ISO 7176-16:2012 specifies requirements and test methods to assess the resistance to ignition by match flame equivalent of all postural support devices that are supplied to be part of a wheelchair or its seating system. ISO 7176-16:2012 only determines the resistance to ignition of the devices tested and not the ignitability of the complete wheelchair. ISO 7176-16:2012 allows for the separate testing of inferior/superior supports (e.g. arm supports), which are usually used in the horizontal plane, and anterior/posterior/lateral/medial supports (e.g. thoracic harnesses, calf panels), which are usually used in the vertical plane.
Fauteuils roulants — Partie 16: Résistance à l'inflammation des dispositifs de soutien postural
L'ISO 7176-16:2012 spécifie les exigences ainsi que les méthodes d'essai pour l'évaluation de la résistance à l'inflammation, par une flamme simulant une allumette, de tous les dispositifs de soutien postural qui sont fournis comme faisant partie d'un fauteuil roulant ou de son système de soutien. L'ISO 7176-16:2012 détermine uniquement la résistance à l'inflammation des dispositifs soumis à essai et non l' inflammabilité du fauteuil roulant complet. L'ISO 7176-16:2012 permet de conduire séparément un essai des supports inférieurs/supérieurs (par exemple, des accoudoirs) qui sont généralement utilisés dans le plan horizontal, et des supports antérieurs/postérieurs/latéraux/médiaux (par exemple, des harnais thoraciques, des panneaux de mollets) qui sont généralement utilisés dans le plan vertical.
General Information
Relations
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 7176-16
Second edition
2012-12-01
Wheelchairs —
Part 16:
Resistance to ignition of postural
support devices
Fauteuils roulants —
Partie 16: Résistance à l’inflammation des dispositifs de soutien postural
Reference number
ISO 7176-16:2012(E)
©
ISO 2012
---------------------- Page: 1 ----------------------
ISO 7176-16:2012(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2012
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any
means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the
address below or ISO’s member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2012 – All rights reserved
---------------------- Page: 2 ----------------------
ISO 7176-16:2012(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International
Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies
casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 7176-16 was prepared by Technical Committee ISO/TC 173, Assistive products for persons with
disability, Subcommittee SC 1, Wheelchairs.
This second edition cancels and replaces the first edition (ISO 7176-16:1997), which has been
technically revised.
ISO 7176 consists of the following parts, under the general title Wheelchairs:
— Part 1: Determination of static stability
— Part 2: Determination of dynamic stability of electric wheelchairs
— Part 3: Determination of effectiveness of brakes
— Part 4: Energy consumption of electric wheelchairs and scooters for determination of theoretical
distance range
— Part 5: Determination of dimensions, mass and manoeuvring space
— Part 6: Determination of maximum speed, acceleration and deceleration of electric wheelchairs
— Part 7: Measurement of seating and wheel dimensions
— Part 8: Requirements and test methods for static, impact and fatigue strengths
— Part 9: Climatic tests for electric wheelchairs
— Part 10: Determination of obstacle-climbing ability of electrically powered wheelchairs
— Part 11: Test dummies
— Part 13: Determination of coefficient of friction of test surfaces
— Part 14: Power and control systems for electrically powered wheelchairs and scooters — Requirements
and test methods
— Part 15: Requirements for information disclosure, documentation and labelling
— Part 16: Resistance to ignition of postural support devices
— Part 19: Wheeled mobility devices for use as seats in motor vehicles
© ISO 2012 – All rights reserved iii
---------------------- Page: 3 ----------------------
ISO 7176-16:2012(E)
— Part 21: Requirements and test methods for electromagnetic compatibility of electrically powered
wheelchairs and scooters, and battery chargers
— Part 22: Set-up procedures
— Part 23: Requirements and test methods for attendant-operated stair-climbing devices
— Part 24: Requirements and test methods for user-operated stair-climbing devices
— Part 25: Batteries and chargers for powered wheelchairs - Requirements and test methods
— Part 26: Vocabulary
— Part 28: Requirements and test methods for stair-climbing devices
A technical report (ISO/TR 13570-1) is also available giving a simplified explanation of these parts of ISO 7176.
iv © ISO 2012 – All rights reserved
---------------------- Page: 4 ----------------------
ISO 7176-16:2012(E)
Introduction
The ignition and subsequent burning of wheelchairs is very rare, but can occur as a result of:
— being close to a burning object such as a fire beside the wheelchair;
— overheating of any electrical or electronic device on the wheelchair;
— fire sources (such as cigarettes or matches) falling onto the wheelchair.
