Lighting equipment - Non-active mode power measurement

IEC 63103:2020(E) specifies methods of measurement of electrical power consumption in non-active mode(s), as applicable for electrical lighting equipment. This includes electrical lighting equipment incorporating non-illumination components. This document specifies neither performance requirements nor limits on power consumption. This document applies to lighting equipment connected to a supply voltage up to 1 500 V DC or up to 1 000 V AC. This document is intended to be referenced by lighting equipment product standards for the measurement of non-active mode power consumption. Details for the non-active mode power consumption measurement and data presentation are specified in the product standards.

Beleuchtungseinrichtungen - Messung der elektrischen Leistungsaufnahme im nicht-aktiven Betrieb

Appareils d'éclairage - Mesure de puissance en mode non actif

L'IEC 63103:2020 spécifie les méthodes de mesure de la consommation de puissance électrique dans le ou les modes non actifs, selon le cas, des appareils d'éclairage électriques. Sont inclus les appareils d'éclairage électriques qui comprennent des composants non éclairants. Le présent document ne spécifie ni les exigences de performance ni les limites concernant la consommation de puissance. Le présent document s'applique aux appareils d'éclairage reliés à une tension d'alimentation allant jusqu'à 1 500 V en courant continu ou jusqu'à 1 000 V en courant alternatif. Le présent document est destiné à être référencé dans les normes de produits des appareils d'éclairage pour le mesurage de la consommation de puissance en mode non actif. Les détails concernant le mesurage de la consommation de puissance en mode non actif et la présentation des données sont spécifiés dans les normes de produits. La présente version bilingue (2021-07) correspond à la version anglaise monolingue publiée en 2020-07. La version française de cette norme n'a pas été soumise au vote.

Oprema za razsvetljavo - Neaktivno merjenje moči (IEC 63103:2020)

General Information

Status
Published
Publication Date
10-Sep-2020
Drafting Committee
IEC/TC 34 - IEC_TC_34
Current Stage
6060 - Document made available - Publishing
Start Date
11-Sep-2020
Completion Date
11-Sep-2020

Overview

EN IEC 63103:2020 (IEC 63103:2020) specifies accepted methods for measuring electrical non-active mode power (commonly called standby or idle power) for electrical lighting equipment. It applies to luminaires and lighting components - including products that incorporate non-illumination functions - connected to supplies up to 1 500 V DC or 1 000 V AC. The document defines test conditions and measurement procedures but does not set performance limits or power consumption thresholds. It is intended to be referenced by product standards for consistent measurement and reporting of non-active mode power consumption.

Key Topics

  • Scope and applicability: Measurement methods for illumination-only and multi-function lighting equipment; includes devices with integrated control, sensors or communication modules.
  • General test conditions: Laboratory/environmental requirements, supply voltage and waveform considerations.
  • Power measurement accuracy and uncertainty: Requirements for measurement instruments and uncertainty assessment to ensure repeatable results.
  • Network aspects: Treatment of wired and wireless networked devices; guidance for conducted and radiated testing and calibration when integral antennas or RF interfaces are present.
  • Equipment under test (EUT): Definitions and preparation steps for different EUT categories (illumination-only vs multi-function) and recommended measurement points.
  • Measuring procedures: Several permitted approaches - direct meter reading, average-reading, and sampling methods - and templates for reporting measured non-active mode power.
  • Measurement setups: Normative annexes provide schematic setups (Annex B and C) for typical configurations and controlgear examples; figures illustrate conducted/radiated test arrangements and calibration methods.

Applications

Who uses EN IEC 63103:2020 and why:

  • Manufacturers and product designers: To design lighting products that meet industry measurement practices for standby power and to prepare technical documentation.
  • Test laboratories: To perform repeatable non-active mode power measurements for product certification or internal verification.
  • Standards writers and regulatory bodies: To reference consistent measurement methods in product standards or energy efficiency programs.
  • System integrators & specifiers: To assess real-world energy impact of networked luminaires, sensors, and multi-function lighting systems.
  • Quality and compliance teams: For consistent reporting of standby/idle power in datasheets and compliance reports.

Keywords for search: EN IEC 63103:2020, non-active mode power measurement, standby power, lighting equipment, luminaire testing, networked standby, measurement uncertainty, conducted/radiated testing.

