Abstract

IEC 60310:2026 specifies the terms and definitions, classification, service conditions, characteristics and test methods for transformers and inductors on board rolling stock. This document is applicable to traction and auxiliary power transformers installed on board rolling stock and to the various types of power inductors inserted in the traction and auxiliary circuits of rolling stock, of dry or liquid-immersed design. This document is also applicable to the traction transformers of three-phase AC line-side powered vehicles and to the transformers inserted in the single-phase or polyphase auxiliary circuits of vehicles, after agreement between purchaser and manufacturer. This document does not apply to instrument transformers, transformers of a rated output below 1 kVA single-phase or 5 kVA poly-phase, and inductors of a rated output below 1 kVAR single-phase or 5 kVAR poly-phase on board rolling stock. This document does not cover accessories such as tap changers, resistors, heat exchangers, fans, etc., intended for mounting on transformers or inductors, which are tested separately according to the relevant rules. This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) typical circuits for transformer and inductors are added;
b) letter symbols for cooling methods are added;
c) dielectric test table is modified;
d) subclauses for the tests of transformers and inductors are restructured;
e) temperature test for dry type transformer and dry type inductors are separated in different subclauses;
f) requirements for shock and vibration tests are updated according to IEC 61373:20.

Status
Published
Public Enquiry End Date
28-Feb-2025
Publication Date
01-Sep-2026
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
14-Jul-2026
Due Date
18-Sep-2026
Completion Date
02-Sep-2026

Buy Documents

Standard

SIST EN IEC 60310:2026

English language (81 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN IEC 60310:2026 is the CENELEC European Standard that adopts IEC 60310:2026 for railway applications - transformers and inductors on board rolling stock. It specifies the terms, classification, service conditions, characteristics and test methods for traction and auxiliary power transformers and for power inductors used in rolling stock.

It is aimed at purchasers, manufacturers, designers and test teams that need to specify, assess, type-test or routine-test these components for railway vehicles. The document also gives the information that has to be exchanged between the delivery parties so that the equipment can be matched to the vehicle duty and operating environment.

What does SIST EN IEC 60310:2026 specify?

SIST EN IEC 60310:2026 covers transformers and inductors installed on board rolling stock, including dry-type and liquid-immersed designs. It also applies to traction transformers for three-phase AC line-side powered vehicles and to transformers in single-phase or polyphase auxiliary circuits when purchaser and manufacturer agree.

The scope excludes instrument transformers, small transformers below the stated rated outputs, and inductors below the stated rated outputs. Accessories such as tap changers, resistors, heat exchangers and fans are treated separately and are tested according to the relevant rules.

The document is organized in clauses 1 to 14 and Annexes A to F. Clauses 3 to 14 move from definitions and classification to ratings, cooling, temperature limits, mechanical design, fire protection, marking and testing.

AnnexWhat it covers
Annex AItems that need agreement between purchaser and manufacturer, plus the information each party provides
Annex BThermal endurance, ageing, thermal design considerations and end-of-life criterion
Annex CWorked example of thermal endurance calculation
Annex DWet dielectric tests for dry-type wound components
Annex ELoad profiles
Annex FBackground to reference temperature and dielectric test voltage

What are the key requirements of SIST EN IEC 60310:2026?

Application, ratings and operating data

Clause 5 links normal service conditions to IEC 62498-1 and pollution degree to IEC 62497-1. In practice, the purchaser has to state the railway environment clearly, because special service conditions are only valid when both parties agree.

Clause 6 makes the load profile a core part of the specification. SIST EN IEC 60310:2026 says the purchaser should provide the load profile, including the current frequency spectrum, because the winding current, heating and ageing depend on how the equipment is actually used on the train.

Clause 7 defines rated line-side voltage, rated secondary voltage and rated power of transformer windings. Clause 8 requires tappings to be identified, including the principal tapping, so that the transformer can be matched to the traction voltage and to the motor voltage in service.

Cooling and temperature limits

Clause 9 requires transformers and inductors to be identified by cooling method using the document’s letter symbols. That matters because the cooling arrangement affects temperature rise, permissible load and the way a unit is marked and specified.

