Abstract

1.1   Scope of EN 19100-1
(1) This document gives basic design rules for glass structures, assemblies and components. This document is concerned with the requirements for resistance, serviceability, fracture characteristics and glass component failure consequences in relation to human safety, robustness and redundancy of glass structures.
(2) This document covers the basis of design, structural design, materials, durability, and construction rules.
1.2   Assumptions
(1) The assumptions given in EN 1990-1 apply.
(2) This document is intended to be used in conjunction with EN 1990-1, EN 1991 (all parts), the parts of EN 1992 to EN 1999 where glass structures or glass components are referred to within those documents and EN 12488.

Status
Not Published
Public Enquiry End Date
28-Nov-2024
Technical Committee
KON - Structures
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
27-Mar-2026
Due Date
15-May-2026

Buy Documents

Draft

oSIST prEN 19100-1:2024

English language (43 pages)
Preview
Preview
e-Library read for
×1 day

kSIST FprEN 19100-1:2026 is a CEN Eurocode for the design of glass structures. It gives the general rules for mechanically supported glass structures, assemblies and components, with requirements for resistance, serviceability, fracture behaviour, durability, human safety, robustness and redundancy. It is intended to be used with EN 1990, EN 1991, the relevant parts of EN 1992 to EN 1999 where glass is referenced, and EN 12488.

What does kSIST FprEN 19100-1:2026 specify?

kSIST FprEN 19100-1:2026 specifies the basic design rules for glass structures, assemblies and components. It covers the basis of design, structural design, materials, durability and construction rules, so it is the general reference document before moving to the more specific loading parts.

The scope is focused on structural performance and failure consequences. That matters in practice because glass design is not only about keeping the glass intact - it also has to address what happens if fracture occurs, how the structure remains safe, and how redundancy is achieved.

The document is organized into clauses on scope, references, terms, basis of design, materials, durability, structural analysis, ultimate limit state and serviceability limit state, followed by three informative annexes.

AnnexWhat it covers
Annex ADesign bending strength
Annex BIn-plane thermally induced stress
Annex CRisk Assessment

Clause 0 explains the Eurocode framework, the meaning of the verbal forms, and how National Annex choices work. Clause 1 states the scope, Clause 2 lists the normative references, and Clause 3 defines the main terms and symbols used throughout the document.

What are the key requirements of kSIST FprEN 19100-1:2026?

kSIST FprEN 19100-1:2026 sets the design basis for glass structures around EN 1990 limit state design, consequence classes, design working life and specific fracture-related checks. In practice, this means the designer has to decide early how the glass is intended to behave, what failure consequences are acceptable, and whether the structure needs a maintenance concept or special replaceability provisions.

Basis of design and limit states

Clause 4 requires glass structures to follow the general rules of EN 1990 and adds glass-specific provisions for resistance, serviceability, durability and robustness. It also requires classification by consequence class and encourages design for a design working life consistent with the rest of the primary structure.

The document uses four limit states for glass:

  • SLS for unfractured service conditions
  • ULS for safety of unfractured glass
  • FLS during fracture
  • PFLS after fracture

That matters because glass may be safe in the intact state but still need separate checks for safe fracture and residual load capacity after breakage.

Actions and load combinations

Clause 4 requires action effects to be taken from EN 1991, including regional, climatic and accidental actions. For insulating glass units (IGUs), the document also requires cavity pressure variations to be considered, including temperature change, altitude difference and atmospheric pressure change.

The document also points to settlements, support stiffness, construction stages and seismic actions. For vertical glazing, it gives rules for distributing horizontal point and line loads over defined areas, and for horizontal glazing it gives a similar rule for vertical point loads. In practice, this means the load model has to match the real support and exposure condition, not just a simplified global load.

Materials and product standards

Clause 5 ties design properties to the relevant product standards. For basic soda lime silicate glass, the document gives design-relevant physical and mechanical properties, and it distinguishes between annealed glass and thermally pre-stressed glass.

