SIST EN 50625-2-2:2015
(Main)Collection, logistics & Treatment requirements for WEEE - Part 2-2: Treatment requirements for WEEE containing CRTs and flat panel displays
Collection, logistics & Treatment requirements for WEEE - Part 2-2: Treatment requirements for WEEE containing CRTs and flat panel displays
This European standard is applicable to the treatments of WEEE containing CRTs and flat panel
displays.
This European standard applies to the treatment of WEEE containing CRTs and flat panel displays
until end-of-waste status is fulfilled, or fractions are recycled, recovered, or disposed of.
This European standard addresses all operators involved in the treatment including related handling,
sorting, and storage.
Sammlung, Logistik und Behandlung von Elektro- und Elektronik-Altgeräten (WEEE) - Teil 2-2: Anforderungen an die Behandlung von WEEE, die Röhrenbildschirme und Flachbildschirmmodule enthalten
Exigences de collecte, logistique et traitement pour les déchets d’équipements électriques et électroniques (DEEE) - Partie 2-2: Exigences de traitement pour les DEEE contenant des tubes électroniques et des écrans plats
Zahteve za zbiranje, logistiko in obdelavo odpadne električne in elektronske opreme (WEEE) - 2-2. del: Zahteve za obdelavo opreme, ki vsebuje CRT in ravne ekrane
Ta evropski standard se uporablja za obdelavo odpadne električne in elektronske opreme (WEEE), ki vsebuje ekrane CRT in ravne ekrane.
Ta evropski standard velja za obdelavo odpadne električne in elektronske opreme, ki vsebuje ekrane CRT in ravne ekrane, do prenehanja statusa odpadka.
Ta evropski standard zajema vse izvajalce obdelave, vključno s tistimi, ki zajemajo povezano ravnanje, razvrščanje in shranjevanje.
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 50625-2-2:2015
01-september-2015
=DKWHYH]D]ELUDQMHORJLVWLNRLQREGHODYRRGSDGQHHOHNWULþQHLQHOHNWURQVNH
RSUHPH:(((GHO=DKWHYH]DREGHODYRRSUHPHNLYVHEXMH&57LQUDYQH
HNUDQH
Collection, logistics & Treatment requirements for WEEE - Part 2-2: Treatment
requirements for WEEE containing CRTs and flat panel displays
Sammlung, Logistik und Behandlung von Elektro- und Elektronik-Altgeräten (WEEE) -
Teil 2-2: Anforderungen an die Behandlung von WEEE, die Röhrenbildschirme und
Flachbildschirmmodule enthalten
Exigences de collecte, logistique et traitement pour les déchets d’équipements
électriques et électroniques (DEEE) - Partie 2-2: Exigences de traitement pour les DEEE
contenant des tubes électroniques et des écrans plats
Ta slovenski standard je istoveten z: EN 50625-2-2:2015
ICS:
13.030.99 Drugi standardi v zvezi z Other standards related to
odpadki wastes
31.120 Elektronske prikazovalne Electronic display devices
naprave
SIST EN 50625-2-2:2015 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 50625-2-2:2015
---------------------- Page: 2 ----------------------
SIST EN 50625-2-2:2015
EUROPEAN STANDARD EN 50625-2-2
NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2015
ICS 13.030.99, 31.120
English Version
Collection, logistics & Treatment requirements for WEEE - Part
2-2: Treatment requirements for WEEE containing CRTs and flat
panel displays
Exigences de collecte, logistique et traitement pour les
déchets d'équipements électriques et électroniques (DEEE)
- Partie 2-2: Exigences de traitement pour les DEEE
contenant des tubes électroniques et des écrans plats
This European Standard was approved by CENELEC on 2015-04-13. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 50625-2-2:2015 E
---------------------- Page: 3 ----------------------
SIST EN 50625-2-2:2015
EN 50625-2-2:2015 - 2 -
Contents
Foreword . 3
Introduction . 4
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 5
4 Administrative and organisational requirements . 6
4.3 Training . 6
4.3.1 CRT equipment . 6
5 Technical requirements . 6
5.1 General . 6
5.1.1 CRT Equipment . 6
5.1.2 FPD-equipment . 7
5.2 Receiving of WEEE at treatment facility . 7
5.3 Handling of WEEE. 7
5.3.1 CRT equipment and FPD equipment . 7
5.4 Storage of WEEE prior to treatment . 7
5.5 De-pollution . 8
5.5.1 CRT equipment . 8
5.5.2 FPD-equipment . 8
5.6 De-pollution monitoring . 8
5.6.1 CRT equipment . 8
5.6.2 FPD-equipment . 9
5.7 Treatment of non de-polluted WEEE and fractions . 9
5.8 Storage of fractions . 9
5.9 Recycling and recovery targets . 9
5.10 Recovery and disposal of fractions . 9
5.10.1 CRT -equipment . 9
5.10.2 FPD-equipment . 9
5.11 Occupational health monitoring (Additional clause) . 9
6 Documentation . 10
Annex A (normative) De-pollution . 11
Annex B (normative) De-pollution monitoring . 12
Annex C (normative) Determination of recycling and recovery rates . 13
Annex D (normative) Requirements concerning processing of a batch . 14
Annex E (informative) . 15
Annex F (informative) Documentation for downstream monitoring and establishment of recycling and
recovery rates . 16
Annex AA (normative) Frequency table of residual mercury concentration checks at FPD treatment . 17
Annex ZZ (informative) Coverage of Requirements of Commission Directive (EC) 2012/19/EU . 18
Bibliography . 19
---------------------- Page: 4 ----------------------
SIST EN 50625-2-2:2015
- 3 - EN 50625-2-2:2015
Foreword
This document (EN 50625-2-2:2015) has been prepared by CLC/TC 111X “Environment”.