Clause 10 sets temperature limits for solid insulation, liquid and other parts. The limits depend on the thermal class of the insulating materials and on whether the design is dry-type or immersed, so designers and buyers need to align the insulation system with the intended duty and ambient conditions.

Annex B and Annex C support thermal design by linking temperature, thermal endurance and expected life. In practice, these annexes help the manufacturer justify that the insulation system suits the load profile and the purchaser’s required service life.

Mechanical design, fire protection and marking

Clause 11 allows the mechanical behaviour to be proven either by finite element analysis (FEA) or by shock and vibration testing. If FEA is used, it has to cover static load cases, modal behaviour up to 60 Hz and fatigue assessment based on IEC 61373 test conditions, so the result is not just a shape check but a durability justification.

Clause 12 requires non-metalized materials outside the enclosure to follow a fire protection standard agreed by the manufacturer and purchaser. That makes fire performance part of procurement rather than an afterthought.

Clause 13 requires a visible, weatherproof rating plate with indelible markings. The plate has to carry the identifying and rating data needed for installation, maintenance, traceability and inspection.

Tests and acceptance

Clause 14 classifies tests as type tests, routine tests and investigation tests, and Table 5 links each check or test to the relevant equipment and test category. This is the main production and qualification framework, so it tells the reader which tests belong to design approval and which belong to routine factory control.

The test programme includes visual checks, functional tests, winding resistance, voltage ratio and polarity, impedance or inductance, no-load current and losses, load losses, temperature-rise, insulation resistance, dielectric tests, partial discharge, short-circuit withstand, shock and vibration, VTR, noise, leakage magnetic flux density, FRA and inrush current. For dry-type equipment, Annex D adds wet dielectric tests where required by the application.

What terms does SIST EN IEC 60310:2026 define?

  • Traction transformer - A transformer that supplies the traction circuits, and may also supply other equipment.
  • Auxiliary transformer - A transformer that supplies electrical equipment other than the traction circuits.
  • Inductor - The term used in this document with the same meaning as reactor.
  • Principal tapping - The tapping that gives the rated traction motor voltage when the transformer is fed at rated voltage and frequency.
  • Rated current - The current a winding can sustain permanently at the reference temperature for continuous load.
  • Electrical insulating material (EIM) - The insulating material whose thermal endurance is assessed for a specified property and end-point.
  • Electrical insulating system (EIS) - The insulation system made up of materials working together in the transformer or inductor.
  • Consumed Endurance Potential (CEP) - The thermal-endurance measure used in Annex B to judge whether the insulation system remains acceptable across service conditions.

Who uses SIST EN IEC 60310:2026?

This standard is used by railway equipment manufacturers who design traction transformers, auxiliary transformers and inductors for rolling stock. It is also used by rolling stock builders, system integrators and purchasers when they define duty, cooling, ratings, temperature limits and acceptance tests.

Test laboratories use it for routine, type and investigation testing, especially for dielectric tests, temperature-rise tests, shock and vibration tests, partial discharge and acoustic measurements. Quality managers and approval teams use it to check whether a delivered unit matches the agreed specification and the required marking, documentation and test evidence.

What changed in SIST EN IEC 60310:2026 from the previous edition?

SIST EN IEC 60310:2026 is the fifth edition and it replaces EN 60310:2016 and its amendments and corrigenda. The text is described as a technical revision.

The stated changes are:

  • typical circuits for transformers and inductors are added
  • letter symbols for cooling methods are added
  • the dielectric test table is modified
  • the subclauses for transformer and inductor tests are restructured
  • the temperature test for dry-type transformers and dry-type inductors is split into separate subclauses
  • the shock and vibration test requirements are updated according to IEC 61373:20-

Which standards are used with SIST EN IEC 60310:2026?

SIST EN IEC 60310:2026 builds on IEC 60076-1 for general transformer terminology, IEC 60076-2 for temperature rise, IEC 60076-3 for insulation levels and dielectric tests, IEC 60076-5 for short-circuit strength, IEC 60076-6 for reactors, IEC 60076-10 for sound levels, IEC 60076-12 for dry-type loading and IEC 60076-18 for frequency response measurement.

