91.120 - Protection of and in buildings
ICS 91.120 Details
Protection of and in buildings
Schutz von und in Gebauden
Protection exterieure et interieure des batiments
Zaščita stavb in v stavbah
General Information
e-Library Subscription
Create subscription and get permanent access to documents within 91.120 - Protection of and in buildings
Currently subscription includes documents marked with .We are working on making all documents available within the subscription.
This document explains the relationship of the ISO 22762 series to the design and testing of seismic isolation systems, including the relationship to national seismic codes.
- Technical report40 pagesEnglish languagesale 15% off
This standard defines procedures to measure in laboratory the impact sound level reduction of isolated heavy landings connected to a heavy wall, isolated heavy flights of stairs connected to a heavy landing, floor or ceiling, and lightweight stairs connected to a heavy wall, floor or ceiling.
This standard also considers the characterization of isolating elements for heavy landings or heavy flights of stairs in terms of an insertion loss expressed as an impact sound level difference. The corresponding procedure is given in a normative annex (Annex A), separated from the other procedures for the sake of clarity.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the steady-state data analysis methods to evaluate the data from ‘the aggregate heat loss test method’. These analysis methods enable the actual in situ aggregate heat loss (building heat transfer coefficient) to be estimated.
NOTE The aggregate heat loss method is specified in prEN 17888-1:2022, Thermal performance of buildings - In situ testing of building test structures - Part 1: Data collection for aggregate heat loss test.
- Standard52 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method for the in situ measurement of the thermal performance of buildings, both newly built and existing.
This document specifies the data to be collected during and after the test.
NOTE The analysis of the data and the reporting format for the analysis are referred to in prEN 17887-2:2022 Thermal performance of buildings - In situ testing of completed buildings - Part 2: Steady-state data analysis for aggregate heat loss test.
This document is applicable to domestic scale detached buildings and attached domestic scale buildings, such as semi-detached houses, terraced houses and apartments.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method for the in situ testing of the thermal performance of building structures especially built for the purpose of the test.
This document also specifies the apparatus to be used and the measurement procedures to collect the data and the reporting format for the apparatus including the building test structure and the test conditions.
NOTE The analysis of the data and the reporting format for the analysis are referred to in prEN 17888-2.
This document does not apply to:
- existing buildings;
- building structures allowing direct solar gains through glazing surfaces;
- the determination of the thermal performance of a specific building product, material, component or element.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This document covers technical insulation systems of operational installations in industry and the building services, such as pipes, ducts, vessels, equipment and built-in components.
The document contains methods for the energy efficiency classification of insulation systems for above-mentioned components with an operational temperature range of -30 °C up to 650 °C.
The document addresses plant operators, engineers of operational installations as well as the involved contractors such as insulation contractors and pipefitting contractors.
The design of safe surface temperatures for personnel protection is outside the scope of this document. This document also does not apply to heating, cooling and ventilation systems in buildings and does not apply to directly buried district heating and district cooling pipes.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the steady-state data analysis methods to evaluate the data from ‘the aggregate heat loss test’. These analysis methods enable the actual in situ aggregate heat loss (building heat transfer coefficient) to be estimated.
NOTE The aggregate heat loss method is specified in prEN 17887-1:2022 Thermal performance of buildings - In-situ testing of completed buildings - Part 1: Data collection for aggregate heat loss test.
- Standard53 pagesEnglish languagesale 10% offe-Library read for1 day
This document is applicable to technical insulation systems of operational installations in industry and the building services, such as pipes, ducts, vessels, equipment and built-in components.
The document specifies methods for the energy efficiency classification of insulation systems for the abovementioned components with an operational temperature range of −30 °C up to 650 °C.
The document addresses plant operators, engineers of operational installations, as well as the involved contractors such as insulation contractors and pipefitting contractors.
The design of safe surface temperatures for personal protection, as well as the prevention of condensation, is outside the scope of this document.
