SIST ISO 8761:1996/Cor 1:2011
(Corrigendum)Work-place air - Determination of mass concentration of nitrogen dioxide - Method using detector tubes for short-term sampling with direct indication - Corrigendum
Work-place air - Determination of mass concentration of nitrogen dioxide - Method using detector tubes for short-term sampling with direct indication - Corrigendum
Specifies a procedure for the range of approximately 1 mg/m3 to 50 mg/m3. Substances which are known to have an effect on the instrument reading are indicated. The procedure is suitable for personal, breathing-zone sampling as well as for the general area sampling.
Air des lieux de travail - Détermination de la concentration en masse du dioxyde d'azote - Méthode utilisant des tubes détecteurs pour échantillonnage rapide à lecture directe - Rectificatif
Zrak na delovnem mestu - Določevanje masne koncentracije dušikovega dioksida - Metoda uporabe detekcijskih cevk z neposrednim odčitavanjem ob kratkotrajnem vzorčenju - Popravek
Določa postopek za razpon med približno 1 mg/m3 in 50 mg/m3. Navedene so snovi, ki znano vplivajo na merilni instrument. Postopek je primeren za vzorčenje v osebnem dihalnem območju in za vzorčenje v splošnem območju.
General Information
- Status
- Published
- Publication Date
- 21-Nov-2011
- Technical Committee
- KAZ - Air quality
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 26-Oct-2011
- Due Date
- 31-Dec-2011
- Completion Date
- 22-Nov-2011
Relations
- Effective Date
- 01-Dec-2011
- Effective Date
- 01-Jan-2022
Overview
SIST ISO 8761:1996/Cor 1:2011 is an essential technical corrigendum to the international standard ISO 8761:1989, which specifies the method for determining the mass concentration of nitrogen dioxide (NO₂) in workplace air. This corrigendum provides updates related to the use of detector tubes for short-term sampling with direct indication. Developed by ISO Technical Committee ISO/TC 146, Subcommittee SC 2, focused on workplace atmospheres, this corrigendum ensures improved accuracy and reliability in monitoring nitrogen dioxide concentrations in occupational environments.
The standard is critical for industries and health and safety professionals aiming to monitor and control NO₂ exposure to safeguard worker health. Nitrogen dioxide is a harmful gas commonly found in urban air pollution and industrial emissions, and accurate measurement methods are crucial for compliance with occupational exposure limits.
Key Topics
Measurement Method
The standard addresses the use of detector tubes for short-term sampling of NO₂ in workplace air with direct concentration indication. This approach facilitates rapid and on-site monitoring without requiring complex laboratory analysis.Accuracy and Error Limits
A vital update included in the corrigendum specifies that the reading error must be less than 4 ppm (4 ml per 10 ml sample volume). If the error exceeds this threshold, the maximum random error would surpass 25%, impacting the reliability of the measurement.Technical Corrigendum Details
The corrigendum provides a precise amendment in paragraph 9.2 of the original standard, improving the clarity of error tolerances and strengthening the validity of measurement results.Standardization and Compliance
As part of ISO’s broader air quality management standards, SIST ISO 8761:1996/Cor 1:2011 aligns with international guidelines aimed at protecting workplace environments from hazardous airborne pollutants.
Applications
Occupational Health Monitoring
The method supports workplace safety officers and industrial hygienists in assessing exposure levels to nitrogen dioxide, enabling timely interventions to reduce health risks associated with respiratory irritation and long-term lung damage.Industrial Environmental Control
Industries such as manufacturing, automotive, and chemical processing can implement this standard to monitor emissions and maintain compliance with air quality regulations.Rapid Field Testing
The use of detector tubes facilitates immediate, on-site testing, suitable for routine inspections, emergency assessments, or preliminary exposure evaluation before comprehensive laboratory analysis.Regulatory Compliance
Enables organizations to fulfill statutory requirements concerning workplace air quality by providing a standardized, validated measurement protocol recognized internationally.
