Status
Not Published
Public Enquiry End Date
30-Sep-2025
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
10-Nov-2026
Due Date
29-Dec-2026
Completion Date
20-Nov-2026

Buy Documents

Draft

oSIST prEN IEC 63452:2025 - BARVE

English language (283 pages)
Preview
Preview
e-Library read for
×1 day

kSIST FprEN IEC 63452:2026 is a SIST standard on railway applications cybersecurity. It specifies a consistent approach for managing cybersecurity in railway systems, including railway networks, urban transport, maglev transport, rolling stock, fixed installations, and operational management systems. It is intended for railway duty holders, asset owners, system integrators, maintenance service providers, and product suppliers who need to define, assess, design, assure, operate, and maintain cybersecurity for railway applications.

What does kSIST FprEN IEC 63452:2026 specify?

kSIST FprEN IEC 63452:2026 specifies how to manage cybersecurity for railway applications across the railway system and its operational environment. It adapts the IEC 62443 series to the railway domain and covers cybersecurity management, zoning, risk management, supply chain management, cybersecurity requirements, cybersecurity assurance, and operational, maintenance, and decommissioning requirements.

The document also gives guidance for legacy systems and for coordinating cybersecurity activities with the railway RAMS life cycle in IEC FDIS 62278-1:2024. It does not provide safety requirements or safety case constraints, but it does address the relationship between cybersecurity and safety.

Clause 1 defines the scope, clause 2 has no normative references, clause 3 covers terms, abbreviations, taxonomy, and terms equivalence, and clauses 4 to 10 cover the main lifecycle topics. The annexes add design guidance, examples, and supporting material.

AnnexWhat it covers
Annex AConduits and protection profiles for conduits
Annex BHandling legacy systems, including risks, process activities, and countermeasures
Annex CCybersecurity design principles and guidance for implementation in a railway environment
Annex DSafety and cybersecurity
Annex ERisk acceptance methods, with worked examples
Annex FDesign guidance for system models, zone models, and train to ground communication
Annex GExample contents of key cybersecurity deliverables
Annex HCybersecurity competence profiles
Annex IAccess strategy, remote maintenance, data protection, portable media, and key exchange
Annex JVulnerability management and remediation
Annex KCloud security across the railway application life cycle

What are the key requirements of kSIST FprEN IEC 63452:2026?

Clause 4 - describe the railway system from a cybersecurity point of view

Clause 4 requires a clear cybersecurity-oriented description of the railway system. It asks the railway duty holder to identify the railway system, the subsystems that make it up, their physical or topological distribution, and a high-level railway zone model.

In practice, this matters because cybersecurity work starts with knowing what is in scope and how it is connected. Clause 4 also addresses shared cybersecurity services within the railway system, so teams can see which protections are common and which are local to a particular application or solution.

Clause 5 - run cybersecurity as an organizational programme

Clause 5 sets out enterprise cybersecurity programme and management requirements for OT systems. It calls for a railway OT cybersecurity policy, a railway OT cybersecurity programme, and documented processes for information sharing, competency management, inventory management, supply chain management, risk management, business continuity management, and data protection management.

This is the organizational layer that sits above a single project. It matters in practice because cybersecurity activities need to work before, during, and after a project, and different organizations - asset owner, system integrator, and maintenance service provider - may each own part of the work.

Clause 6 - align cybersecurity with the railway application life cycle

Clause 6 requires cybersecurity activities to be managed through the railway application life cycle and coordinated with IEC FDIS 62278-1:2024. It covers the management of cybersecurity activities and interfaces, and it maps those activities to life cycle phases and deliverables.

The document distinguishes between the railway application life cycle and the product life cycle. That separation matters because product suppliers may use their own secure development standards, while the railway application still needs the security interfaces, deliverables, and handover evidence needed for operation.

Clause 7 - assess risk by zones and conduits

Clause 7 adapts the IEC 62443-3-2 risk assessment approach to railways. It starts by identifying the system under consideration (SUC) and its security context, then partitions the SUC into zones and conduits, compares the risks, performs a detailed risk assessment, documents cybersecurity requirements, and ends with asset owner approval.

Clause 7 allows three ways to address a threat: use a code of practice, compare with a reference system, or perform explicit risk evaluation. In practice, this lets teams choose the method that fits the system and the threat, but the result still has to be a documented cybersecurity requirements specification.

