Cathodic protection of buried metallic tanks and related piping

This document specifies the principles for the implementation of a system of cathodic protection against corrosive attacks on buried metal tanks and associated piping.
This document specifies conditions and parameters to be met in order to achieve cathodic protection, as well as rules and procedures for the design, installation, commissioning and maintenance for the protection of buried metal tanks and associated piping.
This document is applicable to the external surfaces of buried metallic tanks and associated buried piping.
NOTE   The protection of internal surfaces is covered by EN 12499.
This document is applicable to buried tanks and associated piping, even if they are earthed by their own local earthing device, which are electrically separated from any general earthing systems and other buried structures.
Therefore tanks which are covered by the present document include:
- industrial storage tanks, irrespective of their dimensions and the nature of the stored medium (liquid or gas, flammable or not, toxic or non-toxic, polluting or not);
- tanks used at petrol stations and on domestic or commercial premises, which contain flammable liquids or gases or polluting substances.
This document is not applicable to:
- above-ground storage tank floors in contact with the ground;
- reinforced concrete containers;
- buried storage tanks that are electrically connected to the whole or a part of an industrial complex;
- buried storage tanks electrically connected to any general earthing systems.
NOTE   Cathodic protection of the last two types of tanks is covered by prEN 14505.
Measurement techniques are described in detail in EN 13509.

Kathodischer Korrosionsschutz von unterirdischen metallenen Tankanlagen und zugehörigen Rohrleitungen

In dieser Norm werden fachliche Anforderungen an Ausführung und Betrieb einer Anlage für den kathodischen Korrosionsschutz eines Objekts festgelegt. Der in dieser Norm behandelte Korrosionsschutz gilt für die Außenflächen unterirdischer metallener Tankanlagen und der zugehörigen erdverlegten Rohrleitungen. Der kathodische Korrosionsschutz der Innenflächen wird z.B. in prEN xxx1 ("Kathodischer Korrosionsschutz der Innenflächen metallischer Werkstoffe") beschrieben.

Protection cathodique des réservoirs métalliques enterrés et tuyauteries associées

La présente norme européenne spécifie les principes de mise en ?uvre d'un systeme de protection cathodique contre la corrosion des réservoirs métalliques enterrés et de leurs tuyauteries associées.
Elle indique les conditions et les parametres qu'il convient de respecter pour obtenir une protection cathodique efficace ainsi que les regles et procédures qu'il convient de suivre pour l'étude, l'installation, la mise en service, le contrôle d'efficacité et la maintenance de la protection des réservoirs métalliques enterrés et de leurs tuyauteries associées.
Cette norme s'applique aux surfaces externes de réservoirs métalliques enterrés et des tuyauteries associées.
NOTE   La protection des surfaces internes fait l'objet de l'EN 12499.
La présente Norme s'applique aux réservoirs enterrés et a leurs tuyauteries associées lorsqu'ils sont électriquement isolés de tout systeme de terre générale et autres structures enterrées.
Par conséquent, elle couvre les réservoirs suivants :
3 les réservoirs de stockage industriels quelles que soient leurs dimensions et la nature de la substance stockée (liquide ou gaz, inflammable ou non, toxique ou non-toxique, polluant ou non) ;
3 les réservoirs qui contiennent des gaz, des liquides inflammables ou des substances polluantes, utilisés dans les stations-service et les installations commerciales ou domestiques.
Elle ne s'applique pas :
3 aux fonds de réservoirs non enterrés en contact avec le sol ;
3 aux conteneurs en béton armé ;
3 aux réservoirs de stockage enterrés qui sont en contact électrique avec une partie ou la totalité d'un complexe industriel ;
3 aux réservoirs de stockage enterrés qui sont en contact électrique avec tout systeme de terre générale.
NOTE   La protection cathodique appliquée aux deux derniers types de réservoirs fait l'objet du prEN 14505 (Protection cathodique de structures complexes).
Les techniques de mesure sont décrites de maniere détaillée dans l'EN 13509.

