ISO 14122-4:2016
(Main)Safety of machinery — Permanent means of access to machinery — Part 4: Fixed ladders
Safety of machinery — Permanent means of access to machinery — Part 4: Fixed ladders
ISO 14122-4:2016 gives requirements for fixed ladders which are a part of a stationary machine, and to the non-powered adjustable parts (e.g. foldable, slidable) and movable parts of fixed ladder systems. NOTE 1 "Fixed" means of access are those mounted in such a manner (for example, by screws, nuts, welding) that they can only be removed by the use of tools. ISO 14122-4:2016 specifies minimum requirements that also apply when the same means of access is required as the part of the building or civil construction (e.g. fixed ladders) where the machine is installed, on condition that the main function of that part of the construction is to provide a means of access to the machine. NOTE 2 Where no local regulation or standards exists, this part of ISO 14122 may be used also for means of access which are outside the scope of the standard. It is intended that this part of ISO 14122 be used with ISO 14122‑1 to give the requirements for fixed ladder systems. The ISO 14122 series as a whole is applicable to both stationary and mobile machinery where fixed means of access are necessary. It is not applicable to powered means of access such as lifts, escalators, or other devices specially designed to lift persons between two levels. ISO 14122-4:2016 is not applicable to machinery manufactured before the date of its publication.
Sécurité des machines — Moyens d'accès permanents aux machines — Partie 4: Échelles fixes
ISO 14122-4:2016 donne les exigences pour les échelles fixes qui font partie intégrante d'une machine fixe et aux parties réglables non-motorisées (par exemple pliables, coulissantes) ainsi qu'aux parties mobiles de ces systèmes d'échelles fixes. NOTE 1 Les moyens d'accès «fixes» sont ceux montés de telle manière (par exemple par boulonnage, par soudage) qu'ils ne puissent être démontés qu'à l'aide d'outils. ISO 14122-4:2016 spécifie les exigences minimales s'appliquant également aux moyens d'accès fixes aux parties du bâtiment ou de la construction civile (par exemple échelles fixes) où la machine est installée, à condition que la fonction principale de cette partie de la construction soit de donner accès à la machine. NOTE 2 Lorsqu'aucune norme nationale ou réglementation n'existe, la présente partie de l'ISO 14122 peut être utilisée pour les moyens d'accès en dehors de son domaine d'application. Il est prévu que la présente partie de l'ISO 14122 soit utilisée conjointement avec l'ISO 14122‑1 pour donner les exigences relatives aux systèmes d'échelles fixes. L'ensemble de la série ISO 14122 est applicable aux machines fixes et mobiles pour lesquelles des moyens d'accès fixes sont nécessaires. Cette série n'est pas applicable aux moyens d'accès motorisés tels que les ascenseurs, les escalators, ou d'autres dispositifs conçus spécialement pour soulever des personnes entre deux niveaux. ISO 14122-4:2016 n'est pas applicable aux machines fabriquées avant sa date de publication.
General Information
- Status
- Published
- Publication Date
- 26-May-2016
- Technical Committee
- ISO/TC 199 - Safety of machinery
- Drafting Committee
- ISO/TC 199/WG 11 - Permanent means of access to machinery
- Current Stage
- 9092 - International Standard to be revised
- Start Date
- 17-Dec-2024
- Completion Date
- 14-Feb-2026
Relations
- Effective Date
- 09-Feb-2026
- Referred By
EN ISO 16089:2025 - Machine tools - Safety - Stationary grinding machines (ISO 16089:2025) - Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 09-Feb-2026
- Effective Date
- 12-Feb-2026
- Effective Date
- 06-Jun-2022
- Effective Date
- 07-Jan-2012
- Effective Date
- 07-Jan-2012
Overview
ISO 14122-4:2016 - Safety of machinery - Permanent means of access to machinery - Part 4: Fixed ladders defines minimum safety requirements for fixed ladders that are part of machinery or the building/civil construction when their main function is to provide access to a machine. The standard covers fixed ladders including their non-powered adjustable and movable parts (e.g., foldable, slidable) and is intended to be used together with ISO 14122-1. It applies to stationary and mobile machinery where fixed means of access are necessary, but it is not applicable to powered access (lifts, escalators) or to machinery manufactured before the standard’s publication.
Key topics and technical requirements
ISO 14122-4:2016 addresses practical design, installation and verification matters for safe fixed ladder systems. Major technical topics include:
- Selection and design of ladder systems
- General design and construction principles
- Choice of ladder type based on available space
- Spacing from permanent obstructions
- Fall protection
- Necessity and selection of fall protection devices (safety cages, fall arresters)
- Guidance for risk assessment and limits tied to total ladder height (e.g., sections for >3 000 mm ≤10 000 mm and >10 000 mm)
- Platforms and landings
- Installation at arrival/departure areas
- Requirements for intermediate and rest platforms and landings
- Specific structural requirements
- Load actions: permanent (dead) and variable (rated) loads, additional loading
- Strength and design of ladder elements: stiles, rungs, connections
- Requirements for single-stile and two-stile ladders
- Departure/arrival areas and access openings
- Safe exit/entry arrangements, trap door considerations
- Verification and testing
- Stability verification by calculation or testing
- Tests for ladder strength, bending, safety cages, and guard-rail extensions
- Information for use
- Instruction handbook requirements and marking (especially for ladders with fall arresters)
- Annexes
- Normative guidance on anti-climb devices and informative dimension summaries and changes from prior editions
Practical applications and users
ISO 14122-4 is used to design, specify, validate and maintain safe fixed access to machinery. Typical users include:
- Machine manufacturers specifying built-in access
- Plant designers and integrators planning machinery installation
- Health & safety professionals and regulators setting compliance expectations
- Maintenance and service providers using and inspecting fixed ladders
- Employers and facility managers responsible for worker access safety
Adopting ISO 14122-4 supports compliance with machinery safety best practices, reduces fall risk, and helps document validated designs and testing for fixed ladder systems.
Related standards
- ISO 14122-1 (Choice of fixed means and general requirements)
- ISO 14122-2 (Working platforms and walkways)
- ISO 14122-3 (Stairs, stepladders and guard-rails)
Keywords: ISO 14122-4, fixed ladders, safety of machinery, permanent means of access, fall protection, safety cage, ladder systems, platforms, verification, machine access safety.
Buy Documents
ISO 14122-4:2016 - Safety of machinery -- Permanent means of access to machinery
ISO 14122-4:2016 - Sécurité des machines -- Moyens d'accès permanents aux machines
Get Certified
Connect with accredited certification bodies for this standard

NSF International
Global independent organization facilitating standards development and certification.
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Sponsored listings
Frequently Asked Questions
ISO 14122-4:2016 is a standard published by the International Organization for Standardization (ISO). Its full title is "Safety of machinery — Permanent means of access to machinery — Part 4: Fixed ladders". This standard covers: ISO 14122-4:2016 gives requirements for fixed ladders which are a part of a stationary machine, and to the non-powered adjustable parts (e.g. foldable, slidable) and movable parts of fixed ladder systems. NOTE 1 "Fixed" means of access are those mounted in such a manner (for example, by screws, nuts, welding) that they can only be removed by the use of tools. ISO 14122-4:2016 specifies minimum requirements that also apply when the same means of access is required as the part of the building or civil construction (e.g. fixed ladders) where the machine is installed, on condition that the main function of that part of the construction is to provide a means of access to the machine. NOTE 2 Where no local regulation or standards exists, this part of ISO 14122 may be used also for means of access which are outside the scope of the standard. It is intended that this part of ISO 14122 be used with ISO 14122‑1 to give the requirements for fixed ladder systems. The ISO 14122 series as a whole is applicable to both stationary and mobile machinery where fixed means of access are necessary. It is not applicable to powered means of access such as lifts, escalators, or other devices specially designed to lift persons between two levels. ISO 14122-4:2016 is not applicable to machinery manufactured before the date of its publication.
ISO 14122-4:2016 gives requirements for fixed ladders which are a part of a stationary machine, and to the non-powered adjustable parts (e.g. foldable, slidable) and movable parts of fixed ladder systems. NOTE 1 "Fixed" means of access are those mounted in such a manner (for example, by screws, nuts, welding) that they can only be removed by the use of tools. ISO 14122-4:2016 specifies minimum requirements that also apply when the same means of access is required as the part of the building or civil construction (e.g. fixed ladders) where the machine is installed, on condition that the main function of that part of the construction is to provide a means of access to the machine. NOTE 2 Where no local regulation or standards exists, this part of ISO 14122 may be used also for means of access which are outside the scope of the standard. It is intended that this part of ISO 14122 be used with ISO 14122‑1 to give the requirements for fixed ladder systems. The ISO 14122 series as a whole is applicable to both stationary and mobile machinery where fixed means of access are necessary. It is not applicable to powered means of access such as lifts, escalators, or other devices specially designed to lift persons between two levels. ISO 14122-4:2016 is not applicable to machinery manufactured before the date of its publication.
