39 - PRECISION MECHANICS. JEWELLERY
ICS 39 Details
PRECISION MECHANICS. JEWELLERY
FEINMECHANIK. SCHMUCKWAREN
MECANIQUE DE PRECISION. BIJOUTERIE
FINOMEHANIKA. NAKIT
General Information
e-Library Subscription
Create subscription and get permanent access to documents within 39 - PRECISION MECHANICS. JEWELLERY
Currently subscription includes documents marked with .We are working on making all documents available within the subscription.
This document specifies an analytical procedure for the determination of gold, silver, platinum and palladium with a nominal content of and above 999 ‰ (parts per thousand, by mass), using an optical emission spectrometer with excitation by spark discharge (SPARK-OES).
- Standard7 pagesEnglish languagesale 15% off
- Standard8 pagesFrench languagesale 15% off
This document specifies a volumetric method for the determination of silver on a material considered homogeneous. The silver content of the sample lies preferably between (100 and 999,0) parts per thousand (‰) by mass. Fineness above 999,0 ‰ can be determined using a spectroscopy method by difference (e.g. ISO 15096).
This method is intended to be used as the reference method for the determination of fineness in alloys covered by ISO 9202.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a volumetric method for the determination of silver on a material considered homogeneous. The silver content of the sample lies preferably between (100 and 999,0) parts per thousand (‰) by mass. Fineness above 999,0 ‰ can be determined using a spectroscopy method by difference (e.g. ISO 15096).
This method is intended to be used as the reference method for the determination of fineness in alloys covered by ISO 9202.
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the terminology, classification and test methods that are used for the inspection of batches of unmounted polished colourless diamonds with single mass smaller than or equal to 0,25 ct (carat). While the inspection of a batch is made one diamond at a time, the use of this document is not to be claimed for one single diamond only nor for fancy coloured diamonds, nor for synthetic diamonds, nor for treated diamonds, neither for assembled stones.
- Standard21 pagesEnglish languagesale 15% off
This document specifies a volumetric method for the determination of silver on a material considered homogeneous. The silver content of the sample lies preferably between (100 and 999,0) parts per thousand (‰) by mass. Fineness above 999,0 ‰ can be determined using a spectroscopy method by difference (e.g. ISO 15096). This method is intended to be used as the reference method for the determination of fineness in alloys covered by ISO 9202.
- Standard5 pagesEnglish languagesale 15% off
- Standard5 pagesFrench languagesale 15% off
This document specifies a volumetric method for the determination of silver on a material considered homogeneous. The silver content of the sample lies preferably between (100 and 999,0) parts per thousand (‰) by mass. Fineness above 999,0 ‰ can be determined using a spectroscopy method by difference (e.g. ISO 15096). This method is intended to be used as the reference method for the determination of fineness in alloys covered by ISO 9202.
- Standard5 pagesEnglish languagesale 15% off
- Standard10 pagesEnglish languagesale 15% off
- Standard12 pagesFrench languagesale 15% off
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies an analytical procedure for the determination of very high purity gold with a nominal content of and above 999,99 ‰ (parts per thousand, by mass), using an inductively coupled plasma mass spectrometer (ICP-MS).
- Standard9 pagesEnglish languagesale 15% off
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard2 pagesEnglish and French languagesale 15% off
- Standard2 pagesEnglish and French languagesale 15% off
Considering amongst other topics the following: comments from Systematic review, adopt changes regarding reference material and quality control material, concentration and purity of lactic acid and the flow chart regarding Annex C, watches Round robins for reference material and quality control materials are needed.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a gravimetric method for the determination of palladium in palladium alloys. The palladium content of the sample lies preferably between 50 and 999 parts per thousand (‰). Fineness above 999 ‰ can be determined using a spectroscopy method by difference (e.g. ISO 15093).
This method is also intended to be used as one of the recommended methods for the determination of fineness in jewellery alloys covered by ISO 9202.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a gravimetric method for the determination of platinum in platinum alloys. The platinum content of sample lies preferably between 50 and 999 parts per thousands (‰) by weight. Fineness above 999 ‰ can be determined using a spectroscopy method by difference (e.g. ISO 15093).
This method is also intended to be used as one of the recommended methods for the determination of fineness in jewellery alloys covered by ISO 9202.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a gravimetric method for the determination of platinum on a material considered homogeneous. The platinum content of the sample lies preferably between 50 and 999 parts per thousand (‰) by mass. Fineness above 999 ‰ can be determined using a spectroscopy method by difference (e.g. ISO 15093).
