SIST EN 60933-5:1999
(Main)Audio, video and audiovisual systems - Interconnections and matching values -- Part 5: Y/C connector for video systems - Electrical matching values and description of the connector
- Abstract
Applies to the transfer of video signals between two pieces of equipment in an NTSC, PAL or SECAM high-resolution video system, in the form of a Y-signal, consisting of luminance + blanking + sync, and a C-signal, the same as the modulated chrominance signal of the composite video signal. It specifies the signal levels and impedances at the interface and the type of connector to be used.
- Status
- Published
- Publication Date
- 31-Mar-1999
- Technical Committee
- AVM - Audio, video and multimedia systems and equipment
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Apr-1999
- Due Date
- 01-Apr-1999
- Completion Date
- 01-Apr-1999
SIST EN 60933-5:1999 is a SIST adoption of the IEC/EN standard for the Y/C connector used in video systems. It specifies the electrical matching values and the connector description for transfer of video signals between two pieces of equipment in NTSC, PAL or SECAM high-resolution colour video systems. In practice, it tells equipment makers and integrators what signal levels, impedances and connector arrangement to use at the interface.
What does SIST EN 60933-5:1999 specify?
SIST EN 60933-5:1999 applies to the transfer of video signals between two pieces of equipment in an NTSC, PAL or SECAM high-resolution video system. The standard focuses on the Y signal, which carries luminance plus blanking plus sync, and the C signal, which is the modulated chrominance signal of the composite video signal.
It specifies the signal levels and impedances at the interface, and it identifies the connector type to be used. The document is organized into a short scope, one normative reference, the main requirements in Clause 3, and an informative annex with connector drawings.
| Part of the document | What it covers |
|---|---|
| Clause 1 | Scope of the standard |
| Clause 2 | Normative reference |
| Clause 3 | Contact designation, matching values, and connector requirements |
| Annex A | Type of connector, with plug and socket figures |
What are the key requirements of SIST EN 60933-5:1999?
SIST EN 60933-5:1999 defines how the contacts are designated and what electrical conditions the Y/C interface must meet. For users, this means the connector, signal polarity and matching values must be aligned so that video equipment can interconnect without ambiguity.
Contact designation and function
Clause 3.1 and 3.2 assign the contacts and their functions. The table gives separate returns for Y and C, a Y input or output signal contact, and the screen connection.
In practice, this matters because designers must wire the connector consistently on both equipment and cable ends. Wrong contact assignment can break picture transmission or create interference between luminance and chrominance paths.
Y and C signal matching
Clause 3.2 gives the matching values for the Y and C signals. The Y signal is specified at 1,0 Vpp with a rated input impedance of 75 Ω, and the C signal is specified relative to the standard chrominance level for the same Y signal level, with a rated input or output impedance of 75 Ω.
For users, this means the interface is tied to a defined video level and a defined load. Equipment designers and test labs can use these values to check that source and load equipment will interoperate correctly.
Synchronization and timing
The notes in Clause 3.2 state that synchronization polarity shall be negative. For PAL, the Y and C signals shall be time coincident within 100 ns, measured at the output of the source equipment using a standard colour bar signal at the green/magenta transition.
This matters in practice because timing between luminance and chrominance affects picture quality. The note gives a specific way to check coincidence, so manufacturers know how to verify alignment during design or testing.
PAL chroma amplitude balance
The PAL note also requires the green and magenta chroma signal amplitudes to be equal within 10%.
For readers, this is a practical check on signal balance in PAL operation. It helps maintain consistent colour reproduction at the interface.
Connector construction
Clause 3.3 says the electrical and mechanical requirements of the connector are in accordance with a future IEC standard under consideration. Annex A describes the connector as a circular type with four contacts and shows the plug and socket, with equipment using a socket with female contacts and cables using a plug with male contacts at each end.
This means the document gives the interface intent and form factor, while leaving the detailed connector standardization to a future IEC document.
What terms does SIST EN 60933-5:1999 define?
- Y signal - The luminance path, including blanking and sync, used to carry the brightness-related part of the video signal.
- C signal - The chrominance path carrying the modulated colour information.
