Abstract

IEC 60079-35-2:2011 details those performance and other safety features of caplights, including those with a point of connection for another equipment, not covered in IEC 60079-35-1, but which are important for the safety and working conditions of the user. It may also be applied to caplights for use in mines not likely to be endangered by firedamp. This first edition of IEC 60079-35-2 cancels and replaces the second edition (2005) of IEC 62013-2 published in 2005 and constitutes a full technical revision. The general revision and updating of Edition 2 of IEC 62013-2 has been necessitated by the advent of new technologies related to caplight design, in particular those related light-emitting diode (LED) light sources. It is intended that there should be a stronger link between Part 1 (Construction) and Part 2 (Performance) of this Standard by upgrading the reference in the Scope of part 1 from a note to a requirement. In addition as this Standard is now to become one of the IEC 60079 series, changes have been made to bring it more in line with others in the series by cross referencing. This has enabled there to be a reduction in the number and length of clauses in the Standard.

Status
Published
Publication Date
23-Sep-2012
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
30-Aug-2012
Due Date
04-Nov-2012
Completion Date
24-Sep-2012

Buy Documents

Standard

SIST EN 60079-35-2:2012

English language (15 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN 60079-35-2:2012 is the Slovenian national standard for caplights used in mines susceptible to firedamp, identical to EN 60079-35-2:2012 and IEC 60079-35-2:2011. It specifies performance and other safety-related matters for caplights, including caplights with a point of connection for other equipment, so manufacturers, mine operators and testers can judge whether the lamp is suitable for use and routine checking. The document is the performance companion to IEC 60079-35-1, which covers construction and explosion-risk testing.

What does SIST EN 60079-35-2:2012 specify?

SIST EN 60079-35-2:2012 covers the performance and safety features of caplights that are not covered in IEC 60079-35-1 but matter for user safety and working conditions. It also says the standard may be applied to caplights for mines not likely to be endangered by firedamp.

The document is organized into:

  • Clause 1 Scope
  • Clause 2 Normative references
  • Clause 3 Terms and definitions
  • Clause 4 Light output
  • Clause 5 Reliability
  • Clause 6 Ergonomics
  • Clause 7 Type tests - Illumination throughout the useful working period
  • Clause 8 Instructions
  • Clause 9 Marking
  • Annex A, informative, with examples of routine testing by the user

Annex A also includes a typical photometric sphere drawing and a table for recording test results.

What are the key requirements of SIST EN 60079-35-2:2012?

Light output

SIST EN 60079-35-2:2012 requires the headpiece to have at least two light sources, with one main source meeting the standard. A single non-filament source is allowed if it meets the lamp life requirement. In practice, this means the caplight must still give usable light if one source is only auxiliary or if a single LED-type source is used.

The main beam must point 10 degrees, plus or minus 5 degrees, down from the horizontal when the caplight is worn normally. At the end of the useful working period, the main light must still provide the required cone of light, with a minimum of 1 cd in the defined field and a maximum illumination of at least 1 500 cd at 1 m. This matters because the wearer needs a predictable beam pattern at the end of a shift.

For non-filament sources, the colour correlated temperature (CCT) must be greater than 5 000 K and the colour rendering index (CRI) greater than 70, unless the manufacturer specifies other values in the instructions. That helps users compare LED-based caplights and understand the light quality they will get.

Reliability and ergonomics

Clause 5 sets life expectations for filament and non-filament sources, including minimum lives for main and auxiliary sources and a 5 000 h life for a single non-filament source. The caplight also has to keep meeting the light-output requirement after the stated life. Battery cyclic life is not fixed; instead, the manufacturer must tell the user the recharge time and routine checks needed for safe use.

Clause 6 addresses practical use in the mine. The battery and container mass, the total caplight mass, switch accessibility, maintainability, and headpiece security are all covered. The caplight must not be too heavy, must be easy to switch on while worn, must allow user-replaceable parts to be reached, and must provide a tether for helmet-mounted units where required.

Type testing, instructions and marking

Clause 7 gives the type test for illumination throughout the useful working period. The test uses a darkened room or enclosure at 23 °C plus or minus 2 °C, a fully charged battery, and a calibrated photometric setup at 1 000 mm. This is the proof test for the declared useful working period.

Clause 8 requires a manual with safe use, useful working period, minimum illumination, permitted light source types, user checks, user-replaceable parts, special tools, battery disposal instructions, and any non-standard CCT/CRI values.

Clause 9 requires marking with the manufacturer name or trademark, type identification, the standard number, and a date or code for battery container or cells.

What terms does SIST EN 60079-35-2:2012 define?

