prEN IEC 60335-2-105:2026
(Main)Household and similar electrical appliances - Safety - Part 2-105: Particular requirements for multifunctional shower cabinets
- Abstract
This documents deals with the safety of electric multifunctional shower cabinets and electric separate multifunctional shower units for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances including DC supplied appliances. Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in hotels, fitness centres and similar locations, are within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home.
- Status
- Not Published
- Publication Date
- 10-Oct-2028
- Technical Committee
- CLC/TC 61 - Safety of household and similar electrical appliances
- Current Stage
- 4020 - Enquiry circulated - Enquiry
- Start Date
- 23-Oct-2026
- Due Date
- 23-Oct-2026
- Completion Date
- 23-Oct-2026
prEN IEC 60335-2-105:2026 is a CENELEC draft European standard for the safety of electric multifunctional shower cabinets and electric separate multifunctional shower units. It covers household and similar appliances, including units used by laymen in places such as hotels and fitness centres, and it sets particular safety requirements for the equipment and for the way it is marked, installed, tested, and constructed.
What does prEN IEC 60335-2-105:2026 specify?
prEN IEC 60335-2-105:2026 specifies particular safety requirements for electric multifunctional shower cabinets and electric separate multifunctional shower units within the IEC 60335 family. It is used with IEC 60335-1 and modifies or supplements the general requirements in that standard for this appliance type.
The scope covers appliances with rated voltage not more than 250 V for single-phase appliances and 480 V for other appliances, including DC supplied appliances. It also includes appliances not intended for normal household use when they can still present danger to the public.
The document is organized into Clauses 1 to 32, with additional annexes. Annex R is normative and covers software evaluation, while Annex AA and Annex BB are informative examples.
| Annex | What it covers |
|---|---|
| Annex R | Software evaluation |
| Annex AA | Example of a multifunctional shower cabinet |
| Annex BB | Example of a separate multifunctional shower unit |
The standard excludes instantaneous water heaters used for showering, shower-boost pumps, appliances intended for medical purposes, and appliances intended for locations with special conditions such as corrosive or explosive atmospheres. It also notes that if an appliance includes a part within the scope of IEC 60598 or IEC 62368, that part is tested to the relevant standard as far as reasonable.
What are the key requirements of prEN IEC 60335-2-105:2026?
prEN IEC 60335-2-105:2026 focuses on electrical protection, moisture resistance, temperature limits, abnormal operation, and construction features that reduce the risk of shock, burns, pressure hazards, and fire. The main requirements are spread across Clauses 5 to 30 and Annex R.
Electrical protection and installation
- Clause 6 requires multifunctional shower cabinets and separate multifunctional shower units to be at least IPX4. In practice, the enclosure must resist splashing water, which is important because these appliances are used in wet areas.
- Clause 8 treats energized parts as live parts, with an exception for water level sensors under the stated conditions. This matters because accessible conductive parts and sensor arrangements must not create an electric shock risk.
- Clause 22 requires parts such as switches and controls accessible to the user in the shower cabinet to be supplied only at safety extra-low voltage not exceeding 12 V. That reduces the risk if a user touches a control while wet.
- Clause 27 requires Class I appliances to have a terminal for external equipotential bonding conductors. In practice, the installer must be able to bond the appliance into the building protective system.
Marking and instructions
- Clause 7 requires a warning near air outlets for appliances with an air-heating function unless the outlet is high enough or cannot be covered. This helps prevent overheating if a towel or other item blocks the outlet.
- Clause 7 also requires marking for the maximum power input of replaceable lamps and a hot-surface warning when water or steam outlet temperatures exceed the stated limit. Users need these warnings to avoid burns and overloading replacement lamps.
- The instructions must explain cleaning needed to maintain hygienic conditions and warn against using separate electrical appliances that produce steam or humidity inside the cabinet.
- The instructions must reference national wiring rules, state that earthed appliances must be permanently connected to fixed wiring, and advise supply through an RCD having a rated residual operating current not exceeding 30 mA. That guides the installer toward a safer connection in a wet environment.
Heating, moisture, and abnormal operation
- Clause 11 sets temperature-rise requirements for warm air and external accessible surfaces within the shower cabinet, and Table 101 gives the applicable limits. This is central to user safety because surfaces in contact with skin must not become too hot.
