Abstract

1.1 Scope of EN 19100-3
(1) This document gives design rules for glass components and assemblies primarily subjected to in-plane loading. It also covers effects of loads acting both in-plane and parallel to the plane produced by the neutral axes of the component, including construction rules for joints connecting in-plane loaded glass components.
1.2 Assumptions
(1) The assumptions of EN 1990-1, EN 19100-1 and EN 19100-2 apply.
(2) This document is intended to be used in conjunction with, EN 1990-1, EN 1991 (all parts), EN 1993-1-1, EN 1995-1-1, EN 1998 (all parts), EN 1999-1-1, EN 19100-1, EN 19100-2 and EN 12488.

Status
Not Published
Public Enquiry End Date
28-Nov-2024
Technical Committee
KON - Structures
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
27-Mar-2026
Due Date
15-May-2026

Buy Documents

Draft

oSIST prEN 19100-3:2024

English language (34 pages)
Preview
Preview
e-Library read for
×1 day

kSIST FprEN 19100-3:2026 is the Slovenian edition of the draft European standard for Eurocode 10, Part 3, on design of glass structures with in-plane loaded glass components. It gives design rules for glass components and assemblies mainly subjected to in-plane loading, and it is written for structural designers, manufacturers and others who need to verify strength, stability, robustness and joints in glass structures.

What does kSIST FprEN 19100-3:2026 specify?

kSIST FprEN 19100-3:2026 specifies design rules for glass components and assemblies that are primarily loaded in-plane. It also covers combined effects where loads act both in-plane and parallel to the plane through the neutral axes, and it includes construction rules for joints connecting these components.

The document is organized into 10 clauses and 3 informative annexes:

AnnexWhat it covers
Annex ACalculation of the critical buckling load and the critical bending moment
Annex BCalculation of effective moments of inertia for laminated glass
Annex CCalculation of K-values for simplified bolted splice design

Clause 4 sets the basis of design, Clause 7 covers structural analysis and detailing, Clause 8 covers ULS, FLS and PFLS, and Clause 10 covers joints and connections.

What are the key requirements of kSIST FprEN 19100-3:2026?

kSIST FprEN 19100-3:2026 focuses on safe behaviour before fracture, during fracture and after fracture. In practice, the designer has to check not only glass stress and buckling, but also robustness, load redistribution, joint behaviour and the consequences of breakage.

Basis of design, robustness and fracture scenarios

Clause 4 requires the Limit State Scenario (LSS) to follow prEN 19100-1. Fracture of any glass ply must not compromise adjacent components or lead to progressive collapse. The document expects verification in ULS, FLS and PFLS, plus attention to robustness and a second load path where needed.

For laminated glass, the shear interaction provisions from prEN 19100-1 should be used. If a ply or component fractures, the effect on the safety of adjoining structure, components and people has to be analysed and verified. A repair or replacement concept should also be provided, which matters for maintenance planning after damage.

FLS and PFLS verification

Clause 4 distinguishes between FLS and PFLS. FLS is for sudden fracture events and requires sufficient safety during fracture, while PFLS is for a limited time after fracture and can be checked either by residual resistance or by an alternative load path.

For FLS, the accidental load combination is normally used, and verification may be by test or by theoretical assessment. The theoretical route must include dynamic amplification, shift of the neutral axis after fracture, forced deformation of the remaining section, and stiffness and resistance reduction. If impact is relevant, the document allows an additional lateral impact verification with the impactor type and energy set by the relevant authority or project agreement.

For PFLS, the document requires load carrying capacity of the global system after fracture. Testing is preferred for residual resistance of in-plane loaded glass components unless an alternative load path is secured. If PFLS is assessed without testing, at least one glass ply should be assumed to remain unfractured and this assumption must be justified.

Structural analysis, imperfections and geometry

Clause 7 requires realistic structural modelling. The analysis should use nominal glass thicknesses, and single components should normally be statically determinate. If supports are non-determinate, realistic boundary conditions, including tolerances and erection stage effects, should be taken into account.

The document requires imperfections to be included in the analysis. A basic imperfection combines a length-related part and an installation-related part. For laminated glass in FLS and PFLS, the imperfection may need modification after ply fracture or after expansion of a fractured thermally toughened ply.

