oSIST prEN IEC 62680-1-2:2026
(Main)Universal serial bus interfaces for data and power - Part 1-2: Common components - USB power delivery specification (Fast track)
- Status
- Not Published
- Public Enquiry End Date
- 30-Dec-2026
- Technical Committee
- AVM - Audio, video and multimedia systems and equipment
- Current Stage
- 4020 - Public enquire (PE) (Adopted Project)
- Start Date
- 10-Nov-2026
- Due Date
- 30-Mar-2027
oSIST prEN IEC 62680-1-2:2026 is a CLC draft of the USB Power Delivery specification for Universal Serial Bus interfaces for data and power. It defines how USB Power Delivery (USB PD) sources, sinks, ports, cables and cable plugs advertise capability, negotiate power, and exchange control and data messages so a connection can move from the default state to an explicit contract.
What does oSIST prEN IEC 62680-1-2:2026 specify?
oSIST prEN IEC 62680-1-2:2026 specifies the common USB PD components needed to deliver and negotiate power over USB, together with the communication rules that support that negotiation. The document is organized from architecture and terminology through power rules, electrical behavior, the physical layer, message formats, message usage, state diagrams and fast role swap timing.
Clause 1 introduces cable, connector and operational concepts, including the USB PD roles used by source, sink, dual-role and cable-related functions. Clause 2 sets the conventions, related documents and terms used throughout the specification. Clauses 3 to 7 cover power requirements, electrical requirements, the PD communications physical layer, message definitions and message usage; later clauses add the state-machine material and fast role swap timing and parameters shown in the table of contents.
What are the key requirements of oSIST prEN IEC 62680-1-2:2026?
Power rules for sources and sinks
Clause 3 defines the power capabilities that a compliant Source Port advertises and a compliant Sink Port can request. It distinguishes Guaranteed Capability Port and Managed Capability Port, which matters because the source may offer either fixed or dynamically managed output power.
Clause 3 also separates standard power range (SPR) behavior from extended power range (EPR) behavior. The source-side rules cover fixed, variable and battery supplies, SPR Programmable Power Supply (PPS), SPR Adjustable Voltage Supply (AVS) and EPR options, so implementers must choose which power objects and operating range they support and advertise them consistently.
The sink-side rules cover how a Sink Port uses the advertised power, including sink requirements, accessory support and PDUSB device requirements. In practice, that means the sink must request power within the limits of the selected contract and manage its own consumption according to the negotiated capability.
Electrical behavior during negotiation and transitions
Clause 4 gives the electrical behavior that accompanies power negotiation. It covers source bulk capacitance, source transitions, sink standby and suspend behavior, robust over-current, over-voltage and over-temperature protection, and the handling of detach events.
The source transition rules define controlled voltage changes and when the source may transition faster than the normal slew limits, such as first applying VBUS after attach, changing power role to Source, or moving from vSafe0V to vSafe5V during a Hard Reset. For hardware design, this is the part that drives converter response, protection thresholds and power-path timing.
Clause 4 also defines how a source should react to detach and how quickly it must return to vSafe0V. That matters because a compliant design must remove power safely when the cable or device disconnects, not just stop negotiating.
On the sink side, Clause 4 covers bulk capacitance, standby power, zero negotiated power, transient load behavior, peak current operation and robust sink protection. The practical effect is that a sink cannot assume unlimited inrush or overload margin - it must stay within the negotiated current and handle faults and disconnects safely.
Dual-role behavior is also defined here. Clause 4 describes power role swap, swap standby timing, hard reset response and VCONN power cycle behavior, so a dual-role device needs state logic for changing roles without violating timing or connector power rules.
Physical-layer signaling on the CC wire
Clause 5 defines the PD communications physical layer on the Configuration Channel (CC). It uses Bi-phase Mark Coding (BMC), preamble, packet formation, reset signaling, reception rules and electrical masks for transmitter and receiver behavior.
This matters because USB PD signaling is not just abstract messaging - the controller and PHY have to generate and decode the required waveforms on the CC line. The clause also covers collision avoidance and built-in self-test (BIST), which are important for interoperable implementations and test validation.
