PPV - Secure storage units and door locks
Standardization in the field of the performance of physical security products providing protection against burglary and/or fire.
Protivlomni in protipožarni vsebniki in zaklepni mehanizmi
Standardizacija tehničnih sredstev, ki zagotavljajo varovanje pred vlomom oziroma požarom.
General Information
This part of this European Standard specifies requirements for fire resisting data cabinets and diskette inserts.
Two methods of test are specified to determine the ability of fire resisting data cabinets to protect temperature and humidity sensitive contents from the effects of fire: a fire endurance test and a fire shock and impact test. Two levels of fire severity (S 60 and S 120) based upon time of fire exposure; and three protection classes (P, D and DIS) are specified using the maximum temperature increases and humidity values permitted within the storage space of the data cabinet.
Diskette inserts (DI 60 P/DIS and DI 120 P/DIS) are installed in data cabinets of protection class S 60 P or S 120 P, respectively, and subjected to a fire endurance test (see 5.1.2).
Requirements are also specified for test specimens, the technical documentation for the test specimen, correlation of the test specimen with the technical documentation, preparation for type testing and test procedures.
A scheme to classify the fire resisting data cabinets and diskette inserts from the test results is also given (see Table 1).
Diskette inserts should only be installed in data cabinets having the same design as the series of protection class S 60 P and S 120 P, respectively, in which the insert has been tested in accordance with 5.1.2. Where several inserts are installed, they should be built in one beside the other or one above the other from bottom to top, respectively. The volume and total height of the installed inserts should not exceed 50 % of the total internal volume or 50 % of the internal height, respectively, of the data cabinets into which they are installed. The dimensions of the insert can be adapted by increasing the width and depth to the corresponding dimensions of the data cabinets. A reduction of these dimensions as well as a change of the height is only admitted within the specified tolerance.
The temperature increases during type-tests on data cabinets and diskette inserts will be considered in deciding the permitted diskette insert installations. For a permitted installation, the temperature increase of the intended data cabinet (∆T_A∙K) should not exceed the temperature increase of the tested data cabinet (∆T_B∙K) in which the diskette insert has been type-tested by more than the difference between the maximum value for the diskette insert (∆T_i∙K) and the maximum admissible temperature increase (30 K), i.e ∆T_A- ∆T_B≤30 K- ∆T_i (See example in Annex B).
A description of the installation of the diskette inserts should be given in the technical documentation of the manufacturer.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for light fire storage units providing protection against fire.
The method of test is specified to determine the ability of light fire storage units to protect paper media from the effects of fire. Two levels of fire exposure periods (LFS 30 P and LFS 60 P) are specified using the maximum temperature increase permitted within the storage space of the light fire storage unit.
Requirements are also specified for the test specimen, the technical documentation for the test specimen, correlation of the test specimen with the technical documentation, preparation for type testing and test procedures.
A scheme to classify the light fire storage units from the test results is also given (see Table 1).
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This part of the European Standard EN 1047 specifies requirements for data rooms and data containers. It includes a method of test for the determination of the ability of data rooms and data containers to protect temperature and humidity sensitive data media (see 3.5) and hardware systems (see 3.6) from the effects of fire. A test method for measuring the resistance to mechanical stress (impact test) provided by data rooms type B and data containers is also specified.
Requirements are also specified for test specimens, the technical documentation of the test specimens, materials specimens, physical fittings, the correlation of test specimens with the technical documentation and the preparation for type testing, as test procedures as well as the series production.
In addition, a scheme to classify data rooms and data containers from the test results is given (see Table 1).
As well as providing protection against fire, correctly installed data rooms and data containers offer a defined protection against impacts caused by failure during fire of components and objects external to the data room or data container.
Data rooms and data containers having the same design, protection and construction features (type and thickness of construction and protective materials, rebate geometry, lockings, doors, etc.) will only be given the same protection classification as that of the test specimen if the tolerances are within the ranges specified in Clause 7.
NOTE This European Standard does not regulate the use of data rooms in the meaning of the building laws of the respective countries. In the construction of data rooms, the respective national requirements should be considered.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard establishes the basis for testing and classifying free-standing safes, built-in safes (floor and wall), ATM safes and ATM bases, strongroom doors and strongrooms (with or without a door) according to their burglary resistance. This European Standard does not cover testing and classifying Deposit Systems and ATM systems.
- Standard54 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for high security locks (HSL) for reliability, resistance to burglary and unauthorized opening with methods of testing. It also provides a scheme for classifying HSL in accordance with their assessed resistance to burglary and unauthorized opening.