Second-order effects are considered when they significantly increase action effects or alter structural behaviour. Third-order analysis should be used when membrane effects are safety relevant. This matters because in-plane compression and large deformations can change the force path and the buckling resistance.

ULS, SLS and design checks

Clause 8 requires ULS verification by structural calculation. In ULS, all glass components are treated as intact. The design of in-plane loaded components must cover both glass stresses, including local stress concentrations, and buckling resistance.

Clause 9 requires SLS verification by structural calculation, or by testing. In SLS, all plies are taken as intact. For axial compression, the compressive strength may be taken equal to the tensile bending strength on the safe side.

Joints and connections

Clause 10 gives rules for sleeve bearings, lapped splices with bolts in shear, and friction connections. The document requires joint design to consider force distribution, local stress concentrations and any unfavourable effect of eccentricity or restraint.

For bolted lapped splices, the document allows numerical FE analysis or a simplified method. The simplified method uses K-values from Annex C and requires checks on hole spacing, edge distance, sleeve geometry and polymeric-modified mortar fill. For friction connections, the splice should be double-lapped, slipping is not permitted, and the effective friction coefficient must be determined by experimental assessment.

What terms does kSIST FprEN 19100-3:2026 define?

  • Fracture Limit State (FLS) - the state used to verify safety during sudden fracture, including impact cases where relevant.
  • Post Fracture Limit State (PFLS) - the state used to verify residual safety after fracture for a limited time.
  • Limit State Scenario (LSS) - the design scenario selected for the in-plane loaded glass component.
  • Second order analysis - geometrically nonlinear analysis that includes out-of-plane deflections in equilibrium.
  • Third order analysis - geometrically nonlinear analysis that includes both out-of-plane and in-plane deflections.
  • Membrane effect - the influence of in-plane deflections on stresses and sectional forces.
  • Structural redundancy - the ability of a structure to redistribute loads after damage.
  • Polymeric-modified mortar - mortar used to fill gaps between glass and other parts for force and stress transmission.

Who uses kSIST FprEN 19100-3:2026?

kSIST FprEN 19100-3:2026 is used by structural designers, façade engineers, manufacturers, constructors, relevant authorities, software developers and committees preparing related product and test standards. It is also relevant for clients and quality managers who need to confirm that an in-plane glass system has been checked for strength, buckling, fracture behaviour, joints and post-breakage safety.

In practice, users apply it to design glass beams, panes, laminated assemblies and their joints, choose analysis methods, set up testing, define National Annex choices, and document robustness and repair strategy.

What changed in kSIST FprEN 19100-3:2026 from the previous edition?

kSIST FprEN 19100-3:2026 supersedes CEN/TS 19100-3:2021. The changes stated in the document are a modified title and scope, and updated references.

Which standards are used with kSIST FprEN 19100-3:2026?

The document is intended to be used together with these standards and parts:

StandardContribution in this document
EN 1990Basis of structural and geotechnical design, including load combinations and reliability framework
EN 1991 (all parts)Actions on structures
EN 1993-1-1Steel design rules used for bolted shear design and related checks
EN 1995-1-1Timber design rules named for combined use
EN 1998 (all parts)Earthquake design rules named for combined use
EN 1999-1-1Aluminium design rules used for bolted shear design and related checks
EN 19100-1General rules and materials for Eurocode 10
EN 19100-2Out-of-plane loaded glass components and testing guidance
EN 12488Named as a companion standard for use with this part

It also refers to EN 1090-2 for bolt pre-stress application, EN 12150, EN 14179 and EN 1863 for edge and hole spacing provisions, EN ISO 12543 for laminated glass hole offset limits, and EN 16612 for guidance on laminated glass shear interaction.

What does the kSIST FprEN 19100-3:2026 document contain?

kSIST FprEN 19100-3:2026 contains the design basis for in-plane loaded glass, rules for FLS and PFLS, structural analysis methods, imperfection modelling, and detailed connection rules. It also includes table-based imperfection values, dynamic amplification guidance for fracture, and guidance on laminated glass under time and temperature effects.

The annexes provide calculation tools rather than prescriptive design rules. Annex A gives equations for critical buckling load and lateral torsional buckling moment, Annex B gives methods for effective bending and torsional inertia of laminated glass, and Annex C gives K-values used in the simplified calculation of bolted splices. These parts support hand calculation, checking of software output, and project-specific assessment.

