WG 1 - TC 34/SC 34C/WG 1
TC 34/SC 34C/WG 1
General Information
IEC 62442-3:2022 is available as IEC 62442-3:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62442-3:2022 defines measurement and calculation methods for specifying the efficiency and the standby power of controlgear for tungsten-halogen lamps and LED light sources. This third edition cancels and replaces the second edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- this edition has been harmonized with IEC 62442-1 and IEC 62442-2;
- the reference to and use of the measurement methods for non-active power consumption in accordance with IEC 63103 have been added.
- Standard25 pagesEnglish and French languagesale 15% off
IEC 62442-2:2022 is available as IEC 62442-2:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62442-2:2022 defines a measurement method of the power losses of electromagnetic controlgear, the total input power and the standby power of electronic controlgear for discharge lamps (excluding low-pressure mercury fluorescent lamps). A calculation method of the efficiency of controlgear for discharge lamp(s) is also defined. It is assumed that the controlgear are designed for use on DC supplies up to 1 000 V and/or AC supplies up to 1 000 V at 50 Hz or 60 Hz. This third edition cancels and replaces the second edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- the title of Part 2 has been modified;
- this edition has been harmonized with IEC 62442-1 and IEC 62442-3;
- the reference to and use of the measurement methods for non-active power consumption in accordance with IEC 63103 have been added.
- Standard26 pagesEnglish and French languagesale 15% off
IEC 62442-1:2022 is available as IEC 62442-1:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62442-1:2022 defines a measurement and calculation method of the total input power for controlgear-lamp circuits when operating with their associated fluorescent lamp(s). The calculation method for the efficiency of the lamp controlgear is also defined. This document applies to electrical controlgear-lamp circuits consisting only of the controlgear and the lamp(s). It is intended for use on DC supplies up to 1 000 V and/or AC supplies up to 1 000 V at 50 Hz or 60 Hz. This third edition cancels and replaces the second edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- this edition has been harmonized with IEC 62442-2 and IEC 62442-3;
- the reference to and use of the measurement methods for non-active power consumption in accordance with IEC 63103 have been added.
- Standard41 pagesEnglish and French languagesale 15% off
IEC 62384:2020 is available as IEC 62384:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62384:2020 specifies performance requirements for electronic controlgear for use on DC or AC supplies up to 1 000 V (alternating current at 50 Hz or 60 Hz) and with an output frequency which can deviate from the supply frequency, associated with LED modules according to IEC 62031. Controlgear for LED modules specified in this document are designed to provide constant voltage or current. Deviations from the pure voltage and current types do not exclude the gear from this document. This second edition cancels and replaces the first edition published in 2006 and Amendment 1:2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- scope extension (direct current from 250 V to 1 000 V);
- new specifications for measuring the power factor for controlgear with settable/non-constant output (for instance, to allow for constant light output);
- deletion of audio frequency requirements;
- selection of current test circuit by module capacitance (instead of selecting by having or not having logic circuitry) plus test circuit setup changes.
- Standard28 pagesEnglish and French languagesale 15% off
IEC 62442-2:2018 is also available as IEC 62442-2:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62442-2:2018 defines a measurement method of the power losses of electromagnetic controlgear, the total input power and the standby power of electronic controlgear for high intensity discharged lamps (excluding fluorescent lamps). A calculation method of the efficiency of controlgear for high intensity discharged lamp(s) is also defined. It is assumed that the controlgear are designed for use on DC supplies up to 1 000 V and/or AC supplies up to 1 000 V at 50 Hz or 60 Hz. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision and has been harmonized with IEC 62442-1 and IEC 62442-3.
