prEN IEC 60335-2-64:2026
(Main)Safety of household and similar electrical appliances - Part 2-64: Particular requirements for commercial electric kitchen machines
General Information
- Abstract
This standard deals with the safety of electrically operated commercial kitchen machines, their rated voltage being not more than 250 V for single phase appliances connected between one phase and neutral, and 480 V for other appliances including direct current (DC) supplied appliances and battery operated appliances. These appliances are not intended for household and similar purposes. They are used for commercial processing of food in areas not open to the public, for example in kitchens of restaurants, canteens, hospitals and in commercial enterprises such as bakeries and butcheries
- Status
- Not Published
- Publication Date
- 26-Oct-2027
- Technical Committee
- CLC/TC 61 - Safety of household and similar electrical appliances
- Drafting Committee
- CLC/TC 61/WG 06 - Activities related to the new MD
- Current Stage
- 4020 - Enquiry circulated - Enquiry
- Start Date
- 03-Jul-2026
- Due Date
- 21-Apr-2026
- Completion Date
- 03-Jul-2026
Relations
- Effective Date
- 07-Apr-2025
- Effective Date
- 07-Apr-2025
- Effective Date
- 01-Apr-2025
- Effective Date
- 01-Apr-2025
Frequently Asked Questions
prEN IEC 60335-2-64:2026 is a draft published by CLC. Its full title is "Safety of household and similar electrical appliances - Part 2-64: Particular requirements for commercial electric kitchen machines". This standard covers: This standard deals with the safety of electrically operated commercial kitchen machines, their rated voltage being not more than 250 V for single phase appliances connected between one phase and neutral, and 480 V for other appliances including direct current (DC) supplied appliances and battery operated appliances. These appliances are not intended for household and similar purposes. They are used for commercial processing of food in areas not open to the public, for example in kitchens of restaurants, canteens, hospitals and in commercial enterprises such as bakeries and butcheries
This standard deals with the safety of electrically operated commercial kitchen machines, their rated voltage being not more than 250 V for single phase appliances connected between one phase and neutral, and 480 V for other appliances including direct current (DC) supplied appliances and battery operated appliances. These appliances are not intended for household and similar purposes. They are used for commercial processing of food in areas not open to the public, for example in kitchens of restaurants, canteens, hospitals and in commercial enterprises such as bakeries and butcheries
prEN IEC 60335-2-64:2026 is classified under the following ICS (International Classification for Standards) categories: 97.040.10 - Kitchen furniture. The ICS classification helps identify the subject area and facilitates finding related standards.
prEN IEC 60335-2-64:2026 has the following relationships with other standards: It is inter standard links to prEN IEC 60335-2-64:2026/prA1:2026, prEN IEC 60335-2-64:2026/prAA:2026, EN 60335-2-64:2000, EN 60335-2-64:2000/A1:2002. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
prEN IEC 60335-2-64:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/53/EU, 2023/1230; Standardization Mandates: M/536, M/605. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
prEN IEC 60335-2-64:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2026
Varnost gospodinjskih in podobnih električnih aparatov - 2-64. del: Posebne
zahteve za komercialne električne kuhinjske stroje
Safety of household and similar electrical appliances - Part 2-64: Particular requirements
for commercial electric kitchen machines
Sicherheit elektrischer Geräte für den Hausgebrauch und ähnliche Zwecke - Teil 2-64:
Besondere Anforderungen für elektrische Küchenmaschinen für den gewerblichen
Gebrauch
Appareils électrodomestiques et analogues - Sécurité - Partie 2-64: Exigences
particulières pour les machines de cuisine électriques à usage commercial
Ta slovenski standard je istoveten z: prEN IEC 60335-2-64:2026
ICS:
97.040.50 Majhni gospodinjski aparati Small kitchen appliances
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD DRAFT
prEN IEC 60335-2-64
NORME EUROPÉENNE
EUROPÄISCHE NORM
July 2026
ICS 97.040.10 Will supersede EN 60335-2-64:2000; EN 60335-2-
64:2000/corrigendum Jun. 2002; EN 60335-2-
64:2000/A1:2002
English Version
Safety of household and similar electrical appliances - Part 2-64:
Particular requirements for commercial electric kitchen machines
(IEC 60335-2-64:2021)
Appareils électrodomestiques et analogues - Sécurité - Sicherheit elektrischer Geräte für den Hausgebrauch und
Partie 2-64: Exigences particulières pour les machines de ähnliche Zwecke - Teil 2-64: Besondere Anforderungen für
cuisine électriques à usage commercial elektrische Küchenmaschinen für den gewerblichen
(IEC 60335-2-64:2021) Gebrauch
(IEC 60335-2-64:2021)
This draft European Standard is submitted to CENELEC members for enquiry.
