SIST EN 16314:2013
(Main)Gas meters - Additional functionalities
Gas meters - Additional functionalities
This European Standard specifies the additional requirements and tests for gas meters with a maximum capacity of 40 m3/h and a maximum operating pressure of not exceeding 500 mbar, conforming to EN 1359, EN 12261, EN 12480, EN 12405 and EN 14236, which have battery powered devices providing additional functionalities that form part of the gas meter (hereafter referred to as meter) or contained in an Additional Functionality Device (AFD). It also covers the additional requirements when an electronic index is used rather that a mechanical one. Where the option of an integral valve to the meter is specified, this standard only gives requirements for meters having a maximum capacity not exceeding 10 m3/h. This European Standard is applicable to first, second and third family gases according to EN 437. This European Standard specifies the construction requirements for electronic components but communication protocols are dealt within other European Standards, e.g. appropriate parts of EN 13757. This European Standard applies to AFDs that are installed in locations with vibration and shocks of low significance and in: - closed locations (indoor or outdoor with protection as specified by the manufacturer) with condensing or with non-condensing humidity, or, if specified by the manufacturer: - open locations (outdoor without any covering) with condensing humidity or with non-condensing humidity, - locations liable to temporary saturation, and in locations with electromagnetic disturbances corresponding to those likely to be found in residential, commercial buildings or similar buildings. This European Standard does not cover the changing of metrological software within the meter or the upload/download of metrological software. This European Standard only covers valves integral to the meter.
Gaszähler - Zusatzfunktionen
Diese Norm beschreibt die Zusatzanforderungen und -prüfungen für Gaszähler in Übereinstimmung mit EN 1359, EN 12261, EN 12480, EN 14236, die mit Zusatzfunktionen ausgerüstet sind, die entweder Teil des Zählers bilden oder in einem Zusatzfunktionsgerät enthalten sind. Sie behandelt auch die Zusatzanforderungen in Fällen, in denen das mechanische Zählwerk des Grundzählers durch ein elektronisches Zählwerk ersetzt wird. Wo die Alternative eines festeingebauten Ventils beschrieben ist, liefert diese Norm lediglich Anforderungen für Gaszähler, die eine maximale Leistung von 10 m3/h aufweisen.
Dieses Dokument gilt für Gase der 1., 2. und 3. Gasfamilie nach EN 437.
Dieses Dokument legt die Bauanforderungen für elektronische Bauelemente fest; Kommunikationsprotokolle werden hingegen in anderen europäischen Normen behandelt, z.B. EN 13757.
ANMERKUNG Dieses Dokument behandelt Anschlüsse an Zusatzgeräte, aber nicht die Anforderungen an diese Geräte.
Diese Norm gilt für ZFGs, die an Einsatzorten aufgestellt sind, an denen sie geringfügigen Erschütterungen und Stößen ausgesetzt sind, und für solche an:
- geschlossenen Aufstellungsorten (in Innenräumen oder im Freien, mit vom Hersteller vorgeschriebenem Schutz) mit kondensierender oder nicht kondensierender Feuchtigkeit;
oder, falls vom Hersteller angegeben:
- an offenen Aufstellungsorten (im Freien ohne Abdeckung) mit kondensierender Feuchtigkeit oder mit nicht-kondensierender Feuchtigkeit;
- an Aufstellungsorten, die einer zeitweiligen Sättigung unterliegen
und an Aufstellungsorten mit elektromagnetischen Störungen.
ANMERKUNG Diese Norm behandelt nicht das Auswechseln der messtechnischen Software oder das Hochladen/Herunterladen von messtechnischer Software.