- Standard26 pagesEnglish and French languagesale 15% off
IEC 62442-3:2018 is also available as IEC 62442-3:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62442-3:2018 defines a measurement method for the power losses of electromagnetic transformers as well as the power losses and the standby power of electronic convertors for tungsten-halogen lamps and for LED light source(s). It is applicable for controlgear that are designed for use on DC supplies up to 1 000 V and/or AC supplies up to 1 000 V at 50 Hz or 60 Hz. A calculation method of the efficiency of the mentioned controlgear for tungstenhalogen lamps and LED light source(s) is also defined. This second edition cancels and replaces the first edition published in 2014. This edition constitutes a technical revision and has been harmonized with IEC 62442-1 and IEC 624422.
- Standard30 pagesEnglish and French languagesale 15% off
IEC 62442-1:2018 is available as IEC 62442-1:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62442-1:2018 defines a measurement and calculation method of the total input power for controlgear-lamp circuits when operating with their associated fluorescent lamp(s). The calculation method for the efficiency of the lamp controlgear is also defined. This document applies to electrical controlgear-lamp circuits consisting only of the controlgear and the lamp(s). It is intended for use on DC supplies up to 1 000 V and/or AC supplies up to 1 000 V at 50 Hz or 60 Hz. This second edition cancels and replaces the first edition published in 2011. This edition constitutes a technical revision and has been harmonized with IEC 62442-2 and IEC 624423.
- Standard41 pagesEnglish and French languagesale 15% off
- Standard24 pagesEnglish and French languagesale 15% off
IEC 61347-1:2015 is available as IEC 61347-1:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61347-1:2015 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. This third edition cancels and replaces the second edition published in 2007, Amendment 1:2010 and Amendment 2:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) additional marking requirements;
b) additional requirements for creepage distances and clearances:
- for working voltages with operating frequencies up to 30 kHz;
- for working voltages with higher operating frequencies than 30 kHz;
- for impulse and resonance voltages ignition;
- for basic, supplementary and reinforced insulation;
- for insulation between circuits;
- for coated or potted controlgear;
c) modification of definition of ELV and FELV;
d) modification of schematic drawing, showing the different controlgear classification and insulation requirements;
e) scope extension;
f) new Annex A: test to establish whether a conductive part is a live part which may cause an electric shock;
g) new Annex M: creepage distances and clearances for controlgear where a higher degree of availability (impulse withstand category III) may be requested;
h) new Annex Q: example for Up calculation;
i) new Annex P: creepage distances and clearances and distance through isolation (DTI) for lamp controlgear which are protected against pollution by the use of coating or potting;
j) new Annex R: concept of creepage distances and clearances.
This publication is to be read in conjunction with theIEC 61347-2 series
- Standard248 pagesEnglish and French languagesale 15% off
Defines the grades of grain-oriented electrical steel sheet in nominal thicknesses of 0,23 mm, 0.27 mm, 0.30 mm and 0.35 mm. Gives general requirements, magnetic properties, geometric characteristics and tolerances, and technological characteristics, as well as inspection procedures. Applies to Goss textured grain-oriented electrical steel sheet supplied in the final annealed condition in sheets or coils, and intended for the construction of magnetic circuits.
- Standard16 pagesEnglish and French languagesale 15% off
This first edition of IEC 61347-2-11, published in conjunction with IEC 61347-1, represents an editorial review of IEC 60920. The formatting into separately published parts provides for ease of future amendments and revisions. Additional requirements will be added as and when a need for them is recognized. This part of IEC 61347 specifies general and safety requirements for miscellaneous electronic circuits used with luminaires for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz and/or d.c. supplies up to 250 V. This part does not apply to circuits or devices for which specific IEC standards are published. This first edition of IEC 61347-2-11, together with IEC 61347-1, cancels and replaces the first edition of IEC 60920, published in 1990, and constitutes a minor revision. This standard shall be used in conjunction with IEC 61347-1. The contents of the corrigendum of December 2001 have been included in this copy.
