Abstract

1.1 This document specifies the minimum requirements for safety and performance of some optional specific permanently installed equipment on firefighting and rescue service vehicles, operated by trained persons, as designated in EN 1846 1:2011 and specified in EN 1846 2:2024.
NOTE 1   Categories and mass classes of these vehicles are given in EN 1846 1:2011.
NOTE 2   Vehicle means ground vehicles which can also drive on rails and amphibious vehicles.
The permanently installed equipment covered by this document is given below:
-   water installation;
-   additive installation;
-   monitor;
-   equipment gantries;
-   demounting systems.
This document covers also the use of wireless control systems.
NOTE 3   This document is assumed to be read in conjunction with any national regulations in force for vehicles using the public roads and with any EU Directives and associated EFTA regulations in force relevant to vehicles and their equipment.
For the purposes of this document, the normal ambient temperature range is –15 °C to +40 °C.
For equipment to be used at temperature outside this temperature range, the particular temperature range is specified by the user. A risk assessment determines any need for additional precautions.
1.2 This document does not deal with the following types of equipment:
-   all control systems outside of the cabin related to hook arm system;
-   provisions for non-firefighting removable equipment driven by PTO.
1.3 This document deals with the technical requirements to minimize the hazards listed in Annex A which can arise during operational use, routine checking and maintenance of firefighting and rescue service vehicles.
It does not cover the hazards generated by:
-   non-permanently installed equipment i.e. portable equipment carried on the vehicle;
-   use in potentially explosive atmospheres;
-   commissioning and decommissioning;
-   noise (as permanently installed equipment cannot be operated separately from the vehicle, this hazard is covered in EN 1846 2:2024);
-   electromagnetic compatibility;
-   cyber security;
-   cyber safety.
Additional measures not dealt with in this document can be necessary for specific use (e.g. fire in natural environment, flooding, etc.).
1.4 This document is not applicable to the equipment which is manufactured before its date of publication by CEN.

Status
Published
Publication Date
11-Jan-2027
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
14-Oct-2026
Due Date
12-Jan-2027
Completion Date
12-Jan-2027

Buy Documents

Standard

EN 1846-3:2026

English language (60 pages)
Preview
Preview
e-Library read for
×1 day

EN 1846-3:2026 is a CEN standard for firefighting and rescue service vehicles that sets minimum safety and performance requirements for selected permanently installed equipment. It covers water installation, additive installation, monitors, equipment gantries, demounting systems and wireless control systems for vehicles operated by trained persons. For engineers, buyers and quality managers, it defines what must be designed, verified, marked and documented when these vehicle systems are supplied or integrated.

What does EN 1846-3:2026 specify?

EN 1846-3:2026 specifies the minimum requirements for permanently installed equipment on firefighting and rescue service vehicles as defined by EN 1846-1 and EN 1846-2. It focuses on the equipment that stays with the vehicle and on the hazards that can arise during operation, checking and maintenance.

The scope includes water installation, additive installation, monitor, equipment gantries and demounting systems, and it also covers wireless control systems. It applies to vehicles operated by trained persons and assumes use together with national road rules and applicable EU and EFTA vehicle legislation.

The document is organized into scope, normative references, terms and definitions, symbols and abbreviated terms, requirements and verifications, information for use, and annexes.

AnnexWhat it covers
Annex AList of significant hazards
Annex BTheoretical stability calculation for hook arm systems
Annex CUsable capacity of the water tank
Annex DMonitor throw measurement
Annex EVariation of suction height with atmospheric pressure and water temperature
Annex FExamples of other demounting systems
Annex ZARelationship with Regulation (EU) 2023/1230

What are the key requirements of EN 1846-3:2026?

EN 1846-3:2026 combines general safety rules with equipment-specific requirements and test or verification methods. In practice, it tells the manufacturer what to build, what to measure, and what to show in the instruction handbook.

General safety, controls and construction

EN 1846-3:2026 requires permanently installed equipment to follow EN 1846-2 plus the additional safety measures in Clause 5, and to use EN ISO 12100 principles for remaining hazards. Each operating position needs a stop control, controls must be usable without tools where intended, and the equipment must not interfere with other vehicle systems.

The document also requires corrosion resistance, protection against water and dirt build-up, and a design that withstands normal operational stresses. For the pump operating position, it specifies the main controls and indicators that must be present, such as pump speed control, pressure indication, vacuum indication where relevant, malfunction warning and tank level indication.

