IEC 61083-3:2020 is applicable to digital recording instruments used for measurements during tests with high alternating and direct voltages and currents. It specifies the measuring characteristics and calibrations required to meet the measuring uncertainties and procedures specified in the relevant IEC standards (e.g. IEC 60060-1, IEC 60060-2, IEC 60060-3, IEC 62475, IEC 61180).
This document is applicable to those digital recording instruments that will be designed and type tested according t...
view more

    • sale 15% off
    • Standard
      66 pages
      English and French language

IEC 60112:2020 specifies the method of test for the determination of the proof and comparative tracking indices of solid insulating materials on pieces taken from parts of equipment and on plaques of material using alternating voltage. This document provides a procedure for the determination of erosion when required.
This test method evaluates the composition of the material as well as the surface of the material being evaluated. Both the composition and surface condition directly influence t...
view more

    • sale 15% off
    • Standard
      45 pages
      English and French language

IEC 61788-26:2020 specifies a test method for determining the DC critical current of short RE (rare earth)-Ba-Cu-O (REBCO) composite superconductor specimens that have a shape of straight flat tape. This document applies to test specimens shorter than 300 mm and having a rectangular cross section with an area of 0,03 mm2 to 7,2 mm2, which corresponds to tapes with width ranging from 1,0 mm to 12,0 mm and thickness from 0,03 mm to 0,6 mm.
This method is intended for use with superconductor speci...
view more

    • sale 15% off
    • Standard
      54 pages
      English and French language

EN-IEC 61010-2-010 specifies particular safety requirements for the following types a) to c) of electrical equipment and their accessories, wherever they are intended to be used, whenever the heating of materials is one of the functions of the equipment. Addition: Add the following text after item c): It is possible that all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this standard. In that case, the requiremen...view more

    • sale 10% off
    • Standard
      30 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      23 pages
      English language
    • e-Library read for
      1 day

EN-IEC 61010-2-081 applies to automatic and semi-automatic laboratory equipment for analysis and other purposes. Automatic and semi-automatic laboratory equipment consists of instruments or systems for measuring or modifying one or more characteristics or parameters of samples, performing the complete process or parts of the process without manual intervention. Equipment forming part of such a system is within the scope of this document. Examples of equipment within the scope of this document in...view more

    • sale 10% off
    • Standard
      16 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      12 pages
      English language
    • e-Library read for
      1 day

IEC 61010-2-040:2020 is available as IEC 61010-2-040:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61010-2-040:2020 specifies safety requirements for electrical equipment intended for sterilization, washing, and disinfection of medical materials in the medical, veterinary, pharmaceutical and laboratory fields, when used under the environmental conditions of 1.4. Examples of such equip...
view more

    • sale 15% off
    • Standard
      74 pages
      English and French language

IEC 61010-2-033:2019 is available as IEC 61010-2-033:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61010-2-033:2019 specifies safety requirements for hand-held multimeters for domestic and professional use, capable of measuring mains. Hand-held multimeters are multi-range multifunction measuring instruments intended to measure voltage and other electrical quantities such as resistance...
view more

    • sale 15% off
    • Standard
      86 pages
      English and French language

IEC 61010-2-032:2019 is available as IEC 61010-2-032:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61010-2-032:2019 specifies safety requirements for hand-held and hand-manipulated current sensors described below. These current sensors are for measuring, detecting or injecting current, or indicating current waveforms on circuits without physically opening the current path of the circ...
view more

    • sale 15% off
    • Standard
      124 pages
      English and French language

IEC 61010-1:2010 specifies general safety requirements for the following types of electrical equipment and their accessories, wherever they are intended to be used.
a) Electrical test and measurement equipment
b) Electrical industrial process-control equipment
c) Electrical laboratory equipment
This third edition cancels and replaces the second edition published in 2001. It constitutes a technical revision. This edition includes the following significant changes from the second edition, as we...
view more

    • sale 10% off
    • Corrigendum
      4 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60746 is intended:
• to specify terminology, definitions and requirements for statements by manufacturers for
analyzers, sensor units and electronic units used for the determination of dissolved
oxygen partial pressure or concentration;
• to establish performance tests for such analyzers, sensor units and electronic units;
• to provide basic documents to support the applications of quality assurance standards
[1]1.
This document applies to analyzers using membrane covered...
view more

    • sale 10% off
    • Standard
      28 pages
      English language
    • e-Library read for
      1 day

