SC 8 - Volume measuring instruments
- Abstract
Standardization of devices for laboratory purposes including apparatus, instruments and associated supplies which are used to measure volume, with respect to operational and measurement principles, materials of construction, performance, dimensions, marking, testing, as well as the terms and definitions used in connection therewith.
- Slovenian
Instruments de mesure du volume
Standardization of devices for laboratory purposes including apparatus, instruments and associated supplies which are used to measure volume, with respect to operational and measurement principles, materials of construction, performance, dimensions, marking, testing, as well as the terms and definitions used in connection therewith.
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
This document describes the measurement uncertainty analysis of the measurement procedures described in ISO 23783-2, following the approach described in ISO/IEC Guide 98-3. This document also includes the determination of other uncertainty components related to the liquid delivery process and the device under test (DUT) to estimate the overall measurement uncertainty of delivered volumes by an automated liquid handling system (ALHS).
- Technical report43 pagesEnglish languagesale 15% off
This document provides user guidance regarding the selection of piston-operated volumetric apparatus (POVA) (including exchangeable parts) and best practices for their use. This document also specifies requirements for user training and competence. Further, this document introduces performance tolerances and testing of POVA to ensure fitness for their intended use.
- Standard23 pagesEnglish languagesale 15% off
- Standard26 pagesFrench languagesale 15% off
This document gives detailed information regarding the evaluation of uncertainty for the photometric reference measurement procedure specified in ISO 8655-8 and the photometric procedure specified in ISO 8655-7:2022, Annex B according to ISO/IEC Guide 98-3. This document also describes the determination of other uncertainty components related to the liquid delivery process of a piston-operated volumetric apparatus (POVA), e.g. repeatability and handling. Furthermore, it provides examples for the calculation and application of the uncertainty of the mean delivered volume and the uncertainty in use of a single delivered volume.
- Technical report24 pagesEnglish languagesale 15% off
- Technical report26 pagesFrench languagesale 15% off
This document gives detailed information regarding the evaluation of uncertainty for the gravimetric reference measurement procedure specified in ISO 8655-6[1] and the gravimetric procedure specified in ISO 8655-7:2022[1], Annex A, according to the ISO/IEC Guide 98-3[16]. This document also includes the determination of other uncertainty components related to the liquid delivery process of a piston-operated volumetric apparatus (POVA), e.g. repeatability and handling. Furthermore, it provides examples for the calculation and application of the uncertainty of the mean delivered volume and the uncertainty in use of a single delivered volume.
- Technical report18 pagesEnglish languagesale 15% off
- Technical report19 pagesFrench languagesale 15% off
This document specifies procedures for the determination of volumetric performance of automated liquid handling systems (ALHS), including traceability and estimations of measurement uncertainty of measurement results. This document is applicable to all ALHS with complete, installed liquid handling devices, including tips and other essential parts needed for delivering a specified volume, which perform liquid handling tasks without human intervention into labware. NOTE For terminology and general requirements of automated liquid handling systems, see ISO 23783-1. Determination, specification, and reporting of volumetric performance of automated liquid handling systems is described in ISO 23783-3.
- Standard77 pagesEnglish languagesale 15% off
- Standard81 pagesFrench languagesale 15% off
This document defines terms relating to automated liquid handling systems (ALHS). This document also specifies general requirements for the use of ALHS. It describes types of ALHS and specific use requirements, settings, and adjustments for each ALHS type. It also specifies environmental requirements for the use of ALHS. This document is applicable to all ALHS with complete, installed liquid handling devices, including tips and other essential parts needed for delivering a specified volume, which perform liquid handling tasks without human intervention into labware. NOTE Measurement procedures for the determination of volumetric performance are given in ISO 23783-2. The determination, specification, and reporting of volumetric performance of automated liquid handling systems are described in ISO 23783-3.
- Standard19 pagesEnglish languagesale 15% off
- Standard22 pagesFrench languagesale 15% off
This document provides guidance and establishes requirements for collecting and examining volumetric performance data of automated liquid handling systems (ALHS). It specifies how to index and track volumetric performance data and provides descriptive statistics for the evaluation of these data. This document also specifies reporting requirements of ALHS volumetric performance. This document is applicable to all ALHS with complete, installed liquid handling devices, including tips and other essential parts needed for delivering a specified volume, which perform liquid handling tasks without human intervention into labware. NOTE For terminology and general requirements of automated liquid handling systems, see ISO 23783-1. Measurement procedures for the determination of volumetric performance are given in ISO 23783-2.
- Standard21 pagesEnglish languagesale 15% off
- Standard21 pagesFrench languagesale 15% off
This document sets out requirements for the construction of general laboratory volumetric flasks made of plastic material.
- Standard11 pagesEnglish languagesale 15% off
This document specifies the photometric reference measurement procedure for the determination of volume of piston-operated volumetric apparatus (POVA). The procedure is applicable to complete systems comprising the basic apparatus with a maximum nominal volume of 5 000 µl and all parts selected for use with the apparatus, disposable or reusable, involved in the measurement by delivery (Ex).
