SIST EN 301 441 V2.2.1:2026
(Main)Satellite Earth Stations and Systems (SES) - Mobile Earth Stations (MES), including handheld earth stations, for Satellite Personal Communications Networks (S-PCN) operating in the 1,6 GHz/2,4 GHz frequency band under the Mobile Satellite Service (MSS) - Harmonised Standard for access to radio spectrum
- Abstract
The present document applies to Mobile Earth Station (MES) radio equipment which have the following characteristics:
• the MES has both transmit and receive capabilities and operate in a Satellite-Personal Communications Network (S-PCN). An S-PCN MES can be a handheld, portable, vehicle-mounted, host connected, semi-fixed or fixed equipment, or can be an element in a multi-mode terminal. It consists of a number of modules with associated connections and user interface, or can be a self-contained single unit;
• these MESs are controlled and monitored by Control Monitoring Functions (CMF). The CMF is outside the scope of the present document;
• if the MES is an element in a multi-mode terminal, unless otherwise stated in the present document, its requirements apply only to the S-PCN MES element of the terminal operating in the MSS frequency bands given in table 1;
• the MES is capable in operating in all or part of the frequency bands shown in table 1.
NOTE: The relationship between the present document and essential requirements of article 3.2 of Directive 2014/53/EU [i.3] is given in annex A.
- Status
- Published
- Public Enquiry End Date
- 27-Sep-2026
- Publication Date
- 05-Oct-2026
- Technical Committee
- MOC - Mobile Communications
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 05-Oct-2026
- Due Date
- 10-Dec-2026
- Completion Date
- 06-Oct-2026
Buy Documents
ETSI EN 301 441 V2.2.0 (2026-07) - Satellite Earth Stations and Systems (SES); Mobile Earth Stations (MES), including handheld earth stations, for Satellite Personal Communications Networks (S-PCN) operating in the 1,6 GHz/2,4 GHz frequency band under the Mobile Satellite Service (MSS); Harmonised Standard for access to radio spectrum
ETSI EN 301 441 V2.2.1 (2026-09) - Satellite Earth Stations and Systems (SES); Mobile Earth Stations (MES), including handheld earth stations, for Satellite Personal Communications Networks (S-PCN) operating in the 1,6 GHz/2,4 GHz frequency band under the Mobile Satellite Service (MSS); Harmonised Standard for access to radio spectrum
SIST EN 301 441 V2.2.1:2026 is the SIST adoption of ETSI EN 301 441 V2.2.1, a harmonised European standard for Mobile Earth Stations (MES) used in Satellite Personal Communications Networks (S-PCN) in the 1,6 GHz/2,4 GHz band under the Mobile Satellite Service (MSS). It specifies the radio-spectrum access limits and test methods for these terminals, including handheld units, so they can be assessed for market access and conformity work. It is aimed at manufacturers, test laboratories, compliance teams, and buyers who need to know what an MES must do and how it is checked.
What does SIST EN 301 441 V2.2.1:2026 specify?
SIST EN 301 441 V2.2.1:2026 applies to MES radio equipment that both transmits and receives in an S-PCN, including handheld, portable, vehicle-mounted, host-connected, semi-fixed, fixed, and multi-mode terminal elements. The focus is on radio spectrum access for the MSS bands used by the MES, while Control and Monitoring Functions (CMF) are handled outside the document itself.
The scope is tied to the bands in Table 1:
- transmit: 1 610 MHz to 1 626,5 MHz
- receive: 1 613,8 MHz to 1 626,5 MHz
- receive: 2 483,5 MHz to 2 500,0 MHz
The document is organized into scope, references, terms, technical requirements, and testing. Annex A links the requirements to Directive 2014/53/EU article 3.2, and the other annexes explain nominated bandwidth, measurement uncertainty, vibration, bibliography, and change history.
| Annex | What it covers |
|---|---|
| Annex A | Relationship with the essential requirements of Directive 2014/53/EU |
| Annex B | Explanation of nominated bandwidth |
| Annex C | Laboratory test equipment and maximum measurement uncertainty |
| Annex D | Vibration characteristics |
| Annex E | Bibliography |
| Annex F | Change history |
What are the key requirements of SIST EN 301 441 V2.2.1:2026?
The standard combines emission limits, control behaviour, receiver performance checks, and a defined test approach. In practice, it tells you what to measure, which operating states to test, and what the equipment must do before it can be considered suitable for the stated MSS use.
Operating conditions and environmental profile
Clause 4.1 requires the MES to meet the technical requirements across its intended environmental profile, including humidity, temperature, and supply voltage. At minimum, the temperature range is -10 °C to +55 °C, and the equipment must comply across the declared voltage extremes.
This matters because the equipment is not only checked at room conditions. The manufacturer must define the voltage range for the intended use and show that performance stays acceptable at the limits.
Unwanted emissions and EIRP limits
Clauses 4.2.1, 4.2.2, 4.2.3, and 4.2.4 set the main radio emission limits. They cover unwanted emissions outside the MSS band, unwanted emissions inside and around the operational band, EIRP density within the operational band, and unwanted emissions in carrier-off state.
In practice, this means the MES must stay within the stated EIRP masks when transmitting and must also keep idle-state emissions low enough to protect other services. The limits depend on frequency, measurement bandwidth, and whether the test is peak or average, so the test plan has to match the exact operating band and carrier state of the equipment.
CMF behaviour and network control
Clause 4.2.5 defines how an MES reacts to network control. After power-on, it must enter a controlled carrier-off state until it is synchronized to the network control channel, and it must stop transmitting within 30 s after losing that channel. The same clause also requires transmission disable and enable handling, transmit frequency control, and restrictions on fellow radio stations in dual-mode or multi-mode terminals.
This is important because the MES must not radiate freely before network authorization. The test team therefore needs a CMF Simulator or equivalent facility to verify that network commands can enable, disable, and steer the carrier correctly.
Equipment identity
Clause 4.2.6 requires each MES to have a unique MES Identification Code (MIC) within its S-PCN. The user must not be able to alter that code through normal access, and the MES must be able to transmit its identity when commanded by CMF.
In practice, this supports network control and traceability. A buyer or integrator should expect the identity function to be fixed and remotely readable, not user-editable.
Receiver protection requirements
Clauses 4.2.7, 4.2.8, and 4.2.9 address interference resilience. The MES must support transmission disable functions for protection of the radio astronomy service in 1 610,6 MHz to 1 613,8 MHz, must meet adjacent-channel selectivity limits, and must meet blocking limits against strong interfering signals.
These checks matter because they show whether the receiver can keep working near other signals and whether the terminal can be controlled to avoid harmful operation in protected bands. The adjacent-channel test allows no more than 0,5 dB degradation in signal-to-noise ratio, while the blocking test allows no more than 1 dB degradation.
Test method and documentation expectations
Clause 5 describes how compliance is demonstrated. It covers environmental test conditions, the use of representative equipment, host-connected and plug-in module configurations, CMF simulation, radiated and conducted measurement methods, and the test report.
For a practical test campaign, this means the EUT documentation must describe the equipment type, antenna arrangement, test modes, extreme voltages, and intended operating band information. It also means the laboratory must record the test setup, conditions, and results, including any measurement uncertainty.
What terms does SIST EN 301 441 V2.2.1:2026 define?
- Carrier-on state - the state in which the MES is actively transmitting a carrier; this is the state tested for operating emissions and control response.
- Carrier-off state - the idle radio state in which the MES is powered but not transmitting a carrier; this is the state used to check low-level unwanted emissions.
- Control and Monitoring Functions (CMF) - the network-driven functions that command or supervise the MES; they are central to authorization, disabling, and frequency control.
- Nominated bandwidth (Bn) - the transmission bandwidth wide enough to contain all spectral elements of the MES signal; it determines the emission mask and test boundaries.
- Operational band - the part of 1 610 MHz to 1 626,5 MHz assigned to the MSS network where the MES operates.
- Host-connected - an MES that needs connection to host equipment to provide its functionality; this affects how the equipment is presented and tested.
- Equivalent Isotropically Radiated Power (EIRP) - transmitter power combined with antenna gain, expressed as if the signal were radiated by an isotropic source.
Who uses SIST EN 301 441 V2.2.1:2026?
Manufacturers of MES equipment use the standard to design terminals for the stated MSS bands and to prepare compliance evidence. Test laboratories use it to set up radiated or conducted measurements, CMF simulations, and receiver tests.
Compliance and regulatory teams use it to check whether the product documentation, operating bands, antenna arrangement, and control functions match the intended use. Network operators and integrators also use it when defining the information needed for an S-PCN terminal, especially for multi-mode or host-connected products.
What changed in SIST EN 301 441 V2.2.1:2026 from the previous edition?
Annex F records the change history leading to this edition, and the publication history shows V2.2.1 as the September 2026 publication following V2.2.0 in July 2026. The recorded revisions include editorial updates, RED-related work, and updates to the preferred test site wording and the OATS reference in earlier V2.1.x steps.
Which standards are used with SIST EN 301 441 V2.2.1:2026?
The document relies on a small set of normative references that support its test methods and environmental conditions:
- ITU-T O.153 - provides the basic pseudorandom bit sequence used for the test modulating signal.
- Final Acts of WRC '95 - underpin the EIRP density basis used in the operational band.
- IEC 60068-2-1 - supplies cold test conditions used for the temperature range.
- IEC 60068-2-2 - supplies dry heat test conditions used for the temperature range.
The informative references connect the standard to its regulatory context:
- Commission Implementing Decision C(2015) 5376 final - the standardisation request under which the harmonised standard was prepared.
- Directive 2014/53/EU - the Radio Equipment Directive whose article 3.2 is mapped in Annex A.
- IEC 60068-2-64 - gives the broadband random vibration guidance used in Annex D.
What does the SIST EN 301 441 V2.2.1:2026 document contain?