Deadline for CENELEC: 2026-09-25.
The text of this draft consists of the text of IEC 60335-2-64:2021.
If this draft becomes a European Standard, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to
the CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 81640 Ref. No. prEN IEC 60335-2-64:2026 E
1 European foreword
2 This document (prEN IEC 60335-2-64:2026) consists of the text of IEC 60335-2-64:2021 prepared by
3 IEC/TC 61 "Safety of household and similar electrical appliances".
4 This document is currently submitted to the Enquiry.
5 The following dates are proposed:
• latest date by which the existence of this (doa) dav + 6 months
document has to be announced at national
level
• latest date by which this document has to be (dop) dav + 12 months
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) dav + 36 months
conflicting with this document have to be (to be confirmed or
withdrawn modified when voting)
6 This document will supersede EN 60335-2-64:2000 and all of its amendments and corrigenda (if any).
7 This document is read in conjunction with prEN IEC 60335-2-64:2026/prA1:2026 and prEN IEC 60335-2-
8 64:2026/prAA:2026.
9 This document has been prepared under a standardization request addressed to CENELEC by the European
10 Commission. The Standing Committee of the EFTA State subsequently approves these requests for its
11 Member States.
12 For relationship with EU legislation, see informative Annexes ZZB and ZZC, which are an integral part of
13 prEN IEC 60335-2-64:2026/prAA:2026.
IEC 60335-2-64 ®
Edition 4.0 2021-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Household and similar electrical appliances – Safety –
Part 2-64: Particular requirements for commercial electric kitchen machines
Appareils électrodomestiques et analogues – Sécurité –
Partie 2-64: Exigences particulières pour les machines de cuisine électriques
à usage commercial
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 97.040.10 ISBN 978-2-8322-1045-1
– 2 – IEC 60335-2-64:2021 © IEC 2021
CONTENTS
FOREWORD . 4
INTRODUCTION . 7
1 Scope . 8
2 Normative references . 9
3 Terms and definitions . 9
4 General requirement . 11
5 General conditions for the tests . 11
6 Classification . 11
7 Marking and instructions . 12
8 Protection against access to live parts . 14
9 Starting of motor-operated appliances . 14
10 Power input and current . 14
11 Heating . 15
12 Charging metal-ion batteries . 15
13 Leakage current and electric strength at operating temperature . 15
14 Transient overvoltages . 16
15 Moisture resistance . 16
16 Leakage current and electric strength . 17
17 Overload protection of transformers and associated circuits . 17
18 Endurance . 17
19 Abnormal operation . 17
20 Stability and mechanical hazards . 18
21 Mechanical strength . 23
22 Construction . 24
23 Internal wiring . 26
24 Components . 26
25 Supply connection and external flexible cords . 26
26 Terminals for external conductors . 27
27 Provision for earthing . 27
28 Screws and connections . 27
29 Clearances, creepage distances and solid insulation . 28
30 Resistance to heat and fire . 28
31 Resistance to rusting . 29
32 Radiation, toxicity and similar hazards . 29
Annexes . 31
Annex B (normative) Battery-operated appliances, separable batteries and detachable
batteries for battery-operated appliances . 32
Annex P (informative) Guidance for the application of this standard to appliances used
in tropical climates . 33
Bibliography . 34
Figure 101 – Splash apparatus . 29
IEC 60335-2-64:2021 © IEC 2021 – 3 –
Figure 102 – Protection devices for slicing machines . 30
Table 101 – Assembling torques for screwed connections providing earthing continuity . 28
– 4 – IEC 60335-2-64:2021 © IEC 2021
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –
SAFETY –
Part 2-64: Particular requirements for commercial
electric kitchen machines
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC Publication(s)"). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
rights. IEC shall not be held responsible for identifying any or all such patent rights.
IEC 60335-2-64 has been prepared by IEC technical committee 61: Safety of household and
similar electrical appliances. It is an International Standard.
