SIST ETS 300 342-2:1999
(Main)Radio Equipment and Systems (RES); ElectroMagnetic Compatibility (EMC) for European digital cellular telecommunications system (GSM 900 MHz and DCS 1 800 MHz); Part 2: Base station radio and ancillary equipment
- Abstract
Covers the EMC requirements for GSM 900 MHz & DCS 1800 MHz equipment. The ETS may be used to demonstrate compliance with the requirements of the EMC Directive 89/336/EEC.
- Status
- Published
- Publication Date
- 30-Jun-1999
- Technical Committee
- RES - Radio equipment and systems
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Jul-1999
- Due Date
- 01-Jul-1999
- Completion Date
- 01-Jul-1999
SIST ETS 300 342-2:1999 is the Slovenian standard identical to ETS 300 342-2 Edition 1 from ETSI. It specifies EMC test methods, limits and minimum performance criteria for GSM 900 MHz and DCS 1800 MHz base station radio equipment and the associated ancillary equipment. It is intended for assessing compliance with the EMC Directive 89/336/EEC.
What does SIST ETS 300 342-2:1999 specify?
SIST ETS 300 342-2:1999 covers the EMC assessment of radio communications equipment used as GSM 900 MHz and DCS 1800 MHz digital public cellular base stations. It defines the applicable tests, the measurement methods, the limits and the minimum performance criteria for speech and/or data equipment and related ancillary equipment.
The scope places Base Transceiver Stations (BTSs) and single cabinet Base Station Systems (BSSs) in the main equipment category. Base Station Controllers (BSCs) and Transcoders (XC) may be treated as ancillary equipment by the manufacturer. Mobile services Switching Centres (MSCs) and Echo Cancellers (ECs) are outside the coverage.
The document is organized into clauses 1 to 9. It moves from scope and normative references to definitions, general test conditions, performance assessment, performance criteria, an applicability overview, emission tests, and immunity tests. Clause 7 gives the overview of which tests apply to which ports and equipment types.
What are the key requirements of SIST ETS 300 342-2:1999?
Clause 4 sets the test conditions. Equipment is tested under normal declared temperature, humidity and supply voltage, with the configuration kept close to intended use. For immunity testing, transmitters operate at maximum rated output power up to 20 W, receivers use a wanted input signal, and duplex transceivers are exercised as both. In practice, the test report has to show how the equipment was set up and why that setup represents normal use.
Clause 4.3 to 4.10 define how the communication link is established and monitored. The standard uses a suitable mobile or mobile simulator, selected channel numbers and the monitoring of RXQUAL. It also defines exclusion bands for transmitters and receivers and a method for identifying narrow band responses. This matters because the test only counts disturbances that represent real EMC problems, not normal tuned responses.
Clause 5 requires the manufacturer to declare the functions and equipment used for assessment. The manufacturer provides the intended functions, user controls, stored data, port list and the ancillary equipment used during testing. For fixed remote ancillary equipment, all applicable emission and immunity clauses apply. This is important because the pass/fail decision depends on what functions must survive the EMC stress.
Clause 6 defines performance criteria CT, TT, CR and TR. Continuous phenomena require the communication link to remain established, and for base stations the RXQUAL limit is part of the acceptance check. Transient phenomena allow only limited disturbance at each exposure, and the equipment must still operate as intended at the end of the full sequence. For transmitter-only equipment, the test also checks that unwanted transmission does not occur in standby.
Clauses 8 and 9 split the compliance work into emission and immunity testing. Emission tests cover enclosure radiation, dc power ports, ac mains ports, antenna ports on base stations, and the associated limits and measurement methods. Immunity tests cover RF fields, electrostatic discharge, fast transients, RF common mode, voltage dips and interruptions, surges, and RF conducted immunity at the antenna port. For a test lab, this tells you which ports need measurement and which environmental disturbances must be applied.
Clause 7 ties the whole document together. The applicability tables show which tests apply to base station equipment, fixed ancillary equipment, and which reference standards are used for each test. That makes the standard usable as a test plan, not just a list of limits.