Clause 4 contains the technical requirements, with tables for emission limits and receiver test conditions, and clause 5 turns those requirements into step-by-step test procedures. The testing section includes equipment presentation, host-connected configurations, CMF simulation, and procedures for radiated and conducted measurements.
Several figures show the test arrangements, including reference position, substitution measurement, cabinet measurement, and the receiver test setup. Annex B adds graphical examples for choosing nominated bandwidth, Annex C gives measurement uncertainty guidance for the laboratory, and Annex D lists vibration characteristics for environmental testing.
The document is therefore useful both for design verification and for formal compliance testing. It tells a laboratory how to measure, and it tells a manufacturer what the product must be able to do under normal, extreme, and controlled network conditions.
Buy Documents
ETSI EN 301 441 V2.2.0 (2026-07) - Satellite Earth Stations and Systems (SES); Mobile Earth Stations (MES), including handheld earth stations, for Satellite Personal Communications Networks (S-PCN) operating in the 1,6 GHz/2,4 GHz frequency band under the Mobile Satellite Service (MSS); Harmonised Standard for access to radio spectrum
ETSI EN 301 441 V2.2.1 (2026-09) - Satellite Earth Stations and Systems (SES); Mobile Earth Stations (MES), including handheld earth stations, for Satellite Personal Communications Networks (S-PCN) operating in the 1,6 GHz/2,4 GHz frequency band under the Mobile Satellite Service (MSS); Harmonised Standard for access to radio spectrum
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 301 441 V2.2.1:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Satellite Earth Stations and Systems (SES) - Mobile Earth Stations (MES), including handheld earth stations, for Satellite Personal Communications Networks (S-PCN) operating in the 1,6 GHz/2,4 GHz frequency band under the Mobile Satellite Service (MSS) - Harmonised Standard for access to radio spectrum". This standard covers: The present document applies to Mobile Earth Station (MES) radio equipment which have the following characteristics: • the MES has both transmit and receive capabilities and operate in a Satellite-Personal Communications Network (S-PCN). An S-PCN MES can be a handheld, portable, vehicle-mounted, host connected, semi-fixed or fixed equipment, or can be an element in a multi-mode terminal. It consists of a number of modules with associated connections and user interface, or can be a self-contained single unit; • these MESs are controlled and monitored by Control Monitoring Functions (CMF). The CMF is outside the scope of the present document; • if the MES is an element in a multi-mode terminal, unless otherwise stated in the present document, its requirements apply only to the S-PCN MES element of the terminal operating in the MSS frequency bands given in table 1; • the MES is capable in operating in all or part of the frequency bands shown in table 1. NOTE: The relationship between the present document and essential requirements of article 3.2 of Directive 2014/53/EU [i.3] is given in annex A.
The present document applies to Mobile Earth Station (MES) radio equipment which have the following characteristics: • the MES has both transmit and receive capabilities and operate in a Satellite-Personal Communications Network (S-PCN). An S-PCN MES can be a handheld, portable, vehicle-mounted, host connected, semi-fixed or fixed equipment, or can be an element in a multi-mode terminal. It consists of a number of modules with associated connections and user interface, or can be a self-contained single unit; • these MESs are controlled and monitored by Control Monitoring Functions (CMF). The CMF is outside the scope of the present document; • if the MES is an element in a multi-mode terminal, unless otherwise stated in the present document, its requirements apply only to the S-PCN MES element of the terminal operating in the MSS frequency bands given in table 1; • the MES is capable in operating in all or part of the frequency bands shown in table 1. NOTE: The relationship between the present document and essential requirements of article 3.2 of Directive 2014/53/EU [i.3] is given in annex A.
SIST EN 301 441 V2.2.1:2026 is classified under the following ICS (International Classification for Standards) categories: 33.060.30 - Radio relay and fixed satellite communications systems; 33.070.99 - Other mobile services. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 301 441 V2.2.1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 References
- 2.1 Normative references
- 9 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 2.2 Informative references
- 3 Definition of terms, symbols and abbreviations
- 3.1 Terms
- 10 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 11 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 3.2 Symbols
- 3.3 Abbreviations
- 12 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 4 Technical requirements specifications
- 4.1 Environmental profile
- 4.2 Conformance requirements
- 13 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 14 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 15 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 16 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 17 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 18 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 19 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 5 Testing for compliance with technical requirements
- 5.1 Environmental conditions for testing
- 20 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 5.2 Essential radio test suites
- 21 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 22 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 23 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 30 MHz to 12,75 GHz
- 24 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 25 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 26 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 27 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 28 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 29 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 30 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 31 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 32 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 33 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 34 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 35 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 36 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 37 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 38 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 39 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 1 Unwanted emissions outside the band
- 2 Unwanted emissions within the band 3.2 4.2.2 U
- 3 EIRP density within the operational band 3.2 4.2.3 U
- 4 Unwanted emissions in carrier-off state 3.2 4.2.4 U
- 5 Processor monitoring 3.2 The processor monitoring
- 6 Transmit frequency generation 3.2 Individual requirements for
- 7 Network control authorization 3.2 4.2.5.3 U
- 8 Transmission disable/ enable 3.2 4.2.5.4.1 U
- 9 Transmit frequency control 3.2 4.2.5.4.2 U
- 10 Fellow radio stations in a dual-mode or 3.2 4.2.5.5 U
- 11 Equipment identity 3.2 4.2.6 U
- 12 Protection of the radio astronomy service 3.2 4.2.7 U
- 40 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 13 Receiver Adjacent Channel Selectivity 3.2 4.2.8 U
- 14 Receiver Blocking Characteristics 3.2 4.2.9 U
- 15 Receiver co-channel rejection 3.2 4.2.8 U
- 16 Single signal selectivity - receiver 3.2 4.2.8 U
- 20 Receiver multiple signal selectivity - 3.2 4.2.8 U
- 22 Reciprocal mixing 3.2 It is considered that the reciprocal
- 41 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 42 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 43 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 44 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 45 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 46 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 47 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 48 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 5 Hz to 20 Hz
- 20 Hz to 500 Hz
- 49 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- Bibliography
- 50 Draft ETSI EN 301 441 V2.2.0 (2026-07)
- 51 Draft ETSI EN 301 441 V2.2.0 (2026-07)
1 Scope
The present document applies to Mobile Earth Station (MES) radio equipment which have the following characteristics:
- the MES has both transmit and receive capabilities and operate in a Satellite-Personal Communications Network (S-PCN). An S-PCN MES can be a handheld, portable, vehicle-mounted, host connected, semi-fixed or fixed equipment, or can be an element in a multi-mode terminal. It consists of a number of modules with associated connections and user interface, or can be a self-contained single unit; - these MESs are controlled and monitored by Control Monitoring Functions (CMF). The CMF is outside the scope of the present document; - if the MES is an element in a multi-mode terminal, unless otherwise stated in the present document, its requirements apply only to the S-PCN MES element of the terminal operating in the MSS frequency bands given in table 1; - the MES is capable in operating in all or part of the frequency bands shown in table 1. Table 1: Mobile Satellite Service (MSS) frequency bands MES MSS frequency bands Transmit 1 610 MHz to 1 626,5 MHz Receive 1 613,8 MHz to 1 626,5 MHz Receive 2 483,5 MHz to 2 500,0 MHz
NOTE: The relationship between the present document and essential requirements of article 3.2 of Directive 2014/53/EU [i.3] is given in annex A.
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or nonspecific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found in the ETSI docbox.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long-term validity.
The following referenced documents are necessary for the application of the present document. [1] Void.
[2] Recommendation ITU-T O.153 (10/92): "Basic parameters for the measurement of error performance at bit rates below the primary rate".
[3] Void.
[4] Void.
[5] Void.
[6] Final Acts of the World Radiocommunication Conference (WRC '95); Geneva 1995. [7] IEC 60068-2-1 (2025): "Environmental testing - Part 2: Tests. Tests A: Cold". [8] IEC 60068-2-2 (2025): "Environmental testing - Part 2: Tests. Tests B: Dry heat". ETSI
9 Draft ETSI EN 301 441 V2.2.0 (2026-07)
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long-term validity.
The following referenced documents may be useful in implementing an ETSI deliverable or add to the reader's understanding, but are not required for conformance to the present document. [i.1] Void.
[i.2] Commission Implementing Decision C(2015) 5376 final of 4.8.2015 on a standardisation request to the European Committee for Electrotechnical Standardisation and to the European Telecommunications Standards Institute as regards radio equipment in support of Directive 2014/53/EU of the European Parliament and of the Council.
[i.3] Directive 2014/53/EU of the European Parliament and of the Council of 16 April 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment and repealing Directive 1999/5/EC.
[i.4] IEC 60068-2-64:2008+AMD1:2019 CSV: "Environmental testing. Part 2-64: Tests. Test Fh:
Vibration, broadband random and guidance".
