Serija standardov SIST EN 54 Serija standardov SIST EN 50131
General Information
This document specifies the requirements for compatibility and connectability assessment of components of fire detection and fire alarm system or voice alarm system as a subsystem of fire detection and fire alarm system. The components comply either with the requirements of EN 54 or with a manufacturer’s specification where there is no EN 54 standard. This document only includes system requirements when these are necessary for compatibility assessment.
This document covers transmission path only between components. However ,requirements for TP between components of a function which is distributed are covered by the relevant EN 54 standard and not by this document.
This document also specifies requirements for the integrity of the fire detection and fire alarm system when connected to other systems.
This document does not specify the manner in which the system is designed, installed and used in any particular application.
This document recognizes that it is not practical to assess the compatibility or connectability of components in all possible configurations. Methods of assessment are specified to reach an acceptable degree of confidence within pre-determined operational and environmental conditions.
This document specifies requirements related to compatibility and connectability assessment methods and tests for the components belonging to FDAS or connecting FDAS. This document does not cover components or functions which are not included in a FDAS.
This document is applicable to systems where the components are interconnected by electrical wires or optical fibre or by radio frequency links or by any combination. For other interconnection technology between components , this standard may be used as a guidance.
NOTE Other European Standards are expected to cover the requirements of the other systems to which the fire detection and fire alarm system may be connected.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard includes requirements for warning devices used for notification in intrusion and hold up alarm systems installed in buildings. Four grades of warning device are described corresponding to each of the four security grades given in EN 50131-1. Requirements are also given for four environmental classes covering applications in indoor and outdoor locations as specified in EN 50130-5.
This European Standard does not deal with requirements for compliance with EC regulatory Directives, such as the EMC Directive, Low Voltage Directive, etc. except that it specifies the equipment operating conditions for EMC susceptibility testing as required by EN 50130-4.
- Standard36 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for Security Fog Devices connected to an I&HAS. It covers application and performance and also gives the necessary tests and trials to ensure efficiency and reliability of such obscuration devices.
This European Standard also gives guidance on the criteria for design, installation, operation and maintenance of Security Fog Devices.
A Security Fog Device is not considered to be a component of an I&HAS and no requirements are given relating to the security grade described in EN 50131-1.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, test methods and performance criteria for fire alarm sounders, including voice sounders, in a fixed installation intended to signal an audible warning between the fire detection and fire alarm systems and the occupants of a building (see EN 54-1:2011).
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of fire alarm sounders to this EN.
This European Standard is not intended to cover:
a) loudspeaker type devices primarily intended for emitting emergency voice messages that are generated from an external audio source;
b) supervisory sounders, for example, within the control and indicating equipment.
- Standard67 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard establishes the basis for testing and classifying free-standing safes, built-in safes (floor and wall), ATM safes and ATM bases, strongroom doors and strongrooms (with or without a door) according to their burglary resistance. This European Standard does not cover testing and classifying Deposit Systems and ATM systems.
- Standard54 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for high security locks (HSL) for reliability, resistance to burglary and unauthorized opening with methods of testing. It also provides a scheme for classifying HSL in accordance with their assessed resistance to burglary and unauthorized opening.
It applies to mechanical and electronic HSL. The following features may be included as optional subjects but they are not mandatory:
a) recognized code for preventing code altering and/or enabling/disabling parallel codes;
b) recognized code for disabling time set up;
c) integration of alarm components or functions;
d) remote control duties;
e) resistance to attacks with acids;
f) resistance to X-rays;
g) resistance to explosives;
h) time functions.
- Standard55 pagesEnglish languagesale 10% offe-Library read for1 day
This standard specifies the requirements for the performance, reliability and security characteristics of alarm transmission systems.
It covers the general requirements for connections providing signalling between an alarm system at a supervised premises and annunciation equipment at an alarm receiving centre.