Related Standards

Relevant references and harmonized standards cited in EN IEC 63103:2020 include:

  • IEC 61347-1, IEC 62301 (EN 50564), IEC 62386 series, IEC 62442 series, IEC 62722-1, IEC 60050-845, IEC 62504, and ETSI EN 300 328. These are commonly used together when specifying lighting product test and reporting requirements.
Standard

EN IEC 63103:2020 - BARVE

English language
36 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

EN IEC 63103:2020 is a standard published by CLC. Its full title is "Lighting equipment - Non-active mode power measurement". This standard covers: IEC 63103:2020(E) specifies methods of measurement of electrical power consumption in non-active mode(s), as applicable for electrical lighting equipment. This includes electrical lighting equipment incorporating non-illumination components. This document specifies neither performance requirements nor limits on power consumption. This document applies to lighting equipment connected to a supply voltage up to 1 500 V DC or up to 1 000 V AC. This document is intended to be referenced by lighting equipment product standards for the measurement of non-active mode power consumption. Details for the non-active mode power consumption measurement and data presentation are specified in the product standards.

IEC 63103:2020(E) specifies methods of measurement of electrical power consumption in non-active mode(s), as applicable for electrical lighting equipment. This includes electrical lighting equipment incorporating non-illumination components. This document specifies neither performance requirements nor limits on power consumption. This document applies to lighting equipment connected to a supply voltage up to 1 500 V DC or up to 1 000 V AC. This document is intended to be referenced by lighting equipment product standards for the measurement of non-active mode power consumption. Details for the non-active mode power consumption measurement and data presentation are specified in the product standards.

EN IEC 63103:2020 is classified under the following ICS (International Classification for Standards) categories: 29.140.01 - Lamps in general; 29.140.99 - Other standards related to lamps. The ICS classification helps identify the subject area and facilitates finding related standards.

You can purchase EN IEC 63103:2020 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.

Standards Content (Sample)


SLOVENSKI STANDARD
01-november-2020
Oprema za razsvetljavo - Neaktivno merjenje moči (IEC 63103:2020)
Lighting equipment - Non-active mode power measurement (IEC 63103:2020)
Beleuchtungskomponente - Messung der elektrischen Leistungsaufnahme im
Bereitschafts-Betrieb (nicht-aktiv-Betrieb) (IEC 63103:2020)
Appareils d'éclairage - Mesure de puissance en mode non actif (IEC 63103:2020)
Ta slovenski standard je istoveten z: EN IEC 63103:2020
ICS:
29.140.01 Žarnice na splošno Lamps in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN IEC 63103

NORME EUROPÉENNE
EUROPÄISCHE NORM
September 2020
ICS 29.140.01; 29.140.99
English Version
Lighting equipment - Non-active mode power measurement
(IEC 63103:2020)
Appareils d'éclairage - Mesure de puissance en mode non Beleuchtungskomponente - Messung der elektrischen
actif Leistungsaufnahme im Bereitschafts-Betrieb (nicht-aktiv-
(IEC 63103:2020) Betrieb)
(IEC 63103:2020)
This European Standard was approved by CENELEC on 2020-08-26. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 63103:2020 E
European foreword
The text of document 34/698/FDIS, future edition 1 of IEC 63103, prepared by IEC/TC 34 "Lighting"
was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2021-05-26
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2023-08-26
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Endorsement notice
The text of the International Standard IEC 63103:2020 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards
indicated:
IEC 61347-1:2015 NOTE Harmonized as EN 61347-1:2015 (not modified)
IEC 62301:2011 NOTE Harmonized as EN 50564:2011
IEC 62386 (series) NOTE Harmonized as EN IEC 62386 (series)
IEC 62442 (series) NOTE Harmonized as EN IEC 62442 (series)
IEC 62722-1 NOTE Harmonized as EN 62722-1
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1  Where an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2  Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60050-845 -  International Electrotechnical Vocabulary. - -
Lighting
IEC 62504 -  General lighting - Light emitting diode EN 62504 -
(LED) products and related equipment -
Terms and definitions
IIEC TS 63105 - Lighting systems and related equipment –
Vocabulary1
ETSI EN 300 32820 16 Wideband transmission systems; Data - -
V2.1.1 (2016-11) transmission equipment operating in the
2,4 GHz ISM band and using wide band
modulation techniques; Harmonised
Standard covering the essential
requirements of article 3.2 of Directive
2014/53/EU
Under preparation. Stage at time of publication: IEC CDTS 63105:2020.
IEC 63103 ®
Edition 1.0 2020-07
INTERNATIONAL
STANDARD
colour
inside
Lighting equipment – Non-active mode power measurement

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
ICS 29.140.01; 29.140.99 ISBN 978-2-8322-8648-7