This fourth edition cancels and replaces the third edition published in 2002, Amendment 1: 2007
and Amendment 2:2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous
edition:
a) the text has been aligned with IEC 60335-1:2020;
b) some notes have been converted to normative text, modified or deleted (1, 7.12, 9.101,
10.1, 11.7, 15.3, 20.2, 20.116, 20.117, 20.117.2, 20.117.3, 20.119, 22.101, 23.3, 27.2);
c) clarifications to some test specifications have been made (9.101, 15.1.1, 15.2, 22.113);
d) exclusion of appliances used in areas open to the public (Clause 1);
IEC 60335-2-64:2021 © IEC 2021 – 5 –
e) clarification of requirements for battery-operated appliances (Clause 1, 11.7, B.3.1.1,
B.11.1);
f) relocation of cleaning instructions from 7.12.1 to 7.12;
g) conciliation of the text of IEC 60335-2-64 with other standards under IEC/TC61/MT32.
The text of this International Standard is based on the following documents:
Draft Report on voting
61/6372/FDIS 61/6422/RVD
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/standardsdev/publications.
A list of all parts of the IEC 60335 series, under the general title Household and similar electrical
appliances – Safety, can be found on the IEC website.
This Part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its
amendments unless that edition precludes it; in that case, the latest edition that does not
preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.
NOTE 1 When "Part 1" is mentioned in this standard, it refers to IEC 60335-1.
This Part 2 supplements or modifies the corresponding clauses in IEC 60335-1, so as to convert
that publication into the IEC standard: Particular requirements for commercial electric kitchen
machines.
When a particular subclause of Part 1 is not mentioned in this Part 2, that subclause applies as
far as is reasonable. When this standard states "addition", "modification" or "replacement", the
relevant text in Part 1 is to be adapted accordingly.
NOTE 2 The following numbering system is used:
– subclauses, tables and figures that are numbered starting from 101 are additional to those in Part 1;
– unless notes are in a new subclause or involve notes in Part 1, they are numbered starting from 101, including
those in a replaced clause or subclause;
– additional annexes are lettered AA, BB, etc.
NOTE 3 The following print types are used:
– requirements: in roman type;
– test specifications: in italic type;
– notes: in small roman type.
Words in bold in the text are defined in Clause 3. When a definition concerns an adjective, the adjective and the
associated noun are also in bold .
– 6 – IEC 60335-2-64:2021 © IEC 2021
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
NOTE 4 The attention of National Committees is drawn to the fact that equipment manufacturers and testing
organizations may need a transitional period following publication of a new, amended or revised IEC publication in
which to make products in accordance with the new requirements and to equip themselves for conducting new or
revised tests.
It is the recommendation of the committee that the content of this publication be adopted for implementation nationally
not earlier than 12 months or later than 36 months from the date of publication.
The following differences exist in the countries indicated below.
– 6.1: Class 01 appliances are allowed if their rated voltage does not exceed 150 V (Japan).
– 13.2: Leakage current limits are different (Japan).
– 16.2: Leakage current limits are different (Japan).
IEC 60335-2-64:2021 © IEC 2021 – 7 –
INTRODUCTION
It has been assumed in the drafting of this International Standard that the execution of its
provisions is entrusted to appropriately qualified and experienced persons.
Guidance documents concerning the application of the safety requirements for appliances can
be accessed via TC 61 supporting documents on the IEC website –
https://www.iec.ch/tc61/supportingdocuments
This information is given for the convenience of users of this International Standard and does
not constitute a replacement for the normative text in this standard.
This standard recognizes the internationally accepted level of protection against hazards such
as electrical, mechanical, thermal, fire and radiation of appliances when operated as in normal
use taking into account the manufacturer's instructions. It also covers abnormal situations that
can be expected in practice and takes into account the way in which electromagnetic
phenomena can affect the safe operation of appliances.
This standard takes into account the requirements of IEC 60364 as far as possible so that there
is compatibility with the wiring rules when the appliance is connected to the supply mains.
However, national wiring rules may differ.
If an appliance within the scope of this standard also incorporates functions that are covered
by another Part 2 of IEC 60335, the relevant Part 2 is applied to each function separately, as
far as is reasonable. If applicable, the influence of one function on the other is taken into
account.
When a Part 2 standard does not include additional requirements to cover hazards dealt with
in Part 1, Part 1 applies.
NOTE 1 This means that the technical committees responsible for the Part 2 standards have determined that it is
not necessary to specify particular requirements for the appliance in question over and above the general
requirements.