3 Definition of terms, symbols and abbreviations
3.1 Terms
For the purposes of the present document, the following terms apply:
carrier-on state (allocated a channel): state in which the MES is transmitting a carrier carrier-off state (idle mode): radio state in which the MES does not actually transmit a carrier CMF control message: message, normally originating from a network, to a specified terminal or set of terminals of the network which indicates to the terminal or set of terminals that it/they carry out some specific action or enter or maintain some specific state NOTE: For test purposes CMF control messages can originate from CMF Simulator. conducted measurement: measurement of emissions from an antenna port of the MES made by direct wired connection to the port environmental profile: range of environmental conditions under which equipment within the scope of the present document is required to comply with the provisions of the present document Equivalent Isotropically Radiated Power (EIRP): product of transmitter power and maximum antenna gain, equivalent to an isotropic source radiating uniformly in all directions fellow radio station: another radio station operating in the same service, frequency band, or coordination environment as the station in question, such that it shares allocated spectrum with the mobile satellite earth terminal handheld: MES which is self-contained and is small enough and light enough to be carried and used during a call with one hand host-connected: MES for which connection to or integration with host equipment is necessary to offer functionality host equipment: any equipment which has a complete user functionality when not connected to the MES, and to which the MES provides additional functionality, and to which connection is necessary for the MES to offer functionality ETSI
10 Draft ETSI EN 301 441 V2.2.0 (2026-07)
in-band signals: signals which are located in the operating band plus an offset of 10 MHz outside this operating band Installable Equipment (IE), Internally Mounted Equipment (IME) And Externally Mounted Equipment (EME):
Installable Equipment (IE) is an equipment which is intended to be installed in a vehicle NOTE: An IE consist of one or several interconnected modules. The IE is composed of modules intended to be externally mounted as defined for the intended use of the MES, and defined as Externally Mounted Equipment (EME) and the remaining modules(s) as Internally Mounted Equipment (IME). Laboratory Test Equipment: logical grouping that contains the standard test equipment provided by a test laboratory MSS band: continuous range of frequencies allocated by the ITU to the MSS multi-mode: equipment that accommodates radio stations of different radio networks narrow-band system: narrow-band system is one in which the nominal carrier frequency spacing for MESs in the earth-to-space direction is less than 300 kHz network control channel: channel by which an MES receives general control information from the CMF(originated by a network control facility) of its S-PCN nominated bandwidth (Bn): Bandwidth of the Mobile Earth Station (MES) radio frequency transmission which is wide enough to encompass all spectral elements of the transmission NOTE 1: The nominated bandwidth is centred on the transmit frequency and does not exceed 5 times the occupied bandwidth.
NOTE 2: The nominated bandwidth is wide enough to take account of the transmit carrier frequency stability. This definition is chosen to allow flexibility regarding adjacent channel interference levels which will be taken into account by operational procedures depending on the exact transponder carrier assignment situation.
NOTE 3: The Bn is defined relative to the MES actual carrier frequency f
Bn is the width of the frequency interval (f -a, f +b), where a and bcan vary with f which are defined c c c for the intended use of the MES. The frequency interval (f -a, f +b) does not encompass more than c c either:
i) when a = b, 4 or less carrier frequencies for narrow-band systems; ii) when a ≠ b, 1 nominal carrier frequency for narrow-band systems; or iii) 1 nominal carrier frequency for wide-band systems.
The frequency interval (f -a, f +b) remains within the operational band of the MES. c c NOTE 4: Further explanation of nominated bandwidth is presented in annex B. operational band: sub-portion of the 1 610 MHz to 1 626,5 MHz band which has been assigned in the earth-to-space direction to the MSS network within which the MES is operating Portable Equipment (PE): generally intended to be self-contained, free standing and portable. A PE would normally consist of a single module, but can consist of several interconnected modules radiated measurement: measurement of an actual radiated field Special Test Equipment (STE): equipment which allows a test laboratory to control the MES so that the tests required by the present document can be performed test laboratory: laboratory which performs the conformance testing of the MES against the present document test load: test load is a substantially non-reactive, non-radiating power attenuator which is capable of safely dissipating the power from the transmitter(s) unwanted emissions: unwanted emissions are those falling outside the nominated bandwidth in the carrier-on state, and those generated in the carrier-off state ETSI
11 Draft ETSI EN 301 441 V2.2.0 (2026-07)
wide-band system: wide-band system is one in which the nominal carrier frequency spacing for MESs in the Earth-to-Space direction is equal to or greater than 300 kHz
3.2 Symbols
Void.
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
AK-R Air Kerma Rate ASD Acceleration Spectral Density BE Lower Band Edge of the operating band L BE Upper Band Edge of the operating band U B Nominated Bandwidth n BW Bandwidth CDMA Code Division Multiple Access CMF Control and Monitoring Functions CW Continuous Wave dBW deciBels relative to 1 Watt EFTA European Free Trade Association EIRP Equivalent Isotropically Radiated Power EMC Electro-Magnetic Compatibility EME Externally Mounted Equipment EN European Standard ERM Electromagnetic compatibility and Radio spectrum Matters ETS European Telecommunication Standard EU European Union EUT Equipment Under Test IE Installable Equipment IEC International Electrotechnical Commission IME Internally Mounted Equipment ITU International Telecommunication Union ITU-T ITU Telecommunication Standardization Sector MES Mobile Earth Station MIC MES unique Identification Code (within its S-PCN) MSS Mobile Satellite Service OATS Open Area Test Site PCN Personal Communications Network PE Portable Equipment R&TTE Radio and Telecommunications Terminal Equipment RE Radio Equipment RED Radio Equipment Directive RF Radio Frequency SNR Signal to Noise Ratio S-PCN Satellite Personal Communications Network STE Special Test Equipment TBR Technical Basis for Regulation WRC World Radiocommunication Conference ZVEI Zentralverband Elektrotechnik- und Elektronik-industrie ETSI
12 Draft ETSI EN 301 441 V2.2.0 (2026-07)
4 Technical requirements specifications
4.1 Environmental profile
4.1.1 General
The technical requirements of the present document apply under the environmental profile for operation of the equipment, which shall be in accordance with its intended use, but as a minimum, shall be that specified in the test conditions contained in the present document. The equipment shall comply with all the technical requirements of the present document at all times when operating within the boundary limits of the specified operational environmental profile defined by its intended use.
The environmental profile for operation of the equipment shall include the ranges of humidity, temperature and supply voltage.
4.1.2 Temperature
The MES shall fulfil all the requirements in the full temperature ranges of:
- -10 °C to +55 °C; taken from IEC publications 60068-2-1 [7] and 60068-2-2 [8].
4.1.3 Voltage
The nominal, lower and the higher extreme voltages shall be defined for the intended use of the MES and provided with the EUT documentation.
The MES shall fulfil all the requirements in the full voltage range between the extreme voltages.
4.2 Conformance requirements
4.2.1 Unwanted emissions outside the band 1 610 MHz to 1 626,5 MHz
and the band 1 626,5 MHz to 1 628,5 MHz (carrier-on)
4.2.1.1 Justification
Protection of other radio services operating outside the band 1 610 MHz to 1 628,5 MHz from emissions caused by S-PCN MESs operating within the band 1 610 MHz to 1 626,5 MHz.
4.2.1.2 Technical requirements
The maximum EIRP density of the unwanted emissions from the MES outside the band 1 610,0 MHz to 1 626,5 MHz and the band 1 626,5 MHz to 1 628,5 MHz shall not exceed the limits in table 3. In table 3, whenever a change of limit between adjacent frequency bands occurs, the lower of the two limits shall apply at the transition frequency.
ETSI
13 Draft ETSI EN 301 441 V2.2.0 (2026-07)
Table 2: Void Table 3: Maximum unwanted emissions outside the band 1 610 MHz to 1 626,5 MHz and the band 1 626,5 MHz to 1 628,5 MHz Frequency Carrier-on (MHz) EIRP (dBW) Measurement bandwidth Measurement method 0,1 to 30 -66 10 kHz Peak-hold 30 to 1 000 -66 100 kHz Peak-hold 1 000 to 1 559 -60 1 MHz Average 1 559 to 1 580,42 -70 1 MHz Average (see note 1) 1 580,42 to 1 605 -70 1 MHz Average 1 605 to 1 610 -70 to -10 1 MHz Average (see note 2) 1 610 to 1 626,5 Not applicable Not applicable Not applicable 1 626,5 to 1 628,5 Not applicable Not applicable Not applicable 1 628,5 to 1 631,5 -60 30 kHz Average 1 631,5 to 1 636,5 -60 100 kHz Average 1 636,5 to 1 646,5 -60 300 kHz Average 1 646,5 to 1 666,5 -60 1 MHz Average 1 666,5 to 2 200 -60 3 MHz Average 2 200 to 12 750 -60 3 MHz Peak hold NOTE 1: In the sub-band 1 573,42 MHz to 1 580,42 MHz, the average measurement time is 20 ms. NOTE 2: Linearly interpolated in dBW vs. frequency offset.
The conformance requirements apply for the full range of environmental conditions corresponding to the type of equipment as specified in clause 4.1.
4.2.1.3 Conformance test
Conformance tests are described in clause 5.2.2.
4.2.2 Unwanted emissions within the band 1 610 MHz to 1 626,5 MHz and
the band 1 626,5 MHz to 1 628,5 MHz (carrier-on)
4.2.2.1 Justification
Protection of radio services and systems operating within the frequency band 1 610 to 1 628,5 MHz from unwanted emissions caused by S-PCN MESs operating in the band 1 610 MHz to 1 626,5 MHz.
4.2.2.2 Technical requirements
The maximum EIRP spectral density of the unwanted emissions from the MES within the band 1 610 MHz to 1 628,5 MHz shall not exceed the limits in tables 4, 5 or 6, as applicable. In tables 4, 5 and 6, whenever a change of limit between adjacent frequency bands occurs, the lower of the two limits shall apply at the transition frequency.
When conflicts between multiple requirements exist, the more stringent requirement applies. ETSI
14 Draft ETSI EN 301 441 V2.2.0 (2026-07)
Table 4: Maximum unwanted emissions within the band 1 610,0 MHz to 1 626,5 MHz and the band 1 626,5 MHz to 1 628,5 MHz of MES operating such that the nominated bandwidth is entirely or partially contained in the frequency band 1 618,25 MHz to 1 626,5 MHz Carrier - on Frequency offset (kHz) EIRP (dBW) Measurement bandwidth (kHz) Measurement (see note 1) (see note 3) (see note 2) method 0 to 160 -35 30 Average 160 to 225 -35 to -38,5 30 Average 225 to 650 -38,5 to -45 30 Average 650 to 1 365 -45 30 Average 1 365 to 1 800 -53 to -56 30 Average 1 800 to 16 500 -56 30 Average NOTE 1: Frequency offset is determined from:
i) the nearest edge of the nominated bandwidth of the nominal carrier closest to the MSS system operating in another operational band within the band 1 610 MHz to 1 626,5 MHz. The frequency offset is measured in the direction of the adjacent MSS system; ii) the upper edge of the nominated bandwidth of the carrier under test for emissions within the band 1 626,5 MHz to 1 628,5 MHz.
