Abstract

This documents deals with the safety of electric multifunctional shower cabinets and electric separate multifunctional shower units for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances including DC supplied appliances.
Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in hotels, fitness centres and similar locations, are within the scope of this standard.
As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home.

Status
Not Published
Public Enquiry End Date
30-Dec-2026
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
03-Nov-2026
Due Date
23-Mar-2027

Buy Documents

Draft

oSIST prEN IEC 60335-2-105:2026

English language (22 pages)
Preview
Preview
e-Library read for
×1 day

oSIST prEN IEC 60335-2-105:2026 is a draft European standard published by SIST for the safety of electric multifunctional shower cabinets and electric separate multifunctional shower units. It sets particular safety requirements for household and similar appliances, including units used by laypersons in hotels, fitness centres and similar locations, within the stated voltage limits.

What does oSIST prEN IEC 60335-2-105:2026 specify?

oSIST prEN IEC 60335-2-105:2026 specifies the safety requirements for electric multifunctional shower cabinets and separate multifunctional shower units. The standard is built as a Part 2 document, so it supplements and modifies the general safety rules of the IEC 60335 series rather than repeating them.

The scope covers appliances for household and similar use with rated voltage not more than 250 V for single-phase appliances and 480 V for other appliances, including DC supplied appliances. It also covers appliances that are not intended for normal household use but can still present a risk to the public, such as units used by laymen in hotels and fitness centres.

The document follows the usual IEC 60335 structure: scope, normative references, terms and definitions, general requirements, test conditions, classification, marking and instructions, protection against access to live parts, heating, moisture resistance, abnormal operation, construction, and annexes.

AnnexWhat it covers
Annex RSoftware evaluation
Annex AAExample of a multifunctional shower cabinet
Annex BBExample of a separate multifunctional shower unit

What are the key requirements of oSIST prEN IEC 60335-2-105:2026?

oSIST prEN IEC 60335-2-105:2026 focuses on practical safety issues that matter in installation, testing and everyday use. The most important requirements are about combined functions, ingress protection, warnings, temperature limits, electrical protection, steam and pressure safety, and software-controlled operation.

  • Clause 5.4 requires test engineers to consider the influence of another function that may operate at the same time. In practice, the appliance is not assessed as isolated sub-functions - simultaneous use must be taken into account.

  • Clause 6.2 requires multifunctional shower cabinets and separate multifunctional shower units to be at least IPX4. This means the enclosure has to provide a defined level of protection against splashing water, which is directly relevant in a wet bathroom environment.

  • Clause 7 adds marking and instruction requirements for air-heating, lamps, hot surfaces, hygiene, child use, and installation. The appliance may need a “Do not cover” warning, a lamp power marking, and a hot-surface warning when outlet temperatures exceed the stated limit. The instructions also have to cover cleaning for hygienic conditions and warn that separate electrical steam- or humidity-producing appliances are not to be used inside the cabinet.

  • Clause 7.12.1 links the product to national wiring rules. It states that earthed appliances must be permanently connected to fixed wiring, that the appliance should be supplied through a residual current device (RCD) not exceeding 30 mA, and that the installation must follow the correct zone and equipotential bonding rules. In practice, this affects how installers wire and position the appliance.

  • Clause 8.1.4 treats energized parts as live parts, with limited exceptions for certain water level sensors at safety extra-low voltage not exceeding 12 V, within an earthed metal enclosure, and in permanently connected appliances. This matters because it sets the electrical shock protection approach for internal components.

  • Clause 11 and Table 101 set temperature-rise limits for air outlets and specified accessible surfaces inside the shower cabinet. The document also requires combined appliances to be operated as heating appliances and requires steady conditions before the limits are checked. For users and designers, this is the section that governs whether surfaces can become too hot to touch.

  • Clause 15 adds moisture-resistance measures, including the IEC 60529 test for the inside of the shower cabinet. Traces of water on insulation in components operating at safety extra-low voltage not exceeding 12 V are ignored, which focuses the test on meaningful electrical risk.