- Clause 11 also requires testing at 1.06 times rated voltage if the temperature-rise limits are exceeded and the measured power input is below rated power input. That checks whether the appliance still behaves safely when supply conditions vary.
- Clause 15 requires moisture-resistance testing, including treatment of the inside of the shower cabinet according to IEC 60529:1989, 14.2.5. Traces of water on insulation in components operating at safety extra-low voltage not exceeding 12 V are ignored.
- Clause 19 adds abnormal-operation tests for air-heating functions, and for steam bath functions the test is carried out without water being supplied. This checks that foreseeable faults do not create overheating or unsafe operation.
Steam, pressure, and construction
- Clause 22 requires appliances with a steam bath function to have safeguards against excessive pressure, and the pressure test checks for leakage and pressure increase under fault conditions. This is important because steam systems can become hazardous if pressure is not controlled.
- Clause 22 also requires steam outlets to be arranged so they do not direct steam toward the user, and appliances with water recirculation to leave no more than 0.15 l remaining in the system after use. These requirements reduce burn and hygiene concerns.
- Clause 29 sets the microenvironment pollution degree to 3 unless the insulation is enclosed or protected from condensation exposure. That affects insulation design and spacing choices.
- Clause 30 requires air heaters with substantially non-metallic enclosures to resist fire, checked by the needle-flame test of Annex E. That helps control ignition risk from hot internal parts.
Software-controlled functions
- Annex R applies to programmable electronic circuits that control functions affecting safety. It requires fault or error detection before compliance with Clause 19, 22.63, or 22.103 is impaired.
- Clause 22.103 requires the appliance to remain safe if programmable electronic circuits allow simultaneous activation of heaters and motors. In practice, the control logic must not rely on unsafe timing or interlocking assumptions.
What terms does prEN IEC 60335-2-105:2026 define?
- Multifunctional shower cabinet - A prefabricated shower cabinet that includes at least one additional function, such as a steam bath, besides showering.
- Separate multifunctional shower unit - A multifunctional shower unit without a prefabricated shower cabinet that includes at least one electric function in addition to showering.
- RCD - A residual current device used in the supply circuit to provide additional protection against electric shock.
- SELV - Safety extra-low voltage, used here for parts that are permitted only at very low voltage to reduce shock risk.
- Class I appliance - An appliance that uses protective earthing, and in this standard it also needs a terminal for external equipotential bonding conductors.
- Programmable electronic circuits - Control circuits using software that can influence whether safety-related functions operate correctly.
- Pollution degree 3 - The insulation environment assumed for the appliance unless it is sufficiently enclosed or protected from condensation.
- Warm air - Air discharged for warming parts of the human body, with temperature-rise limits given in Table 101.
Who uses prEN IEC 60335-2-105:2026?
prEN IEC 60335-2-105:2026 is used by manufacturers, test laboratories, certification bodies, installers, and compliance teams working with shower cabinets and similar spa or shower products. It is also relevant to designers and buyers who need to check whether a product has the safety features expected for wet-area electrical equipment.
In practice, engineers use it to design enclosures, controls, heating systems, and software logic. Quality managers and buyers use it to verify markings, instructions, protective measures, and test evidence before placing the product on the market or accepting it from a supplier.
What changed in prEN IEC 60335-2-105:2026 from the previous edition?
prEN IEC 60335-2-105:2026 supersedes EN IEC 60335-2-105:2021, including Amendment 1:2021 and Amendment 11:2021, and it also replaces the second edition published in 2016 and Amendment 1:2019. The stated technical changes are:
- alignment with IEC 60335-1:2020;
- conversion of some notes to normative text in Clause 1;
- updated surface temperature requirements in 11.8 and Table 101.
Which standards are used with prEN IEC 60335-2-105:2026?
- IEC 60335-1 - The base general safety standard that this part 2 uses and modifies.
- IEC 60529:1989, 14.2.5 - Used for the moisture-resistance test applied to the inside of the shower cabinet.
- IEC 60695-11-10 - Used for the V-0 and V-1 flammability classification referenced for some non-metallic materials.
- IEC 60335-2-35 - Identified as the separate standard for instantaneous water heaters used for showering, which are outside this part’s scope.
- IEC 60335-2-41 - Identified as the separate standard for shower-boost pumps, which are outside this part’s scope.
- IEC 62368 (all parts) - Named for parts of appliances that fall within its scope and are tested to that standard as far as reasonable.
