IEC 61169-19:2011
(Main)Radio-frequency connectors - Part 19: Sectional specification - Radio frequency coaxial connectors of type SSMB
General Information
- Abstract
IEC 61169-19:2011 is a sectional specification. It provides information and rules for preparation of detail specification of SSMB series R.F connectors together with the pro forma blank detail specification The SSMB series connectors with characteristic impedance 50 ohm are one kind of low power miniature connectors with snap-on coupling mechanism and have the characteristics of light weight, small size, convenient connection and excellent characteristics. This connector range is suitable for the standard ranges of flexible and semi-rigid cables and is also available as a PCB mounted version. The connectors are usable up to a frequency of 3 GHz. It also prescribes mating face dimensions for grade 2 general purpose connectors, dimensional detail of grade 0 standard test connectors, gauging information and tests selected from IEC 61169-1 applicable to all detail specifications relating to SSMB series RF connectors. It indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. This first edition cancels and replaces IEC/PAS 61169-19, published in 2009, of which it constitutes a minor revision. The only change is that the PAS has been changed into and International Standard. French version of this publication was not submitted to the vote.
- Status
- Published
- Publication Date
- 26-Jan-2011
- Technical Committee
- SC 46F - RF and microwave passive components
- Drafting Committee
- PT 61169-19 - TC 46/SC 46F/PT 61169-19
- Current Stage
- PPUB - Publication issued
- Start Date
- 27-Jan-2011
- Completion Date
- 15-Apr-2011
Overview
IEC 61169-19:2011 is an international standard published by the International Electrotechnical Commission (IEC) that specifies the sectional requirements for radio frequency (RF) coaxial connectors of type SSMB. These connectors are characterized by their 50-ohm impedance, snap-on coupling mechanism, compact size, lightweight design, and reliable electrical performance. IEC 61169-19 provides detailed rules and guidelines essential for preparing the detail specification of SSMB connectors, including dimensional data, testing procedures, and quality assessment methodologies.
This standard covers SSMB connectors designed for low power miniature applications, suitable for flexible and semi-rigid cables as well as PCB mounting. They operate efficiently at frequencies up to 3 GHz, making them ideal for various RF communication and electronic systems.
Key Topics
Connector Characteristics
- 50-ohm characteristic impedance ensuring signal integrity.
- Miniature and lightweight design with convenient snap-on coupling.
- Compatibility with flexible cables, semi-rigid cables, and PCB mounting options.
- Operational frequency range up to 3 GHz.
Dimensional Specifications
- Mating face dimensions for Grade 2 general purpose connectors.
- Dimensional details for Grade 0 standard test connectors.
- Gauging instructions to ensure mechanical and electrical performance.
- Detailed figures and tables specifying connector dimensions such as pin and socket centre contacts.
Performance and Testing
- Recommended performance characteristics for incorporation into detailed specifications.
- Test schedules including acceptance and periodic testing to verify conformity.
- Inspection requirements tailored for quality assessment levels M (medium) and H (high).
- Tests selected in line with IEC 61169-1 standards ensuring uniform evaluation.
Quality Assessment
- Procedures for quality conformance inspections.
- Qualification approval processes and maintenance.
- Guidelines for selecting test conditions and severities to ensure reliable connector performance.
Preparation Guidelines
- Instructions for preparing detailed specifications for SSMB connectors.
- Pro forma blank detail specification included to aid manufacturers and users.
- Marking and ordering information procedures to standardize identification.
Applications
SSMB connectors standardized under IEC 61169-19:2011 are highly suitable for various RF applications requiring miniature, reliable, and high-frequency connectors:
Telecommunications
Used in radio, mobile networks, and data communication systems where compact connectors with excellent electrical performance are essential.Instrumentation and Test Equipment
Ideal for measurement instruments that require frequent mating and demating with low power RF signals.Military and Aerospace
Reliable for lightweight, compact RF connectors needed in defense communication and avionics systems.Consumer Electronics
Supports high-frequency signal connections in wireless devices and other compact electronic products.PCB Assemblies
Provides board-mounted RF connectivity for compact device designs.
Related Standards
IEC 61169-19:2011 is part of the larger IEC 61169 series covering radio-frequency connectors:
IEC 61169-1
Generic specification for RF connectors - general requirements and measuring methods, which forms the basis for the tests and quality procedures in IEC 61169-19.Other parts of IEC 61169 cover different types of RF connectors such as SMA, SMB, and N series, providing dimensional and performance specifications for those connector types.
Related IEC standards on cable assemblies and testing ensure that connectors can be integrated effectively within broader RF systems.