This method is also intended to be used as one of the recommended methods for the determination of fineness in jewellery alloys covered by ISO 9202.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a gravimetric method for the determination of palladium on a material considered homogeneous. The palladium content of the sample lies preferably between 50 and 999 parts per thousand (‰) by mass. Fineness above 999 ‰ can be determined using a spectroscopy method by difference (e.g. ISO 15093).
This method is also intended to be used as one of the recommended methods for the determination of fineness in jewellery alloys covered by ISO 9202.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a gravimetric method for the determination of platinum on a material considered homogeneous. The platinum content of the sample lies preferably between 50 and 999 parts per thousand (‰) by mass. Fineness above 999 ‰ can be determined using a spectroscopy method by difference (e.g. ISO 15093). This method is also intended to be used as one of the recommended methods for the determination of fineness in jewellery alloys covered by ISO 9202.
- Standard7 pagesEnglish languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
This document specifies a method for simulating the release of nickel from all post assemblies which are inserted into pierced ears and other pierced parts of the human body and articles intended to come into direct and prolonged contact with the skin in order to determine whether such articles are in compliance with No. 27 in Annex XVII of Regulation (EC) No 1907/2006 of the European Parliament and of the Council (REACH).
Spectacle frames and sunglasses are excluded from the scope of this document.
NOTE Spectacle frames and sunglasses are subject to the requirements of EN 16128.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a gravimetric method for the determination of palladium on a material considered homogeneous. The palladium content of the sample lies preferably between 50 and 999 parts per thousand (‰) by mass. Fineness above 999 ‰ can be determined using a spectroscopy method by difference (e.g. ISO 15093). This method is also intended to be used as one of the recommended methods for the determination of fineness in jewellery alloys covered by ISO 9202.
- Standard6 pagesEnglish languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
This document provides a sceening test based upon the use of dimethylglyoxime to detect nickel release from articles that are inserted into pierced parts of the human body and those that are intended to come into direct and prolonged contact with the skin.
The screening test is suitable for manufacturers and importers as a qualitative method for inspecting articles for nickel release.
NOTE The reference method for the measurement of nickel release in EN 1811, or for spectacle frames and sunglasses, EN 16128.
- Technical report12 pagesEnglish languagesale 10% offe-Library read for1 day
This document provides a screening test based upon the use of dimethylglyoxime for detecting the presence of nickel in articles that are inserted into pierced parts of the human body and those that are intended to come into direct and prolonged contact with the skin.
This screening test is suitable for manufacturers and importers as a qualitative method for detecting the presence of nickel in articles.
NOTE The reference method for the measurement of nickel release is EN 1811, or for spectacle frames and sunglasses, EN 16128.
- Technical report12 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a method of sampling precious metals and precious metal alloys for the determination of their precious metal content and for the assessment of their homogeneity. The document is applicable to raw materials, semi-finished products and finished products and is intended to be used only for the sampling of entirely metallic materials. NOTE 1 Standards for determination of precious metals contents for different metals are listed in the Bibliography. NOTE 2 For assaying techniques different from the listed ones other sampling procedures can be required. NOTE 3 For the purpose of production control or lot inspections the International Standards for the sampling indicated in the Bibliography or corresponding guidelines can be applied in addition.
- Standard13 pagesEnglish languagesale 15% off
- Standard13 pagesEnglish languagesale 15% off
- Standard14 pagesFrench languagesale 15% off
- Standard14 pagesFrench languagesale 15% off
This document specifies a cupellation method (fire assay) for the determination of gold on a material considered homogeneous. The gold content of the sample lies preferably between 100 and 999,5 parts per thousand (‰) by weight. Fineness above 999,5 ‰ can be determined using a spectroscopy method by difference (e.g. ISO 15093).
The procedure is applicable to most types of gold samples. Some modifications are indicated for specific cases (presence of large amount of base metals, platinum or palladium, silver). It is not compatible with the presence above trace levels of iridium, rhodium and ruthenium (more than 0,25 ‰ for the sum of all three elements).
This method is also intended to be used as the recommended method for the determination of fineness in jewellery alloys covered by ISO 9202.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used.
- Draft16 pagesEnglish languagesale 15% off
This part of IEC 60086 specifies dimensions, designation, methods of tests and requirements
for primary batteries for watches. In several cases, a menu of test methods is given. When
presenting battery electrical characteristics and/or performance data, the manufacturer
specifies which test method was used.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
This document describes a non-destructive method to verify (confirm) the precious metal fineness of finished and semifinished jewellery item(s) considered homogeneous by ED-XRF (energy dispersive X-ray fluorescence), including alloys according to ISO 9202. This document is not suitable for any coated items. WD-XRF (wavelength dispersive X-ray fluorescence) equipment cannot be used.