The following dates are fixed:
• latest date by which this document has to be (dop) 2016-04-13
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards (dow) 2018-04-13
conflicting with this document have to
be withdrawn
This part 2 is to be used in conjunction with EN 50625-1:2014.
NOTE 1 When “Part 1” is mentioned in this standard, it refers to EN 50625–1:2014.
This Part 2 supplements or modifies the corresponding clauses in EN 50625-1, so as to convert that
publication into the European Standard: Treatment requirements for WEEE containing CRTs and Flat
Panel Displays
When a particular subclause of Part 1 is not mentioned in this Part 2, that subclause applies as far as
is reasonable. When this standard states “addition”, “modification” or “replacement”, the relevant text
in Part 1 is to be adapted accordingly.
NOTE 2 The following numbering system is used:
– subclauses, tables and figures that are numbered starting from 101 are additional to those in Part 1;
– additional annexes are lettered AA, BB, etc.
NOTE 3 The following print types are used:
– requirements: in roman type;
– changes compared to part 1: in italic type
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
This document has been prepared under mandate M/518 given to CENELEC by the European
Commission and the European Free Trade Association, and supports requirements of Directive
2012/19/EU (WEEE).
For the relationship with the EU Directive see informative Annex ZZ, which is an integral part of this
document.
---------------------- Page: 5 ----------------------
SIST EN 50625-2-2:2015
EN 50625-2-2:2015 - 4 -
Introduction
This clause of Part 1 is replaced by the following:
This European Standard aims to assist organisations in:
− achieving effective and efficient treatment and disposal of WEEE containing CRTs and flat panel
displays in order to prevent pollution and minimize emissions;
− promoting increased material recycling;
− promoting high quality recovery operations;
− preventing inappropriate disposal of Waste Electrical and Electronic Equipment (WEEE) containing
CRTs and Flat Panel Displays and fractions thereof;
− assuring protection of human health and safety, and the environment;
− preventing shipments and, or consignments of WEEE containing CRTs and flat panel displays to
operators whose operations fail to comply with this normative document or a comparable set of
requirements.
This European Standard supports the objectives of the Community's environment policy.
This aims to preserve, protect and improve the quality of the environment, protect human health and
utilize natural resources prudently and rationally. That policy is based on the precautionary principle
and the maxims that preventive action to minimize environmental damage should, where possible, be
rectified at source and the polluter should pay.
This European Standard contains requirements applicable to the treatment of WEEE containg CRTs
and flat panel displays and is a Part 2 of EN 50625-1, Collection, logistics and Treatment requirements
for WEEE - Part 1:General treatment requirements. Additionally, this standard will be supported by a
technical report that will provide a more detailed comparison between normative treatment
requirements derived directly from the legal text of Directive 2012/19/EC, especially Annex VII, and
between informative treatment requirements going beyond the strict requirements of Directive
2012/19/EC.
This European Standard has been prepared in order to support European legislation and so uses
some of the terms defined in European law. In order to ensure that the definitions used in this
standard are identical to those defined by law these terms are identified as 'void', indicating that this
standard does not contain a definition, and a 'Note to entry' that identifies which law contains the legal
definition and the term as defined in that law.
---------------------- Page: 6 ----------------------
SIST EN 50625-2-2:2015
- 5 - EN 50625-2-2:2015
1 Scope
This clause of Part 1 is replaced by the following:
This European standard is applicable to the treatments of WEEE containing CRTs and flat panel
displays.
This European standard applies to the treatment of WEEE containing CRTs and flat panel displays
until end-of-waste status is fulfilled, or fractions are recycled, recovered, or disposed of.
This European standard addresses all operators involved in the treatment including related handling,
sorting, and storage.
2 Normative references
This clause of Part 1 is applicable.
3 Terms and definitions
This clause of Part 1 is applicable with the following addition.
3.101
fluorescent coatings
coatings laid on the inner side of the panel glass of a CRT which may contain a wide range of metals,
rare-metals (e.g. europium and yttrium), and heavy metals (e.g cadmium)
3.102
CRT glass
all types of glass originating from the treatment of CRTs, either as a separate fraction or a mixed
fraction, as illustrated in Figure 1:
Figure 1 - Types of glass in a CRT
3.102.1
panel glass
glass from front part of a CRT
Note 1 to entry: See Figure 1 symbol a
Note 2 to entry: Panel glass contains high content of barium oxide and strontium oxide
Note 3 to entry: Panel Glass does not include frit glass
Note 4 to entry: Panel glass and funnel glass are glued toghther by frit glass
---------------------- Page: 7 ----------------------
SIST EN 50625-2-2:2015
EN 50625-2-2:2015 - 6 -
3.102.2
funnel glass
glass from back part of a CRT
Note 1 to entry: See Figure 1 symbol c
Note 2 to entry: Funnel glass contains high content of lead oxide
3.102.3
frit
...
Questions, Comments and Discussion