Relations

Effective Date
09-Sep-2026
Effective Date
09-Sep-2026
Effective Date
25-Aug-2026
Effective Date
08-Jun-2022

Buy Documents

Draft

oSIST prEN 19100-3:2024

English language (34 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Aboma Certification B.V.

Specialized in construction, metal, and transport sectors.

RVA Netherlands Verified

Sponsored listings

Frequently Asked Questions

kSIST FprEN 19100-3:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Eurocode 10 - Design of glass structures - Part 3: In-plane loaded glass components". This standard covers: 1.1 Scope of EN 19100-3 (1) This document gives design rules for glass components and assemblies primarily subjected to in-plane loading. It also covers effects of loads acting both in-plane and parallel to the plane produced by the neutral axes of the component, including construction rules for joints connecting in-plane loaded glass components. 1.2 Assumptions (1) The assumptions of EN 1990-1, EN 19100-1 and EN 19100-2 apply. (2) This document is intended to be used in conjunction with, EN 1990-1, EN 1991 (all parts), EN 1993-1-1, EN 1995-1-1, EN 1998 (all parts), EN 1999-1-1, EN 19100-1, EN 19100-2 and EN 12488.

1.1 Scope of EN 19100-3 (1) This document gives design rules for glass components and assemblies primarily subjected to in-plane loading. It also covers effects of loads acting both in-plane and parallel to the plane produced by the neutral axes of the component, including construction rules for joints connecting in-plane loaded glass components. 1.2 Assumptions (1) The assumptions of EN 1990-1, EN 19100-1 and EN 19100-2 apply. (2) This document is intended to be used in conjunction with, EN 1990-1, EN 1991 (all parts), EN 1993-1-1, EN 1995-1-1, EN 1998 (all parts), EN 1999-1-1, EN 19100-1, EN 19100-2 and EN 12488.

kSIST FprEN 19100-3:2026 is classified under the following ICS (International Classification for Standards) categories: 81.040.20 - Glass in building; 91.080.99 - Other structures. The ICS classification helps identify the subject area and facilitates finding related standards.

kSIST FprEN 19100-3:2026 has the following relationships with other standards: It is inter standard links to kSIST FprEN 19100-1:2026, kSIST FprEN 19100-2:2026, SIST-TS CEN/TS 19100-4:2024, SIST-TS CEN/TS 19100-3:2022. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

kSIST FprEN 19100-3:2026 is associated with the following European legislation: Standardization Mandates: M/515. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

kSIST FprEN 19100-3:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 0 Introduction
  • 0.1 Introduction to the Eurocodes
  • 0.2 Introduction to EN 19100 (all parts)
  • 0.4 Verbal forms used in the Eurocodes
  • Annex A Annex B Annex C
  • 1 Scope
  • 1.2 Assumptions
  • 2 Normative references
  • 3 Terms, definitions and symbols
  • 3.1 Terms and definitions
  • 3.1.1 shear element made of glass
  • 3.1.2 buckling length
  • 3.1.3 second order analysis
  • 3.1.4 third order analysis
  • 3.1.5 membrane effect
  • 3.1.6 axes of a glass pane, component or member and their direction
  • 3.1.7 structural redundancy
  • 3.1.8 sudden fracture
  • 3.1.9 protection measure
  • 3.1.10 polymeric-modified mortar
  • 3.2 Symbols and abbreviations
  • 4 Basis of design
  • 4.1 Requirements
  • 4.2 Fracture limit state (FLS) verification
  • 4.3 Post fracture limit state (PFLS) verification
  • 5 Materials
  • 6 Durability
  • 7 Structural analysis and detailing
  • 7.1 Structural modelling for analysis
  • 7.2 Effects of deformed geometry of the structure
  • 7.3 Consideration of imperfections
  • 7.4 Interlayers of laminated glass
  • 7.5 Temperature effect and long-term effect
  • 7.6 Detailing
  • 8 Limit states including ULS, FLS and PFLS
  • 8.1 General
  • 8.2 Dynamic effects in FLS
  • 9 Serviceability limit states
  • 10 Joints and Connections
  • 10.1 General
  • 10.2 Sleeve bearings
  • 10.3 Lapped splices with bolts in shear
  • 10.4 Friction connections
  • Annex A
  • Annex B
  • Annex C
  • Bibliography