Water installation

For the water installation, EN 1846-3:2026 requires a required performance level (PL) for pressure regulation and outlet opening control, and it sets pressure, speed and pressure-deviation limits for pumps and pipework. It also requires the tank and pipework to be drainable, flushable where water/additive mixture is used, and protected against frost when needed.

Access and use are also controlled: supply and delivery connections have height and angle rules, blank caps must not create trapped pressure, the final delivery needs shut-off valves, and operating instruments outside the cab need an IP65 level of protection. For hosereel systems, powered rewind needs hold-to-run control and protection against unintended unwinding.

Additive installation

For additive installation, EN 1846-3:2026 requires pressure resistance, drainage, flushing and proportioning that achieves the specified mix and delivery rates. Where positive pressure proportioning systems (PPPS) or compressed air foam systems (CAFS) are installed, they also have to meet EN 16327.

The additive tank must have a declared usable capacity, controlled filling, overflow prevention and a level indicator visible from the water pump operating position. The document also requires the instruction handbook to state which liquids are suitable for the materials used and how to flush the system safely.

Monitor, bracket assembly and demounting systems

For the monitor, EN 1846-3:2026 requires safety-related control parts with PL b, direction identification if the monitor is not visible, and operating arrangements that let the operator open, close, move and hold it in position. It also requires communication between driver and operator when the monitor is used while the vehicle is moving, and marking of the designed maximum working pressure near the inlet.

For bracket assembly for removable equipment, the document requires retention against unintended movement, safe stowage, safe behavior after power loss, and force limits that make manual handling realistic for firefighters. For wheeled hosereels, the layout and forces are tightly controlled so that loading, unloading and removal can be done from ground level and by one firefighter where applicable.

For hook arm systems and demountables, the standard requires warnings, hold-to-run control, stable loading and unloading, visibility during the operation, audible warnings in the working area and a defined PL depending on whether the system is tipping or non-tipping. Annex B gives the calculation used to check stability, and Annex F gives examples of other demounting systems.

Extendable equipment and lifting systems

EN 1846-3:2026 requires a specific risk assessment for extendable equipment that can be deployed above ground level, plus visibility of the extremity from each operating position. If that cannot be achieved, the equipment needs protection against electric hazard.

If the lifting system is a loading crane, it has to comply with EN 12999. That makes the crane-related part of the vehicle system follow the established crane safety and performance rules instead of relying only on the vehicle standard.

What terms does EN 1846-3:2026 define?

  • Water installation - The set of components that collects, stores and delivers water or water-additive mixture at varying pressures and flow rates.
  • Additive installation - The set of components that collects, stores and delivers additive before it is mixed with water.
  • Monitor - A device for projecting extinguishing agents.
  • Bracket assembly for removable equipment - A mechanical system that helps load, unload and store equipment.
  • Demountable - A specially designed frame with superstructure that can be transported and mounted or dismounted by a demounting system.
  • Demounting system - Equipment installed on the vehicle and used to mount and dismount a demountable.
  • Hold-to-run control device - A control that keeps the machine moving only while the operator keeps the actuator pressed.
  • Required performance level (PL) - The performance level required for the safety-related parts of a control system.

Who uses EN 1846-3:2026?

EN 1846-3:2026 is used by manufacturers of firefighting and rescue service vehicles, by suppliers of pumps, monitors, foam systems, cranes and demounting equipment, and by integrators who install that equipment on the vehicle chassis. It is also used by test laboratories, certification bodies, inspectors and market surveillance authorities when checking safety and performance claims.

In practice, procurement teams and quality managers use it to specify what must be included in a tender or technical file. Maintenance providers and training organizations use it to understand operating limits, safety information and marking on the installed equipment.

What changed in EN 1846-3:2026 from the previous edition?

EN 1846-3:2026 replaces EN 1846-3:2013. The stated changes include an updated scope, revised and dated normative references, updated and added term entries, and moving symbols and abbreviated terms to Clause 4.

The foreword also states that the list of significant hazards is now in Annex A, required performance levels were added for the water installation, monitor, bracket assembly and hook arm system, ergonomics requirements were moved into the safety requirements, and the requirements for water and additive installation were updated. New material was added for lifting system using a crane, extendable equipment and Annex F, while Annex C, Annex E, marking requirements and Annex ZA were updated.

Which standards are used with EN 1846-3:2026?

EN 1846-3:2026 builds on several named standards that define the vehicle base, related equipment and safety methods.