- prEN IEC 60335-2-105:2026/prAA:2026 - The European foreword says this draft is read in conjunction with this companion draft.
What does the prEN IEC 60335-2-105:2026 document contain?
The document contains the full Part 2 structure with clauses for scope, references, terms, testing conditions, classification, marking, protection against access to live parts, heating, moisture resistance, abnormal operation, construction, and fire-related hazards. It also contains the special annex for software evaluation, which is relevant when safety depends on programmable electronic circuits.
It provides the details behind the key test work, including the temperature-rise table for surfaces and air outlets, pressure checks for steam systems, and the fault-or-error conditions used for software-related evaluation. The informative annexes give example layouts of a multifunctional shower cabinet and a separate multifunctional shower unit, which helps users understand the intended product forms without reproducing the requirements themselves.
The annexes and clauses are designed for design verification, type testing, and safety assessment of wet-area electrical equipment. Figures and tables support the test interpretation, while the normative annex and clause-specific tests show where safety depends on hardware, software, installation, and enclosure design together.
Relations
- Effective Date
- 28-Apr-2026
- Effective Date
- 28-Apr-2026
- Effective Date
- 28-Apr-2026
- Effective Date
- 28-Apr-2026
Get Certified
Connect with accredited certification bodies for this standard
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Kmetijski inštitut Slovenije
Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.
Sponsored listings
Frequently Asked Questions
prEN IEC 60335-2-105:2026 is a draft published by CLC. Its full title is "Household and similar electrical appliances - Safety - Part 2-105: Particular requirements for multifunctional shower cabinets". This standard covers: This documents deals with the safety of electric multifunctional shower cabinets and electric separate multifunctional shower units for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances including DC supplied appliances. Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in hotels, fitness centres and similar locations, are within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home.
This documents deals with the safety of electric multifunctional shower cabinets and electric separate multifunctional shower units for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances including DC supplied appliances. Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in hotels, fitness centres and similar locations, are within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home.
prEN IEC 60335-2-105:2026 is classified under the following ICS (International Classification for Standards) categories: 13.120 - Domestic safety; 97.170 - Body care equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
prEN IEC 60335-2-105:2026 has the following relationships with other standards: It is inter standard links to prEN IEC 60335-2-105:2026/prAA:2026, EN IEC 60335-2-105:2021/A11:2021, EN IEC 60335-2-105:2021/A1:2021, EN IEC 60335-2-105:2021. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
prEN IEC 60335-2-105:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/35/EU, 2014/53/EU; Standardization Mandates: M/511, M/536. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
prEN IEC 60335-2-105:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.5 Definitions relating to types of appliances
- 4 General requirement
- 5 General conditions for the tests
- 6 Classification
- 7 Marking and instructions
- 8 Protection against access to live parts
- 9 Starting of motor-operated appliances
- 10 Power input and current
- 11 Heating
- 12 Charging of metal-ion batteries
- 13 Leakage current and electric strength at operating temperature
- 14 Transient overvoltages
- 15 Moisture resistance
- 16 Leakage current and electric strength
- 17 Overload protection of transformers and associated circuits
- 18 Endurance
- 19 Abnormal operation
- 20 Stability and mechanical hazards
- 21 Mechanical strength
- 22 Construction
- 23 Internal wiring
- 24 Components
- 25 Supply connection and external flexible cords
- 26 Terminals for external conductors
- 27 Provision for earthing
- 28 Screws and connections
- 29 Clearances, creepage distances and solid insulation
- 30 Resistance to heat and fire
- 31 Resistance to rusting
- 32 Radiation, toxicity and similar hazards
- Annex R
- Annex AA
- Annex BB
- Bibliography
INTRODUCTION It has been assumed in the drafting of this International Standard that the execution of its provisions is entrusted to appropriately qualified and experienced persons. Guidance documents concerning the application of the safety requirements for appliances can be accessed via TC 61 supporting documents on the IEC website https://www.iec.ch/tc61/supportingdocuments This information is given for the convenience of users of this International Standard and does not constitute a replacement for the normative text in this standard. This standard recognizes the internationally accepted level of protection against hazards such as electrical, mechanical, thermal, fire and radiation of appliances when operated as in normal use taking into account the manufacturer's instructions. It also covers abnormal situations that can be expected in practice and takes into account the way in which electromagnetic phenomena can affect the safe operation of appliances.