NOTE 2: The measurement bandwidth used can be 3 kHz if the unwanted EIRP limits are reduced correspondingly.
NOTE 3: Linearly interpolated in dBW vs. frequency offset.
Table 5: Maximum unwanted emissions within the band 1 610,0 MHz to 1 626,5 MHz and the band 1626,5 MHz to 1628,5 MHz of MES operating such that the nominated bandwidth is entirely contained in the frequency band 1 610,0 MHz to 1 618,25 MHz Carrier - on Frequency offset (kHz) EIRP (dBW) Measurement bandwidth (kHz) Measurement method (see note 1) (see note 3) (see note 2) 0 to 160 -32 30 Average 160 to 2 300 -32 to -56 30 Average 2 300 to 18 500 -56 30 Average NOTE 1: Frequency offset is determined from:
i) the nearest edge of the nominated bandwidth of the nominal carrier closest to the MSS system operating in another operational band within the band 1 610 to 1 626,5 MHz The frequency offset is measured in the direction of the adjacent MSS system; ii) the upper edge of the nominated bandwidth of the carrier under test for emissions within the band 1 626,5 to 1 628,5 MHz.
NOTE 2: The measurement bandwidth used can be 3 kHz if the unwanted EIRP limits are reduced correspondingly.
NOTE 3: Linearly interpolated in dBW vs. frequency offset.
Table 6: Maximum unwanted emissions of MES carriers within the operational band of CDMA carriers Carrier - on Frequency offset (kHz) EIRP (dBW) Measurement bandwidth Measurement (see note 1) (see note 2) (kHz) method 0 to 70 -6 to -20 30 Average 70 to 600 -20 to -28 30 Average 600 to 2 000 -28 to -45 30 Average 2 000 to 5 000 -45 to -69 30 Average 5 000 to 16 500 -69 30 Average NOTE 1: Frequency offset is determined from edge of nominated bandwidth. NOTE 2: Linearly interpolated in dBW vs. frequency offset.
The conformance requirements apply for the full range of environmental conditions corresponding to the type of equipment as specified in clause 4.1.
ETSI
15 Draft ETSI EN 301 441 V2.2.0 (2026-07)
4.2.2.3 Conformance test
Conformance tests are described in clause 5.2.3.
4.2.3 EIRP density within the operational band
4.2.3.1 Justification
To ensure that the maximum EIRP spectral density within the band 1 610 MHz to 1 626,5 MHz does not exceed the limits defined by the Final Acts of WRC-95 [6], S5.364.
4.2.3.2 Technical requirements
In any frequency sub-band of the band 1 610 MHz to 1 626,5 MHz, where the MES operates, one of the two following requirements shall apply under specific operating conditions:
a) The MES shall not produce a mean EIRP density exceeding -3 dB (W/4 kHz), (mean limit). NOTE: In this context, the mean is the mean over time whilst the MES is in the carrier-on mode. Or, b) The MES shall not produce a peak EIRP density exceeding -15 dB (W/4 kHz) (peak limit). The specific frequency sub-band(s) and operating conditions, for which the two different limits apply, shall be defined for the intended use of the MES and provided with the EUT documentation. These requirements apply to all types of MES, for every transmit channel of the MES in its operational band or sub-bands.
The conformance requirements apply for the full range of environmental conditions corresponding to the type of the equipment as described in clause 4.1.
4.2.3.3 Conformance test
Conformance tests are described in clause 5.2.4.
4.2.4 Unwanted emissions in carrier-off state
4.2.4.1 Justification
Protection of other radio services and systems from unwanted emissions caused by MESs in the carrier-off state.
4.2.4.2 Technical requirements
The maximum EIRP of the unwanted emissions from the MESs in the carrier-off state shall not exceed the limits in table 7.
In table 7, whenever a change of limit between adjacent frequency bands occurs, the lower of the two limits shall apply at the transition frequency.
...
Contents
- 1 Scope
- 2 References
- 2.1 Normative references
- 9 ETSI EN 301 441 V2.2.1 (2026-09)
- 2.2 Informative references
- 3 Definition of terms, symbols and abbreviations
- 3.1 Terms
- 10 ETSI EN 301 441 V2.2.1 (2026-09)
- 11 ETSI EN 301 441 V2.2.1 (2026-09)
- 3.2 Symbols
- 3.3 Abbreviations
- 12 ETSI EN 301 441 V2.2.1 (2026-09)
- 4 Technical requirements specifications
- 4.1 Environmental profile
- 4.2 Conformance requirements
- 13 ETSI EN 301 441 V2.2.1 (2026-09)
- 14 ETSI EN 301 441 V2.2.1 (2026-09)
- 15 ETSI EN 301 441 V2.2.1 (2026-09)
- 16 ETSI EN 301 441 V2.2.1 (2026-09)
- 17 ETSI EN 301 441 V2.2.1 (2026-09)
- 18 ETSI EN 301 441 V2.2.1 (2026-09)
- 19 ETSI EN 301 441 V2.2.1 (2026-09)
- 5 Testing for compliance with technical requirements
- 5.1 Environmental conditions for testing
- 20 ETSI EN 301 441 V2.2.1 (2026-09)
- 5.2 Essential radio test suites
- 21 ETSI EN 301 441 V2.2.1 (2026-09)
- 22 ETSI EN 301 441 V2.2.1 (2026-09)
- 23 ETSI EN 301 441 V2.2.1 (2026-09)
- 30 MHz to 12,75 GHz
- 24 ETSI EN 301 441 V2.2.1 (2026-09)
- 25 ETSI EN 301 441 V2.2.1 (2026-09)
- 26 ETSI EN 301 441 V2.2.1 (2026-09)
- 27 ETSI EN 301 441 V2.2.1 (2026-09)
- 28 ETSI EN 301 441 V2.2.1 (2026-09)
- 29 ETSI EN 301 441 V2.2.1 (2026-09)
- 30 ETSI EN 301 441 V2.2.1 (2026-09)
- 31 ETSI EN 301 441 V2.2.1 (2026-09)
- 32 ETSI EN 301 441 V2.2.1 (2026-09)
- 33 ETSI EN 301 441 V2.2.1 (2026-09)
- 34 ETSI EN 301 441 V2.2.1 (2026-09)
- 35 ETSI EN 301 441 V2.2.1 (2026-09)
- 36 ETSI EN 301 441 V2.2.1 (2026-09)
- 37 ETSI EN 301 441 V2.2.1 (2026-09)
- 38 ETSI EN 301 441 V2.2.1 (2026-09)
- 39 ETSI EN 301 441 V2.2.1 (2026-09)
- 1 Unwanted emissions outside the band
- 2 Unwanted emissions within the band 3.2 4.2.2 U
- 3 EIRP density within the operational band 3.2 4.2.3 U
- 4 Unwanted emissions in carrier-off state 3.2 4.2.4 U
- 5 Processor monitoring 3.2 The processor monitoring
- 6 Transmit frequency generation 3.2 Individual requirements for
- 7 Network control authorization 3.2 4.2.5.3 U
- 8 Transmission disable/ enable 3.2 4.2.5.4.1 U
- 9 Transmit frequency control 3.2 4.2.5.4.2 U
- 10 Fellow radio stations in a dual-mode or 3.2 4.2.5.5 U
- 11 Equipment identity 3.2 4.2.6 U
- 12 Protection of the radio astronomy service 3.2 4.2.7 U
- 40 ETSI EN 301 441 V2.2.1 (2026-09)
- 13 Receiver Adjacent Channel Selectivity 3.2 4.2.8 U
- 14 Receiver Blocking Characteristics 3.2 4.2.9 U
- 15 Receiver co-channel rejection 3.2 4.2.8 U
- 16 Single signal selectivity - receiver 3.2 4.2.8 U
- 20 Receiver multiple signal selectivity - 3.2 4.2.8 U
- 22 Reciprocal mixing 3.2 It is considered that the reciprocal
- 41 ETSI EN 301 441 V2.2.1 (2026-09)
- 42 ETSI EN 301 441 V2.2.1 (2026-09)
- 43 ETSI EN 301 441 V2.2.1 (2026-09)
- 44 ETSI EN 301 441 V2.2.1 (2026-09)
- 45 ETSI EN 301 441 V2.2.1 (2026-09)
- 46 ETSI EN 301 441 V2.2.1 (2026-09)
- 47 ETSI EN 301 441 V2.2.1 (2026-09)
- 48 ETSI EN 301 441 V2.2.1 (2026-09)
- 5 Hz to 20 Hz
- 20 Hz to 500 Hz
- 49 ETSI EN 301 441 V2.2.1 (2026-09)
- Bibliography
- 50 ETSI EN 301 441 V2.2.1 (2026-09)
- 51 ETSI EN 301 441 V2.2.1 (2026-09)
1 Scope
The present document applies to Mobile Earth Station (MES) radio equipment which have the following characteristics:
- the MES has both transmit and receive capabilities and operate in a Satellite-Personal Communications Network (S-PCN). An S-PCN MES can be a handheld, portable, vehicle-mounted, host connected, semi-fixed or fixed equipment, or can be an element in a multi-mode terminal. It consists of a number of modules with associated connections and user interface, or can be a self-contained single unit; - these MESs are controlled and monitored by Control Monitoring Functions (CMF). The CMF is outside the scope of the present document; - if the MES is an element in a multi-mode terminal, unless otherwise stated in the present document, its requirements apply only to the S-PCN MES element of the terminal operating in the MSS frequency bands given in table 1; - the MES is capable in operating in all or part of the frequency bands shown in table 1. Table 1: Mobile Satellite Service (MSS) frequency bands MES MSS frequency bands Transmit 1 610 MHz to 1 626,5 MHz Receive 1 613,8 MHz to 1 626,5 MHz Receive 2 483,5 MHz to 2 500,0 MHz
NOTE: The relationship between the present document and essential requirements of article 3.2 of Directive 2014/53/EU [i.3] is given in annex A.