Katodna zaščita vkopanih kovinskih rezervoarjev in pripadajočih cevovodov

General Information

Status
Published
Publication Date
31-Oct-2004
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Nov-2004
Due Date
01-Nov-2004
Completion Date
01-Nov-2004

Buy Standard

Standard
EN 13636:2004
English language
42 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.FHYRYRGRYKathodischer Korrosionsschutz von unterirdischen metallenen Tankanlagen und zugehörigen RohrleitungenProtection cathodique des réservoirs métalliques enterrés et tuyauteries associéesCathodic protection of buried metallic tanks and related piping77.060Korozija kovinCorrosion of metals23.020.10UH]HUYRDUMLStationary containers and tanksICS:Ta slovenski standard je istoveten z:EN 13636:2004SIST EN 13636:2004en01-november-2004SIST EN 13636:2004SLOVENSKI
STANDARD



SIST EN 13636:2004



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13636July 2004ICS 23.020.10; 77.060English versionCathodic protection of buried metallic tanks and related pipingProtection cathodique des réservoirs métalliques enterréset conduites associéesKathodischer Korrosionsschutz von unterirdischenmetallenen Tankanlagen und zugehörigen RohrleitungenThis European Standard was approved by CEN on 3 November 2003.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2004 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13636:2004: ESIST EN 13636:2004



EN 13636:2004 (E) 2 Contents Page Foreword.5 1 Scope.6 2 Normative references.6 3 Terms and definitions.8 4 Criteria for cathodic protection.9 5 Prerequisites for the application of cathodic protection.9 5.1 General.9 5.2 Electrical continuity.10 5.3 Electrical separation.10 5.4 External coating.10 6 Base data for design.11 6.1 General.11 6.2 Neighbouring structures.11 6.3 Soil environment.11 6.4 Tank and piping data.11 6.4.1 General.11 6.4.2 Stored medium.12 7 Design and prerequisites.12 7.1 Structure materials.12 7.2 Electrical separation.13 7.2.1 General.13 7.2.2 Isolating devices.13 7.2.3 Temporary connections.13 7.2.4 Permanently connected electrical equipment.13 7.3 Explosion hazard prevention.14 7.3.1 General.14 7.3.2 Electrical equipment installation.14 7.3.3 Isolating joints.14 7.4 Other equipment.15 7.4.1 Test station.15 7.4.2 Coupons.16 7.4.3 Mechanical connections including flanges.16 7.4.4 Sleeve pipe.16 7.4.5 Wall entries.16 7.4.6 Drainage station.16 7.4.7 Local earthing systems.16 7.5 Galvanic anode systems.16 7.5.1 General.16 7.5.2 Materials.17 7.5.3 Location.17 7.5.4 Connection of anodes to the structure.17 7.6 Impressed current systems.17 7.6.1 General.17 7.6.2 Components.17 7.7 Cables.18 7.8 Interference.19 8 Installation of cathodic protection systems.19 8.1 General.19 SIST EN 13636:2004



EN 13636:2004 (E) 3 8.2 Installation of cables.20 8.2.1 General.20 8.2.2 Cable connections to structures.20 8.3 Installation of structures to be protected.21 8.3.1 Buried structures.21 8.3.2 Above-ground structures.21 8.3.3 Isolating joints.21 8.4 Anodes.22 8.4.1 General.22 8.4.2 Galvanic anodes.22 8.4.3 Impressed current anodes.22 8.5 Impressed current station.23 8.5.1 Location.23 8.5.2 Electrical installation.23 8.6 Test stations, measuring points and coupons.23 8.7 Bondings and drainage stations.23 8.8 Labelling.23 8.9 Installation checks.24 8.10 As-built documentation.24 9 Commissioning.24 9.1 Preliminary checking.24 9.2 Start-up.25 9.3 Verification of the cathodic protection effectiveness.25 9.4 Determination of relevant measuring points.25 9.5 Commissioning documents.26 10 Inspection and maintenance.26 10.1 General.26 10.2 Inspection.26 10.2.1 General.26 10.2.2 Functional checks of equipment.27 10.2.3 Structure measurements.27 10.2.4 Inspection intervals.27 10.2.5 Inspection report.29 10.3 Maintenance.29 10.3.1 Cathodic protection equipment.29 10.3.2 Instrumentation.29 Annex A (informative) Electrical separation between the structure to be cathodically protected and the general earthing system.30 A.1 Isolation of electrical equipment.30 A.2 Electrical equipment of protection class II or III (double isolation).31 A.3 Fault current breaker with local earthing system.32 A.4 Isolating transformer.33 A.5 Example with d.c. decoupling unit.34 Annex B (informative)
Groundbed data.35 B.1 General considerations.35 B.2 Type of groundbed.35 B.2.1 General.35 B.2.2 Remote located groundbed.35 B.2.3 Close located groundbed.35 B.3 Anode type.36 B.3.1 High-silicon cast iron anodes.36 B.3.2 Mixed-metal oxide anodes.37 Annex C (informative)
Extract of pr EN 50162.38 Annex D (informative)
Determination of inspection interval.39 D.1 General.39 D.2 Complexity of the cathodic protection system.39 SIST EN 13636:2004