Message formats and data objects
Clause 6 defines the PD message structure: control messages, data messages, extended messages, headers, message IDs, chunking, vendor and product IDs, and the fields carried in each message type. It includes the core power negotiation messages such as Source_Capabilities, Sink_Capabilities and Request, plus role-swap, reset, status, PPS, battery, manufacturer and firmware-related messages.
The same clause defines the power data objects (PDOs), sink request data objects and extended capability fields used to advertise or request power. For implementers, this is where the firmware learns exactly how to encode the capabilities that a source advertises and the operating point that a sink requests.
Clause 6 also covers vendor-defined messages, structured and unstructured VDM handling, Discover Identity, Discover SVIDs, Discover Modes, Enter Mode and Exit Mode. That is the part used when a product needs to identify itself, expose supported modes or support alternate-mode discovery over USB PD.
Message usage, sequences and timers
Clause 7 explains how the messages are used in actual exchanges. It covers soft reset, data reset, hard reset, cable reset, collision avoidance, message discarding and the applicability tables that govern when a message is valid.
Clause 7 then sets out the atomic message sequences for power negotiation, power role swap, fast role swap, data role swap, VCONN swap, alert handling, Get Status and Get PPS Status. In practice, this is the policy-engine part of the standard: it tells software what sequence to send, when to wait, and how to recover if a partner rejects, waits or discards a message.
The later timing material and state diagrams support the same behavior at implementation level. The document includes fast role swap timers and parameters, which matter when a source is lost and the system must change power roles quickly.
What terms does oSIST prEN IEC 62680-1-2:2026 define?
- Default Contract - The initial non-negotiated power state after attachment, with 5 V as the default voltage and current limited by the advertised USB-C capability.
- Explicit Contract - The state reached after PD power negotiation, when Source and Sink have agreed the active power contract.
- Source Port - The port that provides power and advertises source capabilities to a partner.
- Sink Port - The port that receives power and requests the voltage and current it needs.
- Dual-Role Power (DRP) - A port that can change its power role through the PR_Swap process.
- Dual-Role Data (DRD) - A port that can change its data role through the DR_Swap process.
- Power Data Object (PDO) - The data object used to publish source or sink power capabilities in Source_Capabilities, EPR_Source_Capabilities, Sink_Capabilities or EPR_Sink_Capabilities messages.
- Programmable Power Supply (PPS) - An optional power mode where the source supports requested voltage and current values within the defined PPS range.
- Extended Power Range (EPR) - The higher-power operating range used when the source and sink support EPR mode.
- Fast Role Swap (FRS) - The rapid exchange of source and sink power roles when an external power supply is removed.
Who uses oSIST prEN IEC 62680-1-2:2026?
oSIST prEN IEC 62680-1-2:2026 is used by engineers who design USB PD sources, sinks, controllers, cables, cable plugs and USB-C connected products. It is also used by firmware and policy-engine developers who implement the negotiation state machines, message handling and reset behavior.
Test laboratories and compliance teams use it to verify signaling, timing, packet formats, PDO/APDO content and role-swap behavior. Buyers, quality managers and platform integrators use it to check whether a product supports the power range, messaging features and device roles needed for a USB-C system.
It is relevant to power adapters, laptops, docks, hubs, peripherals, battery-powered devices and products that expose manufacturer, battery, country or alternate-mode information over USB PD.
Which standards are used with oSIST prEN IEC 62680-1-2:2026?
- [USB-C] - Provides the connector, CC behavior, VBUS and VCONN concepts, detach behavior and other Type-C electrical rules used throughout the document.
- [IEC 60958-1] - Serves as the coding reference cited for BMC as a form of Manchester coding.
- [ISO 3166] - Defines the alpha-2 country codes used in Country_Info and related country-code messages.
- [IEC 62368-1] - Provides the TS1 and TS2 touch-temperature limits referenced for source and sink touch-temperature reporting.
- [USB2], [USB3] and [USB4] - Supply the data-capability and tunneling context used in capability fields, cable speed reporting and host/device support declarations.
- [TBT3] - Provides the Thunderbolt support context used in capability reporting and alternate-mode-related fields.
What does the oSIST prEN IEC 62680-1-2:2026 document contain?
The document contains figures for the USB PD device architecture, source and sink transition envelopes, BMC waveforms and state diagrams for PD behavior. It also contains tables for source and sink capability fields, PDO and APDO formats, message headers, alert data objects, extended message fields, battery and manufacturer information, timers and FRS parameters.
