Standard Safety Specification for Window Fall Prevention Devices for Non-Emergency Escape (Egress) and Rescue (Ingress) Windows

SCOPE
1.1 This safety specification establishes requirements for devices intended to address the risk of injury and death associated with accidental falls through open windows by children five years old and younger.
Note 1: This safety specification is not intended to meet the unique requirements of Americans With Disabilities Act (ADA).  
1.2 This safety specification applies only to window fall prevention devices, window fall prevention screens, and fall prevention window guards that are to be used on windows that are not intended for escape (egress) and rescue (ingress).
Note 2: Specification F2090 addresses window fall prevention devices (releasable), including window opening control devices (WOCD(s)) for windows intended for emergency escape and rescue and any other window not covered by this safety specification.  
1.3 This safety specification applies only to devices intended to be applied to windows installed at heights of more than 75 ft7 (23 m) above ground level in multiple family dwelling buildings. This safety specification is not intended to apply to windows below 75 ft (23 m) because all windows below 75 ft (23 m) that are operable and that meet the requirements for emergency escape and rescue openings could be used as a possible secondary means of escape.8
Note 3: Users of this safety specification should consult local authorities for other requirements that may apply to the use or installation, or both, of products covered by this safety specification.  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 This standard does not purport to address all safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and to determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
14-Jul-2021
Technical Committee
Current Stage
Ref Project