  • Clause 19 and Clause 22 address abnormal operation and construction. Steam bath functions are tested without water supply, fan-equipped appliances are tested with the motor stopped under the stated condition, and appliances with air heating receive an additional thermal test. Clause 22 also requires safeguards against excessive pressure in steam-bath appliances, limits user-accessible switches and controls to safety extra-low voltage not exceeding 12 V, limits remaining recirculated water to 0,15 l, and requires steam outlets not to direct steam towards the user.

  • Clause 22.103, Annex R and Clause 30.101 cover programmable electronics and fire resistance. If software limits how many heaters and motors can run together, the appliance must remain safe when those limits are bypassed or when fault conditions are applied. Air heaters with substantially non-metallic enclosures must also withstand the needle-flame test, unless the material classification condition stated in the document applies.

What terms does oSIST prEN IEC 60335-2-105:2026 define?

  • Multifunctional shower cabinet - a prefabricated shower cabinet that includes at least one additional function, such as a steam bath, besides the showering function.

  • Separate multifunctional shower unit - a multifunctional shower unit without a prefabricated shower cabinet that includes at least one electric function in addition to showering.

  • Residual current device (RCD) - a protective device mentioned in the installation instructions for supplying the appliance, used here to reduce electric shock risk.

  • IPX4 - the minimum ingress protection level required for the appliance enclosure, indicating protection against splashing water.

  • Safety extra-low voltage - the low-voltage level used in several safety provisions for sensors, switches, controls and other parts inside the appliance.

  • Equipotential bonding - the connection required by the instructions and terminal provisions so exposed conductive parts can be brought to the same electrical potential.

  • Programmable electronic circuits - control circuits whose software and safety-related hardware are evaluated in Annex R when they limit heater and motor operation.

Who uses oSIST prEN IEC 60335-2-105:2026?

Manufacturers of multifunctional shower cabinets and separate multifunctional shower units use this standard when designing products, selecting components and writing instructions. Electrical safety engineers and test laboratories use it for type testing, temperature-rise checks, moisture tests, abnormal-operation tests and software evaluation.

Certification bodies and conformity assessment teams use it to judge whether a product follows the Part 2-105 safety rules together with IEC 60335-1. Installers, quality managers and buyers use it to check wiring, marking, installation conditions and the practical safety points that matter in hotels, fitness centres and similar installations.

What changed in oSIST prEN IEC 60335-2-105:2026 from the previous edition?

oSIST prEN IEC 60335-2-105:2026 supersedes EN IEC 60335-2-105:2021 and its listed amendment and corrigendum versions. The document states three main technical changes:

  • alignment with IEC 60335-1:2020;
  • conversion of some notes into normative text in Clause 1;
  • updated surface temperature requirements in 11.8 and Table 101.

Which standards are used with oSIST prEN IEC 60335-2-105:2026?

  • IEC 60335-1 - the base Part 1 standard that supplies the general safety rules this Part 2 modifies and supplements.
  • prEN IEC 60335-2-105:2026/prAA:2026 - the draft is read in conjunction with this companion amendment text.
  • IEC 60529:1989 - provides the water-ingress test used for the inside of the shower cabinet.
  • IEC 60417 - provides the symbols used for “hot surface” and “do not cover” markings.
  • IEC 60364 - supplies the wiring-rule context referenced in the installation instructions.
  • IEC 60695-11-10 - provides the flammability classification referenced for the needle-flame test exemption.
  • IEC 60335-2-35 and IEC 60335-2-41 - identify appliances excluded from the scope as separate product types.
  • IEC 62368 (all parts) and the IEC 60598 series - are referenced when the appliance includes parts that fall within those standards’ scope.

What does the oSIST prEN IEC 60335-2-105:2026 document contain?

The document contains the clause-by-clause safety requirements for multifunctional shower cabinets and separate multifunctional shower units, including electrical protection, heating, moisture, abnormal operation and construction provisions. It also contains Table 101 for temperature-rise limits inside the shower cabinet.

Annex R gives the software-evaluation method for programmable electronic circuits and the fault or error conditions they must withstand. Annex AA and Annex BB provide example figures of a multifunctional shower cabinet and a separate multifunctional shower unit, which helps readers understand the product forms covered by the standard.