It applies to mechanical and electronic HSL. The following features may be included as optional subjects but they are not mandatory:
a) recognized code for preventing code altering and/or enabling/disabling parallel codes;
b) recognized code for disabling time set up;
c) integration of alarm components or functions;
d) remote control duties;
e) resistance to attacks with acids;
f) resistance to X-rays;
g) resistance to explosives;
h) time functions.
- Standard55 pagesEnglish languagesale 10% offe-Library read for1 day
This document establishes the basis for testing and classifying secure safe cabinets.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
EN 1143-2 specifies requirements and tests methods for deposit systems, and classifies the systems according to their burglary resistance and their resistance to the theft of deposits. This European Standard comprises two types of deposit system: - night safes which provide depositing services for the customers of financial institutions without giving access to the content of the night safe. - deposit safes which enable the personnel of a company to place money or valuables in safe custody without giving access to the content of the deposit safe. The installation condition for deposit safe according to this standard is that the depositing functions are installed inside the premises of the company and are only disposable for the personnel of the company. Parts of a Deposit system are a receiving unit, an input unit and in some cases, a chute. The standard includes design requirements for deposit systems controlled by programmable controllers and for the software for these. Controller hardware testing is restricted to mechanical or electromechanical attacks of electric motors, sensors, coils and similar devices; but software testing as attempts to influence controller software or controller hardware is not part of this standard. Deposit systems may have devices for functions such as user identification and/or counting and registration of money. Tests of and requirements for classification of such functions are not included. This standard does not cover protection of persons using the deposit system or the prevention of fraud committed by operators of the deposit system.
- Standard50 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard6 pagesSlovenian languagesale 10% offe-Library read for1 day
This European Standard gives recommendations for the management and control of confidential material destruction, to ensure that such material is disposed of securely and safely. The recommendations apply to a company's main business premises and any holding sites.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements and testing procedures for high security locks used in distributed systems, which are mainly used in secure storage units. A distributed system, as per the definition of this European Standard, is a system with components connected by a transmission system, wired or wireless. Also, a token represents a distributed system as of a transmission distance of 15 cm or more.
The present standard responded to the state of the art requirements for distributed systems when it was written down.
However it is mandatory that the standard has to be revised with a relatively high frequency of 3 years or less, as the research in the area of cryptography and relevant attacks evolve with high speed as well as the referenced standards. As the general regulations of EN 1300 don’t require such a high frequency of updating, it is recommended to separate the standards.
- Draft27 pagesEnglish languagesale 10% offe-Library read for1 day
Data rooms and data containers are fire protection security products whose purpose is to protect temperature and humidity sensitive data media and hardware systems from the effects of fire. These fire resistance products do not provide any defined protection against burglary.
Based on these objectives, the CEN/TC 263 Working Group WG2 Fire Resistance unanimously noted at its meeting on 8 March 2012 that the requirement for a certified high security lock according to EN 1300 for data rooms and data containers suggests protection that is not provided and does not reflect the requirements of the market.
For the reasons explained above, WG2 unanimously recommended deletion of the requirements for a certified high security lock according to EN 1300 without replacement from EN 1047-2:2009. In the interest of the market, this change in this European Standard shall be implemented very soon via an Amendment to EN 1047-2:2009. The necessary decision shall be taken in a 3 months shortened UAP. The necessary application shall be filed with the CEN/TC 263 via DIN.
The draft for Amendment A1 to EN 1047-2:2009 shall be presented to the CEN/TC 263 together with the application for changes in this European Standard.
- Amendment5 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for light fire storage units providing protection against fire. The method of test is specified to determine the ability of light fire storage units to protect paper media from the effects of fire. Two levels of fire exposure periods (LFS 30 P and LFS 60 P) are specified using the maximum temperature increase permitted within the storage space of the light fire storage unit. Requirements are also specified for the test specimen, the technical documentation for the test specimen, correlation of the test specimen with the technical documentation, preparation for type testing and test procedures. A scheme to classify the light fire storage units from the test results is also given (see Table 1).
