when diluted with hard water - or in the case of ready-to-use products - with water.
This European Standard applies to products that are used in the medical area for disinfecting non-porous surfaces including surfaces of medical devices without mechanical action.
This European Standard applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities, and in dental institutions;
- in clinics of schools, of kindergartens, and of nursing homes;
and may occur in the workplace and in the home.
It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances on viruses in the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2, step 2 test.
EN 14885 specifies in detail the relationship of the various tests to one another and to 'use recommendations'.
- Draft31 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for virucidal activity of
chemical disinfectant and antiseptic products that form a homogeneous physically stable preparation when
diluted with hard water – or in the case of ready-to-use products, i. e, products that are not diluted when
applied,– with water. Products can only be tested at a concentration of 80 % (97 %, with a modified method
for special cases) as some dilution is always produced by adding the test organisms and interfering
substance.
This European Standard applies to products that are used in the medical area in the fields of hygienic
handrub, hygienic handwash, instrument disinfection by immersion, surface disinfection by wiping, spraying,
flooding or other means and textile disinfection.
This European Standard applies to areas and situations where disinfection is medically indicated. Such
indications occur in patient care, for example:
in hospitals, in community medical facilities, and in dental institutions;
in clinics of schools, of kindergartens, and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens
supplying products directly for the patients.
- Draft7 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method and the minimum requirements for virucidal activity of chemical disinfectants or antiseptic products for instruments, surfaces or hands that form a homogeneous physically stable preparation when diluted with hard water or in the case of ready-to-use products with water.
This document is applicable to a broad spectrum of viruses (Annex B) and to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities, and in dental institutions;
- in clinics of schools, of kindergartens, and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
It is impossible to determine the virucidal activity of the undiluted product as some dilution is always produced by adding the inoculum and interfering substance.
However, a disinfectant or antiseptic which is used in undiluted form is tested in 80% concentration and shall pass this test prior to further assessment.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2, step 1 test (see Annex F).
- Draft3 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for virucidal activity of chemical disinfectant and antiseptic products that form a homogeneous physically stable preparation when diluted with hard water or in the case of ready-to-use products, i. e, products that are not diluted when applied, with water. Products can only be tested at a concentration of 80 % (97 %, with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance.
This European Standard applies to products that are used in the medical area in the fields of hygienic handrub, hygienic handwash, instrument disinfection by immersion, surface disinfection by wiping, spraying, flooding or other means and textile disinfection.
This European Standard applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities, and in dental institutions;
- in clinics of schools, of kindergartens, and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2, step 1 test.
NOTE 3 EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
- Draft8 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for bactericidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water, or - in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less (97 % with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance. This European Standard applies to products that are used in the medical area in the fields of hygienic handrub, hygienic handwash, surgical handrub, surgical handwash, instrument disinfection by immersion, and surface disinfection by wiping, spraying, flooding or other means. This European Standard applies to areas and situations where disinfection or antisepsis is medically indicated. Such indications occur in patient care, for example: in hospitals, in community medical facilities and in dental institutions; in clinics of schools, of kindergartens and of nursing homes; and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
- Draft6 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies test methods and minimum requirements for virucidal activity of chemical disinfectants or antiseptic products for instruments, surfaces, laundry or hands that form a homogeneous physically stable preparation in water.
This document is applicable to a broad spectrum of viruses (see Annex B) and to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
¾ in hospitals, in community medical facilities, and in dental institutions;
¾ clinics of schools, kindergartens, and nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
It is impossible to determine the virucidal activity of the undiluted product as some dilution is always produced by adding the inoculum. However, a disinfectant or antiseptic which is used in undiluted form is tested in 80% concentration and shall pass this test prior to further assessment.
- Draft4 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for bactericidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water, or - in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less (97 % with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance. This European Standard applies to products that are used in the medical area in the fields of hygienic handrub, hygienic handwash, surgical handrub, surgical handwash, instrument disinfection by immersion, and surface disinfection by wiping, spraying, flooding or other means. This European Standard applies to areas and situations where disinfection or antisepsis is medically indicated. Such indications occur in patient care, for example: - in hospitals, in community medical facilities and in dental institutions; - in clinics of schools, of kindergartens and of nursing homes; and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients. NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used. NOTE 2 This method corresponds to a phase 2 step 1 test. NOTE 3 This method cannot be used to evaluate the activity of products against Legionella in watersystems and against mycobacteria. EN 14885 specifies in detail the relationship of the various tests to one another and to 'use recommendations'.