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or nonspecific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found in the ETSI docbox.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long-term validity.
The following referenced documents are necessary for the application of the present document. [1] Void.
[2] Recommendation ITU-T O.153 (10/92): "Basic parameters for the measurement of error performance at bit rates below the primary rate".
[3] Void.
[4] Void.
[5] Void.
[6] Final Acts of the World Radiocommunication Conference (WRC '95); Geneva 1995. [7] IEC 60068-2-1 (2025): "Environmental testing - Part 2: Tests. Tests A: Cold". [8] IEC 60068-2-2 (2025): "Environmental testing - Part 2: Tests. Tests B: Dry heat". ETSI
9 ETSI EN 301 441 V2.2.1 (2026-09)
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long-term validity.
The following referenced documents may be useful in implementing an ETSI deliverable or add to the reader's understanding, but are not required for conformance to the present document. [i.1] Void.
[i.2] Commission Implementing Decision C(2015) 5376 final of 4.8.2015 on a standardisation request to the European Committee for Electrotechnical Standardisation and to the European Telecommunications Standards Institute as regards radio equipment in support of Directive 2014/53/EU of the European Parliament and of the Council.
[i.3] Directive 2014/53/EU of the European Parliament and of the Council of 16 April 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment and repealing Directive 1999/5/EC.
[i.4] IEC 60068-2-64:2008+AMD1:2019 CSV: "Environmental testing. Part 2-64: Tests. Test Fh:
Vibration, broadband random and guidance".
3 Definition of terms, symbols and abbreviations
3.1 Terms
For the purposes of the present document, the following terms apply:
carrier-on state (allocated a channel): state in which the MES is transmitting a carrier carrier-off state (idle mode): radio state in which the MES does not actually transmit a carrier CMF control message: message, normally originating from a network, to a specified terminal or set of terminals of the network which indicates to the terminal or set of terminals that it/they carry out some specific action or enter or maintain some specific state NOTE: For test purposes CMF control messages can originate from CMF Simulator. conducted measurement: measurement of emissions from an antenna port of the MES made by direct wired connection to the port environmental profile: range of environmental conditions under which equipment within the scope of the present document is required to comply with the provisions of the present document Equivalent Isotropically Radiated Power (EIRP): product of transmitter power and maximum antenna gain, equivalent to an isotropic source radiating uniformly in all directions fellow radio station: another radio station operating in the same service, frequency band, or coordination environment as the station in question, such that it shares allocated spectrum with the mobile satellite earth terminal handheld: MES which is self-contained and is small enough and light enough to be carried and used during a call with one hand host-connected: MES for which connection to or integration with host equipment is necessary to offer functionality host equipment: any equipment which has a complete user functionality when not connected to the MES, and to which the MES provides additional functionality, and to which connection is necessary for the MES to offer functionality ETSI
10 ETSI EN 301 441 V2.2.1 (2026-09)
in-band signals: signals which are located in the operating band plus an offset of 10 MHz outside this operating band Installable Equipment (IE), Internally Mounted Equipment (IME) And Externally Mounted Equipment (EME):
Installable Equipment (IE) is an equipment which is intended to be installed in a vehicle NOTE: An IE consist of one or several interconnected modules. The IE is composed of modules intended to be externally mounted as defined for the intended use of the MES, and defined as Externally Mounted Equipment (EME) and the remaining modules(s) as Internally Mounted Equipment (IME). laboratory test equipment: logical grouping that contains the standard test equipment provided by a test laboratory MSS band: continuous range of frequencies allocated by the ITU to the MSS multi-mode: equipment that accommodates radio stations of different radio networks narrow-band system: narrow-band system is one in which the nominal carrier frequency spacing for MESs in the earth-to-space direction is less than 300 kHz network control channel: channel by which an MES receives general control information from the CMF(originated by a network control facility) of its S-PCN nominated bandwidth (Bn): Bandwidth of the Mobile Earth Station (MES) radio frequency transmission which is wide enough to encompass all spectral elements of the transmission NOTE 1: The nominated bandwidth is centred on the transmit frequency and does not exceed 5 times the occupied bandwidth.
NOTE 2: The nominated bandwidth is wide enough to take account of the transmit carrier frequency stability. This definition is chosen to allow flexibility regarding adjacent channel interference levels which will be taken into account by operational procedures depending on the exact transponder carrier assignment situation.
NOTE 3: The Bn is defined relative to the MES actual carrier frequency f
Bn is the width of the frequency interval (f -a, f +b), where a and bcan vary with f which are defined c c c for the intended use of the MES. The frequency interval (f -a, f +b) does not encompass more than c c either:
i) when a = b, 4 or less carrier frequencies for narrow-band systems; ii) when a ≠ b, 1 nominal carrier frequency for narrow-band systems; or iii) 1 nominal carrier frequency for wide-band systems.
The frequency interval (f -a, f +b) remains within the operational band of the MES. c c NOTE 4: Further explanation of nominated bandwidth is presented in annex B. operational band: sub-portion of the 1 610 MHz to 1 626,5 MHz band which has been assigned in the earth-to-space direction to the MSS network within which the MES is operating Portable Equipment (PE): generally intended to be self-contained, free standing and portable. A PE would normally consist of a single module, but can consist of several interconnected modules radiated measurement: measurement of an actual radiated field Special Test Equipment (STE): equipment which allows a test laboratory to control the MES so that the tests required by the present document can be performed test laboratory: laboratory which performs the conformance testing of the MES against the present document test load: test load is a substantially non-reactive, non-radiating power attenuator which is capable of safely dissipating the power from the transmitter(s) unwanted emissions: unwanted emissions are those falling outside the nominated bandwidth in the carrier-on state, and those generated in the carrier-off state ETSI
11 ETSI EN 301 441 V2.2.1 (2026-09)
wide-band system: wide-band system is one in which the nominal carrier frequency spacing for MESs in the Earth-to-Space direction is equal to or greater than 300 kHz
3.2 Symbols
Void.
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
AK-R Air Kerma Rate ASD Acceleration Spectral Density BE Lower Band Edge of the operating band L BE Upper Band Edge of the operating band U B Nominated Bandwidth n BW Bandwidth CDMA Code Division Multiple Access CMF Control and Monitoring Functions CW Continuous Wave dBW deciBels relative to 1 Watt EFTA European Free Trade Association EIRP Equivalent Isotropically Radiated Power EMC Electro-Magnetic Compatibility EME Externally Mounted Equipment EN European Standard ERM Electromagnetic compatibility and Radio spectrum Matters ETS European Telecommunication Standard EU European Union EUT Equipment Under Test IE Installable Equipment IEC International Electrotechnical Commission IME Internally Mounted Equipment ITU International Telecommunication Union ITU-T ITU Telecommunication Standardization Sector MES Mobile Earth Station MIC MES unique Identification Code (within its S-PCN) MSS Mobile Satellite Service OATS Open Area Test Site PCN Personal Communications Network PE Portable Equipment R&TTE Radio and Telecommunications Terminal Equipment RE Radio Equipment RED Radio Equipment Directive RF Radio Frequency SNR Signal to Noise Ratio S-PCN Satellite Personal Communications Network STE Special Test Equipment TBR Technical Basis for Regulation WRC World Radiocommunication Conference ZVEI Zentralverband Elektrotechnik- und Elektronik-industrie ETSI
12 ETSI EN 301 441 V2.2.1 (2026-09)
4 Technical requirements specifications
4.1 Environmental profile
4.1.1 General
The technical requirements of the present document apply under the environmental profile for operation of the equipment, which shall be in accordance with its intended use, but as a minimum, shall be that specified in the test conditions contained in the present document. The equipment shall comply with all the technical requirements of the present document at all times when operating within the boundary limits of the specified operational environmental profile defined by its intended use.
The environmental profile for operation of the equipment shall include the ranges of humidity, temperature and supply voltage.
4.1.2 Temperature
The MES shall fulfil all the requirements in the full temperature ranges of:
- -10 °C to +55 °C; taken from IEC publications 60068-2-1 [7] and 60068-2-2 [8].
4.1.3 Voltage
The nominal, lower and the higher extreme voltages shall be defined for the intended use of the MES and provided with the EUT documentation.
The MES shall fulfil all the requirements in the full voltage range between the extreme voltages.
4.2 Conformance requirements
4.2.1 Unwanted emissions outside the band 1 610 MHz to 1 626,5 MHz
and the band 1 626,5 MHz to 1 628,5 MHz (carrier-on)
4.2.1.1 Justification
Protection of other radio services operating outside the band 1 610 MHz to 1 628,5 MHz from emissions caused by S-PCN MESs operating within the band 1 610 MHz to 1 626,5 MHz.
4.2.1.2 Technical requirements
The maximum EIRP density of the unwanted emissions from the MES outside the band 1 610,0 MHz to 1 626,5 MHz and the band 1 626,5 MHz to 1 628,5 MHz shall not exceed the limits in table 3. In table 3, whenever a change of limit between adjacent frequency bands occurs, the lower of the two limits shall apply at the transition frequency.
