kSIST FprEN 13598-1:2026
(Main)Plastics piping systems for non-pressure underground drains and sewers - Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 1: Specifications for ancillary fittings and shallow chambers
- Abstract
This document specifies the definitions and requirements for unplasticized polyvinyl chloride (PVC-U), polypropylene (PP) and polyethylene (PE) ancillary fittings and shallow chambers intended for use in non-pressure underground drains and sewers for wastewater.
This document is applicable to:
a) ancillary fittings and shallow chambers, intended for use buried underground outside the building structure, reflected in the marking of products by “U”;
b) ancillary fittings and shallow chambers, intended for use buried underground both outside (application area code “U”) and within the building structure, reflected in the marking of products by “UD”.
This document also covers the jointing of the ancillary fittings and shallow chambers to the piping system.
The document is applicable to the following ancillary fittings:
— sealed access fittings;
— rodding point covers;
— rodding tees;
— mechanical saddles.
Ancillary fittings according to this document are intended for use in pedestrian areas, except rodding tees and mechanical saddles which can also be used in vehicular trafficked areas.
Ancillary fittings, with the exception of rodding point covers, can be installed to a maximum depth of 6,0 m from ground level. Rodding point covers can be installed to a maximum depth of 2,0 m from ground level.
Shallow chambers according to this document are intended for use in private drains located in pedestrian areas above the ground water table, to a maximum depth of 2,0 m from ground level to the invert of the main shallow chamber flow channel. This document covers shallow chambers having a base with a shallow chamber flow channel and their joints to the piping system.
Ancillary fittings and shallow chambers can be manufactured by various methods e.g. injection moulding, rotational moulding, spiral winding or fabricated.
NOTE 1 Products complying with this document can be used with pipes, fittings and other components conforming to any of the plastics products standards listed in Annex E, providing their dimensions are compatible.
NOTE 2 Products complying with this document can be installed in underground applications without additional static calculation.
NOTE 3 Ancillary fittings and shallow chambers can be subject to national regulations and / or local provisions.
- Status
- Not Published
- Public Enquiry End Date
- 30-Jan-2026
- Technical Committee
- PCV - Plastic pipes, fittings and valves
- Current Stage
- 5020 - Formal vote (FV) (Adopted Project)
- Start Date
- 19-Oct-2026
- Due Date
- 07-Dec-2026
- Completion Date
- 19-Oct-2026
kSIST FprEN 13598-1:2026 is the Slovenian draft adoption of prEN 13598-1, a European standard from CEN for plastics piping systems used in non-pressure underground drains and sewers for wastewater. It specifies definitions and requirements for unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) ancillary fittings and shallow chambers, including how they are jointed to the piping system.
For manufacturers, test laboratories, designers and buyers of drainage components, the document tells you which product types are covered, which materials and dimensions are acceptable, which performance tests apply, and what marking and installation information must accompany the product.
What does kSIST FprEN 13598-1:2026 specify?
kSIST FprEN 13598-1:2026 specifies the requirements for PVC-U, PP and PE ancillary fittings and shallow chambers used in non-pressure underground wastewater drains and sewers. It applies to products buried outside buildings, and also to products marked for use both outside and within the building structure.
The document also covers the jointing of these fittings and chambers to the piping system. It is intended for pedestrian areas, with some product types also allowed in vehicular trafficked areas.
Scope highlights
- Ancillary fittings: sealed access fittings, rodding point covers, rodding tees and mechanical saddles
- Shallow chambers: bases with a shallow chamber flow channel and their joints to the piping system
- Depth limits: different limits apply to ancillary fittings, rodding point covers and shallow chambers
- Product marking: use area codes U and UD to show the intended application area
| Annex | What it covers |
|---|---|
| Annex A | Material characteristics for shallow chamber components |
| Annex B | Use of recyclates for shallow chambers |
| Annex C | Test methods for mechanical saddles |
| Annex D | Resistance to vertical loading of shallow chambers |
| Annex E | Informative list of compatible product standards |
What are the key requirements of kSIST FprEN 13598-1:2026?
kSIST FprEN 13598-1:2026 sets requirements across material selection, geometry, mechanical performance, watertightness, and marking. In practice, this means the manufacturer has to design the component, choose compatible materials, and prove by test that the assembled product performs as required.