- Draft5 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method simulating practical conditions for establishing whether a product for surgical handrub and handwash reduces the release of resident and eventually present transient microbial flora on hands when used for the treatment of clean hands of volunteers.
This European Standard applies to products for surgical handrub or handwash for use in areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes.
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patient.
EN 14885 specifies in detail the relationship of the various tests to one another and to “use recommendations”.
NOTE This method corresponds to a phase 2, step 2 test.
- Draft15 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for the microbicidal activity of a defined disinfection process for the treatment of contaminated linen. This procedure is carried out by using a washing machine as defined in Chapter 5.3.2.17 and refers to the disinfection step without prewash.
This European Standard applies to areas and situations where disinfection is indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in schools, kindergartens and nursing homes;
- institutions where patients are accommodated, which could suffer from transmissible diseases;
- other applications where hygienic treatment of linen is necessary (e.g. food processing, hotels, workwear e. g. from the pharmaceutical industry, laboratories, foodstuffs area or similar institutions).
The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE This method corresponds to a phase 2 step 2 test (Annex F).
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for fungicidal or yeasticidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water, or - in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less (97 % with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance.
This European Standard applies to products that are used in the medical area in the fields of hygienic handrub, hygienic handwash, surgical handrub, surgical handwash, instrument disinfection by immersion, and surface disinfection by wiping, spraying, flooding or other means.
This European Standard applies to areas and situations where disinfection or antisepsis is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2 step 1 test.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
- Standard54 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for bactericidal activity of chemical disinfectant products intended to be used for treatment in aqueous systems against Legionella pneumophila that form a homogeneous, physically stable preparation when diluted with buffered ferrous hard water or hard water. Whenever Legionella pneumophila poses a risk to human health, this method is suitable for water used in cooling towers and water for general purposes, like spas, pools, showers and other uses. The method is not suitable for electro-chemical disinfection.
The European Standard applies to products used to treat water in order to kill Legionella pneumophila.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2 step 1 test .
NOTE 3 This method does not take into account the fact that Legionella pneumophila is often found in cells of amoebae and/or biofilms and that thereby a product’s activity against the bacteria may be reduced.
EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendation".
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for virucidal activity of chemical disinfectant and antiseptic products that form a homogeneous physically stable preparation when diluted with hard water or in the case of ready-to-use products, i. e, products that are not diluted when applied, with water. Products can only be tested at a concentration of 80 % (97 %, with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance.
This European Standard applies to products that are used in the medical area in the fields of hygienic handrub, hygienic handwash, instrument disinfection by immersion, surface disinfection by wiping, spraying, flooding or other means and textile disinfection.
This European Standard applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities, and in dental institutions;
- in clinics of schools, of kindergartens, and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2, step 1 test.
NOTE 3 EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method simulating practical conditions for establishing whether a product for surgical handrub and handwash reduces the release of resident and eventually present transient microbial flora on hands when used for the treatment of clean hands of volunteers.
This European Standard applies to products for surgical handrub or handwash for use in areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes.
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patient.
EN 14885 specifies in detail the relationship of the various tests to one another and to “use recommendations”.
NOTE This method corresponds to a phase 2, step 2 test.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method simulating practical conditions for establishing whether a product for surgical hand disinfection reduces the release of hand flora according to requirements described in clause 4 when used for the disinfection of the clean hands of volunteers.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for bactericidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water, or - in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less (97 % with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance.
This European Standard applies to products that are used in the medical area in the fields of hygienic handrub, hygienic handwash, surgical handrub, surgical handwash, instrument disinfection by immersion, and surface disinfection by wiping, spraying, flooding or other means.
This European Standard applies to areas and situations where disinfection or antisepsis is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2 step 1 test.
NOTE 3 This method cannot be used to evaluate the activity of products against Legionella in watersystems and against mycobacteria.
EN 14885 specifies in detail the relationship of the various tests to one another and to 'use recommendations'.
- Standard52 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for virucidal activity of chemical disinfectant and antiseptic products that form a homogeneous physically stable preparation when diluted with hard water or in the case of ready-to-use products, i. e, products that are not diluted when applied, with water. Products can only be tested at a concentration of 80 % (97 %, with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance.