This standard is a product family standard dealing with the safety of appliances and takes
precedence over horizontal and generic standards covering the same subject.
NOTE 2 Horizontal publications, basic safety publications and group safety publications covering a hazard are not
applicable since they have been taken into consideration when developing the general and particular requirements
for the IEC 60335 series of standards.
An appliance that complies with the text of this standard will not necessarily be considered to
comply with the safety principles of the standard if, when examined and tested, it is found to
have other features that impair the level of safety covered by these requirements.
An appliance employing materials or having forms of construction differing from those detailed
in the requirements of this standard may be examined and tested according to the intent of the
requirements and, if found to be substantially equivalent, may be considered to comply with the
standard.
NOTE 3 Standards dealing with non-safety aspects of household appliances are:
– IEC standards published by TC 59 concerning methods for measuring performance;
– CISPR 11, CISPR 14-1 and relevant IEC 61000-3 series standards concerning electromagnetic emissions;
– CISPR 14-2 concerning electromagnetic immunity;
– IEC standards published by TC 111 concerning environmental matters.
– 8 – IEC 60335-2-64:2021 © IEC 2021
HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES –
SAFETY –
Part 2-64: Particular requirements for commercial
electric kitchen machines
1 Scope
This clause of Part 1 is replaced by the following.
This part of IEC 60335 deals with the safety of electrically operated commercial kitchen
machines, their rated voltage being not more than 250 V for single phase appliances
connected between one phase and neutral, and 480 V for other appliances including direct
current (DC) supplied appliances and battery operated appliances.
These appliances are not intended for household and similar purposes. They are used for
commercial processing of food in areas not open to the public, for example in kitchens of
restaurants, canteens, hospitals and in commercial enterprises such as bakeries and
butcheries.
Examples of kitchen machines are
– mixers;
– liquid or food blenders;
– kneaders;
– beaters;
– shredders;
– graters;
– mincers;
– slicers;
– peelers;
– tin openers;
– coffee grinders;
– machines used for washing and/or drying food;
– portioning machines;
– pastry rollers;
– noodle strip cutters;
– food processors;
– beam mixers.
This standard also applies to appliances which, in order to facilitate transport, are supplied in
several parts (sub-assemblies) which, when assembled at the place of installation, form a
constructional unit without the use of any additional parts.
The electrical part of appliances making use of other forms of energy is also within the scope
of this standard.
IEC 60335-2-64:2021 © IEC 2021 – 9 –
As far as is practicable, this standard deals with the common hazards presented by these types
of appliances.
Attention is drawn to the fact that
– for appliances intended to be used in vehicles or on board ships or aircraft, additional
requirements can be necessary;
– in many countries, additional requirements are specified by the national health authorities,
the national authorities responsible for the protection of labour, the national water supply
authorities and similar authorities.
This standard does not apply to
– appliances designed exclusively for industrial purposes;
– appliances intended to be used in locations where special conditions prevail, such as the
presence of a corrosive or explosive atmosphere (dust, vapour or gas);
– appliances for continuous mass production of food;
– independent conveying equipment, such as food distribution belts.
2 Normative references
This clause of Part 1 is applicable except as follows.
Addition:
ISO 898-1, Mechanical properties of fasteners made of carbon steel and alloy steel – Part 1:
Bolts, screws and studs with specified property classes – Coarse thread and fine pitch thread
ISO 3506-1, Fasteners – Mechanical properties of corrosion-resistant stainless steel fasteners
– Part 1: Bolts, screws and studs with specified grades and property classes
ISO 3506-2, Fasteners – Mechanical properties of corrosion-resistant stainless steel fasteners
– Part 2: Nuts with specified grades and property classes
ISO 3506-3, Mechanical properties of corrosion-resistant stainless steel fasteners – Part 3: Set
screws and similar fasteners not under tensile stress
ISO 3506-4, Mechanical properties of corrosion-resistant stainless steel fasteners – Part 4:
Tapping screws
3 Terms and definitions
This clause of Part 1 is applicable except as follows.
3.1 Definitions relating to physical characteristics
3.1.4 Addition:
Note 101 to entry: The rated power input is the sum of the power inputs of all the individual elements in the
appliance that can be on at one time; where there are several such combinations possible, that giving the highest
power input is used in determining the rated power input.