  • Useful working period - the manufacturer-declared time, in hours, during which the main light source can run continuously and still meet the minimum luminous intensity requirement.
  • Main light source - the source that carries the principal lighting duty and has to meet the performance requirements of the standard.
  • Auxiliary light source - a secondary source intended mainly for emergency use if the main source fails.
  • Colour correlated temperature (CCT) - the colour characteristic of a non-filament source, used here to control the whiteness of the light.
  • Colour rendering index (CRI) - a measure of how well the light shows colours, used here for non-filament sources.
  • Caplight - a lamp assembly worn on a helmet or cap for mining work.
  • Firedamp - mine gas hazards that make explosive atmospheres a concern.

Who uses SIST EN 60079-35-2:2012?

Caplight manufacturers use this standard to design light output, life, ergonomics, instructions and marking. Mining operators and mine safety staff use it when selecting lamps, setting recharge and inspection routines, and checking whether a caplight remains suitable during service.

Testing laboratories and certification bodies use it for type testing, photometric measurement and review of declarations. Quality managers and buyers use it to compare products on beam pattern, endurance, mass, maintenance access and user information.

What changed in SIST EN 60079-35-2:2012 from the previous edition?

SIST EN 60079-35-2:2012 supersedes EN 62013-2:2006, and IEC 60079-35-2:2011 replaces IEC 62013-2:2005. The revision is described as a full technical update, driven especially by LED light-source technology. It also strengthens the link with Part 1 and aligns the document more closely with the IEC 60079 series through cross-referencing.

Which standards are used with SIST EN 60079-35-2:2012?

  • IEC 60050-845 - provides lighting vocabulary used for the terms in the standard.
  • IEC 60983 - covers miniature lamps and is used for filament lamp requirements.
  • IEC 60079-35-1 - gives the construction and explosion-risk requirements for caplights and is the main companion part.
  • ISO 80000-1 - provides the general quantities and units used in the definitions and measurements.

What does the SIST EN 60079-35-2:2012 document contain?

The document contains a photometric performance requirement for the beam, a life and durability framework, ergonomics limits, a laboratory type test for illumination over the useful working period, and user-information and marking rules. Annex A gives practical examples of how users can carry out routine testing, including a photometric sphere method and a results table for lamp-room records.

Figure A.1 shows a typical photometric sphere arrangement for measuring luminous flux. Table A.1 gives a simple way to tabulate tests, faults and corrective action for caplights in service.

Relations

Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
09-Feb-2026
Effective Date
09-Feb-2026
Effective Date
06-May-2014

Buy Documents

Standard

SIST EN 60079-35-2:2012

English language (15 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

SIST EN 60079-35-2:2012 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Caplights for use in mines susceptible to firedamp - Part 2: Performance and other safety-related matters (IEC 60079-35-2:2011)". This standard covers: IEC 60079-35-2:2011 details those performance and other safety features of caplights, including those with a point of connection for another equipment, not covered in IEC 60079-35-1, but which are important for the safety and working conditions of the user. It may also be applied to caplights for use in mines not likely to be endangered by firedamp. This first edition of IEC 60079-35-2 cancels and replaces the second edition (2005) of IEC 62013-2 published in 2005 and constitutes a full technical revision. The general revision and updating of Edition 2 of IEC 62013-2 has been necessitated by the advent of new technologies related to caplight design, in particular those related light-emitting diode (LED) light sources. It is intended that there should be a stronger link between Part 1 (Construction) and Part 2 (Performance) of this Standard by upgrading the reference in the Scope of part 1 from a note to a requirement. In addition as this Standard is now to become one of the IEC 60079 series, changes have been made to bring it more in line with others in the series by cross referencing. This has enabled there to be a reduction in the number and length of clauses in the Standard.

IEC 60079-35-2:2011 details those performance and other safety features of caplights, including those with a point of connection for another equipment, not covered in IEC 60079-35-1, but which are important for the safety and working conditions of the user. It may also be applied to caplights for use in mines not likely to be endangered by firedamp. This first edition of IEC 60079-35-2 cancels and replaces the second edition (2005) of IEC 62013-2 published in 2005 and constitutes a full technical revision. The general revision and updating of Edition 2 of IEC 62013-2 has been necessitated by the advent of new technologies related to caplight design, in particular those related light-emitting diode (LED) light sources. It is intended that there should be a stronger link between Part 1 (Construction) and Part 2 (Performance) of this Standard by upgrading the reference in the Scope of part 1 from a note to a requirement. In addition as this Standard is now to become one of the IEC 60079 series, changes have been made to bring it more in line with others in the series by cross referencing. This has enabled there to be a reduction in the number and length of clauses in the Standard.