ETSI
13 ETSI EN 301 441 V2.2.1 (2026-09)
Table 2: Void Table 3: Maximum unwanted emissions outside the band 1 610 MHz to 1 626,5 MHz and the band 1 626,5 MHz to 1 628,5 MHz Frequency Carrier-on (MHz) EIRP (dBW) Measurement bandwidth Measurement method 0,1 to 30 -66 10 kHz Peak-hold 30 to 1 000 -66 100 kHz Peak-hold 1 000 to 1 559 -60 1 MHz Average 1 559 to 1 580,42 -70 1 MHz Average (see note 1) 1 580,42 to 1 605 -70 1 MHz Average 1 605 to 1 610 -70 to -10 1 MHz Average (see note 2) 1 610 to 1 626,5 Not applicable Not applicable Not applicable 1 626,5 to 1 628,5 Not applicable Not applicable Not applicable 1 628,5 to 1 631,5 -60 30 kHz Average 1 631,5 to 1 636,5 -60 100 kHz Average 1 636,5 to 1 646,5 -60 300 kHz Average 1 646,5 to 1 666,5 -60 1 MHz Average 1 666,5 to 2 200 -60 3 MHz Average 2 200 to 12 750 -60 3 MHz Peak hold NOTE 1: In the sub-band 1 573,42 MHz to 1 580,42 MHz, the average measurement time is 20 ms. NOTE 2: Linearly interpolated in dBW vs. frequency offset.
The conformance requirements apply for the full range of environmental conditions corresponding to the type of equipment as specified in clause 4.1.
4.2.1.3 Conformance test
Conformance tests are described in clause 5.2.2.
4.2.2 Unwanted emissions within the band 1 610 MHz to 1 626,5 MHz and
the band 1 626,5 MHz to 1 628,5 MHz (carrier-on)
4.2.2.1 Justification
Protection of radio services and systems operating within the frequency band 1 610 to 1 628,5 MHz from unwanted emissions caused by S-PCN MESs operating in the band 1 610 MHz to 1 626,5 MHz.
4.2.2.2 Technical requirements
The maximum EIRP spectral density of the unwanted emissions from the MES within the band 1 610 MHz to 1 628,5 MHz shall not exceed the limits in tables 4, 5 or 6, as applicable. In tables 4, 5 and 6, whenever a change of limit between adjacent frequency bands occurs, the lower of the two limits shall apply at the transition frequency.
When conflicts between multiple requirements exist, the more stringent requirement applies. ETSI
14 ETSI EN 301 441 V2.2.1 (2026-09)
Table 4: Maximum unwanted emissions within the band 1 610,0 MHz to 1 626,5 MHz and the band 1 626,5 MHz to 1 628,5 MHz of MES operating such that the nominated bandwidth is entirely or partially contained in the frequency band 1 618,25 MHz to 1 626,5 MHz Carrier - on Frequency offset (kHz) EIRP (dBW) Measurement bandwidth (kHz) Measurement (see note 1) (see note 3) (see note 2) method 0 to 160 -35 30 Average 160 to 225 -35 to -38,5 30 Average 225 to 650 -38,5 to -45 30 Average 650 to 1 365 -45 30 Average 1 365 to 1 800 -53 to -56 30 Average 1 800 to 16 500 -56 30 Average NOTE 1: Frequency offset is determined from:
i) the nearest edge of the nominated bandwidth of the nominal carrier closest to the MSS system operating in another operational band within the band 1 610 MHz to 1 626,5 MHz. The frequency offset is measured in the direction of the adjacent MSS system; ii) the upper edge of the nominated bandwidth of the carrier under test for emissions within the band 1 626,5 MHz to 1 628,5 MHz.
NOTE 2: The measurement bandwidth used can be 3 kHz if the unwanted EIRP limits are reduced correspondingly.
NOTE 3: Linearly interpolated in dBW vs. frequency offset.
Table 5: Maximum unwanted emissions within the band 1 610,0 MHz to 1 626,5 MHz and the band 1626,5 MHz to 1628,5 MHz of MES operating such that the nominated bandwidth is entirely contained in the frequency band 1 610,0 MHz to 1 618,25 MHz Carrier - on Frequency offset (kHz) EIRP (dBW) Measurement bandwidth (kHz) Measurement method (see note 1) (see note 3) (see note 2) 0 to 160 -32 30 Average 160 to 2 300 -32 to -56 30 Average 2 300 to 18 500 -56 30 Average NOTE 1: Frequency offset is determined from:
i) the nearest edge of the nominated bandwidth of the nominal carrier closest to the MSS system operating in another operational band within the band 1 610 to 1 626,5 MHz The frequency offset is measured in the direction of the adjacent MSS system; ii) the upper edge of the nominated bandwidth of the carrier under test for emissions within the band 1 626,5 to 1 628,5 MHz.
NOTE 2: The measurement bandwidth used can be 3 kHz if the unwanted EIRP limits are reduced correspondingly.
NOTE 3: Linearly interpolated in dBW vs. frequency offset.
Table 6: Maximum unwanted emissions of MES carriers within the operational band of CDMA carriers Carrier - on Frequency offset (kHz) EIRP (dBW) Measurement bandwidth Measurement (see note 1) (see note 2) (kHz) method 0 to 70 -6 to -20 30 Average 70 to 600 -20 to -28 30 Average 600 to 2 000 -28 to -45 30 Average 2 000 to 5 000 -45 to -69 30 Average 5 000 to 16 500 -69 30 Average NOTE 1: Frequency offset is determined from edge of nominated bandwidth. NOTE 2: Linearly interpolated in dBW vs. frequency offset.
The conformance requirements apply for the full range of environmental conditions corresponding to the type of equipment as specified in clause 4.1.
ETSI
15 ETSI EN 301 441 V2.2.1 (2026-09)
4.2.2.3 Conformance test
Conformance tests are described in clause 5.2.3.
4.2.3 EIRP density within the operational band
4.2.3.1 Justification
To ensure that the maximum EIRP spectral density within the band 1 610 MHz to 1 626,5 MHz does not exceed the limits defined by the Final Acts of WRC-95 [6], S5.364.
4.2.3.2 Technical requirements
In any frequency sub-band of the band 1 610 MHz to 1 626,5 MHz, where the MES operates, one of the two following requirements shall apply under specific operating conditions:
a) The MES shall not produce a mean EIRP density exceeding -3 dB (W/4 kHz), (mean limit). NOTE: In this context, the mean is the mean over time whilst the MES is in the carrier-on mode. Or, b) The MES shall not produce a peak EIRP density exceeding -15 dB (W/4 kHz) (peak limit). The specific frequency sub-band(s) and operating conditions, for which the two different limits apply, shall be defined for the intended use of the MES and provided with the EUT documentation. These requirements apply to all types of MES, for every transmit channel of the MES in its operational band or sub-bands.
The conformance requirements apply for the full range of environmental conditions corresponding to the type of the equipment as described in clause 4.1.
4.2.3.3 Conformance test
Conformance tests are described in clause 5.2.4.
4.2.4 Unwanted emissions in carrier-off state
4.2.4.1 Justification
Protection of other radio services and systems from unwanted emissions caused by MESs in the carrier-off state.
4.2.4.2 Technical requirements
The maximum EIRP of the unwanted emissions from the MESs in the carrier-off state shall not exceed the limits in table 7.
In table 7, whenever a change of limit between adjacent frequency bands occurs, the lower of the two limits shall apply at the transition frequency.
...
Contents
- 1 Scope
- 2 References
- 2.1 Normative references
- 9 ETSI EN 301 441 V2.2.1 (2026-09)
- 2.2 Informative references
- 3 Definition of terms, symbols and abbreviations
- 3.1 Terms
- 10 ETSI EN 301 441 V2.2.1 (2026-09)
- 11 ETSI EN 301 441 V2.2.1 (2026-09)
- 3.2 Symbols
- 3.3 Abbreviations
- 12 ETSI EN 301 441 V2.2.1 (2026-09)
- 4 Technical requirements specifications
- 4.1 Environmental profile
- 4.2 Conformance requirements
- 13 ETSI EN 301 441 V2.2.1 (2026-09)
- 14 ETSI EN 301 441 V2.2.1 (2026-09)
- 15 ETSI EN 301 441 V2.2.1 (2026-09)
- 16 ETSI EN 301 441 V2.2.1 (2026-09)
- 17 ETSI EN 301 441 V2.2.1 (2026-09)
- 18 ETSI EN 301 441 V2.2.1 (2026-09)
- 19 ETSI EN 301 441 V2.2.1 (2026-09)
- 5 Testing for compliance with technical requirements
- 5.1 Environmental conditions for testing
- 20 ETSI EN 301 441 V2.2.1 (2026-09)
- 5.2 Essential radio test suites
- 21 ETSI EN 301 441 V2.2.1 (2026-09)
- 22 ETSI EN 301 441 V2.2.1 (2026-09)
- 23 ETSI EN 301 441 V2.2.1 (2026-09)
- 30 MHz to 12,75 GHz
- 24 ETSI EN 301 441 V2.2.1 (2026-09)
- 25 ETSI EN 301 441 V2.2.1 (2026-09)
- 26 ETSI EN 301 441 V2.2.1 (2026-09)
- 27 ETSI EN 301 441 V2.2.1 (2026-09)
- 28 ETSI EN 301 441 V2.2.1 (2026-09)
- 29 ETSI EN 301 441 V2.2.1 (2026-09)
- 30 ETSI EN 301 441 V2.2.1 (2026-09)
- 31 ETSI EN 301 441 V2.2.1 (2026-09)
- 32 ETSI EN 301 441 V2.2.1 (2026-09)
- 33 ETSI EN 301 441 V2.2.1 (2026-09)
- 34 ETSI EN 301 441 V2.2.1 (2026-09)
- 35 ETSI EN 301 441 V2.2.1 (2026-09)
- 36 ETSI EN 301 441 V2.2.1 (2026-09)
- 37 ETSI EN 301 441 V2.2.1 (2026-09)
- 38 ETSI EN 301 441 V2.2.1 (2026-09)
- 39 ETSI EN 301 441 V2.2.1 (2026-09)
- 1 Unwanted emissions outside the band
- 2 Unwanted emissions within the band 3.2 4.2.2 U
- 3 EIRP density within the operational band 3.2 4.2.3 U
- 4 Unwanted emissions in carrier-off state 3.2 4.2.4 U
- 5 Processor monitoring 3.2 The processor monitoring
- 6 Transmit frequency generation 3.2 Individual requirements for
- 7 Network control authorization 3.2 4.2.5.3 U
- 8 Transmission disable/ enable 3.2 4.2.5.4.1 U
- 9 Transmit frequency control 3.2 4.2.5.4.2 U
- 10 Fellow radio stations in a dual-mode or 3.2 4.2.5.5 U
- 11 Equipment identity 3.2 4.2.6 U
- 12 Protection of the radio astronomy service 3.2 4.2.7 U
- 40 ETSI EN 301 441 V2.2.1 (2026-09)
- 13 Receiver Adjacent Channel Selectivity 3.2 4.2.8 U
- 14 Receiver Blocking Characteristics 3.2 4.2.9 U
- 15 Receiver co-channel rejection 3.2 4.2.8 U
- 16 Single signal selectivity - receiver 3.2 4.2.8 U