What terms does SIST ETS 300 342-2:1999 define?
- Ancillary equipment - Equipment used with a receiver, transmitter or transceiver to add control or operational features, but not usable alone as the main user function.
- Base station - A Base Transceiver Station (BTS) or Base Station System (BSS) as defined in GSM 01.04.
- Integral antenna equipment - Equipment with an antenna built in or attached without an external connector.
- Manufacturer - The legal entity responsible for placing the product on the market under the EMC Directive.
- Port - A specific interface between the equipment and the electromagnetic environment.
- Radio communications equipment - Equipment with one or more transmitters and/or receivers, used in fixed, mobile or portable applications.
- RXQUAL - A measure of received signal quality used in power control and handover decisions.
Who uses SIST ETS 300 342-2:1999?
Manufacturers of GSM base station radio equipment use SIST ETS 300 342-2:1999 to design products for EMC assessment and to prepare the test documentation. EMC test laboratories use it to configure emissions and immunity tests, select ports, and judge pass/fail performance.
Quality managers, conformity assessors and regulatory bodies use it when they need a common test basis for base station radio equipment and fixed ancillary equipment. Buyers and integrators can use it to check whether a supplier is offering equipment tested to the EMC framework expected for GSM 900 MHz and DCS 1800 MHz installations.
What changed in SIST ETS 300 342-2:1999 from the previous edition?
SIST ETS 300 342-2:1999 is identified as identical to ETS 300 342-2 Edition 1. The document history shown with the standard lists November 1994 as the first edition and January 1996 as the PDF conversion.
Which standards are used with SIST ETS 300 342-2:1999?
| Standard | What it contributes |
|---|---|
| EN 50081-1 | Generic emission standard for residential, commercial and light industry environments |
| EN 50082-1 | Generic immunity standard for residential, commercial and light industry environments |
| ETS 300 339 | General EMC basis for radio equipment |
| 89/336/EEC | The EMC Directive the ETS is intended to support |
| GSM 01.04 | Vocabulary for GSM PLMN terms used in the definitions |
| GSM 05.08 / GSM 05.08-DCS-1800 | Radio subsystem link control, including RXQUAL context |
| GSM 11.20 / GSM 11.20 DCS | Base station specification and several test methods and limits |
| EN 55022 | Measurement methods and limits for emissions from information technology equipment |
| CISPR Publication No. 16-1 | Measuring apparatus and methods for conducted emissions |
| ENV 50140 | Radiated RF immunity test method |
| IEC 801-2 | Electrostatic discharge test method |
| IEC 801-4 | Fast transient test method |
| ENV 50141 | Conducted RF immunity by current clamp injection |
| IEC 1000-4-11 | Voltage dips, short interruptions and voltage variations |
| IEC 1000-4-5 | Surge immunity test method |
What does the SIST ETS 300 342-2:1999 document contain?
SIST ETS 300 342-2:1999 contains the test configurations for transmitters, receivers and fixed ancillary equipment, including how to connect ports, terminate cables and record operating modes. It also includes the exclusion bands, the narrow band response procedure, and the performance criteria used to decide whether EMC stress has affected the communication link.
The emission section gives the methods and limits for enclosure radiation, dc power ports, ac mains ports, base station antenna ports and cabinet radiation. The immunity section gives the methods and levels for RF field, electrostatic discharge, fast transients, RF common mode, voltage dips, surges and antenna-port RF conducted immunity.
The applicability overview tables in clause 7 are especially useful in practice because they show which test applies to which port or equipment category and which external standard is used. That makes the document suitable as a checklist for EMC test planning, laboratory work and conformity assessment.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST ETS 300 342-2:1999 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Radio Equipment and Systems (RES); ElectroMagnetic Compatibility (EMC) for European digital cellular telecommunications system (GSM 900 MHz and DCS 1 800 MHz); Part 2: Base station radio and ancillary equipment". This standard covers: Covers the EMC requirements for GSM 900 MHz & DCS 1800 MHz equipment. The ETS may be used to demonstrate compliance with the requirements of the EMC Directive 89/336/EEC.