This standard takes into account the requirements of IEC 60364 as far as possible so that there is compatibility with the wiring rules when the appliance is connected to the supply mains. However, national wiring rules can differ.
If an appliance within the scope of this standard also incorporates functions that are covered by another part 2 of IEC 60335, the relevant part 2 is applied to each function separately, as far as is reasonable. If applicable, the influence of one function on the other is taken into account.
When a part 2 standard does not include additional requirements to cover hazards dealt with in Part 1, Part 1 applies.
NOTE 1 This means that the technical committees responsible for the part 2 standards have determined that it is not necessary to specify particular requirements for the appliance in question over and above the general requirements.
This standard is a product family standard dealing with the safety of appliances and takes precedence over horizontal and generic standards covering the same subject. NOTE 2 Horizontal publications, basic safety publications and group safety publications covering a hazard are not applicable since they have been taken into consideration when developing the general and particular requirements for the IEC 60335 series of standards.
An appliance that complies with the text of this standard will not necessarily be considered to comply with the safety principles of the standard if, when examined and tested, it is found to have other features that impair the level of safety covered by these requirements. An appliance employing materials or having forms of construction differing from those detailed in the requirements of this standard may be examined and tested according to the intent of the requirements and, if found to be substantially equivalent, may be considered to comply with the standard.
NOTE 3 Standards dealing with non-safety aspects of household appliances are:
- IEC standards published by TC 59 concerning methods of measuring performance;
- CISPR 11, CISPR 14-1 and relevant IEC 61000-3 series standards concerning electromagnetic emissions;
- CISPR 14-2 concerning electromagnetic immunity;
- IEC standards published by TC 111 concerning environmental matters.
oSIST prEN IEC 60335-2-105:2026
1 Scope
This clause of Part 1 is replaced by the following.
This part of IEC 60335 deals with the safety of electric multifunctional shower cabinets and electric separate multifunctional shower units for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances including DC supplied appliances.
Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laymen in hotels, fitness centres and similar locations, are within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account - persons (including children) whose - physical, sensory or mental capabilities; or - lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction; - children playing with the appliance.
Attention is drawn to the fact that - for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary; - in many countries, additional requirements are specified by the national health authorities, the national water supply authorities, the national authorities responsible for the protection of labour and similar authorities; - in many countries, mechanical strength, impact resistance and shattering properties of shower enclosures can be covered by national regulations.
If an appliance incorporates a part that is within the scope of IEC 60598 series or IEC 62368 series, the part is tested in accordance with the relevant standard as far as reasonable. This standard does not apply to - instantaneous water heaters used for showering (IEC 60335-2-35); - shower-boost pumps (IEC 60335-2-41); - appliances intended for medical purposes; - appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas).
2 Normative references
This clause of Part 1 is applicable.
oSIST prEN IEC 60335-2-105:2026
3 Terms and definitions
This clause of Part 1 is applicable except as follows.
3.5 Definitions relating to types of appliances
3.5.101 multifunctional shower cabinet prefabricated shower cabinet that incorporates at least one other function, such as a steam bath, in addition to the showering function Note 1 to entry: An example of a multifunctional shower cabinet is shown in informative Annex AA. 3.5.102 separate multifunctional shower unit multifunctional shower unit without a prefabricated shower cabinet that incorporates at least one electric function in addition to the showering function Note 1 to entry: An example of a separate multifunctional shower unit is shown in informative Annex BB.
4 General requirement
This clause of Part 1 is applicable.
5 General conditions for the tests
This clause of Part 1 is applicable except as follows.
5.4 Addition:
When testing a function of the appliance, the influence of another function that can be applied simultaneously is taken into account.
5.6 Addition:
Sensing elements located in the air intake to the heater are short-circuited or otherwise rendered inoperative.
6 Classification
This clause of Part 1 is applicable except as follows.
6.2 Addition:
Multifunctional shower cabinets and separate multifunctional shower units shall be at least IPX4.
oSIST prEN IEC 60335-2-105:2026
7 Marking and instructions
This clause of Part 1 is applicable except as follows.
7.1 Addition:
Appliances with an air-heating function, other than those having the air outlet located at a height at least 1,8 m above the floor or those that cannot be covered, shall be marked near the air outlet with symbol IEC 60417-6096 (2012-01) or with the substance of the following:
WARNING: Do not cover Appliances shall be marked on or near the lampholder with the maximum power input of replaceable lamps as follows:
...