ISO 14122-4:2016 is classified under the following ICS (International Classification for Standards) categories: 13.110 - Safety of machinery. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 14122-4:2016 has the following relationships with other standards: It is inter standard links to EN ISO 16090-1:2018, EN ISO 16089:2025, EN ISO 10218-2:2025, EN ISO 14122-1:2016, EN ISO 20430:2020, EN ISO 12643-1:2023, EN ISO 22291:2022, EN ISO 16092-1:2018, EN ISO 14122-4:2016, ISO/TS 17892-1:2004, ISO 14122-4:2004/Amd 1:2010, ISO 14122-4:2004. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ISO 14122-4:2016 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 14122-4
Second edition
2016-06-01
Safety of machinery — Permanent
means of access to machinery —
Part 4:
Fixed ladders
Sécurité des machines — Moyens d’accès permanents aux
machines —
Partie 4: Échelles fixes
Reference number
©
ISO 2016
© ISO 2016, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – All rights reserved
Contents Page
Foreword .v
Introduction .vi
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 2
4 Selection and design of ladder systems . 6
4.1 General . 6
4.1.1 Design and construction . 6
4.1.2 Choice depending on available space . 6
4.1.3 Spacing between the ladder and any permanent obstruction . 6
4.2 Choice of a type fall protection device . 7
4.2.1 Necessity of a fall protection device . 7
4.2.2 Types of fall protection devices . 7
4.2.3 Guidance for a risk assessment . 8
4.3 Height of ladder flights and fall protection device . 8
4.3.1 Limits of space . 8
4.3.2 Ladder systems >3 000 mm and ≤10 000 mm total height, H.8
4.3.3 Ladder systems >10 000 mm total height, H .9
4.4 Platforms and landings . 9
4.4.1 Installation of platforms at arrival and departure areas . 9
4.4.2 Arrangement of platforms and landings for ladders with a total height, H
>10 000 mm . 9
5 Specific requirements of ladder systems .10
5.1 General requirements .10
5.1.1 Permanent action (dead load) .10
5.1.2 Variable action (rated load) .11
5.1.3 Additional loading .13
5.1.4 Design .14
5.2 Ladder with two stiles .14
5.2.1 Strength .14
5.2.2 Rungs .14
5.2.3 Connection of ladder and guard-rail .17
5.3 Ladder with one stile .17
5.3.1 Strength .17
5.3.2 Rungs .18
5.4 Departure and arrival areas .19
5.4.1 General requirements .19
5.4.2 Departure area (entrance) .19
5.4.3 Arrival area (exit) .19
5.4.4 Access opening .19
5.4.5 Trap doors .21
5.5 Fall protection device .22
5.5.1 Safety cage .22
5.5.2 Fall arrester .26
5.6 Platforms and landings .26
5.6.1 Access platforms .26
5.6.2 Intermediate and rest platforms .26
5.6.3 Intermediate landings .27
5.6.4 Moveable rest landings . .29
5.7 Requirements on moveable parts of fixed ladders .30
6 Verification of safety requirements .30
6.1 General .30
6.1.1 General requirements .30
6.1.2 Verification of stability by calculation .31
6.1.3 Verification of stability by testing .31
6.2 Tests of fixed ladders with two stiles .31
6.2.1 Strength and bending of a ladder element .31
6.2.2 Test for safety cage .32
6.3 Test of ladders with one stile .33
6.3.1 Test of ladder elements .33
6.4 Test of extensions of guard-rails .35
7 Information for use for fixed ladders .36
7.1 Instruction handbook .36
7.1.1 General.36
7.1.2 Ladder systems with fall arrester .36
7.2 Marking of ladder systems with fall arrester .37
Annex A (normative) Requirements for the design of anti-climb devices .38
Annex B (informative) Summary of main dimensions of a fixed ladder equipped with a
safety cage .42
Annex C (informative) Significant technical changes between this part of ISO 14122 and the
previous edition .44
Bibliography .47
iv © ISO 2016 – All rights reserved
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity
assessment, as well as information about ISO’s adherence to the WTO principles in the Technical
Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information
The committee responsible for this document is ISO/TC 199, Safety of machinery.
This second edition cancels and replaces the first edition (ISO 14122-4:2004), which has been
technically revised. It also incorporates the Amendment ISO 14122-4:2004/Amd 1:2010.
ISO 14122 consists of the following parts, under the general title Safety of machinery — Permanent
means of access to machinery:
— Part 1: Choice of fixed means and general requirements of access
— Part 2: Working platforms and walkways
— Part 3: Stairs, stepladders and guard-rails
— Part 4: Fixed ladders
An additional part, dealing with mobile machinery, is under preparation.
Introduction
This International Standard is a type-B standard as stated in ISO 12100.
This International Standard is of relevance, in particular, for the following stakeholder groups
representing the market players with regard to machinery safety:
— machine manufacturers (small, medium, and large enterprises);
— health and safety bodies (regulators, accident prevention organizations, market surveillance, etc.);
Others can be affected by the level of machinery safety achieved with the means of the International
Standard by the above-mentioned stakeholder groups:
— machine users/employers (small, medium, and large enterprises);
— machine users/employees (e.g. trade unions, organizations for peoples with special needs);
— service providers, e.g. for maintenance (small, medium, and large enterprises);
— consumers (in case of machinery intended for use by consumers).
The above mentioned stakeholder groups have been given the possibility to participate at the drafting
process of this International Standard.
In addition, this International Standard is intended for standardization bodies elaborating type-C
standards.
The requirements of this International Standard can be supplemented or modified by a type-C standard.
For machines which are covered by the scope of a type-C standard and which have been designed and
built according to the requirements of that standard, the requirements of that type-C standard take
precedence.
The purpose of this International Standard is to define the general requirements for safe access to
machines. ISO 14122-1 gives guidance about the correct choice of access means when the necessary
access to the machine is not possible directly from the ground level or from a floor or platform.
The dimensions specified are consistent with established ergonomic data given in ISO 15534-3.
vi © ISO 2016 – All rights reserved
INTERNATIONAL STANDARD ISO 14122-4:2016(E)
Safety of machinery — Permanent means of access to
machinery —
Part 4:
Fixed ladders
1 Scope
This part of ISO 14122 gives requirements for fixed ladders which are a part of a stationary machine,
and to the non-powered adjustable parts (e.g. foldable, slidable) and movable parts of fixed ladder
systems.
NOTE 1 “Fixed” means of access are those mounted in such a manner (for example, by screws, nuts, welding)
that they can only be removed by the use of tools.
This part of ISO 14122 specifies minimum requirements that also apply when the same means of access
is required as the part of the building or civil construction (e.g. fixed ladders) where the machine is
installed, on condition that the main function of that part of the construction is to provide a means of
access to the machine.
NOTE 2 Where no local regulation or standards exists, this part of ISO 14122 may be used also for means of
access which are outside the scope of the standard.
It is intended that this part of ISO 14122 be used with ISO 14122-1 to give the requirements for fixed
ladder systems.
The ISO 14122 series as a whole is applicable to both stationary and mobile machinery where fixed
means of access are necessary. It is not applicable to powered means of access such as lifts, escalators,
or other devices specially designed to lift persons between two levels.
This part of ISO 14122 is not applicable to machinery manufactured before the date of its publication.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 12100, Safety of machinery — General principles for design — Risk assessment and risk reduction
ISO 14122-1:2016, Safety of machinery — Permanent means of access to machinery — Part 1: Choice of
fixed means and general requirements of access
ISO 14122-2:2016, Safety of machinery — Permanent means of access to machinery — Part 2: Working
platforms and walkways
ISO 14122-3:2016, Safety of machinery — Permanent means of access to machinery — Part 3: Stairs,
stepladders and guard-rails
EN 353-1:2014, Personal protective equipment against falls from a height — Part 1: Guided type fall
arresters including a rigid anchor line
EN 795, Personal fall protection equipment — Anchor devices
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 12100, ISO 14122-1, and the
following apply.
3.1
fixed ladder system
ladder system
fixed ladder
installation of at least one ladder flight (3.4), fall protection (3.7), where appropriate, as well as landing(s)
and/or platform(s)
Note 1 to entry: In the following text, the abbreviation “ladder” and “ladder flight” is used for fixed ladders and
fixed ladder flights, respectively.
3.2
ladder with two stiles
ladder, according to ISO 14122-1:2016, 3.1, which is stationary and where the rungs are arranged
between and attached to the stiles
Note 1 to entry: The stiles carry the load (see Figure 1).