Several clauses are written as procedural sequences, such as power negotiation, hard reset, data reset, VCONN power cycle and role-swap handling. Those sequences are what implementers use to code policy engines and to build interoperability test cases.
The later sections also include detailed field definitions for source capabilities extended, sink capabilities extended, revision, status, PPS status, country information, security and firmware update messages. That content is used for design, conformance testing and protocol validation rather than for general product marketing or end-user operation.
Relations
- Effective Date
- 13-Oct-2026
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.
Sponsored listings
Frequently Asked Questions
oSIST prEN IEC 62680-1-2:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Universal serial bus interfaces for data and power - Part 1-2: Common components - USB power delivery specification (Fast track)". This standard covers: Universal serial bus interfaces for data and power - Part 1-2: Common components - USB power delivery specification (Fast track)
Universal serial bus interfaces for data and power - Part 1-2: Common components - USB power delivery specification (Fast track)
oSIST prEN IEC 62680-1-2:2026 is classified under the following ICS (International Classification for Standards) categories: 29.220 - Galvanic cells and batteries; 33.120 - Components and accessories for telecommunications equipment; 35.200 - Interface and interconnection equipment. The ICS classification helps identify the subject area and facilitates finding related standards.
oSIST prEN IEC 62680-1-2:2026 has the following relationships with other standards: It is inter standard links to SIST EN IEC 62680-1-2:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
oSIST prEN IEC 62680-1-2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 4.1.5.2. Output Over-Voltage Protection
- 4.1.5.3. Over-Temperature Protection
- 4.1.5.4. vSafe5V Externally Applied to Ports Supplying vSafe5V
- 4.1.5.5. Detach
- 4.1.6. Source Peak Current Operation
- 4.1.7. Source Capabilities Extended Parameters
- 4.1.7.1. Load Step Slew Rate
- 4.1.7.2. Load Step Magnitude
- 4.1.7.3. Holdup Time Field
- 4.1.7.4. Compliance Field
- 4.1.7.5. Batteries
- 4.2. Sink Requirements
- 4.2.1. Behavioral Aspects
- 4.2.2. Sink Bulk Capacitance
- 4.2.3. Sink Standby
- 4.2.4. Suspend Power Consumption
- 4.2.5. Zero Negotiated Power
- 4.2.6. Transient Load Behavior
- 4.2.7. Considerations for Current Limit in PPS Mode
- 4.2.8. Sink Peak Current Operation
- 4.2.9. Robust Sink Operation
- 4.2.9.1. Sink Bulk Capacitance Discharge at Detach
- 4.2.9.2. Sink Over-Current Protection
- 4.2.9.3. Sink Over-Voltage Protection
- 4.2.9.4. Sink Over-Temperature Protection
- 4.3. Dual Role Ports
- 4.3.1. Swap Standby for the Initial Source
- 4.3.2. Swap Standby for the Initial Sink
- 4.3.3. Power Role Swap Sequence
- 4.4. Response to Hard Resets
- 4.4.1. Hard Reset Sequence
- 4.5. Transitions
- 4.5.1. Fixed and AVS transitions
- 4.5.1.1. Large-step voltage increases (Fixed or AVS)
- 4.5.1.2. Small-step voltage increases (AVS)
- 4.5.1.3. Unchanged or decreased voltage transitions (current unchanged, increased, or de- creased)
- 4.5.2. PPS voltage or current changes
- 4.5.2.1. PPS voltage transitions (CV Mode)
- 4.5.2.2. PPS current transitions (CL Mode)
- 4.6. VCONN Power Cycle
- 4.7. Electrical Parameters
- 4.7.1. Source Electrical Parameters
- 4.7.2. Sink Electrical Parameters
- 4.7.3. Common Electrical Parameters
- 5. PD Communications Physical Layer
- 5.1. Overview
- 5.2. Signaling Through DC Biasing
- 5.2.1. Power Role Indication
- 5.2.2. Collision Avoidance
- 5.2.2.1. Definition of Idle
- 5.3. BMC Signaling
- 5.3.1. Transmission
- 5.3.1.1. Packet Formation
- 5.3.1.2. Resets
...