The document also includes a pressure-safeguard test for steam-bath appliances, the IEC 60529 moisture test applied to the cabinet interior, and the needle-flame test for non-metallic air-heater enclosures. These are the parts most directly used in design verification, safety testing and certification review.

Relations

Effective Date
28-Apr-2026
Effective Date
28-Apr-2026
Effective Date
28-Apr-2026
Effective Date
28-Apr-2026

Buy Documents

Draft

oSIST prEN IEC 60335-2-105:2026

English language (22 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Kiwa BDA Testing

Building and construction product certification.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

oSIST prEN IEC 60335-2-105:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Household and similar electrical appliances - Safety - Part 2-105: Particular requirements for multifunctional shower cabinets". This standard covers: This documents deals with the safety of electric multifunctional shower cabinets and electric separate multifunctional shower units for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances including DC supplied appliances. Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in hotels, fitness centres and similar locations, are within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home.

This documents deals with the safety of electric multifunctional shower cabinets and electric separate multifunctional shower units for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances including DC supplied appliances. Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in hotels, fitness centres and similar locations, are within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home.

oSIST prEN IEC 60335-2-105:2026 is classified under the following ICS (International Classification for Standards) categories: 13.120 - Domestic safety; 91.140.70 - Sanitary installations; 97.170 - Body care equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

oSIST prEN IEC 60335-2-105:2026 has the following relationships with other standards: It is inter standard links to oSIST prEN IEC 60335-2-105:2026/oprAA:2026, SIST EN IEC 60335-2-105:2022, SIST EN IEC 60335-2-105:2022/A1:2022, SIST EN IEC 60335-2-105:2022/A11:2022. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

oSIST prEN IEC 60335-2-105:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/35/EU, 2014/53/EU; Standardization Mandates: M/511, M/536. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

oSIST prEN IEC 60335-2-105:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.5 Definitions relating to types of appliances
  • 4 General requirement
  • 5 General conditions for the tests
  • 6 Classification
  • 7 Marking and instructions
  • 8 Protection against access to live parts
  • 9 Starting of motor-operated appliances
  • 10 Power input and current
  • 11 Heating
  • 12 Charging of metal-ion batteries
  • 13 Leakage current and electric strength at operating temperature
  • 14 Transient overvoltages
  • 15 Moisture resistance
  • 16 Leakage current and electric strength
  • 17 Overload protection of transformers and associated circuits
  • 18 Endurance
  • 19 Abnormal operation
  • 20 Stability and mechanical hazards
  • 21 Mechanical strength
  • 22 Construction
  • 23 Internal wiring
  • 24 Components
  • 25 Supply connection and external flexible cords
  • 26 Terminals for external conductors
  • 27 Provision for earthing
  • 28 Screws and connections
  • 29 Clearances, creepage distances and solid insulation
  • 30 Resistance to heat and fire
  • 31 Resistance to rusting
  • 32 Radiation, toxicity and similar hazards
  • Annex R
  • Annex AA
  • Annex BB
  • Bibliography

INTRODUCTION It has been assumed in the drafting of this International Standard that the execution of its provisions is entrusted to appropriately qualified and experienced persons. Guidance documents concerning the application of the safety requirements for appliances can be accessed via TC 61 supporting documents on the IEC website https://www.iec.ch/tc61/supportingdocuments This information is given for the convenience of users of this International Standard and does not constitute a replacement for the normative text in this standard. This standard recognizes the internationally accepted level of protection against hazards such as electrical, mechanical, thermal, fire and radiation of appliances when operated as in normal use taking into account the manufacturer's instructions. It also covers abnormal situations that can be expected in practice and takes into account the way in which electromagnetic phenomena can affect the safe operation of appliances.

This standard takes into account the requirements of IEC 60364 as far as possible so that there is compatibility with the wiring rules when the appliance is connected to the supply mains. However, national wiring rules can differ.

If an appliance within the scope of this standard also incorporates functions that are covered by another part 2 of IEC 60335, the relevant part 2 is applied to each function separately, as far as is reasonable. If applicable, the influence of one function on the other is taken into account.