Material and compatibility
Clause 5 links ancillary fittings to the relevant system standards for PVC-U, PP, PE and PP with mineral modifiers. For shallow chambers, Annex A defines the material characteristics, and Annex B controls recyclates. This matters because the material choice is part of conformity, not just the product shape.
General appearance and assembly
Clause 6 requires smooth, clean internal and external surfaces and cleanly cut spigots. It also allows assemblies made from two or more plastics components, and permits additional items such as covers, frames and gratings if they comply with the relevant EN 124 part. In practice, the finished assembly still has to meet the standard as a whole.
Geometry and fit
Clause 7 requires the manufacturer to declare relevant dimensions and tolerances, with dimensions measured according to EN ISO 3126. It sets minimum wall thickness and size requirements for ancillary fittings, and it requires shallow chamber joints to maintain invert continuity within defined tolerances. That is important because the system must connect to compatible pipework without creating offsets that can affect flow or cleaning.
Mechanical performance
Clause 8 assigns mechanical requirements to the main product groups:
- sealed access fittings and rodding tees
- mechanical saddles
- shallow chambers
- fabricated fittings
The clause also links rodding point covers to EN 124 or EN 1253, as applicable. For users, this means the fitting has to withstand the relevant load and impact conditions for its intended location and use.
Physical and performance testing
Clause 9 covers physical characteristics of ancillary fittings, including watertightness for fabricated fittings. Clause 10 covers fitness for purpose of the joints and systems, including tightness under deflection, elevated temperature cycling, and watertightness. For shallow chambers, clause 10 also includes water tightness and shear resistance. This is the part that shows whether the installed jointing system remains leak-tight and serviceable.
Materials used in joints and fixing
Clauses 12 and 13 control sealing rings and adhesives. Sealing rings must comply with the relevant EN 681 part, and adhesives must comply with EN 14680, with EN 14814 allowed as an alternative. In practice, the joining materials must not damage the components or cause the test assembly to fail.
Marking and documentation
Clause 14 requires durable marking, including the standard number, application area code, manufacturer identification, nominal size and material. It also requires installation guidance for shallow chambers and mechanical saddles. That helps traceability on site and gives installers the data they need for correct assembly.
What terms does kSIST FprEN 13598-1:2026 define?
- Application area code - A marking code that shows whether the product is intended for area U or UD use.
- Sealed access fitting - A fitting that allows rodding or inspection through a sealed cover.
- Rodding point cover - A ground-level fitting with a removable cover for introducing inspection or blockage-clearing equipment.
- Mechanical saddle - A fitting that creates a branch connection by cutting into a larger buried pipe and holding the branch in place mechanically.
- Shallow chamber - A shallow underground fitting for cleaning and inspection from surface level, but not for personnel access.
- Shallow chamber base - The bottom part of a shallow chamber, including the formed flow channel and benching as appropriate.
- Recyclate - Plastics material made from recycled pre-consumer and post-consumer plastics products.
- Virgin material - Plastics material that has not been previously used or processed beyond its initial manufacture.
Who uses kSIST FprEN 13598-1:2026?
kSIST FprEN 13598-1:2026 is used by manufacturers of drainage fittings and shallow chambers, especially makers of PVC-U, PP and PE components. It is also used by test laboratories that verify impact strength, watertightness, ring stiffness, deflection and loading performance.
Designers, specifiers and buyers use it when selecting components for non-pressure underground wastewater drainage systems. Quality managers use it to check material control, traceability, marking and conformity documentation. Installers and contractors use the installation and jointing information, especially for shallow chambers and mechanical saddles.
What changed in kSIST FprEN 13598-1:2026 from the previous edition?
kSIST FprEN 13598-1:2026 will supersede EN 13598-1:2020. The foreword states these changes from the previous edition:
- terminology was updated to align with the TC155 Oslo agreement and EN 14541-1
- additional terms and definitions were added
- material clauses and Annex A were updated
- the format of units and symbols in tables was updated
- test methods were updated to the latest EN ISO standards where applicable
- terms, definitions, symbols and figures were updated
- mechanical characteristics tables were updated
- the resistance to vacuum characteristic was replaced by structural integrity of base
- limits were added for horizontal and vertical deflection
Which standards are used with kSIST FprEN 13598-1:2026?