It also covers other glass types, interlayers, IGUs and materials for further load transfer elements such as glazing blocks and mechanical fittings. The practical message is that the structural model must use the correct product standard, the correct glass type and the correct material data for the actual assembly.

Structural analysis and detailing

Clause 7 requires an appropriate structural calculation model that reflects boundary conditions and load modelling. For glass, the document assumes linear elasticity and no ductility, while other connected materials such as interlayers, glues and plastics may need nonlinear treatment where relevant.

For laminated glass, the document requires a suitable interlayer model and describes three modelling levels. It also gives support rules, rules for possible restraints, and special provisions for drill holes and recesses. In practice, this is where the designer checks how the glass is held, whether local stress peaks occur, and whether holes or cut-outs require pre-stressed glass and careful edge treatment.

Ultimate and serviceability limit states

Clause 8 sets the ULS verification, including the comparison of design effect and design resistance. It also introduces partial factors for basic material strength and surface pre-stress, with values linked to consequence class and design situation.

Clause 9 covers SLS and introduces deformation classes for different levels of criticality. This helps the designer decide whether a deflection is only cosmetic, affects functionality, or becomes a safety issue.

What terms does kSIST FprEN 19100-1:2026 define?

  • Glass component - a monolithic, laminated or insulating glass unit after installation.
  • Glass member - a glass component with clear mechanical boundary conditions so its stress or sectional forces can be calculated.
  • Insulating glass unit (IGU) - an assembly of at least two panes separated by spacers and hermetically sealed along the periphery.
  • Limit state scenario (LSS) - the set of limit states selected for a glass component, covering SLS, ULS, FLS and PFLS as needed.
  • Fracture limit state (FLS) - the state where safe behaviour during accidental fracture is no longer satisfied.
  • Post fracture limit state (PFLS) - the state where the required residual load-bearing capacity after fracture is no longer satisfied.
  • Consequence class (CC) - the class used to reflect the consequences of failure or malfunction.
  • Interlayer - one or more adhesive layers between plies of glass or plastic glazing sheet material.

Who uses kSIST FprEN 19100-1:2026?

kSIST FprEN 19100-1:2026 is used by designers of mechanically supported glass components and assemblies, especially where structural safety and fracture behaviour have to be defined clearly. It is also relevant to anyone who has to select glass types, define boundary conditions, or document load cases and material assumptions.

Typical users include:

  • structural engineers and glass designers
  • clients and buyers who need a technical basis for project requirements
  • manufacturers and fabricators of glass components
  • constructors and installers who need the assembly rules and support assumptions
  • relevant authorities setting national choices or project-specific requirements
  • software developers implementing glass design calculations
  • committees writing related product, testing and execution standards

What changed in kSIST FprEN 19100-1:2026 from the previous edition?

kSIST FprEN 19100-1:2026 supersedes CEN/TS 19100-1:2021. The changes stated in the foreword are:

  • modified title and scope
  • updated references
  • improved provisions for action
  • improved provisions for coefficients and factor values
  • combined former Annex A and Annex B into a new Annex A on design bending strength

Which standards are used with kSIST FprEN 19100-1:2026?

StandardWhat it contributes
EN 1990:2023Basis of structural and geotechnical design, limit states, partial factor method and consequence classes
EN 1991 (all parts)Actions on structures, including climatic, regional and accidental actions
EN 12488Glazing recommendations and assembly principles for vertical and sloping glazing
EN 572 (all parts)Basic soda lime silicate glass products
EN 1279-5:2018IGU product requirements
EN 13022-1Glass products for structural sealant glazing systems
EN 13022-2Assembly rules for structural sealant glazing
EN 15434-1Bonded glazing sealants for direct light exposure
EN 16613Determination of interlayer viscoelastic properties
prEN 17940:2023Folio interlayers for laminated glass manufacture
EN 19100-2Out-of-plane loaded glass components
EN 19100-3In-plane loaded glass components

The document also relies on the parts of EN 1992 to EN 1999 where glass structures or glass components are referenced within those standards.