  • EN 1846-1 - Gives the vehicle nomenclature and designation used by this part.
  • EN 1846-2 - Provides the common safety and performance requirements, general test conditions and vehicle-level requirements.
  • EN 1028-1 and EN 14710-1 - Define pump classifications and limits used for water installation performance.
  • EN 16327 - Applies to PPPS and CAFS when those additive systems are installed.
  • EN 12999 - Applies when the lifting system is a loading crane.
  • EN ISO 12100 - Provides the general risk assessment and risk reduction approach.
  • EN ISO 13849-1 and EN ISO 13849-2 - Set the control-system performance level and validation method.
  • EN ISO 4413 and EN ISO 4414 - Cover hydraulic and pneumatic fluid power safety.
  • EN 60529 - Defines IP protection degrees for outdoor instruments.
  • EN 659 and EN 547-2 - Support firefighter glove use and access opening dimensions.
  • prEN 15767-1 - Applies when a monitor assembly is also used as a portable monitor assembly.

What does the EN 1846-3:2026 document contain?

EN 1846-3:2026 contains verification clauses, worked test methods and annexes that support design, testing and documentation. It includes pressure, drainage, flushing, stability, visibility, force, rotation and performance checks for the covered equipment.

The document also contains a hazard list in Annex A, a stability calculation in Annex B, a tank-capacity method in Annex C, a monitor throw method in Annex D, a suction-height correction table in Annex E, and examples of other demounting systems in Annex F. These parts are the practical tools used to check whether the installed equipment meets the standard’s safety and performance expectations.

Relations

Effective Date
02-Oct-2024
Effective Date
11-Nov-2026
Effective Date
11-Nov-2026
Effective Date
11-Nov-2026
Effective Date
11-Nov-2026
Effective Date
11-Nov-2026
Effective Date
11-Nov-2026
Effective Date
11-Nov-2026
Effective Date
11-Nov-2026
Effective Date
11-Nov-2026
Effective Date
11-Nov-2026
Effective Date
11-Nov-2026
Effective Date
11-Nov-2026
Effective Date
11-Nov-2026
Effective Date
11-Nov-2026

Buy Documents

Standard

EN 1846-3:2026

English language (60 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

CIS Institut d.o.o.

Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

SA Slovenia Verified

Kiwa BDA Testing

Building and construction product certification.

RVA Netherlands Verified

Kmetijski inštitut Slovenije

Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

EN 1846-3:2026 is a standard published by the European Committee for Standardization (CEN). Its full title is "Firefighting and rescue service vehicles - Part 3: Permanently installed equipment - Safety and performance". This standard covers: 1.1 This document specifies the minimum requirements for safety and performance of some optional specific permanently installed equipment on firefighting and rescue service vehicles, operated by trained persons, as designated in EN 1846 1:2011 and specified in EN 1846 2:2024. NOTE 1 Categories and mass classes of these vehicles are given in EN 1846 1:2011. NOTE 2 Vehicle means ground vehicles which can also drive on rails and amphibious vehicles. The permanently installed equipment covered by this document is given below: - water installation; - additive installation; - monitor; - equipment gantries; - demounting systems. This document covers also the use of wireless control systems. NOTE 3 This document is assumed to be read in conjunction with any national regulations in force for vehicles using the public roads and with any EU Directives and associated EFTA regulations in force relevant to vehicles and their equipment. For the purposes of this document, the normal ambient temperature range is –15 °C to +40 °C. For equipment to be used at temperature outside this temperature range, the particular temperature range is specified by the user. A risk assessment determines any need for additional precautions. 1.2 This document does not deal with the following types of equipment: - all control systems outside of the cabin related to hook arm system; - provisions for non-firefighting removable equipment driven by PTO. 1.3 This document deals with the technical requirements to minimize the hazards listed in Annex A which can arise during operational use, routine checking and maintenance of firefighting and rescue service vehicles. It does not cover the hazards generated by: - non-permanently installed equipment i.e. portable equipment carried on the vehicle; - use in potentially explosive atmospheres; - commissioning and decommissioning; - noise (as permanently installed equipment cannot be operated separately from the vehicle, this hazard is covered in EN 1846 2:2024); - electromagnetic compatibility; - cyber security; - cyber safety. Additional measures not dealt with in this document can be necessary for specific use (e.g. fire in natural environment, flooding, etc.). 1.4 This document is not applicable to the equipment which is manufactured before its date of publication by CEN.