The standard builds on these referenced and companion standards:
| Reference | What it contributes |
|---|---|
| EN 124 (all parts) | Requirements for gully tops and manhole tops used with some ancillary fittings |
| EN 476 | General requirements for drain and sewer components |
| EN 681-1 to EN 681-4 | Material requirements for elastomeric sealing rings |
| EN 1401-1, EN 1852-1, EN 12666-1, EN 13476, EN 14758-1 | Pipe, fitting and system requirements used for compatibility and material rules |
| EN 14680 | Adhesive requirements for thermoplastic piping systems |
| EN ISO 3126 | Dimension measurement method |
| EN ISO 13254, EN ISO 13257, EN ISO 13259 | Watertightness, temperature cycling and joint leak-tightness test methods |
| EN ISO 13263, EN ISO 13264, EN ISO 13268 | Impact, fabricated fitting strength and ring stiffness test methods |
| EN ISO 472, EN ISO 1043-1 | Vocabulary and abbreviated terms for plastics |
What does the kSIST FprEN 13598-1:2026 document contain?
The document contains a full specification structure: scope, normative references, terms and definitions, symbols and abbreviations, material requirements, general characteristics, geometry, mechanical characteristics, physical characteristics, performance requirements, product characterization, sealing rings, adhesives, marking and documentation. It uses tables to state the required properties and the test methods that apply.
Figures illustrate typical sealed access fittings, rodding point covers, rodding tees, mechanical saddles and shallow chambers. Annex C gives the practical test set-ups for mechanical saddles, and Annex D gives the loading test arrangement for shallow chambers. Annex A and Annex B provide the material-control rules needed for assessment of conformity, including recyclate use.
Relations
- Effective Date
- 09-Oct-2024
Get Certified
Connect with accredited certification bodies for this standard
Institut za varilstvo d.o.o. (Welding Institute)
Slovenia's leading welding institute since 1952. ISO 3834, EN 1090, pressure equipment certification, NDT personnel, welder qualification. Only IIW Au

Zavod za gradbeništvo Slovenije (ZAG) - Inšpekcija
ZAG inspection body for construction products, structures, and materials.
Sponsored listings
Frequently Asked Questions
kSIST FprEN 13598-1:2026 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Plastics piping systems for non-pressure underground drains and sewers - Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 1: Specifications for ancillary fittings and shallow chambers". This standard covers: This document specifies the definitions and requirements for unplasticized polyvinyl chloride (PVC-U), polypropylene (PP) and polyethylene (PE) ancillary fittings and shallow chambers intended for use in non-pressure underground drains and sewers for wastewater. This document is applicable to: a) ancillary fittings and shallow chambers, intended for use buried underground outside the building structure, reflected in the marking of products by “U”; b) ancillary fittings and shallow chambers, intended for use buried underground both outside (application area code “U”) and within the building structure, reflected in the marking of products by “UD”. This document also covers the jointing of the ancillary fittings and shallow chambers to the piping system. The document is applicable to the following ancillary fittings: — sealed access fittings; — rodding point covers; — rodding tees; — mechanical saddles. Ancillary fittings according to this document are intended for use in pedestrian areas, except rodding tees and mechanical saddles which can also be used in vehicular trafficked areas. Ancillary fittings, with the exception of rodding point covers, can be installed to a maximum depth of 6,0 m from ground level. Rodding point covers can be installed to a maximum depth of 2,0 m from ground level. Shallow chambers according to this document are intended for use in private drains located in pedestrian areas above the ground water table, to a maximum depth of 2,0 m from ground level to the invert of the main shallow chamber flow channel. This document covers shallow chambers having a base with a shallow chamber flow channel and their joints to the piping system. Ancillary fittings and shallow chambers can be manufactured by various methods e.g. injection moulding, rotational moulding, spiral winding or fabricated. NOTE 1 Products complying with this document can be used with pipes, fittings and other components conforming to any of the plastics products standards listed in Annex E, providing their dimensions are compatible. NOTE 2 Products complying with this document can be installed in underground applications without additional static calculation. NOTE 3 Ancillary fittings and shallow chambers can be subject to national regulations and / or local provisions.