- Standard15 pagesEnglish and French languagesale 15% off
- Standard4 pagesEnglish and French languagesale 15% off
- Standard5 pagesEnglish and French languagesale 15% off
IEC 61347-2-13:2014 specifies particular safety requirements for electronic controlgear for use on d.c. or a.c. supplies up to 1 000 V (a.c. at 50 Hz or 60 Hz) and at an output frequency which can deviate from the supply frequency, associated with LED modules. Controlgear for LED modules specified in this standard are designed to provide constant voltage or current at SELV or higher voltages. Deviations from the pure voltage and current types do not exclude the gear from this standard. This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition.
a) Replacement of the SELV-equivalent requirements by SELV requirements and reference to the SELV requirements of Annex L in IEC 61347-1:2007/AMD2:2012.
b) Reference to IEC 61347-1 for the protection against accidental contact with live parts, moisture resistance and insulation and electric strength.
c) New Annex J for emergency lighting requirements.
This publication shall be read in conjunction with IEC 61347-1:2012.
- Standard50 pagesEnglish and French languagesale 15% off
IEC 61347-2-3:2011 specifies particular safety requirements for electronic control gear for use on a.c. and d.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation. This second edition cancels and replaces the first edition published in 2000, its Amendment 1 (2004) and its Amendment 2 (2006), IEC 61347-2-4 published in 2000, IEC 61347-2-5 published in 2000 and IEC 61347-2-6 published in 2000. This second edition constitutes a technical revision. The significant revisions with respect to the first edition are:
- rectifying test conditions when dimming;
- construction requirements;
- measurement circuits and limits for HF leakage currents;
- modification of the structure to become a standard exclusively for a.c. and d.c. central supplied electronic control gear for general lighting and Annex J cover centrally- supplied emergency control gear.
This publication is to be read in conjunction with IEC 61347-1:2007. The contents of the corrigendum of September 2011 have been included in this copy.
- Standard88 pagesEnglish and French languagesale 15% off
Specifies essential requirements for the performance of transcutaneous oxygen and carbon dioxide partial pressure monitoring equipment.[
]Applies to transcutaneous monitors intended for use with adults, children and neonates, and includes the use of these devices in foetal monitoring during birth.[
]Does not apply to haemoglobin saturation oximeters or to devices applied to surfaces of the body other than the skin such as conjunctiva or mucosa.
- Standard8 pagesEnglish and French languagesale 15% off
- Standard61 pagesEnglish and French languagesale 15% off
- Standard12 pagesEnglish and French languagesale 15% off
IEC 62811:2015 specifies performance requirements for electronic controlgear for use on a.c. and/or d.c. supplies up to 1 000 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with discharge lamps, as specified in IEC 61167, which have information for low frequency square wave operation, where the frequency range of the low frequency is from 70 Hz to 400 Hz.
- Standard67 pagesEnglish and French languagesale 15% off
IEC 62442-3:2014 defines a measurement method for the power losses of magnetic transformers and the power losses with the standby power of electronic convertor for halogen lamps and LED modules. Also a calculation method of the efficiency for the mentioned controlgear for halogen lamps and LED modules is defined.
- Standard29 pagesEnglish and French languagesale 15% off
This part of IEC 61347 specifies particular safety requirements for starting devices (starters other than glow starters and ignitors) for fluorescent and other discharge lamps for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz which produce starting pulses not greater than 100 kV and which are used in combination with lamps and ballasts covered in IEC 60081, IEC 60188, IEC 60192, IEC 60662, IEC 60901, IEC 61167, IEC 61195, IEC 61199, IEC 61347-2-8 and IEC 61347-2-9. It does not apply to glow starters or starting devices which are incorporated in discharge lamps or which are manually operated. Preheat transformers for fluorescent lamps are covered by IEC 61347-2-8. This first edition of IEC 61347-2-1, together with IEC 61347-1, cancels and replaces the second edition of IEC 60926, published in 1995, and constitutes a minor revision. This standard shall be used in conjunction with IEC 61347-1. It was established on the basis of the first edition (2000) of that standard.
- Standard39 pagesEnglish and French languagesale 15% off
Applies to string insulator units of the can and pin type and also of the long rod type as well as to the fittings used with such insulators. Defines dimensions of a series of clevis and tongue couplings to permit the assembly of insulators or fittings supplied by different manufacturers.[
]Note: -For co-ordination between standardized dimensions and strength classes of cap and pin type insulators and long rod type insulators see IEC 60305 and 60433.
