This document defines the rules for encoding the animal identification code in a specific memory bank known as MB 01 in the memory of an ISO 18000-63 transponder (UHF RFID technology).
- Standard14 pagesEnglish languagesale 15% off
This clause of Part 1 is replaced by the following.
This part of IEC 60335 deals with the safety of electric fence energizers, the rated voltage
of which is not more than 250 V and by means of which fence wires in agricultural, domestic
or feral animal control fences and security fences may be electrified or monitored.
NOTE 101 Examples of electric fence energizers coming within the scope of this standard are:
– mains-operated energizers;
– battery-operated electric fence energizers suitable for connection to the mains, as shown in Figure 101
and Figure 102;
– electric fence energizers operated by non-rechargeable batteries either incorporated or separate.
This standard does not in general take into account
– the use of appliances by young children or infirm persons without supervision;
– the playing with appliances by young children.
NOTE 102 Attention is drawn to the fact that
– for appliances intended to be used on board ships or aircraft, additional requirements can be necessary;
– in many countries, additional requirements are specified by the national health authorities, the national
authorities responsible for the protection of labour, the national water supply authorities and similar authorities.
NOTE 103 This standard does not apply to
– electromagnetically coupled animal trainer collars;
– appliances intended to be used in locations where special conditions prevail, such as the presence of a
corrosive or explosive atmosphere (dust, vapour or gas);
– separate battery chargers (IEC 60335-2-29);
– electric fishing machines (IEC 60335-2-86);
– electric animal-stunning equipment (IEC 60335-2-87);
– appliances for medical purposes (IEC 60601
- Standard63 pagesEnglish languagesale 10% offe-Library read for1 day
Applicable to the safety of electric fence energizers, the rated voltage of which is not more than 250 V.
- Amendment12 pagesEnglish languagesale 10% offe-Library read for1 day
Applicable to the safety of electric fence energizers, the rated voltage of which is not more than 250 V.
- Amendment12 pagesEnglish languagesale 10% offe-Library read for1 day
2019-08-2: PR=70278 (A11) covers common mods. to this EN
- Standard63 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60335-2-76:2018 RLV contains both the official IEC International Standard and its Redline version. The Redline version is not an official document, it is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60335-2-76:2018 deals with the safety of electric fence energizers, the rated voltage of which is not more than 250 V and by means of which fence wires in agricultural, domestic or feral animal control fences and security fences may be electrified or monitored. Examples of electric fence energizers coming within the scope of this standard are:
– mains-operated energizers;
– battery-operated electric fence energizers suitable for connection to the mains;
– electric fence energizers operated by non-rechargeable batteries either incorporated or separate.
This standard does not apply to:
– electromagnetically coupled animal trainer collars;
– appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
– separate battery chargers (IEC 60335-2-29);
– electric fishing machines (IEC 60335-2-86);
– electric animal-stunning equipment (IEC 60335-2-87);
– appliances for medical purposes (IEC 60601).
This Part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments. It was established on the basis of the fifth edition (2010) of that standard. This third edition cancels and replaces the second edition published in 2002, Amendment 1:2006 and Amendment 2:2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
– the text has been aligned with Edition 5.2 of Part 1;
– additional requirements for security fence energizers have been introduced (Clauses 3, 7, 19, 22, Figures and Annex BB);
– specific requirements for battery operated energizers have been moved to Annex S.
The contents of the corrigendum of November 2018 have been included in this copy.
- Standard60 pagesEnglish languagesale 15% off
- Standard124 pagesEnglish languagesale 15% off
- Standard123 pagesEnglish and French languagesale 15% off
2015-03-11: PR=24832 covering CMs to EN 60335-2-76:2005/FprA2:2013 merged in A2:2015 * FprAE (23101) also merged with 23990
- Amendment14 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 24631-1:2017 provides the means of evaluating the conformance with ISO 11784 and ISO 11785 of radiofrequency identification (RFID) transponders used in the individual identification of animals. It sets forth the conditions for the granting and use of the manufacturer code related to a transponder and the associated rights and obligations of the parties involved in the issuance of the code. The test procedures specified in this document are recognized by the Federation of European Companion Animals Veterinary Association (FECAVA) and World Small Animal Veterinarian Association (WSAVA) and, as such, can be applied also to companion animals.
- Standard15 pagesEnglish languagesale 15% off
- Standard15 pagesEnglish languagesale 15% off
- Standard15 pagesFrench languagesale 15% off
- Standard15 pagesFrench languagesale 15% off
ISO 24631-3:2017 provides the means of evaluating the performance of ISO 11784- and ISO 11785-conformant radiofrequency identification (RFID) transponders used in the individual identification of animals. The test procedures specified in this document are recognized by the Federation of European Companion Animals Veterinary Association (FECAVA) and World Small Animal Veterinarian Association (WSAVA) and as such can be applied also to companion animals.