Clause 8 - turn risk results into architecture and configuration

Clause 8 defines the SUC cybersecurity functional architecture, the apportionment of cybersecurity requirements to subsystems and components, and the integration and configuration requirements. It includes traceability of requirements, inclusion of compensating countermeasures, and cybersecurity guidelines for the railway solution.

This is where the risk work becomes an implementable design. The clause matters because security requirements must be assigned to real subsystems and settings, and the resulting architecture must not adversely affect essential functions.

Clause 9 - verify, validate, and accept the railway solution

Clause 9 covers cybersecurity assurance, including verification and validation and railway solution acceptance. The main input is the cybersecurity requirements specification together with the identified security-related application conditions, and the main output is the railway solution cybersecurity case.

That case collects the assurance evidence needed for handover. In practice, this gives the asset owner a documented basis for deciding whether the railway solution is ready for operational use.

Clause 10 - keep security working in operation and retirement

Clause 10 covers operational, maintenance, and decommissioning requirements. It includes a cybersecurity maintenance plan, continuous verification, an updated cybersecurity case, risk assessment updates, vulnerability management, patch management, incident management, security monitoring, and decommissioning management.

This clause matters because railway cybersecurity is not finished at handover. The document expects security to be maintained throughout operation and changed with the same discipline used during design and acceptance.

Annexes A, C, E, F, G, H, I, J, and K - practical guidance and examples

The annexes add supporting material that helps implement the main clauses. Annex A explains conduit types and protection profiles. Annex C gives cybersecurity design principles such as defence in depth, least privilege, secure defaults, and secure metadata. Annex E provides example risk acceptance methods, including impact and likelihood assessments and a likelihood calculation formula. Annex F expands the zone model with examples, including landside, rolling stock, and train to ground communication. Annex G gives example contents for deliverables, Annex H gives competence profiles, Annex I covers access and maintenance topics, Annex J covers vulnerability management, and Annex K covers cloud security through the life cycle.

What terms does kSIST FprEN IEC 63452:2026 define?

  • System under consideration (SUC) - the railway solution or part of the railway system that is being defined, designed, assessed, and protected for cybersecurity.
  • Cybersecurity requirements specification (CRS) - the document that records the cybersecurity requirements derived from the risk assessment and used for design and assurance.
  • Security-related application conditions (SecRACs) - conditions that must be met in operation or use so the cybersecurity measures remain valid.
  • Operational technology (OT) - the systems and equipment used to operate the railway application in its operating environment.
  • Cybersecurity management system (CSMS) - the organized set of processes used to manage cybersecurity activities and controls.
  • Asset owner (AO) - the organization responsible for the railway asset and for key decisions such as acceptance.
  • Defence in depth - a layered security approach that uses several independent methods so that one control does not stand alone.

Who uses kSIST FprEN IEC 63452:2026?

Railway duty holders and asset owners use this standard to define security policy, set risk criteria, approve residual risk, and accept the railway solution. System integrators use it to build the zone and conduit model, define the cybersecurity architecture, generate the CRS, and prepare the cybersecurity case.

Maintenance service providers use it for the cybersecurity maintenance plan, vulnerability handling, patching, incident response, and decommissioning. Product suppliers use it to understand the railway interface with their own secure development and assurance activities. It is relevant to railway networks, metros, tramways, trolleybuses, fully automated transport systems, and magnetic levitated transport systems.

What changed in kSIST FprEN IEC 63452:2026 from the previous edition?

The cover note states that this A version shows aligned Word extraction from the OSD for annexes and figures, the closing date for voting was extended to 2025-10-17, and no technical modification has been made. The Slovene standard is identified as identical with prEN IEC 63452:2025.

Which standards are used with kSIST FprEN IEC 63452:2026?

kSIST FprEN IEC 63452:2026 has no normative references, but it explicitly uses and adapts several related standards:

StandardWhat it contributes
IEC 62443 seriesThe main cybersecurity framework adapted to the railway domain
IEC 62443-3-2:2020Basis for the railway risk assessment process in Clause 7
IEC 62443-3-3:2013/COR1:2014Basis for the foundational cybersecurity requirements and design guidance in Annex C
IEC 62443-4-1:2018Secure development life cycle guidance for product suppliers
IEC 62443-4-2:2019/COR1:2022Companion requirements for products and component security
IEC FDIS 62278-1:2024RAMS life cycle used for coordinating cybersecurity activities
IEC 62290-1:2014Example of a railway system description approach for urban rail transport
NIST SP 800-218, NIST SP 800-82, NIST SP 800-160 Vol1Examples of other standards or frameworks product suppliers may use

What does the kSIST FprEN IEC 63452:2026 document contain?