Figure 1 — Ladder with two stiles
3.3
ladder with one stile
ladder, according to ISO 14122-1:2016, 3.1, which is stationary and where the rungs are attached to
both sides of the stile
Note 1 to entry: The stile carries the load alone (see Figure 2).
2 © ISO 2016 – All rights reserved
Figure 2 — Ladder with one stile
3.4
ladder flight
continuous part of the fixed ladder (3.1)
— between the departure area (3.8) and arrival area (3.9), in the case of ladders without platforms, or
— between the departure area (3.8) or arrival area (3.9) and the nearest platform, or
— sequentially between landings or rest platforms (3.12)
Note 1 to entry: See Figures 3a and 3b.
3.5
climbing height of ladder system
total height
H
vertical distance between the departure area on the ground and the arrival area (3.9) at the top of a
ladder system (3.1)
Note 1 to entry: See Figure 3 a).
Note 2 to entry: In case of staggered ladder flights (3.4), the vertical distance between departure area (3.8) of the
first flight and the arrival area at the top of the last flight.
3.6
height of ladder flight
h
vertical distance of each staggered ladder flight (3.4)
Note 1 to entry: See Figure 3 b).
a) Single ladder flight b) Staggered ladder flights
Key
1 departure area
2 arrival area
H climbing height of ladder system (total height)
3 intermediate platform or intermediate landing
4 ladder flight
h height of ladder flight
Figure 3 — Height of flights and location of intermediate platforms/landings
3.7
fall protection
technical measure to prevent or to minimize the risk of people falling from ladders
3.7.1
safety cage
cage-shaped protective device, permanently fixed to the ladder, to minimize the risk of persons falling
from ladders
Note 1 to entry: See Figure 14, Figure 15, Figure 20 a) and Figure B.1.
3.7.2
guided type fall arrester on rigid anchorage line
fall arrester
protective equipment permanently fixed to the ladder and used in combination with personal protective
equipment
Note 1 to entry: See also definition in EN 353–1 and EN 363.
3.8
departure area
entrance
bottom level of the surroundings or of the intermediate platform (3.11) from which a person starts to
climb the ladder or ladder system (3.1)
Note 1 to entry: See Figure 3 a) and Figure 3 b).
4 © ISO 2016 – All rights reserved
3.9
arrival area
exit
top level of the surroundings or of the intermediate platform (3.11) to which, the person steps after the
ascent or the descent downwards starts
Note 1 to entry: See Figure 3 a) and Figure 3 b).
Note 2 to entry: In a ladder system with staggered flights, the arrival area (3.9) can also be a departure area (3.8)
for subsequent ascent.
3.10
intermediate landing
horizontal structure between two consecutive ladder flights (3.4), used with ladders having staggered
flights, which is designed to change the ladder flights or for resting
Note 1 to entry: See Figure 20.
3.11
intermediate platform
horizontal structure between two consecutive ladder flights (3.4) which is designed to allow more than
one person at the same time to change or to rest in the ladder system
Note 1 to entry: See Figure 19.
3.12
rest platform
horizontal structure on a single ladder flight (3.4) which is designed to allow more than one person at
same time to rest in the ladder system
Note 1 to entry: See Figure 18.
3.13
moveable rest landing
area equipped with the required protective means designed to incite that the user of the ladder system
(3.1) can rest but cannot interchange
Note 1 to entry: See Figure 21 a) and Figure 21 b).
3.14
access platform
horizontal structure at the departure area (3.8) or arrival area (3.9) used by a person for access to a
ladder system (3.1)
3.15
trap door
hatch, intended to be opened temporarily to provide access through a platform or other horizontal
structure
Note 1 to entry: See Figure 13.
3.16
non-trained user
person without experience how to use the fall arrester
3.17
well-trained user
person with instruction and experience in how to use the fall arrester
EXAMPLE Installer of wind turbine generator systems.
4 Selection and design of ladder systems
4.1 General
4.1.1 Design and construction
Ladder systems are designed with staggered flights or single flight (see 4.3.2 and 4.3.3).
The ladder(s) should be designed with two stiles. In exceptional cases (e.g. insufficient space for
installation a ladder with two stiles or where a fall arrester is required, because of an altering inclination
of the ladder system), ladder(s) with one stile may be foreseen.
4.1.2 Choice depending on available space
Minimum space can be achieved by using single flights (see 4.3.3 for height restrictions for a single
flight).
Medium space is required when using consecutive staggered flights with landings (see Figure 20).
Maximum space is required when staggered flights and intermediate platforms are applied (see
Figure 19).
4.1.3 Spacing between the ladder and any permanent obstruction
The space between the ladder and any permanent obstruction or obstacles shall be (see Figure 4)
a) measured from the front of the rungs:
1) in front of the ladder:
— at least 650 mm or, where obstacles such as pipes or trays cross, 600 mm;
2) behind the ladder:
— at least 200 mm or, where obstacles such as pipes or trays cross, 150 mm.
b) measured from behind of the rungs:
1) behind the ladder:
— at least 75 mm, except the upper rung, which shall be between 60 mm and 75 mm.
If the stiles are designed to be used as a handrail the space around the stiles shall be at least 75 mm,
except at the level at the arrival area.
6 © ISO 2016 – All rights reserved
Dimensions in millimetres
Key
1 arrival area
2 obstacles such as pipes or trays
Figure 4 — Space dimensions with permanent obstacles
4.2 Choice of a type fall protection device
4.2.1 Necessity of a fall protection device
In case of an overall falling height ≥3 000 mm, the ladder shall be fitted with a fall protection device.
4.2.2 Types of fall protection devices
The main alternatives for protection of the users of fixed ladders against falling from a height are the
following:
a) Safety cage
The cage is a means which is always present and the actual level of safety is independent of the
operator’s actions, therefore it is the preferred choice.
b) Guided type fall arrester on rigid anchorage line (fall arrester)
A fall arrester is only effective if the user chooses to use it. If a harness with an incompatible sliding
system is used with a guided type fall arrester, there will be a risk of falling.
A combination of both safety cage and fall arrester, shall not be applied.
4.2.3 Guidance for a risk assessment
For the selection of a suitable type of fall protection device, a risk assessment in accordance with
ISO 12100 shall be made for each particular application and especially when drafting type C- standards.
The relevant aspects to be taken into account are, for example, the following:
a) access conditions, such as
1) range limits, and
2) design limits;
b) total climbing height for a fixed ladder;
c) quantum of risk of falling from height and expected severity of injuries;
d) human aspects, such as
1) fatigue,
2) stress, and
3) experience, ability and training;
e) rescue aspects;
f) environmental aspects, such as
1) wind, and
2) extreme temperatures;
g) frequency of use:
1) occasional, or
2) common;
h) handling of
1) tools, and
2) spare parts.
4.3 Height of ladder flights and fall protection device
4.3.1 Limits of space
Surrounding structures, e.g. walls, parts of machines, can provide protection equivalent to a safety
cage when they provide a containment area with dimensions similar to those given for a safety cage in
5.5.1.2.
4.3.2 Ladder systems >3 000 mm and ≤10 000 mm total height, H
These shall be designed as follows:
— staggered flights with a maximum height of the flight, h, of 6 000 mm, equipped with a safety cage;
— a single flight, equipped with a safety cage;
— a single flight, equipped with a guided type fall arrester on a rigid anchorage line (fall arrester).
8 © ISO 2016 – All rights reserved
Where it is not possible to use a cage, individual protective equipment, e.g. a fall arrester, shall be
provided.
NOTE Fall arresters are intended to be used only by well-trained persons (see Clause 7).
4.3.3 Ladder systems >10 000 mm total height, H
They shall be designed as follows:
— staggered flights with a maximum height of the flight, h, of not more than 6 000 mm equipped either
with a safety cage;
— staggered flights equipped with a fall arrester;
— a single flight be equipped with a fall arrester.
For non-trained users, only staggered flights equipped with a safety cage shall be provided.
Where it is not possible to use a cage, individual protective equipment shall be provided.
NOTE The fall arrester is intended to be used only by well–trained persons (see Clause 7).
4.4 Platforms and landings
4.4.1 Installation of platforms at arrival and departure areas
If the present areas on site at the departure area and arrival area are not built horizontally, solidly and
even, platforms or other means shall be applied to achieve this requirement.
4.4.2 Arrangement of platforms and landings for ladders with a total height, H >10 000 mm
4.4.2.1 General
Where it is intended that more than one person will use the ladder system at the same time, depending
on the type of the fall protection device, intermediate platforms or rest platforms shall be provided (see
4.4.2.2 to 4.4.2.4).
4.4.2.2 Ladders equipped with a safety cage
Intermediate platforms or landings with a distance ≤6 000 mm shall be applied at the change of ladder
systems with staggered flights (see Figure 3b).