This document also does not apply to water-based heating and cooling systems in buildings and does not apply to directly buried district heating and district cooling pipes.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 16032:2004 specifies methods for measuring the sound-pressure level produced by service equipment attached to or installed in buildings. It specifically covers measurements on sanitary installations, mechanical ventilation, heating and cooling service equipment, lifts, rubbish chutes, boilers, blowers, pumps and other auxiliary service equipment, and motor-driven car park doors, but can also be applied to other equipment attached to or installed in buildings.
The methods are suitable for rooms with volumes of approximately 300 cubic metres or less in e.g. dwellings, hotels, schools, offices and hospitals. The standard is not in general intended for measurements in large auditoria such as concert halls. However, the operating conditions and operating cycles in Annex B can be used in such cases.
The service equipment sound-pressure level is determined as the maximum A-weighted and optionally C-weighted sound-pressure level occurring during a specified operation cycle of the service equipment under test, or as the equivalent continuous sound-pressure level determined with a specified integration time. A-weighted and C-weighted values are calculated from octave-band measurements.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This document provides the product category rules (PCR) for Type III environmental declarations (as in EN 15804:2012+A2:2019+AC:2021) for factory made and in situ thermal insulation products.
Complementary to EN 15804:2012+A2:2019+AC:2021, the PCR described in this document:
- specify the declared unit to be used;
- define the system boundaries for thermal insulation products;
- specify/describe the default scenarios and rules for defining scenarios for certain life cycle information modules.
These PCR are intended to be used for cradle to gate, cradle to gate with options or cradle to grave assessment, provided the intention is properly stated in the system boundary description.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies procedures to measure in laboratory the impact sound level reduction of isolated heavy landings connected to a heavy wall, isolated heavy flights of stairs connected to a heavy landing, lower or upper floor, and lightweight stairs connected to a heavy wall, lower or upper floor.
This document also considers the characterization of isolating elements for heavy landings or heavy flights of stairs in terms of an insertion loss expressed as an impact sound level difference. The corresponding procedure is given in a normative annex (Annex A), separated from the other procedures for the sake of clarity.
The tests are performed in defined test configurations and the test results are firstly restricted to the test configurations as described in the test report. The data can be used for comparing the performance of products and as input for EN ISO 12354-2:2017, Annex F, to calculate the sound pressure levels produced by the same stairs and isolating elements when installed in buildings.
The test procedures defined in this document comprise the frequency range from 50 Hz to 5000 Hz.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This document describes a laboratory test method to determine the susceptibility of thermal insulation
products used for construction against mould growth under specified climatic conditions.
The method is applicable to both factory-made products and in situ formed products. Factory-made
products include panels, mats and rolls.
NOTE In situ formed products are usually those that are delivered loose and installed by blowing-in, pouring,
or spraying-on, eventually using water and/or binder, whether or not they are also treated using additives.
The test is carried out with one of the conditions described in Table 1.
This test method determines the susceptibility of a thermal insulation material to mould growth, but it
does not determine the suitability for use in a given design (wall, roof, etc.).
This method does not predict the resistance of an insulation product to water damage.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method for the in situ testing of the thermal performance of building structures especially built for the purpose of the test.
This document also specifies the apparatus to be used and the measurement procedures to collect the data and the reporting format for the apparatus including the building test structure and the test conditions.
NOTE The analysis of the data and the reporting format for the analysis are referred to in prEN 17888-2.
This document does not apply to:
- existing buildings;
- building structures allowing direct solar gains through glazing surfaces;
- the determination of the thermal performance of a specific building product, material, component or element.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the steady-state data analysis methods to evaluate the data from ‘the aggregate heat loss test method’. These analysis methods enable the actual in situ aggregate heat loss (building heat transfer coefficient) to be estimated.
NOTE The aggregate heat loss method is specified in prEN 17888-1:2022, Thermal performance of buildings - In situ testing of building test structures - Part 1: Data collection for aggregate heat loss test.
