KNG - Automatic controls for household use
Standardization of rules related to inherent safety, to the operating characteristics, where such are associated with applicational safety, and to testing of automatic electrical control devices used in appliances and other apparatus, electrical and non- electrical, for househould and similar general puroses such as that for central heating, air conditioning, etc.
Krmilne naprave za gospodinjstvo - preoblikovan v SS EIT.NZG
Standardizacija varnosti, obratovalnih karakteristik, kjer so le-te povezane z uporabno varnostjo, in preskušanje avtomatskih krmilnih naprav, uporabljenih v gospodinjskih aparatih in napravah za splošno uporabo, kot centralno ogrevanje, klimatizacija itd.
General Information
D126/C042: IEC 60730 series permanently excluded from parallel procedures * TC 72 request: 2MV on IEC without CM
- Amendment12 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60730 applies to controls for automatically controlling the starting windings of single phase motors associated with equipment for household and similar use. This standard applies to motor-starting relays using NTC or PTC thermistors, additional requirements for which are contained in Annex J.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60730 applies to automatic electrical humidity sensing controls for use in, on or in association with equipment for household and similar use, including controls for heating, air-conditioning and similar applications. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60730 applies to the partial evaluation of thermal motor protectors as defined in IEC 60730-1 for sealed (hermetic and semi-hermetic type) motor-compressors. A thermal motor protector is an integrated control which is dependent on its correct mounting and fixing in or on a motor and which can only be fully tested in combination with the relevant motor. Requirements concerning the testing of the combination of motor and thermal motor protectors are given in IEC 60335-2-34. This standard applies to thermal motor protectors for motor compressors using NTC or PTC thermistors, additional requirements for which are contained in Annex J. This standard applies to the inherent safety, to the operating values, operating times, and operating sequences, where such are associated with equipment safety, and to the testing of thermal motor protectors used in or on sealed (hermetic and semi-hermetic type) motor-compressors. This standard applies to thermal motor protectors for motor-compressors within the scope of IEC 60335-2-34. Thermal motor protectors for motor compressors not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. This standard does not apply to thermal motor protectors designed exclusively for industrial applications.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60730 applies to the evaluation of thermal protectors for ballasts for tubular fluorescent lamps. This standard applies to thermal protectors using NTC or PTC thermistors, additional requirements for which are contained in Annex J. Requirements concerning the testing of the combination of ballasts and thermal protectors are given in IEC 61347-1. This standard applies to the inherent safety, to the operating values, operating times, and operating sequences where such are associated with equipment safety, and to the testing of thermal protectors used to protect ballasts for tubular lamps from overheating. This standard applies to thermal protectors for ballasts within the scope of IEC 61347-2-8. Thermal protectors covered by this standard may be suitable for ballasts for other discharge lamps such as ballasts under the scope of IEC 61347-2-9.
This International Standard applies to flexible cables with insulation based on ethylene propylene rubber (EPR), polyvinyl chloride (PVC) or silicone rubber (SiR) for portable earthing and short-circuiting equipment. For this type of cable no rated voltage is given as such cables are exclusively intended for earthing and short-circuiting equipment. The particular types of cable and their code designations are specified in Clause 6 of this standard. The test methods specified in this standard are given in IEC 60227-2, IEC 60245-2, IEC 60811 and IEC 62230.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
Same dow as in A12, A14 and A15 * To be ratified as EN 60730-1:2000/A16
- Amendment12 pagesEnglish languagesale 10% offe-Library read for1 day
This standard applies to the partial evaluation of thermal motor protectors as defined in Publication 730-1 for household and similar use including heating, air conditioning and similar applications. This standard applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety and to the testing of thermal motor protectors used in or on household or similar equipment. This standard does not apply to other means of motor protection. This standard does not apply to a manual device for opening the circuit. This standard does not apply to thermal motor protectors for hermetic or semi-hermetic motor compressors. This standard applies to thermal motor protectors for use with electric motors with a rated voltage equal to or less than 660 V and a rated output of 11 kW or less.
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-2-3:2007
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
This standard applies to the partial evaluation of thermal motor protectors as defined in Publication 730-1 for household and similar use including heating, air conditioning and similar applications. This standard applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety and to the testing of thermal motor protectors used in or on household or similar equipment. This standard does not apply to other means of motor protection. This standard does not apply to a manual device for opening the circuit. This standard does not apply to thermal motor protectors for hermetic or semi-hermetic motor compressors. This standard applies to thermal motor protectors for use with electric motors with a rated voltage equal to or less than 660 V and a rated output of 11 kW or less.