0 Introduction

0.1 Introduction to the Eurocodes

The Structural Eurocodes comprise the following standards generally consisting of a number of parts:

EN 1990 Eurocode — Basis of structural and geotechnical design EN 1991 Eurocode 1 — Actions on structures EN 1992 Eurocode 2 — Design of concrete structures EN 1993 Eurocode 3 — Design of steel structures EN 1994 Eurocode 4 — Design of composite steel and concrete structures EN 1995 Eurocode 5 — Design of timber structures EN 1996 Eurocode 6 — Design of masonry structures EN 1997 Eurocode 7 — Geotechnical design EN 1998 Eurocode 8 — Design of structures for earthquake resistance EN 1999 Eurocode 9 — Design of aluminium structures EN 19100 Eurocode 10 — Design of glass structures The Eurocodes are intended for use by designers, clients, manufacturers, constructors, relevant authorities (in exercising their duties in accordance with national or international regulations), educators, software developers, and committees drafting standards for related product, testing and execution standards. NOTE Some aspects of design are most appropriately specified by relevant authorities or, where not specified, can be agreed on a project-specific basis between relevant parties such as designers and clients. The Eurocodes identify such aspects making explicit reference to relevant authorities and relevant parties.

0.2 Introduction to EN 19100 (all parts)

EN 19100 (all parts) applies to the structural design of mechanically supported glass components and assemblies of glass components. It complies with the principles and requirements for the safety and serviceability of structures, the basis of their design and verification that are given in EN 1990, Basis of structural and geotechnical design.

EN 19100 is subdivided into three parts:

EN 19100-1, Eurocode 10 — Design of glass structures — Part 1: General rules EN 19100-2, Eurocode 10 — Design of glass structures — Part 2: Out-of-plane loaded glass components EN 19100-3, Eurocode 10 — Design of glass structures — Part 3: In-plane loaded glass components 0.3 Introduction to EN 19100-3 EN 19100-3 applies to the structural design of in-plane loaded glass components in conjunction with EN 19100-1 and EN 19100-2.

oSIST prEN 19100-3:2024 prEN 19100-3:2024 (E)

0.4 Verbal forms used in the Eurocodes

The verb “shall" expresses a requirement strictly to be followed and from which no deviation is permitted in order to comply with the Eurocodes.

The verb “should” expresses a highly recommended choice or course of action. Subject to national regulation and/or any relevant contractual provisions, alternative approaches could be used/adopted where technically justified.

The verb “may" expresses a course of action permissible within the limits of the Eurocodes. The verb “can" expresses possibility and capability; it is used for statements of fact and clarification of concepts. 0.5 National annex for EN 19100-3 National choice is allowed in this document where explicitly stated within notes. National choice includes the selection of values for Nationally Determined Parameters (NDPs). The national standard implementing EN 19100-1 can have a National Annex containing all national choices to be used for the design of buildings and civil engineering works to be constructed in the relevant country. When no national choice is given, the default choice given in this document is to be used. When no national choice is made and no default is given in this document, the choice can be specified by a relevant authority or, where not specified, agreed for a specific project by appropriate parties. National choice is allowed in EN 19100-1 through notes to the following clauses:

4.2.1(2) 4.2.1(5) – 2 choices 4.3.1(2) 4.3.1(3) 4.3.1(7) 7.3.2(1) 8.2(3) 10.3.1(4) – 2 choices 10.3.3(1) 10.3.4.3(2) 10.4.1(1) National choice is allowed in EN 19100-3 on the application of the following informative annexes:

Annex A Annex B Annex C

The National Annex can contain, directly or by reference, non-contradictory complementary information for ease of implementation, provided it does not alter any provisions of the Eurocodes.

oSIST prEN 19100-3:2024 prEN 19100-3:2024 (E)

1 Scope

1.1 Scope of prEN 19100-3 (1) This document gives design rules for glass components and assemblies primarily subjected to in-plane loading. It also covers effects of loads acting both in-plane and parallel to the plane produced by the neutral axes of the component, including construction rules for joints connecting in-plane loaded glass components.