This European Standard applies to products that are used in the medical area in the fields of hygienic handrub, hygienic handwash, instrument disinfection by immersion, surface disinfection by wiping, spraying, flooding or other means and textile disinfection.
This European Standard applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities, and in dental institutions;
- in clinics of schools, of kindergartens, and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2, step 1 test.
NOTE 3 EN 14885 specifies in detail the relationship of the various tests to one another and to "use recommendations".
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for bactericidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water, or - in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less (97 % with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance.
This European Standard applies to products that are used in the medical area in the fields of hygienic handrub, hygienic handwash, surgical handrub, surgical handwash, instrument disinfection by immersion, and surface disinfection by wiping, spraying, flooding or other means.
This European Standard applies to areas and situations where disinfection or antisepsis is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2 step 1 test.
NOTE 3 This method cannot be used to evaluate the activity of products against Legionella in watersystems and against mycobacteria.
EN 14885 specifies in detail the relationship of the various tests to one another and to 'use recommendations'.
- Standard52 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for fungicidal or yeasticidal activity of chemical disinfectant products that form a homogeneous, physically stable preparation when diluted with hard water or - in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less as some dilution is always produced by adding the test organisms and interfering substance.
This European Standard applies to products that are used in the medical area for disinfecting instruments by immersion - even if they are not covered by the EEC/93/42 Directive on Medical Devices.
This European Standard applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example :
- in hospitals, in community medical facilities and in dental institutions ;
- in clinics of schools, of kindergartens and of nursing homes ;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2 step 1 test (see annex E).
- Standard39 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method and the minimum requirements for virucidal activity of chemical disinfectants or antiseptic products for instruments, surfaces or hands that form a homogeneous physically stable preparation when diluted with hard water – or in the case of ready-to-use products - with water.
This document is applicable to a broad spectrum of viruses (Annex B) and to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities, and in dental institutions;
- in clinics of schools, of kindergartens, and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
It is impossible to determine the virucidal activity of the undiluted product as some dilution is always produced by adding the inoculum and interfering substance. However, a disinfectant or antiseptic which is used in undiluted form is tested in 80% concentration and shall pass this test prior to further assessment.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2, step 1 test (see Annex F).
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a method of test simulating practical conditions for establishing whether a product for hygienic handrub reduces the release of transient flora according to requirements when rubbed onto the artificially contaminated hands of volunteers. This European Standard applies to products for hygienic handrub for use in areas and situations where disinfection is medically indicated.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a method of test simulating practical conditions for establishing whether a product for hygienic handwash reduces the release of transient flora according to the requirements when used for washing the artificially contaminated hands of volunteers. This European Standard applies to products for hygienic handwash for use in areas and situations where disinfection is medically indicated. Such indications occur in patient care, forexample: - in hospitals, in community medical facilities and in dental institutions; - in clinics of schools, of kindergardens and of nursing homes.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a test method and the minimum requirements for bactericidal activity of chemical disinfectant products that form a homogeneous, physically stable preparation when diluted with hard water - or in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less as some dilution is always produced by adding the test organisms and interfering substance.
This European Standard applies to products that are used in the medical area for disinfecting instruments by immersion - even if they are not covered by the EEC/93/42 Directive on Medical Devices.
This European Standard applies to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
- in hospitals, in community medical facilities and in dental institutions;
- in clinics of schools, of kindergartens and of nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
NOTE 1 The method described is intended to determine the activity of commercial formulations or active substances under the conditions in which they are used.
NOTE 2 This method corresponds to a phase 2 step 1 test (see annex E).
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies test methods and minimum requirements for virucidal activity of chemical disinfectants or antiseptic products for instruments, surfaces, laundry or hands that form a homogeneous physically stable preparation in water.
This document is applicable to a broad spectrum of viruses (see Annex B) and to areas and situations where disinfection is medically indicated. Such indications occur in patient care, for example:
¾ in hospitals, in community medical facilities, and in dental institutions;
¾ clinics of schools, kindergartens, and nursing homes;
and may occur in the workplace and in the home. It may also include services such as laundries and kitchens supplying products directly for the patients.
It is impossible to determine the virucidal activity of the undiluted product as some dilution is always produced by adding the inoculum. However, a disinfectant or antiseptic which is used in undiluted form is tested in 80% concentration and shall pass this test prior to further assessment.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day