It also refers to IEC 60296, IEC 60836, IEC 61039 and IEC 61099 for insulating liquids, IEC 60850 for traction system supply voltages, IEC 61373 for shock and vibration, IEC 61378-1 for converter transformers, IEC 62497-1 for insulation coordination and IEC 62498-1 for rolling stock environmental conditions. ISO 3746, ISO 9614-1 and ISO 9614-2 provide the noise measurement methods used for sound power assessment.

For thermal and insulation-system background, the document refers to IEC 60085, IEC 60216-1, IEC 60216-5 and IEC 60505. For dielectric-test background and test practice, it also refers to IEC 60060-1, IEC 60060-2 and IEC 60076-14.

What does the SIST EN IEC 60310:2026 document contain?

The document contains typical circuit diagrams for traction and auxiliary transformer arrangements, plus tables for cooling symbols, temperature limits, test lists, tolerances, reference temperatures, dielectric test voltages and partial discharge criteria. It also includes figures for induced-voltage and separate-source test setups, impulse connections, partial discharge behavior, VTR configurations and a test circuit.

Annex B and Annex C provide the thermal endurance framework and a worked calculation example, which are useful for specification review and design justification. Annex D gives step-by-step wet dielectric procedures for dry-type wound components, including soaking, misting and thermal-shock-related checks.

Annex E describes load profiles in terms of normal load, overload, transient surge, seasonal operation and cooling-related conditions. Annex F explains the background to the reference temperature and the dielectric test voltage values used in this standard, which helps users understand why the test levels are set as they are.

Relations

Effective Date
26-May-2026
Effective Date
26-May-2026
Effective Date
26-May-2026
Effective Date
26-May-2026
Effective Date
26-May-2026
Effective Date
26-May-2026
Effective Date
26-May-2026
Effective Date
26-May-2026
Effective Date
26-May-2026
Effective Date
26-May-2026
Effective Date
26-May-2026
Effective Date
26-May-2026
Effective Date
26-May-2026
Effective Date
26-May-2026
Effective Date
26-May-2026

Buy Documents

Standard

SIST EN IEC 60310:2026

English language (81 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

IRIS Certification (UNIFE)

International Railway Industry Standard certification.

BELAC Belgium Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

Sponsored listings

Frequently Asked Questions

SIST EN IEC 60310:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Railway applications - Traction transformers and inductors on board rolling stock". This standard covers: IEC 60310:2026 specifies the terms and definitions, classification, service conditions, characteristics and test methods for transformers and inductors on board rolling stock. This document is applicable to traction and auxiliary power transformers installed on board rolling stock and to the various types of power inductors inserted in the traction and auxiliary circuits of rolling stock, of dry or liquid-immersed design. This document is also applicable to the traction transformers of three-phase AC line-side powered vehicles and to the transformers inserted in the single-phase or polyphase auxiliary circuits of vehicles, after agreement between purchaser and manufacturer. This document does not apply to instrument transformers, transformers of a rated output below 1 kVA single-phase or 5 kVA poly-phase, and inductors of a rated output below 1 kVAR single-phase or 5 kVAR poly-phase on board rolling stock. This document does not cover accessories such as tap changers, resistors, heat exchangers, fans, etc., intended for mounting on transformers or inductors, which are tested separately according to the relevant rules. This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) typical circuits for transformer and inductors are added; b) letter symbols for cooling methods are added; c) dielectric test table is modified; d) subclauses for the tests of transformers and inductors are restructured; e) temperature test for dry type transformer and dry type inductors are separated in different subclauses; f) requirements for shock and vibration tests are updated according to IEC 61373:20.

IEC 60310:2026 specifies the terms and definitions, classification, service conditions, characteristics and test methods for transformers and inductors on board rolling stock. This document is applicable to traction and auxiliary power transformers installed on board rolling stock and to the various types of power inductors inserted in the traction and auxiliary circuits of rolling stock, of dry or liquid-immersed design. This document is also applicable to the traction transformers of three-phase AC line-side powered vehicles and to the transformers inserted in the single-phase or polyphase auxiliary circuits of vehicles, after agreement between purchaser and manufacturer. This document does not apply to instrument transformers, transformers of a rated output below 1 kVA single-phase or 5 kVA poly-phase, and inductors of a rated output below 1 kVAR single-phase or 5 kVAR poly-phase on board rolling stock. This document does not cover accessories such as tap changers, resistors, heat exchangers, fans, etc., intended for mounting on transformers or inductors, which are tested separately according to the relevant rules. This fifth edition cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) typical circuits for transformer and inductors are added; b) letter symbols for cooling methods are added; c) dielectric test table is modified; d) subclauses for the tests of transformers and inductors are restructured; e) temperature test for dry type transformer and dry type inductors are separated in different subclauses; f) requirements for shock and vibration tests are updated according to IEC 61373:20.