Covers the EMC requirements for GSM 900 MHz & DCS 1800 MHz equipment. The ETS may be used to demonstrate compliance with the requirements of the EMC Directive 89/336/EEC.
SIST ETS 300 342-2:1999 is classified under the following ICS (International Classification for Standards) categories: 33.060.20 - Receiving and transmitting equipment; 33.070.50 - Global System for Mobile Communication (GSM); 33.100.01 - Electromagnetic compatibility in general. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST ETS 300 342-2:1999 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Radio Equipment and Systems (RES); ElectroMagnetic Compatibility (EMC) for European digital cellular telecommunications system (GSM 900 MHz and DCS 1 800 MHz); Part 2: Base station radio and ancillary equipment33.100.01Elektromagnetna združljivost na splošnoElectromagnetic compatibility in general33.070.50Globalni sistem za mobilno telekomunikacijo (GSM)Global System for Mobile Communication (GSM)33.060.20Sprejemna in oddajna opremaReceiving and transmitting equipmentICS:Ta slovenski standard je istoveten z:ETS 300 342-2 Edition 1SIST ETS 300 342-2:1999en01-julij-1999SIST ETS 300 342-2:1999SLOVENSKI
STANDARD
EUROPEANETS 300 342-2TELECOMMUNICATIONNovember 1994STANDARDSource: ETSI TC-RESReference: DE/RES-09004-2ICS:33.100Key words:EMC, test, radio communications equipment, GSM, DCSRadio Equipment and Systems (RES);Electro-Magnetic Compatibility (EMC) forEuropean digital cellular telecommunications system(GSM 900 MHz and DCS 1 800 MHz)Part 2: Base station radio and ancillary equipmentETSIEuropean Telecommunications Standards InstituteETSI SecretariatPostal address: F-06921 Sophia Antipolis CEDEX - FRANCEOffice address: 650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCEX.400: c=fr, a=atlas, p=etsi, s=secretariat - Internet: secretariat@etsi.frTel.: +33 92 94 42 00 - Fax: +33 93 65 47 16Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and theforegoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1994. All rights reserved.SIST ETS 300 342-2:1999
Page 2ETS 300 342-2: November 1994Whilst every care has been taken in the preparation and publication of this document, errors in content,typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to"ETSI Editing and Committee Support Dept." at the address shown on the title page.SIST ETS 300 342-2:1999
Page 3ETS 300 342-2: November 1994ContentsForeword.51Scope.72Normative references.73Definitions.84General test conditions.94.1Test conditions.94.2Test conditions for immunity tests.94.3Normal test modulation for base station equipment.94.4Arrangements for test signals at the input of the transmitter.94.5Arrangements for test signals at the output of the transmitter.104.6Arrangements for test signals at the input of the receiver.104.7Arrangements for test signals at the output of the receiver.104.8Receiver and duplex transceiver exclusion band.104.9Transmitter exclusion band.104.10Narrow band responses on receivers and duplex transceivers.105Performance assessment.115.1General.116Performance criteria.126.1Performance criteria for Continuous phenomena applied to Transmitters (CT).126.2Performance criteria for Transient phenomena applied to Transmitters (TT).126.3Performance criteria for Continuous phenomena applied to Receivers (CR).126.4Performance criteria for Transient phenomena applied to Receivers (TR).127Applicability overview tables.137.1Emission.137.2Immunity.138Test methods and limits for emission tests of transmitters and/or receivers and/or ancillaryequipment.148.1Test configuration.148.2Enclosure, ancillary equipment.158.2.1Definition.158.2.2Test method.158.2.3Limits.158.3DC power input/output port.158.3.1Definition.158.3.2Test method.158.3.3Limit for conducted RF signals.158.4AC mains power input/output ports.168.4.1Definition.168.4.2Test method.168.4.3Limit.168.5Antenna port, base stations.168.5.1Definition.168.5.2Test method.168.5.3Test limits.178.6Enclosure, base stations.178.6.1Definition.178.6.2Test method.178.6.3Test limits.18SIST ETS 300 342-2:1999
Page 4ETS 300 342-2: November 19949Test methods and levels for immunity tests of transmitters and/or receivers and/or fixed ancillaryequipment.189.1Test configuration.189.2RF electro-magnetic field (80 to 1 000 MHz).199.2.1Definition.199.2.2Test method and level.199.2.3Performance criteria.199.3Electrostatic discharge.199.3.1Definition.209.3.2Test method and levels.209.3.3Performance criteria.209.4Fast transients common mode.209.4.1Definition.209.4.2Test method and levels.209.4.3Performance criteria.219.5RF common mode, 0,15 MHz to 80 MHz (current clamp injection).219.5.1Definition.219.5.2Test method and level.219.5.3Performance criteria.229.6Voltage dips and interruptions.229.6.1Definition.229.6.2Test method and levels.229.6.3Performance criteria.229.7Surges, common and differential mode.239.7.1Definition.239.7.2Test method and level.239.7.3Performance criteria.239.8RF conducted immunity, antenna port.249.8.1Definition.249.8.2Test method.249.8.3Performance criteria.24History.25SIST ETS 300 342-2:1999