EN 50136-1 Applies to transmission systems for all types of alarm messages such as fire, intrusion, access control, social alarm, etc. Different types of alarm system may in addition to alarm messages also send other types of messages, e.g. fault messages and status messages. These messages are also considered to be alarm messages. The term alarm is used in this broad sense throughout the document.
Additional requirements for the connection of specific types of alarm systems are given in the relevant European Standards.
- Amendment9 pagesEnglish languagesale 10% offe-Library read for1 day
This draft European Standard specifies requirements, test methods and performance criteria for point smoke detectors that operate using scattered light, transmitted light or ionization, intended for use in fire detection and fire alarm systems installed in and around buildings (see EN 54 1:2011).
This European standard provides for the assessment of verification of consistency of performance (AVCP) of point smoke detectors to this EN.
For other types of smoke detector, or smoke detectors working on different principles, this standard should only be used for guidance. Smoke detectors with special characteristics and developed for specific risks are not covered by this standard.
NOTE Certain types of detector contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not specified in this standard.
- Standard79 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard provides for security grades 1 to 4, (see EN 50131-1) specific or non-specific wired or wire-free lock state contacts, and includes the requirements for four environmental classes covering applications in internal and outdoor locations as specified in EN 50130-5.
Lock state contacts are installed in windows or doors and windows or doorframes to allow to monitor the lock/unlock status only or the lock/unlock status combined with the open/close status of a window/door simultaneously and are as such located in supervised premises. They provide the necessary range of signals or messages to be used by the rest of the intrusion alarm system.
A detector fulfils all the requirements of the specified grade.
Functions additional to the mandatory functions specified in this European Standard may be included in the detector, providing they do not influence the correct operation of the mandatory functions.
The combination of the two separate units of the lock state contact is referred to in the body of this European Standard as the detector.
This European Standard does not apply to system interconnections.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, test methods and performance criteria for point heat detectors intended for use in fire detection and fire alarm systems installed in and around buildings (see EN 54-1:2011).
This European Standard provides for the assessment of verification of constancy of performance (AVCP) of point heat detectors to this EN.
For other types of heat detector, or for detectors intended for use in other environments, this standard should only be used for guidance.
Heat detectors with special characteristics and developed for specific risks are not covered by this standard.
- Standard62 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements, performance criteria and testing procedures for PS to be used as part of Intrusion and Hold up Alarm Systems. The PS will either be an integral part of an I&HAS component or stand-alone. The control functions of the PS may be incorporated as part of the PS device, or may be provided by another I&HAS component, e.g. a CIE.
This European Standard is not applicable when the PS requirements for I&HAS components are included within the relevant product standard.
The requirements correspond to each of the four security grades given in the European Standard EN 50131-1, Alarm Systems – Intrusion and Hold-Up Systems – Part 1: System requirements. Requirements are also given for four environmental classes covering applications in indoor and outdoor locations.
This standard covers:
a) mandatory functions which will be provided on all PS, and
b) optional functions which may be provided.
This European Standard does not deal with requirements for compliance with EC regulatory Directives, such as the EMC Directive, Low Voltage Directive, etc. except that it specifies the equipment operating conditions for EMC susceptibility testing as required by EN 50130-4.
Other functions associated with I&HAS not specified in this standard may be provided. Such functions will not affect the requirements of any mandatory or optional functions.
- Standard52 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is for passive infrared detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European Standard does not include requirements for passive infrared detectors intended for use outdoors.
A detector shall fulfil all the requirements of the specified grade.
Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not influence the correct operation of the mandatory functions.
This European Standard does not apply to system interconnections.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
Harmonise system requirements with requirements for system components specified in standard published since EN 50131-1:2006 was published.
- Amendment14 pagesEnglish languagesale 10% offe-Library read for1 day
This International Standard specifies the requirements for establishing, implementing, maintaining
and continually improving an information security management system within the context of the
organization. This International Standard also includes requirements for the assessment and treatment
of information security risks tailored to the needs of the organization. The requirements set out in this
International Standard are generic and are intended to be applicable to all organizations, regardless
of type, size or nature. Excluding any of the requirements specified in Clauses 4 to 10 is not acceptable
when an organization claims conformity to this International Standard.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation31 pagesSlovenian languagesale 10% offe-Library read for1 day
This European Standard applies to intrusion alarm equipment using radio frequency (RF) links and located on protected premises. It does not cover long-range radio transmissions.