- 20 Receiver multiple signal selectivity - 3.2 4.2.8 U
- 22 Reciprocal mixing 3.2 It is considered that the reciprocal
- 41 ETSI EN 301 441 V2.2.1 (2026-09)
- 42 ETSI EN 301 441 V2.2.1 (2026-09)
- 43 ETSI EN 301 441 V2.2.1 (2026-09)
- 44 ETSI EN 301 441 V2.2.1 (2026-09)
- 45 ETSI EN 301 441 V2.2.1 (2026-09)
- 46 ETSI EN 301 441 V2.2.1 (2026-09)
- 47 ETSI EN 301 441 V2.2.1 (2026-09)
- 48 ETSI EN 301 441 V2.2.1 (2026-09)
- 5 Hz to 20 Hz
- 20 Hz to 500 Hz
- 49 ETSI EN 301 441 V2.2.1 (2026-09)
- Bibliography
- 50 ETSI EN 301 441 V2.2.1 (2026-09)
- 51 ETSI EN 301 441 V2.2.1 (2026-09)
1 Scope
The present document applies to Mobile Earth Station (MES) radio equipment which have the following characteristics:
- the MES has both transmit and receive capabilities and operate in a Satellite-Personal Communications Network (S-PCN). An S-PCN MES can be a handheld, portable, vehicle-mounted, host connected, semi-fixed or fixed equipment, or can be an element in a multi-mode terminal. It consists of a number of modules with associated connections and user interface, or can be a self-contained single unit; - these MESs are controlled and monitored by Control Monitoring Functions (CMF). The CMF is outside the scope of the present document; - if the MES is an element in a multi-mode terminal, unless otherwise stated in the present document, its requirements apply only to the S-PCN MES element of the terminal operating in the MSS frequency bands given in table 1; - the MES is capable in operating in all or part of the frequency bands shown in table 1. Table 1: Mobile Satellite Service (MSS) frequency bands MES MSS frequency bands Transmit 1 610 MHz to 1 626,5 MHz Receive 1 613,8 MHz to 1 626,5 MHz Receive 2 483,5 MHz to 2 500,0 MHz
NOTE: The relationship between the present document and essential requirements of article 3.2 of Directive 2014/53/EU [i.3] is given in annex A.
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or nonspecific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found in the ETSI docbox.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long-term validity.
The following referenced documents are necessary for the application of the present document. [1] Void.
[2] Recommendation ITU-T O.153 (10/92): "Basic parameters for the measurement of error performance at bit rates below the primary rate".
[3] Void.
[4] Void.
[5] Void.
[6] Final Acts of the World Radiocommunication Conference (WRC '95); Geneva 1995. [7] IEC 60068-2-1 (2025): "Environmental testing - Part 2: Tests. Tests A: Cold". [8] IEC 60068-2-2 (2025): "Environmental testing - Part 2: Tests. Tests B: Dry heat". ETSI
SIST EN 301 441 V2.2.1:2026
9 ETSI EN 301 441 V2.2.1 (2026-09)
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long-term validity.
The following referenced documents may be useful in implementing an ETSI deliverable or add to the reader's understanding, but are not required for conformance to the present document. [i.1] Void.
[i.2] Commission Implementing Decision C(2015) 5376 final of 4.8.2015 on a standardisation request to the European Committee for Electrotechnical Standardisation and to the European Telecommunications Standards Institute as regards radio equipment in support of Directive 2014/53/EU of the European Parliament and of the Council.
[i.3] Directive 2014/53/EU of the European Parliament and of the Council of 16 April 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of radio equipment and repealing Directive 1999/5/EC.
[i.4] IEC 60068-2-64:2008+AMD1:2019 CSV: "Environmental testing. Part 2-64: Tests. Test Fh:
Vibration, broadband random and guidance".
3 Definition of terms, symbols and abbreviations
3.1 Terms
For the purposes of the present document, the following terms apply:
carrier-on state (allocated a channel): state in which the MES is transmitting a carrier carrier-off state (idle mode): radio state in which the MES does not actually transmit a carrier CMF control message: message, normally originating from a network, to a specified terminal or set of terminals of the network which indicates to the terminal or set of terminals that it/they carry out some specific action or enter or maintain some specific state NOTE: For test purposes CMF control messages can originate from CMF Simulator. conducted measurement: measurement of emissions from an antenna port of the MES made by direct wired connection to the port environmental profile: range of environmental conditions under which equipment within the scope of the present document is required to comply with the provisions of the present document Equivalent Isotropically Radiated Power (EIRP): product of transmitter power and maximum antenna gain, equivalent to an isotropic source radiating uniformly in all directions fellow radio station: another radio station operating in the same service, frequency band, or coordination environment as the station in question, such that it shares allocated spectrum with the mobile satellite earth terminal handheld: MES which is self-contained and is small enough and light enough to be carried and used during a call with one hand host-connected: MES for which connection to or integration with host equipment is necessary to offer functionality host equipment: any equipment which has a complete user functionality when not connected to the MES, and to which the MES provides additional functionality, and to which connection is necessary for the MES to offer functionality ETSI
SIST EN 301 441 V2.2.1:2026
10 ETSI EN 301 441 V2.2.1 (2026-09)
in-band signals: signals which are located in the operating band plus an offset of 10 MHz outside this operating band Installable Equipment (IE), Internally Mounted Equipment (IME) And Externally Mounted Equipment (EME):
Installable Equipment (IE) is an equipment which is intended to be installed in a vehicle NOTE: An IE consist of one or several interconnected modules. The IE is composed of modules intended to be externally mounted as defined for the intended use of the MES, and defined as Externally Mounted Equipment (EME) and the remaining modules(s) as Internally Mounted Equipment (IME). laboratory test equipment: logical grouping that contains the standard test equipment provided by a test laboratory MSS band: continuous range of frequencies allocated by the ITU to the MSS multi-mode: equipment that accommodates radio stations of different radio networks narrow-band system: narrow-band system is one in which the nominal carrier frequency spacing for MESs in the earth-to-space direction is less than 300 kHz network control channel: channel by which an MES receives general control information from the CMF(originated by a network control facility) of its S-PCN nominated bandwidth (Bn): Bandwidth of the Mobile Earth Station (MES) radio frequency transmission which is wide enough to encompass all spectral elements of the transmission NOTE 1: The nominated bandwidth is centred on the transmit frequency and does not exceed 5 times the occupied bandwidth.
NOTE 2: The nominated bandwidth is wide enough to take account of the transmit carrier frequency stability. This definition is chosen to allow flexibility regarding adjacent channel interference levels which will be taken into account by operational procedures depending on the exact transponder carrier assignment situation.
NOTE 3: The Bn is defined relative to the MES actual carrier frequency f
Bn is the width of the frequency interval (f -a, f +b), where a and bcan vary with f which are defined c c c for the intended use of the MES. The frequency interval (f -a, f +b) does not encompass more than c c either:
i) when a = b, 4 or less carrier frequencies for narrow-band systems; ii) when a ≠ b, 1 nominal carrier frequency for narrow-band systems; or iii) 1 nominal carrier frequency for wide-band systems.
The frequency interval (f -a, f +b) remains within the operational band of the MES. c c NOTE 4: Further explanation of nominated bandwidth is presented in annex B. operational band: sub-portion of the 1 610 MHz to 1 626,5 MHz band which has been assigned in the earth-to-space direction to the MSS network within which the MES is operating Portable Equipment (PE): generally intended to be self-contained, free standing and portable. A PE would normally consist of a single module, but can consist of several interconnected modules radiated measurement: measurement of an actual radiated field Special Test Equipment (STE): equipment which allows a test laboratory to control the MES so that the tests required by the present document can be performed test laboratory: laboratory which performs the conformance testing of the MES against the present document test load: test load is a substantially non-reactive, non-radiating power attenuator which is capable of safely dissipating the power from the transmitter(s) unwanted emissions: unwanted emissions are those falling outside the nominated bandwidth in the carrier-on state, and those generated in the carrier-off state ETSI
SIST EN 301 441 V2.2.1:2026
11 ETSI EN 301 441 V2.2.1 (2026-09)
wide-band system: wide-band system is one in which the nominal carrier frequency spacing for MESs in the Earth-to-Space direction is equal to or greater than 300 kHz
3.2 Symbols
Void.