Page 5ETS 300 342-2: November 1994ForewordThis European Telecommunication Standard (ETS) has been prepared by the Radio Equipment andSystems (RES) Technical Committee of the European Telecommunications Standards Institute (ETSI).This ETS is based upon the Generic Standards EN 50081-1 [1] and EN 50082-1 [2], ETS 300 339 [3], andother standards where appropriate, to meet the protection requirements of the Council Directive89/336/EEC [4].Every ETS prepared by ETSI is a voluntary standard. This ETS contains text which may be used forregulatory purposes. This text does not make this ETS mandatory in its status as a standard. However,the ETS can be referenced, wholly or in part, for mandatory application by decisions of regulatory bodies.This ETS is produced in two (2) parts to reflect those requirements for Terminal Equipment and non-Terminal Equipment as follows:Part 1:Mobile and portable radio and ancillary equipment;Part 2:Base station radio and ancillary equipment.Proposed transposition datesDate of latest announcement of this ETS (doa):28 February 1995Date of latest publication of new National Standardor endorsement of this ETS (dop/e):31 August 1995Date of withdrawal of any conflicting National Standard (dow):31 August 1995SIST ETS 300 342-2:1999
Page 6ETS 300 342-2: November 1994Blank pageSIST ETS 300 342-2:1999
Page 7ETS 300 342-2: November 19941ScopeThis European Telecommunication Standard (ETS) covers the assessment of radio communication andancillary equipment in respect of Electro-Magnetic Compatibility (EMC).This ETS specifies the applicable EMC tests, the methods of measurements, the limits and the minimumperformance criteria for GSM 900 MHz and DCS 1 800 MHz digital public cellular base station radioequipment, transmitting and receiving speech and/or data, and the associated ancillary equipment.The environment classification used in this ETS refers to the environment classification used in theGeneric Standards EN 50081-1 [1] and EN 50082-1 [2].For the purposes of this ETS, Base Transceiver Stations (BTSs), and single cabinet Base StationSystems (BSSs), are considered to be radio communications equipment.For the purposes of this ETS the manufacturer may declare that Base Station Controllers (BSCs) andTranscoders (XC) are to be considered as ancillary equipment (see clause 3 for the definition of ancillaryequipment).Mobile services Switching Centres (MSCs) and Echo Cancellers (ECs) are not covered by this ETS.The EMC requirements have been selected to ensure an adequate level of compatibility for apparatus atresidential, commercial, and light industrial environments. The levels however, do not cover extremecases which may occur in any location but with low probability of occurrence.This ETS may not cover those cases where a potential source of interference which is producingindividually repeated transient phenomena, or a continuous phenomena, is permanently present, e.g. aradar or broadcast site in the near vicinity. In such a case it may be necessary to use special protectionapplied to either the source of interference, or the interfered part, or both.Compliance of radio equipment to the requirements of this ETS does not signify compliance to anyrequirement related to the use of the equipment (i.e. licensing requirements).Compliance to this ETS does not signify compliance to any safety requirement. However, it is theresponsibility of the assessor of the equipment that any observation regarding the equipment becomingdangerous or unsafe as a result of the application of the tests of this ETS, should be recorded in the testreport.2Normative referencesThis ETS incorporates, by dated or undated reference, provisions from other publications. Thesenormative references are cited at the appropriate places in the text and the publications listed hereafter.For dated references, subsequent amendments to or revisions of any of these publications apply to thisETS only when incorporated in it by amendment or revision. For undated references, the latest edition ofthe publication referred to applies.[1]EN 50081-1 (1992): "Electromagnetic compatibility - Generic emission standard.Part 1: Residential, commercial and light industry".[2]EN 50082-1 (1992): "Electromagnetic compatibility - Generic immunity standard.Part 1: Residential, commercial and light industry".[3]Draft prETS 300 339: "Radio Equipment and Systems (RES) - General Electro-Magnetic Compatibility (EMC) for radio equipment".[4]89/336/EEC (1989): "Council Directive on the approximation of the laws of theMember States relating to electromagnetic compatibility".[5]GSM 01.04: "European digital cellular telecommunications system - Vocabularyin a GSM PLMN".SIST ETS 300 342-2:1999
