Status
Not Published
Current Stage
6000 - International Standard under publication - 60 Publication
Start Date
22-Oct-2026

Buy Documents

Draft

ISO/FDIS 25408-2 - Testing method for bead wire — Part 2: Adhesion test

Release Date:12-Aug-2026
English language (10 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/FDIS 25408-2 - Testing method for bead wire — Part 2: Adhesion test

Release Date:12-Aug-2026
English language (10 pages)
sale 15% off
sale 15% off

ISO 25408-2, published by ISO, specifies a laboratory test method for the adhesion strength of bead wire to vulcanized rubber compounds. It is written for round and shaped bead wire, including wire made from brass, bronze, or zinc coated steel wire, and it explains how to prepare specimens, carry out the pull-out test, and report the results.

What does ISO 25408-2 specify?

ISO 25408-2 specifies the test method, the test equipment, the specimen preparation steps, and the way to report adhesion results for bead wire. The document is organized into clauses 1 to 10, covering scope, normative references, terms and definitions, principle, apparatus, procedure, calculation and report of pull-out force, precision and variance, rubber coverage rate (RCR), and calculation and report of RCR.

The method is aimed at comparing how strongly bead wire bonds to cured rubber in a controlled vulcanized block. In practice, that matters when a lab needs repeatable adhesion data for material qualification, process control, or incoming inspection.

What are the key requirements of ISO 25408-2?

Specimen preparation and vulcanization

ISO 25408-2 requires bead wire specimens to be vulcanized into a rubber block before testing. Clause 6 describes two preparation routes - a hot moulding method and a pre-building mould method - and both depend on careful handling to avoid contaminating the wire or rubber surfaces.

The document also requires a defined specimen layout: four bead wire samples, each cut into at least three test specimens. That means the result is based on repeated measurements, not a single pull, which improves comparability between lots and laboratories.

Test equipment and test conditions

ISO 25408-2 requires a constant-rate-of-extension (CRE) tensile testing machine with force and extension recording, and a block holder with a circular hole so the load is applied with homogeneous stress. It also specifies a vulcanization press, mould, rubber cutter, and cleaning tools suitable for the block and wire dimensions.

These requirements matter because adhesion results are sensitive to pressure, temperature, alignment, and test speed. The press must control vulcanization conditions, and the pull-out setup must keep the specimen centered and perpendicular so the measured force reflects adhesion rather than bending or grip slip.

Pull-out test and reporting

ISO 25408-2 measures the force needed to pull the bead wire linearly out of the rubber block. Clause 6.6 sets the pull-out test sequence, and Clause 7 says the pull-out force is reported as the average of three specimens for each sample, rounded to the nearest 1 N.

Clause 7 also states that reference material results are for internal monitoring only. In practice, the main report is the average pull-out force for each bead wire sample, while the reference material helps confirm that the vulcanization process stayed stable.

Precision and rubber coverage rate

ISO 25408-2 includes a precision section that expresses variance as coefficient of variation (CV) and gives maximum acceptable CV values by bead wire diameter. That gives users a way to judge whether their round-robin or internal study is stable enough to support the results.

Clauses 9 and 10 add rubber coverage rate (RCR), which is a visual estimate of how much rubber remains on the pulled wire surface. The document uses 8x magnification and LED light for evaluation, and reports the average RCR to the nearest 1% and also by code ranges A to D. This gives a second view of adhesion, beyond force alone, because the wire surface appearance can show how the bond failed.

What terms does ISO 25408-2 define?

ISO 25408-2 uses the bead wire terminology from ISO 16650, which is the normative reference for terms and definitions. Key terms and abbreviations used in the document include:

  • Bead wire - the round or shaped wire being tested for adhesion to rubber.
  • Constant-rate-of-extension (CRE) - a tensile testing mode where the extension rate is controlled during the pull-out test.
  • Pull-out force (POF) - the maximum force recorded when the bead wire is pulled from the rubber block.
  • Rubber coverage rate (RCR) - the judged percentage of rubber remaining on the wire surface after pull-out.
  • Coefficient of variation (CV) - the standard deviation divided by the mean, expressed as a percentage, used to express precision.
  • Reference material (RM) - a material with stable, known adhesion performance used to monitor the process.
  • Vulcanization press - the heated press used to cure the rubber block around the bead wire.

Who uses ISO 25408-2?

ISO 25408-2 is used by bead wire manufacturers, tire and rubber compound laboratories, and quality control teams that need to compare adhesion performance. Test laboratories use it to run controlled pull-out tests and to monitor process stability with reference material.

It is also useful for buyers, suppliers, and technical auditors who need a common method for checking whether bead wire and vulcanized rubber behave consistently during production or qualification testing.

Which standards are used with ISO 25408-2?

ISO 16650 is the normative reference in ISO 25408-2. It provides the bead wire terms and definitions that apply when using this adhesion test method.