What does the kSIST FprEN 19100-1:2026 document contain?

kSIST FprEN 19100-1:2026 contains the core design framework for glass structures, including the terminology, symbols and design rules needed before detailed member checks are made. It gives tables for key material properties, product standards, deformation classes, partial factors and interlayer modelling levels.

The document also contains methods for combining actions, verifying resistance, and handling special effects such as cavity pressure variations and thermal stresses. Annex A provides the calculation guidance for design bending strength, Annex B gives guidance for determining thermal gradients and in-plane thermal stress, and Annex C gives a risk-assessment approach for classifying glass components and selecting a suitable glass assembly.

For practice, the document is mainly used for structural design, verification and project specification. It tells the reader what must be checked, what supporting standards to use, and where calculation methods are provided for the most important glass-specific cases.

Relations

Effective Date
09-Sep-2026
Effective Date
09-Sep-2026
Effective Date
09-Sep-2026
Effective Date
09-Sep-2026
Effective Date
09-Sep-2026
Effective Date
09-Sep-2026
Effective Date
09-Sep-2026
Effective Date
09-Sep-2026
Effective Date
09-Sep-2026
Effective Date
09-Sep-2026
Effective Date
09-Sep-2026
Effective Date
09-Sep-2026
Effective Date
09-Sep-2026
Effective Date
09-Sep-2026
Effective Date
09-Sep-2026

Buy Documents

Draft

oSIST prEN 19100-1:2024

English language (43 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

kSIST FprEN 19100-1:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Eurocode 10 - Design of glass structures - Part 1: General rules". This standard covers: 1.1 Scope of EN 19100-1 (1) This document gives basic design rules for glass structures, assemblies and components. This document is concerned with the requirements for resistance, serviceability, fracture characteristics and glass component failure consequences in relation to human safety, robustness and redundancy of glass structures. (2) This document covers the basis of design, structural design, materials, durability, and construction rules. 1.2 Assumptions (1) The assumptions given in EN 1990-1 apply. (2) This document is intended to be used in conjunction with EN 1990-1, EN 1991 (all parts), the parts of EN 1992 to EN 1999 where glass structures or glass components are referred to within those documents and EN 12488.

1.1 Scope of EN 19100-1 (1) This document gives basic design rules for glass structures, assemblies and components. This document is concerned with the requirements for resistance, serviceability, fracture characteristics and glass component failure consequences in relation to human safety, robustness and redundancy of glass structures. (2) This document covers the basis of design, structural design, materials, durability, and construction rules. 1.2 Assumptions (1) The assumptions given in EN 1990-1 apply. (2) This document is intended to be used in conjunction with EN 1990-1, EN 1991 (all parts), the parts of EN 1992 to EN 1999 where glass structures or glass components are referred to within those documents and EN 12488.

kSIST FprEN 19100-1:2026 is classified under the following ICS (International Classification for Standards) categories: 81.040.20 - Glass in building; 91.080.99 - Other structures. The ICS classification helps identify the subject area and facilitates finding related standards.

kSIST FprEN 19100-1:2026 has the following relationships with other standards: It is inter standard links to kSIST FprEN 1991-1-1:2024, SIST EN 15434-1:2023, SIST EN 572-7:2012, kSIST FprEN 1991-1-4:2025, SIST EN 572-6:2012, kSIST FprEN 1991-3:2025, SIST EN 572-2:2012, SIST EN 13022-1:2014, SIST EN 572-8:2012+A1:2016, kSIST FprEN 1991-1-8:2025, kSIST FprEN 1991-1-9:2024, SIST EN 572-4:2012, SIST EN 13022-2:2014, kSIST FprEN 1991-4:2025, kSIST FprEN 1991-1-5:2024. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

kSIST FprEN 19100-1:2026 is associated with the following European legislation: Standardization Mandates: M/515. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