Page 8ETS 300 342-2: November 1994[6]GSM 05.08/GSM 05.08-DCS-1800: "European digital cellulartelecommunications system - Radio Subsystem Link Control".[7]GSM 11.20/GSM 11.20 DCS: "European digital cellular telecommunicationssystem - Base Station Specification".[8]EN 55022 (1987): "Limits and methods of measurement of radio interferencecharacteristics of information technology equipment".[9]CISPR Publication No. 16-1: "Specification for radio disturbance and immunitymeasuring apparatus and methods".[10]ENV 50140: "Basic immunity standard - Radiated, radio frequency,electromagnetic fields".[11]IEC 801-2 (second edition 1991) Part 2: "Electrostatic discharge requirements".[12]IEC 801-4 (1988) Part 4: "Electrical fast transients / burst requirements".[13]ENV 50141: "Basic immunity standard - Conducted disturbances induced byradio frequency fields".[14]IEC 1000-4-11: "Voltage dips, short interruptions and voltage variations.Immunity tests".[15]IEC 1000-4-5: "Surge immunity requirements".3DefinitionsFor the purposes of this ETS, the following definitions apply.ancillary equipment: Equipment (apparatus), used in connection with a receiver, transmitter ortransceiver, is considered as an ancillary equipment (apparatus) if:-the equipment is intended for use in conjunction with a receiver, transmitter or transceiver toprovide additional operational and/or control features to the radio equipment (e.g. to extend controlto another position or location); and-the equipment cannot be used on a stand alone basis to provide user functions independently of areceiver, transmitter or transceiver; and-the receiver, transmitter or transceiver to which it is connected, is capable of providing someintended operation such as transmitting and/or receiving without the ancillary equipment (i.e. it isnot a sub-unit of the main equipment essential to the main equipment basic functions).base station: A base station is a BTS or BSS as defined in GSM 01.04 [5].integral antenna equipment: Equipment fitted with an antenna designed to be connected to theequipment without the use of an external connector and considered to be part of the equipment. Anintegral antenna may be fitted internally or externally to the equipment.manufacturer: The legal entity responsible under the terms of the Council Directive, 89/336/EEC [4], forplacing the product on the market.port: A particular interface of the specified equipment (apparatus) with the electromagnetic environment.radio communications equipment: An apparatus which includes one or more transmitters and/orreceivers and/or parts thereof. This type of equipment (apparatus) can be used in a fixed, mobile or aportable application.SIST ETS 300 342-2:1999
Page 9ETS 300 342-2: November 1994RXQUAL: A measure of the received signal quality, which is generated by the base station for use as acriterion in the RF power control and handover processes. For more information see GSM 05.08 [6],subclause 8.2.4General test conditions4.1Test conditionsThe equipment shall be tested under normal test conditions contained in the relevant product and basicstandards or in the information accompanying the equipment, which are within the manufacturersdeclared range of humidity, temperature, and supply voltage.The test conditions shall be recorded in the test report.The test configuration shall be as close to normal intended use as possible and shall be recorded in thetest report.The test set ups for transmitters and receivers are described separately for the sake of clarity. However, itis not necessarily excluded that the test of the transmitter section and receiver section of the EUT can becarried out simultaneously to reduce test time.4.2Test conditions for immunity testsFor the immunity tests of transmitters, the transmitter shall be operated at its maximum rated outputpower, up to and not exceeding a maximum of 20 W, modulated with normal test modulation (seesubclauses 4.3 and 4.4). A communication link shall be established (see subclause 4.5).For