1.1 This document specifies the minimum requirements for safety and performance of some optional specific permanently installed equipment on firefighting and rescue service vehicles, operated by trained persons, as designated in EN 1846 1:2011 and specified in EN 1846 2:2024. NOTE 1 Categories and mass classes of these vehicles are given in EN 1846 1:2011. NOTE 2 Vehicle means ground vehicles which can also drive on rails and amphibious vehicles. The permanently installed equipment covered by this document is given below: - water installation; - additive installation; - monitor; - equipment gantries; - demounting systems. This document covers also the use of wireless control systems. NOTE 3 This document is assumed to be read in conjunction with any national regulations in force for vehicles using the public roads and with any EU Directives and associated EFTA regulations in force relevant to vehicles and their equipment. For the purposes of this document, the normal ambient temperature range is –15 °C to +40 °C. For equipment to be used at temperature outside this temperature range, the particular temperature range is specified by the user. A risk assessment determines any need for additional precautions. 1.2 This document does not deal with the following types of equipment: - all control systems outside of the cabin related to hook arm system; - provisions for non-firefighting removable equipment driven by PTO. 1.3 This document deals with the technical requirements to minimize the hazards listed in Annex A which can arise during operational use, routine checking and maintenance of firefighting and rescue service vehicles. It does not cover the hazards generated by: - non-permanently installed equipment i.e. portable equipment carried on the vehicle; - use in potentially explosive atmospheres; - commissioning and decommissioning; - noise (as permanently installed equipment cannot be operated separately from the vehicle, this hazard is covered in EN 1846 2:2024); - electromagnetic compatibility; - cyber security; - cyber safety. Additional measures not dealt with in this document can be necessary for specific use (e.g. fire in natural environment, flooding, etc.). 1.4 This document is not applicable to the equipment which is manufactured before its date of publication by CEN.

EN 1846-3:2026 is classified under the following ICS (International Classification for Standards) categories: 13.220.10 - Fire-fighting. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 1846-3:2026 has the following relationships with other standards: It is inter standard links to EN 1846-3:2013, EN 1846-2:2024, EN 12999:2020+A1:2025, EN 1028-1:2002+A1:2008, EN 14710-1:2005+A2:2008, EN 60529:1991/A1:2000, EN ISO 4414:2010, EN 16327:2014, EN 659:2003+A1:2008, EN ISO 12100:2010, EN ISO 4413:2010, EN 60529:1991/A2:2013, EN ISO 13849-1:2023, EN 15767-1:2026, EN 547-2:1996+A1:2008. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 1846-3:2026 is associated with the following European legislation: EU Directives/Regulations: 2023/1230; Standardization Mandates: M/605. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 1846-3:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 water installation
  • 3.1.1 classification of the water installation
  • 3.1.2 height
  • 3.1.3 standing surface of the vehicle
  • 3.1.4 standing surface of the operator
  • 3.1.5 installed water pump
  • 3.1.6 installed water tank
  • 3.1.7 supply and delivery connections for water
  • 3.1.8 pipework installation for water
  • 3.1.9 operating and control instruments for water
  • 3.1.10 hosereel
  • 3.1.11 wheeled hosereel
  • 3.2 additive
  • 3.2.1 additive installation
  • 3.2.2 installed additive pump
  • 3.2.3 installed additive tank
  • 3.2.4 supply and delivery connections for additive
  • 3.2.5 pipework installation for additive
  • 3.2.6 operating and control instruments for additive
  • 3.3 water tank capacity
  • 3.4 usable capacity
  • 3.5 mixing system
  • 3.6 monitor
  • 3.7 bracket assembly for removable equipment
  • 3.8 demountable
  • 3.9 demounting system
  • 3.10 hold-to-run control device
  • 4 Symbols and abbreviated terms
  • 5 Requirements and verifications
  • 5.1 General
  • 5.2 Safety requirements and/or protective/risk reduction measures — Verifications
  • 5.3 Performance requirements — Verifications
  • 6 Information for use
  • 6.1 General
  • 6.2 Essential information relevant to safety
  • 6.3 Information relevant to performance
  • 6.4 Marking on equipment
  • Annex A
  • 5.2.4 Monitor location /
  • 5.2.5 At the operating 4.1.2.3.3 of
  • 5.2.5 5.2.5
  • 5.2.5 At the operating 4.1.3.3 of
  • 5.2.5 position motion EN 1846-2:2024
  • 5.2.6.19 Crushing hazard Operator outside cabin / 5.2.6.11
  • 5.2.6.21 At the operating 4.1.2.3 and 4.1.2.5 of
  • 5.2.6.21 Line rupture hydraulic
  • 5.2.6.17 temperature parts EN 1846-2:2024
  • Annex B
  • Annex C
  • Annex D
  • Annex E
  • Annex F
  • Annex ZA
  • 5.2.6.13 1.1.6 (f) 5.2.5.10
  • 5.2.5 objects
  • 5.2.5.5 angles
  • 5.2.2.2 servicing points
  • 6.2 devices
  • 6.2 for use
  • 2.1 Machinery and related products for Not relevant
  • 2.2 Portable hand-held or hand-guided Not relevant
  • 3 Supplementary essential health and Not relevant
  • 3.3 Control systems Not relevant
  • 6 Supplementary essential health and Not relevant
  • 6.2 Control devices Not relevant
  • Bibliography