What does the ISO 25408-2 document contain?

ISO 25408-2 contains detailed apparatus descriptions for the tensile machine, vulcanization press, mould, block holder, solvent handling, and cutting tools. It also includes step-by-step procedures for rubber preparation, mould preparation, sample layout, curing, cleaning, and pull-out testing.

The document includes figures for the mould and block holder, plus tables for CV limits, RCR evaluation criteria, and RCR report codes. It also gives the calculation method for averaging pull-out force and rubber coverage rate across repeated specimens, which supports testing, process control, and reporting.

Buy Documents

Draft

ISO/FDIS 25408-2 - Testing method for bead wire — Part 2: Adhesion test

Release Date:12-Aug-2026
English language (10 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/FDIS 25408-2 - Testing method for bead wire — Part 2: Adhesion test

Release Date:12-Aug-2026
English language (10 pages)
sale 15% off
sale 15% off

Get Certified

Connect with accredited certification bodies for this standard

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Element Materials Technology

Materials testing and product certification.

UKAS United Kingdom Verified

Inštitut za kovinske materiale in tehnologije

Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

ISO 25408-2 is a draft published by the International Organization for Standardization (ISO). Its full title is "Testing method for bead wire — Part 2: Adhesion test". This standard covers: Testing method for bead wire — Part 2: Adhesion test

Testing method for bead wire — Part 2: Adhesion test

ISO 25408-2 is classified under the following ICS (International Classification for Standards) categories: 77.140.65 - Steel wire, wire ropes and link chains; 83.140.01 - Rubber and plastics products in general; 83.160.01 - Tyres in general. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 25408-2 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Principle
  • 5 Apparatus
  • 5.1 Tensile testing machine
  • 5.2 Vulcanization press
  • 5.3 Mould
  • 5.4 Block holder
  • 5.5 Rubber pad remover and pressure roll
  • 5.6 Solvent
  • 5.7 Rubber cutter
  • 5.8 Consumable
  • 6 Procedure
  • 6.1 Preparation for rubber compound
  • 6.2 Preparation for vulcanization mould
  • 6.3 Sample preparation
  • 6.4 Preparation of the rubber block
  • 6.5 Cleaning process
  • 6.6 Pull out test
  • 7 Calculation and report of pull-out force
  • 8 Precision and variance
  • 9 Rubber coverage rate (RCR)
  • 10 Calculation and report of rubber coverage rate (RCR)

1 Scope

This document specifies the test method for strength of adhesion of bead wire (round and shaped) to vulcanized rubber compounds.

The method applies to, but is not limited to, wire made from brass, bronze, or zinc coated steel wire.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 16650, Bead wire

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 16650 apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https:// www .iso .org/ obp
  • IEC Electropedia: available at https:// www .electropedia .org/

4 Principle

Specimens of bead wire are vulcanized into a block of rubber and force necessary to pull bead wires that are linearly out of the rubber is measured. The used clamp or block holder shall be equipped with a circle hole to guarantee the homogenous stress. If required, the visual evaluation of rubber coverage is also determined.

5 Apparatus

5.1 Tensile testing machine

a) The constant-rate-of-extension (CRE) tensile testing machine capacity that the measured force is required to fracture the wire shall be within force measurement range. The device shall be equipped with a load and extension recorder, digital read-out, automated data logger or computer controlled tensile test machine.

b) Cross-head speed: maximum speed shall be ≥ 150 mm/min. (≠ test speed). c) Machine accuracy Class 0,5 = Load weighing accuracy: ± 0,5 %. d) Load cell capacity depends on the type and characteristics of the wire.

ISO/FDIS 25408-2:2026(en)

5.2 Vulcanization press

a) The machine type of vulcanization press can be electrical or steam heat which is large enough to take the mould dimensions and capable of a minimum pressure of 3,5 MPa over the total area of the mould plate used.

b) Dimension of the press platens: minimum 400 mm × 400 mm.

c) Temperature capacity: maximum 200 °C.

d) For a standard 1 cavity mould (50 mm embed) a pressure of 70 kN to 100 kN is to apply. e) Heating for the top and the bottom platens shall be of sufficient capacity for maintaining the mould components at the specific temperatures required for the rubber compound being used. f) The heat up power of the press shall be min 10 °C/min or better 20 °C/min. g) Temperature resolution: 0,5 °C.

h) Temperature in the rubber shall be controlled within ±2 °C during vulcanization.