This document specifies the definitions and requirements for unplasticized polyvinyl chloride (PVC-U), polypropylene (PP) and polyethylene (PE) ancillary fittings and shallow chambers intended for use in non-pressure underground drains and sewers for wastewater. This document is applicable to: a) ancillary fittings and shallow chambers, intended for use buried underground outside the building structure, reflected in the marking of products by “U”; b) ancillary fittings and shallow chambers, intended for use buried underground both outside (application area code “U”) and within the building structure, reflected in the marking of products by “UD”. This document also covers the jointing of the ancillary fittings and shallow chambers to the piping system. The document is applicable to the following ancillary fittings: — sealed access fittings; — rodding point covers; — rodding tees; — mechanical saddles. Ancillary fittings according to this document are intended for use in pedestrian areas, except rodding tees and mechanical saddles which can also be used in vehicular trafficked areas. Ancillary fittings, with the exception of rodding point covers, can be installed to a maximum depth of 6,0 m from ground level. Rodding point covers can be installed to a maximum depth of 2,0 m from ground level. Shallow chambers according to this document are intended for use in private drains located in pedestrian areas above the ground water table, to a maximum depth of 2,0 m from ground level to the invert of the main shallow chamber flow channel. This document covers shallow chambers having a base with a shallow chamber flow channel and their joints to the piping system. Ancillary fittings and shallow chambers can be manufactured by various methods e.g. injection moulding, rotational moulding, spiral winding or fabricated. NOTE 1 Products complying with this document can be used with pipes, fittings and other components conforming to any of the plastics products standards listed in Annex E, providing their dimensions are compatible. NOTE 2 Products complying with this document can be installed in underground applications without additional static calculation. NOTE 3 Ancillary fittings and shallow chambers can be subject to national regulations and / or local provisions.
kSIST FprEN 13598-1:2026 is classified under the following ICS (International Classification for Standards) categories: 23.040.05 - Pipelines and its parts for external sewage systems; 23.040.20 - Plastics pipes; 93.030 - External sewage systems. The ICS classification helps identify the subject area and facilitates finding related standards.
kSIST FprEN 13598-1:2026 has the following relationships with other standards: It is inter standard links to SIST EN 13598-1:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
kSIST FprEN 13598-1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 application area code
- 3.2 drain
- 3.3 sewer
- 3.4 wastewater
- 3.4.1 foul wastewater
- 3.4.2 surface water
- 3.4.3 domestic wastewater
- 3.4.4 industrial wastewater
- 3.5 private drain
- 3.6 pedestrian area
- 3.7 sealed access fitting
- 3.8 rodding point cover
- 3.9 rodding tee
- 3.10 mechanical saddle
- 3.11 shallow chamber
- 3.12 shallow chamber base
- 3.13 flow channel
- 3.14 benching
- 3.15 invert
- 3.16 shallow chamber riser
- 3.17 assembly
- 3.18 fabricated fitting
- 3.19 virgin material
- 3.20 reworked material
- 3.21 pre-consumer material
- 3.22 post-consumer material
- 3.23 recyclate
- 3.24 agreed specification
- 4 Symbols and abbreviations
- 4.1 Symbols
- 4.2 Abbreviations
- 5 Material
- 5.1 Ancillary fittings
- 5.2 Shallow chambers
- 5.3 Sealing ring retaining components
- 6 General characteristics
- 6.1 Appearance
- 6.2 Colour
- 6.3 Assemblies
- 7 Geometrical characteristics
- 7.1 General
- 7.2 Design lengths
- 7.3 Dimensions of ancillary fittings
- 7.4 Dimensions of shallow chambers
- 7.5 Additional requirements for sealed access fittings
- 8 Mechanical characteristics
- Annex B
- 5.3 Deflection of cover shall conform Loading
- 9 Physical characteristics of ancillary fittings
- 9.1 Injection moulded fittings
- 9.2 Fabricated fittings
- 10 Performance requirements
- 11 Characterization of rotationally moulded product submitted for performance
- 12 Sealing rings
- 13 Adhesives
- 14 Marking and additional documentation
- 14.1 General
- 14.2 Minimum required marking, sealed access fittings and rodding tees
- 14.3 Minimum required marking, mechanical saddles
- 14.4 Minimum required marking, shallow chambers
- 14.5 Additional documentation, shallow chambers
- 14.6 Additional documentation, mechanical saddles
- Annex A
- Annex B
- Annex C
- Annex D
- Annex E
- Bibliography
1 Scope
This document is part of a System Standard for plastics piping systems of a particular material for a specified application. There are a number of such System Standards. System Standards are based on the results of the work being undertaken in ISO/TC 138 “Plastics pipes, fittings and valves for the transport of fluids”, which is a Technical Committee of the International Organization for Standardization (ISO).