The document contains a structured set of clauses, figures, tables, and annexes that support cybersecurity work across the railway life cycle. Figures show the railway system taxonomy, IT and OT segregation, area-based and topology-based models, a high-level zone model, the cybersecurity management system, the V-cycle, and risk assessment flowcharts.

Annex E includes example risk acceptance methods, including matrices and a likelihood formula. Annex C includes a large table that adapts IEC 62443-3-3 requirements to the railway context, while Annex G gives example contents for the main deliverables such as the cybersecurity management plan, risk assessment report, CRS, cybersecurity guidelines, evaluation plan, cybersecurity case, and maintenance plan.

Relations

Effective Date
13-Oct-2026
Effective Date
05-Aug-2025

Buy Documents

Draft

oSIST prEN IEC 63452:2025 - BARVE

English language (283 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

Bureau Veritas

Bureau Veritas is a world leader in laboratory testing, inspection and certification services.

COFRAC France Verified

DNV

DNV is an independent assurance and risk management provider.

NA Norway Verified

Sponsored listings

Frequently Asked Questions

kSIST FprEN IEC 63452:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Railway applications - Cybersecurity". This standard covers: Railway applications - Cybersecurity

Railway applications - Cybersecurity

kSIST FprEN IEC 63452:2026 is classified under the following ICS (International Classification for Standards) categories: 35.030 - IT Security; 45.020 - Railway engineering in general. The ICS classification helps identify the subject area and facilitates finding related standards.

kSIST FprEN IEC 63452:2026 has the following relationships with other standards: It is inter standard links to SIST EN 50159:2026, SIST-TS CLC/TS 50701:2024. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

kSIST FprEN IEC 63452:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions, abbreviated terms and acronyms, taxonomy and
  • 3.1 Terms and definitions
  • 3.1.1 acceptance
  • 3.1.2 access
  • 3.1.3 access control
  • 3.1.4 access control
  • 3.1.5 access point
  • 3.1.6 access point name
  • 3.1.7 accident
  • 3.1.8 achieved security level
  • 3.1.9 actively exploited vulnerability
  • 3.1.10 air gapped network
  • 3.1.11 approval
  • 3.1.12 asset owner
  • 3.1.13 attack
  • 3.1.14 attack surface
  • 3.1.15 attack vector
  • 3.1.16 audit
  • 3.1.17 authentication
  • 3.1.18 authorization
  • 3.1.19 automatic train operation
  • 3.1.20 automatic train protection system
  • 3.1.21 availability
  • 3.1.22 balise
  • 3.1.23 base transceiver station
  • 3.1.24 bridge control system
  • 3.1.25 capability security level
  • 3.1.26 central diagnostic system
  • 3.1.27 closed-circuit television
  • 3.1.28 cloud computing
  • 3.1.29 code of practice
  • 3.1.30 communication channel
  • 3.1.31 communication path
  • 3.1.32 communication based train control
  • 3.1.33 communication system
  • 3.1.34 compensating countermeasure
  • 3.1.35 component
  • 3.1.36 compromise
  • 3.1.37 conduit
  • 3.1.38 confidentiality
  • 3.1.39 control network
  • 3.1.40 control system
  • 3.1.41 countermeasure
  • 3.1.42 cybersecurity
  • 3.1.43 cybersecurity assurance
  • 3.1.44 cybersecurity case
  • 3.1.45 cyber-critical asset
  • 3.1.46 data diode
  • 3.1.47 defence in depth
  • 3.1.48 demilitarized zone
  • 3.1.49 denial of service
  • 3.1.50 digital signature
  • 3.1.51 driver advisory system
  • 3.1.52 driver machine interface
  • 3.1.53 encryption
  • 3.1.54 entertainment system
  • 3.1.55 essential function
  • 3.1.56 exploitable vulnerability
  • 3.1.57 facility management system
  • 3.1.58 fire protection system
  • 3.1.59 fixed installation
  • 3.1.60 firewall
  • 3.1.61 future railway mobile communication system
  • 3.1.62 gateway
  • 3.1.63 global system for mobile communications railway
  • 3.1.64 handover
  • 3.1.65 host
  • 3.1.66 host device
  • 3.1.67 industrial automation and control systems
  • 3.1.68 impact
  • 3.1.69 incident
  • 3.1.70 infrastructure as a service (IaaS)
  • 3.1.71 information security management system
  • 3.1.72 information technology
  • 3.1.73 integrity
  • 3.1.74 intercom call
  • 3.1.75 interlocking