Summary
IEC 61169-19:2011 is a critical international standard that defines comprehensive and uniform requirements for SSMB series RF coaxial connectors. Its detailed specifications on dimensions, performance, and testing ensure that manufacturers and users achieve high-quality, reliable connectors suitable for applications up to 3 GHz frequency. By adhering to IEC 61169-19, industries benefit from standardized measurements, consistent connector interfaces, and enhanced interoperability, facilitating global communication and electronic systems development.
Keywords: IEC 61169-19, SSMB connectors, RF coaxial connectors, 50-ohm impedance, radio-frequency connectors, snap-on coupling, miniature RF connectors, RF connector testing, IEC RF connector standards, 3 GHz connectors, PCB mounted connectors, flexible cable connectors.
Relations
- Effective Date
- 05-Sep-2023
- Effective Date
- 05-Sep-2023
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.

UL Solutions
Global safety science company with testing, inspection and certification.
Sponsored listings
Frequently Asked Questions
IEC 61169-19:2011 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Radio-frequency connectors - Part 19: Sectional specification - Radio frequency coaxial connectors of type SSMB". This standard covers: IEC 61169-19:2011 is a sectional specification. It provides information and rules for preparation of detail specification of SSMB series R.F connectors together with the pro forma blank detail specification The SSMB series connectors with characteristic impedance 50 ohm are one kind of low power miniature connectors with snap-on coupling mechanism and have the characteristics of light weight, small size, convenient connection and excellent characteristics. This connector range is suitable for the standard ranges of flexible and semi-rigid cables and is also available as a PCB mounted version. The connectors are usable up to a frequency of 3 GHz. It also prescribes mating face dimensions for grade 2 general purpose connectors, dimensional detail of grade 0 standard test connectors, gauging information and tests selected from IEC 61169-1 applicable to all detail specifications relating to SSMB series RF connectors. It indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. This first edition cancels and replaces IEC/PAS 61169-19, published in 2009, of which it constitutes a minor revision. The only change is that the PAS has been changed into and International Standard. French version of this publication was not submitted to the vote.
IEC 61169-19:2011 is a sectional specification. It provides information and rules for preparation of detail specification of SSMB series R.F connectors together with the pro forma blank detail specification The SSMB series connectors with characteristic impedance 50 ohm are one kind of low power miniature connectors with snap-on coupling mechanism and have the characteristics of light weight, small size, convenient connection and excellent characteristics. This connector range is suitable for the standard ranges of flexible and semi-rigid cables and is also available as a PCB mounted version. The connectors are usable up to a frequency of 3 GHz. It also prescribes mating face dimensions for grade 2 general purpose connectors, dimensional detail of grade 0 standard test connectors, gauging information and tests selected from IEC 61169-1 applicable to all detail specifications relating to SSMB series RF connectors. It indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H. This first edition cancels and replaces IEC/PAS 61169-19, published in 2009, of which it constitutes a minor revision. The only change is that the PAS has been changed into and International Standard. French version of this publication was not submitted to the vote.
IEC 61169-19:2011 is classified under the following ICS (International Classification for Standards) categories: 29.080.10 - Insulators; 33.120.30 - RF connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 61169-19:2011 has the following relationships with other standards: It is inter standard links to IEC PAS 61169-19:2009, IEC 60169-19:1985. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 61169-19:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC 61169-19 ®
Edition 1.0 2011-01
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 19: Sectional specification – Radio frequency coaxial connectors of type
SSMB
Connecteurs pour fréquences radioélectriques –
Partie 19: Spécification intermédiaire – Connecteurs coaxiaux pour fréquences
radioélectriques de type SSMB
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 61169-19 ®
Edition 1.0 2011-01
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Radio-frequency connectors –
Part 19: Sectional specification – Radio frequency coaxial connectors of type
SSMB
Connecteurs pour fréquences radioélectriques –
Partie 19: Spécification intermédiaire – Connecteurs coaxiaux pour fréquences
radioélectriques de type SSMB
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX U
ICS 33.120.30 ISBN 978-2-88912-320-9
– 2 – 61169-19 IEC:2011
CONTENTS
FOREWORD . 4
1 Scope . 6
2 Normative references . 6
3 Mating face and gauge information . 6
3.1 Dimensions – General purpose connectors – Grade 2 . 6
3.1.1 Connector with socket-centre contact . 6
3.1.2 Connector with pin-centre contact . 8
3.2 Gauges . 9
3.2.1 Gauge pins for socket-centre contact . 9
3.2.2 Test procedure . 9