They are supported by separate standards on test methods, to which references are made throughout the System Standard.
The System Standards are consistent with general standards on functional requirements and on recommended practice for installation.
This document specifies the definitions and requirements for unplasticized polyvinyl chloride (PVC-U), polypropylene (PP) and polyethylene (PE) ancillary fittings and shallow chambers intended for use in non-pressure underground drains and sewers for wastewater.
This document is applicable to:
a) ancillary fittings and shallow chambers, intended for use buried underground outside the building structure; reflected in the marking of products by “U”; b) ancillary fittings and shallow chambers, intended for use buried underground both outside (application area code “U”) and within the building structure, reflected in the marking of products by “UD”.
This document also covers the jointing of the ancillary fittings and shallow chambers to the piping system. The document is applicable to the following ancillary fittings:
- sealed access fittings;
- rodding point covers;
- rodding tees;
- mechanical saddles.
Ancillary fittings according to this document are intended for use in pedestrian areas, except rodding tees and mechanical saddles which can also be used in vehicular trafficked areas. Ancillary fittings can be installed to a maximum depth of 6,0 m from ground level, with the exception of rodding point covers with a maximum depth of 2,0 m.
Shallow chambers according to this document are intended for use in private drains located in pedestrian areas above the ground water table, to a maximum depth of 2,0 m from ground level to the invert of the main flow channel. This document covers shallow chambers having a base with a flow channel and their joints to the piping system.
Ancillary fittings and shallow chambers can be manufactured by various methods e.g. injection moulding, rotational moulding, spiral winding or fabricated.
NOTE 1 Products complying with this document can be used with pipes, fittings and other components conforming to any of the plastics products standards listed in Annex E, providing their dimensions are compatible. NOTE 2 Products complying with this document can be installed in underground applications without additional static calculation.
oSIST prEN 13598-1:2026 prEN 13598-1:2025 (E) NOTE 3 Ancillary fittings and shallow chambers can be subject to national regulations and / or local provisions.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 124 (all parts), Gully tops and manhole tops for vehicular and pedestrian areas EN 295-3:2012, Vitrified clay pipe systems for drains and sewers – Part 3: Test methods EN 476, General requirements for components used in drains and sewers EN 681-1, Elastomeric seals – Materials requirements for pipe joint seals used in water and drainage applications – Part 1: Vulcanized rubber EN 681-2, Elastomeric Seals – Materials requirements for pipe joint seals used in water and drainage applications – Part 2: Thermoplastic elastomers EN 681-3, Elastomeric seals – Materials requirements for pipe joint seals used in water and drainage applications – Part 3: Cellular materials of vulcanized rubber EN 681-4, Elastomeric seals – Materials requirements for pipe joint seals used in water and drainage applications – Part 4: Cast polyurethane sealing elements EN 1253-2:2015, Gullies for buildings - Part 2: Roof drains and floor gullies without trap EN 1401-1, Plastics piping systems for non-pressure underground drainage and sewerage – Unplasticized poly(vinyl chloride) (PVC-U) – Part 1: Specifications for pipes, fittings and the system EN 1852-1, Plastics piping systems for non-pressure underground drainage and sewerage – Polypropylene (PP) – Part 1: Specifications for pipes, fittings and the system EN 12099, Plastics piping systems – Polyethylene piping materials and components – Determination of volatile content EN 12666-1, Plastics piping systems for non-pressure underground drainage and sewerage – Polyethylene (PE) – Part 1: Specifications for pipes, fittings and the system EN 13476 (all parts), Plastics piping systems for non-pressure underground drains and sewers – Structuredwall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) EN 13476-1, Plastics piping systems for non-pressure underground drains and sewers – Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) – Part 1:General requirements and performance characteristics EN 13476-2, Plastics piping systems for non-pressure underground drains and sewers – Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) – Part 2: Specifications for pipes and fittings with smooth internal and external surface and the system, Type A