- Standard52 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the steady-state data analysis methods to evaluate the data from ‘the aggregate heat loss test’. These analysis methods enable the actual in situ aggregate heat loss (building heat transfer coefficient) to be estimated.
NOTE The aggregate heat loss method is specified in prEN 17887-1:2022 Thermal performance of buildings - In-situ testing of completed buildings - Part 1: Data collection for aggregate heat loss test.
- Standard53 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method for the in situ measurement of the thermal performance of buildings, both newly built and existing.
This document specifies the data to be collected during and after the test.
NOTE The analysis of the data and the reporting format for the analysis are referred to in prEN 17887-2:2022 Thermal performance of buildings - In situ testing of completed buildings - Part 2: Steady-state data analysis for aggregate heat loss test.
This document is applicable to domestic scale detached buildings and attached domestic scale buildings, such as semi-detached houses, terraced houses and apartments.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements for earthquake protection of automatic sprinkler systems in accordance with the EN 12845 series of standards. This document applies only to locations in earthquake zones in accordance to EN 1998-1:2004, 3.2.1 and for area subject to peak ground acceleration above 9 % of g. This document does not cover all legislative requirements. In certain countries specific national regulations apply and take precedence over this document. Users of this document are advised to inform themselves of the applicability or non-applicability for this document by their national responsible authorities
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 62561 specifies the requirements and tests for earthing enhancing compounds
producing low resistance of an earth termination system.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
This document provides the product category rules (PCR) for Type III environmental declarations (as in EN 15804:2012+A2:20191) for factory made and in situ thermal insulation products.
Complementary to EN 15804:2012+A2:20191, the PCR described in this document:
- specify the declared unit to be used;
- define the system boundaries for thermal insulation products;
- specify/describe the default scenarios and rules for defining scenarios for certain life cycle information modules.
These PCR are intended to be used for cradle to gate, cradle to gate with options or cradle to grave assessment, provided the intention is properly stated in the system boundary description.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62561-7:2024 is available as IEC 62561-7:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62561-7:2024 specifies the requirements and tests for earthing enhancing compounds producing low resistance of an earth termination system. This third edition cancels and replaces the second edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Figure A.1 has been replaced with a simpler one that clearly shows the high and low corrosion load limits of the earth enhancing compounds without the need for special knowledge; b) pH measurement has been introduced.
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies to nuclear power plants with water cooled reactors. For other nuclear facilities check the applicability of the document in advance, before it might be applied correspondingly. This document specifies the requirements for the earthquake safety of components. The operation-specific safety-related requirements for each component, e.g. load-bearing capacity (stability), integrity and functionality (see 4.1) are not the subject of this document. With regard to analysing the mechanical behaviour of the individual components and verifying the fulfillment of their safety related functions, additionally, the respective component-specific standards need to be consulted. In this document, the term "mechanical components" refers to components such as vessels, heat exchangers, pumps, valves, lifting gear, distribution systems and pipe lines including their support structures in as far as these components are not considered to be civil structures in accordance with ISO 4917-3. Liners, crane runways, platforms and scaffoldings are not considered as being part of these mechanical components. In this document, the term electrical components refers to the combination of electrical devices including all electrical connections and their support structures (e.g. cabinets, frames, consoles, brackets, suspensions or supports). Supplementary to this document the seismic qualification of electrical components is reported in IEC/IEEE 60980-344. NOTE This document is independent of national standards. Recommendations, given in Annex A, are mainly based on the Eurocodes-Design-Philosophy and European Standards. Alternatively other equivalent standards or regulations can be used in case the general requirements given in this document together with Annex A can be met.
- Standard36 pagesEnglish languagesale 15% off
This document specifies an engineering method for the measurement of sound pressure levels in rooms from service equipment installed in the building.
This document covers specifically measurements of sound from sanitary installations, mechanical ventilation, heating and cooling service equipment, lifts, rubbish chutes, heating devices, blowers, pumps and other auxiliary service equipment, and motor driven car park doors. It can also be applied to measurements of sounds from other types of equipment or activities within the building, e.g. noise from sport facilities or restaurants.