4.4.2.3 Ladders equipped with a fall arrester and a total height, H, ≥24 000 mm
Ladders with single flights shall be equipped with rest platforms with distances ≤24 000 mm (see
Figure 5). In between, an additional rest platform with distances ≤12 000 mm shall be fitted (see
Figure 5). In case of insufficient space, moveable rest landings according to 5.6.4 may be fitted.
Ladders with staggered flights shall be equipped with intermediate platforms at intervals ≤24 000 mm
(see Figure 19). In between, additional rest platforms at intervals ≤12 000 mm shall be provided (see
Figure 5). In case of insufficient space, moveable rest landings according to 5.6.4 may be fitted.
4.4.2.4 Ladders equipped with a fall arrester and a total height, H, <24 000 mm
Rest platforms (see Figure 18) at intervals ≤12 000 mm shall be provided. When sufficient space cannot
be made available, moveable rest landings according to 5.6.4 may be provided.
Dimensions in millimetres
Key
1 departure area
2 rest platform
3 intermediate platform
4 arrival area
5 fixed ladder system (schematic drawing)
Figure 5 — Arrangements of platforms and landings on ladders equipped with a fall arrester
5 Specific requirements of ladder systems
5.1 General requirements
The ladder system shall be designed so that the ladder itself and its attachment withstand reasonably
foreseeable static and dynamic conditions. Criteria to be considered are, for example, the following:
— weight of the ladder system;
— maximum number of person staying in the ladder system;
— additional action occurring when the fall arrester will be activated.
If no other action/loads are relevant the, actions in 5.1.1 to 5.1.3 shall be applied.
5.1.1 Permanent action (dead load)
The mass of every component of the ladder shall be taken into account.
10 © ISO 2016 – All rights reserved
5.1.2 Variable action (rated load)
Loads F = 1,5 kN and F = 1,5 kN (see Figure 6) shall be used during the design of a ladder to represent
1 2
a person.
The simulated load for the rungs F (see Figure 6 a) and b) for a person shall be applied perpendicular to
the rung at the most unfavourable position and equally distributed over a maximum length of 100 mm.
The simulated loads for the stile(s) F shall be applied with a separation distance of 2 000 mm and
parallel to the longitudinal axis of the ladder. The distance between the loads F and the stile(s) shall be
300 mm [see Figure 6 c)].
For ladders with two stiles, the load F shall be taken to be shared equally by both stiles [see Figure 6 c)].
For platforms and landings as specified in 5.6, a concentrated load of 1,5 kN per person, applied at the
most unfavourable position, shall be taken in to account.
For platforms, intermediate landings and moveable rest landings (one part) [see Figure 21 a)],
concentrated loads are loads distributed over a load area of 200 mm × 200 mm.
For moveable rest landings (two parts) [see Figure 21 b)], concentrated loads are loads distributed over
two load areas, each of 100 mm × 100 mm.
Platforms shall be designed in accordance with ISO 14122-2 and ISO 14122-3.
Dimensions in millimetres
a) Simulated loads on rungs for ladders with b) Simulated loads on rungs for ladders with
two stiles one stile
c) Simulated loads for stiles (schematic drawing)
Key
F simulated load for rungs
F simulated load for stiles
Figure 6 — Simulated loads on the ladder
12 © ISO 2016 – All rights reserved
5.1.3 Additional loading
5.1.3.1 General
Additional loading, e.g. caused by wind or snow, fall protection devices (see 5.1.3.2 and 5.1.3.3) shall be
taken into account in stability calculations.
Loading on ladders, e.g. by impacts of trucks, is normally not considered.
5.1.3.2 Fall arrester
Calculations shall take into account the loading on the anchor line and the ladder when the fall
protection device is activated by a falling person. In the absence of actual data, a minimum vertical
force of 6 kN shall be assumed.
5.1.3.3 Safety cage
For the design of the safety cage, as a minimum the test procedure of 6.2.2 shall be applied.
5.1.3.4 Ladder anchorage system
Calculations shall take into account a minimum load of ≥3 kN acting on each stile for ladders with two
stiles, and a load of ≥6 kN acting on the single stile of ladders with one stile.
For calculation, it may be assumed that the load will be transmitted to fixed parts of surroundings (e.g.
wall or enclosure of the machine) by four anchorage points
a) Ladder with two stiles b) Ladder with one stile
Key
1 rung
2 stile
3 mounting
4 anchor point
5 fixed part (e.g. wall)
Figure 7 — Arrangements of anchor points and connections
5.1.4 Design
Ladders shall be designed to meet the same installation requirements as the machine, taking into
account, where necessary, conditions such as harsh environment or vibrations.
All parts likely to be in contact with users shall be designed so that persons are not caught, hurt (e.g.
caused by sharp corners, edges, welds with burrs) or hindered.
Opening or closing of moveable parts (gate) shall not cause hazards, e.g. accidental falling or shearing.
Fittings, hinges, anchor points, supports, and mounting points shall keep the assembly sufficiently rigid
and stable to ensure the safety of users under normal conditions of use.
5.2 Ladder with two stiles
5.2.1 Strength
Ladder elements shall meet the verification requirement of stability by calculation in 6.1 or by test in 6.2.
5.2.2 Rungs
5.2.2.1 Strength
Rungs shall meet the verification requirement of stability by calculation in 6.1 or by test in 6.2.
5.2.2.2 Spacing
With the exception of the requirements for spacing between rungs at the departure area (see 5.4.2 and
Figure 8), the spacing between successive rungs, A, shall be constant and shall be between 225 mm
and 300 mm.
14 © ISO 2016 – All rights reserved
Dimension in millimetres
•
Key
A spacing
Figure 8 — Spacing and length of rungs
5.2.2.3 Length of rungs
The clear width between the two stiles shall be between 400 mm and 600 mm (see Figure 8). However,
a clear width between 300 mm and 400 mm is permissible, in cases where the immediate environment
makes it impossible to use 400 mm. Before a lower clear width is considered a check shall be carried
out to see if it is possible to find a more favourable position for the ladder allowing a clear width of
400 mm or more.
When using a fall arrester the clear width between the stiles and the rigid anchorage line for a guided
type fall arrester shall be at least 150 mm and the thickness of the anchorage line shall not be more
than 80 mm (see Figure 9).
A A
Dimension in millimetres
Figure 9 — Length of rungs on a ladder with two stiles and a rigid anchorage line for a fall
arrester
5.2.2.4 Shape of rungs
The tread walking surface shall be flat and ≥20 mm [see Figure 10 a) to c)]. Therefore, circular rungs
are not permitted. As an exception an inclined walking surface in accordance with Figure 10 d) is
permitted.
The total perimeter of closed rungs, e.g. square, rectangular, polygonal, or inclined, shall be ≤140 mm.
Open rungs such as U-shaped rungs which cannot be fully gripped shall be designed such that injury to
the hand from sharp edges is avoided.
For fixed ladders without fall protection devices, low climbing height and additionally an enhanced
degree of pollution from the environment, slip resistant large rungs with for example two-row or
multiple-row embossing perforation, can be used.
Special measures to prevent slipping may be necessary when the risk of slipping is increased due to
environmental conditions (oil, ice, etc.). Where the accumulation of, for example, snow, ice, or dust is
present, rungs with inclined profile according to Figure 10 d) may be used.
The surface of the rung shall have a slip resistant walking surface which causes no injuries, to hands.
Until an International Standard on enhanced slip resistance is available, see ISO 14122-2:2016, Annex A.
5.2.2.5 Position of rungs
Rungs shall be positioned so that their tread walking surface is perpendicular to axis of the stile (see
Figure 10).
16 © ISO 2016 – All rights reserved
Dimension in millimetres
a) Design of rectangular rungs — b) Design of polygonal rungs — mounting for
recommended mounting special use only
c) Design of U-shaped profile rungs— d) Design of rungs with inclined profile
recommended mounting
Key
1 tread walking surface
2 no sharp edges
3 rung
Figure 10 — Examples of position and shape of rungs
5.2.3 Connection of ladder and guard-rail
If the distance between ladder and guard-rail is >120 mm, then the guard-rail shall be fitted
connecting with the ladder in the range of the handrails and kneerails. For further information, see
ISO 14122-3:2016, 7.1.
5.3 Ladder with one stile
5.3.1 Strength
The ladder shall meet the tests in 6.3 (torsion test).
5.3.2 Rungs
5.3.2.1 Strength
Rungs shall meet the verification requirement of stability by calculation in 5.1 or by test in 6.3.
5.3.2.2 Spacing
The spacing shall be in accordance with 5.2.2.2. The rung at one side of the stile shall be on the same
level as the respective rung at the opposite side of the stile (see Figure 11).
Dimension in millimetres
Key
1 departure area
2 arrival area
Figure 11 — Dimensions and design of a ladder with one stile and a rigid anchorage line
5.3.2.3 Cross-section, tread, and position of rungs
The requirements of 5.2.2.4 and 5.2.2.5 shall be applied.