2019-01-21 JF  Under publication. To be published by 2019-03-08.
2018-12-20 JF: the Common modification (PR=68281) received positive assessment. This project is to be published as amendment with Common modification.
2018-10-11 JF the project TO BE PUT ON HOLD until the Common Modification (PR=68281) are finalised
2018-10-09 JF: assessment of the second formal vote draft is missing
2017-09-20 - D158/C013 - BT drop + vote & request 2nd vote

    • sale 10% off
    • Amendment
      37 pages
      English language
    • e-Library read for
      1 day

IEC 61010-1:2010 specifies general safety requirements for the following types of electrical equipment and their accessories, wherever they are intended to be used. a) Electrical test and measurement equipment b) Electrical industrial process-control equipment c) Electrical laboratory equipment This third edition cancels and replaces the second edition published in 2001. It constitutes a technical revision. This edition includes the following significant changes from the second edition, as well ...view more

    • sale 10% off
    • Corrigendum
      4 pages
      English language
    • e-Library read for
      1 day

IEC 61010-2-012:2019 is available as IEC 61010-2-012:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61010-2-012:2019 specifies safety requirements for electrical equipment and its accessories within the categories a) through c), wherever it is intended to be used, whenever that equipment incorporates one or more of the following characteristics:
– A refrigerating system that is acted ...
view more

    • sale 15% off
    • Standard
      177 pages
      English and French language

IEC 61010-2-011:2019 is available as IEC 61010-2-011:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61010-2-011:2019 specifies particular safety requirements for the following types a) to c) of electrical equipment and their accessories, wherever they are intended to be used, whenever that equipment incorporates refrigerating systems as an integral part of, or separate from, the equi...
view more

    • sale 15% off
    • Standard
      103 pages
      English and French language

IEC TS 62271-304:2019 applies to indoor enclosed switchgear and controlgear complying with IEC 62271-200 and IEC 62271-201, intended to be used in special service conditions with respect to condensation and pollution deviating from the normal service conditions specified in IEC 62271-1.
The test detailed in this document has been designed primarily to classify the electrical insulation performance of equipment having high-voltage electrical insulation exposed to indoor service conditions, m...
view more

    • sale 15% off
    • Technical specification
      54 pages
      English and French language

This part of IEC 60746 is intended: - to specify terminology, definitions and requirements for statements by manufacturers for analyzers, sensor units and electronic units used for the determination of dissolved oxygen partial pressure or concentration; - to establish performance tests for such analyzers, sensor units and electronic units; - to provide basic documents to support the applications of quality assurance standards [1]1. This document applies to analyzers using membrane covered ampero...view more

    • sale 10% off
    • Standard
      28 pages
      English language
    • e-Library read for
      1 day

2019-01-21 JF  Under publication. To be published by 2019-03-08.
2018-12-20 JF: the Common modification (PR=68281) received positive assessment. This project is to be published as amendment with Common modification.
2018-10-11 JF the project TO BE PUT ON HOLD until the Common Modification (PR=68281) are finalised
2018-10-09 JF: assessment of the second formal vote draft is missing
2017-09-20 - D158/C013 - BT drop + vote & request 2nd vote

    • sale 10% off
    • Amendment
      37 pages
      English language
    • e-Library read for
      1 day

IEC 61010-2-091:2019 is available as IEC 61010-2-091:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61010-2-091:2019 specifies particular safety requirements for cabinet X-ray systems, which fall under any of categories a), b) or c) below.
a) Electrical test and measurement equipment
This is equipment which by electromagnetic means tests, measures, indicates or records one or more...
view more

    • sale 15% off
    • Standard
      57 pages
      English and French language

IEC 61010-2-081:2019 is available as IEC 61010-2-081:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61010-2-081:2019 applies to automatic and semi-automatic laboratory equipment for analysis and other purposes. Automatic and semi-automatic laboratory equipment consists of instruments or systems for measuring or modifying one or more characteristics or parameters of samples, performin...
view more

    • sale 15% off
    • Standard
      21 pages
      English and French language

IEC 61010-2-010:2019 is available as IEC 61010-2-010:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61010-2-010:2019 specifies particular safety requirements for the following types a) to c) of electrical equipment and their accessories, wherever they are intended to be used, whenever the heating of materials is one of the functions of the equipment.
a) Electrical test and measureme...
view more

    • sale 15% off
    • Standard
      50 pages
      English and French language