Introduction

Purpose This document is an international standard (IS) that addresses cybersecurity within the railway sector. It covers all domains within the scope of the IEC TC9, including rolling stock, fixed installations, management systems (including supervision, information, communication, signalling and processing systems) for railway networks (including highspeed lines, mainlines and freight lines), metropolitan transport networks (including metros, tramways, trolleybuses and fully automated transport systems) and magnetic levitated transport systems. This document is railway-specific adaptation of the IEC 62443 series of standards, offering a set of cybersecurity requirements and guidances for every stage of a railway applications life cycle, from its creation to operation and maintenance.

This standard includes:

  • requirements for the system integrator during the development and deployment of a new railway solution, ensuring adequate cybersecurity measures are implemented;
  • requirements for the railway duty holder, asset owner, and maintenance service provider to maintain the established level of cybersecurity of railway application during the operation and maintenance phases; and
  • requirements related to the management of product suppliers. Overview of the structure of this document An overview of the document structure is given in Figure 1. In this overview, only main clauses or annexes providing requirements or guidance are shown. The elements of Figure 1 do not prescribe an execution sequence of the individual topics.

oSIST prEN IEC 63452:2025

100*200

Figure 1 – Overview of this document

oSIST prEN IEC 63452:2025

1 Scope

This document provides a consistent approach to manage cybersecurity of railway applications in a railway system. It is applicable across all domains within the scope of IEC TC 9, which includes railway networks (including highspeed lines, mainlines, and freight-lines), urban transport networks (including metros, tramways, trolleybuses, and fully automated transport systems), and magnetic levitated transport systems. It includes rolling stock, fixed installations, operational management systems (including supervision, information, communication, signalling, and processing systems) for railway operation.

This document refers and adapts the relevant part of the IEC 62443 series of standards to the railway domain, detailing the cybersecurity management, zoning, risk management, supply chain management, cybersecurity requirements, cybersecurity assurance, as well as operational, maintenance, and decommissioning requirements. It outlines the cybersecurity activities and cybersecurity deliverables needed to identify, monitor, and manage cybersecurity risks within a railway application life cycle and in its operational environment (railway system) to a level tolerable by the railway duty holder. It also provides guidance on how to secure legacy system.

Furthermore, this document provides guidance on coordinating and synchronising the cybersecurity activities with the generic reliability, availability, maintainability, and safety (RAMS) life cycle defined in IEC FDIS 62278-1:2024, and provides criteria for application to other life cycles.

Lastly, while this document does not provide safety requirements or constraints on the safety case for railway applications, it does offer guidance on the relationship between cybersecurity and safety.

2 Normative references

There are no normative references in this document.

3 Terms and definitions, abbreviated terms and acronyms, taxonomy and

terms equivalence

3.1 Terms and definitions

For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses:

  • IEC Electropedia: available at http://www.electropedia.org/
  • ISO Online Browsing Platform: available at http://www.iso.org/obp

3.1.1 acceptance

<for a product, system or process> status achieved by a product, system or process once it has been agreed that it is suitable for its intended purpose [SOURCE: IEC FDIS 62278-1:2024, 3.1]

3.1.2 access

<in cybersecurity> ability and means to communicate with or otherwise interact with a system in order to use system resources

oSIST prEN IEC 63452:2025

Note 1 to entry: Access can involve physical access (authorization to be allowed physically in an area, possession of a physical key lock, PIN code, or access card or biometric attributes that allow access) or logical access (authorization to log in to a system and application, through a combination of logical and physical means).