Compteurs à gaz - Fonctionnalités supplémentaires
La présente Norme européenne précise les conditions et les essais supplémentaires pour les compteurs à gaz avec un débit maximal de 40 m3/h et une pression de service n’excédant pas 500 mbar, conformes aux EN 1359, EN 12261, EN 12480, EN 12405 et EN 14236, qui ont des dispositifs fonctionnant sur batterie et fournissant des fonctionnalités supplémentaires faisant partie intégrante du compteur de gaz (ci-après dénommé compteur) ou incluses dans un « Additional Fonctionality Device » (dispositif de fonctionnalité supplémentaire) (AFD). Elle couvre aussi les besoins supplémentaires quand l’index mécanique du compteur de base est remplacé par un index électronique. Lorsque l’option d’une vanne intégrée au compteur est spécifiée, cette norme donne les exigences seulement pour les compteurs de capacité n’excédant pas 10 m3/h.
La présente Norme européenne est applicable aux première, deuxième et troisième familles de gaz selon l’EN 437.
La présente Norme européenne précise les exigences de fabrication pour les composants électroniques mais les protocoles de communication sont traités par d’autres Normes européennes, par exemple les parties appropriées de l’EN 1 3757.
NOTE La présente Norme européenne couvre les raccordements aux dispositifs annexes mais pas les prescriptions de ces dispositifs.
La présente Norme européenne s’applique aux AFD installés dans des sites avec des vibrations et des chocs de faible importance et dans des :
- sites fermés (intérieurs ou extérieurs avec une protection comme spécifié par le fabricant) avec une humidité condensante ou non condensante;
ou, si spécifié par le fabricant :
- des sites ouverts (extérieurs sans couverture) avec humidité condensante ou non condensante ;
- des sites présentant un risque de saturation temporaire,
et dans des sites soumis à des perturbations électromagnétiques susceptibles d’être rencontrées dans les bâtiments résidentiels, commerciaux ou similaires.
La présente Norme européenne ne couvre pas le changement de logiciel de métrologie dans le compteur ni le téléchargement d’un logiciel de métrologie.
La présente Norme européenne ne couvre que les vannes faisant partie intégrante du compteur.
Plinomeri - Dodatne funkcije
Ta evropski standard določa dodatne zahteve in preskuse za plinomere z največjo kapaciteto 40 m3/h, pri katerih največji obratovalni tlak ne preseže 500 mbar, v skladu s standardi EN 1359, EN 12261, EN 12480, EN 12405 in EN 14236, ki vsebujejo naprave, ki se napajajo prek baterij in zagotavljajo dodatne funkcije, ki so del plinomera (v nadaljevanju: merilniki), ali so zajete med napravami z dodatnimi funkcijami (AFD). Zajema tudi dodatne zahteve v primerih, ko je uporabljen elektronski indeks namesto mehanskega indeksa. Če je določena možnost z vgrajenim ventilom v merilniku, ta standard podaja le zahtevo, da največja kapaciteta merilnikov ne sme preseči 10 m3/h. Ta evropski standard se uporablja za pline prve, druge in tretje družine v skladu s standardom EN 437. Ta evropski standard določa konstrukcijske zahteve za elektronske komponente, komunikacijski protokoli pa so urejeni z drugimi evropskimi standardi, npr. z ustreznimi deli standarda EN 13757. Ta evropski standard se uporablja za naprave z dodatnimi funkcijami, ki so nameščene na mestih, kjer so prisotni tresljaji in udarci majhnega pomena in na: – zaprtih lokacijah (znotraj ali na prostem z zaščito, kot jo določa proizvajalec) s kondenzirano ali nekondenzirano vlago, ali, če je tako določil proizvajalec: – odprtih lokacijah (na prostem brez kakršnega koli prekrivala) s kondenzirano ali nekondenzirano vlago, – lokacijah, kjer lahko pride do začasnega nasičenja in lokacijah z elektromagnetnimi motnjami, ki ustrezajo običajnim motnjam v stanovanjskih, komercialnih ali podobnih zgradbah. Ta evropski standard ne zajema sprememb meroslovne programske opreme merilnika ali prenosa/nalaganja programske opreme merilnika. Ta evropski standard zajema samo ventile, vgrajene v merilniku.