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
AK-R Air Kerma Rate ASD Acceleration Spectral Density BE Lower Band Edge of the operating band L BE Upper Band Edge of the operating band U B Nominated Bandwidth n BW Bandwidth CDMA Code Division Multiple Access CMF Control and Monitoring Functions CW Continuous Wave dBW deciBels relative to 1 Watt EFTA European Free Trade Association EIRP Equivalent Isotropically Radiated Power EMC Electro-Magnetic Compatibility EME Externally Mounted Equipment EN European Standard ERM Electromagnetic compatibility and Radio spectrum Matters ETS European Telecommunication Standard EU European Union EUT Equipment Under Test IE Installable Equipment IEC International Electrotechnical Commission IME Internally Mounted Equipment ITU International Telecommunication Union ITU-T ITU Telecommunication Standardization Sector MES Mobile Earth Station MIC MES unique Identification Code (within its S-PCN) MSS Mobile Satellite Service OATS Open Area Test Site PCN Personal Communications Network PE Portable Equipment R&TTE Radio and Telecommunications Terminal Equipment RE Radio Equipment RED Radio Equipment Directive RF Radio Frequency SNR Signal to Noise Ratio S-PCN Satellite Personal Communications Network STE Special Test Equipment TBR Technical Basis for Regulation WRC World Radiocommunication Conference ZVEI Zentralverband Elektrotechnik- und Elektronik-industrie ETSI
SIST EN 301 441 V2.2.1:2026
12 ETSI EN 301 441 V2.2.1 (2026-09)
4 Technical requirements specifications
4.1 Environmental profile
4.1.1 General
The technical requirements of the present document apply under the environmental profile for operation of the equipment, which shall be in accordance with its intended use, but as a minimum, shall be that specified in the test conditions contained in the present document. The equipment shall comply with all the technical requirements of the present document at all times when operating within the boundary limits of the specified operational environmental profile defined by its intended use.
The environmental profile for operation of the equipment shall include the ranges of humidity, temperature and supply voltage.
4.1.2 Temperature
The MES shall fulfil all the requirements in the full temperature ranges of:
- -10 °C to +55 °C; taken from IEC publications 60068-2-1 [7] and 60068-2-2 [8].
4.1.3 Voltage
The nominal, lower and the higher extreme voltages shall be defined for the intended use of the MES and provided with the EUT documentation.
The MES shall fulfil all the requirements in the full voltage range between the extreme voltages.
4.2 Conformance requirements
4.2.1 Unwanted emissions outside the band 1 610 MHz to 1 626,5 MHz
and the band 1 626,5 MHz to 1 628,5 MHz (carrier-on)
4.2.1.1 Justification
Protection of other radio services operating outside the band 1 610 MHz to 1 628,5 MHz from emissions caused by S-PCN MESs operating within the band 1 610 MHz to 1 626,5 MHz.
4.2.1.2 Technical requirements
The maximum EIRP density of the unwanted emissions from the MES outside the band 1 610,0 MHz to 1 626,5 MHz and the band 1 626,5 MHz to 1 628,5 MHz shall not exceed the limits in table 3. In table 3, whenever a change of limit between adjacent frequency bands occurs, the lower of the two limits shall apply at the transition frequency.
ETSI
SIST EN 301 441 V2.2.1:2026
13 ETSI EN 301 441 V2.2.1 (2026-09)
Table 2: Void Table 3: Maximum unwanted emissions outside the band 1 610 MHz to 1 626,5 MHz and the band 1 626,5 MHz to 1 628,5 MHz Frequency Carrier-on (MHz) EIRP (dBW) Measurement bandwidth Measurement method 0,1 to 30 -66 10 kHz Peak-hold 30 to 1 000 -66 100 kHz Peak-hold 1 000 to 1 559 -60 1 MHz Average 1 559 to 1 580,42 -70 1 MHz Average (see note 1) 1 580,42 to 1 605 -70 1 MHz Average 1 605 to 1 610 -70 to -10 1 MHz Average (see note 2) 1 610 to 1 626,5 Not applicable Not applicable Not applicable 1 626,5 to 1 628,5 Not applicable Not applicable Not applicable 1 628,5 to 1 631,5 -60 30 kHz Average 1 631,5 to 1 636,5 -60 100 kHz Average 1 636,5 to 1 646,5 -60 300 kHz Average 1 646,5 to 1 666,5 -60 1 MHz Average 1 666,5 to 2 200 -60 3 MHz Average 2 200 to 12 750 -60 3 MHz Peak hold NOTE 1: In the sub-band 1 573,42 MHz to 1 580,42 MHz, the average measurement time is 20 ms. NOTE 2: Linearly interpolated in dBW vs. frequency offset.
The conformance requirements apply for the full range of environmental conditions corresponding to the type of equipment as specified in clause 4.1.
4.2.1.3 Conformance test
Conformance tests are described in clause 5.2.2.
4.2.2 Unwanted emissions within the band 1 610 MHz to 1 626,5 MHz and
the band 1 626,5 MHz to 1 628,5 MHz (carrier-on)
4.2.2.1 Justification
Protection of radio services and systems operating within the frequency band 1 610 to 1 628,5 MHz from unwanted emissions caused by S-PCN MESs operating in the band 1 610 MHz to 1 626,5 MHz.
4.2.2.2 Technical requirements
The maximum EIRP spectral density of the unwanted emissions from the MES within the band 1 610 MHz to 1 628,5 MHz shall not exceed the limits in tables 4, 5 or 6, as applicable. In tables 4, 5 and 6, whenever a change of limit between adjacent frequency bands occurs, the lower of the two limits shall apply at the transition frequency.
When conflicts between multiple requirements exist, the more stringent requirement applies. ETSI
SIST EN 301 441 V2.2.1:2026
14 ETSI EN 301 441 V2.2.1 (2026-09)
Table 4: Maximum unwanted emissions within the band 1 610,0 MHz to 1 626,5 MHz and the band 1 626,5 MHz to 1 628,5 MHz of MES operating such that the nominated bandwidth is entirely or partially contained in the frequency band 1 618,25 MHz to 1 626,5 MHz Carrier - on Frequency offset (kHz) EIRP (dBW) Measurement bandwidth (kHz) Measurement (see note 1) (see note 3) (see note 2) method 0 to 160 -35 30 Average 160 to 225 -35 to -38,5 30 Average 225 to 650 -38,5 to -45 30 Average 650 to 1 365 -45 30 Average 1 365 to 1 800 -53 to -56 30 Average 1 800 to 16 500 -56 30 Average NOTE 1: Frequency offset is determined from:
i) the nearest edge of the nominated bandwidth of the nominal carrier closest to the MSS system operating in another operational band within the band 1 610 MHz to 1 626,5 MHz. The frequency offset is measured in the direction of the adjacent MSS system; ii) the upper edge of the nominated bandwidth of the carrier under test for emissions within the band 1 626,5 MHz to 1 628,5 MHz.
NOTE 2: The measurement bandwidth used can be 3 kHz if the unwanted EIRP limits are reduced correspondingly.
NOTE 3: Linearly interpolated in dBW vs. frequency offset.
Table 5: Maximum unwanted emissions within the band 1 610,0 MHz to 1 626,5 MHz and the band 1626,5 MHz to 1628,5 MHz of MES operating such that the nominated bandwidth is entirely contained in the frequency band 1 610,0 MHz to 1 618,25 MHz Carrier - on Frequency offset (kHz) EIRP (dBW) Measurement bandwidth (kHz) Measurement method (see note 1) (see note 3) (see note 2) 0 to 160 -32 30 Average 160 to 2 300 -32 to -56 30 Average 2 300 to 18 500 -56 30 Average NOTE 1: Frequency offset is determined from:
i) the nearest edge of the nominated bandwidth of the nominal carrier closest to the MSS system operating in another operational band within the band 1 610 to 1 626,5 MHz The frequency offset is measured in the direction of the adjacent MSS system; ii) the upper edge of the nominated bandwidth of the carrier under test for emissions within the band 1 626,5 to 1 628,5 MHz.
NOTE 2: The measurement bandwidth used can be 3 kHz if the unwanted EIRP limits are reduced correspondingly.
NOTE 3: Linearly interpolated in dBW vs. frequency offset.
Table 6: Maximum unwanted emissions of MES carriers within the operational band of CDMA carriers Carrier - on Frequency offset (kHz) EIRP (dBW) Measurement bandwidth Measurement (see note 1) (see note 2) (kHz) method 0 to 70 -6 to -20 30 Average 70 to 600 -20 to -28 30 Average 600 to 2 000 -28 to -45 30 Average 2 000 to 5 000 -45 to -69 30 Average 5 000 to 16 500 -69 30 Average NOTE 1: Frequency offset is determined from edge of nominated bandwidth. NOTE 2: Linearly interpolated in dBW vs. frequency offset.
The conformance requirements apply for the full range of environmental conditions corresponding to the type of equipment as specified in clause 4.1.
ETSI
SIST EN 301 441 V2.2.1:2026
15 ETSI EN 301 441 V2.2.1 (2026-09)
4.2.2.3 Conformance test
Conformance tests are described in clause 5.2.3.
4.2.3 EIRP density within the operational band
4.2.3.1 Justification
To ensure that the maximum EIRP spectral density within the band 1 610 MHz to 1 626,5 MHz does not exceed the limits defined by the Final Acts of WRC-95 [6], S5.364.
4.2.3.2 Technical requirements
In any frequency sub-band of the band 1 610 MHz to 1 626,5 MHz, where the MES operates, one of the two following requirements shall apply under specific operating conditions:
a) The MES shall not produce a mean EIRP density exceeding -3 dB (W/4 kHz), (mean limit). NOTE: In this context, the mean is the mean over time whilst the MES is in the carrier-on mode. Or, b) The MES shall not produce a peak EIRP density exceeding -15 dB (W/4 kHz) (peak limit). The specific frequency sub-band(s) and operating conditions, for which the two different limits apply, shall be defined for the intended use of the MES and provided with the EUT documentation. These requirements apply to all types of MES, for every transmit channel of the MES in its operational band or sub-bands.
The conformance requirements apply for the full range of environmental conditions corresponding to the type of the equipment as described in clause 4.1.
4.2.3.3 Conformance test
Conformance tests are described in clause 5.2.4.
4.2.4 Unwanted emissions in carrier-off state
4.2.4.1 Justification
Protection of other radio services and systems from unwanted emissions caused by MESs in the carrier-off state.
4.2.4.2 Technical requirements
The maximum EIRP of the unwanted emissions from the MESs in the carrier-off state shall not exceed the limits in table 7.
In table 7, whenever a change of limit between adjacent frequency bands occurs, the lower of the two limits shall apply at the transition frequency.
...