kSIST FprEN 19100-1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 0 Introduction
  • 0.1 Introduction to the Eurocodes
  • 0.2 Introduction to EN 19100 (all parts)
  • 0.4 Verbal forms used in the Eurocodes
  • Annex A Annex B Annex C
  • 1 Scope
  • 1.2 Assumptions
  • 2 Normative references
  • 3 Terms, definitions and symbols
  • 3.1 Terms and definitions
  • 3.1.1 glass component
  • 3.1.2 glass member
  • 3.1.3 insulating glass unit
  • 3.1.4 limit state scenario
  • 3.1.5 ultimate limit state
  • 3.1.6 serviceability limit state
  • 3.1.7 failure
  • 3.1.8 fracture
  • 3.1.9 fracture limit state
  • 3.1.10 post fracture limit state
  • 3.1.11 redundancy
  • 3.1.12 robustness
  • 3.1.13 ply
  • 3.1.14 in-plane loaded glass component
  • 3.1.15 out-of-plane loaded glass component
  • 3.1.16 vertical glass component
  • 3.1.17 interlayer
  • 3.1.18 laminated glass
  • 3.1.19 laminated safety glass
  • 3.1.20 effective thickness
  • 3.1.21 thermal stress
  • 3.1.22 cavity pressure
  • 3.1.23 variable cavity loading
  • 3.1.24 permanent cavity loading
  • 3.1.25 pre-stressed glass
  • 3.1.26 mid plane of a hole
  • 3.1.27 glazing block
  • 3.1.28 annealed glass
  • 3.1.29 float glass
  • 3.1.30 patterned glass
  • 3.1.31 wired patterned glass
  • 3.1.32 polished wired glass
  • 3.1.33 drawn sheet glass
  • 3.1.34 surface pre-stress
  • 3.1.35 European Technical Product Specification
  • 3.2 Symbols and abbreviations
  • 4 Basis of design
  • 4.1 Requirements
  • 4.2 Principles of limit state design
  • 4.3 Basic variables
  • 4.4 Verification by the partial factor method
  • 5 Materials
  • 5.1 Glass
  • 75 N/mm 45 N/mm
  • 5.2 Interlayer
  • 5.3 Insulating glass units (IGUs)
  • 5.4 Material for further load transfer elements
  • 6 Durability
  • 7 Structural analysis
  • 7.1 Basic assumptions
  • 7.2 Determination of sectional forces, stresses and deformations
  • 7.3 General structural provisions
  • 8 Ultimate limit state
  • 8.1 General
  • 8.2 Partial factors
  • 8.3 Resistance
  • 9 Serviceability limit states
  • 9.1 General
  • 9.2 Deformation classes
  • Annex A
  • Annex B
  • Annex C
  • Bibliography

0 Introduction

0.1 Introduction to the Eurocodes

The Structural Eurocodes comprise the following standards generally consisting of a number of Parts:

  • EN 1990 Eurocode — Basis of structural and geotechnical design
  • EN 1991 Eurocode 1 — Actions on structures
  • EN 1992 Eurocode 2 — Design of concrete structures
  • EN 1993 Eurocode 3 — Design of steel structures
  • EN 1994 Eurocode 4 — Design of composite steel and concrete structures
  • EN 1995 Eurocode 5 — Design of timber structures
  • EN 1996 Eurocode 6 — Design of masonry structures
  • EN 1997 Eurocode 7 — Geotechnical design
  • EN 1998 Eurocode 8 — Design of structures for earthquake resistance
  • EN 1999 Eurocode 9 — Design of aluminium structures
  • EN 19100 Eurocode 10 — Design of glass structures The Eurocodes are intended for use by designers, clients, manufacturers, constructors, relevant authorities (in exercising their duties in accordance with national or international regulations), educators, software developers, and committees drafting standards for related product, testing and execution standards.

NOTE Some aspects of design are most appropriately specified by relevant authorities or, where not specified, can be agreed on a project-specific basis between relevant parties such as designers and clients. The Eurocodes identify such aspects making explicit reference to relevant authorities and relevant parties.