General Information
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Plinomeri - Dodatne funkcijeGaszähler - ZusatzfunktionenCompteurs à gaz - Fonctionnalités supplémentairesGas meters - Additional functionalities91.140.40Sistemi za oskrbo s plinomGas supply systemsICS:Ta slovenski standard je istoveten z:EN 16314:2013SIST EN 16314:2013en,fr,de01-december-2013SIST EN 16314:2013SLOVENSKI
STANDARD
SIST EN 16314:2013
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 16314
July 2013 ICS 91.140.40 English Version
Gas meters - Additional functionalities
Compteurs à gaz - Fonctionnalités supplémentaires
Gaszähler - Zusatzfunktionen This European Standard was approved by CEN on 18 April 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16314:2013: ESIST EN 16314:2013
EN 16314:2013 (E) 2 Contents Page Foreword . 4 Introduction . 5 1 Scope . 6 2 Normative references . 6 3 Terms, definitions and abbreviated terms . 8 3.1 Terms and definitions . 8 3.2 Abbreviated terms . 9 4 General requirements . 10 4.1 Meter . 10 4.2 Meters with electronic index . 10 4.3 Suitability – AFD/Meter combination . 10 4.4 Types of additional functionality devices . 10 4.5 AFD1 . 11 4.6 AFD2 . 11 4.7 AFD3 . 11 4.8 Resistance to high ambient temperature . 12 4.9 Climatic environments . 12 4.10 Gas temperature range . 16 4.11 Safety Requirements . 16 4.12 Immunity to electromagnetic disturbances . 16 4.13 Immunity to electromagnetic disturbances for Meters / AFD’s with external ports . 20 4.14 Resistance to mishandling . 23 4.15 Resistance to storage temperature . 23 4.16 Ageing test . 24 4.17 Expected lifetime . 24 5 Security. 24 5.1 General . 24 5.2 Software, data and hardware security . 25 5.3 Firmware upgrade . 25 5.4 Software identification . 26 6 Power system . 26 6.1 General . 26 6.2 Battery . 26 6.3 Battery life . 27 6.4 Battery compartment . 27 6.5 Battery replacement . 28 6.6 Battery lifetime totaliser . 29 6.7 Voltage interruptions . 29 6.8 Operating voltage . 29 7 Additional Functionalities . 30 7.1 General . 30 7.2 Display . 30 7.3 Diagnostics. 30 7.4 Metrological influence . 31 7.5 AFD connections . 31 7.6 Input to AFD . 31 7.7 Output from AFD . 31 7.8 Data storage . 32 SIST EN 16314:2013
EN 16314:2013 (E) 3 7.9 Time interval accuracy . 33 7.10 Energy Calculation within the meter/AFD . 34 7.11 Tariffs . 34 7.12 Display/Human interface . 35 7.13 Gas valve and System . 35 7.14 Registers . 41 7.15 Prepayment System with valve . 41 7.16 Prepayment system without a valve . 42 7.17 History of Consumption . 42 7.18 Memory . 42 8 Marking . 44 8.1 Requirements . 44 8.2 Test . 44 9 Documentation . 44 9.1 General . 44 9.2 Declaration of conformity . 45 9.3 Technical documentation. 45 9.4 Instruction manual . 45 10 Environmental considerations . 45 Annex A (informative)
Download software . 46 Annex B (informative)
Implementation method – Conformity to the SM-CG Additional Functionalities . 47 Annex C (normative)
Electronic index. 50 C.1 General . 50 C.2 Display . 50 C.3 Display reset . 50 C.4 Test signal . 51 C.5 Non-volatile memory . 51 C.6 Flags and alarms information . 52 C.7 Interfaces . 52 C.8 Ports. 52 C.9 Durability . 53 Annex D (normative)
Valve type test plan . 54 D.1 List of tests . 54 D.2 Endurance Test . 54 D.3 Toluene/iso-octane test . 54 D.4 Water Vapour Test . 57 D.5 Ageing Test. 59 Bibliography . 60
SIST EN 16314:2013
EN 16314:2013 (E) 4 Foreword This document (EN 16314:2013) has been prepared by Technical Committee CEN/TC 237 “Gas meters”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2014, and conflicting national standards shall be withdrawn at the latest by January 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 16314:2013
EN 16314:2013 (E) 5 Introduction
This European Standard has been drafted as part of the work being undertaken by the European Standards Organisations (CEN/CENELEC/ETSI) under the Commission Mandate M/441. This standard utilises the six functionalities agreed by the Smart Meters Coordination Group (SM-CG) (see Annex C) as the basis for its additional functionalities. It is not necessary for the Additional Functionality Device (AFD) to incorporate all functions. This standard builds on CEN/TR 16061 by providing specific requirements for the additional functionality that can be fitted to a gas meter.