This European Standard defines the terms used in the field of intrusion alarm equipment using radio frequency links as well as the requirements relevant to the equipment.
- Standard20 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Specification is for ALDDR inside buildings and provides four security grades 1 to 4 (see EN 50131-1), specific or non-specific wire or wire-free ALDDR, and uses environmental classes I to IV (see EN 50130-5).
An ALDDR fulfils all the requirements of the specified grade.
The ALDDR detects an intruder inside a predefined area.
This standard covers ALDDR using both pulsed and continuous wave laser operation technologies according to LIDAR principle (Light Detection And Ranging). Other technologies i.e. doppler based laser operation or use of additional retro-reflective objects or video based technologies are not covered by this standard.
Functions additional to the mandatory functions specified in this standard may be included in the ALDDR, providing they do not adversely influence the correct operation of the mandatory functions.
This Technical Specification does not apply to system interconnections.
This Technical Specification does not deal with requirements for compliance with regulatory directives, such as EMC-directive, low-voltage directive, etc., except that it specifies the equipment operating conditions for EMC- susceptibility testing as required by EN 50130-4.
- Technical specification41 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is for shock detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows).
It provides for security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free detectors and uses Environmental Classes i-iv (see EN 50130-5).
This European Standard does not include requirements for detectors intended to protect for example vaults and safes from penetration attacks from e.g. drilling, cutting or thermal lance.
This European Standard does not include requirements for shock detectors intended for use outdoors.
A detector shall fulfill all the requirements of the specified grade.
Functions additional to the mandatory functions specified in this Technical Specification may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions.
This European Standard does not apply to system interconnections.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Specification provides recommendations for those methods of setting and unsetting an Intrusion Alarm System (IAS) complying with EN 50131-1 that will reduce unwanted alarms arising from “operator error” in setting and unsetting the IAS and provide confidence that the conditions in which the system is installed are conducive to system reliability during the “set” period.
This document details optional methods by which these goals may be achieved, either in isolation, or in conjunction with verification methods.
These recommendations should be incorporated into the respective standards in the EN 50131 series.
This Technical Specification also provides (in Annex A) recommendations for equipment and (in Annex C) associated test requirements, in order to permit the manufacture of standardized equipment to provide the functionality needed by an IAS to meet these recommendations.
NOTE This standard includes requirements that are additional to those in EN 50131-1 which are relevant when the respective method of setting and unsetting is implemented.
- Technical specification17 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Specification is applicable to Active Infrared Beam Detectors (AIBDs) installed inside buildings and used as part of intrusion alarm systems.
It specifies four security Grades 1 to 4 (in accordance with EN 50131 1) and uses environmental Classes I to IV (in accordance with EN 50130 5).
This standard covers only AIBDs using interruption based technology. Other technologies i.e. Doppler based technology are not covered by this document.
Functions additional to the mandatory functions specified in this document can be included in the AIBD, providing they do not adversely influence the correct operation of the mandatory functions.
This document does not apply to system interconnections.
- Technical specification36 pagesEnglish languagesale 10% offe-Library read for1 day
Change of the following chapters, to allow products to pass the relevant test section based on the relevant Annex : 6.6.3 Immunity to Hard objects hitting the glass & Annex A
- Amendment4 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is for passive surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV. This European Standard does not include requirements for passive surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This European Standard does not apply to system interconnections.
- Amendment4 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is for passive acoustic glass break detectors installed in buildings and provides for security Grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European Standard does not include requirements for passive acoustic glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This European Standard does not apply to system interconnections.