3.1.3 access control

<protection> protection of system resources against unauthorised access [SOURCE: IEC 62443-4-1:2018 [49], 3.1.2]

3.1.4 access control

<process> process by which use of system resources is regulated according to a security policy and is permitted by only authorized entities (users, programs, processes, or other systems) according to that policy Note 1 to entry: Access control includes identification and authentication requirements specified in other parts of the IEC 62443 series of standards.

[SOURCE: IEC 62443-4-1:2018 [49], 3.1.3, modified – "users" replaced by "entities (users, programs, processes, or other systems)"]

3.1.5 access point

in a network, a point at which the user may connect to the network [SOURCE: IEV 732-01-16]

3.1.6 access point name

APN name of a gateway between a mobile network (GSM, GPRS, 3G, 4G and 5G) and another computer network, frequently the public Internet.

3.1.7 accident

unintended event or series of events that results in death, injury, loss of a system or service, or environmental damage [SOURCE: IEC FDIS 62278-1:2024, 3.2]

3.1.8 achieved security level

SL-A actual security level provided during the operation of a railway application Note 1 to entry: SL-A is used to describe the security level of a zone or conduit when all technical, physical and process security measures are in place. SL-A is determined during the operation and maintenance phase of the railway application. They are used to establish that a security system is meeting the goals that were originally set out in the SL-Ts.

[SOURCE: ISA-62443-1-1 (May 2024) 8.6.3, modified –"IACS" replaced by "railway application", zone and conduit added]

3.1.9 actively exploited vulnerability

vulnerability for which there is reliable evidence that a malicious actor has exploited it in a system without permission of the system owner

oSIST prEN IEC 63452:2025

3.1.10 air gapped network

network which is physically and logically isolated in a way that no external unit, e.g. used for a cyber-attack, exchange information with any internal unit of this network Note 1 to entry: It is possible to exchange data with such an air gapped network via a dedicated interface, e.g. mobile storage devices (USB stick).

3.1.11 approval

permission for a product or process to be marketed or used for stated purposes or under stated conditions Note 1 to entry: Approval can be based on fulfilment of specified requirements or completion of specified procedures.

[SOURCE: IEV 902-06-01]

3.1.12 asset owner

AO individual or organization responsible for one or more railway applications Note 1 to entry: An asset owner belongs to a railway duty holder (RDH) organization, and applies the OT cybersecurity policy defined by its RDH organization.

[SOURCE: IEC 62443-4-1:2018,3.1.6, modified - "IACS" replaced by "railway application", note 1 to entry added]

3.1.13 attack

attempt to gain access to an information processing system or operational technology system in order to produce damage Note 1 to entry: The damage can be, for example, destruction, disclosure, alteration, disruption, and unauthorised use.

[SOURCE: IEV 171-08-12, modified – “or operational technology system” added, “disruption” added in the note 1 to entry]

3.1.14 attack surface

physical and functional interfaces of a system that can be accessed and through which the system can be potentially exploited Note 1 to entry: The size of the attack surface for a software interface is proportional to the number of methods and parameters defined for the interface. Simple interfaces, therefore, have smaller attack surfaces than complex interfaces.

Note 2 to entry: The size of the attack surface and the number of vulnerabilities are not necessarily related to each other.

[SOURCE: IEC 62443-2-4:2023 3.1.2]

3.1.15 attack vector

method or means by which an attacker can gain access to the system under consideration in order to deliver a payload or achieve malicious outcome Note 1 to entry: Attack vectors enable attackers to exploit the vulnerabilities of the system under consideration, including the human element.

oSIST prEN IEC 63452:2025

Note 2 to entry: Attack vectors continuously evolve. Examples of attack vectors include but are not limited to USB key, e-mail attachment, wireless connection, compromised credentials, phishing and man in the middle attacks.

3.1.16 audit

systematic, independent, documented process for obtaining records, statements of fact or other relevant information and assessing them objectively to determine the extent to which specified requirements are fulfilled [SOURCE: IEV 902-03-04, modified - Note 1 to entry has been removed]

3.1.17 authentication

provision of assurance that a claimed characteristic of an identity is correct Note 1 to entry: Not all credentials used to authenticate an identity are created equally. The trustworthiness of the credential is determined by the configured authentication mechanism. Hardware or software-based mechanisms can force users to prove their identity before accessing data on a device. A typical example is proving the identity of a user usually through an identity provider.