– 10 – IEC 60335-2-64:2021 © IEC 2021
3.1.9 Addition:
operation of the appliance under the following conditions:
The appliance is operated without load. The appliance is then loaded in appropriate steps, the
supply voltage being maintained at its original value. For each step, steady conditions have to
be established before increasing the load. This operation is repeated until just before an
overload release operates, or until the steady condition with the highest temperature has been
attained.
Note 101 to entry: The load may be achieved by using an electrical or mechanical brake.
Where it is not possible or is impractical to apply effectively an electrical or mechanical brake,
the load is 115 % of the input measured when the appliance is operated without load at rated
voltage and normal operating temperature, and with controls intended to be adjusted by the
user set at maximum.
Note 102 to entry: Examples of such appliances are
– liquid blenders;
– slicers;
– peelers;
– coffee grinders;
– machines used for washing and/or drying food;
– portioning machines.
3.6 Definitions relating to parts of an appliance
3.6.101
guard plate
plate similar to a slice thickness plate, fitted to machines with automatic product feeding
3.6.102
product holder
support for the product to be sliced
Note 1 to entry: The product holder can be equipped with a pusher or a feed carriage and/or a clamping device
3.6.103
sliding feed table
device that supports the product holder and allows it to move forwards and backwards
3.6.104
feed carriage
device on which the product is placed and that slides on top of the product holder in order to
move the product towards the blade
3.6.105
pusher
device used to move the product along the product holder against the thickness plate
3.6.106
last slice device
plate with which the last portion of the product is fed to the cutting blade
Note 1 to entry: The plate can be fitted on the pusher, clamping device or feed carriage.
3.8 Definitions relating to miscellaneous matters
3.8.101
indicated level
mark on the appliance to indicate the maximum liquid level for correct operation
IEC 60335-2-64:2021 © IEC 2021 – 11 –
3.8.102
installation wall
special fixed construction containing supply facilities for appliances installed in conjunction with
it
4 General requirement
This clause of Part 1 is applicable.
5 General conditions for the tests
This clause of Part 1 is applicable except as follows.
5.10 Addition:
Appliances intended for installation in a bank of other appliances and appliances intended to
be fixed to an installation wall are enclosed to obtain protection against electric shock and
harmful ingress of water equivalent to that obtained when installed in accordance with the
instructions provided with the appliance.
NOTE Appropriate enclosures or additional appliances can be needed for test purposes.
5.101 Appliances are tested as heating appliances when during a mode of operation
electrical heaters are energized. If no electrical heaters are energized, the appliances are tested
as motor-operated appliances.
5.102 Appliances, when assembled in combination with or incorporating other appliances, are
tested in accordance with the requirements of this standard. The other appliances are operated
simultaneously in accordance with the requirements of the relevant standards.
6 Classification
This clause of Part 1 is applicable except as follows.
6.1 Replacement:
Hand-held appliances shall be class II or class III with respect to protection against electric
shock. Other appliances shall be class I, class II or class III with respect to protection against
electric shock.
Compliance is checked by inspection and by the relevant tests.
6.2 Addition:
Appliances shall be at least IPX1 with respect to protection against harmful ingress of water.
– 12 – IEC 60335-2-64:2021 © IEC 2021
7 Marking and instructions
This clause of Part 1 is applicable except as follows.
7.1 Addition:
If the appliance is marked with rated "on" and "off" periods, the marking shall correspond to
normal use. The marking of the "on" period shall precede the marking of the "off" period, both
markings being separated by an oblique stroke.
If the reversal of a motor could cause a hazard, then the direction of rotation should be clearly
and visibly indicated on the motor, if the direction of rotation depends on the way the motor is
connected to the supply.
7.12 Addition:
The instructions for use shall include the operating times and speed settings for accessories,
unless this information is marked on the appliance.
The instructions for use shall warn against misuse, and shall state that care is needed when
handling cutting blades during cleaning.
Instructions for user maintenance, for example cleaning, shall also be given. They shall include
a statement that the appliance is not to be cleaned with a water jet or a steam cleaner. The
instructions for use shall contain instructions for cleaning of all surfaces coming into contact
with food during normal use.
Operating instructions included in the operating manual shall clearly indicate how to use
particular or special safeguards provided with the appliance, and shall draw the attention of the
user to any remaining hazards and give information about preventative measures to be taken
by the user for the safe use of the appliance.
NOTE 101 Examples of appliances with remaining hazards are those that are not subjected to the test with the test
probe in 20.2.