5.3.2.4 Length of rungs
The clear width between the stile and the protective device against slipping-off shall be ≥150 mm and
≤250 mm and the width of the stile shall be ≤80 mm (see Figure 11).
The ends of the rungs shall be fitted with protective devices against slipping-off laterally from the rungs.
These protective devices against slipping-off shall have a height of ≥20 mm (see detail X of Figure 11).
18 © ISO 2016 – All rights reserved
5.4 Departure and arrival areas
5.4.1 General requirements
If it is required to take measures to prevent unauthorized people and/or persons not fully equipped
with a fall arrester and non-trained persons to gain access to machinery, an “anti-climb” device as
specified in Annex A shall be applied when such equipment is fitted on the ladder. In this case, a written
warning or audible signal is not alone an adequate a device for access control.
Measures to prevent persons falling from a height shall be provided, e.g. guard-rails, over a length of at
least 1 500 mm, at the following:
— on both the left and the right sides of the vertical axis of the ladder;
— over the entire length of the edge, if the length on both sides is less than 1 500 mm (entire length of
the edge less than 3 000 mm);
— on both sides of adjacent walkways.
These measures to prevent persons falling from height are independent from any fall protection device
on the ladder.
When a fall arrester is applied, connecting or disconnecting with this device shall only be possible from
a safe area/position.
Departure and arrival areas as well as intermediate platforms shall meet the relevant requirements of
ISO 14122-2 and ISO 14122-3.
5.4.2 Departure area (entrance)
If the walking surface of the departure area has been raised by more than 500 mm above the
surroundings, or the departure area is close to areas which are not able to take a load, e.g. area made of
glass or synthetic material, the departure area shall have guard-rails or equivalent means that are able
to protect persons against falling from a height.
The spacing between departure area and lowest rung shall be ≥100 mm and ≤400 mm (see Figure 8).
5.4.3 Arrival area (exit)
At the arrival area a platform according ISO 14122-2 and ISO 14122-3 shall be provided.
If a structure of the machine or part of the building is considered
...
NORME ISO
INTERNATIONALE 14122-4
Deuxième édition
2016-06-01
Sécurité des machines — Moyens
d’accès permanents aux machines —
Partie 4:
Échelles fixes
Safety of machinery — Permanent means of access to machinery —
Part 4: Fixed ladders
Numéro de référence
©
ISO 2016
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2016, Publié en Suisse
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – Tous droits réservés
Sommaire Page
Avant-propos .v
Introduction .vi
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 2
4 Sélection et conception des systèmes d’échelles . 6
4.1 Généralités . 6
4.1.1 Conception et construction. 6
4.1.2 Choix en fonction de l’espace disponible . 6
4.1.3 Dégagement entre l’échelle et les parties fixes de la zone environnant le
moyen d’accès . 6
4.2 Choix du type de dispositif de protection contre les chutes . 7
4.2.1 Nécessité d’utiliser un dispositif de protection contre les chutes . 7
4.2.2 Types de dispositif de protection contre les chutes . 7
4.2.3 Lignes directrices pour l’appréciation du risque . 8
4.3 Hauteur des volées d’échelles du dispositif de protection contre les chutes . 8
4.3.1 Limites en matière d’espace. 8
4.3.2 Systèmes d’échelles d’une hauteur totale, H > 3 000 mm et ≤ 10 000 mm . 8
4.3.3 Systèmes d’échelles d’une hauteur totale, H > 10 000 mm . 9
4.4 Plates-formes et paliers . 9
4.4.1 Installation des plates-formes sur les aires de départ et d’arrivée . 9
4.4.2 Disposition des plates-formes et des paliers pour les échelles d’une
hauteur totale, H > 10 000 mm . 9
5 Exigences spécifiques applicables aux systèmes d’échelles .10
5.1 Exigences générales .10
5.1.1 Action permanente (poids propre) .11
5.1.2 Action variable (charge nominale) .11
5.1.3 Chargement supplémentaire .13
5.1.4 Conception .14
5.2 Échelle à deux montants .14
5.2.1 Résistance .14
5.2.2 Échelons .14
5.2.3 Raccordement de l’échelle au garde-corps .17
5.3 Échelle à un seul montant .17
5.3.1 Résistance .17
5.3.2 Échelons .18
5.4 Aires de départ et d’arrivée .19
5.4.1 Exigences générales .19
5.4.2 Aire de départ (entrée) .19
5.4.3 Aire d’arrivée (sortie) .19
5.4.4 Ouverture d’accès .19
5.4.5 Trappes .21
5.5 Dispositif de protection contre les chutes .22
5.5.1 Crinoline .22
5.5.2 Antichute .26
5.6 Plates-formes et paliers .26
5.6.1 Plates-formes d’accès.26
5.6.2 Plates-formes intermédiaires et de repos .27
5.6.3 Paliers intermédiaires .27
5.6.4 Paliers de repos mobiles .29
5.7 Exigences relatives aux parties mobiles des échelles fixes .30
6 Vérification des exigences de sécurité .30
6.1 Généralités .30
6.1.1 Exigences générales .30
6.1.2 Vérification de la stabilité par calcul .31
6.1.3 Vérification de la stabilité par essai .31
6.2 Essais des échelles fixes à deux montants .31
6.2.1 Résistance et flexion d’un élément d’échelle .31
6.2.2 Essai pour la crinoline . .32
6.3 Essai des échelles à un seul montant .33
6.3.1 Essai des éléments d’échelle .33
6.4 Essai des extensions des garde-corps .35
7 Informations d’utilisation des échelles fixes .36
7.1 Notice d’instruction .36
7.1.1 Généralités .36
7.1.2 Systèmes d’échelle avec antichute .36
7.2 Marquage des systèmes d’échelles avec antichute .37
Annexe A (normative) Exigences sur la conception des dispositifs anti-intrusion(anti-escalade) .38
Annexe B (informative) Sommaires des principales dimensions pour une échelle fixe
équipée d’une crinoline .42
Annexe C (informative) Modifications techniques significatives entre la présente partie de
l’ISO 14122 et la précédente édition .44
Bibliographie .47
iv © ISO 2016 – Tous droits réservés
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www.
iso.org/directives).
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www.iso.org/brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la signification des termes et expressions spécifiques de l’ISO liés à
l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion de l’ISO aux principes
de l’OMC concernant les obstacles techniques au commerce (OTC), voir le lien suivant: Avant-propos —
Informations supplémentaires.
Le comité chargé de l’élaboration du présent document est l’ISO/TC 199, Sécurité des machines.
Cette deuxième édition annule et remplace la première édition (ISO 14122-4:2004), dont elle constitue
une révision technique. Elle contient également l’Amendement ISO 14122-4:2004/Amd 1:2010.
L’ISO 14122 comprend les parties suivantes, présentées sous le titre général Sécurité des machines —
Moyens d’accès permanents aux machines:
— Partie 1: Choix d’un moyen d’accès fixe entre deux niveaux
— Partie 2: Plates-formes de travail et passerelles
— Partie 3: Escaliers, échelles à marches et garde-corps
— Partie 4: Échelles fixes
Une additionnelle partie traitant des machines mobiles est en préparation.
Introduction
La présente Norme internationale est une norme de type B tel que stipulé dans l’ISO 12100.
La présente Norme internationale est destinée en particulier aux groupes de parties prenantes suivants,
qui représentent les acteurs du marché en matière de sécurité des machines:
— les fabricants de machines (petites, moyennes et grandes entreprises);
— les organismes d’hygiène et de sécurité (autorités réglementaires, organismes de prévention des
accidents, surveillance du marché, etc.).
D’autres personnes peuvent être concernées par le niveau de sécurité des machines obtenu par
l’intermédiaire des moyens mis en œuvre dans la présente Norme internationale par les groupes de
parties prenantes mentionnés ci-dessus:
— les utilisateurs de machines/employeurs (petites, moyennes et grandes entreprises);
— les utilisateurs de machines/employés (par exemple syndicats, organisations de personnes ayant
des besoins spécifiques);
— les prestataires de services, par exemple pour la maintenance (petites, moyennes et grandes
entreprises);
— les consommateurs (s’il est prévu que la machine soit utilisée par des consommateurs).
Les groupes de parties prenantes mentionnés ci-dessus ont eu la possibilité de participer à l’élaboration
de la présente Norme internationale.
La présente Norme internationale est en outre destinée aux organismes de normalisation élaborant des
normes de type C.
Les exigences de la présente Norme internationale peuvent être complétées ou modifiées par une
norme de type C.
Pour les machines couvertes par le domaine d’application d’une norme de type C et qui ont été conçues
et construites suivant les exigences de cette norme, les exigences de ladite norme de type C sont
prioritaires.