- Standard28 pagesEnglish languagesale 15% off
- Standard28 pagesEnglish languagesale 15% off
- Standard29 pagesFrench languagesale 15% off
- Standard29 pagesFrench languagesale 15% off
ISO 24631-4:2017 provides the means of evaluating the performance of ISO 11784- and ISO 11785-conformant RFID (radiofrequency identification) transceivers used in the individual identification of animals. The test procedures specified in this document are recognized by the Federation of European Companion Animals Veterinary Association (FECAVA) and World Small Animal Veterinarian Association (WSAVA) and, as such, can be applied also to companion animals.
- Standard15 pagesEnglish languagesale 15% off
- Standard15 pagesFrench languagesale 15% off
ISO 24631-2:2017 provides the means of evaluating the conformance with ISO 11784 and ISO 11785 of radiofrequency identification (RFID) transceivers used in the individual identification of animals. It also specifies the procedure for applying for a transceiver test registration and the associated rights and obligations of the parties involved. ISO 24631-2:2017 includes a wireless synchronization test applicable to mobile transceivers; however, it contains no provision for evaluating the wired synchronization of stationary transceivers. The test procedures specified in this document are recognized by the Federation of European Companion Animals Veterinary Association (FECAVA) and World Small Animal Veterinarian Association (WSAVA) and, as such, can be applied also to companion animals.
- Standard12 pagesEnglish languagesale 15% off
- Standard13 pagesFrench languagesale 15% off
ISO 24631-5:2014 specifies rules and procedures for verifying the capability of RFID transceivers of reading transponders used in individual animal identification complying to ISO 11784 and ISO 11785. In addition, ISO 24631-5:2014 specifies how to apply for an approval and the rights and duties to use this approval. ISO 24631-5:2014 does not set out the procedures for evaluating wireless synchronised mobile transceivers and also this document contains no provision for evaluating wired synchronisation of stationary transceivers. This test differs from ISO 24631‑2, which is intended for testing transceivers with all mandatory features described in ISO 11784 and ISO 11785. The test described here is intended for cost-effective non-synchronising transceivers that are capable of reading transponders complying to ISO 11784 and ISO 11785 but have no synchronisation capability and does not have to support the dual adaptive protocol. Furthermore, the activation field frequency accuracy is more relaxed.
- Standard11 pagesEnglish languagesale 15% off
- Standard10 pagesFrench languagesale 15% off
This International Standard deals with the safety of electric fence energizers, the rated voltage of which is not more than 250 V and by means of which fence wires in agricultural, domestic or feral animal control fences and security fences may be electrified or monitored.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard10 pagesEnglish and French languagesale 15% off
- Standard20 pagesEnglish and French languagesale 15% off
ISO 24631-7:2012 specifies rules and procedures for synchronizing RFID transceivers while reading transponders used in individual animal identification complying to ISO 11784 and ISO 11785. The synchronization scheme described herein may be fully implemented within each reader, and such readers when attached to the synchronization bus create a peer-to-peer network (all readers are equal ? there is no dedicated master). Additionally, a cluster of readers, which could be in a master/slave configuration, may also be added to the bus using a dedicated, manufacturer specific Synchronization Interface. The Synchronization Interface presents to the synchronization bus electrical characteristics identical to those of a single peer-to-peer reader. The transceiver conformance standard ISO 24631-2 permits activation on/off timing tolerances of −0/+1 ms and therefore gives reader manufacturers options as to their preferred method for detecting the HDX header; partial or full. However, when synchronizing readers, irrespective of which header detection method is used, it is critical that all readers adhere strictly to the specific timings and timing tolerances as given in the timing diagrams. Particular attention should also be given to fault diagnostics which becomes more important when a reader network comprises products from different manufacturers. The obvious case is where a reader which is part of a network has become detached e.g. sync cable break, and it considers it's self to be now standalone and thus permitted to operate asynchronously to the detriment of all other readers.
- Standard17 pagesEnglish languagesale 15% off
- Standard16 pagesFrench languagesale 15% off
ISO 24631-6:2011 specifies the representation of the animal identification information specified in ISO 11784 and ISO 11785 on a transceiver display and its communication from transceivers to systems in which the information may be stored in a database, used for process control or displayed.
- Standard6 pagesEnglish languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
To be implemented in all countries with exception of CH * See D129/130 (new implementation dates) and D129/131 (not to be published before 2008-01-01)
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
Incorporates EN 60335-2-76:2005/prAA (pr=16650)
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
Applicable to the safety of electric fence energizers, the rated voltage of which is not more than 250 V.
- Standard48 pagesEnglish languagesale 10% offe-Library read for1 day
Applicable to the safety of electric fence energizers, the rated voltage of which is not more than 250 V. The contents of the corrigendum of August 2013 have been included in this copy.