- Amendment4 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection and fire alarm systems installed in and around buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one carbon monoxide (CO) sensor and optionally one or more heat sensors, utilizing the combination of the detected phenomena. This European Standard covers only modes of operation, where at least the signals of both smoke and carbon monoxide sensors are continuously evaluated.
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of point detectors using a combination of smoke, carbon monoxide and optionally heat sensors to this EN.
Point detectors using a combination of smoke, carbon monoxide and optionally heat sensors, which are having special characteristics suitable for the detection of specific fire risks are not covered by this European Standard. The performance requirements for any additional functions are beyond the scope of this standard (e.g. additional features or enhanced functionality for which this European Standard does not define a test or assessment method).
- Standard107 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to non-resettable line-type heat detectors consisting of a sensing element using an electrical sensor cable which can be connected to a sensor control unit or either directly or through an interface module to a control and indicating equipment intended for use in fire detection and fire alarm systems installed in and around buildings and civil engineering works (see EN 54 1:2011).
The non-resettable sensing element has a fixed temperature alarm threshold and does not distinguish between short circuit and alarm condition.
This European Standard specifies the requirements and performance criteria, the corresponding test methods and provides for the Assessment and Verification of Constancy of Performance (AVCP) of non-resettable line-type heat detectors to this European Standard.
This European Standard also covers non-resettable line-type heat detectors intended for use in the local protection of plant and equipment.
Non-resettable line-type heat detectors with special characteristics and developed for specific risks are not covered by this standard.
- Standard66 pagesEnglish languagesale 10% offe-Library read for1 day
Corrigendum to add: EN 60839-11-2 supersedes EN 50133-7:1999
- Corrigendum1 pageEnglish languagesale 10% offe-Library read for1 day
This International Standard specifies the requirements for an environmental management system
that an organization can use to enhance its environmental performance. This International Standard
is intended for use by an organization seeking to manage its environmental responsibilities in a
systematic manner that contributes to the environmental pillar of sustainability.
This International Standard helps an organization achieve the intended outcomes of its environmental
management system, which provide value for the environment, the organization itself and interested
parties. Consistent with the organization’s environmental policy, the intended outcomes of an
environmental management system include:
— enhancement of environmental performance;
— fulfilment of compliance obligations;
— achievement of environmental objectives.
This International Standard is applicable to any organization, regardless of size, type and nature,
and applies to the environmental aspects of its activities, products and services that the organization
determines it can either control or influence considering a life cycle perspective. This International
Standard does not state specific environmental performance criteria.
This International Standard can be used in whole or in part to systematically improve environmental
management. Claims of conformity to this International Standard, however, are not acceptable unless
all its requirements are incorporated into an organization’s environmental management system and
fulfilled without exclusion.
- Standard46 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard49 pagesGerman languagesale 10% offe-Library read for1 day
- Standard – translation66 pagesSlovenian and English languagesale 10% offe-Library read for1 day
ISO 9001:2015 specifies requirements for a quality management system when an organization:
a) needs to demonstrate its ability to consistently provide products and services that meet customer and applicable statutory and regulatory requirements, and
b) aims to enhance customer satisfaction through the effective application of the system, including processes for improvement of the system and the assurance of conformity to customer and applicable statutory and regulatory requirements.
All the requirements of ISO 9001:2015 are generic and are intended to be applicable to any organization, regardless of its type or size, or the products and services it provides.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation55 pagesSlovenian and English languagesale 10% offe-Library read for1 day
This part of IEC 60839 defines the minimum requirements and guidance for the installation
and operation of electronic access control systems (EACS) and/or accessory equipment to
meet different levels of protection.
This standard includes requirements for planning, installation, commissioning, maintenance
and documentation for the application of EACS installed in and around buildings and areas.
The equipment functions are defined in the IEC 60839-11-1.
When the EACS includes functions relating to hold-up or the detection of intruders, the
requirements in standards relating to intrusion and hold-up are also applicable.