L’objet de la présente Norme internationale est de définir les exigences générales de sécurité d’accès aux
machines. L’ISO 14122-1 donne des lignes directrices concernant le choix approprié des moyens d’accès
lorsque l’accès nécessaire à la machine n’est pas directement possible à partir du niveau du sol, d’un
plancher ou d’une plateforme.
Les dimensions spécifiées sont compatibles avec les données ergonomiques établies dans l’ISO 15534-3.
vi © ISO 2016 – Tous droits réservés
NORME INTERNATIONALE ISO 14122-4:2016(F)
Sécurité des machines — Moyens d’accès permanents aux
machines —
Partie 4:
Échelles fixes
1 Domaine d’application
La présente partie de l’ISO 14122 donne les exigences pour les échelles fixes qui font partie intégrante
d’une machine fixe et aux parties réglables non-motorisées (par exemple pliables, coulissantes) ainsi
qu’aux parties mobiles de ces systèmes d’échelles fixes.
NOTE 1 Les moyens d’accès «fixes» sont ceux montés de telle manière (par exemple par boulonnage, par
soudage) qu’ils ne puissent être démontés qu’à l’aide d’outils.
La présente partie de l’ISO 14122 spécifie les exigences minimales s’appliquant également aux moyens
d’accès fixes aux parties du bâtiment ou de la construction civile (par exemple échelles fixes) où la
machine est installée, à condition que la fonction principale de cette partie de la construction soit de
donner accès à la machine.
NOTE 2 Lorsqu’aucune norme nationale ou réglementation n’existe, la présente partie de l’ISO 14122 peut être
utilisée pour les moyens d’accès en dehors de son domaine d’application.
Il est prévu que la présente partie de l’ISO 14122 soit utilisée conjointement avec l’ISO 14122-1 pour
donner les exigences relatives aux systèmes d’échelles fixes.
L’ensemble de la série ISO 14122 est applicable aux machines fixes et mobiles pour lesquelles des moyens
d’accès fixes sont nécessaires. Cette série n’est pas applicable aux moyens d’accès motorisés tels que
les ascenseurs, les escalators, ou d’autres dispositifs conçus spécialement pour soulever des personnes
entre deux niveaux.
La présente partie de l’ISO 14122 n’est pas applicable aux machines fabriquées avant sa date de
publication.
2 Références normatives
Les documents suivants, en tout ou partie, sont référencés de façon normative dans le présent document
et sont indispensables à son application. Pour les références datées, seule l’édition citée s’applique.
Pour les références non datées, la dernière édition du document de référence s’applique (y compris les
éventuels amendements).
ISO 12100, Sécurité des machines — Principes généraux de conception — Appréciation du risque et
réduction du risque
ISO 14122-1:2016, Sécurité des machines — Moyens d’accès permanents aux machines — Partie 1: Choix
d’un moyen d’accès fixe entre deux niveaux
ISO 14122-2:2016, Sécurité des machines — Moyens d’accès permanents aux machines — Partie 2: Plates-
formes de travail et passerelles
ISO 14122-3:2016, Sécurité des machines — Moyens d’accès permanents aux machines — Partie 3:
Escaliers, échelles à marches et garde-corps
EN 353-1:2014, Équipement de protection individuelle contre les chutes de hauteur — Antichutes mobiles
incluant un support d’assurage — Partie 1: Antichutes mobiles incluant un support d’assurage rigide
EN 795, Protection contre les chutes de hauteur — Dispositifs d’ancrage — Exigences et essais
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions donnés dans l’ISO 12100, l’ISO 14122-1
ainsi que les suivants s’appliquent.
3.1
système d’échelles fixes
système d’échelles
échelle fixe
installation composée d’au moins une volée d’échelle (3.4), de protections contre les chutes (3.7), le cas
échéant, et de paliers et/ou plates-formes
Note 1 à l’article: Dans le reste du texte, les expressions abrégées « échelle » et « volée d’échelle » sont utilisées
pour désigner les échelles fixes et les volées d’échelles fixes, respectivement.
3.2
échelle à deux montants
échelle, conforme à l’ISO 14122-1:2016, 3.1, qui est fixe et dont les échelons sont disposés entre les deux
montants auxquels ils sont attachés.
Note 1 à l’article: Les montants supportent la charge (voir Figure 1).
Figure 1 — Échelle à deux montants
3.3
échelle à un seul montant
échelle, conforme à l’ISO 14122-1:2016, 3.1, qui est fixe et dont les échelons sont attachés de part et
d’autre du montant.
Note 1 à l’article: Le montant supporte seul la charge (voir Figure 2).
2 © ISO 2016 – Tous droits réservés
Figure 2 — Échelle à un seul montant
3.4
volée d’échelle
partie continue d’une échelle fixe (3.1):
— entre l’aire de départ (3.8) et l’aire d’arrivée (3.9) dans le cas des échelles sans plates-formes; ou
— entre l’aire de départ (3.8) ou l’aire d’arrivée (3.9) et la plate-forme la plus proche; ou
— entre deux paliers ou plates-formes de repos successifs (3.12)
Note 1 à l’article: Voir Figures 3a et 3b.
3.5
hauteur de volée d’un système d’échelles
hauteur totale
H
distance verticale totale entre l’aire de départ au sol et l’aire d’arrivée (3.9) supérieure au sommet d’un
système d’échelles (3.1)
Note 1 à l’article: Voir Figure 3 a).
Note 2 à l’article: En cas de volées d’échelles décalées (3.4), la distance verticale entre l’aire de départ (3.8) de la
première volée et l’aire d’arrivée au sommet de la dernière volée.
3.6
hauteur d’une volée d’échelle
h
distance verticale entre chaque volée d’échelle décalée (3.4)
Note 1 à l’article: Voir Figure 3 b).
a) Volée d’échelle unique b) Volées d’échelles décalées
Légende
1 aire de départ
2 aire d’arrivée
H hauteur de volée d’un système d’échelles (hauteur totale)
3 plate-forme ou palier intermédiaire
4 volée d’échelle
h hauteur d’une volée d’échelle
Figure 3 — Hauteur des volées et emplacement des plates-formes/paliers intermédiaires
3.7
dispositif antichute
moyen technique pour prévenir ou réduire le risque de chute de personnes depuis les échelles
3.7.1
crinoline
dispositif de protection en forme de cage, fixé à l’échelle de façon permanente, pour réduire le risque de
chute de personnes depuis les échelles
Note 1 à l’article: Voir Figure 14, Figure 15 et Figure 20 a).
3.7.2
antichute mobile sur support d’assurage rigide
antichute
équipement de protection fixé à l’échelle de façon permanente et utilisé en combinaison avec un
équipement de protection individuelle
Note 1 à l’article: Voir également la définition de l’EN 353–1 et de l’EN 363.
3.8
aire de départ
entrée
plus bas niveau de l’environnement ou du palier intermédiaire (3.11) duquel une personne se déplace
pour aborder la montée à l’échelle ou au système d’échelle (3.1)
Note 1 à l’article: Voir Figure 3 a) et Figure 3 b).
4 © ISO 2016 – Tous droits réservés
3.9
aire d’arrivée
sortie
plus haut niveau de l’environnement ou de la plate-forme intermédiaire (3.11) duquel une personne se
déplace après la montée ou duquel la descente commence
Note 1 à l’article: Voir Figure 3 a) et Figure 3 b).
Note 2 à l’article: Dans un système d’échelle avec des volées décalées, l’aire d’arrivée (3.9) peut également être une
aire de départ (3.8) pour la montée suivante.
3.10
palier intermédiaire
structure horizontale entre deux volées consécutives d’une volée d’échelle (3.4), utilisée avec des
échelles à volées décalées, qui est conçue pour changer de volée d’échelle ou se reposer
Note 1 à l’article: Voir Figure 20.
3.11
plate-forme intermédiaire
structure horizontale entre deux volées consécutives d’une volée d’échelle (3.4), conçue pour permettre
à plusieurs personnes en même temps de se croiser ou de se reposer sur le système d’échelles
Note 1 à l’article: Voir Figure 19.
3.12
plate-forme de repos
structure horizontale sur une volée d’échelle (3.4) simple, conçue pour permettre à plusieurs personnes
de se reposer sur le système d’échelles
Note 1 à l’article: Voir Figure 18.
3.13
Palier de repos mobile
surface équipée avec les moyens de protection nécessaires, conçue pour inciter l’utilisateur du système
d’échelles (3.1) à se reposer physiquement, mais ne permet pas de croiser d’autres personnes
Note 1 à l’article: Voir Figure 21 a) et Figure 21 b).