the immunity tests of receivers, the wanted input signal, coupled to the receiver, shall be modulatedwith normal test modulation (see subclauses 4.3 and 4.6). A communication link shall be established (seesubclause 4.7).For the immunity tests of duplex transceivers, the wanted input signal, coupled to the receiver, shall bemodulated with normal test modulation (see subclauses 4.3 and 4.6). The transmitter shall be operated atits maximum rated output power, up to and not exceeding a maximum of 20 W. A communication linkshall be established (see subclause 4.5).4.3Normal test modulation for base station equipmentA communication link shall be set up with a suitable mobile or mobile simulator (hereafter called "the testsystem").The wanted RF input signal nominal frequency shall be selected by setting the Absolute Radio FrequencyChannel Number (AFRCN) to an appropriate number, e.g. in the case of GSM 900 MHz this will be 60 to65.The following conditions shall be met:-the EUT shall be commanded to operate at maximum transmit power, up to, and not exceeding, amaximum of 20 W;-the uplink and downlink RXQUAL shall be monitored.4.4Arrangements for test signals at the input of the transmitterA communication link shall be set up between the EUT and the test system.SIST ETS 300 342-2:1999
Page 10ETS 300 342-2: November 19944.5Arrangements for test signals at the output of the transmitterThe test system shall be located outside of the test environment.The wanted signal to establish a communication link shall be delivered from the antenna connector by acoaxial cable. Adequate measures shall be taken to minimise the effect of unwanted currents on theexternal conductor of the coaxial cable at the point of entry to the equipment. Adequate measures shallalso be taken to avoid the effect of the unwanted signal on the measuring equipment.4.6Arrangements for test signals at the input of the receiverThe test system shall be located outside of the test environment.The wanted signal to establish a communication link shall be presented to the antenna connector by acoaxial cable. Adequate measures shall be taken to minimise the effect of unwanted currents on theexternal conductor of the coaxial cable at the point of entry to the equipment. The source of the wantedinput signal shall be located outside of the test environment and shall be at a nominal value of 66 dBµVemf except for the tests carried out in subclause 9.8.2, where the wanted signal level shall be inaccordance with GSM 11.20 [7].4.7Arrangements for test signals at the output of the receiverThe audio frequency output of the equipment should be coupled via a non-metallic acoustic tube to asuitable audio level meter outside of the test environment.Where it is not practical to use a non metallic tube, then other means of connecting the receiver output toa suitable audio level meter shall be provided and recorded in the test report. Precautions shall be takento ensure that any effect on the test is minimized.4.8Receiver and duplex transceiver exclusion bandThe exclusion band for receivers and the receivers of transceivers is the band of frequencies over whichno radiated immunity tests are made.The lower frequency of the exclusion band is the lower frequency of the receive band of the EUT minus6 %.The upper frequency of the exclusion band is the upper frequency of the receive band of the EUT plus5 %.4.9Transmitter exclusion bandThe exclusion band for transmitters extends ± 200 kHz from the nominal operating frequency of thetransmitter.4.10Narrow band responses on receivers and duplex transceiversResponses on receivers or duplex transceivers occurring during the test at discrete frequencies which arenarrow band responses (spurious responses), are identified by the following method:-if during an immunity test the RXQUAL being monitored goes outside the specified figure, it isnecessary to establish whether the RXQUAL increase is due to a narrow band response or to awide band phenomenon. Therefore, the test shall be repeated with the unwanted signal frequencyincreased, and then decreased by 400 kHz;-if the RXQUAL increase disappears in either or both of the above 400 kHz offset cases, then theresponse is considered as a narrow band response;-if the RXQUAL increase does not disappear, this may be due to the fact that the offset has madethe frequency of the unwanted signal correspond to the frequency of another narrow bandresponse. Under these circumstances the procedure is repeated with the increase and decrease ofthe frequency of the unwanted signal set to 500 kHz;SIST ETS 300 342-2:1999