1.2 Assumptions

(1) The assumptions of EN 1990, prEN 19100-1 and prEN 19100-2 apply. (2) This document is intended to be used in conjunction with, EN 1990, EN 1991 (all parts), EN 1993-1-1, EN 1995-1-1, EN 1998 (all parts), EN 1999-1-1, prEN 19100-1, prEN 19100-2 and EN 12488.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE See the Bibliography for a list of other documents cited that are not normative references, including those referenced as recommendations (i.e. through ‘should’ clauses) and permissions (i.e. through ‘may’ clauses). EN 1990, Eurocode — Basis of structural and geotechnical design prEN 19100-1:2024, Eurocode 10 — Design of glass structures — Part 1: Basis of design and materials prEN 19100-2:2024, Eurocode 10 — Design of glass structures — Part 2: Design of out-of-plane loaded glass components

3 Terms, definitions and symbols

3.1 Terms and definitions

For the purposes of this document, the terms and definitions given in prEN 19100-1 and prEN 19100-2 and the following apply.

3.1.1 shear element made of glass

glass element sustaining on purpose loads or stresses in-plane (F , F ,p , p ,) x z x z Note 1 to entry: The element may be loaded also by loading transversal to the plane (qy).

3.1.2 buckling length

system length of an otherwise similar member with pinned ends, which has the same critical buckling load as a given member or segment of member [SOURCE: EN 1993-1-1:2022, 3.1.7]

3.1.3 second order analysis

geometrically non-linear analysis taking account of the out-of-plane deflections whilst calculating equilibrium of stresses or sectional forces of a glass pane

oSIST prEN 19100-3:2024 prEN 19100-3:2024 (E)

3.1.4 third order analysis

geometrically non-linear analysis taking account of both the out-of-plane and in-plane deflections whilst calculating equilibrium of stresses or sectional forces of a glass pane

3.1.5 membrane effect

influence on stresses and sectional forces due to consideration of in-plane deflections in static equilibrium

3.1.6 axes of a glass pane, component or member and their direction

x-x in the glass pane, component or member, preferably one of the gravity lines y-y perpendicular to the glass pane, defined by the x- and the z-axes z-z in the glass pane, component or member, perpendicular to x-x Note 1 to entry: The directions of x-, y- and z-axes should accord to those of thumb (x), index finger (y) and middle finger (z) of the right hand in the defined planes, see Figure 3.1.

Note 2 to entry: When bending about the y-axis occurs this axis is also called strong axis, and accordingly, when bending about the x-axis or the z-axis these axes are called weak axes.

Figure 3.1 — Definition of axes of a glass pane, component or member and their direction

3.1.7 structural redundancy

ability of a structure to redistribute among its members/connections the loads which can no longer be carried by some other damaged portions

3.1.8 sudden fracture

fracture event of unpredictable origin

3.1.9 protection measure

measure that is intended to prevent or reduce the risk of accidental damage of a glass member that may affect its structural function

3.1.10 polymeric-modified mortar

mortar, used for filling gaps between glass and other parts for force and stress transmission Note 1 to entry: For reasons of strength and ductility, to avoid stress peaks, polymeric materials are added to the mortar.

oSIST prEN 19100-3:2024 prEN 19100-3:2024 (E)

3.2 Symbols and abbreviations

3.2.1 Latin upper-case letters

A Glass cross section area of ply i

C , C Factors taking into account different bending moments 1 2 E Modulus of elasticity for glass F Design loading on the structure Ed F Elastic critical buckling load for global instability mode based on initial elastic stiffnesses cr G Shear modulus of glass G Shear modulus of interlayer int I Moment of inertia of ply i

I Effective torsional moment of inertia T,eff I Effective moment of inertia about the minor axis (z-axis) z,eff Km Equilibrium parameter L Buckling length B L Buckling length (lateral torsional buckling) LT M The design value of the moment Ed M Critical buckling moment (lateral torsional buckling) cr,LT N Design value of normal forces in the relevant direction of the considered cross section or joint Ed N Elastic critical force for the relevant buckling mode cr P Arbitrary in-plane load P Actions having been present in the plies whose fracture is investigated fractured P Actions having been and still being present in the unfractured part of the cross section unfractured Pu Ultimate arbitrary in-plane load P Applied bolt pre-stress P,b P P Forces according to Table C.1 x,I ( x,m) S Design bolt forces b,Ed S Friction shear resistance Fr,b,Rd V Design value of the shear force Ed

oSIST prEN 19100-3:2024 prEN 19100-3:2024 (E)