- Standard7 pagesEnglish languagesale 15% off
- Standard7 pagesEnglish languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
IEC 60086-3:2021 is available as IEC 60086-3:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60086-3-5:2021 specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60730-2-7:2015(E) applies to timers and time switches for household and similar use that may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof, including heating, air conditioning and similar applications. This standard is also applicable to individual timers utilized as part of a control system or timers which are mechanically integral with multifunctional controls having non-electrical outputs. This standard does not apply to time-delay switches (TDS) within the scope of IEC 60669-2-3. This standard applies to the inherent safety, to the operating characteristics where such are associated with equipment protection and to the testing of timers used in appliances and other apparatus, electrical and non-electrical, for household and similar purposes, but also extended to industrial purposes when no dedicated product standards exist, such as that for central heating, air conditioning, process heating, etc. Timers for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. This third edition cancels and replaces the second edition published in 2008. This third edition constitutes a technical revision. This new edition revises the compliance criteria of type 1.S and 2.S action, revises the requirements for filament lamp loads, adds requirements for abnormal operation in Annex H, removes some special requirements for single countries as well as updates the standard to IEC 60730-1:2010, fourth edition.
Key words: Timers, Time Switches
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a cupellation method (fire assay) for the determination of gold on a material
considered homogeneous. The gold content of the sample lies preferably between 100 and 999,5 parts
per thousand (‰) by weight. Fineness above 999,5 ‰ can be determined using a spectroscopy method
by difference (e.g. ISO 15093).
The procedure is applicable to most types of gold samples. Some modifications are indicated for specific
cases (presence of large amount of base metals, platinum or palladium, silver). It is not compatible with
the presence above trace levels of iridium, rhodium and ruthenium (more than 0,25 ‰ for the sum of
all three elements).
This method is also intended to be used as the recommended method for the determination of fineness
in jewellery alloys covered by ISO 9202.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
IEC 60086-3:2021 is available as IEC 60086-3:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60086-3-5:2021 specifies dimensions, designation, methods of tests and requirements for primary batteries for watches. In several cases, a menu of test methods is given. When presenting battery electrical characteristics and/or performance data, the manufacturer specifies which test method was used.
The contents of the corrigendum of June 2023 have been included in this copy.
- Standard24 pagesEnglish languagesale 15% off
- Standard52 pagesEnglish languagesale 15% off
- Standard49 pagesEnglish and French languagesale 15% off
This document specifies a method for the simulation of accelerated wear and corrosion, to be used prior to the detection of nickel release from coated articles that come into direct and prolonged contact with the skin. According to the Commission Regulation (EC) No 1907/2006 (REACH), articles with an outer coating containing nickel and those which are inserted into pierced ears and other parts of the human body are excluded from the scope of this document.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard3 pagesEnglish languagesale 15% off
- Standard3 pagesEnglish languagesale 15% off
This document specifies a cupellation method (fire assay) for the determination of gold on a material considered homogeneous. The gold content of the sample lies preferably between 100 and 999,5 parts per thousand (‰) by weight. Fineness above 999,5 ‰ can be determined using a spectroscopy method by difference (e.g. ISO 15093). The procedure is applicable to most types of gold samples. Some modifications are indicated for specific cases (presence of large amount of base metals, platinum or palladium, silver). It is not compatible with the presence above trace levels of iridium, rhodium and ruthenium (more than 0,25 ‰ for the sum of all three elements). This method is also intended to be used as the recommended method for the determination of fineness in jewellery alloys covered by ISO 9202.
- Standard8 pagesEnglish languagesale 15% off
- Standard8 pagesEnglish languagesale 15% off
- Standard9 pagesFrench languagesale 15% off
- Standard9 pagesFrench languagesale 15% off
This document specifies the technical and functional requirements including test methods for parking terminals. It applies to unattended terminals used to obtain the right to park for visual and / or electronic control of multiple road vehicles, with payment where applicable.
This document only covers parking terminals.
For parking terminals connected to centralised system, this document covers the minimum information to be exchanged with a centralised system. It does not define a standard protocol between parking terminals and centralised systems. It does not define the centralised system.
This document does not cover pay-on-foot terminals.
- Standard65 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a method for the simulation of accelerated wear and corrosion, to be used prior
to the detection of nickel release from coated articles that come into direct and prolonged contact with
the skin. According to the Commission Regulation (EC) No 1907/2006 (REACH), articles with an outer
coating containing nickel and those which are inserted into pierced ears and other parts of the human
body are excluded from the scope of this document.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the terminology, classification and the methods that are used for the grading and description of single unmounted polished diamonds over 0,25 carat (ct). This document applies to natural, unmounted, polished diamonds. It is not to be used for fancy coloured diamonds, synthetic diamonds, treated diamonds (other than is allowed for in 7.4), nor for assembled stones.