Introduction

This document is a type-C standard as stated in EN ISO 12100.

This document is of relevance, in particular, for the following stakeholder groups representing the market players with regard to machinery safety:

  • machine manufacturers (small, medium and large enterprises);
  • health and safety bodies (regulators, accident prevention organizations, market surveillance, etc.). Others can be affected by the level of machinery safety achieved with the means of the document by the above-mentioned stakeholder groups:
  • machine users/employers (small, medium and large enterprises);
  • machine users/employees (e.g. trade unions, organizations for people with special needs);
  • service providers, e.g. for maintenance (small, medium and large enterprises);
  • consumers (in the case of machinery intended for use by consumers). The above-mentioned stakeholder groups have been given the possibility to participate at the drafting process of this document.

The machinery concerned and the extent to which hazards, hazardous situations or hazardous events are covered are indicated in the Scope of this document.

When requirements of this type-C standard are different from those which are stated in type-A or type-B standards, the requirements of this type-C standard take precedence over the requirements of the other standards for machines that have been designed and built according to the requirements of this type-C standard.

While producing this document it was assumed that, due to the European regulations on the approval of vehicles for use on public roads, fire fighting vehicles still comply with:

  • EMC requirements;
  • cyber security requirements.

Therefore, EMC and cyber security are not further considered in this document.

SIST EN 1846-3:2026 EN 1846-3:2026 (E)

1 Scope

1.1 This document specifies the minimum requirements for safety and performance of some optional specific permanently installed equipment on firefighting and rescue service vehicles, operated by trained persons, as designated in EN 1846-1:2011 and specified in EN 1846-2:2024. NOTE 1 Categories and mass classes of these vehicles are given in EN 1846-1:2011. NOTE 2 Vehicle means ground vehicles which can also drive on rails and amphibious vehicles. The permanently installed equipment covered by this document is given below:

  • water installation;
  • additive installation;
  • monitor;
  • equipment gantries;
  • demounting systems.

This document covers also the use of wireless control systems. NOTE 3 This document is assumed to be read in conjunction with any national regulations in force for vehicles using the public roads and with any EU Directives and associated EFTA regulations in force relevant to vehicles and their equipment.

For the purposes of this document, the normal ambient temperature range is –15 °C to +40 °C. For equipment to be used at temperature outside this temperature range, the particular temperature range is specified by the user. A risk assessment determines any need for additional precautions. 1.2 This document does not deal with the following types of equipment:

  • all control systems outside of the cabin related to hook arm system;
  • provisions for non-firefighting removable equipment driven by PTO. 1.3 This document deals with the technical requirements to minimize the hazards listed in Annex A which can arise during operational use, routine checking and maintenance of firefighting and rescue service vehicles.

It does not cover the hazards generated by:

  • non-permanently installed equipment i.e. portable equipment carried on the vehicle;
  • use in potentially explosive atmospheres;
  • commissioning and decommissioning;
  • noise (as permanently installed equipment cannot be operated separately from the vehicle, this hazard is covered in EN 1846-2:2024);
  • electromagnetic compatibility;
  • cyber security;
  • cyber safety.

SIST EN 1846-3:2026 EN 1846-3:2026 (E) Additional measures not dealt with in this document can be necessary for specific use (e.g. fire in natural environment, flooding, etc.).