0.2 Introduction to EN 19100 (all parts)

EN 19100 (all parts) applies to the structural design of mechanically supported glass components and assemblies of glass components. It complies with the principles and requirements for the safety and serviceability of structures, the basis of their design and verification that are given in EN 1990, Basis of structural and geotechnical design.

EN 19100 is subdivided into three parts:

  • EN 19100-1, Eurocode 10 — Design of glass structures — Part 1: General rules
  • EN 19100-2, Eurocode 10 — Design of glass structures — Part 2: Out-of-plane loaded glass components
  • EN 19100-3, Eurocode 10 — Design of glass structures — Part 3: In-plane loaded glass components 0.3 Introduction to EN 19100-1 EN 19100-1 applies to the structural design of mechanically supported glass components and assemblies of glass components according to EN 19100-2 and EN 19100-3.

oSIST prEN 19100-1:2024 prEN 19100-1:2024 (E)

0.4 Verbal forms used in the Eurocodes

The verb “shall" expresses a requirement strictly to be followed and from which no deviation is permitted in order to comply with the Eurocodes.

The verb “should” expresses a highly recommended choice or course of action. Subject to national regulation and/or any relevant contractual provisions, alternative approaches could be used/adopted where technically justified.

The verb “may" expresses a course of action permissible within the limits of the Eurocodes. The verb “can" expresses possibility and capability; it is used for statements of fact and clarification of concepts.

0.5 National Annex for EN 19100-1 National choice is allowed in this document where explicitly stated within notes. National choice includes the selection of values for Nationally Determined Parameters (NDPs). The national standard implementing EN 19100-1 can have a National Annex containing all national choices to be used for the design of buildings and civil engineering works to be constructed in the relevant country.

When no national choice is given, the default choice given in this document is to be used. When no national choice is made and no default is given in this document, the choice can be specified by a relevant authority or, where not specified, agreed for a specific project by appropriate parties. National choice is allowed in EN 19100-1 through notes to the following clauses:

3.1.16 4.2.4(1) 4.3.1 (3) – 2 choices 4.3.1(8) 4.3.1(9) 4.3.1(10) 4.4.2(2) 4.4.2(3) 5.2(1) 7.2.2(2) 7.2.2(3) 7.2.2(4) 8.2(2) 8.3.2(1) 9.2(1) National choice is allowed in EN 19100-1 on the application of the following informative annexes:

Annex A Annex B Annex C

The National Annex can contain, directly or by reference, non-contradictory complementary information for ease of implementation, provided it does not alter any provisions of the Eurocodes.

oSIST prEN 19100-1:2024 prEN 19100-1:2024 (E)

1 Scope

1.1 Scope of prEN 19100-1 (1) This document gives basic design rules for glass structures, assemblies and components. This document is concerned with the requirements for resistance, serviceability, fracture characteristics and glass component failure consequences in relation to human safety, robustness and redundancy of glass structures.

(2) This document covers the basis of design, structural design, materials, durability, and construction rules.

1.2 Assumptions

(1) The assumptions given in EN 1990 apply.

(2) This document is intended to be used in conjunction with EN 1990, EN 1991 (all parts), the parts of EN 1992 to EN 1999 where glass structures or glass components are referred to within those documents and EN 12488.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE See the Bibliography for a list of other documents cited that are not normative references, including those referenced as recommendations (i.e. through ‘should’ clauses) and permissions (i.e. through ‘may’ clauses). EN 572 (all parts), Glass in building — Basic soda lime silicate glass products EN 1279-5:2018, Glass in building — Insulating glass units — Part 5: Product standard

EN 1990:2023, Eurocode — Basis of structural and geotechnical design EN 1991 (all parts), Eurocode 1 — Actions on structures EN 12488, Glass in building — Glazing recommendations — Assembly principles for vertical and sloping glazing EN 13022-1, Glass in building — Structural sealant glazing — Part 1: Glass products for structural sealant glazing systems for supported and unsupported monolithic and multiple glazing EN 13022-2, Glass in building — Structural sealant glazing — Part 2: Assembly rules EN 15434-1, Bonding sealants — Part 1: Bonded glazing sealants for direct light exposure

3 Terms, definitions and symbols

3.1 Terms and definitions

For the purposes of this document, the terms and definitions given in EN 1990 and the following apply.

