WG 10 - TC 77/SC 77B/WG 10
TC 77/SC 77B/WG 10
General Information
IEC 61000-4-6:2023 is available as IEC 61000-4-6:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61000-4-6: 2023 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz.
NOTE 1 Product committees might decide to use the methods described in this document also for frequencies up to 230 MHz (see Annex B) although the methods and test instrumentation are intended to be used in the frequency range up to 80 MHz.
Equipment not having at least one conducting wire or cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded from the scope of this document.
NOTE 2 Test methods are specified in this part of IEC 61000 to assess the effect that conducted disturbing signals, induced by electromagnetic radiation, have on the equipment concerned. The simulation and measurement of these conducted disturbances are not adequately exact for the quantitative determination of effects. The test methods specified are structured for the primary objective of establishing adequate repeatability of results at various facilities for quantitative analysis of effects.
The object of this document is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by RF fields. The test method in this document describes a consistent method to assess the immunity of an equipment or system against a specified phenomenon.
NOTE 3 As described in IEC Guide 107, this document is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria.
This fifth edition cancels and replaces the fourth edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) selection of injection devices revised;
b) need of AE impedance check for clamp injection removed and Annex H deleted;
c) saturation check revised;
d) new Annex H on testing with multiple signals;
e) level-setting only with feedback loop.
- Standard189 pagesEnglish languagesale 15% off
IEC 61000-4-3:2020 is applicable to the immunity requirements of electrical and electronic equipment to radiated electromagnetic energy. It establishes test levels and the required test procedures. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to radiated, radio-frequency electromagnetic fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against RF electromagnetic fields from RF sources not in close proximity to the EUT. The test environment is specified in Clause 6. NOTE 1 As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products. NOTE 2 Immunity testing against RF sources in close proximity to the EUT is defined in IEC 61000-4-39. Particular considerations are devoted to the protection against radio-frequency emissions from digital radiotelephones and other RF emitting devices. NOTE 3 Test methods are defined in this part for evaluating the effect that electromagnetic radiation has on the equipment concerned. The simulation and measurement of electromagnetic radiation is not adequately exact for quantitative determination of effects. The test methods defined in this basic document have the primary objective of establishing an adequate reproducibility of testing configuration and repeatability of test results at various test facilities. This document is an independent test method. It is not possible to use other test methods as substitutes for claiming compliance with this document. This fourth edition cancels and replaces the third edition published in 2006, Amendment 1:2007 and Amendment 2:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- testing using multiple test signals has been described;
- additional information on EUT and cable layout has been added;
- the upper frequency limitation has been removed to take account of new services;
- the characterization of the field as well as the checking of power amplifier linearity of the immunity chain are specified.
- Standard81 pagesEnglish languagesale 15% off
- Standard164 pagesEnglish and French languagesale 15% off
IEC 61000-4-39:2017 specifies immunity requirements for electrical and electronic equipment when it is exposed to radiated electromagnetic energy from RF transmitters used in close proximity. It establishes test levels and the required test procedures. The applicable frequency range is 9 kHz to 6 GHz. It has the status of a basic EMC publication in accordance with IEC Guide 107.
- Standard82 pagesEnglish and French languagesale 15% off
IEC 61000-4-31:2016 relates to the conducted immunity of electrical and electronic equipment to electromagnetic disturbances coming from intended and/or unintended broadband signal sources in the frequency range 150 kHz up to 80 MHz. It has the status of a basic EMC publication in accordance with IEC Guide 107.
- Standard86 pagesEnglish and French languagesale 15% off
IEC 61000-4-6:2013 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz. Equipment not having at least one conducting wire and/or cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded from the scope of this publication. The object of this standard is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by RF fields. The test method documented in IEC 61000-4-6:2013 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. This fourth edition cancels and replaces the third edition published in 2008 and constitutes a technical revision. It includes the following significant technical changes with respect to the previous edition:
- use of the CDNs;
- calibration of the clamps;
- reorganization of Clause 7 on test setup and injection methods;
- Annex A which is now dedicated to EM and decoupling clamps;
- Annex G which now addresses the measurement uncertainty of the voltage test level;
- and informative Annexes H, I and J which are new. The contents of the corrigendum of June 2015 have been included in this copy.
- Standard168 pagesEnglish and French languagesale 15% off
- Standard12 pagesEnglish and French languagesale 15% off
IEC 61000-4-6:2008 is available as IEC 61000-4-6:2008 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61000-4-6:2008 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 9 kHz up to 80 MHz. Equipment not having at least one conducting cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded. The object of IEC 61000-4-6:2008 is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by radio-frequency fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. IEC 61000-4-6:2008 has the status of a basic EMC publication in accordance with IEC Guide 107. This third edition of IEC 61000-4-6:2008 cancels and replaces the second edition published in 2003, Amendment 1 (2004) and Amendment 2 (2006). This edition cons titutes a technical revision.
- Standard115 pagesEnglish and French languagesale 15% off
- Standard36 pagesEnglish and French languagesale 15% off
Is applicable to the immunity requirements of electrical and electronic equipment to radiated electromagnetic energy. It establishes test levels and the required test procedures. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to radiated, radio-frequency electromagnetic fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. This part deals with immunity tests related to the protection against RF electromagnetic fields from any source. Particular considerations are devoted to the protection against radio-frequency emissions from digital radiotelephones and other RF emitting devices. It has the status of a basic EMC publication.
- Standard111 pagesEnglish and French languagesale 15% off