Note 2 to entry: Authentication is usually a prerequisite to allowing access to resources in a control system. [SOURCE: IEC 62443-4-1:2018, 3.1.9]

3.1.18 authorization

<in cybersecurity> right or a permission that is granted to a system entity to access a system resource [SOURCE: IEC/TR 62443-3-1:2009, 3.1.7]

3.1.19 automatic train operation

ATO method of operation in which the movement of the train is automatically controlled without the intervention of a driver, who, if provided, exercises only a supervisory function Note 1 to entry: Can also be used to name the subsystem implementing automatic train operation [SOURCE: IEV 821-09-01, modified – Note 1 to entry added]

3.1.20 automatic train protection system

ATP system using information of signal aspects, track speed limits, train speed supervision and driver reactions to prevent automatically a train passing a danger point (such as a signal at danger) or exceeding speed restrictions [SOURCE: IEV 821-08-01]

3.1.21 availability

ability to be in a state to perform as required under given conditions [SOURCE: IEV, 192-01-23, modified – The notes to entry have been omitted]

3.1.22 balise

<signalling> device mounted on the track, which communicates with a train passing over it, transmitting and/or receiving signals over the air

oSIST prEN IEC 63452:2025

3.1.23 base transceiver station

BTS <in railway system> piece of equipment that facilitates wireless communication between train or passenger equipment and a network Note 1 to entry: Train or passenger equipment are devices like mobile phones, computers with wireless Internet connectivity, cab radio, or antennas mounted on train.

3.1.24 bridge control system

<in railway system> railway related infrastructure that includes the electronics installed in railway bridges to support bridge specific infrastructure functions (e.g. monitoring systems and lift control)

3.1.25 capability security level

SL-C security level that components or systems can provide when properly configured Note 1 to entry: These levels state that a particular component or system is capable of meeting the SL-Ts natively without additional compensating countermeasures when properly configured and integrated. [SOURCE: SOURCE: 62443 3-2:2020 Annex A]

3.1.26 central diagnostic system

onboard component that centralises all diagnostic messages and signals from other train devices and subsystems

3.1.27 closed-circuit television

CCTV television allowing the transmission of images over a relatively short distance, generally by cable, intended for a particular group of users EXAMPLE Surveillance of public places or of places which are dangerous or difficult to access such as tunnels and inside traction sub-stations.

[SOURCE: IEV 723-01-19, example modified - “surgical operation, etc.” replaced by “such as tunnels, inside traction sub-stations“]

3.1.28 cloud computing

paradigm for enabling network access to a scalable and elastic pool of shareable physical or virtual resources with self-service provisioning and administration on-demand [SOURCE: ISO/IEC 17788:2014, 3.2.5]

3.1.29 code of practice

CoP document that recommends practices or procedures for the design, manufacture, installation, maintenance or utilisation of equipment, structures or products - IEC 62280 - ANSSI protection profiles - OWASP Top Ten - CIS benchmarks - NIST SP 800-160vol1 Secure Design principles;

oSIST prEN IEC 63452:2025

  • MITRE ATT&CK knowledge base Note 1 to entry: A code of practice may be a standard, a part of a standard or independent of a standard. Note 2 to entry: In the context of a risk assessment, a CoP means a written set of rules that can be used to address a set of threats.

[SOURCE: ISO/IEC Guide 2:2004, 3.5, modified – Note 2 entry added, Example added]

3.1.30 communication channel

<in cybersecurity> specific logical or physical communication link between assets Note 1 to entry: A channel facilitates the establishment of a connection. [SOURCE: IEC 62443-3-3:2019, 3.1.9]

3.1.31 communication path

physical and logical connection between a source and one or more destinations, which could be devices, physical processes, data items, commands, or programmatic interfaces Note 1 to entry: The communication path is not limited to wired or wireless networks, but includes other means of communication such as memory, procedure calls, state of physical plant, portable media, and human interactions.