Buy Standard

Technical specification
ASTM F2006-21 - Standard Safety Specification for Window Fall Prevention Devices for Non-Emergency Escape (Egress) and Rescue (Ingress) Windows
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F2006-21 - Standard Safety Specification for Window Fall Prevention Devices for Non-Emergency Escape (Egress) and Rescue (Ingress) Windows
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: F2006 −21
Standard Safety Specification for
Window Fall Prevention Devices for Non-Emergency Escape
1,2
(Egress) and Rescue (Ingress) Windows
This standard is issued under the fixed designation F2006; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
INTRODUCTION
This consumer safety specification addresses window fall prevention devices that protect against
potential falls by children age five and under through open windows not designated for emergency
escapeorrescueininstallationsmorethan75ft(23m)abovegroundlevelinmultiplefamilydwelling
buildings since windows at these heights are beyond the reach of rescue ladders currently in use.
Window fall prevention devices currently available include Window Opening Control Devices
(WOCDs), window fall prevention screens, and some types of window guards. These devices use
different strategies to prevent children from falling through open windows. Window opening control
devices restrict the size of the open area of the window so that it is too small for a young child to fall
through. They do this by allowing the window opening to be set at a predetermined position. Window
fall prevention screens and fall prevention window guards provide a barrier to prevent a child from
falling through an open window. This safety specification is not intended for devices applied to
windows installed in one and two family dwellings.
3
A special study by the U.S. Consumer Product Safety Commission indicates that young children
are at high risk of death and serious injury from window falls. Children age five and younger account
4
for a higher percentage of window fall fatalities and injuries.
Security from forced entry is not within the scope of this safety specification and is not the intended
function of any of the devices referred to herein. Window fall prevention devices usually differ in
purpose and application from security/burglar bars. The general purpose of a window fall prevention
device is to prevent a child age five or younger from falling through an open window. The general
purpose of a security bar is to prevent unlawful entry through a window. Generally window fall
prevention devices and security bars are two separate devices. However, a security bar could be used
as a fall prevention device if it meets the requirements of this safety specification.
The CPSC has advised caregivers to open windows less than 4 in. when children are present as one
means to prevent child falls through open windows. The 4-in. dimension is drawn from related
5
building codes and standards for openings in guardrail assemblies, and is universally accepted as the
appropriate dimension to prevent a child from passing through balcony or guard railing systems.
Window opening control devices provide a means that the window, when opened in an initial
6
operation, will satisfy the CPSC recommendation to open less than 4 in.
Vent limiters are devices that restrict a sash from opening to a full open position. In instances where
the vent limiters restrict the sash to prevent the passage of a 4-in. (102-mm) diameter sphere, it may
be accepted as a means of complying with window fall prevention requirements in building codes.As
model building codes typically allow a less than 4-in. opening as an acceptable condition on
non-emergencyescapeandrescueopeningsandwithoutotherperformancerequirements,ventlimiters
are therefore outside of the scope of this safety specification.
Window Opening Control Devices (WOCDs) are not covered by this safety specification to avoid
confusion with devices under the scope of Specification F2006 for non-emergency escape and rescue
openings versus devices under the scope of Specification F2090 where the devices have release
mechanisms for emergency escape and rescue openings. WOCDs are a term to be used solely for
devices that comply with Specification F2090 in which the devices are releasable for sash operation
to allow escape and rescue from an emergency.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2006 − 21
1. Scope 1.6 This international standard was developed in accor-
dance with internationally recognized principles on standard-
1.1 This safety specification establishes requirements for
ization established in the Decision on Principles for the
devices intended to address the risk of inju
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F2006 − 17 F2006 − 21
Standard Safety Specification for
Window Fall Prevention Devices for Non-Emergency Escape
1,2
(Egress) and Rescue (Ingress) Windows
This standard is issued under the fixed designation F2006; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
INTRODUCTION
TheThis consumer safety specification addresses window fall prevention devices that protect
against potential falls by children age five and under through open windows not designated for
emergency escape or rescue in installations more than 75 ft (23 m) above ground level in multiple
family dwelling buildings since windows at these heights are beyond the reach of rescue ladders
currently in use. Window fall prevention devices currently available include Window Opening Control
Devices (WOCDs), window fall prevention screens, and some types of window guards. These devices
use different strategies to prevent children from falling through open windows. Window opening
control devices restrict the size of the open area of the window so that it is too small for a young child
to fall through. They do this by allowing the window opening to be set at a predetermined position.
Window fall prevention screens and fall prevention window guards provide a barrier to prevent a child
from falling through an open window. This safety specification is not intended for devices applied to
windows installed in one and two family dwellings.
3
A special study by the U.S. Consumer Product Safety Commission indicates that young children
are at high risk of death and serious injury from window falls. Children age five and younger account
4
for a higher percentage of window fall fatalities and injuries.
Security from forced entry is not within the scope of this safety specification and is not the intended
function of any of the devices referred to herein. Window fall prevention devices usually differ in
purpose and application from security/burglar bars. The general purpose of a window fall prevention
device is to prevent a child age five or younger from falling through an open window. The general
purpose of a security bar is to prevent unlawful entry through a window. Generally window fall
prevention devices and security bars are two separate devices. However, a security bar could be used
as a fall prevention device if it meets the requirements of this safety specification.
The CPSC has advised caregivers to open windows less than 4 in. when children are present as one
means to prevent child falls through open windows. The 4-in. dimension is drawn from related
5
building codes and standards for openings in guardrail assemblies, and is universally accepted as the
appropriate dimension to prevent a child from passing through balcony or guard railing systems.
Window opening control devices provide a means that the window, when opened in an initial
1
This safety specification is under the jurisdiction of ASTM Committee F15 on Consumer Products and is the direct responsibility of Subcommittee F15.38 on Window
Fall Prevention.
Current edition approved Nov. 1, 2017July 15, 2021. Published November 2017July 2021. Originally approved in 2000. Last previous edition approved in 20102017 as
F2006 – 10.F2006 – 17. DOI: 10.1520/F2006-17.10.1520/F2006-21.
2
This standard replaces former Provisional Safety Specification PS 112.
3
U.S. Consumer Product Safety Commission, special window falls study conducted in 1991.
4
U.S. Consumer Product Safety Commission, special window falls study conducted in 1991 and “Window Safety: Data and Patterns Related to Entrapments and
Accidental Falls from Windows,” prepared by AndersonAndersen Corporation.
Supporting data have been filed at ASTM International Headquarters and may be obtained by requesting Research Report RR:F15-1002. Contact ASTM Customer Service
at service@astm.org.
5
See NFPA 101, 2006 Edition Section 7.2.2.4.5.3. Also see Section 1015.8 Guard opening limitations in the 2015 1015.4 Opening limitations for guards in the 2018 and
2021 International Building Code (IBC).
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2006 − 21
6
operation, will satisfy the CPSC recommendation to open less than 4 in.
Vent limiters are devices
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.