As impacted by EN 1990:2023/prA1:2024.

oSIST prEN 19100-1:2024 prEN 19100-1:2024 (E)

Table 3.1— Glass component, glass member and system of glass members Monolithic glass

Key 1 pane 2 single ply

Laminated glass Key 1 pane Glass 2 ply component 3 interlayer Insulated glass unit (IGU)

Key 1 pane 2 ply 3 interlayer 4 cavity 5 spacer Glass Glass component + member boundary conditions System of Glass components + their glass interconnections + members boundary conditions

3.1.1 glass component

glass product being monolithic, laminated, and/or insulating glass unit, after installation Note 1 to entry: See Table 3.1.

oSIST prEN 19100-1:2024 prEN 19100-1:2024 (E)

3.1.2 glass member

glass component with clear mechanical boundary conditions so that the effects (stresses or sectional forces) of a defined action can be calculated Note 1 to entry: See Table 3.1.

3.1.3 insulating glass unit

IGU assembly consisting of at least two panes of glass, separated by one or more spacers, hermetically sealed along the periphery, mechanically stable and durable

3.1.4 limit state scenario

LSS set of limit states (SLS, ULS, FLS and PFLS) to be verified whilst designing a glass component

3.1.5 ultimate limit state

ULS state associated with collapse or other forms of structural failure Note 1 to entry: Generally, it corresponds to the maximum load-carrying resistance of a structure or structural member.

[SOURCE: EN 1990:2023, 3.1.2.15]

3.1.6 serviceability limit state

SLS state that correspond to conditions beyond which specified service requirements for a structure or structural member are no longer met [SOURCE: EN 1990:2023, 3.1.2.16]

3.1.7 failure

event where the total loss of structural resistance of the glass component or supports or bonding occurs

3.1.8 fracture

macroscopic physical disintegration due to crack propagation in glass Note 1 to entry: For a monolithic glass pane, a glass fracture results into a failure of the component. For a laminated glass pane, fracture of a ply or even of all plies does not necessarily result into a failure of the component. For an IGU, fracture of one glass pane does not necessarily result into failure of the component.

oSIST prEN 19100-1:2024 prEN 19100-1:2024 (E)

3.1.9 fracture limit state

FLS ultimate limit state beyond which, during accidental fracture of a glass component or part of glass component, the following requirements are no longer satisfied - the prevention of injuries by contact with glass fragments and/or, - the prevention of body to pass through and/or, - the ability to limit the failure to that glass component or part of glass component Note 1 to entry: The requirements can usually be satisfied by choosing an appropriate mode of breakage of glass, boundary conditions and other mechanical characteristics.

3.1.10 post fracture limit state

PFLS ultimate limit state beyond which, in case of accidental failure of a glass component, the required residual load bearing capacity provided by - redundancy of the glass component, - undamaged ply(ies) of that glass component, - structure alternative load path(s) during a defined period is no longer satisfied

3.1.11 redundancy

provision or existence of additional load paths or structural systems than strictly necessary to resist design actions

3.1.12 robustness

ability of a structure to withstand unforeseen adverse events without being damaged to an extent disproportionate to the original cause [SOURCE: EN 1990:2023, 3.1.2.30] Note 1 to entry: See EN 1990 and EN 1991-1-7.

3.1.13 ply

sheet of monolithic glass, cut to size and shape

3.1.14 in-plane loaded glass component

glass component subjected to a significant force component parallel to the glass surface

3.1.15 out-of-plane loaded glass component

glass component subjected to a significant force component perpendicular to the glass surface

oSIST prEN 19100-1:2024 prEN 19100-1:2024 (E)

3.1.16 vertical glass component

glass component which subtends an angle of no more than ± 15° to the vertical Note 1 to entry: The value of the angle is given in EN 13830, unless the National Annex gives a different value.