- Standard18 pagesEnglish languagesale 15% off
- Standard20 pagesFrench languagesale 15% off
This document specifies — metrological requirements, — maximum permissible errors, — requirements for marking and — information to be provided for users, for air-displacement (type A) and positive displacement (type D) single-channel and multi-channel pipettes, complete with their selected tip(s) and any other essential, consumable parts, designed to deliver the selected volume (Ex).
- Standard15 pagesEnglish languagesale 15% off
- Standard15 pagesFrench languagesale 15% off
This document specifies — metrological requirements, — maximum permissible errors, — requirements for marking and — information to be provided for users, for burettes. This document is applicable to burettes with nominal volumes up to 100 ml, designed to deliver their specified volume (Ex).
- Standard6 pagesEnglish languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
This document specifies a gravimetric reference measurement procedure for the determination of volume of piston-operated volumetric apparatus (POVA). The procedure is applicable to complete systems comprising the basic apparatus and all parts selected for use with the apparatus, disposable or reusable, involved in the measurement by delivery (Ex) or contained (In).
- Standard16 pagesEnglish languagesale 15% off
- Standard18 pagesFrench languagesale 15% off
This document specifies general requirements for piston-operated volumetric apparatus (POVA). It is applicable to pipettes, burettes, dilutors, dispensers and manually operated precision laboratory syringes. It furthermore defines terms for the use of piston-operated volumetric apparatus and gives user recommendations. This document does not apply to medical products intended for use on humans, e.g. for medical syringes.
- Standard11 pagesEnglish languagesale 15% off
- Standard12 pagesFrench languagesale 15% off
This document specifies — metrological requirements, — maximum permissible errors, — requirements for marking and — information to be provided for users, for dispensers. It is applicable to dispensers with nominal volumes from 1 μl up to 200 ml, designed to deliver their volume (Ex).
- Standard8 pagesEnglish languagesale 15% off
- Standard8 pagesFrench languagesale 15% off
This document specifies — metrological requirements, — maximum permissible errors, — requirements for marking and — information to be provided for users, for dilutors with a sample uptake capacity (In) from 5 μl to 1 ml and a diluent capacity (Ex) from 50 μl to 100 ml. They are designed to deliver the sample and diluent together in measured proportion and measured volume.
- Standard6 pagesEnglish languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
This document specifies — metrological requirements, — maximum permissible errors, — requirements for marking and — information to be provided for users, for manually operated precision laboratory syringes made of glass or glass and metal designed to deliver their selected volume (Ex). Manually operated precision laboratory syringes are instruments used for delivering liquids and gases. The barrel is typically made of glass and the plunger and the needle are typically made of metal.
- Standard7 pagesEnglish languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
This document specifies alternative measurement procedures for the determination of volume of piston-operated volumetric apparatus. The procedures are applicable to complete systems comprising the basic apparatus and all parts selected for use with the apparatus, disposable or reusable, involved in the measurement by delivery process (Ex). Methods described in this document are suitable for various maximum nominal volumes of piston-operated volumetric apparatus. It is the responsibility of the user to select the appropriate method.
- Standard48 pagesEnglish languagesale 15% off
- Standard50 pagesFrench languagesale 15% off
This document provides methods for the testing, calibration and use of volumetric instruments made from glass and plastic in order to obtain the best accuracy in use. NOTE Testing is the process by which the conformity of the individual volumetric instrument with the appropriate standard is determined, resulting in the determination of its error of measurement at one or more points. This document is applicable to volumetric instruments with nominal capacities in the range of 100 µl to 10 000 ml. These include single-volume pipettes (see ISO 648), graduated pipettes (see ISO 835), burettes (see ISO 385), volumetric flasks (see ISO 1042 and ISO 5215), and graduated measuring cylinders (see ISO 4788 and ISO 6706). The methods are not intended for testing of volumetric instruments with capacities below 100 µl such as micro-glassware. This document does not deal specifically with pycnometers as specified in ISO 3507. However, the procedures specified for the determination of volume of glassware can, for the most part, also be followed for the determination of a pycnometer volume. For some types of pycnometers, special handling can be necessary.
- Standard21 pagesEnglish languagesale 15% off
- Standard22 pagesFrench languagesale 15% off
ISO 384:2015 sets out principles for the design of volumetric instruments manufactured from glass or from plastics in order to facilitate the most reliable and convenient use to the intended degree of accuracy.
- Standard15 pagesEnglish languagesale 15% off
- Standard15 pagesFrench languagesale 15% off
ISO 13079:2011 specifies requirements for single-use and re-usable glass and plastics tubes for measuring the erythrocyte sedimentation rate (ESR) by the Westergren method, and for a support to hold tubes during the performance of the test. These so-called "Westergren tubes" are also sometimes designated as "Westergren pipettes". A procedure for measuring the erythrocyte sedimentation rate by the Westergren method is given in an informative annex. ISO 13079:2011 does not apply to single-use containers for human venous blood specimen collection and their accessories for which other standards apply. It also does not apply for devices where the Westergren method has been used as basis to develop other, similar methods or equipment for the erythrocyte sedimentation rate determination.