Wheelchair occupants are at particular risk of injury or death from these fires and resulting fumes
because they may not have the ability to move away from the wheelchair.
Wheelchairs can be considered to be comprised of the following components:
a) structural components such as the frame, wheels, etc., which are essential to the mechanical
integrity of the wheelchair;
b) postural support devices, such as sling seats, sling backs, arm supports, foot supports, etc., which
are attached to the wheelchair and/or its seating system and are primarily intended to give postural
support to the wheelchair occupant;
c) components to manage tissue integrity, such as seat or back support cushions, which are intended to
have primarily a clinical function to minimize the risks of skin damage (these may also be intended
to control posture);
d) power-related components such as motors, energy sources, controllers, etc., which are required for
the functioning of powered wheelchairs.
Each of the above components has a different severity of risk associated with their likelihood of igniting
and of their resulting harm to the wheelchair occupant. ISO standards have been published or are in
preparation to specify requirements and test methods for the above categories of components in order
to help manufacturers and purchasers of wheelchairs to design and procure wheelchairs and their
components which are appropriate for the risk of ignition balanced against the requirements of the
wheelchair occupant. The aim of these ISO standards is to provide appropriate alternatives to using
furniture-based standards, to reflect the uses and purposes of wheelchairs and their accessories.
The development of an ISO standard on the resistance to ignition of structural components [see list item
a) above] has not yet commenced. The most likely sources of ignition are proximity to a heat source such
as an electric radiator or domestic fire or a heat source such as a lighted match or cigarette falling onto
the structure.
The tissue integrity components [see c)] are the subject of a draft ISO standard (ISO 16840-10), and
permit a less stringent resistance to ignition based upon their priority for their clinical function which
can override the need for a high resistance to ignitability.
The power related components [see d)] are the subject of ISO 7176-14 which specifies requirements to
prevent overheating in electrical components that could lead to a fire.
This part of ISO 7176 is primarily concerned with the resistance to ignition of postural support devices
[see b)] of a wheelchair. These typically include arm supports, sling seats, sling backs, lower leg supports,
foot supports, lateral supports, head supports, etc. The most likely source of ignition is an open flame
source falling onto the component’s surface or into gaps between surfaces. Consequently, this part of
ISO 7176 is written around resistance to an ignition source equivalent to a lighted match in contact
with a test sample of an assembly of the upholstered part’s composite materials in both a vertical and
horizontal orientation. This part of ISO 7176 replaces ISO 7176-16:1997 since the latter only related to
upholstered parts of a wheelchair and was originally based on furniture test methods and requirements,
and therefore was not appropriate for clinically oriented components on a wheelchair.
The requirements of this part of ISO 7176 have been set at a basic minimum level and are less severe
than mandatory requirements in some countries. Good practice is also to use materials which minimize
© ISO 2012 – All rights reserved v
---------------------- Page: 5 ----------------------
ISO 7176-16:2012(E)
the risk of release of toxic substances as a result of ignition. Materials chosen shall also comply with
biocompatibility requirements.
The day-to-day usage of a wheelchair can affect its materials’ resistance to ignition through cyclic
loading, movement of materials, washing, cleaning, etc. Manufacturers will often take these effects into
account as part of their risk assessment when selecting materials for their products, to minimize the
effects of this normal use. However, although this part of ISO 7176 can be used on parts that have been
used, etc., the test samples specify new or unused parts.