3.1.17 interlayer

one or more layers of material acting as an adhesive between plies of glass and/or plastic glazing sheet material Note 1 to entry: The interlayer can also give additional performance to the finished product, for example impact resistance, resistance to fire, solar control and acoustic insulation. Note 2 to entry: The interlayer itself can also encapsulate non-adhesive films and plates, wires, grids, photovoltaic cells, etc.

[SOURCE: EN ISO 12543-1:2021, 3.2.7, modified]

3.1.18 laminated glass

assembly consisting of one ply of glass with one or more plies of glass and/or plastic glazing sheet material joined together with one or more interlayers Note 1 to entry: The number of glass plies and the requirements on the interlayer depend on the application of the glass component, required performance and processing capability, etc. [SOURCE: EN ISO 12543-1:2021, 3.1.1, modified]

3.1.19 laminated safety glass

laminated glass classified in accordance with a soft body impact standard where in the case of breakage the interlayer serves to retain the glass fragments, limits the size of opening, offers residual resistance and reduces the risk of cutting or piercing injuries [SOURCE: EN ISO 12543-1:2021, 3.1.2]

3.1.20 effective thickness

mechanically equivalent thickness used in structural calculation to represent the “as if monolithic thickness” of laminated glass when calculating its resistance or stiffness

3.1.21 thermal stress

stress induced by thermal expansion, e.g. due to temperature differences in the glass

3.1.22 cavity pressure

pressure applied to the panes of insulating glass units due to the internal volume of the hermetically sealed cavity or cavities being affected by variable cavity loading and permanent cavity loading

3.1.23 variable cavity loading

pressure acting on the panes of insulating glass unit resulting from the effect of sealed cavity volume variations due to temperature and atmospheric changes

oSIST prEN 19100-1:2024 prEN 19100-1:2024 (E)

3.1.24 permanent cavity loading

pressure acting on the panes of insulating glass unit resulting solely from a difference in altitude between the place of assembly (sealing) and the place of use

3.1.25 pre-stressed glass

glass within which a permanent surface compressive stress has been induced by a controlled process in order to give it increased resistance to mechanical and thermal stress and/or prescribed fracture characteristics Note 1 to entry: Pre-stressed glasses can be thermally toughened glass, heat soaked thermally toughened glass, heat strengthened glass or chemically strengthened glass.

3.1.26 mid plane of a hole

symmetry plane of a hole in a glass ply, which is parallel to the glass surfaces

3.1.27 glazing block

piece of suitable material, placed between the glass component and the frame preventing direct contact between the two of them Note 1 to entry: Glazing blocks include setting blocks, location blocks and distance pieces, see EN 12488.

3.1.28 annealed glass

glass as delivered directly from the fabrication cycle without subsequent treatment [SOURCE: ISO 12216:2020, 3.7.1]

3.1.29 float glass

flat, transparent, clear or tinted soda-lime silicate glass having parallel and polished faces obtained by continuous casting and flotation on a metal bath [SOURCE: ISO 16293-1:2008, 3.1]

3.1.30 patterned glass

flat, translucent, clear or tinted soda-lime silicate glass obtained by continuous casting and rolling [SOURCE: EN 572-1:2012+A1:2016, 3.3]

3.1.31 wired patterned glass

flat, translucent, clear or tinted soda-lime silicate glass obtained by continuous casting and rolling which has a steel mesh welded at all intersections incorporated in the glass during its manufacturing process Note 1 to entry: The surfaces can be either patterned or plain. Note 2 to entry: In German, wired patterned glass with plain surfaces is called ‘Drahtglas’.

oSIST prEN 19100-1:2024 prEN 19100-1:2024 (E)

3.1.32 polished wired glass

flat, transparent, clear soda-lime silicate glass having parallel and polished faces obtained by grinding and polishing the faces of wired patterned glass Note 1 to entry: The surfaces can be either patterned or plain. Note 2 to entry: In German, wired patterned glass with plain surfaces is called ‘Drahtglas’.