3.14
plate-forme d’accès
structure horizontale sur l’aire de départ (3.8) ou l’aire d’arrivée (3.9) utilisée par une personne comme
moyen d’accès à un système d’échelles (3.1)
3.15
trappe
dispositif, destiné à être ouvert temporairement pour fournir un accès à travers une plate-forme ou
d’autres structures horizontales
Note 1 à l’article: Voir Figure 13.
3.16
utilisateur non entraîné
personne n’ayant aucune expérience sur la manière d’utiliser l’antichute
3.17
utilisateur bien entraîné
personne ayant reçu des instructions et possédant l’expérience nécessaire pour utiliser l’antichute
EXEMPLE Installateur d’éolienne.
4 Sélection et conception des systèmes d’échelles
4.1 Généralités
4.1.1 Conception et construction
Les systèmes d’échelles sont composés de volées décalées ou d’une volée unique (voir 4.3.2 et 4.3.3).
Il convient que le(s) échelle(s) soi(en)t conçue(s) avec deux montants. Dans des cas exceptionnels (par
exemple espace insuffisant pour l’installation d’une échelle avec deux montants ou lorsqu’un antichute
est requis, en raison d’un angle d’inclinaison variable du système d’échelles), une/des échelles à un seul
montant peut/peuvent être prévue(s).
4.1.2 Choix en fonction de l’espace disponible
L’utilisation de volées uniques permet d’occuper un espace minimal (voir 4.3.3 pour les restrictions de
hauteur d’une volée unique).
L’espace requis est moyennement important en cas d’implantation de volées décalées consécutives avec
des paliers (voir Figure 20).
L’espace requis est maximal en cas d’utilisation de volées décalées et de plates-formes intermédiaires
(voir Figure 19).
4.1.3 Dégagement entre l’échelle et les parties fixes de la zone environnant le moyen d’accès
Le dégagement entre l’échelle et les parties fixes de la zone environnant le moyen d’accès ou les obstacles
doit être (voir Figure 4):
a) mesuré depuis la face avant des échelons:
1) devant l’échelle:
— d’au moins 650 mm ou, en cas de passage perpendiculaire d’obstacles tel que des tuyaux ou
de conduites, 600 mm;
2) derrière l’échelle:
— d’au moins 200 mm ou, en cas de passage perpendiculaire d’obstacles tel que des tuyaux ou
de conduites, 150 mm.
b) mesuré depuis derrière les échelons:
1) derrière l’échelle:
— d’au moins 75 mm, sauf pour l’échelon le plus haut, qui doit être entre 60 mm et 75 mm.
Si les montants sont conçus pour être utilisés comme une poignée, l’espace autour des montants doit
être d’au moins 75 mm, sauf au niveau de l’aire d’arrivée.
6 © ISO 2016 – Tous droits réservés
Dimensions en millimètres
Légende
1 aire d’arrivée
2 obstacles tels que tuyaux ou conduites
Figure 4 — Dimensions des dégagements en présence d’obstacles permanents
4.2 Choix du type de dispositif de protection contre les chutes
4.2.1 Nécessité d’utiliser un dispositif de protection contre les chutes
En cas de hauteur de chute totale ≥ 3 000 mm, l’échelle doit être munie d’un dispositif de protection
contre les chutes.
4.2.2 Types de dispositif de protection contre les chutes
Les principales solutions pour la protection des utilisateurs d’échelles contre les chutes de hauteur sont
les suivantes:
a) Une crinoline
Une crinoline est un moyen de protection toujours présent et dont le niveau réel de sécurité est
indépendant des actions de l’opérateur, qui représente le meilleur choix.
b) Un antichute mobile sur support d’assurage rigide (antichute)
Un antichute est efficace uniquement si l’utilisateur choisit de l’utiliser. Si un harnais avec un
système coulissant non compatible est utilisé avec un antichute mobile, il y aura un risque de chute.
La combinaison de la crinoline et de l’antichute ne doit pas être utilisée.
4.2.3 Lignes directrices pour l’appréciation du risque
Pour le choix d’un type de dispositif de protection contre les chutes adapté, une appréciation du risque
doit être réalisée conformément à l’ISO 12100 pour chaque application spécifique, et particulièrement
lors de la rédaction de normes de type C. Les aspects pertinents à prendre en compte sont, par exemple,
les suivants:
a) conditions d’accès, telles que
2) limitations dimensionnelles, et
3) limitations en matière de conception;
b) hauteur de montée totale d’une échelle fixe;
c) rapport entre le risque de chute de hauteur et la gravité prévisible des blessures;
d) aspects humains, tels que
1) fatigue,
2) stress,
3) expérience, aptitude et formation;
ce) aspects liés au sauvetage;
f) aspects environnementaux, tels que
1) vent, et
2) températures extrêmes;
g) fréquence d’utilisation:
1) occasionnelle, ou
2) régulière;
h) la manipulation
1) d’outils, et
2) de pièces.
4.3 Hauteur des volées d’échelles du dispositif de protection contre les chutes
4.3.1 Limites en matière d’espace
Les structures environnantes, telles que les murs, les parties de machine, peuvent fournir une
protection équivalente à celle d’une crinoline lorsqu’elles fournissent une zone de confinement dont les
dimensions sont similaires à celles données pour une crinoline au 5.5.1.2.
4.3.2 Systèmes d’échelles d’une hauteur totale, H > 3 000 mm et ≤ 10 000 mm
Ces systèmes peuvent être conçus comme suit:
— sous la forme de volées décalées d’une hauteur maximale de volée, h, de 6 000 mm, munie d’une
crinoline;
— sous la forme d’une volée unique, munie d’une crinoline, ou
8 © ISO 2016 – Tous droits réservés
— sous la forme d’une volée unique, munie d’un antichute mobile sur support d’assurage rigide
(antichute).
Lorsqu’il n’est pas possible d’utiliser une crinoline, un équipement de protection individuelle, par
exemple un antichute, doit être fourni.
NOTE L’antichute est destiné à être utilisé par des personnes bien entrainées (voir Article 7).
4.3.3 Systèmes d’échelles d’une hauteur totale, H > 10 000 mm
Ces systèmes doivent être conçus comme suit:
— sous la forme de volées décalées d’une hauteur maximale de volée, h, ne dépassant pas 6 000 mm,
munie d’une crinoline;
— sous la forme de volées décalées munies d’un antichute;
— sous la forme d’une volée unique muni d’un antichute.
En présence de personnes non entraînées, seules des volées décalées munies de crinoline doivent être
utilisées.
Lorsqu’il n’est pas possible d’utiliser une crinoline, un équipement de protection individuelle doit
être fourni.
NOTE L’antichute est destiné à être utilisé par des personnes bien entrainées (voir Article 7).
4.4 Plates-formes et paliers
4.4.1 Installation des plates-formes sur les aires de départ et d’arrivée
Si les surfaces présentes sur le site au niveau des aires de départ et d’arrivée ne sont pas horizontales,
solides et régulières, des plates-formes ou d’autres moyens doivent être utilisées afin d’être en
conformité avec la présente exigence.
4.4.2 Disposition des plates-formes et des paliers pour les échelles d’une hauteur totale, H
> 10 000 mm
4.4.2.1 Généralités
Lorsqu’il est prévu que plusieurs personnes utiliseront le système d’échelles en même temps, selon
le type de dispositif de protection contre les chutes, des plates-formes intermédiaires ou des plates-
formes de repos doivent être fournies (voir 4.4.2.2 à 4.4.2.4).
4.4.2.2 Echelles munies de crinoline
Des plates-formes ou paliers intermédiaires doivent être installées sur une distance de ≤ 6 000 mm au
changement de volée des systèmes d’échelles comportant des volées décalées (voir Figure 3b).
4.4.2.3 Echelles munies d’un antichute et d’une hauteur totale, H ≥ 24 000 mm
Les échelles avec volées uniques doivent être munies de plates-formes de repos installées sur des
distances ≤ 24 000 mm (voir Figure 5). Entre ces plates-formes de repos, une plate-forme de repos
supplémentaire peut être installée sur des distances ≤ 12 000 mm (voir Figure 5). Si l’espace est
insuffisant, des paliers de repos mobiles peuvent être installés, conformément au 5.6.4.
Les échelles avec des volées décalées doivent être munies de plates-formes intermédiaires installées à
des intervalles ≤ 24 000 mm (voir Figure 19). Entre ces plates-formes intermédiaires, des plates-formes
de repos peuvent être installées à des intervalles ≤ 12 000 mm (voir Figure 5). Si l’espace est insuffisant,
des paliers de repos mobiles peuvent être installés, conformément au 5.6.4.
4.4.2.4 Echelles munies d’un antichute et d’une hauteur totale, H < 24 000 mm
Des plates-formes de repos (voir Figure 18) doivent être installées à des intervalles ≤ 12 000 mm. Si
l’espace est insuffisant, des paliers de repos mobiles peuvent être installés, conformément au 5.6.4.