5.3 Mould

a) Mould designed for a 13 mm thick block of rubber, 222 mm long, and 50 mm wide, with 15 wire slots across the width of the mould spaced 13 mm apart at the middle of the mould thickness, and with top and bottom plates for the mould.

b) Moulds with embed lengths of 12,5 mm ,15 mm , 20 mm or 25 mm may be used, as specified and agreed by relevant parties.

c) The 15 wire slots have a typical ‘Y’ shape groove for bead wire adhesion testing. d) The ‘Y’ shape slot width can be according to wire thickness. Standard slot widths are 1,15 mm and 2,1 mm and 3,1 mm. Standard depth of ‘Y’ shape slots is 7,5 mm (see Figure 1). Figure 1 — Vulcanization mould

ISO/FDIS 25408-2:2026(en)

5.4 Block holder

The block holder grip shall be a special holder made for the vulcanized block sample. The opposite grip may be any type of clamp of sufficient capacity to handle the specimen and designed to prevent its slippage in the grip area (see Figure 2).

NOTE 1 The dimensions all with accuracy ±0,2 mm except where noted. NOTE 2 Material is steel.

NOTE 3 Break all sharp corners.

Figure 2 — Block holder

5.5 Rubber pad remover and pressure roll

Rubber pad remover or manual mould ejector is recommended for safely and quickly removing of rubber block out of the hot mould without extreme bending of the ongoing adhesion pad.

5.6 Solvent

a) The use of solvent on rubber surface or bead wire surface can influence the adhesion process. b) Cleaning or even touching rubber surface and bead wire surface is not allowed. c) Only if the requester really requires cleaning the rubber surface or the bead wire surface is it allowed. d) The re-freshening action shall take place at least 10 minutes prior to the pad assembly.

ISO/FDIS 25408-2:2026(en) e) A suitable solvent has been found to be lead-free gasoline (normal heptane’s), with a distillation range from 40 °C to 141 °C and a maximum recovery of 97 %, available from most solvent suppliers.

5.7 Rubber cutter

a) The rubber cutter shall be able to cut rubber with a thickness of 7 mm with acceptable precision to achieve correct rubber sheath dimensions.

b) A big paper cutter or clicker dies with exact target dimensions are to be used.

5.8 Consumable

5.8.1 Rubber compound

a) The rubber compound can be provided in sheath form, 7 mm thick on a non-hygroscopic backing, such as a plasticizer free plastic material, or may be provided un-milled in a form requiring milling immediately prior to use.

b) The rubber compound shall be provided together with information on storage conditions and shelf - life. If no specific requirements are specified by agreement between relevant parties, the storage conditions and shelf - life shall comply with the following requirements:

1) The rubber compound shall be stored in the laboratory environment with a temperature of (23 ± 5) °C and a humidity of (40 to 55) % RH. It shall be protected from light. The shelf life is 3 months; 2) Or store the rubber compound in a refrigerator at (5 ± 5) °C. The shelf life is 6 months. If the rubber compound is stored in a freezer at (5 ± 5) °C, it shall be taken out of the freezer 24 hours in advance before use.

5.8.2 Mould release lubricant:

Mould release lubricant can be applied to an empty mould to limited residue rubber parts on the mould after vulcanization and to ease test block removal. Mould release spray cannot be applied just before mould build-up process. It is best to apply mould release spray before a time-out period of at least 2 h before next vulcanization and let the spray be evaporated during that time.

...

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Principle
  • 5 Apparatus
  • 5.1 Tensile testing machine
  • 5.2 Vulcanization press
  • 5.3 Mould
  • 5.4 Block holder
  • 5.5 Rubber pad remover and pressure roll
  • 5.6 Solvent
  • 5.7 Rubber cutter
  • 5.8 Consumable
  • 6 Procedure
  • 6.1 Preparation for rubber compound
  • 6.2 Preparation for vulcanization mould
  • 6.3 Sample preparation
  • 6.4 Preparation of the rubber block
  • 6.5 Cleaning process
  • 6.6 Pull out test
  • 7 Calculation and report of pull-out force
  • 8 Precision and variance
  • 9 Rubber coverage rate (RCR)
  • 10 Calculation and report of rubber coverage rate (RCR)

1 Scope

This document specifies the test method for strength of adhesion of bead wire (round and shaped) to vulcanized rubber compounds.

The method applies to, but is not limited to, wire made from brass, bronze, or zinc coated steel wire.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 16650, Bead wire

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 16650 apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • — ISO Online browsing platform: available at https://www.iso.org/obp
  • — IEC Electropedia: available at https://www.electropedia.org/

4 Principle

Specimens of bead wire are vulcanized into a block of rubber and force necessary to pull bead wires that are linearly out of the rubber is measured. The used clamp or block holder shall be equipped with a circle hole to guarantee the homogenous stress. If required, the visual evaluation of rubber coverage is also determined.

