Primary batteries - Part 3: Watch batteries

IEC 60086-3:2011(E) specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used. The major technical changes with respect to the previous edition are the drawings, a review of the table of electrochemical systems and a harmonization of the marking clause with the other standards of the IEC 60086 series. Moreover, the table of the leakage levels was extended by adding drawings with better visualization. This publication is published as a double logo standard.

Primärbatterien - Teil 3: Uhrenbatterien

Piles électriques - Partie 3 : Piles pour montres

L'IEC 60086-3:2016 spécifie les dimensions, la désignation, les méthodes d'essai et les exigences applicables aux piles électriques pour montres. Dans certains cas, un choix de méthodes d'essai est proposé. Lorsque le fabricant présente les caractéristiques électriques et/ou les performances de la pile, il précise la méthode d'essai qui a été utilisée. Cette quatrième édition annule et remplace la troisième édition parue en 2011. Cette édition constitue une révision technique. Cette édition inclut les modifications techniques majeures suivantes par rapport à l'édition précédente: - Harmonisation des tailles des éléments et des essais de capacité avec l'IEC 60086-2; - Clarification des Articles 6: Echantillonnage et assurance de la qualité, 7: Méthodes d'essai, et 8: Examen visuel et conditions d'acceptation; - Harmonisation des conditions de température et d'humidité avec celles de l'IEC 60086-1. La présente norme est une norme double logo. Mots clés: piles électriques pour montres

Primarne baterije - 3. del: Baterije za zapestne ure (IEC 60086-3:2016)

Standard IEC 60086-3:2011(E) opredeljuje mere, označevanje, preskusne metode in zahteve za primarne baterije za zapestne ure. V številnih primerih je podan meni s preskusnimi metodami. Pri predstavitvi električnih lastnosti in/ali podatkov o delovanju proizvajalec navede, katera preskusna metoda je bila uporabljena. Glavne tehnične spremembe v primerjavi s prejšnjo izdajo so risbe, pregled razpredelnice z elektrokemičnimi sistemi in uskladitev točke o označevanju z drugimi standardi iz skupine IEC 60086. Poleg tega so bile razpredelnici z ravnmi uhajanja dodane nazornejše risbe. Ta publikacija je objavljena kot standard z dvojnim logotipom.

General Information

Status
Withdrawn
Publication Date
29-Sep-2016
Withdrawal Date
28-Jun-2019
Technical Committee
Drafting Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Jun-2024
Completion Date
01-Jun-2024

Relations

Buy Standard

Standard
EN 60086-3:2016
English language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2016
1DGRPHãþD
SIST EN 60086-3:2011
Primarne baterije - 3. del: Baterije za zapestne ure (IEC 60086-3:2016)
Primary batteries - Part 3: Watch batteries (IEC 60086-3:2016)
Piles électriques - Partie 3 : piles pour montres (IEC 60086-3:2016)
Ta slovenski standard je istoveten z: EN 60086-3:2016
ICS:
29.220.10 3ULPDUQLþOHQLLQEDWHULMH Primary cells and batteries
39.040.10 Zapestne, žepne ure Watches
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 60086-3
NORME EUROPÉENNE
EUROPÄISCHE NORM
September 2016
ICS 29.220.10; 39.040.10 Supersedes EN 60086-3:2011
English Version
Primary batteries - Part 3: Watch batteries
(IEC 60086-3:2016)
Piles électriques - Partie 3 : Piles pour montres Primärbatterien - Teil 3: Uhrenbatterien
(IEC 60086-3:2016) (IEC 60086-3:2016)
This European Standard was approved by CENELEC on 2016-06-29. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 60086-3:2016 E
European foreword
The text of document 35/1359/FDIS, future edition 4 of IEC 60086-3, prepared by IEC/TC 35 "Primary
cells and batteries" and by ISO/TC 114 "Horology" was submitted to the IEC-CENELEC parallel vote
and approved by CENELEC as EN 60086-3:2016.
The following dates are fixed:
(dop) 2017-03-29
• latest date by which the document has to be implemented at
national level by publication of an identical national
standard or by endorsement
(dow) 2019-06-29
• latest date by which the national standards conflicting with
the document have to be withdrawn

This document supersedes EN 60086-3:2011.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 60086-3:2016 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated :
IEC 60068-2-78:2001 NOTE Harmonized as EN 60068-2-78:2001 (not modified).
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is
available here: www.cenelec.eu.