– 2 – IEC 63103:2020 © IEC 2020
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 8
2 Normative references . 8
3 Terms and definitions . 8
4 General test conditions . 11
4.1 General . 11
4.2 Laboratory and environmental conditions . 11
4.3 Supply voltage . 11
4.3.1 Supply voltage and frequency . 11
4.3.2 Supply voltage waveform . 11
4.4 Power measurement accuracy and uncertainty . 11
4.5 Network aspects . 12
4.5.1 General . 12
4.5.2 Wired networks . 12
4.5.3 Wireless networks: conducted connection for testing . 12
4.5.4 Wireless networks: radiated connection for testing. 13
5 Measurements . 15
5.1 General . 15
5.2 Equipment under test (EUT) . 15
5.2.1 General . 15
5.2.2 Illumination-only lighting equipment . 15
5.2.3 Multi-function lighting equipment . 19
5.3 Preparation of EUT . 20
5.3.1 General . 20
5.3.2 Measurement of input power . 20
5.3.3 EUT with no network provision . 22
5.3.4 EUT with network provision (wired or wireless) . 22
5.4 Measuring procedure . 22
5.4.1 General . 22
5.4.2 Direct meter reading method . 23
5.4.3 Average reading method . 23
5.4.4 Sampling method . 24
Annex A (informative) Guidance for product standards . 26
Annex B (normative) Measurement setup schemes for illumination-only lighting
equipment . 27
Annex C (normative) Measurement setup schemes for multi-function lighting
equipment . 30
........................................................................ 31
.......................................................................................................................... 33

Figure 1 – Test setup for non-active mode power consumption measurement of
conducted connected EUT . 13
Figure 2 – Test setup for non-active mode power consumption measurement of
connected EUT with integral antennas (RF path symbolically shown) . 14

IEC 63103:2020 © IEC 2020 – 3 –
Figure 3 – Calibration setup for non-active mode power measurement of connected
EUT with integral antennas . 14
Figure 4 – Components present within illumination-only EUT . 15
Figure 5 – Component representing an additional function (AF) of multi-function EUT . 19
Figure 6 – Configuration of multi-function lighting equipment: example including one
additional function . 19
Figure B.1 – Key to symbols used in figures of Annex B. 27
Figure B.2 – Measurement setup for determining the input power supplied to the power
supply . 27
Figure B.3 – Measurement setup (with optional network provision) for determining the
input power supplied to the control unit . 28
Figure B.4 – Measurement setup (with optional network provision) for determining the
input power supplied to the combined power supply and control unit . 28
Figure B.5 – Measurement setup for determining the input power supplied to the
combined light source and power supply . 28
Figure B.6 – Measurement setup (with optional network provision) for determining the
input power supplied to the combined light source and control unit . 28
Figure B.7 – Measurement setup (with optional network provision) for determining the
input power supplied to illumination-only lighting equipment . 29
Figure C.1 – Key to symbols used in figures of Annex C . 30
Figure C.2 – Measurement setup (with optional network provision) for determining the
input power to multi-function lighting equipment . 30
Figure D.1 – General measurement setup scheme for controlgear examples . 31
Figure D.2 – Networked standby mode measurement setup for the "basic" controlgear . 32
Figure D.3 – Networked standby mode measurement setup for controlgear with an
integrated auxiliary/bus power supply function . 32

Table 1 – Configurations and examples of illumination-only equipment and reference to
the measurement setup . 17
Table 2 – Template for reporting non-active mode power . 18
Table 3 – Example of using the template of Table 2 for reporting measured standby
power for an illumination-only luminaire with integrated presence sensor . 18
Table 4 – Example of using the template of Table 2 for reporting measured standby
power for a (multi-function) luminaire with an integrated presence sensor and an
integrated camera . 20

– 4 – IEC 63103:2020 © IEC 2020
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
LIGHTING EQUIPMENT –
NON-ACTIVE MODE POWER MEASUREMENT

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 63103 has been prepared by IEC technical committee 34: Lamps
and related equipment.
The text of this International Standard is based on the following documents:
FDIS Report on voting
34/698/FDIS 34/709/RVD
Full information on the voting for the approval of this International Standard can be found in
the report on voting indicated in the above table.
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.

