Fixed inductors for electromagnetic interference suppression - Part 2: Sectional specification

Applies to fixed conductors designed for electromagnetic interference suppression and which fall within the scope of the generic spedification, EN 60938-1. It is restricted to fixed inductors for which safety tests are appropriate. This implies that inductors specified according to this specification will either be connected to mains supplies, when compliance with the mandatory test of table 1 is necessary, or used in other circuit positions where the equipment specification prescribes that some or all of these safety tests are required. It applies to fixed inductors which will be connected to an a.c. mains or other supply with a nominal voltage not exceeding 1 000 V a.c.(r.m.s.) or d.c. between conductors and with a nominal frequency not exceeding 400 Hz.

Drosseln zur Unterdrückung elektromagnetischer Störungen - Teil 2: Rahmenspezifikation

Inductances fixes d'antiparasitage - Partie 2: Spécification intermédiaire

S'applique aux inductances fixes d'antiparasitage qui font partie du domaine d'application de la spécification générique. L'objet de cette norme est de prescrire les exigences normales pour la protection contre les dangers de choc électrique et les valeurs normales des caractéristiques, et de choisir, dans la spécification générique, les méthodes d'essai appropriées et de fixer les exigences générales pour les inductances d'antiparasitage.

Fixed inductors for electromagnetic interference suppression - Part 2: Sectional specification (IEC 60938-2:1999)

General Information

Status
Published
Publication Date
14-Dec-1999
Withdrawal Date
30-Nov-2002
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
6060 - Document made available - Publishing
Start Date
15-Dec-1999
Completion Date
15-Dec-1999

Relations

Buy Standard

Standard
EN 60938-2:2002
English language
36 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Fixed inductors for electromagnetic interference suppression - Part 2: Sectional specification (IEC 60938-2:1999)Drosseln zur Unterdrückung elektromagnetischer Störungen -- Teil 2: RahmenspezifikationInductances fixes d'antiparasitage -- Partie 2: Spécification intermédiaireFixed inductors for electromagnetic interference suppression -- Part 2: Sectional specification29.180Transformatorji. DušilkeTransformers. ReactorsICS:Ta slovenski standard je istoveten z:EN 60938-2:1999SIST EN 60938-2:2002en01-september-2002SIST EN 60938-2:2002SLOVENSKI
STANDARD
IEC 60938-2Edition 2.0 1999-11INTERNATIONAL STANDARD NORME INTERNATIONALEFixed inductors for electromagnetic interference suppression –
Part 2: Sectional specification
Inductances fixes d'antiparasitage –
Partie 2: Spécification intermédiaire
INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE VICS 29.100.10; 31.020 PRICE CODECODE PRIXISBN 2-8318-9906-0QC 280100
– 2 – 60938-2 © IEC:1999 CONTENTS FOREWORD.4 1 General.6 1.1 Scope.6 1.2 Object.6 1.3 Normative references.6 1.4 Information to be given in a detail specification.7 1.4.1 General.7 1.4.2 Outline drawing and dimensions.7 1.4.3 Mounting.8 1.4.4 Ratings and characteristics.8 1.4.5 Marking.8 1.5 Definitions.8 1.6 Marking.8 2 Preferred ratings and characteristics.9 2.1 Climatic categories.9 2.2 Values of ratings.9 2.2.1 Rated inductance and tolerance.9 2.2.2 Rated voltage (UR).9 2.2.3 Category voltage (UC).9 2.2.4 Rated temperature.9 2.2.5 Rated current.9 2.2.6 Passive flammability.9 3 Quality assessment procedures.10 3.1 Primary stage of manufacture.10 3.2 Structurally similar inductors.10 3.3 Certified records of released lots.10 3.4 Qualification approval.10 3.4.1 Qualification approval on the basis of the fixed sample size procedures.10 3.5 Quality conformance inspection.13 3.5.1 Formation of inspection lots.13 3.5.2 Test schedule.14 3.5.3 Delayed delivery.14 4 Test and measurement procedures.14 4.1 Visual examination and check of dimensions.14 4.1.1 Dimensions (gauging).14 4.1.2 Dimensions (detail).14 4.2 Voltage proof.14 4.3 Insulation resistance.15 4.4 Inductance.15 4.5 DC line resistance.15 4.6 Robustness of terminations.16 4.7 Resistance to soldering heat.16 4.7.1 Conditions.16 4.7.2 Final inspection, measurements and requirements.16 4.8 Solderability.16 4.9 Rapid change of temperature.16 SIST EN 60938-2:2002

60938-2 © IEC:1999 – 3 – 4.10 Vibration.16 4.11 Bump.17 4.12 Shock.17 4.13 Container sealing.18 4.14 Climatic sequence.18 4.14.1 Initial measurements.18 4.14.2 Dry heat.18 4.14.3 Damp heat, cyclic, test Db, first cycle.18 4.14.4 Cold.18 4.14.5 Low air pressure.18 4.14.6 Damp heat, cyclic, test Db, remaining cycles.18 4.14.7 Final inspection, measurements and requirements.19 4.15 Damp heat, steady state.19 4.15.1 Final inspection, measurements and requirements.19 4.16 Temperature rise (applies only to inductors with a mass > 5 g).19 4.16.1 Test method.19 4.16.2 Requirements.20 4.17 Impulse voltage (applies to inductors with more than one winding).20 4.17.1 Initial measurements.20 4.17.2 Requirements.20 4.18 Endurance.20 4.18.1 Test conditions – Endurance current test.20 4.18.2 Test conditions – Endurance voltage test between terminations (applies to inductors with more than one winding).21 4.19 Passive flammability (if applicable).21 4.20 Component solvent resistance (if applicable).21 4.21 Solvent resistance of marking (if applicable).21 Annex A (normative)
Test schedule for safety tests only approval.22 Annex B (normative)
Test schedule for safety tests and performance tests for qualification approval, assessment level D.25 Annex C (normative)
Example of a suitable circuit for the endurance test voltage.30 Annex D (normative)
Declaration of design (confidential to the manufacturer and the certification body).31 Annex E (normative)
Test methods for thyristor electromagnetic
interference suppression inductors.32
Figure C.1 – Endurance test circuit.30 Figure E.1 – Test circuit for temperature rise.32 Figure E.2 – Test circuit for interference voltage attenuation.33
Table 1 – Sampling plan for safety tests only.12 Table 2 – Sampling plan for safety tests and performance tests, assessment level D.13 Table 3 – Measuring points.15 Table 4 – Acceleration.16 Table 5 – Sweep cycles.17 Table 6 – Preferred severities.18
– 4 – 60938-2 © IEC:1999 INTERNATIONAL ELECTROTECHNICAL COMMISSION ____________
FIXED INDUCTORS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION –
Part 2: Sectional specification
FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC sha
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.