Different environments commonly encountered by some wheelchair occupants can also affect the
flammability of materials. For example, home oxygen systems, delivery systems for drugs carried in an
inflammable medium, etc., can turn an inert material into a flammable one. Dust and other materials
accumulated within the chair have also been found to be a source of readily ignitable material.
Wheelchair manufacturers and occupants should be aware of these risks, and design and use wheelchairs
accordingly, as covered by ISO 14971.
This part of ISO 7176 describes testing an assembly of the composite of materials as used in the
wheelchair component, because the resistance to ignition of these materials individually may be quite
different from those when assembled as a composite. Hence the results of testing to this part of ISO 7176
do not give any indication of the resistance to ignition of any of the separate individual materials of the
postural support device.
vi © ISO 2012 – All rights reserved
---------------------- Page: 6 ----------------------
INTERNATIONAL STANDARD ISO 7176-16:2012(E)
Wheelchairs —
Part 16:
Resistance to ignition of postural support devices
1 Scope
This part of ISO 7176 specifies requirements and test methods to assess the resistance to ignition by
match flame equivalent of all postural support devices that are supplied to be part of a wheelchair or its
seating system.
This part of ISO 7176 only determines the resistance to ignition of the devices tested and not the
ignitability of the complete wheelchair.
This part of ISO 7176 does not apply to the resistance to ignition of other parts of a wheelchair, e.g.
wheels, framework.
This part of ISO 7176 does not take into consideration changes in resistance to ignition as a result of
washing or use.
This part of ISO 7176 allows for the separate testing of inferior/superior supports (e.g. arm supports),
which are usually used in the horizontal plane, and anterior/posterior/lateral/medial supports (e.g.
thoracic harnesses, calf panels), which are usually used in the vertical plane.
Until such time as a flammability standard is available for the testing of other components or accessories
of the wheelchair, it is advisable that any structural components considered to be at risk are tested at
least to the ignitability levels of this part of ISO 7176.
NOTE 1 The requirements of this part of ISO 7176 have been set at a basic minimum level and are less severe
than mandatory requirements in some countries.
Where practical, it is advisable that manufacturers use materials with superior resistance to ignition.
NOTE 2 Requirements for the control of risks from sources of fire created by electrical and electronic
components are included in ISO 7176-14.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 8191-2:1988, Furniture — Assessment of ignitability of upholstered furniture — Part 2: Ignition source:
match flame equivalent
ISO 7176-15, Wheelchairs — Part 15: Requirements for information disclosure, documentation and labelling
ISO 7176-26, Wheelchairs — Part 26: Vocabulary
ISO 554, Standard atmospheres for conditioning and/or testing — Specifications
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 7176-26 and the following apply.
© ISO 2012 – All rights reserved 1
---------------------- Page: 7 ----------------------
ISO 7176-16:2012(E)
3.1
progressive smouldering
exothermic oxidation, not accompanied by flaming, that is self-propagating, i.e. independent of the
ignition source. It may or may not be accompanied by incandescence
[ISO 8191-2:1988, definition 3.1]
3.2
flaming
undergoing combustion in the gaseous phase with the emission of light
[ISO 8191-2:1988, definition 3.2]
4 Principle
Test materials as used in any postural support devices are assembled in either horizontal or vertical
samples and subjected to an ignition source which is equivalent to a match flame. The resulting effects
on the test materials are observed and measured.
5 Health and safety of test personnel
5.1 General
WARNING — The following test methods call for the use of procedures that may be injurious to
health if adequate precautions are not taken
...