3.1.32 communication based train control

CBTC continuous automatic train control system utilizing high-resolution train location determination, independent of track circuits; continuous, high capacity, bidirectional train-towayside data communications; and train-borne and wayside processors capable of implementing vital functions [SOURCE: IEEE 1474-1:2004, 3.1.13]

3.1.33 communication system

<in railway system> system to communicate with either railway equipment (e.g. GSM-R, 1, Wi- Fi), or personnel (e.g. TETRA, VoIP) or passengers (e.g. Public Announcement)

3.1.34 compensating countermeasure

countermeasure employed in lieu of or in addition to inherent security capabilities to satisfy one or more security requirements - (component-level): locked cabinet around a controller that does not have sufficient cyber access control countermeasures - (control system/zone-level): physical access control (guards, gates and guns) to protect a control room to restrict access to a group of known personnel to compensate for the technical requirement for personnel to be uniquely identified by the railway application - (component-level): a vendor’s programmable logic controller (PLC) cannot meet the access control capabilities from an end-user, so the vendor puts a hardware-based firewall in front of the PLC and sells it as a system. [SOURCE: IEC 62443-4-2:2019, 3.1.9, modified – “IACS” replaced by “railway application”, “hardware-based” added]

3.1.35 component

<in railway cybersecurity> entity belonging to a railway solution that exhibits the characteristics of one or more of a host device, network device, software application, or embedded device [SOURCE: IEC 62443-4-2:2019, 3.1.10, modified – “IACS” replaced by “railway solution”]

oSIST prEN IEC 63452:2025

3.1.36 compromise

unauthorized disclosure, modification, substitution, or use of information (including plaintext cryptographic keys and other critical security parameters) [SOURCE: 62443-1-1:2009 3.1.26]

3.1.37 conduit

<in cybersecurity> logical grouping of communication channels, connecting two or more zones, that share common security requirements Note 1 to entry: A conduit is allowed to traverse a zone as long as the security of the channels contained within the conduit is not impacted by the zone.

[SOURCE: IEC 62443-4-2:2019, 3.1.11]

3.1.38 confidentiality

<in cybersecurity> assurance that information is not disclosed to unauthorized individuals, processes, or devices Note 1 to entry: When used in the context of a railway application, confidentiality refers to protecting railway application data and information from unauthorised access.

[SOURCE: IEC 62443-4-2:2019, 3.1.12, modified – “IACS” replaced by “railway application” in Note 1 to entry]

3.1.39 control network

network, often time-critical and/or safety critical, that is typically connected to equipment that controls physical processes Note 1 to entry: The control network can be subdivided into zones and there can be multiple separate control networks within one company or site.

[SOURCE: IEC 62443-1-1:2009 3.2.21, modified – "often" and "and/or safety critical" added]

3.1.40 control system

<Railway cybersecurity> integrated set of hardware and software components of a railway application performing control function(s) within a railway solution Note 1 to entry: Control systems can be composed of field devices, embedded control devices, network devices, and host devices, including workstations and servers.

3.1.41 countermeasure

action, device, procedure, or technique that reduces a threat, a vulnerability, or an attack by eliminating or preventing it, by minimising the harm it can cause, or by discovering and reporting it so that corrective action can be taken Note 1 to entry: The term “control” is also used to describe this concept in some contexts. The term "countermeasure" has been chosen for this standard to avoid confusion with the term “control” in the context of “process control” and “control system”.

[SOURCE: IEC 62443-3-3:2013, 3.1.17]

3.1.42 cybersecurity

security

oSIST prEN IEC 63452:2025

actions required to preclude unauthorized use of, denial of service to, modifications to, disclosure of, or damage to systems or informational assets Note 1 to entry: Cybersecurity includes the concepts of indentification, authentication, accountability, authorization, availability, and privacy.

[SOURCE: 62443-1-1 3.1.40 (may 2024)]

3.1.43 cybersecurity assurance

<In railway cybersecurity> grounds for confidence that the set of intended cybersecurity controls/countermeasures in a railway application are effective in their application and that an entity meets its security objectives [SOURCE: NIST SP 800-39, amended, “information system” replaced by “railway application”, "security" by "cybersecurity"]

3.1.44 cybersecurity case

documented demonstration, at a given point in time, that the railway product, railway solution or railway application properly addresses cybersecurity risks and that appropriate design, operation processes and organization have been implemented to achieve tolerable level of cybersecurity risks Note 1 to entry: The cybersecurity case can exist at different levels:

  • "Product cybersecurity case ", as provided by the Product Supplier
  • "Railway solution cybersecurity case", as provided by the System Integrator
  • "Railway application cybersecurity case", as maintained by the Asset Owner.

...