- Standard15 pagesEnglish languagesale 15% off
- Standard15 pagesFrench languagesale 15% off
- Standard18 pagesRussian languagesale 15% off
ISO 648:2008 specifies metrological and constructional requirements for volumetric pipettes with one mark (total delivery) and for volumetric pipettes with two marks, both of which are adequate for general laboratory purposes. The details specified are in conformity with the principles of design and construction of volumetric glassware given in ISO 384.
- Standard8 pagesEnglish languagesale 15% off
- Standard8 pagesFrench languagesale 15% off
ISO 835:2007 specifies metrological and constructional requirements for graduated pipettes, adequate for general laboratory purposes.
- Standard12 pagesEnglish languagesale 15% off
- Standard13 pagesFrench languagesale 15% off
- Standard12 pagesArabic languagesale 15% off
ISO 4788:2005 specifies dimensions, material and constructional and metrological requirements of graduated measuring cylinders of tall form (Type 1a and Type 1b) and of squat form (Type 2). All types are suitable for general laboratory use. The specifications in ISO 4788:2005 are in conformity with the principles of design and construction of volumetric glassware given in ISO 384.
- Standard6 pagesEnglish languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
This International Standard provides metrological and construction requirements for an internationally acceptable series of burettes, suitable for general laboratory purposes. The details specified are in accordance with the principles of design and construction of volumetric glassware given in ISO 384. For piston burettes, see ISO 8655-3.
- Standard12 pagesEnglish languagesale 15% off
- Standard12 pagesFrench languagesale 15% off
This International Standard specifies requirements for a series of pyknometers for general laboratory use for the determination of the densities of liquids. Specialized pyknometers for use with particular products, or otherwise not in common use, are excluded. Sufficient details to define such pyknometers should be included in International Standards which specify or describe their use. A device suitable for adjustment of the liquid level in the neck of the Reischauer pyknometer is shown in annex A.
- Standard14 pagesEnglish languagee-Library read for
- Standard14 pagesEnglish languagesale 15% off
- Standard7 pagesEnglish languagee-Library read for
- Standard7 pagesEnglish languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
- Standard6 pagesEnglish languagee-Library read for
- Standard6 pagesEnglish languagesale 15% off
Flow-out and blow-out pipettes are considered. They will only be expected to provide their specified performance during the original operation. The requirements deal with the basis of adjustment, dimensions, delivery time and construction. The determination of accuracy and repeatability and the marking are specified.
- Standard6 pagesEnglish languagee-Library read for
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
Two types are specified: type I with graduation line and colour code which contains its volume when filled to the graduation line from the end away from the colour code, type II without markings wjich contains its volume when filled completely. Construction are shown in figures, the dimensions are tabled. The definition of capacity of each type is given and the determination of accuracy and repeatability is specified.
- Standard7 pagesEnglish languagee-Library read for
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
The requirements specify a series of plastic cylinders having a graduated volumetric scale and a pouring spout. The series of nominal capacities is tabled and so do the dimesions. The construction is illustrated by some figures showing the general appearance and the scales of measuring cylinders. The annex deal with testing of plastic cylinders, test for ionic material extracted by water and with the flexibility and recovery test.
- Standard11 pagesEnglish languagee-Library read for
- Standard9 pagesEnglish languagesale 15% off
- Standard9 pagesFrench languagesale 15% off
- Standard9 pagesFrench languagesale 15% off
Three different types of glass instruments for the accurate determination of the ethanol content of simple mixtures of ethanol and water are specified: alcoholometers graduated in percentage of ethanol by volume or by mass and alcohol hydrometers graduated in units of density. Construction, material and scale are described. The dimensions are tabled and the value of the ethanol content by mass or volume and by density and surface tension are given.
- Standard9 pagesEnglish languagee-Library read for
- Standard7 pagesEnglish languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
A system of color coding is specified for one-mark pipettes for identification of nominal capacities, and for graduated pipettes for identification of nominal capacities and unit of subdivision. The color code bands for the different capacities are tabled and the method of marking is specified. Suitable requirements and test methods for the durability of the colours are intended to be considered at a later date.
- Standard4 pagesEnglish languagee-Library read for
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
Frequently Asked Questions
SC 8 is a Technical Committee within the International Organization for Standardization (ISO). It is named "Volume measuring instruments" and is responsible for: Standardization of devices for laboratory purposes including apparatus, instruments and associated supplies which are used to measure volume, with respect to operational and measurement principles, materials of construction, performance, dimensions, marking, testing, as well as the terms and definitions used in connection therewith. This committee has published 33 standards.
SC 8 develops ISO standards in the area of Information technology. The scope of work includes: Standardization of devices for laboratory purposes including apparatus, instruments and associated supplies which are used to measure volume, with respect to operational and measurement principles, materials of construction, performance, dimensions, marking, testing, as well as the terms and definitions used in connection therewith. Currently, there are 33 published standards from this technical committee.
The International Organization for Standardization (ISO) is an independent, non-governmental international organization that develops and publishes international standards. Founded in 1947 and headquartered in Geneva, Switzerland, ISO brings together experts from 170+ member countries to share knowledge and develop voluntary, consensus-based standards that support innovation and provide solutions to global challenges.
A Technical Committee (TC) in ISO is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.