NORME ISO
INTERNATIONALE 7176-16
Deuxième édition
2012-12-01
Fauteuils roulants —
Partie 16:
Résistance à l’inflammation des
dispositifs de soutien postural
Wheelchairs —
Part 16: Resistance to ignition of postural support devices
Numéro de référence
ISO 7176-16:2012(F)
©
ISO 2012
---------------------- Page: 1 ----------------------
ISO 7176-16:2012(F)
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2012
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Version française parue en 2013
Publié en Suisse
ii © ISO 2012 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO 7176-16:2012(F)
Sommaire Page
Avant-propos .iv
Introduction .vi
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 2
4 Principe . 2
5 Santé et sécurité du personnel d’essai . 2
5.1 Généralités . 2
5.2 Enceinte. 2
5.3 Extincteurs . 2
6 Appareillage . 3
6.1 Banc d’essai . 3
6.2 Enceinte d’essai . 3
6.3 Minuterie . 3
6.4 Source d’allumage . 3
6.5 Réglage du débit de gaz . 3
6.6 Environnement de conditionnement . 4
6.7 Environnement d’essai . . 4
6.8 Échantillon d’essai . 4
7 Mode opératoire d’essai. 4
7.1 Préparation . 4
7.2 Essai horizontal . 5
7.3 Essai vertical . 7
7.4 Autres échantillons . 8
8 Exigences . 8
9 Rapport d’essai . 9
10 Divulgation des résultats . 9
Bibliographie .10
© ISO 2012 – Tous droits réservés iii
---------------------- Page: 3 ----------------------
ISO 7176-16:2012(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (CEI) en ce qui concerne
la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives
ISO/CEI, Partie 2.
La tâche principale des comités techniques est d’élaborer les Normes internationales. Les projets de
Normes internationales adoptés par les comités techniques sont soumis aux comités membres pour vote.
Leur publication comme Normes internationales requiert l’approbation de 75 % au moins des comités
membres votants.
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable de
ne pas avoir identifié de tels droits de propriété et averti de leur existence.
L’ISO 7176-16 a été élaborée par le comité technique ISO/TC 173, Assistances et aides techniques pour les
personnes invalides ou handicapées, sous-comité SC 1, Fauteuils roulants.
Cette deuxième édition annule et remplace la première édition (ISO 7176-16:1997), qui a fait l’objet d’une
révision technique.
L’ISO 7176 comprend les parties suivantes, présentées sous le titre général Fauteuils roulants:
— Partie 1: Détermination de la stabilité statique
— Partie 2: Détermination de la stabilité dynamique des fauteuils roulants électriques
— Partie 3: Détermination de l’efficacité des freins
— Partie 4: Consommation d’énergie des fauteuils roulants et des scooters électriques pour la détermination
de la distance théorique
— Partie 5: Détermination des dimensions, de la masse et de l’espace de manœuvre
— Partie 6: Détermination de la vitesse, de l’accélération et du ralentissement maximaux des fauteuils
roulants électriques
— Partie 7: Mesurage des dimensions d’assise et des roues
— Partie 8: Exigences et méthodes d’essai pour la résistance statique, la résistance aux chocs et la
résistance à la fatigue
— Partie 9: Essais climatiques pour fauteuils roulants électriques
— Partie 10: Détermination de l’aptitude des fauteuils roulants électriques à gravir les obstacles
— Partie 11: Mannequins d’essai
— Partie 13: Détermination du coefficient de frottement des surfaces d’essai
— Partie 14: Systèmes d’alimentation et de commande des fauteuils roulants et scooters électriques —
Exigences et méthodes d’essai
— Partie 15: Exigences relatives à la diffusion des informations, à la documentation et à l’étiquetage
iv © ISO 2012 – Tous droits réservés
---------------------- Page: 4 ----------------------
ISO 7176-16:2012(F)
— Partie 16: Résistance à l’inflammation des dispositifs de soutien postural
— Partie 19: Dispositifs de mobilité montés sur roues et destinés à être utilisés comme sièges dans des
véhicules à moteur
— Partie 21: Exigences et méthodes d’essai pour la compatibilité des fauteuils roulants électriques et
scooters motorisés
— Partie 22: Modes opératoires de réglage
— Partie 23: Exigences et méthodes d’essai pour les monte-escalier manipulés par une tierce personne
— Partie 24: Exigences et méthodes d’essai pour les monte-escalier manipulés par l’utilisateur
— Partie 25: Batteries et chargeurs pour fauteuils roulants motorisés — Exigences et méthodes d’essai
— Partie 26: Vocabulaire
— Partie 28: Exigences et méthodes d’essai pour les dispositifs monte-escalier
Un Rapport technique (ISO/TR 13570-1) donnant une explication simplifiée de ces parties est
également disponible.