3.2.2 Latin lower-case letters

b Width b Effective width m d Hole diameter

e Basic imperfection

e Considering all imperfections of the component being length related 0,length e Considering deviations coming from unplanned eccentric load introduction 0,installation e Distance of the mid-plane of two conjunct glass panels z fg,d Design bending strength according to prEN 19100-1:2024, Annex A h Glass ply thickness h Component thickness for calculation of installation eccentricity e h Thickness of ply i

h Thickness of the interlayer int h Total thickness of the laminate tot k Factors considering constructive influences for the design of bolted shear connections, {j=1, … j 10} NOTE The factors k1 to k10 are not the same as the ki factor given in prEN 19100-1:2024, Annex A. l Length of the shorter edge of the glass pane l Component length

n Number of plies p Hole distance

t Sleeve thickness sleeve v Initial lateral deflection of midplane 0,m w Deflection in z-direction w Width of the polymer or polymeric-modified mortar mortar z Distance of the i-th ply's center to center of adjacent interlayer

zp Distance between the member axis and the point where the load is applied

3.2.3 Greek upper-case letters

Δe Eccentricity shift due to fracture of a ply shift Δe Forced constraint deformation exp Θ Torsional deflection 0,m

oSIST prEN 19100-3:2024 prEN 19100-3:2024 (E)

3.2.4 Greek lower-case letters

α Factor by which the design loading would have to be increased to cause the critical elastic cr instability in terms of indifferent equilibrium λ Slenderness for torsional buckling T µ Coefficient of friction Fr μ Design value of friction coefficient Fr,d σ Maximal principal stress p,Ed σ Maximum stress for lapped splices φ,max,E Φ Dynamic load amplification factor for those actions which originate from mass inertia Φ Dynamic amplification factor mg

4 Basis of design

4.1 Requirements

(1) For an in-plane loaded glass component, the Limit State Scenario (LSS) should be chosen according to prEN 19100-1:2024, 4.2.4.

(2) The fracture of any glass plies shall neither compromise the stability or resistance of adjacent components nor result into a progressive collapse.

(3) Verification in ULS, FLS and PFLS is deemed to verify that fracture of a glass ply prevents progressive collapse.

(4) Special attention shall be paid to robustness of the structure, see prEN 19100-1 and EN 1990. (5) When ensuring sufficient robustness, depending on the function, importance and installation position (e.g. height over ground or floor resp., vertical or non-vertical), care shall be taken on the aspects as given in prEN 19100-2:2024, 4.1(3). In addition to that, sufficient redundancy by providing a second load path (background safety) on assembly level and/or structure´s level shall be ensured. (6) In case of laminated glass, the shear interaction provisions as given in prEN 19100-1:2024, 7.2.2 should be used. Guidance can be taken from prEN 19100-2:2024, Annex A or from EN 16612. (7) In case of fracture of a ply or of a component the consequences for the safety and integrity of adjoining structure, components and people shall be analysed and verified. (8) To achieve robustness a sufficient number of glass plies should be provided. NOTE Redundancy and robustness can be enhanced by a coarse crack pattern and/or further restricting boundary conditions of the glass component.

(9) A concept for the repair or replacement of in-plane loaded glass components should be provided.

4.2 Fracture limit state (FLS) verification

4.2.1 General

(1) In the FLS sufficient safety during sudden fracture shall be verified (failsafe verification). NOTE 1 For events of impact in the FLS, see 4.2.1(5).

NOTE 2 The sudden fracture can be of one or several glass plies or of one or several glass components.

oSIST prEN 19100-3:2024 prEN 19100-3:2024 (E) NOTE 3 If fracture of glass components is taken into account, then normally the number of suddenly fractured glass components is 1.

(2) In the FLS, an appropriate load combination should be used for the static loading that arises during the sudden fracture and if necessary during the event of impact, see 4.2.1(5). NOTE The load combination in the FLS is the accidental load combination according to EN 1990, unless the National Annex gives a different specification. For load combination in case of dynamic effects in the FLS, see 8.2. (3) Depending on the project specific situation also elevated temperatures e.g. due to solar absorption should be taken into account for laminated glass components, see prEN 19100-1:2024, 4.3.1. (4) In the FLS the glass component can be verified by experimental testing or alternatively, by a theoretical assessment.