oSIST prEN 13598-1:2026 prEN 13598-1:2025 (E) EN 13476-3, Plastics piping systems for non-pressure underground drains and sewers – Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) – Part 3: Specifications for pipes and fittings with smooth internal and profiled external surface and the system, Type B EN 14680, Adhesives for non-pressure thermoplastics piping systems – Specifications EN 14758-1, Plastics piping systems for non-pressure underground drainage and sewerage – Polypropylene with mineral modifiers (PP-MD) – Part 1: Specifications for pipes, fittings and the system EN ISO 472, Plastics – Vocabulary (ISO 472) EN ISO 1043-1, Plastics – Symbols and abbreviated terms – Part 1: Basic polymers and their special characteristics (ISO 1043-1) EN ISO 1133-1, Plastics - Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics – Part 1: Standard method (ISO 1133-1) EN ISO 1158, Plastics - Vinyl chloride homopolymers and copolymers - Determination of chlorine content (ISO 1158) EN ISO 1183-1, Plastics – Methods for determining the density of non-cellular plastics – Part 1: Immersion method, liquid pycnometer method and titration method (ISO 1183-1) EN ISO 1183-2, Plastics – Methods for determining the density of non-cellular plastics – Part 2: Density gradient column method (ISO 1183-2) EN ISO 2507-1, Thermoplastics pipes and fittings – Vicat softening temperature – Part 1: General test method (ISO 2507-1) EN ISO 3126, Plastics piping systems – Plastics components – Determination of dimensions (ISO 3126) EN ISO 3451-1, Plastics – Determination of ash – Part 1: General methods (ISO 3451-1:2019) EN ISO 3451-5, Plastics – Determination of ash – Part 5: Poly(vinyl chloride) (ISO 3451-5) EN ISO 11357-6, Plastics – Differential scanning calorimetry (DSC) – Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) (ISO 11357-6) EN ISO 13254, Thermoplastics piping systems for non-pressure applications – Test method for watertightness (ISO 13254) EN ISO 13257:2018, Thermoplastics piping systems for non-pressure applications – Test method for resistance to elevated temperature cycling (ISO 13257:2018) EN ISO 13259, Thermoplastics piping systems for underground non-pressure applications – Test method for leaktightness of elastomeric sealing ring type joints (ISO 13259) EN ISO 13263, Thermoplastics piping systems for non-pressure underground drainage and sewerage – Thermoplastics fittings - Test method for impact strength (ISO 13263) EN ISO 13264, Thermoplastics piping systems for non-pressure underground drainage and sewerage – Thermoplastics fittings – Test method for mechanical strength or flexibility of fabricated fittings (ISO 13264)
oSIST prEN 13598-1:2026 prEN 13598-1:2025 (E) EN ISO 13268, Thermoplastics piping systems for non-pressure underground drainage and sewerage – Thermoplastics shafts or risers for inspection chambers and manholes – Determination of ring stiffness
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN ISO 472, EN ISO 1043-1 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https://www.iso.org/obp/ui
- IEC Electropedia: available at https://www.electropedia.org/
3.1 application area code
code used in the marking of pipes and fittings to indicate the application area(s) for which they are intended, as follows:
U for the area more than 1 m from the building to which the buried piping system is connected; UD for application area U and the area under and within 1 m from the building where the pipes and the fittings are buried in ground and are connected to the soil and waste discharge system of the building.
