Abstract

Applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety and to the testing of thermal protectors for ballasts for tubular fluorescent lamps supplied up to 600 V (50 Hz or 60 Hz).

Status
Published
Publication Date
29-Feb-1996
Technical Committee
EPR - Electrical accessories
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Mar-1996
Due Date
01-Mar-1996
Completion Date
01-Mar-1996

Buy Documents

Standard

SIST EN 60730-2-3:1996

English language (18 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN 60730-2-3:1996 is a Slovenian national standard published by the Slovenski inštitut za standardizacijo. It gives particular requirements for thermal protectors for ballasts for tubular fluorescent lamps, including inherent safety, operating values, operating times, operating sequences, and testing for equipment supplied up to 600 V at 50 Hz or 60 Hz. It is the document to use when you need a safety-focused specification for this component in fluorescent lighting equipment.

What does SIST EN 60730-2-3:1996 specify?

SIST EN 60730-2-3:1996 specifies the particular requirements for thermal protectors used with ballasts for tubular fluorescent lamps. The scope ties those requirements to safety-related behavior, so the document matters when the protector is part of the equipment's safety function, not just its normal operation.

The standard applies to equipment supplied up to 600 V and at 50 Hz or 60 Hz. That supply limit matters in practice because it sets the electrical conditions under which the protector is assessed and tested.

The document is presented as Part 2-3 of the EN 60730 series and is identified as a modified version of IEC 730-2-3:1990. In other words, it is a particular-requirements standard for one component family within automatic electrical controls for household and similar use.

What are the key requirements of SIST EN 60730-2-3:1996?

The technical focus is on how a thermal protector behaves when safety depends on it. The scope points to four main areas: inherent safety, operating values, operating times, and operating sequences, plus testing.

  • Inherent safety - The protector must be suitable as a safety-related component in the ballast assembly. In practice, designers and buyers need to treat it as part of the protective function, not only as a convenience feature.

  • Operating values - The document covers the values at which the protector operates. This matters because those values define when protection begins, so they are central to product selection and verification.

  • Operating times - The protector's response time is part of the scope. For a thermal protector, timing can determine whether overheating is controlled before damage or hazard develops.

  • Operating sequences - The standard addresses the sequence in which safety-relevant actions occur. This matters when the protector must change state in a predictable order during normal use or fault conditions.

  • Testing - The standard includes testing for these thermal protectors. Test evidence is what manufacturers, labs, and purchasers use to check whether a protector behaves as specified under the intended electrical conditions.

  • Application limit - The document is for ballasts for tubular fluorescent lamps supplied up to 600 V at 50 Hz or 60 Hz. If the product is outside that service envelope, this standard is not the right basis for specification or test planning.

Who uses SIST EN 60730-2-3:1996?

SIST EN 60730-2-3:1996 is used by people who design, test, specify, approve, or buy thermal protectors and ballasts for tubular fluorescent lamps. It is also relevant to quality and compliance teams that need a common basis for checking safety-related operating behavior.

Typical users include ballast manufacturers, thermal protector suppliers, laboratory staff, and technical buyers in the lighting industry. They use the standard to align product design with the safety behavior expected for this component type.

What does the SIST EN 60730-2-3:1996 document contain?

SIST EN 60730-2-3:1996 contains the front matter identifying it as the Slovenian edition, first edition, March 1996, and as a modified version of IEC 730-2-3:1990. Its technical content centers on the scope for thermal protectors for ballasts for tubular fluorescent lamps, including the safety-related operating characteristics and testing covered by the standard.

The document is a narrow, component-focused part of the EN 60730 family. It is intended for technical work on specification, testing, and product acceptance for this lighting application.

Relations

Effective Date
01-Sep-2010
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
03-Feb-2026
Effective Date
21-Sep-2010
Effective Date
21-Sep-2010
Effective Date
21-Sep-2010

Buy Documents

Standard

SIST EN 60730-2-3:1996

English language (18 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)

Italian electrical product certification.

ACCREDIA Italy Verified

SLG Prüf- und Zertifizierungs GmbH

German testing and certification body.

DAKKS Germany Verified

UL Solutions

Global safety science company with testing, inspection and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

SIST EN 60730-2-3:1996 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Automatic electrical controls for household and similar use -- Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps". This standard covers: Applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety and to the testing of thermal protectors for ballasts for tubular fluorescent lamps supplied up to 600 V (50 Hz or 60 Hz).

Applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety and to the testing of thermal protectors for ballasts for tubular fluorescent lamps supplied up to 600 V (50 Hz or 60 Hz).

SIST EN 60730-2-3:1996 is classified under the following ICS (International Classification for Standards) categories: 29.140.30 - Fluorescent lamps. Discharge lamps; 97.120 - Automatic controls for household use. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 60730-2-3:1996 has the following relationships with other standards: It is inter standard links to SIST EN 60730-2-3:2008, SIST EN 61558-1:2006, SIST EN 61046:2000, SIST EN 60928:1995, SIST EN 60922:1999, SIST EN 61347-1:2002, SIST EN 60730-2-3:1996/A2:2002, SIST EN 60730-2-3:1996/A11:2005, SIST EN 60730-2-3:1996/A1:1998. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 60730-2-3:1996 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 73/23/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN 60730-2-3:1996 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI SIST EN 60730-2-3:1996
prva izdaja
STANDARD
marec 1996
Automatic electrical controls for household and similar use - Part 2: Particular
requirements for thermal protectors for ballasts for tubular fluorescent lamps (IEC
730-2-3:1990, modified)
ICS 29.1
...