NOTE Verification can include reference to previously executed tests or calculations. (5) Depending on the project, an additional energy intensive lateral impact verification perpendicular to the surface at the most unfavourable location may be conducted. The type of impactor and energy should be as specified by the relevant authority or, where not specified, agreed for a specific project by the relevant parties. NOTE 1 The National Annex can also specify type of impactor and energy. NOTE 2 Generally, further provisions for the verification in the FLS can be given in the National Annex.

4.2.2 Verification of the Fracture Limit State by testing

(1) For the verification of the FLS by experimental testing, prEN 19100-2:2024, 4.2.2 should be applied.

4.2.3 Verification of the Fracture Limit State by theoretical assessment

(1) Alternatively to 4.2.2, a theoretical assessment in the FLS may be performed. All static and dynamic effects originating from impact and/or damage/fracture of parts of the glass component or of the whole shall reasonably be taken into account for the short time of impact including:

  • dynamic amplification;
  • eccentricity shift due to fracture of a ply if laminated glass is used, see Figure 7.1;
  • forced constraint deformation on the remaining cross-section after breakage of a ply if laminated glass is used, see Figure 7.2;
  • stiffness and resistance reduction of the cross-section.

NOTE Generally, a theoretical assessment in the FLS is performed by a transient numerical simulation. (2) The applicability of the theoretical model shall be validated. NOTE Normally, the applicability of a theoretical model is validated by experimental benchmark tests. (3) To that end, the dynamic amplification effects by fracture - of one or more plies of the laminate glass component (i.e. sudden fracture out of the static rest position due to hard impact with low energy or spontaneous breakage), and - if necessary, of one or more plies of the laminate with hard lateral impact with energy, and - if necessary, of one or more glass components should be taken into account.

oSIST prEN 19100-3:2024 prEN 19100-3:2024 (E) NOTE For the amount of the dynamic amplification out of the static rest position, see 8.2. (4) If a lateral mass impact has additionally to be taken into account (lateral impact with energy), a further investigation should be carried out to determine the amount of impact energy and the resulting effective dynamic amplification factor Φ due to mass inertia.

(5) Whether a lateral mass impact needs to be taken into account should be specified by the relevant authority or, where not specified, agreed for a specific project by the relevant parties.

4.3 Post fracture limit state (PFLS) verification

4.3.1 General

(1) In the PFLS sufficient safety after fracture for a limited period of time shall be verified (verification of residual resistance of the glass component or verification of an alternative load path). The fracture may be of one or several glass plies or of one or several components.

NOTE 1 The mechanical behaviour, including the residual resistance, of the glass component in the post fracture limit state (PFLS) is influenced by the type of glass component (e.g. mode of breakage, type of interlayer, number of plies), the size of the glass component and its supporting system.

NOTE 2 If fracture of a component is taken into account then normally the number of fractured glass components is 1. (2) In the PFLS an appropriate load combination should be used. NOTE The load combination in the PFLS is the accidental load combination according to EN 1990 and prEN 19100-1 unless the National Annex gives different specification.

(3) Aspects that should be considered for the determination of the time period can originate from the following:

time to secure the environment, temporary support, time to replace, time to remove the load etc. The time limited variable actions may be reduced according to EN 1991-1-6. NOTE Post fracture time periods in the PFLS can be set by the National Annex. (4) Depending on the project specific situation compared to the ambient temperature level, elevated temperatures e.g. due to solar absorption should be taken into account for laminated glass components for assessment in PFLS.

(5) In the PFLS the glass component can be verified by experimental testing or alternatively by a theoretical assessment.

(6) The verification of the residual resistance of in plane loaded glass components for PFLS should be verified by testing only. If an alternative load path is ensured, then the verification of the residual resistance for PFLS may be neglected.

NOTE Verification can include reference to previously executed tests. (7) In PFLS, the load carrying capacity of the global system shall be verified taking into account the fracture of glass components. The number of fractured glass components in the global structure should be assessed based on the specific design situation, see 4.3.1(1), unless it is as agreed for a specific project by the relevant parties. NOTE Generally, further provisions for the verification in the PFLS can be given in the National Annex.

...