IEC 63103:2020 © IEC 2020 – 5 –
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 6 – IEC 63103:2020 © IEC 2020
INTRODUCTION
The first edition of this document specifies uniform requirements for measuring non-active
mode power consumption for all lighting equipment. Present performance standards for
controlgear (IEC 62442 (all parts)) and luminaires (IEC 62722-1), already include some
descriptions for measuring standby power. It is expected that these standards will be
amended, accordingly.
In addition to an illumination function, today’s lighting equipment can execute a variety of
additional non-illumination functions, for example through integrated surveillance cameras,
noise detectors, occupancy counters, vehicular and pedestrian traffic detection, weather
detection, smoke detection, visible light communication and proximity or location devices.
During the execution of these functions, the (multi-function) lighting equipment can operate in
many different (active and non-active) modes. Non-active mode power consumption of (multi-
function) lighting equipment, i.e. the power consumed when the illumination function is off, is
an important aspect of lighting equipment and is becoming more important with the
emergence of connected lighting.
This document defines and describes methods of measurement of electrical power
consumption in non-active mode(s) for lighting equipment. The document is organized into
two main clauses: Clause 4 "General test conditions" and Clause 5 "Measurements".
Clause 4 contains specifications on the general conditions for making the measurements.
Subclauses 4.1 through 4.4 cover conditions for setting up the laboratory, selecting a supply
voltage and suitable instruments for the power measurement. Subclause 4.5 covers aspects
which should be considered when the lighting equipment is connected to a network to work
properly. Subclause 4.5.2 is for wired networks and 4.5.3 and 4.5.4 give setups for wireless
networks using conducted or radiated connections, respectively. These setups for wireless
networks are harmonized with ETSI Standard EN 300 328 and modified for lighting
equipment.
Clause 5 details the procedures for making measurements of the equipment under test (EUT).
Subclause 5.1 gives general instructions for setting the EUT into the possible non-active
mode(s). Subclause 5.2 details the large variety of EUTs. These EUTs can be placed into two
categories: illumination-only (5.2.2) and multi-function (5.2.3) lighting equipment. Traditional
lighting equipment with an illumination-only function is summarized in 5.2.2, Table 1. Multi-
function lighting equipment having additional non-illumination functions is addressed in 5.2.3.
A standardized form for reporting the measured result according to the functions and modes
of the multi-function lighting equipment under test is specified in 5.2.3, Table 2. Table 2 is a
central feature of this document that will enable all users to report their non-active power
results in a consistent manner.
Subclause 5.3 specifies procedures for preparing the EUT to make measurements of the input
power. Instructions for EUTs containing battery charging functions are found in 5.3.2.
Subclause 5.3.3 gives procedures for EUTs having no network provision and 5.3.4 covers
networked EUTs whether wired or wireless.
The measurement procedure is specified in 5.4 and offers three alternative methods and the
specific stability conditions required for each. These methods are adapted for lighting
equipment from IEC 62301:2011. The direct meter method specified in 5.4.2 has the most
limited applicability. It can only be used when the power reading is stable. In cases of
discrepancy, the average reading method (5.4.3) or sampling method (5.4.4) have
precedence. The average reading method is suitable only for EUTs having stable modes
whereas the sampling method is suited for cyclic or unstable modes and if the mode is of
limited duration.
IEC 63103:2020 © IEC 2020 – 7 –
Informative annexes are included to illustrate various measurement setups (Annex B and
Annex C) and Annex D provides practical examples of controlgear, for example involving
lighting equipment having a digital addressable lighting interface network in accordance with
IEC 62386 (all parts), and of luminaires.
The methods defined and described in this document are not intended to be used to measure
power consumption of (multi-function) lighting equipment during active mode(s) (also called
"on mode(s)"), as these are generally covered by IEC standards or other product standards.
This document provides methods of measurement for lighting equipment. However, the
methods specified in this document could also be used to measure lighting system models. A
system model is a full-size portion of the lighting system containing specific functions and can
set every mode of a portion of the system. The system models should be scalable to the
entire lighting system additively. Thus, the total non-active mode power consumption of the
system should equal the summation of power measured in each system model.
Using an adaptive roadway and pedestrian lighting system as an example for illustration, the
following three system models could be present:
– (A) five luminaires connected to one daylight sensor; illuminate to compensate daylight;
– (B) a luminaire with a pedestrian sensor, a daylight sensor, connected to a crosswalk
illumination; illuminate the crosswalk upon sensing a pedestrian when needed;
– (C) a dimmable luminaire with a vehicle detector; illuminate upon sensing a vehicle when
needed.
Assume the lighting system comprises 50 A-, 10 B-, and 20 C-system models, then the total
power consumption for a specified mode of the system would be
Power(mode) = 50 × power(A) + 10 × power(B) + 20 × power(C). Table 2 (5.2.3) could be
used to specify the measurement of a system model set in various combinations of modes. In
this way, the system is evaluated in measurable pieces (system models) set to function
interactively as the entire system is intended for each mode.