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
This part of this European Standard specifies requirements for fire resisting data cabinets and diskette inserts. Two methods of test are specified to determine the ability of fire resisting data cabinets to protect temperature and humidity sensitive contents from the effects of fire: a fire endurance test and a fire shock and impact test. Two levels of fire severity (S 60 and S 120) based upon time of fire exposure; and three protection classes (P, D and DIS) are specified using the maximum temperature increases and humidity values permitted within the storage Diskette inserts (DI 60 P/DIS and DI 120 P/DIS) are installed in data cabinets of protection class S 60 P or S 120 P, Requirements are also specified for test specimens, the technical documentation for the test specimen, correlation of the test specimen with the technical documentation, preparation for type testing and test procedures. A scheme to classify the fire resisting data cabinets and diskette inserts from the test results is also given (see Cabinets having the same design, protection and construction features (type and thickness of construction and protective materials, rebate geometry, locking, etc.) will only give the same fire protection classification as that of a test specimen if they are of similar internal dimensions. The maximum difference in internal dimensions (height, width and depth of the storage space, measured from wall to wall) to which the test classification could apply is + 15 %. Cabinets having internal dimensions which differ by more than this amount from that of the tested specimen The wall, ceiling and door thicknesses should not be below the specified minimum limit of the type-tested thickness Diskette inserts should only be installed in data cabinets having the same design as the series of protection class S 60 P and S 120 P, respectively, in which the insert has been tested in accordance with 5.1.2. Where several inserts are installed, they should be built in one beside the other or one above the other from bottom to top, respectively. The volume and total height of the installed inserts should not exceed 50 % of the total internal volume or 50 % of the internal height, respectively, of the data cabinets into which they are installed. The dimensions of the insert can be adapted by increasing the width and depth to the corresponding dimensions of the data cabinets. A reduction of these dimensions as well as a change of the height is only admitted within the specified tolerance. The temperature increases during type-tests on data cabinets and diskette inserts will be considered in deciding the permitted diskette insert installations. For a permitted installation, the temperature increase of the intended data cabinet (.Ta K) should not exceed the temperature increase of the tested data cabinet (.Tb K) in which the diskette insert has been type-tested by more than the difference between the maximum value for the diskette insert (.Ti K) and the maximum admissible temperature increase (30 K), i.e: .Ta;.Tb =30 K;.Ti (See example in annex B).A description of the installation of the diskette inserts should be given in the technical documentation of the manufacturer.
- Standard23 pagesEnglish languagesale 10% offe-Library read for1 day
This part of the European Standard EN 1047 specifies requirements for data rooms and data containers. It includes a method of test for the determination of the ability of data rooms and data containers to protect temperature and humidity sensitive data media (see 3.5) and hardware systems (see 3.6) from the effects of fire. A test method for measuring the resistance to mechanical stress (impact test) provided by data rooms type B and data containers is also specified. Requirements are also specified for test specimens, the technical documentation of the test specimens, materials specimens, physical fittings, the correlation of test specimens with the technical documentation and the preparation for type testing as well as test procedures. In addition, a scheme to classify data rooms and data containers from the test results is given (see Table 2). As well as providing protection against fire, correctly installed data rooms and data containers offer protection against impacts caused by failure during fire of components and objects external to the data room or data container.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard establishes the basis for testing and classifying free-standing safes, built-in safes (floor and wall), ATM safes and ATM bases, strongroom doors and strongrooms (with or without a door) according to their burglary resistance. This European Standard does not cover testing and classifying Deposit Systems and ATM systems.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for high security locks (HSL) for reliability, resistance to burglary and unauthorized opening with methods of testing. It also provides a scheme for classifying HSL in accordance with their assessed resistance to burglary and unauthorized opening. It applies to mechanical and electronic HSL. The following features may be included as optional subjects but they are not mandatory: a) recognized code for preventing code altering and/or enabling/disabling parallel codes; b) recognized code for disabling time set up; c) integration of alarm components or functions; d) remote control duties; e) resistance to attacks with acids; f) resistance to X-rays; g) resistance to explosives; h) time functions.
- Standard46 pagesEnglish languagesale 10% offe-Library read for1 day
This document establishes the basis for testing and classifying secure safe cabinets.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements and tests for deposit systems, and classifies the systems according to their burglary resistance and their resistance to the theft of deposits.
The standard includes design requirements for deposit systems controlled by programmable controllers. In this European Standard, controller hardware testing is restricted to electric motors, sensors, coils and similar devices; software testing is not part of this standard.
Deposit systems may have devices for functions such as user identification and/or counting and registration of money. Tests and classification of such functions are not included in this European Standard.
This European Standard does not cover protection of persons using the deposit system or the prevention of fraud committed by operators of the system.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for high security locks (HSL) for reliability, resistance to burglary and unauthorized opening with methods of testing. It also provides a scheme for classifying HSL in accordance with their assessed resistance to burglary and unauthorised opening.