3.1.33 drawn sheet glass

flat, transparent, clear or tinted soda-lime silicate glass obtained by continuous drawing, initially vertically, of a regular thickness and with the two surfaces fire polished [SOURCE: EN 572-1:2012+A1:2016, 3.2]

3.1.34 surface pre-stress

permanent surface compression induced by pre-stressing technologies

3.1.35 European Technical Product Specification

European Standard (EN), European Technical Specification (TS) or a transparent and reproducible assessment that complies with all the requirements of an EAD

3.2 Symbols and abbreviations

For the purposes of this document, the following symbols and abbreviations apply.

3.2.1 Latin upper-case letters

E Modulus of elasticity E Design value of effect of actions d F Design value of an action d G Interlayer shear modulus or interlayer shear relaxation modulus int N Design value of normal forces in the relevant direction of the considered cross section or joint Ed N Design value of resisting normal forces in the direction of the corresponding effect Rd M Design value of moments in the relevant direction of the considered cross section or joint Ed M Design value of resisting moments in the direction of the corresponding effect Rd R Design values for resistance d R Characteristic value for resistance k T External air temperature ext T Maximum summer air temperature on the building site max T Minimum winter air temperature on the building site min

oSIST prEN 19100-1:2024 prEN 19100-1:2024 (E)

V Design value of transverse forces in the relevant direction of the considered cross section or Ed joint V Design value of resisting transverse forces in the direction of the corresponding effect Rd X Characteristic value of a material property k

3.2.2 Latin lower-case letters

f Characteristic value of glass strength after a strengthening treatment b,k f Design value of bending strength of glass g,d f Characteristic value of bending strength of annealed glass g,k h Glass ply thickness k Edge or hole finishing factor e k Edge or hole prestress factor e,p k Interference factor

k Modification factor depending on load duration mod k Coefficient accounting for the reduction of the process-induced prestress p k Surface treatment factor sp

3.2.3 Greek upper-case letters

ΔT Temperature change

3.2.4 Greek lower-case letters

α Coefficient of linear thermal expansion T γ Material partial factor M Partial factor for prestress on the surface γ P λA Size-effect factor area λ Size-effect factor length (edge, hole)

ν Poisson’s ratio ρ Density of glass σ Design value of principal stresses on the surface of the glass in the relevant direction prin,Ed ψ Cavity pressure combination factors cp,i

oSIST prEN 19100-1:2024 prEN 19100-1:2024 (E)

4 Basis of design

4.1 Requirements

4.1.1 Basic requirements

(1) Glass structures shall be designed in accordance with the general rules given in EN 1990. (2) In conjunction with EN 1990, the specific provisions for resistance, serviceability, durability and robustness given in this document should be used.

4.1.2 Consequence classes

(1) Considering the consequences of failure or malfunction, glass components shall be classified according to the Consequence Classes given in EN 1990:2023, Table 4.1. NOTE For glass components that are in class of consequence CC0, see EN 16612.

4.1.3 Design working life

(1) Glass components should be designed for a design working life category according to EN 1990. NOTE The design working life refers to structural design only. Other performance requirements (e.g. thermal insulation, weather tightness, etc.) or aesthetic requirements can lead to a different working life of a glass component.

(2) It is recommended to establish a maintenance concept, explicitly describing inspection measures. (3) Requirements for replaceability may be as specified by the relevant authority or, where not specified, agreed for a specific project by the relevant parties.

(4) Glass components being part of the primary structural system should correspond to the design working life of the rest of the global structure.

NOTE See also Clause 6 “Durability”.

4.2 Principles of limit state design

4.2.1 General

(1) The choice of glass is depending on the mode of breakage. Therefore, the required mode of breakage and subsequently, the choice of glass type should be clarified prior to the verification in the limit states. NOTE Further information on the choice of glass is provided in CEN/TS 19100-4. (2) Glass components should be designed for the following limit states as relevant:

...