- Y/C connector - The connector arrangement used to transfer Y and C separately between video equipment.
- NTSC - One of the television system formats named in the scope for which the interface applies.
- PAL - One of the television system formats named in the scope, also used in the timing and amplitude note.
- SECAM - One of the television system formats named in the scope for which the interface applies.
- CCIR Report 624-3 - The normative television-system reference used for the standard chrominance level.
Who uses SIST EN 60933-5:1999?
SIST EN 60933-5:1999 is used by designers and manufacturers of audio, video and audiovisual equipment, especially equipment for high-resolution colour video systems. It is also relevant to connector and cable designers, test laboratories, and engineers who specify or verify video interfaces.
Buyers and quality managers use it when they need to check whether equipment has the correct Y/C interface and matching values. System integrators use it when connecting source and destination equipment in NTSC, PAL or SECAM environments.
Which standards are used with SIST EN 60933-5:1999?
The normative reference named in Clause 2 is CCIR Report 624-3:1986, Characteristics of television systems - Recommendations and reports of the CCIR. The standard uses it for the definition of the standard chrominance level referenced in the C-signal matching values.
What does the SIST EN 60933-5:1999 document contain?
The document contains a scope statement, one normative reference, a requirements clause, one table of contact designation and matching values, two figures, and an informative annex. Table 1 gives the contact functions and electrical values, while Figure 1 shows the contact designation and Figure 2 shows chrominance-luminance time coincidence for PAL.
Annex A gives the connector type in drawing form, including the plug and socket, and identifies it as a circular connector with four contacts. The document is therefore useful both for interface specification and for verifying practical connector implementation in design, testing, and equipment matching.
Relations
- Effective Date
- 03-Feb-2026
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 60933-5:1999 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Audio, video and audiovisual systems - Interconnections and matching values -- Part 5: Y/C connector for video systems - Electrical matching values and description of the connector". This standard covers: Applies to the transfer of video signals between two pieces of equipment in an NTSC, PAL or SECAM high-resolution video system, in the form of a Y-signal, consisting of luminance + blanking + sync, and a C-signal, the same as the modulated chrominance signal of the composite video signal. It specifies the signal levels and impedances at the interface and the type of connector to be used.
Applies to the transfer of video signals between two pieces of equipment in an NTSC, PAL or SECAM high-resolution video system, in the form of a Y-signal, consisting of luminance + blanking + sync, and a C-signal, the same as the modulated chrominance signal of the composite video signal. It specifies the signal levels and impedances at the interface and the type of connector to be used.
SIST EN 60933-5:1999 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors; 33.160.01 - Audio, video and audiovisual systems in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 60933-5:1999 has the following relationships with other standards: It is inter standard links to SIST EN 60107-1:1999. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 60933-5:1999 is associated with the following European legislation: Standardization Mandates: BC-IT-80 EFTA-IT-80. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 60933-5:1999 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative reference
- 3 Requirements
- 3.1 Contact designation
- 1 Return for Y signal -
- 2 Return for C signal -
- 3 Y input or output signal - Input or output voltge: 1,0 V ± 3 dB (PAL/SECAM/NTSC)
- 5 Screen of plug No connection or connected to cable screen
- 2 For PAL
- 3.3 Electrical and mechanical requirements of the connector
- Annex A
1 Scope
This International Standard applies to the transfer of video signals between two pieces of high-resolution colour video system, in the form of equipment in an NTSC, PAL or SECAM a Y-signal, consisting of luminance + blanking + sync, and a C-signal, the same as the signal of the composite video signal. It specifies the signal levels modulated chrominance and impedances at the interface and the type of connector to be used.
2 Normative reference
The following normative document contains provisions which, through reference in this text, constitutes provisions of this International Standard. At the time of publication, the rties edition indicated was valid. All normative documents are subject to revision, and pa to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent edition of the normative document indicated below. Members of lEC and ISO maintain registers of currently valid International Standards. Characteristics of television systems - Recommendations and 624-3, 1986:
CCIR Report 1986, Vol. XI-1.
reports of the CCIR,
...