This standard provides application guidelines intended to assist those responsible for
establishing an EACS to ascertain the appropriate design and planning of the EACS, both in
terms of levels of protection and levels of performance necessary to provide the degree of
access control and protection considered appropriate for each installation. This is achieved by
scaling or classifying the features of electronic access control systems related to the security
functionality (e.g. recognition, access point actuation, access point monitoring, duress
signaling and system self-protection) in line with the known or perceived threat conditions.
This standard does not cover the methods and procedures for conducting a risk assessment.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection systems installed in buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one heat sensor. The overall fire detection performance is determined utilizing the combination of the detected phenomena.
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of point detectors using a combination of smoke and heat sensors to this EN.
Point detectors using a combination of smoke and heat sensors having special characteristics suitable for the detection of specific fire risks are not covered by this European Standard. The performance requirements for any additional functions are beyond the scope of this European Standard (e.g. additional features or enhanced functionality for which this European Standard does not define a test or assessment method).
NOTE Certain types of detector contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not specified in this European Standard.
- Standard96 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements, test methods and performance criteria for line detectors using an optical beam that detect smoke by utilizing the attenuation and/or changes in attenuation of an optical beam, for use in fire detection and fire alarm systems installed in buildings (see EN 54 1:2011).
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of line detectors using an optical beam to this EN.
This European Standard does not cover:
- Line detectors using an optical beam designed to operate with separations between opposed components of less than 1 m;
- Line detectors using an optical beam whose optical path length is defined or adjusted by an integral mechanical connection;
- Line detectors using an optical beam with special characteristics, which cannot be assessed by the test methods in this European Standard.
NOTE The term “optical” is used to describe that part of the electromagnetic spectrum produced by the transmitter to which the receiver is responsive; this is not restricted to visible wavelengths.
- Standard71 pagesEnglish languagesale 10% offe-Library read for1 day
- Corrigendum1 pageEnglish languagesale 10% offe-Library read for1 day
This Technical Specification is for shock detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows).
It provides for security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free detectors and uses Environmental Classes i-iv (see EN 50130-5).
This Technical Specification does not include requirements for detectors intended to protect for example vaults and safes from penetration attacks from e.g. drilling, cutting or thermal lance.
This Technical Specification does not include requirements for shock detectors intended for use outdoors.
A detector shall fulfil all the requirements of the specified grade.
Functions additional to the mandatory functions specified in this Technical Specification may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions.
This Technical Specification does not apply to system interconnections.
- Addendum6 pagesEnglish languagesale 10% offe-Library read for1 day
CLC/TS 50131-9 is available for use where alarm verification methods are considered necessary. It provides recommendations for the addition and use of alarm verification technology in Intrusion and Hold-up Alarm Systems (I&HAS) installed to comply with EN 50131-1. These recommendations should be incorporated into the respective standards in the EN 5013x series. This Technical Specification does not detail methods of alarm verification relying solely on Alarm Receiving Centre (ARC) procedures, but does not preclude their use. This Technical Specification describes alarm verification methods that could be applied and details applicable to system and equipment design. The framework limits the range of options in order to provide for local regulations and circumstances, whilst permitting a standardised approach to equipment design. This Technical Specification also provides (in Annex A) recommendations for equipment in order to permit the manufacture of standardised equipment to provide the functionality needed by an I&HAS incorporating alarm verification technology. The associated guidelines for use in ARCs to monitor notification from such I&HAS can be found in EN 50518-3.