© ISO 2012 – Tous droits réservés v
---------------------- Page: 5 ----------------------
ISO 7176-16:2012(F)
Introduction
L’inflammation et la combustion consécutive des fauteuils roulants sont très rares, mais peuvent se
produire pour les causes suivantes:
— proximité d’un objet en combustion tel qu’un feu à côté du fauteuil roulant;
— surchauffe d’un dispositif électrique ou électronique sur le fauteuil roulant;
— la chute de sources d’incendie (telles que des cigarettes ou des allumettes) sur le fauteuil roulant.
Les occupants de fauteuils roulants présentent un risque particulier de blessure ou de décès dus à ces
incendies et aux fumées résultantes parce qu’ils n’ont pas la capacité de s’éloigner du fauteuil roulant.
Il peut être considéré que les fauteuils roulants sont constitués des composants suivants:
a) les composants structuraux tels que le châssis, les roues, etc., qui sont essentiels pour l’intégrité
mécanique du fauteuil roulant;
b) les dispositifs de soutien postural, tels que les toiles de siège, les toiles de dossier, les accoudoirs,
les repose-pieds, etc., qui sont fixés au fauteuil roulant et/ou son système de soutien et sont
principalement destinés à apporter un soutien postural à l’occupant du fauteuil roulant;
c) les composants permettant de contrôler l’intégrité des tissus tels que les coussins de siège ou de
dossier qui sont principalement destinés à avoir une fonction clinique pour réduire au minimum les
risques de dommages de la peau (ceux-ci peuvent également être destinés à contrôler la posture);
d) les composants associés à la motorisation, tels que les moteurs, les sources d’énergie, les dispositifs
de commande, etc., qui sont nécessaires pour le fonctionnement des fauteuils roulants motorisés.
Chacun des composants ci-dessus présente un niveau de risque différent associé à sa probabilité
d’inflammation et des conséquences néfastes consécutives pour l’occupant du fauteuil roulant. Des
normes ISO ont été publiées ou sont en cours de rédaction pour spécifier les exigences et les méthodes
d’essai pour les catégories de composants ci-dessus afin d’aider les fabricants et les acheteurs de fauteuils
roulants à concevoir et fournir des fauteuils roulants et leurs composants qui soient appropriés pour le
risque d’inflammation conformément aux exigences de l’occupant du fauteuil roulant. L’objectif de ces
normes ISO est de proposer des alternatives appropriées à l’utilisation de normes basées sur le mobilier,
afin de refléter les utilisations et les applications des fauteuils roulants et de leurs accessoires.
Le développement d’une norme ISO sur la résistance à l’inflammation de composants structuraux
[voir liste a) ci-dessus] n’a pas encore commencé. Les sources d’inflammation les plus probables sont la
proximité d’une source de chaleur telle qu’un radiateur électrique ou un feu domestique ou une source
de chaleur telle qu’une allumette ou une cigarette allumée tombant sur la structure.
Les composants pour préserver l’intégrité des tissus [voir c)] sont l’objet d’un projet de norme ISO
(ISO 16840-10), et permettent d’obtenir une résistance moins stricte à l’allumage sur la base de leur
priorité pour leur fonction clinique qui peut supplanter la nécessité d’une résistance à l’allumage élevée.
Les composants associés à la motorisation [voir d)] sont le sujet de l’ISO 7176-14, qui spécifie des exigences
pour prévenir une surchauffe des composants électriques qui pourraient conduire à un incendie.