- Standard13 pagesEnglish and French languagesale 15% off
- Standard5 pagesEnglish and French languagesale 15% off
- Standard64 pagesEnglish and French languagesale 15% off
IEC 61347-2-9:2012 series specifies particular safety requirements for electromagnetic controlgear for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. The standard covers inductive-type electromagnetic controlgear for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with discharge lamps, having rated wattages, dimensions and characteristics as specified in IEC 60188, IEC 60192 and IEC 60662. This second edition cancels and replaces the first edition published in 2000, Amendment 1:2003 and Amendment 2:2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the addition of a new Clause 14;
b) the word "ballast" is changed to "electromagnetic controlgear".
This publication is to be read in conjunction with IEC 61347-1:2007.
- Standard61 pagesEnglish and French languagesale 15% off
IEC 61347-2-7:2011 specifies particular safety requirements for battery supplied electronic controlgear for maintained and non-maintained emergency lighting purposes. It includes specific requirements for electronic controlgear and control units for self-contained luminaires for emergency lighting as specified by IEC 60598-2-22. This third edition cancels and replaces the second edition published in 2006. It constitutes a technical revision. Significant changes introduced into this third edition include:
- modification of IEC 61347-2-7 to become a standard exclusively for d.c. battery supplied electronic controlgear for emergency lighting (self-contained) IEC 61347-2-3 Annex J is intended to cover centrally supplied emergency controlgear;
- update of Clause 22 - Recharging devices;
- modification of Clause 20 battery voltage characterisation to support EBLF measurement. This to simplify and increase reproducibility of testing;
- rationalisation of requirements between IEC 61347-2-7 and IEC 60598-2-22 requirements of IEC 60598-2-22 being transferred to IEC 61347-2-7.
This publication is to be read in conjunction with IEC 61347-1:2007.
- Standard185 pagesEnglish and French languagesale 15% off
- Standard70 pagesEnglish and French languagesale 15% off
IEC 61347-2-2:2011 specifies particular safety requirements for electronic step-down convertors for use on d.c. supplies of up to 250 V or a.c. supplies of up to 1 000 V, at 50 Hz or 60 Hz and with rated output voltage 50 V r.m.s. at a frequency deviating from the supply frequency, or 120 V ripple free d.c. between conductors and between any conductor and earth, associated with tungsten-halogen lamps as specified in IEC 60357 and other filament lamps. This second edition of IEC 61347-2-2 replaces the first edition (2000), Amendment 1 (2005) and Amendment 2 (2006). The major modification for this second edition is the changeover from SELV equivalent to SELV.
This publication is to be read in conjunction with IEC 61347-1:2007.
- Standard28 pagesEnglish and French languagesale 15% off
IEC 62442-1:2011 defines a measurement and calculation method of the total input power for controlgear - lamp circuits when operating with their associated fluorescent lamp(s). The calculation method for the efficiency of the lamp controlgear is also defined. This International Standard applies to electrical controlgear lamp circuits consisting only of the controlgear and the lamp(s). It is intended for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz.
- Standard38 pagesEnglish and French languagesale 15% off
IEC 60929:2011 specifies performance requirements for electronic control gear for use on a.c. at 50 Hz or 60 Hz and/or d.c. supplies, both up to 1 000 V, with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation. This fourth edition cancels and replaces the third edition published in 2006, IEC 60925 published in 1989, its Amendment 1 (1996) and its Amendment 2 (2001). This fourth edition constitutes a technical revision. The essential change with respect to the third edition is the extension to DC supplied control gear and the deletion of the requirements for digital signal control of electronic control gear. The contents of the corrigendum of September 2011 have been included in this copy.