When a part 2 standard does not include additional requirements to cover hazards dealt with in Part 1, Part 1 applies.

NOTE 1 This means that the technical committees responsible for the part 2 standards have determined that it is not necessary to specify particular requirements for the appliance in question over and above the general requirements.

This standard is a product family standard dealing with the safety of appliances and takes precedence over horizontal and generic standards covering the same subject. NOTE 2 Horizontal publications, basic safety publications and group safety publications covering a hazard are not applicable since they have been taken into consideration when developing the general and particular requirements for the IEC 60335 series of standards.

An appliance that complies with the text of this standard will not necessarily be considered to comply with the safety principles of the standard if, when examined and tested, it is found to have other features that impair the level of safety covered by these requirements. An appliance employing materials or having forms of construction differing from those detailed in the requirements of this standard may be examined and tested according to the intent of the requirements and, if found to be substantially equivalent, may be considered to comply with the standard.

NOTE 3 Standards dealing with non-safety aspects of household appliances are:

  • IEC standards published by TC 59 concerning methods of measuring performance;
  • CISPR 11, CISPR 14-1 and relevant IEC 61000-3 series standards concerning electromagnetic emissions;
  • CISPR 14-2 concerning electromagnetic immunity;
  • IEC standards published by TC 111 concerning environmental matters.

oSIST prEN IEC 60335-2-105:2026

1 Scope

This clause of Part 1 is replaced by the following.

This part of IEC 60335 deals with the safety of electric multifunctional shower cabinets and electric separate multifunctional shower units for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances including DC supplied appliances.

Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in hotels, fitness centres and similar locations, are within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account - persons (including children) whose - physical, sensory or mental capabilities; or - lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction; - children playing with the appliance.

Attention is drawn to the fact that - for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary; - in many countries, additional requirements are specified by the national health authorities, the national water supply authorities, the national authorities responsible for the protection of labour and similar authorities; - in many countries, mechanical strength, impact resistance and shattering properties of shower enclosures can be covered by national regulations.

If an appliance incorporates a part that is within the scope of IEC 60598 series or IEC 62368 series, the part is tested in accordance with the relevant standard as far as reasonable. This standard does not apply to - instantaneous water heaters used for showering (IEC 60335-2-35); - shower-boost pumps (IEC 60335-2-41); - appliances intended for medical purposes; - appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas).

2 Normative references

This clause of Part 1 is applicable.

oSIST prEN IEC 60335-2-105:2026

3 Terms and definitions

This clause of Part 1 is applicable except as follows.

3.5 Definitions relating to types of appliances

3.5.101 multifunctional shower cabinet prefabricated shower cabinet that incorporates at least one other function, such as a steam bath, in addition to the showering function Note 1 to entry: An example of a multifunctional shower cabinet is shown in informative Annex AA. 3.5.102 separate multifunctional shower unit multifunctional shower unit without a prefabricated shower cabinet that incorporates at least one electric function in addition to the showering function Note 1 to entry: An example of a separate multifunctional shower unit is shown in informative Annex BB.

4 General requirement

This clause of Part 1 is applicable.

5 General conditions for the tests

This clause of Part 1 is applicable except as follows.

5.4 Addition:

When testing a function of the appliance, the influence of another function that can be applied simultaneously is taken into account.

5.6 Addition:

Sensing elements located in the air intake to the heater are short-circuited or otherwise rendered inoperative.

6 Classification

This clause of Part 1 is applicable except as follows.

6.2 Addition:

Multifunctional shower cabinets and separate multifunctional shower units shall be at least IPX4.

oSIST prEN IEC 60335-2-105:2026

7 Marking and instructions

This clause of Part 1 is applicable except as follows.

7.1 Addition:

Appliances with an air-heating function, other than those having the air outlet located at a height at least 1,8 m above the floor or those that cannot be covered, shall be marked near the air outlet with symbol IEC 60417-6096 (2012-01) or with the substance of the following:

WARNING: Do not cover Appliances shall be marked on or near the lampholder with the maximum power input of replaceable lamps as follows:

...