– 8 – IEC 63103:2020 © IEC 2020
LIGHTING EQUIPMENT –
NON-ACTIVE MODE POWER MEASUREMENT

1 Scope
This document specifies methods of measurement of electrical power consumption in non-
active mode(s), as applicable for electrical lighting equipment. This includes electrical lighting
equipment incorporating non-illumination components.
This document specifies neither performance requirements nor limits on power consumption.
This document applies to lighting equipment connected to a supply voltage up to 1 500 V DC
or up to 1 000 V AC.
This document is intended to be referenced by lighting equipment product standards for the
measurement of non-active mode power consumption. Details for the non-active mode power
consumption measurement and data presentation are specified in the product standards.
NOTE Annex A provides guidance on details specified in product standards.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their
content constitutes requirements of this document. For dated references, only the edition
cited applies. For undated references, the latest edition of the referenced document (including
any amendments) applies.
IEC 60050-845, International Electrotechnical Vocabulary – Part 845: Lighting (available at
http://www.electropedia.org)
IEC 62504, General lighting – Light emitting diode (LED) products and related equipment –
Terms and definitions
IEC TS 63105, Lighting systems and related equipment – Vocabulary
ETSI EN 300 328 V2.1.1 (2016-11), Wideband transmission systems; Data transmission
equipment operating in the 2,4 GHz ISM band and using wide band modulation techniques;
Harmonized Standard covering the essential requirements of article 3.2 of Directive
2014/53/EU
3 Terms and definitions
For the purposes of this document the terms and definitions given in IEC 60050-845,
IEC 62504 and IEC TS 63105 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
___________
Under preparation. Stage at the time of publication IEC CDTS 63105:2020.

IEC 63103:2020 © IEC 2020 – 9 –
3.1
lighting equipment
assembly of components used for the primary function of providing illumination, or any
component thereof
EXAMPLE Integrated lamp, non-integrated lamp plus controlgear, luminaire, controlgear, luminaire with camera.
Note 1 to entry: Lighting equipment can also include non-illumination components that offer non-illumination
functions.
Note 2 to entry: Within the primary function of illumination, applications like horticultural, UV disinfection, etc. are
included.
3.2
component
constituent part which cannot be physically divided into smaller parts without losing its
function
EXAMPLE Light source, power supply, control unit.
[SOURCE: IEC 60050-151:2001, 151-11-21, modified – "of a device" and "particular" deleted.]
3.3
supply voltage
SV
voltage applied by electric connection to provide electric energy
EXAMPLE 110 V AC, 230 V AC, 24 V DC, power over Ethernet.
[SOURCE: IEC 61347-1:2015, 3.5, modified – Definition adapted for lighting and examples
added.]
3.4
network
communication infrastructure with a topology of links, an architecture, including the physical
components, organizational principles, communication procedures and formats (protocols)
3.5
function
predetermined operating characteristic
EXAMPLE Illuminating, battery charging, wireless routing, auxiliary power output.
Note 1 to entry: Functions can be either on, off, in standby or networked standby.
Note 2 to entry: Typically, instructions for use specify which functions can be turned off and how.
3.6
mode
distinct configuration of the status of functions
3.7
active mode
mode with the illumination function on
3.8
non-active mode
mode with the illumination function off
EXAMPLE Standby mode, networked standby mode, off mode, no-load mode.

– 10 – IEC 63103:2020 © IEC 2020
3.9
off mode
mode with all functions off
Note 1 to entry: An indicator that only shows the user that the lighting equipment is in the off state is included
within the classification of off mode.
3.10
standby mode
mode when the equipment is connected to a supply voltage with the
illumination function off, while capable of being activated by an external trigger not being a
trigger from a network
Note 1 to entry: Examples of external triggers are sensing or timing.
3.11
networked standby mode
mode when the equipment is connected to a supply voltage with the
illumination function off, while capable of being activated by an external trigger being a trigger
from a network
3.12
no-load mode
mode when the equipment is connected to a supply voltage where the
illumination function is switched off or disconnected at the output circuit of the controlgear
3.13
charging maintenance mode
mode to maintain the battery in a fully charged condition
Note 1 to entry: Power consumption of emergency lighting equipment is called emergency lighting charging
power.
3.14
instructions for use
information that is provided by the manufacturer or responsible vendor for users of the
equipment
Note 1 to entry: Instructions for use would include a user manual and may be in paper or electronic form.
Instructions for use do not include any special directions provided by the equipment supplier to the test laboratory
especially for testing purposes.
[SOURCE: IEC 62301:2011, 3.12, modified – "by the manufacturer or responsible vendor"
added and "product" replaced with "equipment".]
3.15
equipment under test
EUT
equipment as specified in the scope of this document subjected to non-active mode power
consumption assessment
EXAMPLE Illumination-only lighting equipment or multi-function lighting equipment.
3.16
power boundary
perimeter surrounding the equipment under test through which all forms of energy flow and at
which the sum of power is measured