The measurement of noise from external sound sources generating air-borne or ground-borne noise in the building are not included in this document.
The methods are suitable for rooms with volumes of approximately 300 m3 or less for instance, in dwellings, hotels, schools, offices and hospitals.
The methods are not intended for measurements in large auditoria or concert halls.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies to nuclear power plants with water cooled reactors. This document does not apply to earthquakes stronger than the design basis earthquake. This document specifies guidance on the actions to be taken in preparation for and following an earthquake at a nuclear power plant. This document is intended to be used as a guideline for decision making regarding continued operation, shutdown and restart of the nuclear power plant after an earthquake. It can also be used to assist operating organizations in the preparation and implementation of an overall pre- and post-earthquake action programme for dealing with situations in accordance with the level of seismic ground motion experienced at the site, and the seismic design level of the plant.
- Standard12 pagesEnglish languagesale 15% off
This document specifies an engineering method for the measurement of sound pressure levels in rooms from service equipment installed in the building. This document covers specifically measurements of sound from sanitary installations, mechanical ventilation, heating and cooling service equipment, lifts, rubbish chutes, heating devices, blowers, pumps and other auxiliary service equipment, and motor driven car park doors. It can also be applied to measurements of sounds from other types of equipment or activities within the building, e.g. noise from sport facilities or restaurants. The measurement of noise from external sound sources generating air-borne or ground-borne noise in the building are not included in this document. The methods are suitable for rooms with volumes of approximately 300 m3 or less for instance, in dwellings, hotels, schools, offices and hospitals. The methods are not intended for measurements in large auditoria or concert halls.
- Standard20 pagesEnglish languagesale 15% off
- Standard22 pagesFrench languagesale 15% off
IEC 62561-7:2024 is available as IEC 62561-7:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62561-7:2024 specifies the requirements and tests for earthing enhancing compounds producing low resistance of an earth termination system. This third edition cancels and replaces the second edition published in 2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Figure A.1 has been replaced with a simpler one that clearly shows the high and low corrosion load limits of the earth enhancing compounds without the need for special knowledge;
b) pH measurement has been introduced.
- Standard58 pagesEnglish languagesale 15% off
- Standard37 pagesEnglish and French languagesale 15% off
This document applies to nuclear power plants with water cooled reactors and, in particular, to the design of components and civil structures against seismic events in order to meet the safety objectives. For other nuclear facilities the applicability of the document is checked in advance, before it might be applied correspondingly. Seismic isolation is not adressed in the series of ISO 4917. The following safety objectives are defined in order to ensure the protection of people and the environment against radiation risks: a) controlling reactivity; b) cooling fuel assemblies; c) confining radioactive substances; d) limiting radiation exposure.
- Standard17 pagesEnglish languagesale 15% off
This document applies to civil structures of nuclear power plants with water cooled reactors in order to achieve the safety objectives given in ISO 4917-1. For other nuclear facilities the applicability of the document needs to be checked in advance, before it might be applied correspondingly. This document specifies the requirements for civil structures for the verification of their load-bearing capacity in case of a seismic event. Additionally, requirements are specified pertaining to the verification of the serviceability of civil structures as far as necessary for maintaining their safety-related function in case of a seismic event (e.g. deformation and crack-width limitations). This document will be applied under the presumption that the geology and tectonics of the plant site have been investigated with special emphasis on the existence of active geological faults and lasting geological ground displacements, and that the site has been deemed suitable for a nuclear installation. To achieve these goals, this document deals with the requirements specific to the seismic design of civil structures above and beyond their conventional design. The basic requirements of these precautionary measures are dealt with in ISO 4917-1. This document does not apply to cranes, to detachment devices for lifting equipment nor to the supporting and mounting constructions of components. This document is independent of national standards. Recommendations, given in Annex A, are mainly based on the KTA Design-Philosophy and European standards. Alternatively other equivalent standards or regulations can be used in case the general requirements given in this document can be met. NOTE The term civil structures as used in this document comprise buildings and structural members made of reinforced concrete, pre-stressed concrete, steel, as well as steel composite structures and masonry. Among others, these include the containment, crane runways, platforms, fastening constructions and canals.