EN 13636:2004 (E) 4 D.3 Coating imperfections.39 D.4 Environmental conditions.40 D.5 Susceptibility to damage by lightning or mechanical impact.41 D.6 Risk of personal injury, environmental pollution or damage to property that could be caused by leakage of stored medium.41 Bibliography.42
SIST EN 13636:2004



EN 13636:2004 (E) 5 Foreword This document EN 13636:2004 has been prepared by Technical Committee CEN/TC 219 “Cathodic protection”, the secretariat of which is held by BSI. This document shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2005, and conflicting national standards shall be withdrawn at the latest by January 2005. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. This document, which deals with buried metallic tanks and associated piping, takes into account the specific features of buried tanks in terms of construction, electrical equipment and safety considerations. The present document only covers the technical aspects of corrosion protection of tanks and associated piping. The application of cathodic protection depends on national requirements and the factors outlined in EN 12954:2001, Clause 5. EN 12954, also prepared by CEN TC 219/WG1, is concerned with cathodic protection against corrosion of buried or immersed metallic structures and gives general principles applicable to the protection of all types of such structures. Cathodic protection is a technique based on the application of electrochemical principles and covers a wide variety of materials and equipment together with a variety of measurement techniques. It is assumed in the drafting of this document that the design, installation, commissioning, inspection and maintenance are entrusted to adequately trained, experienced, competent and reliable personnel in order to achieve effective and efficient cathodic protection. SIST EN 13636:2004



EN 13636:2004 (E) 6 1 Scope This document specifies the principles for the implementation of a system of cathodic protection against corrosive attacks on buried metal tanks and associated piping. This document specifies conditions and parameters to be met in order to achieve cathodic protection, as well as rules and procedures for the design, installation, commissioning and maintenance for the protection of buried metal tanks and associated piping. This document is applicable to the external surfaces of buried metallic tanks and associated buried piping.
NOTE The protection of internal surfaces is covered by EN 12499. This document is applicable to buried tanks and associated piping, even if they are earthed by their own local earthing device, which are electrically separated from any general earthing systems and other buried structures. Therefore tanks which are covered by the present document include:
 industrial storage tanks, irrespective of their dimensions and the nature of the stored medium (liquid or gas, flammable or not, toxic or non-toxic, polluting or not);  tanks used at petrol stations and on domestic or commercial premises, which contain flammable liquids or gases or polluting substances. This document is not applicable to:  above-ground storage tank floors in contact with the ground;  reinforced concrete containers;  buried storage tanks that are electrically connected to the whole or a part of an industrial complex;  buried storage tanks electrically connected to any general earthing systems. NOTE Cathodic protection of the last two types of tanks is covered by prEN 14505.
Measurement techniques are described in detail in EN 13509. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12954:2001, Cathodic protection of buried or immersed metallic structures — General principles and application for pipelines. prEN 14505:2002, Cathodic protection of complex structures. EN 50014, Electrical apparatus for potentially explosive atmospheres — General requirements. EN 50016, Electrical apparatus for potentially explosive atmospheres — Pressurized apparatus “p”. SIST EN 13636:2004



EN 13636:2004 (E) 7 EN 50017, Electrical apparatus for potentially explosive atmospheres — Powder filling “q”. EN 50018, Electrical apparatus for potentially explosive atmospheres — Flameproof enclosures “d”. EN 50019, Electrical apparatus for potentially explosive atmospheres — Increased safety “e”. EN 50020, Electrical apparatus for potentially explosive atmospheres — Intrinsic safety “i”. EN 50021, Electrical apparatus for potentially explosive atmospheres — Types of protection “n”. EN 50028, Electrical apparatus for potentially explosive atmospheres — Encapsulation “m”. EN 50039, Electrical apparatus for potentially explosive atmospheres — Intrinsically safe electrical systems “i”. EN 50162:2003, Protection against corrosion by stray current from direct current systems. EN 60079-10, Electrical apparatus for explosive gas atmospheres — Part 10: Classification of hazardous areas (IEC 60079—10:1995). EN 60742, Isolating transformers and safety isolating transformers — Requirements (IEC 60742:1983 + A1:1992, modified). EN 61140, Protection against electric shock — Common aspects for installation and equipment (IEC 61140:2001). EN ISO 8044:1999, Corrosion of metals and alloys — Basic terms and definitions (ISO 8044:1999). IEC 60587, Methods for evaluating resistance to tracking and erosion of electrical insulating materials used under severe ambient conditions. SIST EN 13636:2004