- Standard55 pagesEnglish languagesale 15% off
- Standard55 pagesEnglish languagesale 15% off
- Standard55 pagesEnglish languagesale 15% off
- Standard54 pagesFrench languagesale 15% off
- Standard54 pagesFrench languagesale 15% off
- Standard54 pagesFrench languagesale 15% off
This document specifies the terms and definitions, the test methods and the evaluation of results of watch-glasses with anti-reflective treatments. The document is applicable to sapphire watch-glasses with anti-reflective treatments, and it can also be used as a reference for mineral watch-glasses with anti-reflective treatments.
- Standard12 pagesEnglish languagesale 15% off
- Standard12 pagesEnglish languagesale 15% off
- Standard13 pagesFrench languagesale 15% off
- Standard13 pagesFrench languagesale 15% off
This standard specifies the technical and functional requirements and test methods for parking terminals installed on or off-street. It applies to unattended terminals used to obtain the right to park for visual and / or electronic control of an unlimited number of road vehicles, against payment or not.
This standard covers only the terminal aspects of the parking system.
This standard does not cover mobile phone applications or pay-on-foot terminals.
- Standard65 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the terms and definitions, and the signal receiving general measurement method for radio-controlled clocks. It is applicable to the analogical or/and liquid crystal display or/and LED display radio-controlled clocks, and the radio-controlled clock movements can also refer to it.
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesEnglish languagesale 15% off
This document specifies the requirements, test methods, inspection, marking, packaging, transportation, storage, quality certificate and the order (or contract) information of one kilogram gold bars. This document is applicable to one-kilogram cast gold bars produced for investment markets or industrial (jewellery, electronic) markets.
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
- Amendment12 pagesEnglish languagesale 10% offe-Library read for1 day
D135/043: Amendment prepared by CLC/TC 61/WG 4 to answer M/392 (LVD - limitation clause)
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
This document describes an analytical procedure for the determination of platinum in platinum alloys with a nominal content up to 990 ‰ (parts per thousand), including alloys according to ISO 9202.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
This document describes an analytical procedure for the determination of palladium in palladium alloys with a nominal content up to 990 ? (parts per thousand), including alloys according to ISO 9202.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the minimum requirements and test methods for magnetic resistant watches. This document applies to magnetic resistant watches designed to withstand daily magnetic fields. Moreover, it indicates the marking which the manufacturer is authorized to apply to them.
- Standard14 pagesEnglish languagesale 15% off
- Standard14 pagesEnglish languagesale 15% off
- Standard15 pagesFrench languagesale 15% off
- Standard15 pagesFrench languagesale 15% off
This document concerns whole watches, in which all or some of the components of the external parts are made of hard material, with the exception of watch glasses. It applies to all elements made in massive material whose hardness is greater than or equal to 1 200 Vickers. It describes the performance in terms of resistance to mechanical and thermal shocks, to corrosion, to scratches, to sunlight exposure and also to the wear of its components.
- Standard11 pagesEnglish languagesale 15% off
- Standard11 pagesEnglish languagesale 15% off
- Standard11 pagesFrench languagesale 15% off
- Standard11 pagesFrench languagesale 15% off
This document specifies the analytical procedure for the determination of silver with a nominal content of and above 999 ? (parts per thousand). This document specifies a method intended to be used as the recommended method for the determination of silver of fineness of and above 999 ?. For the determination of fineness of and above 999,9 ?, modifications described in Annex B apply.
- Standard9 pagesEnglish languagesale 15% off
- Standard9 pagesEnglish languagesale 15% off
- Standard10 pagesFrench languagesale 15% off
- Standard10 pagesFrench languagesale 15% off
This document specifies the analytical procedure for the determination of gold, platinum and palladium with a nominal content of and above 999 ? (parts per thousand). This document specifies a method intended to be used as the recommended method for the determination of gold, platinum and palladium of fineness of and above 999 ?. For the determination of fineness of and above 999,9 ?, modifications described in Annex B apply.
- Standard10 pagesEnglish languagesale 15% off
- Standard10 pagesEnglish languagesale 15% off
- Standard11 pagesFrench languagesale 15% off
- Standard11 pagesFrench languagesale 15% off
This document specifies the precious metal content in solders suitable for use in the production of jewellery made of precious metal alloys.
- Standard3 pagesEnglish languagesale 15% off
- Standard3 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
- Standard4 pagesFrench languagesale 15% off