SIST EN IEC 60310:2026 is classified under the following ICS (International Classification for Standards) categories: 29.180 - Transformers. Reactors; 45.060.01 - Railway rolling stock in general; 45.060.10 - Tractive stock. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN IEC 60310:2026 has the following relationships with other standards: It is inter standard links to SIST EN 60076-3:2014, SIST EN IEC 61039:2025, SIST EN 60076-18:2012, SIST EN ISO 9614-1:2009, SIST EN 60076-1:2012, SIST EN 61099:2011, SIST EN IEC 60296:2020, SIST EN 60076-10:2017, SIST EN ISO 9614-2:1997, SIST EN 60836:2015, SIST EN ISO 3746:2011, SIST EN 60076-5:2006, SIST EN 60076-6:2008, SIST EN 61378-1:2012, SIST EN 60076-2:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN IEC 60310:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms, definitions and abbreviated terms
  • 3.1 Terms and definitions
  • 3.1.1.1 traction transformer
  • 3.1.1.2 auxiliary transformer
  • 3.1.1.3 inductor
  • 3.1.1.4 load profile
  • 3.1.1.5 short time emergency loading
  • 3.1.1.6 cooling medium
  • 3.1.1.7 rated insulation voltage
  • 3.1.1.8 nominal voltage
  • 3.1.1.9 rated voltage
  • 3.1.1.10 rated impulse voltage
  • 3.1.1.11 test voltage
  • 3.1.1.12 recurring peak voltage
  • 3.1.2.1 voltage transmission ratio
  • 3.1.2.2 impedance voltage
  • 3.1.2.3 tolerance
  • 3.1.3.1 AC inductance
  • 3.1.3.2 differential inductance
  • 3.1.3.3 incremental inductance
  • 3.1.4.1 thermal endurance
  • 3.1.4.2 temperature index
  • 3.1.4.3 halving interval
  • 3.1.5.1 thermal endurance in continuous operation
  • 3.1.5.2 actual operating time
  • 3.1.5.3 consumed endurance potential
  • 3.2 Abbreviated terms
  • 4 Classification
  • 4.1 General
  • 4.2 Classification of transformers
  • 4.3 Classification of inductors
  • 5 Service conditions
  • 6 Rated current and load profile
  • 6.1 Load profile
  • 6.2 Rated current
  • 7 Rated voltage and power of transformer windings
  • 7.1 Rated line-side voltage
  • 7.2 Rated secondary voltage
  • 7.3 Rated power of transformer
  • 8 Transformer tappings
  • 9 Cooling
  • 9.1 Identification of transformers and inductors according to cooling method
  • 9.2 Arrangement of symbols
  • 10 Temperature limits
  • 10.1 Classification of insulating materials
  • 10.2 Temperature limits of solid insulation
  • 10.3 Temperature limits for liquid
  • 10.4 Temperature limits for other parts
  • 11 Mechanical design
  • 12 Fire protection
  • 13 Rating plates
  • 13.1 General
  • 13.2 Rating plates for transformer
  • 13.3 Rating plates for inductor
  • 14 Tests
  • 14.1 Categories of tests
  • 14.2 List of checks and tests
  • 14.3 Tolerances
  • 1. Winding resistance 14.4.4.1 +10 %
  • 3. Voltage ratio at no-load on 14.4.5 ±0,5 % of the ratio declared
  • 4. Impedance voltage for ±10 % of the declared
  • 14.4.6 principal tapping impedance voltage for that
  • 5. No-load current 14.4.8 +30 % of the declared no-load
  • 1. Winding resistance 14.4.4.2 +10 %
  • 2. Losses 14.4.10.2 +10 % of the total losses
  • 3. Inductance 14.4.7 ±10 % of the declared
  • 14.4 Test items
  • 2 K per hour in the windings and the magnetic core(s). The winding temperatures shall then
  • 5 X X
  • Annex A
  • 14.2 Tests as separate equipment for differential inductors associated with
  • 7.1 Rated line-side voltage other than the nominal voltage of the traction
  • Annex B
  • Annex C
  • Annex D
  • Annex E
  • Annex F
  • Bibliography