- Standard43 pagesEnglish languagesale 15% off
- Standard91 pagesEnglish and French languagesale 15% off
- Standard91 pagesEnglish and French languagesale 15% off
- Standard92 pagesEnglish and French languagesale 15% off
- Standard7 pagesEnglish and French languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
Deals with the safety of electric fence energizers for agricultural, feral animal control and security fences. This includes mains-operated and battery-operated energizers.
- Standard63 pagesEnglish and French languagesale 15% off
- Standard69 pagesEnglish and French languagesale 15% off
- Standard15 pagesEnglish and French languagesale 15% off
- Standard13 pagesEnglish languagesale 15% off
- Standard14 pagesFrench languagesale 15% off
- Standard14 pagesFrench languagesale 15% off
Contains the structure of the radio-frequency identification code for animals. Does not specify the characteristics of the transmission protocols between transponder and transceiver. Replaces the first edition.
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Draft10 pagesEnglish languagesale 10% offe-Library read for1 day
NWI requested to 141 BT (March 21, 2012) * Enquiries for prAE (PR=23101), prAF (PR=24113) and prAG (PR=24114) circulated together with same limit dates for comments * 2013-09-25: FV allocated to cpalagi@cencenelec.eu * prAG (PR=24114) merged into prAE * 24832+23101 have been integrated in 23990 and published as EN 60335-2-76:2005/A2:2015
- Draft5 pagesEnglish languagesale 10% offe-Library read for1 day
2014-11-19: Further to the negative vote, CLC/TC 61 decided at its meeting held on 2014-05-26/28 to stop this project.
- Draft4 pagesEnglish languagesale 10% offe-Library read for1 day
Work incorporated into PR=16649
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
D142/C058: NWI approved * Enquiries for prAE (PR=23101), prAF (PR=24113) and prAG (PR=24114) circulated together with same limit dates for comments * 2013-09-25 decision: prAG merged into prAE (PR=23101)
- Draft3 pagesEnglish languagesale 10% offe-Library read for1 day
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60335 deals with the safety of electric fence energizers, the rated voltage of which is not more than 250 V and by means of which fence wires in agricultural, domestic or feral animal control fences and security fences may be electrified or monitored. NOTE 101 Examples of electric fence energizers coming within the scope of this standard are: - mains-operated energizers; - battery-operated electric fence energizers suitable for connection to the mains, as shown in Figure 101 and Figure 102; - electric fence energizers operated by non-rechargeable batteries either incorporated or separate. This standard does not in general take into account - the use of appliances by young children or infirm persons without supervision; - the playing with appliances by young children. NOTE 102 Attention is drawn to the fact that - for appliances intended to be used on board ships or aircraft, additional requirements can be necessary; - in many countries, additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour, the national water supply authorities and similar authorities. NOTE 103 This standard does not apply to - electromagnetically coupled animal trainer collars; - appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas); - separate battery chargers (IEC 60335-2-29); - electric fishing machines (IEC 60335-2-86); - electric animal-stunning equipment (IEC 60335-2-87); - appliances for medical purposes (IEC 60601)
- Standard63 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 24631-3:2009 provides the means of evaluating the performance of ISO 11784- and ISO 11785‑conformant RFID (radiofrequency identification) transponders used in the individual identification of animals.
- Standard28 pagesEnglish languagesale 15% off
- Standard29 pagesFrench languagesale 15% off
ISO 24631-2:2009 provides the means of evaluating the conformance with ISO 11784 and ISO 11785 of RFID (radiofrequency identification) transceivers used in the individual identification of animals. It also specifies the procedure for applying for a transceiver test approval and the associated rights and obligations of the parties involved. ISO 24631:2009 includes a wireless synchronization test applicable to mobile transceivers; it contains no provision however for evaluating the wired synchronization of stationary transceivers.
- Standard12 pagesEnglish languagesale 15% off
- Standard13 pagesFrench languagesale 15% off
ISO 24631-4:2009 provides the means of evaluating the performance of ISO 11784- and ISO 11785‑conformant RFID (radiofrequency identification) transceivers used in the individual identification of animals.
- Standard15 pagesEnglish languagesale 15% off
- Standard15 pagesFrench languagesale 15% off
ISO 24631-1:2009 provides the means of evaluating the conformance with ISO 11784 and ISO 11785 of RFID (radiofrequency identification) transponders used in the individual identification of animals. It sets forth the conditions for the granting and use of the manufacturer code related to a transponder and the associated rights and obligations of the parties involved in the issuance of the code.
- Standard13 pagesEnglish languagesale 15% off
- Standard14 pagesFrench languagesale 15% off
Superseded by EN 60335-2-76:2005
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment11 pagesEnglish languagesale 10% offe-Library read for1 day
Deals with the safety of electric fence energizers for agricultural, feral animal control and security fences. This includes mains-operated and battery-operated energizers.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day