Related Standards
ISO 14698 - Air Quality Standards
Covers broader aspects of workplace atmospheres and air contaminants, complementing the methods for nitrogen dioxide measurement.ISO 4225 - Air Quality Vocabulary
Provides definitions relevant to the terminology used in the monitoring and measurement of nitrogen dioxide and other airborne pollutants.ISO 10882 - Workplace Atmosphere Monitoring Techniques
Addresses various sampling methods for different airborne substances, useful for organizations looking to implement comprehensive air quality assessments.
Keywords: SIST ISO 8761:1996/Cor 1:2011, nitrogen dioxide measurement, workplace air quality, detector tubes, short-term sampling, NO₂ concentration, occupational health, air quality standard, technical corrigendum, air pollution monitoring, ISO standards workplace atmosphere.
Frequently Asked Questions
SIST ISO 8761:1996/Cor 1:2011 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Work-place air - Determination of mass concentration of nitrogen dioxide - Method using detector tubes for short-term sampling with direct indication - Corrigendum". This standard covers: Specifies a procedure for the range of approximately 1 mg/m3 to 50 mg/m3. Substances which are known to have an effect on the instrument reading are indicated. The procedure is suitable for personal, breathing-zone sampling as well as for the general area sampling.
Specifies a procedure for the range of approximately 1 mg/m3 to 50 mg/m3. Substances which are known to have an effect on the instrument reading are indicated. The procedure is suitable for personal, breathing-zone sampling as well as for the general area sampling.
SIST ISO 8761:1996/Cor 1:2011 is classified under the following ICS (International Classification for Standards) categories: 13.040.30 - Workplace atmospheres. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST ISO 8761:1996/Cor 1:2011 has the following relationships with other standards: It is inter standard links to SIST ISO 8761:1996; is excused to SIST ISO 8761:1996. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST ISO 8761:1996/Cor 1:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
INTERNATIONAL STANDARD ISO 8761:1989
TECHNICAL CORRIGENDUM 1
Published 2009-07-15
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION • МЕЖДУНАРОДНАЯ ОРГАНИЗАЦИЯ ПО СТАНДАРТИЗАЦИИ • ORGANISATION INTERNATIONALE DE NORMALISATION
Work-place air — Determination of mass concentration of
nitrogen dioxide — Method using detector tubes for short-term
sampling with direct indication
TECHNICAL CORRIGENDUM 1
Air des lieux de travail — Détermination de la concentration en masse du dioxyde d'azote — Méthode utilisant
des tubes détecteurs pour échantillonnage rapide à lecture directe
RECTIFICATIF TECHNIQUE 1
...
NORME INTERNATIONALE ISO 8761:1989
RECTIFICATIF TECHNIQUE 1
Publié 2009-07-15
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION • МЕЖДУНАРОДНАЯ ОРГАНИЗАЦИЯ ПО СТАНДАРТИЗАЦИИ • ORGANISATION INTERNATIONALE DE NORMALISATION
Air des lieux de travail — Détermination de la concentration en
masse du dioxyde d'azote — Méthode utilisant des tubes
détecteurs pour échantillonnage rapide à lecture directe
RECTIFICATIF TECHNIQUE 1
Work-place air — Determination of mass concentration of nitrogen dioxide — Method using detector tubes for
short-term sampling with direct indication
TECHNICAL CORRIGENDUM 1
Le Rectificatif t
...
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.DWNRWUDMQHPAir des lieux de travail - Détermination de la concentration en masse du dioxyde d'azote - Méthode utilisant des tubes détecteurs pour échantillonnage rapide à lecture directe - RectificatifWork-place air - Determination of mass concentration of nitrogen dioxide - Method using detector tubes for short-term sampling with direct indication - Corrigendum13.040.30Kakovost zraka na delovnem mestuWorkplace atmospheresICS:Ta slovenski standard je istoveten z:ISO 8761:1989/Cor 1:2009SIST ISO 8761:1996/Cor 1:2011en,fr01-december-2011SIST ISO 8761:1996/Cor 1:2011SLOVENSKI
STANDARD
ICS
13.040.30 Ref. No. ISO 8761:1989/Cor.1:2009(E)©
ISO 2009 – All rights reserved Published in Switzerland
INTERNATIONAL STANDARD ISO 8761:1989 TECHNICAL CORRIGENDUM 1 Publish
...


















Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...