- Standard23 pagesEnglish languagesale 15% off
This document provides a procedure to validate a calculation tool based on simulation, analytical calculation and/or interpolation of airborne sound insulation characteristics of glass products.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies procedures for the calculation of the energy needs for heating and cooling,
internal temperatures and sensible and latent heat loads of a building according to the hourly
calculation methodology in ISO 52016-1. Additions or modifications of the calculations are provided
in this document if the building envelope contains one or more adaptive building envelope elements
(building envelope elements with adaptive components that are either environmentally or actively
controlled as a function of specific conditions). The adaptive building envelope element replaces the
transparent building element in the calculation according to ISO 52016-1.
The three types of adaptive building envelope elements covered in this document are:
— building envelope elements with dynamic solar shading;
— building envelope elements with chromogenic glazing;
— building envelope elements with an actively ventilated cavity.
Environmentally activated control is described for building envelope elements with chromogenic
glazing, but can also occur for other types of adaptive building envelope elements. In that case the same
approach applies as for environmentally activated chromogenic glazing.
This document is applicable to the assessment of the energy performance of buildings (EPB) (energy
performance labels and certificates), including comparison between buildings and checking conformity
with minimum energy performance criteria.
It is also applicable to assess the contribution of the adaptive building envelope element to the smart
readiness of a building.
In addition, this document provides indicators for the impact of the adaptive building envelope element
on the performance of the building compared to a reference building envelope element. It is applicable
to buildings at the design stage, to new buildings after construction and to existing buildings in the use
phase.
This document is not applicable to geometrically complex adaptive building envelope elements that can
only be modelled as multiple coupled thermal zones.
NOTE The background to the selection of adaptive building envelope elements is given in ISO/TR 52016-4.
- Standard66 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a test method for the determination of settlement of loose-fill insulation applied
horizontally in ventilated attics. This test method measures the effects of humidity and temperature
cycling.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 62561 specifies the requirements and tests for earth electrode inspection
housings (earth housings) installed in the earth and for earth electrode seals.
Lightning protection system components (LPSC) can also be suitable for use in hazardous
atmospheres. For this reason, there are additional requirements when installing the components
under such conditions.
NOTE Different requirements and test procedures are given in the EN 124 series [2] and the EN 1253 series [3].
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62561-5:2023 is available as IEC 62561-5:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62561-5:2023 specifies the requirements and tests for earth electrode inspection housings (earth housings) installed in the earth and for earth electrode seals. Lightning protection system components (LPSC) can also be suitable for use in hazardous atmospheres. For this reason, there are additional requirements when installing the components under such conditions. This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) A classification of earth electrode seals has been added.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This document describes a laboratory test method to determine the susceptibility of thermal insulation products used for construction against mould growth under specified climatic conditions.
The method is applicable to both factory-made products and in situ formed products. Factory-made products include panels, mats and rolls.
NOTE In situ formed products are usually those that are delivered loose and installed by blowing-in, pouring, or spraying-on, eventually using water and/or binder, whether or not they are also treated using additives.
The test is carried out with one of the conditions described in Table 1.
This test method determines the susceptibility of a thermal insulation material to mould growth, but it does not determine the suitability for use in a given design (wall, roof, etc.).