IEC 63103:2020 © IEC 2020 – 11 –
3.17
packet error rate
PER
ratio of the number of packets incorrectly received to the total number of packets sent
expressed as a percentage
4 General test conditions
4.1 General
Unless otherwise specified in relevant product standards or instructions for use,
measurements on the equipment under test (EUT) shall be made under the test conditions
and with measuring instruments specified in 4.2 to 4.5.
4.2 Laboratory and environmental conditions
The test shall be carried out at a room temperature of (25 ± 5) °C.
4.3 Supply voltage
4.3.1 Supply voltage and frequency
Tests shall be carried out at the rated voltage and at the rated frequency.
In the case where a rated voltage range is specified, tests shall be carried out at the minimum
and maximum value of that specified voltage range.
In case of alternative rated voltages, tests shall be performed separately for each rated
voltage.
In case of alternative rated AC frequencies or a rated frequency range, tests shall be
performed at the minimum and maximum frequency.
The supply voltage and the frequency shall be maintained constant within ±1 % during the
test.
4.3.2 Supply voltage waveform
In case of AC supply voltage, the total harmonic distortion (THD), up to and including the 13th
harmonic, of the supply voltage when supplying the EUT in the specified mode, shall not
exceed 3 %. THD is the ratio of the RMS value of the sum of the harmonic components (in
of orders 2 to at least 13) to the RMS value of
this context, harmonic current components I
h
the fundamental component, expressed as a percentage. The power supply shall not produce
inter-harmonics when operating in the power range of interest. In addition to the above, the
ratio of peak value to RMS value of the AC test voltage (i.e. crest factor) when supplying the
EUT shall be between 1,34 and 1,49.
In case of DC supply voltage, the ripple factor of the supply voltage shall be lower than 0,5 %.
4.4 Power measurement accuracy and uncertainty
For measurement accuracy, uncertainty and traceability see ISO/IEC Guide 98-3 and
IEC Guide 115.
– 12 – IEC 63103:2020 © IEC 2020
4.5 Network aspects
4.5.1 General
When the external trigger to change between active mode and non-active mode originates
from a network connection, care shall be taken to ensure that the network in question is
properly configured and connected to the EUT, to obtain an accurate measure of power
consumption. Where the use of additional products/components is needed for the
measurement of the EUT care shall be taken in the selection and characterization of these
items such that they are fully representative to the degree that the measurement accuracy for
the EUT is not adversely affected. The instructions for use shall contain information about
which functions can be turned off for the measurement and how to turn them off.
Care shall be taken as several power levels can be possible (e.g. power can be affected by
network connection quality, connection speed or the number and type of network
connections). The power consumption can also cycle in these modes.
For non-active mode power consumption measurements, the network functionality shall be
limited to setting the (non-active) mode of the EUT, such that no additional power
consumption is induced to the EUT beyond the need to set and maintain the non-active mode.
To test an EUT connected to a wired network, guidance is given in 4.5.2.
For a wireless network, there can be a difference in power consumption between the wireless
device looking for a connection (listening) and where the network connection is established. It
is important to consider that in a network, the energy consumption of the EUT can be affected
by its design, the environment and user interaction as well as network interaction.
When an EUT has the capability to connect to multiple wireless networks, non-active mode
power shall be determined for all networks independently.
An EUT connected to a wireless network can be configured either with an antenna connector
or an integrated antenna. In the case where the EUT has antenna connectors, the EUT can be
tested either by using a cabled connection (see 4.5.3) or by using the integrated antenna (for
direct radiating measurements, see 4.5.4).
NOTE In the case of a network receiver that is only waiting for trigger signal and where the power does not
change due to the quality of the network, there is no need to establish networks in accordance with 4.5.3 and 4.5.4.
4.5.2 Wired networks
Wired networks can induce power consumption by the EUT which is not linked to the intended
function to change modes of the lighting equipment. During measurements in non-active
mode, the EUT and a suitable controller shall be the only devices being connected to the bus.
Communication in such wired network shall be limited to what is needed to switch the EUT
from non-active mode to active mode within the time specified. During measurements, the
high voltage level of the communication bus (representing one logic state) shall be set to the
rated value with a tolerance of ±2 %. If a rated voltage range is specified, the middle value of
the range shall be set with a tolerance of ±2 %. The low voltage level of the bus shall be
negligibly low.
4.5.3 Wireless networks: conducted connection for testing
For an EUT whose ports are equipped with antenna connectors, testing shall be performed
using conducted measurements in accordance with the test setup shown in Figure 1 or in
accordance with 4.5.4.
IEC 63103:2020 © IEC 2020 – 13 –