3.2.3 Gauge for outer contact of socket-centre contact . 10
3.2.4 Test procedure . 10
3.3 Dimensions – Standard test connectors – Grade 0 . 11
3.3.1 Connector with socket-centre contact . 11
3.3.2 Connector with pin-centre contact . 12
4 Quality assessment procedure . 13
4.1 General . 13
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1) . 13
4.3 Test schedule and inspection requirements – Acceptance tests . 15
4.3.1 Acceptance tests . 15
4.3.2 Periodic tests . 16
4.4 Procedures . 18
4.4.1 Quality conformance inspection . 18
4.4.2 Qualification approval and its maintenance . 18
5 Instructions for preparation of detail specifications . 18
5.1 General . 18
5.2 Identification of the component . 18
5.3 Performance . 19
5.4 Marking, ordering information and related matters . 19
5.5 Selection of tests, test conditions and severities . 19
5.6 Blank detail specification pro-forma for type SSMB connector . 20
Figure 1 – Connector with socket-centre contact (for dimensions and notes, see Table 1) . 7
Figure 2 – Connector with pin-centre contact (for dimensions and notes, see Table 2) . 8
Figure 3 – Gauge pins for socket-centre contact (for dimensions and notes, see Table 3) . 9
Figure 4 – Outer contact sizing and retention force gauges A and B (for dimensions
and notes, see Table 4) . 10
Figure 5 – Connector with socket-centre contact (for dimensions and notes, see Table 5) . 11
Figure 6 – Connector with pin-centre contact (for dimensions and notes, see Table 6) . 12
Table 1 – Dimensions of connector with socket-centre contact . 7
Table 2 – Dimensions of connector with pin-centre contact . 8
Table 3 – Dimensions of gauge pins for socket-centre contact . 9
Table 4 – Dimensions of gauge for outer contact . 10
Table 5 – Dimensions of connector with socket-centre contact . 11
61169-19 IEC:2011 – 3 –
Table 6 – Dimensions of connector with pin-centre contact . 12
Table 7 – Rating and characteristics . 13
Table 8 – Acceptance tests . 15
Table 9 – Periodic tests . 16
– 4 – 61169-19 IEC:2011
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 19: Sectional specification –
Radio frequency coaxial connectors of type SSMB
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61169-19 has been prepared by subcommittee 46F: R.F. and
microwave passive components, of IEC technical committee 46: Cables, wires, waveguides,
R.F. connectors, R.F. and microwave passive components and accessories.
This first edition cancels and replaces IEC/PAS 61169-19, published in 2009, of which it
constitutes a minor revision. The only change is that the PAS has been changed into and
International Standard.
The text of this standard is based on the following documents:
CDV Report on voting
46F/138/CDV 46F/163/RVC
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
61169-19 IEC:2011 – 5 –
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 61169 series, published under the general title Radio-frequency
connectors, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The “colour inside” logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct understanding
of its contents. Users should therefore print this publication using a colour printer.
– 6 – 61169-19 IEC:2011
RADIO-FREQUENCY CONNECTORS –
Part 19: Sectional specification –
Radio frequency coaxial connectors of type SSMB
1 Scope
The SSMB series connectors with characteristic impedance 50 Ω are one kind of low power
miniature connectors with snap-on coupling mechanism and have the characteristics of light
weight, small size, convenient connection and excellent characteristics. This connector range
is suitable for the standard ranges of flexible and semi-rigid cables and is also available as a
PCB mounted version. The connectors are usable up to a frequency of 3 GHz.
This sectional specification provides information and rules for preparation of detail
specification of SSMB series R.F connectors together with the pro forma blank detail
specification.
It also prescribes mating face dimensions for grade 2 general purpose connectors,
dimensional detail of grade 0 standard test connectors, gauging information and tests
selected from IEC 61169-1 applicable to all detail specifications relating to SSMB series RF
connectors.
This specification indicates recommended performance characteristics to be considered when
writing a detail specification and it covers test schedules and inspection requirements for
assessment levels M and H.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
requirements and measuring methods
Amendment 1 (1996)
Amendment 2 (1997)
3 Mating face and gauge information
3.1 Dimensions – General purpose connectors – Grade 2
3.1.1 Connector with socket-centre contact
All non-dimensioned pictorial configurations are for reference purpose only.
___________
There exists a consolidated edition 1.2 (1998) that comprises IEC 61169-1:1992, its Amendment 1:1996 and
its Amendment 2:1997.
61169-19 IEC:2011 – 7 –
Note 1
f
i
d e
h
Note 3
j
Note 4
IEC 058/11
Figure 1 – Connector with socket-centre contact
(for dimensions and notes, see Table 1)
Table 1 – Dimensions of connector with socket-centre contact
mm
Ref.
Min. Max.
a 2,74 -
b -
c - 1,34
d - 1,78
e 0,84 -
f 0,84 -
g 2,11 (nominal)
h 3,10 -
i 0,00 -
j 2,77 -
NOTE 1 Reference plane.
NOTE 2 The form and dimension of outer contact detent
meet electrical and mechanical performance requirements.
NOTE 3 The diameters are chosen upon the assumption that
the PTFE dielectric has a dielectric constant of 2,02 to give an
impedance of 50 Ω.