1 Scope

This document specifies the terms and definitions, classification, service conditions, characteristics and test methods for transformers and inductors on board rolling stock. This document is applicable to traction and auxiliary power transformers installed on board rolling stock and to the various types of power inductors inserted in the traction and auxiliary circuits of rolling stock, of dry or liquid-immersed design.

This document is also applicable to the traction transformers of three-phase AC line-side powered vehicles and to the transformers inserted in the single-phase or polyphase auxiliary circuits of vehicles, after agreement between purchaser and manufacturer. This document does not apply to instrument transformers, transformers of a rated output below 1 kVA single-phase or 5 kVA poly-phase, and inductors of a rated output below 1 kVAR singlephase or 5 kVAR poly-phase on board rolling stock. This document does not cover accessories such as tap changers, resistors, heat exchangers, fans, etc., intended for mounting on transformers or inductors, which are tested separately according to the relevant rules.

NOTE Items requiring agreement between the delivery parties and items of supplementary information and specification particulars to be provided by the ordering party or manufacturer are given in Annex A.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

IEC 60076-1:2011, Power transformers - Part 1: General IEC 60076-2, Power transformers - Part 2: Temperature rise for liquid-immersed transformers IEC 60076-3, Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air IEC 60076-5, Power transformers - Part 5: Ability to withstand short circuit IEC 60076-6:2007, Power transformers - Part 6: Reactors IEC 60076-10, Power transformers - Part 10: Determination of sound levels IEC 60076-12:2008, Power transformers - Part 12: Loading guide for dry-type transformers IEC 60076-18, Power transformers - Part 18: Measurement of frequency response IEC 60296, Fluids for electrotechnical applications - Mineral insulating oils for electrical equipment IEC 60836, Specifications for unused silicone insulating liquids for electrotechnical purposes IEC 60850, Railway applications - Supply voltages of traction systems

SIST EN IEC 60310:2026

IEC 61039, Classification of insulating liquids IEC 61099, Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes

IEC 61373:20—, Railway applications - Rolling stock equipment - Shock and vibration tests IEC 61378-1:2011, Converter transformers - Part 1: Transformers for industrial applications IEC 62497-1:2010, Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment IEC 62497-1:2010/AMD1:2013 IEC 62498-1, Railway applications - Environmental conditions for equipment - Part 1:

Equipment on board rolling stock ISO 3746, Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane ISO 9614-1, Acoustics - Determination of sound power levels of noise sources using sound intensity - Part 1: Measurement at discrete points ISO 9614-2, Acoustics - Determination of sound power levels of noise sources using sound intensity - Part 2: Measurement by scanning

3 Terms, definitions and abbreviated terms

For the purposes of this document, the terms and definitions given in IEC 60076-1, IEC 62497-1 and the following apply.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

- IEC Electropedia: available at https://www.electropedia.org/ - ISO Online browsing platform: available at https://www.iso.org/obp NOTE 1 When the term "transformer" is used alone, it applies to both traction and auxiliary transformers. NOTE 2 The term "transformer(s)/inductor(s)" appears in clauses applicable to both transformers and inductors to avoid duplication of text.

NOTE 3 The term "inductor" is used in this document with the same meaning as the term "reactor" mentioned in IEC 60050-421, IEC 60050-811 and IEC 60076-6.

Under preparation. Stage at the time of publication: IEC FDIS 61373:2024.

SIST EN IEC 60310:2026

3.1 Terms and definitions

3.1.1 General definitions

3.1.1.1 traction transformer

transformer intended to supply the traction circuits, and optionally other equipment

3.1.1.2 auxiliary transformer

<on-board power supply system> transformer intended to supply electrical equipment except traction circuits Note 1 to entry: In the energy storage system, the transformer that supplies power to the traction circuit(s) is called a traction transformer, and that supplying power to the electrical equipment except traction circuit(s) is called an auxiliary transformer.