Publication Year Title EN/HD Year
IEC 60086-1 2015 Primary batteries - EN 60086-1 2015
Part 1: General
IEC 60086-2 2015 Primary batteries - EN 60086-2 2016
Part 2: Physical and electrical
specifications
IEC 60086-4 2014 Primary batteries - EN 60086-4 2015
Part 4: Safety of lithium batteries
1)
IEC 60086-5 2016 Primary batteries - EN 60086-5
Part 5: Safety of batteries with aqueous
electrolyte
1) To be published.
IEC 60086-3
Edition 4.0 2016-05
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Primary batteries –
Part 3: Watch batteries
Piles électriques –
Partie 3: Piles pour montres
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 29.220.10; 39.040.10 ISBN 978-2-8322-3402-0

– 2 – IEC 60086-3:2016 © IEC 2016
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references. 7
3 Terms and definitions . 7
4 Physical requirements. 8
4.1 Battery dimensions, symbols and size codes . 8
4.2 Terminals . 10
4.3 Projection of the negative terminal (h ) . 10
4.4 Shape of negative terminal . 10
4.5 Mechanical resistance to pressure . 11
4.6 Deformation . 11
4.7 Leakage . 11
4.8 Marking . 12
4.8.1 General . 12
4.8.2 Disposal . 12
5 Electrical requirements . 12
5.1 Electrochemical system, nominal voltage, end-point voltage and open-circuit
voltage . 12
5.2 Closed circuit voltage U (CCV), internal resistance and impedance . 13
cc
5.3 Capacity . 13
5.4 Capacity retention . 13
6 Sampling and quality assurance . 13
7 Test methods . 13
7.1 Shape and dimensions . 13
7.1.1 Shape requirement . 13
7.2 Electrical characteristics . 14
7.2.1 Environmental conditions . 14
7.2.2 Equivalent circuit – effective internal resistance – DC method . 14
7.2.3 Equipment . 15
7.2.4 Measurement of open-circuit voltage U (OCV) and closed circuit
oc
voltage U (CCV) . 15
cc
7.2.5 Calculation of the internal resistance R . 16
i
7.2.6 Measurement of the capacity . 16
7.2.7 Calculation of the internal resistance R during discharge in case of
i
method A (optional) . 18
7.3 Test methods for determining the resistance to leakage . 20
7.3.1 Preconditioning and initial visual examination . 20
7.3.2 High temperature and humidity test . 20
7.3.3 Test by temperature cycles . 20
8 Visual examination and acceptance conditions . 21
8.1 Preconditioning . 21
8.2 Magnification . 21
8.3 Lighting . 21
8.4 Leakage levels and classification . 21
8.5 Acceptance conditions. 23

IEC 60086-3:2016 © IEC 2016 – 3 –
Annex A (normative) Designation . 24
Bibliography . 25

Figure 1 – Dimensional drawing . 8
Figure 2 – Shape of negative terminal . 11
Figure 3 – Shape requirement . 14
Figure 4 – Schematic voltage transient . 14
Figure 5 – Curve: U = f(t) . 15
Figure 6 – Circuitry principle . 16
Figure 7 – Circuitry principle for method A . 17
Figure 8 – Circuitry principle for method B . 18
Figure 9 – Test by temperature cycles . 20

Table 1 – Dimensions and size codes . 9
Table 2 – Dimensions and size codes . 10
Table 3 – Minimum values of l . 11
Table 4 – Applied force F by battery dimensions . 11
Table 5 – Standardised electrochemical systems . 12
Table 6 – Test method for U (CCV) measurement . 16
cc
Table 7 – Test method A for U (CCV) measurement . 17
cc
Table 8 – Discharge resistance (values) . 19
Table 9 – Storage conditions for the recommended test . 20
Table 10 – Storage conditions for optional test . 20
Table 11 – Leakage levels and classification (1 of 2) . 22

– 4 – IEC 60086-3:2016 © IEC 2016
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
PRIMARY BATTERIES –
Part 3: Watch batteries
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International S
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.