NOTE 4 Resilient contact may be closed or open entry,
method of resilience is optional, provided that when a pin of
0,36 mm to 0,38 mm diameter is inserted, VSWR mating and
endurance performances are obtained.
∅a
∅b (Note 2)
∅c
∅g
– 8 – 61169-19 IEC:2011
3.1.2 Connector with pin-centre contact
Note 1
See detail A
k
l
m
n
u
s
t
Note 2
w
x
Detail A
IEC 059/11
Figure 2 – Connector with pin-centre contact
(for dimensions and notes, see Table 2)
Table 2 – Dimensions of connector with pin-centre contact
mm
Ref.
Min. Max.
k - 3,10
l 1,91 -
m - 0,84
n 0,00 -
p 2,11 (nominal)
q 1,37 -
r - 2,67
s 0,00 -
t 0,71 0,74
u 88º~92º
v 0,05 0,15
w - 2,75
x 1,91 -
y - 0,25
z 0,36 0,38
NOTE 1 Reference plane.
NOTE 2 The diameters are chosen upon the assumption that
the PTFE dielectric has a dielectric constant of 2,02 to give an
impedance of 50 Ω.
∅p
∅y
∅q
∅z
∅r
v
61169-19 IEC:2011 – 9 –
3.2 Gauges
3.2.1 Gauge pins for socket-centre contact
50° ± 2°
∅a
∅0,20 mm max.
Blend radius
R0,4 mm max.
IEC 055/11
Figure 3 – Gauge pins for socket-centre contact
(for dimensions and notes, see Table 3)
Table 3 – Dimensions of gauge pins for socket-centre contact
Gauge A Gauge B
Ref.
Maximum material for sizing Minimum material for measurement of retention
purposes force
mm mm
Min. Max. Min. Max.
a 0,381 0,384 0,353 0,356
b 1,70 1,80 1,70 1,80
Material: steel, polished, surface roughness: Ra=0,4 µm maximum.
Mass of gauge: 16 g ± 1 g
3.2.2 Test procedure
The gauge A shall be inserted into the socket-centre contact three times with a minimum
depth of b .
This is a sizing operation and should only be carried out when the socket-centre contact is
removed from the connector.
After this, the gauge B shall be inserted into socket-centre contact. The contact shall retain
the mass of the gauge in a vertical downward position.
This test also shall be carried out on connector when the socket-centre contact is not
removed.
b
– 10 – 61169-19 IEC:2011
3.2.3 Gauge for outer contact of socket-centre contact
a
g radius or
b
chamfer permissible
d radius
e radius f radius
k
Reference plane
j
IEC 060/11
Figure 4 – Outer contact sizing and retention force gauges A and B
(for dimensions and notes, see Table 4)
Table 4 – Dimensions of gauge for outer contact
Ref Gauge A (maximum Gauge B (minimum material for
material for sizing measurement of gauge retention
purpose) force)
mm mm
Min. Max. Min. Max.
a 0,74 0,75 0,58 0,64
b 0,48 0,51 0,43 0,46
c 0,14 0,15 0,075 0,125
d - 0,08 - 0,08
e 0,08 0,18 0,08 0,18
f 0,2 0,4 0,2 0,4
g - 0,38 - 0,38
h 1,68 - 1,68 -
i 2,672 2,675 2,667 2,670
k 3,05 3,10 3,05 3,10
j 3,50 - 3,50 -
Material: steel, polished, surface roughness: Ra=0,4 µm maximum.
Mass of gauge: 460 g ± 20 g
3.2.4 Test procedure
The gauge A shall be inserted into the outer contact of the socket-centre contact three times.
This is a sizing operation.
After this, the gauge B shall be inserted into the outer contact of the socket-centre contact.
The contact shall support the mass of the gauge in a vertical downward position.
c
∅h
∅i
61169-19 IEC:2011 – 11 –
NOTE Additional test: Following the sizing operation, the force necessary to insert gauge A into the outer contact
of the socket-centre contact is measured. When this test is required, the maximum permitted insertion force is then
specified and is smaller than 27 N.
3.3 Dimensions – Standard test connectors – Grade 0
3.3.1 Connector with socket-centre contact
Note 1
A
∅0,12 mm
Note 2
e
d h
i g
0,012 mm
A
0,010 mm A
B
∅0,07 mm
Note 2
k
B
Note 3
IEC 061/11
Figure 5 – Connector with socket-centre contact
(for dimensions and notes, see Table 5)
Table 5 – Dimensions of connector with socket-centre contact
Ref. mm
Min. Max.
a 2,740 2,840
b 2,464 2,514
c 1,295 1,340
d - 1,780
e 0,000 0,127
f
2,110(nominal)
g 0,000 0,127
h 0,840 0,942
i 3,100 3,150
k 2,770 -
NOTE 1 Reference plane.