3.2 drain
pipeline, usually underground, designed to carry wastewater from a source to a sewer [Source: EN 16323:2014, 2.2.3.1]
3.3 sewer
pipeline or other construction, usually underground, designed to carry wastewater from more than one source [Source: EN 16323:2014, 2.2.3.12]
3.4 wastewater
water composed of any combination of water discharged from domestic, industrial or commercial premises, surface run-off and accidentally any sewer infiltration water [Source: EN 16323:2014, 2.3.10.65, modified – sewage (deprecated) deleted]
3.4.1 foul wastewater
wastewater comprising domestic wastewater and/or industrial wastewater [Source: EN 16323:2014, 2.1.2.6]
3.4.2 surface water
water from precipitation, which has not seeped into the ground and is discharged to the drain or sewer system directly from the ground or from exterior building surfaces
oSIST prEN 13598-1:2026 prEN 13598-1:2025 (E) [Source: EN 16323:2014, 2.1.1.3, modified – Reference to Figure 1 deleted]
3.4.3 domestic wastewater
water polluted by the human life, including water discharged from kitchens, laundry rooms, lavatories, bathrooms, toilets and similar facilities [Source: EN 16323:2014, 2.1.2.3, modified – sewage (deprecated) deleted]
3.4.4 industrial wastewater
wastewater discharge resulting from any industrial or commercial activity [Source: EN 16323:2014, 2.1.2.7 modified – trade wastewater (deprecated) and trade effluent (deprecated) deleted]
3.5 private drain
discharge system which is not a part of the public drain or sewer
3.6 pedestrian area
area reserved for pedestrians and only occasionally open to vehicular traffic for delivery, cleaning purposes or in an emergency [Source: EN 124-1:2015, 3.1.27]
3.7 sealed access fitting
fitting that permits entry into the system for rodding or inspection and that has a sealed cover Note 1 to entry: Figure 1 shows examples of sealed access fittings, other designs are possible. Note 2 to entry: Sealed access fittings are typically buried to a depth of 2m or installed up to 6m when installed within a chamber
3.8 rodding point cover
fitting installed at ground level with a removable cover that permits the introduction of equipment for inspection and the clearance of blockages Note 1 to entry: Figure 2 shows examples of rodding point covers, other designs are possible.
3.9 rodding tee
fitting installed in a drain or sewers that connects to a rodding point at ground level that permits the introduction of equipment for the clearance of blockages, and also equipment for the inspection of the connecting pipe work in one or more directions Note 1 to entry: Figure 3 shows an example of a rodding tee, other designs are possible.
oSIST prEN 13598-1:2026 prEN 13598-1:2025 (E)
3.10 mechanical saddle
fitting that enables a branch connection to be made to buried drains and sewers of larger diameter by cutting a hole in the larger pipe and is retained in position by mechanical means Note 1 to entry: Figure 4 shows examples of mechanical saddles, other designs are possible. Note 2 to entry: Preferred nominal angles for mechanical saddle branches are 45° and 90°.
3.11 shallow chamber
fitting installed to a maximum depth of 2,0 m from ground level to the invert of the main flow channel that permits the introduction of equipment for the clearance of blockages, cleaning and inspection from surface level, but does not provide access for personnel and which terminates at ground level with a riser shaft of DN/ID 180 minimum and DN/ID of less than 800 Note 1 to entry: See also EN 476 for non-circular chambers.
Note 2 to entry: Figure 5a and Figure 5b show examples of shallow chambers. Other designs are possible.
3.12 shallow chamber base
bottom part of a shallow chamber, including integrally formed flow channels with benching as appropriate Note 1 to entry: In case of a one-piece shallow chamber, for testing purposes the base component ends at a distance of minimum 300 mm measured from the top of the main flow channel. Above 300 mm the section should be considered as a riser and tested accordingly.
Note 2 to entry: The benching is the transition between the formed flow channel and the inside wall of the base.
3.13 flow channel
open and accessible continuation of the sewer network in a manhole or inspection chamber to allow directional changes maintaining the hydraulic performance of a sewer system Note 1 to entry: The term flow profile is also used.
3.14 benching
sloped surface adjacent to the channel in a manhole or inspection chamber
3.15 invert
lowest point of the internal surface of the barrel of a pipe or channel at any cross section
3.16 shallow chamber riser
component which is connected onto a base and which defines the nominal size of the shallow chamber Note 1 to entry: The riser can be supplied either as one or more separate items, for site jointing to the base, or integrated with the base.
oSIST prEN 13598-1:2026 prEN 13598-1:2025 (E) Note 2 to entry: In case of a one-piece shallow chamber, for testing purposes the riser component starts at a distance of minimum 300 mm measured from the top of the main flow channel. Below 300 mm the section should be considered as a base and tested accordingly.
3.17 assembly
items collectively forming a shallow chamber or ancillary fitting Note 1 to entry: See typical examplesfor shallow chambers in Figure 5a and Figure 5b.
3.18 fabricated fitting
fittings produced from pipes and/or from injection-moulded fittings by thermoforming, adhesive joint or welding Note 1 to entry: Fabricated fittings need an additional fabrication step.