Figure 1 – Test setup for non-active mode power consumption measurement
of conducted connected EUT
When this test method is selected, the following steps shall be employed to prepare the EUT
for measurement:
– For a frequency hopping EUT, operating channel variation is accepted as is.
– For a non-frequency hopping EUT, the EUT shall be set to an operating channel that will
be employed when the EUT is used for its intended application. The operating channel
frequency shall be recorded.
– A communication link is established between the EUT and the associated companion
device using the test setup shown in Figure 1. The attenuation of the variable attenuator
shall be increased in 1 dB steps to the maximum value at which the packet error rate
(PER) remains less than or equal to 10 %. The manufacturer may specify an alternative
PER if appropriate for the intended use of the EUT. The resultant signal level at the input
of the EUT is then P and shall be recorded.
min
– Set the wireless network command refreshment rate at 1 kHz, or at a relevant rate
provided by the manufacturer.
4.5.4 Wireless networks: radiated connection for testing
For an EUT with integral antennas, i.e. without antenna connectors, testing shall be
performed using radiated measurements in accordance with the test setup shown in Figure 2.
When this test method is selected, the following steps shall be employed to prepare the EUT
for measurement:
– A test site as described in Annex B of ETSI standard EN 300 328 V2.1.1 (2016-11) and
applicable measurement procedures as described in Annex C, Clauses C.1 to C.4
inclusive of the same standard shall be used.
– The test setup shall take the form shown in Figure 2.

– 14 – IEC 63103:2020 © IEC 2020

Figure 2 – Test setup for non-active mode power consumption measurement
of connected EUT with integral antennas (RF path symbolically shown)
– The transmitted power level from the associated companion device and its physical
separation from the EUT shall be adjusted until the packet error rate (PER) approaches
but remains less than or equal to 10 %. The manufacturer may specify an alternative PER
if appropriate for the intended use of the EUT.
– The resultant signal level at the input of the EUT is measured by a spectrum analyser
using a substitution antenna as shown in Figure 3. The measurement distance between
antennas and power setting of the signalling unit or companion device are kept fixed. The
absolute signal level, P , at the EUT shall be recorded as a calibration.
min
Figure 3 – Calibration setup for non-active mode power measurement
of connected EUT with integral antennas
– Following calibration, the substitution antenna and the spectrum analyser shall be
replaced with the EUT.
– Set the wireless network command refreshment rate at 1 kHz, or at a relevant rate
provided by the manufacturer.
IEC 63103:2020 © IEC 2020 – 15 –
5 Measurements
5.1 General
The purpose of the measurements is to determine the power consumption in persistent non-
active mode(s) of lighting equipment. A non-active mode is persistent when power
consumption is constant or when there are several power levels that occur in a regular
sequence.
NOTE 1 During transition from the active mode to the non-active mode some EUTs could be waiting in a higher
power state while transition tasks are performed, or circuits are energized or de-energized, so they can take some
time to enter a stable state.
NOTE 2 Where the EUT mode changes automatically it can sometimes be necessary to operate an EUT through
the automatic sequence several times on a trial basis to ensure that sequence is fully understood and documented
before test results are recorded and reported. A sequence of separate EUT modes can also exhibit a regular
ongoing pattern of power levels.
NOTE 3 While limited duration modes can be documented using measurements in accordance with this
document, the results for such modes can be reported as an energy consumption (Wh) and related time intervals.
A variety of non-active modes can be considered for assessing, for example:
– standby mode;
– networked standby mode;
– off mode;
– no-load mode.
The EUTs assessed are described in 5.2. To assess a specific mode, an EUT shall be
prepared as described in 5.3. Guidance for EUTs with battery charging provisions is also
given in 5.3.2. After preparation, power consumption of the EUT in the specified non-active
mode is determined via the procedure described in 5.4.
5.2 Equipment under test (EUT)
5.2.1 General
The EUT to be assessed on non-active mode power consumption can be lighting equipment
for illumination-only (for example lamps, luminaires and controlgear) and multi-function
lighting equipment (which include additional non-illumination function(s)). Details on
illumination-only lighting equipment is given in 5.2.2 and on multi-function lighting equipment
in 5.2.3.
5.2.2 Illumination-only lighting equipment
Illumination-only lighting equipment can consist of one or more components, which function as
light source (LS), power supply (PS) and control unit (CU). In Figure 4 these three
components are shown with their symbols used throughout this document.