NOTE 2 The diameters are chosen upon the assumption that the PTFE
dielectric has a dielectric constant of 2,02 to give an impedance of
∅a
∅b
∅c
∅f
– 12 – 61169-19 IEC:2011
50 Ω ± 0,5 Ω.
NOTE 3 Resilient contact may be closed or open entry, method of
resilience optional, provided that when a pin of 0,36 mm to 0,38 mm
diameter is inserted, VSWR mating and endurance performances are
obtained.
3.3.2 Connector with pin-centre contact
Note 1
See detail A
l
Note 2
m
n
p
x
A
∅0,12 mm A
r
q
t
Note 2
y
z
Detail A
B
∅0,075 mm
B
IEC 062/11
Figure 6 – Connector with pin-centre contact
(for dimensions and notes, see Table 6)
Table 6 – Dimensions of connector with pin-centre contact
Ref. mm
Min. Max.
l 3,050 3,100
m 1,905 -
n 0,740 0,840
p 0,000 0,127
q 0,710 0,740
r 89° to 91°
s 0,120 0,150
t 0,080 radius
u
2,110(nominal)
v 1,370 1,420
w 2,620 2,670
x 0,000 0,050
y - 2,750
z 1,910 -
∅u
∅aa
∅ab
∅v
∅w
s
61169-19 IEC:2011 – 13 –
Ref. mm
Min. Max.
aa - 0,250
ab 0,360 0,380
NOTE 1 Reference plane.
NOTE 2 The diameters are chosen upon the assumption that
the PTFE dielectric has a dielectric constant of 2,02 to give
an impedance of 50 Ω ± 0,5 Ω.
4 Quality assessment procedure
4.1 General
The following subclauses provide recommended rating, performance and test conditions to be
considered when writing a detail specification. They also provide an appropriate schedule of
tests with minimum levels of conformance inspection sampling, together with the pro-forma
blank detail specification (BDS) and instructions for the preparation of a detail specification.
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1)
The values indicated below are recommended for SSMB series RF connectors and are given
for the writer of the detail specification. They are applicable for the condition when the
connectors are fully mated.
Certain tests are listed without any recommended values being given. These tests will usually
not be required. When these tests are required, appropriate values shall be entered in the
detail specification at the discretion of the specification writer.
Table 7 – Rating and characteristics
Remarks,
IEC 61169-1 deviations from
Rating and characteristics Values
Subclause standard test
method
Electrical
Nominal impedance 50 Ω
Frequency range Up to 3 GHz
a
Reflection factor 9.2.1
Grade 2 connectors
– straight styles Up to 1 GHz
≤0,1
Up to 3 GHz
≤0,15
– right-angle styles Up to 1 GHz
≤0,2
Up to 3 GHz
≤0,24
– component mounting styles
See DS
– solder bucket and PCB mounting styles
See DS
b
Centre contact resistance 9.2.3
– initial
≤ 5,0 mΩ
– after conditioning
≤ 15,0 mΩ
b
Outer conductor continuity 9.2.3
– initial ≤ 2,5 mΩ
– after conditioning
≤ 7,5 mΩ
a
Insulation resistance 9.2.5
– initial
≥ 1 000 MΩ
– after conditioning
≥ 200 MΩ
– 14 – 61169-19 IEC:2011
Remarks,
IEC 61169-1 deviations from
Rating and characteristics Values
Subclause standard test
method
c d
Proof voltage at sea level 9.2.6 500 V
c d
Proof voltage at 4,4 kPa 9.2.6 100 V 4,4 kPa
approximately
equivalent to 20 km
c d
Environmental voltage at sea level 250 V
c d
Environmental voltage at 4,4 kPa 85 V 4,4 kPa
approximately
equivalent to 20 km
Screening effectiveness (straight cables 9.2.8
≥ 40 dB at
f
only)
1 GHz
Mechanical
Gauge retention force (resilient contacts) 9.3.4
– centre contact ≥ 0,15 N
– outer contact
≥ 4,5 N
Centre contact captivation 9.3.5
– axial force Maximum
≥ 8,9 N
displacement
0,25 mm in each
direction
Engagement and separation 9.3.6
– separation force
≥ 4,5 N
– insertion force
≤ 27 N
Mechanical tests on cable fixing
– cable rotation (nutation) 9.3.7.2 See DS
– cable pulling 9.3.8 See DS
– cable bending 9.3.9 See DS
– cable torsion 9.3.10 See DS
Bending moment 9.3.12 See DS
Vibration 9.3.3 100 m/s 10 g
n
10 Hz ~500 Hz
Shock 9.3.14
See DS
Environmental
Climatic category 9.4.2 A:55/125/21
B:40/085/21
Sealing non-hermetic 9.4.5.1 100 kPa to 110 kPa
≤100 kPa·cm /h
differential
Hermetic 9.4.5.2 100 kPa to 110 kPa
–3 3
≤10 Pa·cm /s
differential
Salt mist 9.4.6 48 h spray
Endurance
Mechanical endurance 9.5 500 operations
e
High temperature endurance 9.6 Category A:
250 h at 125 °C
Category B:
250 h at 85 °C
61169-19 IEC:2011 – 15 –
a
These values apply to basic connector. In practice, these may be influenced by the cable used and
reference should always be made to the actual values given in the detail specification.