1.4 This document is not applicable to the equipment which is manufactured before its date of publication by CEN.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 547-2:1996+A1:2008, Safety of machinery — Human body measurements — Part 2: Principles for determining the dimensions required for access openings

EN 659:2003+A1:2008, Protective gloves for firefighters EN 1028-1:2002+A1:2008, Fire-fighting pumps — Fire-fighting centrifugal pumps with primer — Part 1:

Classification — General and safety requirements EN 1846-1:2011, Firefighting and rescue service vehicles — Part 1: Nomenclature and designation EN 1846-2:2024, Firefighting and rescue service vehicles — Part 2: Common requirements — Safety and performance EN 12999:2020+A1:2025, Cranes — Loader cranes EN 14710-1:2005+A2:2008, Fire-fighting pumps — Fire-fighting centrifugal pumps without primer — Part 1: Classification, general and safety requirements EN 15767-1:2026, Portable equipment for projecting extinguishing agents and firefighting support operations — Portable monitors — Part 1: General requirements for portable monitor assemblies EN 16327:2014, Fire-fighting — Positive-pressure proportioning systems (PPPS) and compressed-air foam systems (CAFS)

EN 60529:1991, Degrees of protection provided by enclosures (IP Code) (IEC 6059:1989) EN ISO 4413:2010, Hydraulic fluid power — General rules and safety requirements for systems and their components (ISO 4413:2010) EN ISO 4414:2010, Pneumatic fluid power — General rules and safety requirements for systems and their components (ISO 4414:2010) EN ISO 12100:2010, Safety of machinery — General principles for design — Risk assessment and risk reduction (ISO 12100:2010) EN ISO 13849-1:2023, Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design (ISO 13849-1:2023)

As impacted by EN 659:2003+A1:2008/AC:2009.

As impacted by EN 60529:1991/A1:2000 and EN 60529:1991/A2:2013, and EN 60529:1991/AC:2016-12, EN 60529:1991/corrigendum May 1993, and EN 60529:1991/A2:2013/AC:2019-02.

SIST EN 1846-3:2026 EN 1846-3:2026 (E)

3 Terms and definitions

For the purposes of this document, the terms and definitions given in EN 1846-1:2011, EN 1846-2:2024 and the following apply.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https://www.iso.org/obp/
  • IEC Electropedia: available at https://www.electropedia.org/

3.1 water installation

combination of components for the collection, storage and delivery of water and/or water-additive mixture at varying pressures and delivery rates

3.1.1 classification of the water installation

combination of the delivery rate Q specified at pressure p and at specified height d 1 a1

3.1.2 height

d difference of level between the standing surface of the vehicle and the water surface at the time of a pumping appliance suction operation

3.1.3 standing surface of the vehicle

surface on which the vehicle wheels are resting when it is operating

3.1.4 standing surface of the operator

surface on which the operator stands

3.1.5 installed water pump

pump for water permanently installed on a vehicle and driven by the power supply of the vehicle or by its own power supply

3.1.6 installed water tank

container for storage of water for fire service purposes

3.1.7 supply and delivery connections for water

inlet and outlet devices for joining hoses to the pipework installation

3.1.8 pipework installation for water

system linking the installed water pump(s), the installed water tank(s) and the supply and delivery connections

3.1.9 operating and control instruments for water

controls and gauges necessary to operate and monitor the water installation system

SIST EN 1846-3:2026 EN 1846-3:2026 (E)

3.1.10 hosereel

fixed hose storage system on a rotating drum for hose assembly(ies)

3.1.11 wheeled hosereel

hosereel designed for the storage, the transport and the deployment of layflat hose

3.2 additive

addition to water to enhance firefighting capabilities

3.2.1 additive installation

combination of components for the collection, storage and delivery of additive at varying pressures and delivery rates before mixing with water

3.2.2 installed additive pump

pump for additive permanently installed on a vehicle and driven by the power supply of the vehicle or by its own power supply

3.2.3 installed additive tank

container for storage of additive for fire service purposes

3.2.4 supply and delivery connections for additive

inlet and outlet devices for joining hoses to the additive installation

3.2.5 pipework installation for additive

system linking the installed additive pump(s), the installed additive tank(s) and the supply and delivery connections

3.2.6 operating and control instruments for additive

controls and gauges necessary to operate and monitor the additive installation system

3.3 water tank capacity

nominal capacity declared capacity of a tank

3.4 usable capacity

capacity of liquid contained in a tank that can be used by the corresponding pump(s)

3.5 mixing system

system to mix the additive (including foam concentrate) with water (and sometimes air) to produce the required firefighting media Note 1 to entry: The mixing system is part of the water and/or additive installation.