3.1.1.3 inductor

two-terminal device characterized essentially by its inductance [SOURCE: IEC 60050-151:2001, 151-13-25, modified – The notes to entry have been omitted.]

3.1.1.4 load profile

<component> component output power or current versus time under specified conditions including voltage, rectifier, configuration, harmonic content, etc. Note 1 to entry: Efficiency for the transformer is agreed between the manufacturer and purchaser.

3.1.1.5 short time emergency loading

unusually heavy loading of a transient nature (less than one time constant of the transformer) occurring during degraded mode, such as a loss of one traction converter, etc. [SOURCE: IEC 60076-12:2008, 3.2, modified – ”(less than one time constant of the coil)” replaced with “(less than one time constant of the transformer)”, “ the occurrence of one or more unlikely events which seriously disturb normal system loading” replaced with “occurring during degraded mode”]

3.1.1.6 cooling medium

medium used to extract the heat out of the transformer or inductor e.g. air, water, oil, heat sink, etc.

SIST EN IEC 60310:2026

3.1.1.7 rated insulation voltage

U Nm RMS withstand voltage value assigned by the manufacturer to the equipment or a part of it, characterising the specified permanent (over 5 min) withstand capability of its insulation Note 1 to entry: U is a voltage between a live part of equipment and earth or another live part. For rolling stock, Nm earth refers to the car body.

Note 2 to entry: For circuits, systems and sub-systems in railway applications, this definition is preferred to "highest voltage for equipment" which is widely used in international standards. Note 3 to entry: U is higher than or equal to the working voltage. As a consequence, for circuits directly connected Nm to the contact line, U is equal to or higher than U as specified in IEC 60850. For circuits connected to electronic Nm max1 converter U is higher than or equal to the DC link voltage.

Nm Note 4 to entry: U is not necessarily equal to the rated voltage which is primarily related to functional Nm performance.

[SOURCE: IEC 62497-1:2010, 3.4.4, modified – Addition of the second sentence in Note 3 to etnry.]

3.1.1.8 nominal voltage

U n suitable approximate voltage used to designate or identify a given supply system

3.1.1.9 rated voltage

U r value of voltage assigned for a specific operating condition

3.1.1.10 rated impulse voltage

U Ni impulse voltage value, characterizing the specified withstand capability of its insulation against transient over-voltages

3.1.1.11 test voltage

U a RMS value derived from U used for separate source voltage, induced voltage, voltage Nm between terminals withstand, depending on test carried out

3.1.1.12 recurring peak voltage

U mT U mG maximum peak value of periodic excursions of the voltage waveform between terminals (U ) mT

or between terminals and ground (U mG

SIST EN IEC 60310:2026

3.1.2 Definitions for transformers

3.1.2.1 voltage transmission ratio

VTR ratio between the secondary voltage and the primary voltage when a specified impulse or AC square voltage is applied on the primary Note 1 to entry: The VTR is expressed as a percentage of this applied voltage.

3.1.2.2 impedance voltage

voltage applied to reach the rated current in short-circuit Note 1 to entry: This is expressed as a percentage of this applied voltage to the rated voltage at reference temperature.

Note 2 to entry: When expressed as a percentage or per unit, this is equal to the short circuit impedance referred in IEC 60076-1:2011, 3.7.1.

3.1.2.3 tolerance

permitted deviation between the declared value of a quantity and the measured value [SOURCE: IEC 60050-411:2007, 411-36-19]

3.1.3 Definitions for inductors

NOTE Values of inductance for inductors are related to the different classes of utilization and are defined as follows, with the understanding that they include an indication of the nature and value of the current used in their measurement.

3.1.3.1 AC inductance

inductance derived from the measurement of the alternating current carried by the inductor when it is supplied by a sinusoidal alternating voltage of specified value and frequency [SOURCE: IEC 60050-811:2017, 811-26-36]

3.1.3.2 differential inductance

inductance defined from the derivative of the linked flux as a function of current (equal to the slope of the magnetic characteristic) Note 1 to entry: It is derived from the transient record of instantaneous voltage and current in the inductor or from the measurement of the variation of magnetic flux.