b
Values for a single pair of connectors.
c
Voltages are r.m.s. values of a.c. at 40 Hz to 65 Hz, unless otherwise specified.
d
Some cables usable with these connectors have ratings lower than the values given here.
e
For certain connectors, the upper temperature limit is restricted by the cable characteristics. Reference
should be made to the relevant cable specification. When semi-rigid and semi-flexible cables are used, the
upper temperature is limited to 115 °C maximum.
f
When interfaces are fully mated.
4.3 Test schedule and inspection requirements – Acceptance tests
4.3.1 Acceptance tests
Table 8 – Acceptance tests
Test method Assessment level M (higher) Assessment level H (lower)
Test Test
IEC61169-1
IL AQL % Period IL AQL % Period
required required
subclause
Group A1
Visual 9.1.2 a II 1,0 S-3 1,5
a
examination
Group B1
Lot Lot
Outline dimension 9.1.3.1 a S-4 0,40 a S-3 4,0
Mechanical
compatibility
9.1.3.3 a II 1,0 a S-3 1,5
By By
Engagement and
separation
9.3.6 a S-4 0,40 a S-3 1,5
Gauge retention 9.3.4 ia II 1,0 Lot ia S-3 1,5 Lot
(resilient contacts)
Sealing
non-hermetic 9.4.5.1 ia II 0,65 ia S-3 1,0
hermetic 9.4.5.2 ia II 0,015 ia II 0,025
Voltage proof 9.2.6 a S-4 0,40 a II 4,0
Solderability (d) 9.3.2.1.1 ia S-4 0,40 ia S-3 4,0
Insulation 9.2.5 a S-4 0,40 a S-3 4,0
resistance
For the symbols, abbreviations and procedures, see the end of Table 9.
– 16 – 61169-19 IEC:2011
4.3.2 Periodic tests
There are no group C tests for levels H and M.
Table 9 – Periodic tests
Test Assessment level M (higher) Assessment level H (lower)
method
Test Number of Permitted Period Test Number of Permitted Period
IEC 61169-1
required specimens failures required specimens failures
subclause
per per
a a
group group
Group D1 (d)
Solderability 9.3.2.1.1 ia ia
– connector
assemblies
Resistance to 9.3.2.1.2 ia ia
soldering heat
Mechanical
tests on cable
fixing
ia ia
– cable 9.3.7.2
3 3
rotation
6 1 3 1
years years
(nutation)
– cable 9.3.8
ia ia
pulling
– cable 9.3.9
ia ia
bending
– cable 9.3.10
ia ia
torsion
Bending 9.3.12 a a
moment
Strength of 9.3.11 ia ia
coupling
mechanism
Group D2 (d)
Contact a
9.2.3 a
resistance
Outer
conductor and
screen
continuity
9.2.3
Centre
conductor
3 3
6 1 3 1
continuity
years years
Bump 9.3.13 na na
Vibration 9.3.3 a a
Shock 9.3.14 a a
Damp heat, 9.4.3 a a
steady state
Salt mist 9.4.6 a a
Group D3
b b
Dimensions 9.1.3.2 a 3 a 3
1 1
1 1
piece part and years years
materials
61169-19 IEC:2011 – 17 –
Test Assessment level M (higher) Assessment level H (lower)
method
Test Number of Permitted Period Test Number of Permitted Period
IEC 61169-1
required specimens failures required specimens failures
subclause
per per
a a
group group
Group D4 (d)
Mechanical 9.5 a a
endurance
3 3
High 9.6 a a
6 1 3 1
years years
temperature
endurance
Sulphur 9.4.8 na na
dioxide
Group D5 (d)
Reflection 9.2.1 a a
factor
3 3
Screening 9.2.8 a 6 1 a 3 1
years years
effectiveness
Water 9.2.7 ia ia
Immersion
Group D6 (d)
Contact 9.3.5 ia ia
Captivation
Discharge test 9.2.9 a a
(corona effect)
3 3
6 1 3 1
years years
Rapid change 9.4.4 a a
of
temperature
Climatic
9.4.2 a a
sequence
Group D7 (d)
c c
Resistance to 9.7 na 1 1 3 na 1 1 3
solvents and years years
contamination
fluids
ABBREVIATIONS:
a - applicable.
na - not applicable.
ia - test required (if technically applicable).
(d) - destructive test - specimens shall not be returned to stock.