This standard contains requirements for gas valves integral within the meters and controlled by an AFD where the capacity of the gas meter does not exceed 10 m3/h. Such gas valves are intended for interruption of the gas supply but do not replace any valve intended to isolate the gas supply. Communications for gas meters are outside the scope of this standard and are covered by the appropriate parts of EN 13757, which provide a number of protocols and transport layers for meter communications for Gas, Water and Heat meters. A number of methods can provide the additional functionality for gas meters: these are illustrated below, see Figure 1, and described in detail within this standard. The AFD can be integral to the gas meter, attached to the meter or remote from the meter. AFD1, AFD2 and AFD3Gas Meter+ AFD1 AdditionalFunctionsOther devices, e.g, Home displayGas MeterAFD2 AdditionalFunctionsOther devices, e.g, Home displayGas MeterAFD3 AdditionalFunctionsOther devices, e.g, Home displayIn scope Out of scope Figure 1 — Additional functionality device
SIST EN 16314:2013
EN 16314:2013 (E) 6 1 Scope This European Standard specifies the additional requirements and tests for gas meters with a maximum capacity of 40 m3/h and a maximum operating pressure of not exceeding 500 mbar, conforming to EN 1359, EN 12261, EN 12480, EN 12405 and EN 14236, which have battery powered devices providing additional functionalities that form part of the gas meter (hereafter referred to as meter) or contained in an Additional Functionality Device (AFD). It also covers the additional requirements when an electronic index is used rather that a mechanical one. Where the option of an integral valve to the meter is specified, this standard only gives requirements for meters having a maximum capacity not exceeding 10 m3/h.
This European Standard is applicable to first, second and third family gases according to EN 437.
This European Standard specifies the construction requirements for electronic components but communication protocols are dealt within other European Standards, e.g. appropriate parts of EN 13757. NOTE This European Standard covers connections to auxiliary devices but not the requirements for these devices. This European Standard applies to AFDs that are installed in locations with vibration and shocks of low significance and in: closed locations (indoor or outdoor with protection as specified by the manufacturer) with condensing or with non-condensing humidity, or, if specified by the manufacturer: — open locations (outdoor without any covering) with condensing humidity or with non-condensing humidity, — locations liable to temporary saturation,
and in locations with electromagnetic disturbances corresponding to those likely to be found in residential, commercial buildings or similar buildings. This European Standard does not cover the changing of metrological software within the meter or the upload/download of metrological software. This European Standard only covers valves integral to the meter. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1359, Gas meters — Diaphragm gas meters EN 12261, Gas meters — Turbine gas meters EN 12405-2, Gas meters — Conversion devices — Part 2: Energy conversion EN 12480, Gas meters — Rotary displacement gas meters EN 13611, Safety and control devices for gas burners and gas-burning appliances — General appliances EN 13757-1, Communication system for meters and remote reading of meters — Part 1: Data exchange EN 13757-2, Communication systems for remote reading of meters — Part 2: Physical and link layer SIST EN 16314:2013
EN 16314:2013 (E) 7 EN 13757-3, Communications systems for and remote reading of meters — Part 3: Dedicated application layer EN 13757-4, Communication systems for meters and remote reading of meters — Part 4: Wireless meter readout (radio meter reading for operation in the 868 MHz to 870 MHz SRD band) EN 13757-5, Communications systems for and remote reading of meters — Part 5: Wireless relaying EN 13757-6, Communications systems for and remote reading of meters — Part 6: Local bus EN 14236, Ultrasonic domestic gas meters EN 55022, Information Technology Equipment — Radio disturbance characteristics — Limits and methods of measurement