3.1.3.3 incremental inductance

inductance seen by the AC current of a particular value and frequency superimposed on a DC current through the inductor Note 1 to entry: The ripple factor of a pulsating current, expressed as a percentage, is conventionally defined by the formula:

II− max min ×100 II+ max min where I and I respectively represent the maximum and minimum values of the current wave. max min Note 2 to entry: It is derived from a record of the terminal voltage.

SIST EN IEC 60310:2026

3.1.4 Definitions of thermal endurance

3.1.4.1 thermal endurance

time taken for the deterioration of a selected property (electrical, mechanical, etc.) to reach a specified end-point at a given temperature Note 1 to entry: An insulation material mainly ensures the electric performance (dielectric strength) of the conductor insulation, while the impregnation, casting, sealing, coating, etc., materials mainly ensure the mechanical performance of the windings (water tightness, resistance to thermal cycling and shock, resistance to vibration or shocks, thermal conduction, etc.).

Note 2 to entry: An end-point of 50 % of the initial value of the property is used (unless otherwise specified).

3.1.4.2 temperature index

TI numerical value of the temperature (in degrees Celsius) derived from the thermal endurance relationship at a time of 20 000 h (unless otherwise specified) Note 1 to entry: TI is referring to the RTE (Relative Thermal Endurance) or ATE (Assessed Thermal Endurance) indexes used in IEC 60216-5.

3.1.4.3 halving interval

HIC numerical value of the temperature interval (in Kelvins) which expresses the halving of the time to end-point taken at the temperature equal to TI [SOURCE: IEC 60050-212:2010, 212-12-13, modified – "corresponding to the temperature index or the relative temperature index" has been replaced with "equal to TI".]

3.1.5 Definitions of thermal endurance calculations

NOTE As far as thermal endurance calculations are concerned, IEC 60076-12 provides an explanation of ageing fundamentals and the means to estimate ageing rate and consumption of lifetime of the transformer or inductor insulation as a function of operating temperature, time and loading. The hot-spot temperature is used to estimate the number of hours of lifetime consumed during a particular time period of loading.

3.1.5.1 thermal endurance in continuous operation

ECO value derived from the simplified equation of the Arrhenius plot (based on TI and HIC) for a given hotspot temperature θ (°C) HS TI−θ HS HIC

ECO(h) 20 000× 2 Note 1 to entry: This simplified formula is very convenient to understand the concept of TI and HIC. However, this formula yields slightly pessimistic results compared to the exact formula. Note 2 to entry: Whenever possible, the exact Arrhenius formula derived from the endurance graph (constants A and B) is used, where E(h) is the thermal endurance and T (K) = θ (°C) + 273,15 is the thermodynamic (absolute) HS HS hot-spot temperature:

B logEh( ) logA+ TK() HS which represents the thermal endurance graph, or

b Eh( ) a× exp

T HS

which expresses directly the thermal endurance value.

SIST EN IEC 60310:2026

3.1.5.2 actual operating time

AOT actual time (in hours) the insulating system will operate at the given hotspot temperature

3.1.5.3 consumed endurance potential

CEP ratio of actual operating time by consumed endurance potential for a given hotspot temperature AOT

CEP % × 100

ECO

3.2 Abbreviated terms

For the purposes of this document, the following abbreviations apply:

AC alternating current AOT actual operating time ATE assessed thermal endurance CEP consumed endurance potential DC direct current ECO thermal endurance in continuous operation EIM electrical insulating material EIS electrical insulating system FEA finite element analysis FRA frequency response analysis HIC halving interval HV high voltage RMS root mean square RTE relative thermal endurance TI thermal index VTR voltage transmission ratio

4 Classification

4.1 General

The traction transformer and auxiliary transformer could be integrated, i.e. the traction transformers could have several secondary windings, such as traction windings, auxiliary windings. Traction windings supply power to traction circuits. Auxiliary windings supply power to auxiliary equipment.