SIST EN 1846-3:2026 EN 1846-3:2026 (E)

3.6 monitor

device for projection of extinguishing agents

3.7 bracket assembly for removable equipment

bracket assembly mechanical system(s), manually or power driven, to assist with the loading, unloading and storage of equipment

3.8 demountable

specially designed frame with superstructure that can be transported by a suitable vehicle and mounted and dismounted by a demounting system

3.9 demounting system

equipment installed on the vehicle used to mount and dismount a demountable (3.8) from a vehicle Note 1 to entry: See examples in Figure 2, Figure 3 and Figures of Annex F.

3.10 hold-to-run control device

control device which initiates and maintains machine functions only as long as the manual control (actuator) is actuated [SOURCE: EN ISO 12100:2010, 3.28.3]

4 Symbols and abbreviated terms

The following symbols and abbreviated terms are used in this document:

d height, m d minimum effective throw of the monitor, m eff maximum throw of the monitor, m dmax H geodetic nominal suction height, m S geo N p maximum outlet pressure, bar a p pressure, bar a1 p maximum working pressure, bar a lim n maximum speed, rpm

Q flowrate of the monitor, l/min Q delivery rate of the water installation, l/min

FPN normal-pressure pump PL required performance level r

SIST EN 1846-3:2026 EN 1846-3:2026 (E)

5 Requirements and verifications

5.1 General

The general conditions for the tests to which this document refers are given in Annex A of EN 1846-2:2024.

Data of the component(s) may be used as part of the verification. Any permanently installed equipment shall not cause unintended interference to other permanently installed equipment on the vehicle.

Adjustments permitted during the intended use of the vehicle shall be possible without the use of tools. NOTE Tools means: screwdriver, hammer, etc.

Design and construction of permanently installed equipment shall comply with the requirements and specifications for installation on the chassis.

Verification By checking compliance with the chassis specification.

5.2 Safety requirements and/or protective/risk reduction measures — Verifications

5.2.1 General
5.2.1.1 Permanently installed equipment shall comply with the general safety requirements and/or

protective measures described in EN 1846-2:2024 as well as with the safety requirements and/or measures of 5.2. In addition, the equipment shall be designed according to the principles of EN ISO 12100:2010 for hazards relevant but not significant which are not dealt with in this document. 5.2.1.2 Each operating position for each item of equipment shall have a stop control. This stop control does not have to be an emergency stop control as specified in EN ISO 13850:2015. Verification By visual inspection and functional test of the stop control.

5.2.1.3 The design and selection of oil hydraulic components of permanently installed equipment

shall conform to the requirements of EN ISO 4413:2010.

Verification By inspection of the information supplied.

5.2.1.4 The design and selection of pneumatic components of permanently installed equipment shall

conform to the requirements of EN ISO 4414:2010.

Verification By inspection of the information supplied.

5.2.1.5 Construction techniques and materials of the permanently installed equipment shall be

chosen so that they are protected against corrosion.

SIST EN 1846-3:2026 EN 1846-3:2026 (E) Verification By verification of the attestation of the equipment/material’s supplier.

5.2.1.6 The equipment shall be protected against accumulation of water, dirt and corrosive

substances, between and within the construction elements. Particular care shall be taken to avoid electrochemical corrosion. Verification By visual inspection

5.2.1.7 The design of permanently installed equipment and their mountings shall withstand the

physical stresses applied in normal operational use.

Verification By visual inspection and functional verification after transportation tests. 5.2.1.8 Controls at the pump operating position shall include:

  • pump speed control device;
  • stop control (see 5.2.1.2).

Indicators visible from the pump operating position shall include:

  • pump pressure indicator for each nominal pressure according to 5.2.5.2 of EN 1028-1:2002+A1:2008;
  • pump vacuum indicator (where priming system fitted) according to 5.2.5.2 of EN 1028-1:2002+A1:2008;
  • critical vehicle malfunction warning device (e.g. oil pressure or water temperature);
  • level indication for each tank containing extinguishing liquids. Supplementary controls at the pump operating position can include, for example:
  • pump engaging device;
  • suction valve control;
  • priming device control;
  • delivery valve(s) control(s).

Supplementary indicators at the pump operating position can include, for example:

  • pump engaged indicator;
  • speed indicator of pump;
  • speed indicator of pump engine;
  • priming device engaged indicator;

SIST EN 1846-3:2026 EN 1846-3:2026 (E) - hour metre(s); - energy storage indicator.