Information shall also be given about the correct assembly and safe use of accessories provided
with the appliance and, if relevant, about possible hazards that might arise when using
accessories other than those provided with the appliance. The instructions for use shall warn
the user to use a suitable bowl with attachable accessories such as egg beaters and sieving
machines, and shall indicate that the accessory must not project from the upper part of the
bowl.
The instructions for use for hand-held blenders and whisks shall contain a warning against the
use of these appliances when not in contact with the product.
The instructions for use for food processors shall state that care is needed when handling
cutting blades, especially when removing the blades from the bowl, emptying the bowl and
during cleaning.
The instructions for use for mincers, where the required safety at the discharge outlets depends
entirely on perforated discs provided with the appliance, shall contain a warning against use of
perforated discs with oval shaped holes or holes of a greater diameter.
The instructions for use for slicers shall give details for assembly and removal of blades and
shall require that the slice thickness plate or guard plate shall be set to the zero position during
the cleaning of the blade while still installed in the appliance.
IEC 60335-2-64:2021 © IEC 2021 – 13 –
The instructions for use shall identify separate sharpening devices suitable for use with the
appliance, and shall state that only those devices shall be used. A code or similar means may
be used for identification purposes.
If symbol IEC 60417-5021 (2002-10) is marked on the appliance, its meaning shall be
explained.
The instructions shall include the substance of the following:
These appliances are intended to be used for commercial applications, for example in
kitchens of restaurants, canteens, hospitals and in commercial enterprises such as bakeries
and butcheries, but not for continuous mass production of food.
If the manufacturer wants to limit the use of the appliance to less than the above, this has to
be clearly stated in the instructions.
Modification:
The instruction concerning persons (including children) with reduced physical, sensory or
mental capabilities or lack of experience and knowledge and children playing with the appliance
is not applicable.
7.12.1 Addition:
The appliance shall be accompanied by instructions detailing any special precautions necessary
for installation. For appliances intended for installation in a bank of other appliances, and
appliances intended to be fixed to an installation wall, details of how to ensure appropriate
protection against electric shock and harmful ingress of water shall be supplied. If the controls
of more than one appliance are combined in a separate enclosure, detailed installation
instructions shall be supplied.
For appliances that are permanently connected to fixed wiring, and for which leakage currents
can exceed 10 mA, particularly if disconnected or not used for long periods, or during initial
installation, the instructions shall give recommendations regarding the rating of protective
devices, such as residual current devices (RCDs), to be installed.
If a stationary appliance is intended to be moved for cleaning, this shall be stated.
For stationary appliances equipped with rollers or castors or intended to be moved for
cleaning, the instructions shall state the substance of the following.
This appliance is to be connected with flexible connections for equipotential bonding and
connection to services such as electricity supply, water supply, gas supply and steam supply
such that the appliance can be moved in the direction required for cleaning a distance not
less than the dimension of the appliance in the direction of movement plus 500 mm without
the flexible connections becoming taut or being subject to strain.
Compliance is checked by inspection.
7.12.9 Not applicable.
7.101 Equipotential bonding terminals shall be marked with symbol
IEC 60417-5021 (2002-10).
These markings shall not be placed on screws, removable washers or other parts that can be
removed when conductors are being connected.
– 14 – IEC 60335-2-64:2021 © IEC 2021
Compliance is checked by inspection.
7.102 Containers intended to be filled by hand or by a manually operated tap shall be marked
with an indicated level.
Compliance is checked by inspection.
8 Protection against access to live parts
This clause of Part 1 is applicable.
9 Starting of motor-operated appliances
This clause of Part 1 is applicable except as follows.
9.101 Motors incorporated in the appliance shall start within 3 s, if delayed starting could result
in a hazard.
Fan motors providing a cooling effect in order to comply with the requirements of Clause 11
shall start under all voltage conditions that can occur in use.
Compliance is checked by the following tests using a supply source such that its drop in voltage
does not exceed 1 % during the tests. The appliance is returned to room temperature after
each test.
The appliance is started under the conditions occurring at the beginning of normal operation
or, for automatic appliances, at the beginning of the normal cycle of operation, a voltage equal
to 0,85 times rated voltage being applied to the input terminals of the appliance. For appliances
provided with motors having other than centrifugal starting switches, this test is repeated at a
voltage equal to 1,06 times rated voltage being applied to the input terminals of the appliance.
The tests are carried out three times.
In all cases, the motor shall start and it shall function in such a way that safety is not affected,
and the overload protective devices of the motor shall not operate.