NOTE In this document, the load side windings that feed the traction circuit or the auxiliary circuit used for other purposes or both are collectively called "secondary windings". The typical circuits are described in this document to show the functions of each component. Figure 1 shows the typical circuit diagram for traction transformer with auxiliary windings, and Figure 2 shows that of separated traction and auxiliary transformers, while the traction transformer is fed by AC power supply system, and the auxiliary transformer is fed by an inverter connected to DC intermediate link. Figure 3 shows the typical circuit diagram for auxiliary transformer fed by DC power supply system. Figure 4 shows the typical circuit diagram for traction transformer (Medium Frequency Transformer) fed by Energy Storage System such as fuel cell battery system.

SIST EN IEC 60310:2026

Figure 1 – Traction transformer with auxiliary windings fed by AC power supply system

Figure 2 – Traction transformer without auxiliary windings fed by AC power supply system

SIST EN IEC 60310:2026

Figure 3 – DC locomotive typical circuit diagram

Figure 4 – Energy storage system typical circuit diagram

4.2 Classification of transformers

The transformers mentioned above can be:

  • traction transformers to supply the traction circuits, and optionally also other equipment;
  • auxiliary transformers to supply electrical equipment except traction circuits. Windings mentioned in this document can be:
  • line side windings which are directly connected to the power supply line;
  • traction windings which supply the traction circuits;
  • auxiliary windings which are used for other purposes.

SIST EN IEC 60310:2026

4.3 Classification of inductors

According to their use, inductors can be classified as follows:

  • inductors for AC:

inductors that carry alternating current, such as transition inductors used for transition between tappings of tap changers, inductors for AC commutator motor braking circuits, interference suppression inductors, tuned filter inductors, etc.; - inductors for DC:

inductors that carry DC with small or negligible AC components, such as DC line filter inductors, inductive shunts for traction motors, inductors for DC motor braking circuits, etc.; - inductors for pulsating current:

inductors that carry DC or AC current with a significant periodic ripple, such as smoothing inductors for traction motors, sinusoidal filter inductors in auxiliary converters, etc.

5 Service conditions

The normal service conditions for transformers and inductors shall be in accordance with IEC 62498-1. The pollution degree shall be specified in accordance with IEC 62497-1. Special service conditions shall be agreed between the purchaser and manufacturer.

6 Rated current and load profile

6.1 Load profile

A transformer or inductor is designed to operate on the train in steady-state and transient (surge) conditions, both in normal and overload conditions.

The purchaser should specify the load profile according to Annex E (informative). The current frequency spectrum shall be specified by the responsible party.

6.2 Rated current

The rated current of a winding is the current this winding can sustain permanently at the reference temperature for continuous load.

The rated current shall be calculated according to following methods:

a) RMS current derived from the load profiles; b) directly specified by the purchaser.

NOTE 1 For thermal ageing of insulating materials, see Annex B. Special attention should be paid to varying cooling modes and to the averaging time window. The reference temperature for continuous load is the cooling medium temperature at the external interface of the transformer or inductor. It shall be:

c) directly specified by the purchaser; Specified values should be based on the air temperature external to vehicle as defined in IEC 62498-1.

NOTE 2 It can also be calculated by the manufacturer based on the temperature histogram provided by the purchaser and the method of Annex B: see cooling medium reference temperature for lifetime calculation in B.2.2.

SIST EN IEC 60310:2026

For a traction winding, the rated current shall correspond to the principal tapping. This definition of rated current applies when other windings, which are normally on load, deliver their rated loads.

7 Rated voltage and power of transformer windings

7.1 Rated line-side voltage

The rated line-side voltage is the RMS voltage applicable in normal operating conditions to the line-side winding group. If this winding has tappings, the rated voltage shall be referred to the principal tapping.

Unless otherwise agreed between purchaser and manufacturer, the rated line-side voltage is specified as being equal to the nominal voltage of the traction system. NOTE IEC 60850 gives the list of the nominal voltages of traction systems.

7.2 Rated secondary voltage

The rated voltage of a secondary winding of a transformer is the RMS no-load voltage at the terminals of the winding when the principal tapping of the line-side winding of the transformer is fed at its rated voltage and frequency.

7.3 Rated power of transformer

The rated power of a transformer winding is defined as the product of the rated voltage of this winding and its rated current.

NOTE Transformers usually have several secondary windings (e.g. traction, auxiliaries, train heating). The rated power of the line-side winding of a transformer can be less than the sum of the rated powers of its various secondary windings.

...