This method does not predict the resistance of an insulation product to water damage.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This document defines the acoustic performance of four classes (Classes A, B, C and D) of pipe insulation. It also defines a standardized test method for measuring the acoustic performance of any type of material system construction, thereby allowing existing and new insulation constructions to be rated against the four classes. Furthermore, this document presents some typical types of construction that would be expected to meet these acoustic performance classes. This document is applicable to the acoustic insulation of cylindrical steel pipes and to their piping components. It is valid for pipes up to 1 m in diameter and a minimum wall thickness of 4,2 mm for diameters below 300 mm, and 6,3 mm for diameters from 300 mm and above. It is not applicable to the acoustic insulation of rectangular ducting and vessels or machinery. This document covers both design and installation aspects of acoustic insulation and provides guidance to assist noise control engineers in determining the required class and extent of insulation needed for a particular application. It gives typical examples of construction methods, but the examples are for information only and not meant to be prescriptive. This document emphasises the aspects of acoustic insulation that are different from those of thermal insulation, serving to guide both the installer and the noise control engineer. Details of thermal insulation are beyond the scope of this document.
- Standard42 pagesEnglish languagesale 15% off
- Standard43 pagesFrench languagesale 15% off
This document specifies a test method for the determination of settlement of loose-fill insulation applied horizontally in ventilated attics. This test method measures the effects of humidity and temperature cycling.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62561-5:2023 is available as IEC 62561-5:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62561-5:2023 specifies the requirements and tests for earth electrode inspection housings (earth housings) installed in the earth and for earth electrode seals. Lightning protection system components (LPSC) can also be suitable for use in hazardous atmospheres. For this reason, there are additional requirements when installing the components under such conditions. This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) A classification of earth electrode seals has been added.
- Standard57 pagesEnglish languagesale 15% off
- Standard37 pagesEnglish and French languagesale 15% off
This document specifies a test method for the determination of settlement of loose-fill insulation applied horizontally in ventilated attics. This test method measures the effects of humidity and temperature cycling.
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
IEC 62561-4:2023 is available as which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 62561-4:2023 deals with the requirements and tests for metallic and non-metallic conductor fasteners that are used to retain and support the air-termination, down-conductor and earth-termination systems. This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with the latest edition of ISO IEC 60068-2-52:2017 relating to salt mist atmosphere treatment;
b) alignment with the new edition of ISO 22479:2019 relating to humid sulphurous atmosphere treatment;
c) new normative annex for the applicability of previous tests.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This document describes a method for measuring the insulation performance of building elements, e.g. exterior walls, floors, ceilings (hereinafter referred to collectively as "walls"). This is done by using the probe insertion method, which gives the temperature distribution in the wall with a temperature sensor in a small diameter borehole in the wall. The measurement method is divided into a quantitative method, which measures the thermal resistance with a heat flow measurement, and a qualitative method without heat flow measurement. This document describes a screening test that is used for preliminary and practical diagnosis. The method is applicable to plane building components with a light heat capacity, such as those in frame structure dwellings. The measured results give the insulation performance at the local measurement points rather than that of the whole panel including thermal bridges such as studs.
- Standard21 pagesEnglish languagesale 15% off
IEC 62561-4:2023 is available as IEC 62561-4:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62561-4:2023 deals with the requirements and tests for metallic and non-metallic conductor fasteners that are used to retain and support the air-termination, down-conductor and earth-termination systems. This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) alignment with the latest edition of ISO IEC 60068-2-52:2017 relating to salt mist atmosphere treatment; b) alignment with the new edition of ISO 22479:2019 relating to humid sulphurous atmosphere treatment; c) new normative annex for the applicability of previous tests.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies qualities for steels for seismic-proof improved structural use. It is applicable to steel plates rolled on a reversing mill, wide flats, hot-rolled sections, which are used in the as-rolled condition, with the exception of grade SA440, which is normally produced using quenched and tempered or thermomechanical controlled process and normally intended for welded or bolted structures. This document covers 5 steel grades and 7 qualities. Grades SA235, SA325, SA345, SA390 and SA440 are covered. Not all grades are available in all qualities, and some qualities have Charpy V‑notch requirements. The steels specified in this document are applicable to hot-rolled plates, wide flats, and sections with a minimum nominal thickness of 6 mm and a maximum nominal thickness of 150 mm for steel plates, and a maximum nominal thickness of 140 mm for wide flats and hot-rolled sections. This document does not include the following structural steels, some of which are covered by other International Standards: — sheet and strip, e.g. ISO 4995 or ISO 4996; — tubular products. e.g. ISO 12633-1, ISO 12633-2. NOTE The term "thickness" is considered as "nominal thickness", unless otherwise stated.