IL - inspection level.
AQL- acceptable quality level.
a
For qualification approval a total of 2 failures only permitted for level H and 1 failure only permitted for level M
from groups D1 to D7.
b
One set of piece parts each style and variant unless using common piece parts.
c
Group D7 - number of pairs for each solvent.
– 18 – 61169-19 IEC:2011
4.4 Procedures
4.4.1 Quality conformance inspection
This shall consist of test group A1 and B1 on a lot-by-lot basis and test group D1 to D7 on a
periodic basis.
4.4.2 Qualification approval and its maintenance
This still consists of three consecutive lots passing test groups A1 and B1 followed by
selection of specimens from the lots as appropriate. These specimens shall successfully pass
the specified periodic D tests.
5 Instructions for preparation of detail specifications
5.1 General
Detail specifications (DS) writers shall use the appropriate BDS pro-forma. The following
pages comprise the pro-forma BDS dedicated for use with 50 Ω type SSMB connectors. As
such, it will already have entered on it information relating to
a) the basic specification number applicable to all the detail specifications covering
connector styles of the type covered by the sectional specification;
b) the connector series designation.
The specification writer should enter the details relating to the connector style/variant(s) to be
covered as indicated. The numbers in brackets on the BDS pro-forma correspond to the
following indications which shall be given.
5.2 Identification of the component
(5) Enter the following details:
Style: The style designation of the connector including type of
fixing and sealing, if applicable.
Attachment: By deletion of the inapplicable options of cable/wire: given
for centre and outer conductors.
Special features and markings: As applicable.
(6) Enter details of assessment level and the climatic category.
(7) A reproduction of the outline drawing and details of the panel piercing, if applicable. It
shall provide the maximum envelope dimensions, also the position of the reference
plane and, in the case of a fixed connector, the position of the mounting plane(s)
relative to the front face of the connector.
Any maximum panel thickness limitations for fixed connectors shall be stated.
(8) Particulars of all variants covered by the DS. As appropriate, the information shall
include:
• cable types (or sizes) applicable to each variant;
• alternative plated or protective finishes;
• details of alternative mounting flanges having either tapped or plain mounting holes;
• details of alternative solder spills or solder buckets including, when applicable,
those for use with microwave integrated circuit (MIC) components.
61169-19 IEC:2011 – 19 –
5.3 Performance
(9) Performance data listing the most important characteristics of the connector taking into
account the recommended values in 4.2 of this specification. Deviations from the
minimum requirements shall be clearly indicated. Non-applicable parameters shall be
marked ‘na’.
5.4 Marking, ordering information and related matters
(10) Insert marking and ordering information as appropriate, together with details of related
documents and any invoked structural similarity.
5.5 Selection of tests, test conditions and severities
(11) ‘na’ shall be used to indicate non-applicable tests. All tests marked ‘a’ by the detail
specification writer shall be mandatory.
When using the normal procedure with a dedicated BDS, the letter ‘a’ – for applicable –
shall be entered in the ‘Test required’ column against each of the tests indicated as
being mandatory in the test schedule as in 4.3 of this specification. Any additional tests
required at the discretion of the specification writer shall also be indicated by an ‘a’.
The specification writer shall also indicate, when necessary, details of deviations from
the standard test methods and test conditions, including any relevant deviations given in
the test schedule of the sectional specification.
The qualification approval and conformance inspection shall be such that the national
supervising inspectorate (NSI) shall be satisfied that they are appropriate and in line
with those for other connectors within the system providing a reasonably comparable
service.
– 20 – 61169-19 IEC:2011
5.6 Blank detail specification pro-forma for type SSMB connector
The following pages contain the complete BDS pro-forma.
(1)
Page 1 of 10
ELECTRONIC COMPONENT OF ASSESSED (4) ISSUE
QUALITY IN ACCORDANCE WITH
GENERIC SPECIFICATION IEC 61169-1 .
SECTIONAL SPECIFICATION IEC 61169-19
NATIONAL REFERENCE .
(5) Detail specification for type SSMB
Radio frequency coaxial connector of assessed quality
Style:. Special features and markings
Method of cable/wire+ attachment centre conductor – solder/crimp+
outer conductor – solder/clamp/crimp +
+ delete as appropriate
(6) Assessment level. Characteristic impedance 50 Ω Climatic category./././
(7) Outline and maximum dimensions Panel piercing and mounting details
(8) Variants
Variant No. Description of variant 61196 IEC
01. . . . . .
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. ............. .............
............. ............. ............. ............. .............
Information about manufacturers who have components qualified to this detail specification is available through
IECQ on-line certificate system.
61169-19 IEC:2011 – 21 –
(9) Performance (including limiting conditions of use)
Remarks including any
IEC 61169-1
Ratings and characteristics Value deviations from standard test
Subclause
methods
Electrical
Nominal impedance 50 Ω
Frequency range Measurement frequency range
0 GHz -3 GHz
Reflection factor 9.2.1
Variant No.