Page 11ETS 300 342-2: November 1994-if the RXQUAL increase still does not disappear with the increased and/or decreased frequency, thephenomena is considered wide band and therefore an EMC problem and the equipment fails thetest.Narrow band responses are disregarded.5Performance assessment5.1GeneralThe manufacturer shall at the time of submission of the equipment for test, supply the followinginformation which shall be recorded in the test report:-any primary functions of the radio equipment additional to those specified in clause 6, as requestedby the manufacturer, to be tested during and after the EMC testing;-the intended functions of the EUT which shall be in accordance with the documentationaccompanying the equipment;-the user-control functions and stored data that are required for normal operation and the method tobe used to assess whether these have been lost after EMC stress;-the ancillary equipment to be combined with the radio equipment for testing;-the ancillary equipment submitted for test on a stand alone basis, not combined with the radioequipment;-an exhaustive list of ports, classified as either power or signal/control. Power ports shall further beclassified as ac or dc power.If the equipment is a radio equipment of a non-specialised nature or a radio equipment combined with anancillary equipment, the test modulation, test arrangement etc. as required in clause 4 shall apply.If the ancillary equipment is intended for use at a remote location, tests to all applicable immunity clausesand emission clauses of this ETS are mandatory.In the case of ancillary equipment tested on a stand alone basis and/or radio equipment of a specialisednature (see clause 6) the manufacturer shall define the method of test to determine the acceptable level ofperformance or degradation of performance during and/or after the test. Under these circumstances themanufacturer shall also provide the following information:-the pass/fail criteria for the EUT;-the method of observing a degradation of performance of the equipment.The degradation of performance assessment which shall be carried out during and/or at the conclusion ofthe tests, shall be simple, but at the same time give adequate proof that the essential functions of theequipment are operational.An ancillary equipment may, at the manufacturer's discretion, be declared compliant separately from areceiver, transmitter or transceiver to all the applicable immunity and emission clauses of this ETS.Alternatively, at the manufacturer's discretion, an ancillary equipment may be declared compliant toanother harmonised EMC standard.Either way, this compliance may enable the ancillary equipment to be used with different receivers,transmitters or transceivers.An ancillary equipment may, at the manufacturer's discretion, be tested with it connected to a receiver,transmitter or transceiver during the tests, in which case compliance shall be demonstrated to theappropriate clauses of this ETS.SIST ETS 300 342-2:1999
Page 12ETS 300 342-2: November 19946Performance criteriaThe establishment and maintenance of a communications link, and the assessment of RXQUAL are usedas the performance criteria to ensure that all the primary functions of the transmitter and receiver areevaluated during the immunity tests.Specifically the equipment shall meet the minimum performance criteria as specified in the followingsubclauses as appropriate.If an equipment is of a specialised nature, such that the performance criteria described in the followingsubclauses are not appropriate, then the manufacturer shall declare, for inclusion in the test report, hisown specification for an acceptable level of performance or degradation of performance during and/orafter testing, as required by this ETS. The performance specification shall be included in the productdescription and documentation. The performance criteria specified by the manufacturer shall, however,give the same degree of immunity protection as called for in the following subclauses.6.1Performance criteria for Continuous phenomena applied to Transmitters (CT)A communications link (see subclauses 4.5 and 4.6) shall be established at the start of the test, andmaintained during the test.For base stations the RXQUAL of the downlink shall not exceed three (3) measured during the testsequence.At the conclusion of the test the EUT shall operate as intended with no loss of user control functions orstored data, and the communication link shall have been maintained.Where the EUT is a transmitter only, tests shall be performed with the EUT in standby m
...