- Standard82 pagesEnglish and French languagesale 15% off
- Standard8 pagesEnglish and French languagesale 15% off
- Standard13 pagesEnglish and French languagesale 15% off
- Standard5 pagesEnglish and French languagesale 15% off
This part of IEC 61347 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. This standard also covers lamp controlgear for lamps which are not yet standardized. Tests dealt with in this standard are type tests. Requirements for testing individual lamp controlgear during production are not included. This part 1 is to be used in conjunction with the appropriate part 2, which contains clauses to supplement or modify the corresponding clauses in part 1, to provide the relevant requirements for each type of product. This first edition of IEC 61347-1, together with parts 1 to 9 of IEC 61347-2, cancels and replaces IEC 60920, IEC 60922, IEC 60924, IEC 60926, IEC 60928 and IEC 61046, and constitute a minor revision. The relationship between the parts that make up IEC 61347-2 and the IEC standards they replace is detailed as follows: IEC 61347-2-1 replaces IEC 60926 IEC 61347-2-2 replaces IEC 61046 IEC 61347-2-3 replaces IEC 60928 IEC 61347-2-4 replaces IEC 60924, Section 3 IEC 61347-2-5 replaces IEC 60924, Section 4 IEC 61347-2-6 replaces IEC 60924, Section 5 IEC 61347-2-7 replaces IEC 60924, Section 6 IEC 61347-2-8 replaces IEC 60920 IEC 61347-2-9 replaces IEC 60922
- Standard43 pagesEnglish and French languagesale 15% off
This International Standard specifies performance requirements for starting devices (starters and ignitors) for tubular fluorescent and other discharge lamps for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, which produce starting pulses not greater than 5 kV. This standard is used in conjunction with IEC 61347-1 and IEC 61347-2-1.
- Standard61 pagesEnglish and French languagesale 15% off
- Standard3 pagesEnglish and French languagesale 15% off
- Standard3 pagesEnglish and French languagesale 15% off
This International Standard states the requirements for both self-healing and non-self-healing continuously rated a.c. capacitors of up to and including 2,5 kVAr, and not less than 0,1 µF, having a rated voltage not exceeding 1 000 V, which are intended for use in discharge lamp circuits operating at 50 Hz or 60 Hz and at altitudes up to 3 000 m.
- Standard71 pagesEnglish and French languagesale 15% off
This part of IEC 61347 specifies safety requirements for ballasts, excluding resistance types, for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with fluorescent lamps with or without pre-heated cathodes operated with or without a starter or starting device and having rated wattages, dimensions and characteristics as specified in IEC 60081 and 60901. This first edition of IEC 61347-2-8, together with IEC 61347-1, cancels and replaces the first edition of IEC 60920, published in 1990, and constitutes a minor revision. This standard shall be used in conjunction with IEC 61347-1. It was established on the basis of the first edition (2000) of that standard.
- Standard39 pagesEnglish and French languagesale 15% off
The contents of the corrigendum of August 2012 have been included in this copy.
- Standard9 pagesEnglish and French languagesale 15% off
- Standard7 pagesEnglish and French languagesale 15% off
This International Standard specifies performance requirements for ballasts for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. Clauses 12 through 15 each detail specific requirements for a particular type of ballast. This standard covers inductive type ballasts for use on a.c. supplies up to 1 000 V at 50 Hz to 60 Hz associated with discharge lamps, having rated wattage, dimensions and characteristics as specified in the relevant IEC lamp standards.
- Standard53 pagesEnglish and French languagesale 15% off
This standard specifies performance requirements for ballasts excluding resistance types for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with tubular fluorescent lamps with pre-heated cathodes operated with or without a starter or starting device and having rated wattages, dimensions and characteristics as specified in IEC 60081 and 60901. It applies to complete ballasts and their component parts such as resistors, transformers and capacitors.
- Standard63 pagesEnglish and French languagesale 15% off
This International Standard specifies performance requirements for electronic step-down convertors for use on d.c. supplies up to 250 V and a.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with tungsten halogen lamps as specified in IEC 60357 and other filament lamps.
- Standard33 pagesEnglish and French languagesale 15% off