If other operating position is provided, e.g. for monitor, controls and indicators shall be agreed at the time of enquiry and order.

Verification By visual and functional verification of controls and indicators except where the function of the component is outside normal operating use, in which case verification shall be by checking the wiring circuit.

The same method of verification should be applied to the optional indicators and/or controls, where used.

5.2.2 Water installation
5.2.2.1 General

5.2.2.1.1 The required performance level (PL ), in accordance with EN ISO 13849-1:2023, of the safety r related parts of the control system for regulation of the pressure and opening of pressure outlet(s) shall comply with PL a.

r Verification Documentation check.

5.2.2.1.2 All parts of the water installation designed to work at a pressure higher than 0,5 bar shall withstand the designed maximum working pressure (p ) specific to that part of the installation plus a lim 5,5 bar without any permanent deformation, damage or leakage.

Verification By hydrostatic test for 1 min. The pump may be excluded from this test. 5.2.2.1.3 The maximum outlet pressure p shall not exceed the limit pressure (p ) as defined in a a lim EN 1028-1:2002+A1:2008 or EN 14710-1:2005+A2:2008 at the maximum inlet pressure of the pump. Verification By calculation or dynamic test.

5.2.2.1.4 The maximum speed of the installed water pump shall be less than the maximum speed n as

defined in 3.6.3 of EN 1028-1:2002+A1:2008.

Verification By measuring the maximum speed of the pump.

5.2.2.1.5 The deviation of the outlet pressure of the pump shall meet the requirements of Table 1 when operating at p and Q .

a1 1.

SIST EN 1846-3:2026 EN 1846-3:2026 (E) Table 1 — Allowed pressure deviation Allowable pressure Pump Flowrate variation deviation Pump with Q < 3 000 l/min Q to 0,7 Q p to 1,25 p 1 1 1 a1 a1 Pump with Q ≥ 3 000 l/min Q to 0,85 Q p to 1,25 p 1 1 1 a1 a1 Verification By measuring the pressure deviations. During the test, manual adjustment of the speed of the pump shall not be allowed. The variation of flowrate shall be achieved within 3 s.

5.2.2.2 Water tank

Installations in water tanks (e.g. baffles) shall be designed in such a way that the inner walls of the water tank are accessible for maintenance (servicing, inspection, repair). Verification Visual verification.

In addition to compliance with the stability requirements given in EN 1846-2:2024, the design and mounting of the water tank and the location and the installation of baffles, if necessary, shall prevent any excessive dynamic force that can cause vehicle instability under anticipated operational conditions. NOTE Manufacturers have developed several different methods of designing machines which are stable under the conditions of intended use, and experience has shown that they can be equally effective. These can be based upon analytical computer software, physical testing, or designs which have been proven over several years of use. With the present state of knowledge, it is not possible to describe a single standardized method of design and of verification.

Verification By visual verification and attestation or documentation.

If personnel access holes are installed, the minimum clearance dimension shall be 450 mm and shall be accessible without removing major fixed components.

Verification By visual verification and measurement and by functional verification for access holes. A tank filling valve shall be fitted. A tank level indicator shall be visible at or near to the control position of the tank filling valve.

A single tank level indicator may be used if it is visible from both the control position of the tank filling valve and from the installed pump operating position.

Verification By visual verification

5.2.2.3 Access to supply and delivery connections for water or water with additive

5.2.2.3.1 The maximum height from the lowest point of the final supply and delivery connection(s) to the standing surface of the operator shall not exceed 1,5 m at unladen mass (see 3.1 of EN 1846-2:2024). Hosereel shall comply with requirements of 5.2.2.6.

SIST EN 1846-3:2026 EN 1846-3:2026 (E) Verification By visual verification and measurement.

5.2.2.3.2 The final supply and delivery connection(s) shall be angled downwards at an angle between 10° and 30° from the horizontal when they are higher than 0,5 m from the standing surface of the vehicle. If it is technically impossible to reach these angles, a device shall be provided to be inserted between the delivery or supply connection and the related hoses to achieve the required angle. It shall not be possible to connect hoses without this device.

Verification By measurement and functional test.

5.2.2.3.3 It shall be possible to relieve any pressure build up between the delivery connection and any blank cap fitted.

When hoses are stored in a locker in which the delivery connections are located, it shall not be possible to pressurize the hoses with the locker closed.

...