SIST EN 1229:1997
(Main)Plastics piping systems - Glass-reinforced thermosetting plastics (GRP) pipes and fittings - Test methods to prove the leaktightness of the wall under short-term internal pressure
- Abstract
This standard specifies two test methods, designated method A and method B, for rapid testing of the leaktightness of glass-reinforced thermosetting plastics (GRP) pipes and fittings under short-term internal pressure. Method A is a hydraulic test applicable to a pipe under uniaxial stress. Method B is a pneumatic test applicable pipes and fittings. For pipes it is intended to be complementary to method A, not an alternative test.
- Status
- Published
- Publication Date
- 31-Jan-1997
- Technical Committee
- PCV - Plastic pipes, fittings and valves
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Feb-1997
- Due Date
- 01-Feb-1997
- Completion Date
- 01-Feb-1997
SIST EN 1229:1997 is the Slovenski inštitut za standardizacijo edition of a test-method standard for glass-reinforced thermosetting plastics (GRP) pipes and fittings. It specifies two rapid methods for proving leaktightness of the wall under short-term internal pressure, so manufacturers and test laboratories can check whether a pipe or fitting holds pressure without leakage.
What does SIST EN 1229:1997 specify?
SIST EN 1229:1997 specifies two test methods, Method A and Method B, for rapid testing of the wall leaktightness of GRP pipes and fittings under short-term internal pressure. The standard is centered on the test methods themselves, with Method A intended for hydraulic testing of a pipe under uniaxial stress and Method B intended for pneumatic testing of pipes and fittings.
For pipes, Method B is presented as complementary to Method A, not as a replacement. In practice, that means a pipe manufacturer or test lab may use both methods for different purposes, rather than treating the pneumatic test as an alternative to the hydraulic one.
What are the key requirements of SIST EN 1229:1997?
SIST EN 1229:1997 organizes its technical content around the two named methods and the pressure condition they share. The main practical point is to demonstrate wall leaktightness under a short-term internal pressure test.
- Method A is hydraulic. It applies to a pipe under uniaxial stress. In practice, this points to a water-based test on pipe specimens where the loading condition is controlled and repeatable.
- Method B is pneumatic. It applies to pipes and fittings. In practice, this gives a gas-pressure route for checking leakage behavior on both product types.
- Method B is complementary for pipes. The standard states that, for pipes, the pneumatic method is not the same role as Method A. In practice, users should not treat it as a straight substitute when defining their test plan.
- The target is wall leaktightness. The test is aimed at the pipe or fitting wall under pressure, not at general appearance or dimensional checks. In practice, the result is about whether the wall remains leak-tight during the test.
- The pressure condition is short-term internal pressure. The standard focuses on rapid testing rather than long-duration pressure exposure. In practice, that makes it useful for routine production checks and incoming inspection.
- The scope covers GRP pipes and fittings. In practice, the document is relevant where products are made from glass-reinforced thermosetting plastics and need pressure-leakage verification.
What terms does SIST EN 1229:1997 define?
Glass-reinforced thermosetting plastics (GRP) are plastic products reinforced with glass and based on a thermosetting matrix; in this standard, the term identifies the pipe and fitting material family being tested.
Method A is the hydraulic test method named by the standard for pipes under uniaxial stress; it gives a water-based route for pressure-leakage verification.
Method B is the pneumatic test method named by the standard for pipes and fittings; it uses gas pressure to check leaktightness.
Uniaxial stress means loading in one principal direction; here it describes the stress condition used for the pipe during Method A.
Leaktightness means the wall can retain pressure without leaking through the material or wall structure; this is the performance the test is meant to prove.
Short-term internal pressure means pressure applied for a brief test period; it separates this method from long-term pressure endurance testing.
Who uses SIST EN 1229:1997?
SIST EN 1229:1997 is used by manufacturers of GRP pipes and fittings, laboratory staff running pressure tests, and quality control teams checking product consistency. It is also useful to purchasers, inspectors, and specifiers who need a common test method when comparing products or verifying conformance in plastics piping systems.
What changed in SIST EN 1229:1997 from the previous edition?
SIST EN 1229:1997 is identified as identical to EN 1229:1996.
What does the SIST EN 1229:1997 document contain?
The document contains the technical basis for two rapid leaktightness test methods and distinguishes clearly between hydraulic and pneumatic testing. Its content is centered on the test approach for GRP pipes and fittings under short-term internal pressure, with Method A tied to pipes under uniaxial stress and Method B tied to pipes and fittings.
It also gives the language needed to use the methods consistently in practice, so test labs and production teams can apply the same terms when planning or reporting pressure tests. The front matter shows the standard’s multilingual presentation and its classification within reinforced plastics and plastics pipes/fittings.
Relations
- Effective Date
- 28-Jan-2026
Get Certified
Connect with accredited certification bodies for this standard
DIN CERTCO
DIN Group product certification.
Institut za varilstvo d.o.o. (Welding Institute)
Slovenia's leading welding institute since 1952. ISO 3834, EN 1090, pressure equipment certification, NDT personnel, welder qualification. Only IIW Au

Smithers Quality Assessments
US management systems and product certification.
Sponsored listings
Frequently Asked Questions
SIST EN 1229:1997 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Plastics piping systems - Glass-reinforced thermosetting plastics (GRP) pipes and fittings - Test methods to prove the leaktightness of the wall under short-term internal pressure". This standard covers: This standard specifies two test methods, designated method A and method B, for rapid testing of the leaktightness of glass-reinforced thermosetting plastics (GRP) pipes and fittings under short-term internal pressure. Method A is a hydraulic test applicable to a pipe under uniaxial stress. Method B is a pneumatic test applicable pipes and fittings. For pipes it is intended to be complementary to method A, not an alternative test.
This standard specifies two test methods, designated method A and method B, for rapid testing of the leaktightness of glass-reinforced thermosetting plastics (GRP) pipes and fittings under short-term internal pressure. Method A is a hydraulic test applicable to a pipe under uniaxial stress. Method B is a pneumatic test applicable pipes and fittings. For pipes it is intended to be complementary to method A, not an alternative test.
SIST EN 1229:1997 is classified under the following ICS (International Classification for Standards) categories: 23.040.20 - Plastics pipes; 23.040.45 - Plastics fittings; 83.120 - Reinforced plastics. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 1229:1997 has the following relationships with other standards: It is inter standard links to SIST EN ISO 3231:1998. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 1229:1997 is associated with the following European legislation: EU Directives/Regulations: 305/2011, 89/106/EEC. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 1229:1997 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kunststoff-Rohrleitungssysteme - Rohre und Formstücke aus glasfaserverstärkten duroplastischen Kunststoffen (GFK) - Prüfverfahren zur Feststellung der Dichtigkeit der Wand unter Kurzzeit-InnendruckSystemes de canalisations en plastique - Tubes et raccords en plastique thermodurcissable renforcé de verre (PRV) - Méthode d'essai pour établir l'étanchéité de la paroi sous une pression interne a court termePlastics piping systems - Glass-reinforced th
...