It applies to mechanical and electronic HSL. The following features may be included as optional subjects but they are not mandatory:
1) recognised code for preventing code altering and/or enabling/disabling parallel codes;
2) recognised code for disabling time set up;
3) integration of alarm components or functions;
4) remote control duties;
5) resistance to attacks with acids;
6) resistance to X-rays;
7) resistance to explosives;
8) time functions.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
This part of the European Standard EN 1047 specifies requirements for data rooms and data containers. It includes a method of test for the determination of the ability of data rooms and data containers to protect temperature and humidity sensitive data media (see 3.5) and hardware systems (see 3.6) from the effects of fire. A test method for measuring the resistance to mechanical stress (impact test) provided by data rooms type B and data containers is also specified. Requirements are also specified for test specimens, the technical documentation of the test specimens, materials specimens, physical fittings, the correlation of test specimens with the technical documentation and the preparation for type testing as well as test procedures. In addition, a scheme to classify data rooms and data containers from the test results is given (see Table 2). As well as providing protection against fire, correctly installed data rooms and data containers offer protection against impacts caused by failure during fire of components and objects external to the data room or data container. Data rooms and data containers having the same design, protection and construction features (type and thickness of construction and protective materials, rebate geometry, lockings, doors, etc.) will only be given the same protection classification as that of the test specimen if the tolerances are within the ranges specified in Table 1.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
TC Modification to 4.4, 2nd paragraph and 7.5.5.3, 1st paragraph (concerning the mother text and not the amendment/consolidation text)
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard establishes the basis for testing and classifying free-standing safes, built-in safes (floor and wall), ATM safes and ATM bases, strongroom doors and strongrooms (with or without a door) according to their burglary resistance. This European Standard does not cover testing and classifying Deposit Systems and ATM systems.
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for high security locks (HSL) for reliability, resistance to burglary and unauthorized opening with methods of testing. It also provides a scheme for classifying HSL in accordance with their assessed resistance to burglary and unauthorised opening.
It applies to mechanical and electronic HSL. The following features may be included as optional subjects but they are not mandatory:
1) recognised code for preventing code altering and/or enabling/disabling parallel codes;
2) recognised code for disabling time set up;
3) integration of alarm components or functions;
4) remote control duties;
5) resistance to attacks with acids;
6) resistance to X-rays;
7) resistance to explosives;
8) time functions.
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 1047 specifies requirements for fire-resisting data rooms and data containers. It includes a method of test for the determination of the ability of data rooms and data containers to protect temperature and humidity sensitive contents and associated hardware systems from the effects of fire outside the data room or data container. A test method for measuring the resistance to impact of data containers and some data rooms is also specified.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard establishes the basis for testing and classifying free-standing safes, built-in safes (floor and wall), ATM safes and ATM bases, strongroom doors and strongrooms (with or without a door) according to their burglary resistance. This European Standard does not cover testing and classifying Deposit Systems and ATM systems.
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard + National Annex and/or Foreword11 pagesForeword and/or annex in Slovenian language, body of the standard in German languagesale 10% offe-Library read for1 day
- Standard – translation14 pagesSlovenian languagesale 10% offe-Library read for1 day
- Standard – translation12 pagesSlovenian languagesale 10% offe-Library read for1 day
- Standard – translation9 pagesSlovenian languagesale 10% offe-Library read for1 day
This part of this European Standard specifies requirements for fire resisting data cabinets. Two methods of test are specified to determine the ability of fire resisting data cabinets to protect temperature and humidity sensitive contents from the effects of fire: a fire endurance test and a fire shock and impact test.
- Standard – translation19 pagesSlovenian languagesale 10% offe-Library read for1 day
UAP of 4 months (TC Res 24/2000) (CC/010209)
- Amendment4 pagesEnglish languagesale 10% offe-Library read for1 day
After "(floor and wall)", add "ATM safes and ATM bases".
- Amendment14 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard + National Annex and/or Foreword32 pagesForeword and/or annex in Slovenian language, body of the standard in German languagesale 10% offe-Library read for1 day
This European standard specifies requirements for high security locks (HSL) for their reliability, resistance to burglary and unauthorized opening together with methods of test. It also gives a classification scheme for HSL according to their security.
- Standardization document34 pagesGerman languagesale 10% offe-Library read for1 day
- Standard – translation27 pagesSlovenian languagesale 10% offe-Library read for1 day