- Technical specification28 pagesEnglish languagesale 10% offe-Library read for1 day
EN 50131-10 specifies requirements for SPT used in I&HAS to transmit alarm and other messages to a location remote from the supervised premises. This European Standard gives specific requirements for SPT used in Intrusion and Hold-up Alarm Systems (I&HAS) and should be used in combination with EN 50136-2. The requirements of this European Standard apply to different types of SPT including separate SPT, SPT located within the housings of other I&HAS components and also when the SPT functionality is integrated with the CIE or other parts of an I&HAS.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
EN 1143-2 specifies requirements and tests methods for deposit systems, and classifies the systems according to their burglary resistance and their resistance to the theft of deposits. This European Standard comprises two types of deposit system: - night safes which provide depositing services for the customers of financial institutions without giving access to the content of the night safe. - deposit safes which enable the personnel of a company to place money or valuables in safe custody without giving access to the content of the deposit safe. The installation condition for deposit safe according to this standard is that the depositing functions are installed inside the premises of the company and are only disposable for the personnel of the company. Parts of a Deposit system are a receiving unit, an input unit and in some cases, a chute. The standard includes design requirements for deposit systems controlled by programmable controllers and for the software for these. Controller hardware testing is restricted to mechanical or electromechanical attacks of electric motors, sensors, coils and similar devices; but software testing as attempts to influence controller software or controller hardware is not part of this standard. Deposit systems may have devices for functions such as user identification and/or counting and registration of money. Tests of and requirements for classification of such functions are not included. This standard does not cover protection of persons using the deposit system or the prevention of fraud committed by operators of the deposit system.
- Standard50 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the minimum equipment requirements for the performance, reliability, resilience, security and safety characteristics of the receiving centre transceiver (RCT) installed in ARC and used in alarm transmission systems.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard provides for security grades 1 to 4, (see EN 50131-1) specific or non-specific wired or wire-free opening contacts (magnetic), and includes the requirements for four environmental classes covering applications in internal and outdoor locations as specified in EN 50130-5. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this European Standard may be included in the detector, providing they do not influence the correct operation of the mandatory functions. The two separate parts of the opening contact (magnetic) shall be referred to in the body of this European Standard as the detector. This European Standard does not apply to system interconnections.
- Addendum6 pagesEnglish languagesale 10% offe-Library read for1 day
This standard is for combined passive infrared and microwave detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This standard does not include requirements for detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not influence the correct operation of the mandatory functions. The standard does not apply to system interconnections.
- Addendum6 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is for passive acoustic glass break detectors installed in buildings and provides for security Grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European Standard does not include requirements for passive acoustic glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This European Standard does not apply to system interconnections.
- Addendum6 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Specification is for dedicated hold-up devices in buildings, e.g. deliberately operated hold-up devices which can be triggered to create a hold-up alarm signal or message. It provides four security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free hold-up devices and uses Environmental Classes I-IV (see EN 50130-5). This Technical Specification does not include requirements for hold-up devices intended for use outdoors, or for mobile hold-up devices or for devices with functions additional to hold-up facility. NOTE If a device provides functions additional to hold-up facility, it is recommended to function similar to the requirement described in this Technical Specification. Functions additional to the mandatory functions as specified in this Technical Specification may be included in the hold-up device, providing they do not adversely influence the correct operation of the mandatory functions. This Technical Specification does not apply to system interconnections.
- Addendum6 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is for microwave detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This standard does not include requirements for microwave detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not influence the correct operation of the mandatory functions. The standard does not apply to system interconnections.
- Addendum6 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is for active surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV. This European Standard does not include requirements for active surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This European Standard does not apply to system interconnections.
- Addendum6 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is for passive surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV. This European Standard does not include requirements for passive surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This European Standard does not apply to system interconnections.
- Addendum6 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is for combined passive infrared and ultrasonic detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This standard does not include requirements for combined passive infra red and ultrasonic detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not influence the correct operation of the mandatory functions. The European Standard does not apply to system interconnections.
- Addendum6 pagesEnglish languagesale 10% offe-Library read for1 day
CLC/TS 50131-2-10 provides for security grades 1 to 4, (see EN 50131-1) specific or non-specific wired or wire-free lock state contacts, and includes the requirements for four environmental classes covering applications in internal and outdoor locations as specified in EN 50130-5. The purpose of a lock state contact (magnetic) is to detect the lock/unlock state only or the lock/unlock state combined with the opening status/displacement from the defined closed position of a window or door simultaneously. The lock state contact comprises two separate contact-less units, the active connection between these units is at least one magnetic or electromagnetic based field. Separating the two units disturbs the connection and produces an intruder signal or message. A detector will fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this Technical Specification may be included in the detector, providing they do not influence the correct operation of the mandatory functions. The combination of the two separate units of the lock state contact is referred to in the body of this Technical Specification as the detector. This Technical Specification does not apply to system interconnections.