...........
Designation .
...........
01. .
........... ............
Centre contact resistance 9.2.3 ≤ .mΩ Initial
After conditioning
≤.mΩ
Centre conductor 01. 9.2.3 Resistance change due to
.............mΩ
continuity . conditioning
.............mΩ
............
.............mΩ
..............
.............mΩ
Outer contact continuity 9.2.3
≤ .mΩ Initial
After conditioning
≤.mΩ
Insulation resistance 9.2.5 Initial
≥.GΩ
After conditioning
≥.GΩ
#+ Proof voltage at sea 01. 9.2.6 .kV 86 kPa -106 kPa
level . .kV
............ ..............kV
.............. ..............kV
#+ Proof voltage at 01. .V .kPa (if not 4,4 kPa)
4,4 kPa . .V
............ ...............V
.............. ...............V
#+ Environment test 01. .V 86 kPa -106 kPa
voltage at sea level . .V
............ ...............V
.............. ...............V
Environment test voltage 01. .V .kPa (if not 4,4 kPa)
at 4,4 kPa . .V
............ ...............V
.............. ...............V
Screening effectiveness 01. 9.2.8 ≥ dB at.GHz Z≤.Ω
t
...........
............
..............
ADDITIONAL
ELECTRICAL
CHARACTERISTICS
+ Voltage values are r.m.s. values at 50 Hz - 60 Hz, unless otherwise specified.
– 22 – 61169-19 IEC:2011
Remarks including any
IEC 61169-1
Ratings and characteristics Value deviations from standard test
Subclause
methods
Mechanical
Soldering 9.3.2.1.1
- bit size .
Gauge retention resilient For gauging detail, see Figure 3
contacts 9.3.4 and Table 3
...............
- inner contact
- outer contact
Centre contact captivation 9.3.5
- axial force .N
- permitted displacement .mm
each direction
Engagement and 9.3.6
Achievable by hand
separation
- axial force
Effectiveness of cable
fixing against
- cable rotation 01. 9.3.7.2 Rotations
........... .................
............ ..................
.............. .................
- cable pulling 01. 9.3.8 .N
Point of application and duration
........... ...........
………mm………s
............ ............
.............. ..............
………mm………s
………mm………s
………mm………s
- cable bending 01. 9.3.9 .Cycles Length of cable mass
........... ........... ................. ..........
............ ............ ................. ..........
.............. .............. ................. ..........
- cable torsion 01. 9.3.10 .Nm
Duration of applied torque
........... ...........
…………s
............ ............
.............. ..............
…………s
…………s
…………s
…………s
Bending moment 9.3.12 .Nm Relative to reference plane
Vibration 9.3.3 .m/s (.g acceleration)
n
......to....Hz
ADDITIONAL
MECHANICAL
CHARACTERISTICS
61169-19 IEC:2011 – 23 –
Remarks including any
IEC 61169-1
Ratings and characteristics Value deviations from standard test
Subclause
methods
Environmental
Climatic category ././.
Sealing non-hermetically 9.4.5.1 .cm /h 100 kPa -110 kPa pressure
sealed connectors differential
–5 3
Sealing hermetically sealed 9.4.5.2 10 bar/cm /h 100 kPa -110 kPa pressure
connectors differential
Water immersion 9.2.7
Salt mist 9.4.6 ….…….h Duration of spraying
ADDITIONAL
ENVIRONMENTAL
CHARACTERISTICS
ENDURANCE
Mechanical 9.5 ….operations
High temperature 9.6 .h
at.°C
ADDITIONAL ENDURANCE
CHARACTERISTICS
CHEMICAL CONTAMINATION
Resistance to solvents and 9.7 .
contaminating fluids to be .
used .
Applicable fluids
Sulphur dioxide 9.4.8
– 24 – 61169-19 IEC:2011
(10) Supplementary information
– Marking of the component: in accordance with 11.1 of IEC 61169-1 in the following
order of preference:
1) Manufacturer code: .
2) Manufacturing date code: year/week
3) Component identification: Variant No./ Identification
Designation
..................................
..................................
..................................
..................................
..................................
..................................
..................................
...................................
– Marking and contents of package: in accordance with 11.2 of IEC 61169-1
1) Information prescribed in 11.1 of IEC 61169-1 detailed above
2) Nominal characteristic impedance .50 Ω.
3) Assessment level code letter .
4) Any additional marking required .
Ordering information
1) Number of the detail specification …………………./Variant code.
2) Assessment level code letter .
3) Body finish (if more than one listed) .
4) Any additional information or
special requirements .
– Related documents (if not included in IEC 61169-1 or sectional specification):
............................................................................................................
.............................................................................................................
– St
...