EN 60079 (all parts), Explosive atmospheres
EN 60086-1, Primary batteries — Part 1: General
EN 60086-4, Primary batteries — Part 4: Safety of lithium batteries
EN 60529, Degrees of protection provided by enclosures (IP code) EN 60950-1, Information technology equipment — Safety — Part 1: General requirements EN 61000-4-2, Electromagnetic compatibility (EMC) — Part 4-2: Testing and measurement techniques — Electrostatic discharge immunity test EN 61000-4-3, Electromagnetic compatibility (EMC) — Part 4-3: Testing and measurement techniques — Radiated, radio-frequency, electromagnetic field immunity test EN 61000-4-4, Electromagnetic compatibility (EMC) — Part 4-4: Testing and measurement techniques — Electrical fast transient/burst immunity test EN 61000-4-5, Electromagnetic compatibility (EMC) — Part 4-5: Testing and measurement techniques — Surge immunity test EN 61000-4-6, Electromagnetic compatibility (EMC) — Part 4-6: Testing and measurement techniques — Immunity to conducted disturbances, induced by radio-frequency fields EN 61000-4-8, Electromagnetic compatibility (EMC) — Part 4-8: Testing and measurement techniques — Power frequency magnetic field immunity test EN 61000-4-9, Electromagnetic compatibility (EMC) — Part 4-9: Testing and measurement techniques — Pulse magnetic field immunity test EN 61000-6-1, Electromagnetic compatibility (EMC) — Part 6-1: Generic standards — Immunity for residential, commercial and light-industrial environments EN 61000-6-2, Electromagnetic compatibility (EMC) — Part 6-2: Generic standards — Immunity for industrial environments EN 61010-1, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 1: General requirements EN 62056-21, Electricity metering — Data exchange for meter reading, tariff and load control — Part 21: Direct local data exchange SIST EN 16314:2013
EN 16314:2013 (E) 8 EN ISO 4892-3, Plastics — Methods of exposure to laboratory light sources — Part 3: Fluorescent UV lamps (ISO 4892-3) EN ISO 6270-1, Paints and Varnishes — Determination of resistance to humidity — Part 1: Continuous condensation (ISO 6270-1) EN ISO 13849-1, Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design (ISO 13849-1) IEC 61508-1, Functional safety of electrical/electronic/programmable electronic safety-related systems — Part 1: General Requirements ISO 7724-3, Paints and Varnishes — Colorimetry — Part 3: Calculation of colour differences ASTM D1003, Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics (edition 11) 3 Terms, definitions and abbreviated terms 3.1 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1.1 function process which constantly or at defined intervals, automatically or on demand, performs specific activities such as sampling data, reading a data set, verifying or changing a status, or activating a switch 3.1.2 additional functionality functions over and above that within the meter, which can be integral to the meter, or included within a connected device 3.1.3 additional functionality device carries out the additional functionalities 3.1.4 additional functionality device Type 1 factory fitted additional functionality integral within the meter
3.1.5 additional functionality device Type 2 factory or field fitted additional functionality directly attached to the meter 3.1.6 additional functionality device Type 3 field fitted additional functionality connected to the meter 3.1.7 meter instrument designed to measure, memorise and display the quantity of gas (volume or mass) that has passed it Note 1 to entry: A volume conversion device is a sub-assembly of a meter and therefore in this standard it is part of the meter. SIST EN 16314:2013
EN 16314:2013 (E) 9 3.1.8 automatic meter reading technology for obtaining metering data from an on-site meter by communication from an access point outside the premises