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-2-13:2008
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-1:2011
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
2021: CLC legacy converted by DCLab NISOSTS
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Supersedes EN 60730-1:2000/A11:2002
- Amendment45 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-1:2011
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-1:2011
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-1:2000/A12:2003
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-2-4:2007
- Amendment9 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-2-13:2008
- Amendment9 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to electrically operated oil valves for use in, on or in association with equipment for household and similar use that use electricity, in combination with fuel in the liquid state such as distillates, residual fuels, etc. This part 2 also applies to electrically operated oil valves using NTC or PTC thermistors.
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-2-10:2007
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to the partial evaluation of thermal motor protectors and their inherent safety. Applies also to thermal motor protectors within the scope of EN 60335-1.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
Corrigendum to EN issued October 2001
- Standard5 pagesEnglish languagesale 10% offe-Library read for1 day
EN following parallel vote
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
EN following parallel vote
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to automatic electrical controls for household and similar use. Part 1 gives the general requirements. Parts 2 to be used in conjunction with Part 1 will give particular requirements for specific types of controls.
- Standard285 pagesEnglish languagesale 10% offe-Library read for1 day
Supersedes A13:1998 * Superseded by EN 60730-1:2000
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-1:2000
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-1:2000
- Amendment15 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment15 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-1:1995
- Amendment26 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-1:2000
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
In general, this standard applies to automatic electrical controls for houselold and similar use, including electrical controls for heating, air conditioning, and similar applications. This standard applies to controls with a rated voltage not exceeding 660 V and with a rated current not exceeding 63 A. This standard does not take into account the response value of an automatic action of a control. If such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer shall apply.
- Standard165 pagesEnglish languagesale 10% offe-Library read for1 day
Corrigendum to EN/A1 issued May 2000
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-1:2000
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to automatic electrical humidity sensing controls for use in, on or in association with equipment for household and similar use, including controls for heating, air-conditioning and similar applications. The equipment may use electricity, gas, oil, fuel, solar thermal energy, etc. or a combination thereof.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
D106/050: New dow * Corrigendum to EN/A1 issued March 2001
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
Implementation dates aligned with those of A2 * Superseded by EN 60730-1:2000
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to electric actuators for use in, on, or in association with equipment for household and similar use for heating, air-conditioning and ventilation. The equipment may use electricity, gas, oil solid fuel, solar thermal energy, etc., or a combination thereof.
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
Implementation dates aligned with those of A2 * Superseded by EN 60730-1:2000
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
D106/050: New dow * Corrigendum to EN/A1 issued March 2001
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-1:2000
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to controls for automatically controlling the starting windings of single phase motors associated with equipment for household and similar use (including starting relays incorporating electronic devices and starting relays using thermistor elements, thermal elements and magnetic elements). Specifies inherent safety, operating values, operating times, and the testing of full motor starting relays.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
D106/050: New dow * Corrigendum to EN/A1 issued March 2001
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
65 BT decision: Editorially combined with AA, AB, AC and AD * Superseded by EN 60730-1:1995
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60730-1:1995
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
In general this standard applies to automatic electrical controls for use in, on, or in association with equipment for household and similar use, including controls for heating, air-conditioning and similar applications. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc, or a combination thereof. This standard applies to automatic electric controls using NTC or PTC thermistors, additional requirements for which are contained in annex J of this standard. This standard applies to the inherent safety; to the operating values, operating times, and operating sequences where such are associated with equipment safety; and to the testing of automatic electrical control devices used in, or in association with, household or similar equipment. This standard does not apply to automatic electrical controls designed exclusively for industrial applications. This standard is also applicable to individual controls utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs. Automatic electrical controls for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.
- Standard254 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60730-2-7:2008 applies to timers and time switches for household and similar use that may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof, including heating, air conditioning and similar applications. This second edition cancels and replaces the first edition published in 1990 and its Amendment 1 (1994). This second edition constitutes a technical revision. This new edition incorporates requirements for tungsten filament lamp loadings as well as updates the standard to IEC 60730-1:1999, Amendment 2 (2007). This Part 2-7 is to be used in conjunction with IEC 60730-1. It was established on the basis of the third edition of that standard (1999) and its Amendment 1 (2003) and Amendment 2 (2007). Consideration may be given to future editions of, or amendments to, IEC 60730-1.
- Draft27 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment16 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to automatic electrical burner control systems for the automatic control of burners for oil, gas, coal or other combustibles for household and similar use including heating, air conditioning and similar use. To be used in conjunction with EN 60730-1 (second edition).
- Standard54 pagesEnglish languagesale 10% offe-Library read for1 day