10 Power input and current
This clause of Part 1 is applicable except as follows.
10.1 Addition:
For appliances having more than one heating unit that can be on at the same time, the total
power input may be determined by measuring the power input of each heating unit separately
(see also 3.1.4).
IEC 60335-2-64:2021 © IEC 2021 – 15 –
11 Heating
This clause of Part 1 is applicable except as follows.
11.2 Addition:
Appliances intended to be fixed to the floor, and appliances with a mass greater than 40 kg and
not provided with rollers, castors or similar means, are installed in accordance with the
manufacturer's instructions. If no instructions are given, these appliances are considered as
appliances normally placed on the floor.
11.7 Modification:
Appliances are operated until steady conditions are established.
The duration of the test may consist of more than one cycle of operation. If the appliance is
marked with rated "on" and "off" periods, they are taken into account.
For appliances incorporating integral batteries or separable batteries not disconnected from
the appliance for charging purposes:
– the battery that has been fully discharged is charged for 1 h, while the appliance is
operated as specified, if allowed by the construction of the appliance;
– the battery that has been fully discharged is charged, for a duration of 24 h or until it is
fully charged whichever is shorter, without the battery-operated appliance performing its
intended function.
12 Charging metal-ion batteries
This clause of Part 1 is applicable.
13 Leakage current and electric strength at operating temperature
This clause of Part 1 is applicable except as follows.
13.2 Modification:
Instead of the permissible leakage current for stationary class I appliances, the following
applies:
– for cord and plug connected 0,75 mA or 1 mA per kW rated power input of the
appliances appliance with a maximum of 10 mA, whichever is higher;
– for other appliances 0,75 mA or 1 mA per kW rated power input of the
appliance with no maximum, whichever is higher.
For portable class I appliances, instead of the permissible leakage current, the following
applies:
– for cord and plug connected 0,75 mA or 1 mA per kW rated power input of the
appliances appliance with a maximum of 10 mA, whichever is higher.
– 16 – IEC 60335-2-64:2021 © IEC 2021
14 Transient overvoltages
This clause of Part 1 is applicable.
15 Moisture resistance
This clause of Part 1 is applicable except as follows.
15.1.1 Addition:
In addition, appliances, except those marked IPX5 and IPX6, are subjected for 5 min to the
following splash test.
The apparatus shown in Figure 101 is used. The appliance is placed in the normal position of
use and adjustable feet shall be set in accordance with the instructions for use in the most
unfavourable height.
For appliances normally used on the floor, the bowl is placed on the floor and is moved around
in such a way as to splash the appliance from all directions. During the test, the water pressure
is so regulated that the water splashes up 150 mm above the bottom of the bowl. The bowl is
not positioned underneath the appliance.
For all other appliances, the bowl is placed on the same plane where the appliance is placed
and is moved around in such a way as to splash the appliance from all directions. During the
test, the water pressure is so regulated that the water splashes up 100 mm above the bottom
of the bowl. The bowl is not positioned underneath the appliance.
Care is taken that the appliance is not hit by the direct jet.
15.1.2 Modification:
Appliances normally used on a table are placed on a support having dimensions that are
15 cm ± 5 cm in excess of those of the orthogonal projection of the appliance on the support.
15.2 Modification:
Water outlets, if any, are blocked.
The water containers of appliances intended to be filled with water by hand are completely filled
with the spillage solution and a further quantity, equal to 15 % of the capacity of the container
but not more than 10 l, is poured in steadily over a period of 1 min.
Appliances intended to be filled by a manually operated tap or automatically are connected to
a water supply having the maximum supply pressure indicated by the manufacturer. The means
for controlling the incoming water is held fully open, and the filling continued for 1 min after the
first evidence of overflow, or until a further protective system operates to stop the inflow.
With the container filled with water, the appliance is then operated at rated voltage for 15 s.
Lids or covers are in position or removed, whichever is the most unfavourable.
15.3 Addition:
If it is not possible to place the whole appliance in the humidity cabinet, parts containing
electrical components are tested separately, taking into account the conditions that occur in the
appliance.
IEC 60335-2-64:2021 © IEC 2021 – 17 –
15.101 Appliances that are provided with a tap intended for filling or cleaning shall be
constructed so that the water from the tap cannot come into contact with live parts.
Compliance is checked by the following test.
The tap is fully opened for 1 min with the appliance connected to a water supply
...