3.1.9 connector mechanical device, or pair of devices, that makes a semi-permanent circuit between the meter and a cable 3.1.10 universal time coordinated world time, without daylight savings 3.1.11 index current reading of the total volume (mass) passed through the meter 3.1.12 metrological software software identified during the type testing examination, which is part of the meter and is critical to its metrological characteristics 3.1.13 register electronic component which memorises the values of the meter and/or the AFD 3.1.14 maximum permissible error extreme value of measurement error, with respect to a known reference quantity value, permitted by specifications or regulations for a given measurement, measuring instrument, or measuring system 3.1.15 tariff price structure (normally comprising a set of one or more rates of charge) applied to the consumption of a product or service provided to a consumer
3.1.16 event condition requiring action or to log an action 3.1.17 display shows visual information in either numbers or text 3.2 Abbreviated terms Table 1 — Abbreviations AFD1 Additional functionality device Type 1 AFD2 Additional functionality device Type 2 AFD3 Additional functionality device Type 3 UTC Universal Time Coordinated MPE Maximum Permissible Error
SIST EN 16314:2013
EN 16314:2013 (E) 10 4 General requirements 4.1 Meter A meter shall comply with one of the following European Standards: EN 1359, EN 12405-2, EN 12261, EN 12480 or EN 14236 as applicable. 4.2 Meters with electronic index Where a meter conforming to 4.1 is equipped with a primary electronic index, the electronic index and its associated software and hardware shall meet the requirements of Annex C and the relevant parts of this standard and the meter standard. 4.3 Suitability – AFD/Meter combination The AFD shall work at the same minimum operating conditions as the meter required by the appropriate above mentioned standards. The AFD shall be connected to the meter and tested as a combined unit in all the tests given in 4.4 to 4.17 to ensure the connection of the AFD to the meter has no metrological influence. The connection of the AFD to the meter or any labelling on the meter/AFD shall not obscure or damage the metrological seals of the meter. The index on the meter shall not be obscured by the connection of the AFD and the index shall be accessible to the consumer without the use of tools.
The manufacturer of the AFD shall declare the conditions for compatibility with any interface and meters. 4.4 Types of additional functionality devices The additional functionality shall be provided by one of the following devices: a) AFD1, b) AFD2, c) AFD3. In the case of an AFD1, all functions shall be within the same casing as the meter. In the case of an AFD2, the AFD2 shall be directly attached to the meter.
In the case of an AFD3, the AFD3 shall be connected to the meter.
The fitting of the AFD to the meter shall not obstruct or obscure the metrological seal. The AFD shall be connected to the meter in accordance with the manufacturer's instructions during all tests specified in this standard. The index shall be easily read without the use of tools by the consumer and shall be unambiguously and boldly displayed within the index. SIST EN 16314:2013
EN 16314:2013 (E) 11 4.5 AFD1 4.5.1 Requirements When tested in accordance with 4.5.2, the AFD shall have no influence on the metrological characteristics of the meter. 4.5.2 Test Test the meter with the AFD1 incorporated according to the appropriate standard, i.e. EN 1359, EN 12405-2, EN 12480, EN 12261 or EN 14236, to ensure conformity. 4.6 AFD2 4.6.1 Requirements a) When tested in accordance with 4.6.2 a), the AFD shall have no influence on the metrological characteristics of the meter. b) If the AFD provides a facsimile of the meter’s results, it shall be tested in accordance with 4.6.2 b) to ensure these results are identical to that on the meter. c) When tested in accordance with 4.6.2 c), the AFD shall operate with the interfaces specified by the manufacturer and display the information as specified by the manufacturer.
d) There shall be the possibility to be able to apply a protective seal between the ADF and the meter. 4.6.2 Test a) Fit the AFD to the meter and undertake the relevant tests specified in Clauses 4 and 7. b) Examine the meter and AFD and ensure these results are identical to that on the meter. c) Verify the AFD is interoperable with those interfaces specified by the manufacturer. d) Examine the meter and AFD and ensure t
...