5 Apparatus

5.1 Tensile testing machine

a) a) The constant-rate-of-extension (CRE) tensile testing machine capacity that the measured force is required to fracture the wire shall be within force measurement range. The device shall be equipped with a load and extension recorder, digital read-out, automated data logger or computer controlled tensile test machine.

b) b) Cross-head speed: maximum speed shall be ≥ 150 mm/min. (≠ test speed)). c) c) Machine accuracy Class 0,5 = Load weighing accuracy: +/-± 0,5 %%. d) d) Load cell capacity depends on the type and characteristics of the wire.

ISO/FDIS 25408-2:2026(en)

5.2 Vulcanization press

a) a) The machine type of vulcanization press can be electrical or steam heat which is large enough to take the mould dimensions and capable of a minimum pressure of 3,5 MPa over the total area of the mould plate used.

b) b) Dimension of the press platens: minimum 400 mm x× 400 mm. c) c) Temperature capacity: maximum 200 °C.

d) d) For a standard 1 cavity mould (50 mm embed) a pressure of 70 kN to 100 kN is to apply. e) e) Heating for the top and the bottom platens shall be of sufficient capacity for maintaining the mould components at the specific temperatures required for the rubber compound being used. f) f) The heat up power of the press shall be min 10 °C/min or better 20 °C/min. g) g) Temperature resolution: 0,5 °C.

h) h) Temperature in the rubber shall be controlled within ±2 °C during vulcanization.

5.3 Mould

a) a) Mould designed for a 13 mm thick block of rubber, 222 mm long, and 50 mm wide, with 15 wire slots across the width of the mould spaced 13 mm apart at the middle of the mould thickness, and with top and bottom plates for the mould.

b) b) Moulds with embed lengths of 12,5 mm ,15 mm , 20 mm or 25 mm may be used, as specified and agreed by relevant parties.

c) c) The 15 wire slots have a typical ‘Y’ shape groove for bead wire adhesion testing. d) d) The ‘Y’ shape slot width can be according to wire thickness. Standard slot widths are 1,15 mm and 2,1 mm and 3,1 mm. Standard depth of ‘Y’ shape slots is 7,5 mm (see Figure 1Figure 1).).

ISO/FDIS 25408-2:2026(en)

Figure 1 — Vulcanization mould

5.4 Block holder

The block holder grip shall be a special holder made for the vulcanized block sample. The opposite grip may be any type of clamp of sufficient capacity to handle the specimen and designed to prevent its slippage in the grip area (see Figure 2Figure 2).).

ISO/FDIS 25408-2:2026(en)

Key

ISO/FDIS 25408-2:2026(en)

NOTE 1 The dimensions all with accuracy ±0.,2 mm except where noted. NOTE 2 Material is steel.

NOTE 3 Break all sharp corners.

Figure 2 — Block holder

5.5 Rubber pad remover and pressure roll

Rubber pad remover or manual mould ejector is recommended for safely and quickly removing of rubber block out of the hot mould without extreme bending of the ongoing adhesion pad.

5.6 Solvent

a) a) The use of solvent on rubber surface or bead wire surface can influence the adhesion process. b) b) Cleaning or even touching rubber surface and bead wire surface is not allowed. c) c) Only if the requester really requires cleaning the rubber surface or the bead wire surface is it allowed.

d) d) The re-freshening action shall take place at least 10 minutes prior to the pad assembly.

ISO/FDIS 25408-2:2026(en) e) e) A suitable solvent has been found to be lead-free gasoline (normal heptane’s), with a distillation range from 40 °C to 141 °C and a maximum recovery of 97 %, available from most solvent suppliers.

5.7 Rubber cutter

a) a) The rubber cutter shall be able to cut rubber with a thickness of 7 mm with acceptable precision to achieve correct rubber sheath dimensions.

b) b) A big paper cutter or clicker dies with exact target dimensions are to be used.

5.8 Consumable

5.8.1 Rubber compound

a) a) The rubber compound can be provided in sheath form, 7 mm thick on a non-hygroscopic backing, such as a plasticizer free plastic material, or may be provided un-milled in a form requiring milling immediately prior to use.

b) b) The rubber compound shall be provided together with information on storage conditions and shelf - life. If no specific requirements are specified by agreement between relevant parties, the storage conditions and shelf - life shall comply with the following requirements:

1) 1) The rubber compound shall be stored in the laboratory environment with a temperature of (23 ± 5) °C and a humidity of (40- to 55) % RH. It shall be protected from light. The shelf life is 3 months; 2) 2) Or store the rubber compound in a refrigerator at (5 ± 5) °C. The shelf life is 6 months. If the rubber compound is stored in a freezer at (5 ± 5) °C, it shall be taken out of the freezer 24 hours in advance before use.

5.8.2 Mould release lubricant:

Mould release lubricant can be applied to an empty mould to limited residue rubber parts on the mould after vulcanization and to ease test block removal. Mould release spray cannot be applied just before mould buildup process. BestIt is best to apply mould release spray before a time-out period of at least 2 hoursh before next vulcanization and let the spray be evaporated during that time.

...