- Technical specification32 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is for active surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV. This European Standard does not include requirements for active surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This European Standard does not apply to system interconnections.
- Amendment6 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is for passive acoustic glass break detectors installed in buildings and provides for security Grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European Standard does not include requirements for passive acoustic glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This European Standard does not apply to system interconnections.
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the general equipment requirements for the performance, reliability, resilience, security and safety characteristics of supervised premises transceiver (SPT) installed in supervised premises and used in alarm transmission systems (ATS). A supervised premises transceiver can be a stand-alone device or an integrated part of an alarm system. These requirements also apply to SPT’s sharing means of interconnection, control, communication and power supplies with other applications. The alarm transmission system requirements and classifications are defined within EN 50136-1. Different types of alarm systems may in addition to alarm messages also send other types of messages, e.g. fault messages and status messages. The term alarm is used in this broad sense throughout the document. Additional requirements for the connection of specific types of alarm systems are given in the relevant European Standards. Because the SPT can be applied in different applications (e.g. I&HAS, fire and social alarm systems), requirements for the SPT, additional to those of this European Standard, may be specified in separate application specific documents. This European Standard specifies the requirements specific to alarm transmission. Application specific requirements for the connection of the SPT to specific types of alarm systems are given in the EN 50131 (all parts) for I&HAS, and EN 54 (all parts) for fire. For other SPT applications, see the relevant National or European standards.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This part of IEC 60839 specifies the minimum functionality, performance requirements and test methods for electronic access control systems and components used for physical access (entry and exit) in and around buildings and protected areas. It does not include requirements for access point actuators and sensors. This standard is not intended to cover requirements for off premise transmission associated with intrusion or hold up alarm signals. This standard applies to electronic access control systems and components intended to be used in security applications for the granting of access and includes requirements for logging, identification and control of information. The standard comprises the following:
- A conceptual model and system architecture.
- Criteria covering: - classification based on performance functionalities and capabilities; - access point interface requirements; - indication and annunciation requirements (display, alert, logging); - duress signalling and overriding; - recognition requirements; - system self-protection requirements; - communication between the component parts of the electronic access control system and with other systems.
- Requirements for environmental conditions (indoor/outdoor use) and electromagnetic compatibility.
- Test methods.
- Standard61 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Specification details methods and tests for compatibility assessment of system components, including a CIE, intended to be used in intruder and hold up alarm systems complying with EN 50131-1. This includes: - I&HAS components for which EN 50131 series product standards exist; - I&HAS components for which no EN 50131 series product standards currently exist; - I&HAS components that include additional functionality outside the scope of EN 50131-1 or shared with another system; - non-I&HAS components used to supplement the functionality of the system, but which are not required by EN 50131-1 (e.g. printer). The assessment and testing covered by this Technical Specification focuses on verifying the functionality of each event type from source to destination between components. It is not intended to repeat specific tests contained within the relevant product standard, but does include the verification that there are no adverse affects on mandatory EN 50131 functions as a result of the intended use of the components. This Technical Specification does not detail the manner in which an I&HAS is designed, installed and used in any particular application. This Technical Specification recognizes that it is not practical to assess the compatibility of components in all possible configurations and conditions. Methods of assessment are specified to reach an acceptable degree of confidence within pre-determined configurations and conditions. This Technical Specification is applicable to components connected to CIE whether the components are interconnected by electrical wires, wire-free links or other means. The test programme developed to assess compatibility may be undertaken as part of a programme to assess the performance of a component according to a part of EN 50131.
- Technical specification14 pagesEnglish languagesale 10% offe-Library read for1 day