Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass break detectors (acoustic)

Change of the following chapters, to allow products to pass the relevant test section based on the relevant Annex : 6.7.4 Immunity to Hard objects hitting the glass & Annex B

Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 2-7-1: Einbruchmelder - Glasbruchmelder (Akustisch)

Systèmes d'alarme - Systèmes d'alarme contre l'intrusion et les hold-up - Partie 2-7-1: Détecteurs d'intrusion - Détecteurs bris de glace (acoustiques)

Alarmni sistemi - Sistemi za javljanje vloma in ropa - 2-7-1. del: Zahteve za javljalnike vloma - Javljalniki loma stekla (akustični) - Dopolnilo A2

General Information

Status
Published
Publication Date
28-Aug-2016
Technical Committee
EAL - Alarm systems
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
08-Jul-2016
Due Date
12-Sep-2016
Completion Date
29-Aug-2016

Relations

Effective Date
01-Sep-2016

Overview

SIST EN 50131-2-7-1:2012/A2:2016 is a vital European standard focused on alarm systems, specifically covering intrusion and hold-up systems and targeting acoustic glass break detectors. Developed by CLC/TC 79 "Alarm systems," this amendment A2 updates the original 2012 standard by refining test methods to ensure detectors perform reliably under more stringent and realistic conditions. It supports enhanced security measures against unauthorized access through glass entry points by defining immunity and detection requirements for glass break detectors.

Key Topics

  • Scope Update: The amendment revises specific chapters to allow products passing tests based on newly defined criteria in Annex 6.7.4 and Annex B.
  • Immunity to Hard Object Impact:
    • The testing angle for hard objects hitting glass has been changed from 60° ± 5° to 27° ± 1°, making defect resistance tests more representative of real-world scenarios.
  • Glass Type Specifications:
    • The standard immunity glass pane used for testing is updated from 4 mm ± 1 mm thickness to 6 mm ± 1 mm, reflecting stronger glass commonly employed in security applications.
  • Harmonization: As a European standard amendment, this document mandates compliance across all CENELEC member states, enhancing consistency and interoperability of acoustic glass break detectors across Europe.

Applications

  • Intrusion Detection Systems: SIST EN 50131-2-7-1:2012/A2:2016 guides manufacturers and installers of acoustic glass break detectors, ensuring products reliably detect break-ins through glass windows or doors.
  • Security System Design: The revised testing requirements help designers select detectors verified to resist false alarms due to impacts from hard objects, improving system accuracy and robustness.
  • Compliance and Certification: Security device manufacturers aiming for CE marking in Europe utilize this standard to demonstrate conformity with recognized alarm system performance and safety standards.
  • Commercial and Residential Security: Integral in safeguarding homes, offices, banks, and retail environments by detecting intrusions swiftly and reducing vulnerability to forced glass entry.

Related Standards

  • EN 50131 Series: Covers a broad range of intrusion and hold-up alarm system components, including detectors, control panels, and signaling devices-EN 50131-2-7-1 focusing specifically on acoustic glass break detection.
  • CENELEC Directives: This amendment aligns with CENELEC internal regulations mandating uniform implementation of standards across member states.
  • Alarm System Performance Standards: Complements EN 50131-1 and other part 2 standards that specify requirements for other types of detectors such as motion sensors, magnetic contacts, and smoke detectors.

Keywords: SIST EN 50131-2-7-1:2012/A2:2016, acoustic glass break detectors, intrusion detection systems, alarm systems standard, alarm system immunity, glass break detection, security system certification, CENELEC alarm standards, European security standards, intrusion alarm compliance

Amendment

SIST EN 50131-2-7-1:2012/A2:2016

English language
4 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 50131-2-7-1:2012/A2:2016 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass break detectors (acoustic)". This standard covers: Change of the following chapters, to allow products to pass the relevant test section based on the relevant Annex : 6.7.4 Immunity to Hard objects hitting the glass & Annex B

Change of the following chapters, to allow products to pass the relevant test section based on the relevant Annex : 6.7.4 Immunity to Hard objects hitting the glass & Annex B

SIST EN 50131-2-7-1:2012/A2:2016 is classified under the following ICS (International Classification for Standards) categories: 13.310 - Protection against crime; 13.320 - Alarm and warning systems. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 50131-2-7-1:2012/A2:2016 has the following relationships with other standards: It is inter standard links to SIST EN 50131-2-7-1:2012. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 50131-2-7-1:2012/A2:2016 is associated with the following European legislation: EU Directives/Regulations: 2020-01-0063. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

SIST EN 50131-2-7-1:2012/A2:2016 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2016
$ODUPQLVLVWHPL6LVWHPL]DMDYOMDQMHYORPDLQURSDGHO=DKWHYH]D
MDYOMDOQLNHYORPD-DYOMDOQLNLORPDVWHNOD DNXVWLþQL 'RSROQLOR$
Alarm systems - Intrusion and hold-up systems - Part 2-7-1: Intrusion detectors - Glass
break detectors (acoustic)
Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil 2-7-1: Einbruchmelder -
Glasbruchmelder (Akustisch)
Systèmes d'alarme - Systèmes d'alarme contre l'intrusion et les hold-up - Partie 2-7-1:
Détecteurs d'intrusion - Détecteurs bris de glace (acoustiques)
Ta slovenski standard je istoveten z: EN 50131-2-7-1:2012/A2:2016
ICS:
13.310 Varstvo pred kriminalom Protection against crime
13.320 Alarmni in opozorilni sistemi Alarm and warning systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 50131-2-7-1:2012/A2

NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2016
ICS 13.320
English Version
Alarm systems - Intrusion and hold-up systems - Part 2-7-1:
Intrusion detectors - Glass break detectors (acoustic)
Systèmes d'alarme - Systèmes d'alarme contre l'intrusion et Alarmanlagen - Einbruch- und Überfallmeldeanlagen - Teil
les hold-up - Partie 2-7-1: Détecteurs d'intrusion - 2-7-1: Einbruchmelder - Glasbruchmelder (Akustisch)
Détecteurs bris de glace (acoustiques)
This amendment A2 modifies the European Standard EN 50131-2-7-1:2012; it was approved by CENELEC on 2016-04-11. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the offic
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...