- Standard17 pagesEnglish languagesale 15% off
This document specifies a procedure to validate a calculation tool based on simulation, analytical calculation and/or interpolation of airborne sound insulation characteristics of glass products.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62561-4:2023 is available as IEC 62561-4:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62561-4:2023 deals with the requirements and tests for metallic and non-metallic conductor fasteners that are used to retain and support the air-termination, down-conductor and earth-termination systems. This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with the latest edition of ISO IEC 60068-2-52:2017 relating to salt mist atmosphere treatment;
b) alignment with the new edition of ISO 22479:2019 relating to humid sulphurous atmosphere treatment;
c) new normative annex for the applicability of previous tests.
- Standard73 pagesEnglish languagesale 15% off
- Standard46 pagesEnglish and French languagesale 15% off
This document specifies the model components to be used in a numerical hygrothermal simulation model for calculating the transient transfer of heat and moisture through building structures.
This document specifes a method to be used for validating a numeric hygrothermal simulation model claiming conformity with this ocument.
- Standard48 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies requirements and methodologies for infrared thermographic services for
detection of heat, air and moisture irregularities in buildings that help users to specify and understand
a) the extent of thermographic services required,
b) the type and condition of equipment available for use,
c) the qualifications of equipment operators, image analysts, and report authors and those making
recommendations, and
d) the reporting of results.
It provides guidance to understanding and utilizing the final results stemming from provision of the
thermographic services.
This document is applicable to the general procedures for infrared thermographic methods as can be
applied to residential, commercial, and institutional and special use buildings.
- Standard49 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies procedures for the calculation of the energy needs for heating and cooling, internal temperatures and sensible and latent heat loads of a building according to the hourly calculation methodology in ISO 52016-1. Additions or modifications of the calculations are provided in this document if the building envelope contains one or more adaptive building envelope elements (building envelope elements with adaptive components that are either environmentally or actively controlled as a function of specific conditions). The adaptive building envelope element replaces the transparent building element in the calculation according to ISO 52016-1.
The three types of adaptive building envelope elements covered in this document are:
— building envelope elements with dynamic solar shading;
— building envelope elements with chromogenic glazing;
— building envelope elements with an actively ventilated cavity.
Environmentally activated control is described for building envelope elements with chromogenic glazing, but can also occur for other types of adaptive building envelope elements. In that case the same approach applies as for environmentally activated chromogenic glazing.
This document is applicable to the assessment of the energy performance of buildings (EPB) (energy performance labels and certificates), including comparison between buildings and checking conformity with minimum energy performance criteria.
It is also applicable to assess the contribution of the adaptive building envelope element to the smart readiness of a building.
In addition, this document provides indicators for the impact of the adaptive building envelope element on the performance of the building compared to a reference building envelope element. It is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase.
This document is not applicable to geometrically complex adaptive building envelope elements that can only be modelled as multiple coupled thermal zones.
NOTE The background to the selection of adaptive building envelope elements is given in ISO/TR 52016-4.
- Standard66 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies procedures for the calculation of the energy needs for heating and cooling, internal temperatures and sensible and latent heat loads of a building according to the hourly calculation methodology in ISO 52016-1. Additions or modifications of the calculations are provided in this document if the building envelope contains one or more adaptive building envelope elements (building envelope elements with adaptive components that are either environmentally or actively controlled as a function of specific conditions). The adaptive building envelope element replaces the transparent building element in the calculation according to ISO 52016-1. The three types of adaptive building envelope elements covered in this document are: — building envelope elements with dynamic solar shading; — building envelope elements with chromogenic glazing; — building envelope elements with an actively ventilated cavity. Environmentally activated control is described for building envelope elements with chromogenic glazing, but can also occur for other types of adaptive building envelope elements. In that case the same approach applies as for environmentally activated chromogenic glazing. This document is applicable to the assessment of the energy performance of buildings (EPB) (energy performance labels and certificates), including comparison between buildings and checking conformity with minimum energy performance criteria. It is also applicable to assess the contribution of the adaptive building envelope element to the smart readiness of a building. In addition, this document provides indicators for the impact of the adaptive building envelope element on the performance of the building compared to a reference building envelope element. It is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase. This document is not applicable to geometrically complex adaptive building envelope elements that can only be modelled as multiple coupled thermal zones. NOTE The background to the selection of adaptive building envelope elements is given in ISO/TR 52016-4.