La présente partie de l’ISO 7176 concerne principalement la résistance à l’inflammation des dispositifs
de soutien postural [voir b)] d’un fauteuil roulant. Ceux-ci comprennent typiquement les accoudoirs, les
toiles de siège, les repose-jambes, les repose-pieds, les supports latéraux, les repose-tête, etc. La source
d’inflammation la plus probable est une flamme nue tombant sur la surface du composant ou dans des
espacements entre des surfaces. Par conséquent, la présente partie de l’ISO 7176 a été rédigée en se
focalisant sur la résistance à la flamme simulant une allumette allumée en contact avec un échantillon
d’essai d’un ensemble de matériaux composites des parties rembourrées dans une orientation verticale
et horizontale. La présente partie de l’ISO 7176 remplace l’ISO 7176-16:1997 puisque cette dernière
concernait uniquement les parties rembourrées d’un fauteuil roulant et était initialement basée sur des
vi © ISO 2012 – Tous droits réservés
---------------------- Page: 6 ----------------------
ISO 7176-16:2012(F)
méthodes d’essai et des exigences concernant des meubles, et n’était par conséquent pas adaptée aux
composants cliniques d’un fauteuil roulant.
Les exigences de la présente partie de l’ISO 7176 ont été définies à un niveau minimal de base et sont
moins strictes que les exigences réglementaires dans certains pays. La bonne pratique consiste en
outre à utiliser des matériaux qui réduisent au minimum le risque de libération de substances toxiques
consécutive à une inflammation. Les matériaux choisis doivent également être conformes aux exigences
de biocompatibilité.
L’utilisation quotidienne d’un fauteuil roulant peut affecter la résistance à l’inflammation de ses
matériaux par l’intermédiaire de cycles de chargement, mouvement des matériaux, lavage, nettoyage,
etc. Les fabricants prennent souvent en compte ces effets dans le cadre de leur évaluation des risques
lors de la sélection de matériaux pour leurs produits afin de réduire au minimum les effets de cette
utilisation normale. Cependant, bien que la présente partie de l’ISO 7176 puisse être utilisée sur des
éléments qui ont été utilisés, etc., les échantillons d’essai spécifiés sont des articles neufs ou inutilisés.
Différents environnements couramment rencontrés par des occupants de fauteuil roulant peuvent
également affecter l’inflammabilité des matériaux. Par exemple, des systèmes d’administration d’oxygène
à domicile, des systèmes d’administration de médicaments véhiculés dans un milieu inflammable,
etc., peuvent rendre inflammable un matériau inerte. Il a également été observé que les poussières et
d’autres matériaux accumulés dans le fauteuil constituent une source de matériaux aisément allumables.
Il convient que les fabricants et les occupants de fauteuils roulants soient conscients de ces risques, et
conçoivent et utilisent les fauteuils roulants en conséquence, comme spécifié par l’ISO 14971.
La présente partie de l’ISO 7176 décrit des essais effectués sur ensemble composite des matériaux utilisés
dans le fauteuil roulant, parce que la résistance à l’inflammation de ces matériaux pris individuellement
peut être très différente de celle observée lorsqu’ils sont assemblés en un produit composite. Par
conséquent, les résultats d’essais de la présente partie de l’ISO 7176 ne donnent aucune indication sur la
résistance à l’inflammation de l’un quelconque des matériaux individuels séparés du soutien postural.
© ISO 2012 – Tous droits réservés vii
---------------------- Page: 7 ----------------------
NORME INTERNATIONALE ISO 7176-16:2012(F)
Fauteuils roulants —
Partie 16:
Résistance à l’inflammation des dispositifs de soutien
postural
1 Domaine d’application
La présente partie de l’ISO 7176 spécifie les exigences ainsi que les méthodes d’essai pour l’évaluation de
la résistance à l’inflammation, par une flamme simulant une allumette, de tous les dispositifs de soutien
postural qui sont fournis comme faisant partie d’un fauteuil roulant ou de son système de soutien.
Elle détermine uniquement la résistance à l’inflammation des dispositifs soumis à essai et non
l’inflammabilité du fauteuil roulant complet.
La présente partie de l’ISO 7176 ne s’applique pas à la résistance à l’inflammation d’autres parties d’un
fauteuil roulant, par exemple, les roues, le châssis.
Elle ne prend pas en considération les changements de résistance à l’inflammati
...