3.19 virgin material
plastics material in the form of pellets, granules, powder, floc, etc. that has not been subjected to use or processing other than that required for its initial manufacture Note 1 to entry: Does not contain any reworked plastics material and/or plastics recyclate. Note 2 to entry: Sometimes also referred to as “primary material” or “primary plastics feedstock” Note 3 to entry: It is understood that the addition of additives such as stabilizers and pigments is still resulting into a virgin (plastics) material.
[SOURCE: ISO 472:2013, 2.1231, modified – Note 1 to entry, Note 2 to entry and Note 3 to entry added] .
3.20 reworked material
plastics material from rejected unused products or trimmings capable of being reclaimed within the same process that generated it Note 1 to entry: Reworked material does not change the status of the feedstock. Note 2 to entry: This definition does not cover the conditions for the use of reworked material, which can be found in the applicable product standard.
Note 3 to entry: Previously referred to as “own reprocessed material”
3.21 pre-consumer material
plastics material diverted from the waste stream during a manufacturing process, excluding reworked (plastics) material Note 1 to entry: Previously referred to as “post-industrial material”. Note 2 to entry: Different categories of pre-consumer material may be considered in the applicable product standard.
[SOURCE: ISO 14021:2016, 7.8.1.1 modified – “plastics” added, text deleted after “rework” and 2 Notes to entry introduced]
oSIST prEN 13598-1:2026 prEN 13598-1:2025 (E)
3.22 post-consumer material
plastics material generated by households or by commercial, industrial and institutional facilities in their role as end-users of the product which can no longer be used for its intended purpose Note 1 to entry: This includes returns of material from the distribution chain. Note 2 to entry: Different categories of post-consumer material may be considered in the applicable product standard.
[SOURCE: ISO 14021:2016, 7.8.1.1 modified – “plastics” added, last sentence changed into Note 1 to entry and Note 2 to entry introduced]
3.23 recyclate
plastics material resulting from the recycling of pre-consumer and post-consumer plastics products Note 1 to entry: Also referred to as “secondary raw material” or “recycled plastics” or “regenerate”. Note 2 to entry: Recycling can be chemical, physical or mechanical. [SOURCE: ISO 472:2013, 2.1705, modified – Note 1 to entry and Note 2 to entry deleted, new Note 1 to entry and Note 2 to entry introduced and “plastic waste” changed into “pre-consumer and post-consumer plastics products”]
3.24 agreed specification
specification of the relevant material characteristics agreed between the supplier of the recylate and the pipe and/or fitting manufacturer Note 1 to entry: The agreed specification is often considered in the context of certification by a third party organization.
Figure 1 — Examples of sealed access fittings
oSIST prEN 13598-1:2026 prEN 13598-1:2025 (E)
Figure 2 — Examples of rodding point covers
Figure 3 — Example of a rodding tee
Figure 4 — Examples of mechanical saddles
oSIST prEN 13598-1:2026 prEN 13598-1:2025 (E)
Key a considered as riser b considered as base 1 inlet 2 outlet 3 invert 4 inside diameter 5 benching 6 main flow channel Figure 5a — Examples of a one-piece shallow chamber
Key a riser b base c connection 1 inlet 2 outlet 3 invert 4 inside diameter 5 benching 6 main flow channel Figure 5b — Example of shallow chamber with separate components
oSIST prEN 13598-1:2026 prEN 13598-1:2025 (E)
4 Symbols and abbreviations
4.1 Symbols
For the purposes of this document, the following symbols apply. A length of engagement d mean outside diameter em d nominal outside diameter n d mean inside diameter of socket sm e minimum wall thickness min e2 wall thickness of a socket e wall thickness in the groove area
L length of spigot
y determined value when tested H vertical deflection of the main channel diameter W horizontal deflection of the main channel diameter
oSIST prEN 13598-1:2026 prEN 13598-1:2025 (E)
4.2 Abbreviations
For the purposes of this document, the following abbreviations apply. DN nominal size DN/ID nominal size, inside diameter related DN/OD nominal size, outside diameter related DSC differential scanning calorimetry IR infrared MFR melt mass-flow rate NA not applicable OIT oxidation induction time PE polyethylene PP polypropylene PVC-U unplasticized poly(vinyl chloride) SN nominal ring stiffness
...