- Standard55 pagesEnglish languagesale 15% off
- Standard60 pagesFrench languagesale 15% off
IEC 62561-3:2023 © IEC 2023 – 7 –
LIGHTNING PROTECTION SYSTEM COMPONENTS (LPSC) –
Part 3: Requirements for isolating spark gaps (ISGs)
1 Scope
This part of IEC 62561 specifies the requirements and tests for isolating spark gaps (ISGs) for
lightning protection systems.
ISGs can be used to indirectly bond a lightning protection system to other nearby metalwork
where a direct bond is not permissible for functional reasons.
Typical applications include the connection to
• earth-termination systems of power installations,
• earth-termination systems of telecommunication systems,
• auxiliary earth electrodes of voltage-operated, earth fault circuit breakers,
• rail earth electrodes of power and DC railways,
• measuring earth electrodes for laboratories,
• installations with cathodic protection and stray current systems,
• service entry masts for low-voltage overhead cables,
• bypassing insulated flanges and insulated couplings of pipelines.
Applications where follow currents occur are not included.
Extra requirements for the components can be necessary for LSCs intended for use in
hazardous atmospheres.
NOTE 1 In CENELEC member countries, testing requirements of components for explosive atmospheres are
specified in CLC/TS 50703-2.
NOTE 2 Testing of components for an explosive atmosphere (as defined in the IEC 60079-10 series) is not covered
by this document.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 62561-3:2023 is available as IEC 62561-3:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62561-3:2023 specifies the requirements and tests for isolating spark gaps (ISGs) for lightning protection systems. ISGs can be used to indirectly bond a lightning protection system to other nearby metalwork where a direct bond is not permissible for functional reasons. This third edition cancels and replaces the second edition, published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. a) alignment with the latest edition of ISO 22479 relating to humid sulphurous atmosphere treatment; b) addition of a new normative Annex D for the applicability of previous tests.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard assigns sound insulation values to all transparent, translucent and opaque glass products, described in the European Standards for basic, special basic or processed glass products, when intended to be used in glazed assemblies in buildings, and which exhibit properties of acoustic protection, either as a prime intention or as a supplementary characteristic.
This document outlines the procedure, by which glass products may be rated, according to their acoustic performance which enables assessment of compliance with the acoustic requirements of buildings.
Rigorous technical analysis of measurement data remains an option, but this standard is intended to enable the derivation of simpler indices of performance, which can be adopted with confidence by non-specialists.
By adopting the principles of this standard the formulation of acoustic requirements in Building Codes and for product specification to satisfy particular needs for glazing is simplified.
It is recognised that the acoustic test procedures contained within EN ISO 140-1 and EN ISO 140-3 relate only to glass panes and their combinations. Although the same principles should be followed as closely as possible, it is inevitable that some compromises are necessary, because of the bulkier construction of other glazing types, e.g. glass blocks, paver units, channel-shaped glass, structural glazing and structural sealant glazing. Guidelines on how to adapt the test procedures for these glazing types are offered in Clause 4.
All the considerations of this standard relate to panes of glass/glazing alone. Incorporation of them into windows may cause changes in acoustic performance as a result of other influences, e.g. frame design, frame material, glazing material/method, mounting method, air tightness, etc. Measurements of the sound insulation of complete windows (glass and frame) may be undertaken to resolve such issues.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day