SIST EN 60079-35-2:2012 is classified under the following ICS (International Classification for Standards) categories: 29.260.20 - Electrical apparatus for explosive atmospheres; 73.100.20 - Ventilation, air-conditioning and illumination equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 60079-35-2:2012 has the following relationships with other standards: It is inter standard links to SIST EN ISO 80000-1:2023, SIST EN ISO 10692-1:2002, SIST EN 60079-35-1:2011, SIST EN 60983:2001, SIST EN 12405-2:2013, SIST EN 16314:2013, SIST EN 62013-2:2006. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 60079-35-2:2012 is associated with the following European legislation: EU Directives/Regulations: 94/9/EC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN 60079-35-2:2012 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 useful working period
  • 4 Light output
  • 4.1 Light sources
  • 4.2 Light source holder
  • 4.3 Luminous intensity and illuminance
  • 4.4 Auxiliary light source
  • 4.5 Focus
  • 4.6 Chromaticity
  • 5 Reliability
  • 5.1 Lamp life
  • 5.2 Battery life (charge/discharge cycles)
  • 5.3 Caplight useful working period
  • 5.4 Durability
  • 6 Ergonomics
  • 6.1 Mass
  • 6.2 Ease of operation
  • 6.3 Maintainability
  • 6.4 Headpiece security
  • 7 Type tests – Illumination throughout the useful working period
  • 8 Instructions
  • 9 Marking
  • Annex A
  • 1 Headpiece aperture
  • 2 Photocell
  • 3 Baffle

1 Scope

This part of IEC 60079-35 details those performance and other safety features of caplights, including those with a point of connection for another equipment, not covered in IEC 60079-35-1, but which are important for the safety and working conditions of the user. It may also be applied to caplights for use in mines not likely to be endangered by firedamp. NOTE When this part of the standard is used as a "stand-alone" document for non-gassy mines, any relevant constructional requirements should be the subject of agreement between the supplier and the user and, where possible, be as described in IEC 60079-35-1.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60050-845, International Electrotechnical Vocabulary (IEV) – Chapter 845: Lighting IEC 60983, Miniature lamps IEC 60079-35-1, Explosive atmospheres – Part 35-1: Caplights for use in mines susceptible to firedamp – General requirements – Construction and testing in relation to the risk of

explosion ISO 80000-1, Quantities and units – Part 1: General

3 Terms and definitions

For the purposes of this document, the definitions of ISO 80000-1 and IEC 60050(845) and the following apply:

3.1 useful working period

period in hours defined by the manufacturer, taking into account the current drawn by the main light source and if appropriate, the average current drawn by any accessories during that period, during which the main light source of the caplight may be continuously used and comply with the minimum luminous intensity requirements of this standard

4 Light output

4.1 Light sources

4.1.1 Every headpiece shall have a minimum of two light sources, at least one of which shall

be the main source and meet the requirements of this part of IEC 60079-35. Alternatively a

To be published

SIST EN 60079-35-2:2012

single light source may be used provided it is a non-filament type and it meets the lamp life defined in 5.1.

4.1.2 Where a caplight is fitted with two light sources, each of which is capable of being the

main source, the manufacturer shall designate which of these shall be the main source and which the auxiliary source; otherwise, both sources shall meet the requirements for the main source.

4.1.3 Filament lamps for main and auxiliary sources shall comply with IEC 60983. Where the

relevant data sheet is not given in IEC 60983, an equivalent shall be provided by the caplight manufacturer.

4.2 Light source holder

The holder for the main light source shall be capable of locating and retaining it securely in a focused position with respect to the reflector profile in accordance with 4.5.

4.3 Luminous intensity and illuminance

The main beam of light from a headpiece mounted on its intended helmet, in its normal operating orientation, shall point 10 degrees ± 5 degrees down from the horizontal. NOTE A statement from the caplight manufacturer stating compliance with this requirement is acceptable and need not be verified if certification is sought.

At the end of the useful working period, the luminous intensity from the main light source in a fully assembled headpiece, mounted on its intended helmet in its normal operating orientation, shall extend a cone with a minimum of 1 cd (1 lux at 1m). This cone shall not be less than 30 degrees up from the main beam of light, 60 degrees down from the main beam of light and 60 degrees to each side. This may be calculated from manufacturers’ data or tested in accordance with Clause 7. The maximum illumination shall not be less than 1 500 cd (1 500 lux at 1 m).

4.4 Auxiliary light source

The auxiliary light source is primarily intended for emergency use if the main source fails and is exempt from the type tests in Clause 7.

4.5 Focus

The main light source shall be focused, or capable of being focused, so that the light pattern is not impaired by distortion.

4.6 Chromaticity

For non-filament light sources, the colour correlated temperature (CCT) shall be greater than 5 000 K and the colour rendering index (CRI) shall be greater than 70, unless alternative values are specified by the caplight manufacturer and included in the user instructions. NOTE The values of CCT and CRI supplied by the caplight manufacturer need not be verified if certification is sought.

5 Reliability

5.1 Lamp life

The light source life of caplights fitted with two filament light sources shall comply with the requirements of Lamps for miners’ caplights in IEC 60983. If the lamp manufacturer provides a data sheet showing such test results, it may be accepted without further testing. The

SIST EN 60079-35-2:2012

minimum life shall be not less than 200 h for the main source and 50 h for the auxiliary source.

...