EN 13636:2004 (E) 8
3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 12954, EN 60079-10, EN ISO 8044 and the following apply. 3.1 electrical connection (electrically connected) connection allowing the flow of electrons between two different metallic structures
Figure 1 — Example of bonding permitting flow of current 3.2 electrical separation (electrically separated) separation of two different metallic structures to prevent the flow of electrons between them
Figure 2 — Example of isolation to prevent the flow of currrent
3.3 associated piping all metallic process piping that is electrically connected to a buried tank and is protected by the cathodic protection system of the tank 3.4 local earthing system local earthing system for the structure under consideration which is electrically separated from any other general earthing e.g. welding metallic bond or cableStructure1Structure2Structure1Structure2Structure1Structure2Structure 1 Structure 2Structure 1 Structure 2Isolating material SIST EN 13636:2004



EN 13636:2004 (E) 9 3.5 shield conductive or non conductive structure or object, which modifies the protection current distribution on a structure to be protected 4 Criteria for cathodic protection The metal to electrolyte potential at which the corrosion rate is < 0,01 mm per year is the protection potential, Ep. This corrosion rate is sufficiently low so that during the design lifetime corrosion damage cannot occur. The criterion for cathodic protection is therefore:
E ≤ Ep where
E is the metal to electrolyte potential For carbon steel in soils with resistivities of ρ < 100 Ωm and in the absence of sulfate reducing bacteria, the protection potential versus a Cu/CuSO4 saturated reference electrode, Ep,, is -0,85 V. Special measures in accordance with EN 12954:2001, Table 1, shall be taken for steel with high yield strengths to avoid hydrogen-induced cracking. NOTE 1 Full details of the principle and criteria of cathodic protection are given in EN 12954:2001, Clause 4. NOTE 2 On well insulated tanks where the potential criterion is difficult to verify, the effectiveness of cathodic protection can be checked by measurement via a coupon (see 7.4.2). 5 Prerequisites for the application of cathodic protection 5.1 General The different tank systems to be cathodically protected should be separate from each other. NOTE 1 The separation distance depends on the diameter, the length and above all the average coating resistance of the tanks. It also depends on the location (close or remote) of the groundbed in relation to the cathodically protected structure. NOTE 2 The design of cathodic protection for tank systems depends on the location and the extent of the structure, the kind of embedding material, the soil resistivity, the coating (type, coating resistance etc.) and also on general safety requirements. For well-coated tanks the separation distance should be a minimum of 0,40 m between tanks. The cathodically protected structure should be sufficiently remote from any other buried structure so that these foreign structures do not act as a shield for the structure to be cathodically protected and do not suffer from interference effects. For well-coated tanks, the distance between cathodically protected and foreign structures should be a minimum of 1,0 m. Where the tanks being cathodically protected are enclosed within steel reinforced concrete retaining walls, special attention shall be given to avoid: a) detrimental effects of the cathodic protection currents upon the steel reinforcement; SIST EN 13636:2004



EN 13636:2004 (E) 10 b) metallic contact between the steel reinforcement and the tank. NOTE Metallic contact between the steel reinforcement and the tank would reduce the current entering the tank. 5.2 Electrical continuity The structure or a section of the whole structure to be cathodically protected shall be electrically continuous, with a low longitudinal resistance. The components which can increase the longitudinal resistance of the structure should be short-circuited, e.g. by using cables with a suitable cross-sectional area as described in 7.7. Bonds should be capable of being temporarily disconnected for measuring purposes. 5.3 Electrical separation Tanks to be cathodically protected shall have no metallic contact with: a) parts of structures which are not to be cathodically protected; b) earthed foreign structures (e.g. reinforcement steel); c) general earthing systems even those made of galvanized steel. When earthing is necessary for safety reasons (e.g. for electrical equipment, lightning and explosion protection) special measures shall be taken, as given in accordance with 7.2.3, 7.2.4 and 7.4.7. 5.4 External coating The structure to be cathodically protected should normally be provided with an efficient external coating in order to: a) provide sufficient corrosion protection;
b) reduce protection current demand;
c) improve current distribution; and
d) reduce interference to other foreign structures. The coating should: a) be compatible with cathodic protection; and b) be resistant to the stored fluid. NOTE In some cases, with structures comprising different metals, it can only be necessary to cover the more cathodic metal (see 7.1, Note a). On structures which are bare or poorly coated, e.g. an existing tank, cathodic protection shall be applied with care to avoid electrical interference. SIST EN 13636:2004



EN 13636:2004 (E) 11 6 Base data for design 6.1 General Str
...