Dimensions en millimètres
Légende
1 aire de départ
2 plate-forme de repos
3 plate-forme intermédiaire
4 aire d’arrivée
5 système d’échelles fixes (dessin schématique)
Figure 5 — Dispositions des plates-formes et paliers sur des échelles munies d’un antichute
5 Exigences spécifiques applicables aux systèmes d’échelles
5.1 Exigences générales
Le système d’échelles doit être conçu de sorte que l’échelle proprement dite et ses accessoires résistent
à des conditions statiques et dynamiques raisonnablement prévisibles. Les critères à prendre en
considération sont, par exemple, les suivants:
— le poids du système d’échelles;
— le nombre maximal de personnes présentes sur le système d’échelles;
10 © ISO 2016 – Tous droits réservés
— l’action supplémentaire se produisant lorsqu’un antichute est activé.
Si aucune autre action/charge n’est pertinente, les actions décrites du 5.1.1 au 5.1.3 doivent être
appliquées.
5.1.1 Action permanente (poids propre)
La masse de chaque composant de l’échelle doit être prise en compte.
5.1.2 Action variable (charge nominale)
Les charges F = 1,5 kN et F = 1,5 kN (voir Figure 6) doivent être utilisées pour représenter le poids
1 2
d’une personne lors de la conception de l’échelle.
La charge simulée pour les échelons F (voir Figure 6 a) et b) pour une personne doit être appliquée
perpendiculairement à l’échelon, dans la position la plus défavorable, et doit être répartie uniformément
sur une longueur maximale de 100 mm.
Les charges simulées pour le(s) montant(s) F doivent être appliquées parallèlement à l’axe longitudinal
de l’échelle avec une distance de séparation de 2 000 mm. La distance entre les charges F et le(s)
montant(s) doit être de 300 mm [voir Figure 6 c)].
Pour les échelles à deux montants, la charge F doit être répartie équitablement entre chaque montant
[voir Figure 6 c)].
Pour les plates-formes et paliers tels que spécifiés au 5.6, une charge concentrée de 1,5 kN par personne,
appliquée à la position la plus défavorable, doit être prise en compte.
Pour les plates-formes, les paliers intermédiaires et les paliers de repos mobiles (une partie) [voir
Figure 21 a)], les charges concentrées sont des charges distribuées sur une zone de chargement de
200 mm × 200 mm.
Pour les paliers de repos mobiles (deux parties) [voir Figure 21 b)], les charges concentrées sont des
charges distribuées sur deux zones de chargement, de chacune 100 mm × 100 mm.
Les plates-formes plus larges doivent être conçues conformément aux ISO 14122-2 et ISO 14122-3.
Dimensions en millimètres
a) Charges simulées sur les échelons pour les b) Charges simulées sur les échelons pour les
échelles à deux montants échelles à un seul montant
c) Charges simulées pour les montants (dessin schématique)
Légende
F charge simulée pour les échelons
F charge simulée pour les montants
Figure 6 — Charges simulées exercées sur l’échelle
12 © ISO 2016 – Tous droits réservés
5.1.3 Chargement supplémentaire
5.1.3.1 Généralités
Le chargement supplémentaire, causé par exemple par le vent ou la neige, doit être pris en compte lors
des calculs de stabilité pour les dispositifs de protection contre les chutes (voir 5.1.3.2 et 5.1.3.3).
Le chargement sur les échelles, par exemple un choc avec un camion, n’est normalement pas pris en
compte.
5.1.3.2 Antichute
Les calculs doivent prendre en compte le chargement sur le support d’assurage et l’échelle lorsque le
dispositif de protection contre les chutes est activé par la chute d’une personne. En l’absence de données
réelles, une force verticale minimale de 6 kN doit être prise en compte.
5.1.3.3 Crinoline
Pour la conception de la crinoline, au moins la procédure d’essai décrite au 6.2.2 doit être appliquée.
5.1.3.4 Système d’ancrage
Les calculs doivent prendre en compte une charge minimale ≥ 3 kN pesant sur chaque montant pour les
échelles avec deux montants, et une charge ≥ 6 kN pesant sur le montant unique des échelles à un seul
montant.
Pour les calculs, il est supposé que la charge sera transmise aux parties fixes de l’environnement (par
exemple un mur ou l’enceinte de la machine) par quatre points d’ancrage.
a) Echelle avec deux montants b) Echelle avec un seul montant
Légende
1 échelon
2 montant
3 patte de fixation
4 point d’ancrage
5 partie fixe (par exemple mur)
Figure 7 — Disposition des points d’ancrage et des fixations
5.1.4 Conception
Les échelles doivent être conçues pour répondre aux mêmes exigences d’installation que celles de la
machine, en tenant compte si nécessaire de conditions telles que les atmosphères agressives ou les
vibrations.
Il convient que toute partie susceptible d’être en contact avec les utilisateurs soit conçue de manière à
ne pas attraper, blesser (par exemple, par des angles vifs et les arêtes vives, les soudures avec bavures)
ou gêner les personnes.
L’ouverture ou la fermeture des éléments mobiles (portillons) ne doit pas causer des risques
complémentaires, tels que cisaillement ou chute accidentelle.
Les fixations, articulations, points d’ancrage, supports, et scellements doivent conserver l’assemblage
suffisamment rigide et stable pour assurer la sécurité des utilisateurs dans les conditions normales
d’utilisation.
5.2 Échelle à deux montants
5.2.1 Résistance
Les éléments de l’échelle doivent être conformes aux exigences de vérification de stabilité par calcul du
6.1 ou par l’essai en 6.2.
5.2.2 Échelons
5.2.2.1 Résistance
Les échelons doivent être conformes aux exigences de vérification de stabilité par calcul du 6.1 ou par
l’essai en 6.2.
5.2.2.2 Espacement
À l’exception des exigences d’espacement entre les échelons dans l’aire de départ (voir 5.4.2 et Figure 8),
l’espacement entre deux échelons successifs, A, doit être constant et être compris entre 225 mm et 300 mm.
14 © ISO 2016 – Tous droits réservés
Dimensions en millimètres
•
Légende
A espacement
Figure 8 — Espacement et longueur des échelons
5.2.2.3 Longueur des échelons
La largeur de dégagement entre les deux montants doit être comprise entre 400 mm et 600 mm (voir
Figure 8). Cependant, une largeur de dégagement comprise entre 300 mm et 400 mm, est permise
au cas où l’environnement immédiat fait qu’il est impossible d’utiliser 400 mm. Avant de considérer
une largeur de dégagement plus petite, il y a lieu d’effectuer un contrôle préalable pour voir s’il est
possible de trouver un emplacement plus favorable pour l’échelle autorisant une largeur de dégagement
minimale de 400 mm.
En cas d’utilisation d’un antichute, la largeur de dégagement entre les montants et le support d’assurage
rigide pour antichute mobile doit être au minimum de 150 mm et l’épaisseur du support d’assurage
rigide ne doit pas être supérieure à 80 mm (voir Figure 9).
A A
Dimensions en millimètres
Figure 9 — Longueur des échelons d’une échelle à deux montants avec un support d’assurage
rigide pour antichute
5.2.2.4 Forme des échelons
La surface de circulation doit être plate et ≥ 20 mm [voir Figure 10 a) à c)]. Des échelons ronds ne
doivent donc pas être utilisés. Une surface de circulation inclinée est exceptionnellement permise si elle
est conforme à la Figure 10 d).
La périmètre total des échelons fermés, par exemple échelons à section carrée, rectangulaire,
polygonale, ou inclinée, doit être ≤ 140 mm.
Les échelons ouverts, tels que les échelons à profil en U ne pouvant pas être englobés, doivent être
conçus de manière à éviter les blessures à la main provenant d’arêtes vives.
Pour les échelles fixes sans dispositif de protection contre les chutes, avec une faible hauteur de
montée et un degré élevé de pollution provenant de l’environnement, des échelons larges antidérapants
comportant par exemple au minimum deux rangées de perforations peuvent être utilisés.
Des mesures spéciales de prévention peuvent être nécessaires lorsque le risque de glissement est
augmenté en raison des conditions environnementales (huile, glace, etc.). Lorsque l’accumulation, par
exemple de neige, de glace, ou de poussière est présente, des échelons avec bord incliné peuvent être
utilisés, conformément à la Figure 10 d).
La surface des échelons doit être antidérapante et ne doit provoquer aucune blessure des mains.
Jusqu’à ce qu’une Norme internationale relative à la résistance au glissement soit disponible, voir
ISO 14122-2:2016, Annexe A.
5.2.2.5 Position des échelons
Les échelons doivent être positionnés de manière à ce que leur surface de circulation perpendiculaire
soit à l’axe du montant (voir Figure 10).
16 © IS
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...