a) Light source b) Power supply c) Control unit

Figure 4 – Components present within illumination-only EUT

– 16 – IEC 63103:2020 © IEC 2020
The light source (see Figure 4 a)) is the component responsible for generating light from the
energy delivered by the power supply.
NOTE For the purposes of this document, the light source is used to indicate a luminous element as defined in
IEC 60050-845:2020, 845-28-001.
The power supply (see Figure 4 b)) is the component converting, in a controlled way, power
from a supply voltage into power entering the light source for light generation.
The control unit (see Figure 4 c)) is the component acting as the interface between (external)
communication options and the EUT. The control unit is instrumental in changing the EUT
mode from active to non-active mode and vice versa, except when physica
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

The standard EN IEC 63103:2020 is pivotal in establishing a framework for the measurement of electrical power consumption in non-active modes of lighting equipment. Its primary focus is on detailing the methodologies necessary for quantifying non-active mode power, which is essential for understanding the energy efficiency of lighting products that incorporate components not directly related to illumination. One of the strengths of this standard is its comprehensive scope, which accommodates a wide range of electrical lighting equipment operating at supply voltages up to 1,500 V DC and 1,000 V AC. By covering various types of lighting products, EN IEC 63103:2020 ensures its relevance across diverse applications, thereby promoting standardized measurement practices within the industry. Furthermore, the standard addresses the nuances associated with non-active components, which are often overlooked in energy assessments. By explicitly outlining the methods for measuring non-active mode power consumption, this document fills a crucial gap, allowing manufacturers to accurately portray the energy profiles of their products. Another notable advantage of EN IEC 63103:2020 is its intended use as a reference point for other lighting equipment product standards. This integration facilitates consistency in measurement approaches across different standards, enhancing comparability and reliability in the assessment of power consumption. Moreover, the emphasis on data presentation ensures that the information derived from these measurements is clear and systematic, aiding users in making informed decisions based on standardized data. In summary, EN IEC 63103:2020 stands out due to its detailed methodology, broad applicability, and its role in promoting standardized practices regarding non-active mode power measurement in lighting equipment. The relevance and strength of this standard are instrumental in advancing energy efficiency initiatives within the lighting industry.

EN IEC 63103:2020は、照明機器における非アクティブモードの電力消費測定の方法を規定しています。この標準の範囲は、電気照明機器に関連する非照明コンポーネントを含むものであり、非常に広範で実用的です。 この文書の大きな強みは、非アクティブモードにおける電力消費の測定方法を明確にすることで、照明機器のエネルギー効率に関する基準を確立する点です。これにより、製品標準での非アクティブモード電力消費測定が容易になるため、業界全体での品質と一貫性が向上します。また、1,500 V DCまたは1,000 V ACまでの供給電圧に適用され、幅広い照明機器に関連する事例に対応しています。 この標準は、電力消費に関する性能要件や制限を明示しないため、メーカーが独自の設計や技術を追求できる自由度を提供します。特に非アクティブモードの電力消費測定を行うための詳細は、照明機器の製品標準に記載されているため、ユーザーにとっても使いやすい設計となっています。 EN IEC 63103:2020は、非アクティブモードに焦点を当てることで、市場におけるエネルギー消費の透明性を高め、消費者への信頼を構築する重要な役割を果たします。この文書が照明機器の製品標準によって参照されることで、業界内での一貫した測定基準が確立され、全体的な効率向上に寄与することが期待されます。

표준 SIST EN IEC 63103:2020은 비활성 모드 전력 측정에 대한 방법을 규정하고 있으며, 전기 조명 장비에 적용됩니다. 이 표준의 범위는 비조명 구성 요소를 포함한 전기 조명 장비의 비활성 모드 전력 소비 측정 방법을 상세히 설명하고 있습니다. 이 표준의 주요 강점 중 하나는 전기 조명 장비가 연결될 수 있는 전압 범위를 1,500V DC 또는 1,000V AC로 설정하여 넓은 적용 가능성을 제공한다는 점입니다. 또한, 성능 요구 사항이나 전력 소비 한도에 대한 규정을 두고 있지 않아, 다양한 조명 장비의 특성에 따라 유연하게 적용될 수 있습니다. SIST EN IEC 63103:2020은 비활성 모드 전력 소비 측정에 대한 구체적인 세부 사항을 제공하며, 이는 조명 장비 제품 표준들이 참조할 수 있도록 구성되어 있습니다. 이로 인해, 조명 제품의 전력 소비 데이터를 효과적으로 측정하고 제시할 수 있는 기반을 마련하고 있습니다. 전반적으로 이 표준은 조명 장비의 효율성을 평가하는 데 중요한 역할을 하며, 비활성 모드 전력 소비에 대한 명확하고 신뢰할 수 있는 측정 방법을 제시하고 있습니다.