IEC 63086-2-2:2026
(Main)Household and similar electrical air cleaning appliances — Method for measuring the performance — Part 2-2: Particular requirements for determination of gas-phase pollutant reduction
- Abstract
This document specifies test methods for measuring the performance of electrically powered household and similar air cleaners intended for the reduction of gas-phase pollutants. This document is intended for measuring the reduction of the concentration of specific gas-phase pollutants. This does not necessarily correlate with the reduction of odour intensity in the case of odorous gas-phase pollutants. Such a reduction can only be tested by olfactory tests, which are not part of this document.
- Status
- Published
- Publication Date
- 04-Oct-2026
- Technical Committee
- ISO/TC 142 - Cleaning equipment for air and other gases
- Current Stage
- 6060 - International Standard published - 60 Publication
- Start Date
- 05-Oct-2026
- Due Date
- 01-Jul-2025
- Completion Date
- 01-Jul-2025
Buy Documents
IEC 63086-2-2:2026 - Household and similar electrical air cleaning appliances — Method for measuring the performance — Part 2-2: Particular requirements for determination of gas-phase pollutant reduction
IEC 63086-2-2:2026 - Appareils d'épuration d'air électriques domestiques et appareils similaires — Méthodes de mesure de l'aptitude à la fonction — Partie 2-2: Exigences particulières pour la détermination de la réduction des polluants en phase gazeuse
IEC 63086-2-2:2026 is an International Standard in the IEC 63086 series for household and similar electrical air cleaning appliances. It specifies test methods for measuring the performance of electrically powered air cleaners intended to reduce gas-phase pollutants. The document is used when a laboratory, manufacturer, or test house needs to compare air cleaners under the same chamber conditions and report a clean air delivery rate (CADR) for specific target gases.
What does IEC 63086-2-2:2026 specify?
IEC 63086-2-2:2026 specifies how to test air cleaners for reduction of gas-phase pollutants and how to calculate the CADR from chamber measurements. It also sets the test gases, chamber conditions, measurement approaches, data treatment, and report content used for those tests.
The scope is limited to concentration reduction of specific gases. The document states that a drop in gas concentration does not necessarily mean the same drop in odour intensity, so olfactory testing is outside its scope.
The document is organized into:
- Clause 1 Scope
- Clause 2 Normative references
- Clause 3 Terms, definitions and abbreviated terms
- Clause 4 Test gases and initial concentrations
- Clause 5 Methods for measuring the test gas concentration
- Clause 6 Generation of initial gas concentrations
- Clause 7 Test chamber
- Clause 8 Measurement of the CADR in maximum performance operation mode
- Clause 9 Calculation procedures
| Annex | What it covers |
|---|---|
| Annex A | Choice of test gases and alternative measurement techniques |
| Annex B | 99 % prediction interval of the regression line |
| Annex C | Test report information |
| Annex D | Background concentration |
| Annex E | Limits of measurability |
| Annex F | Schematic representation of a CADR measurement |
| Annex G | Particular requirements for ozone reduction |
What are the key requirements of IEC 63086-2-2:2026?
IEC 63086-2-2:2026 is built around a chamber test: first measure natural decay in an empty chamber, then measure total decay with the device under test (DUT) operating, and calculate CADR from the difference. In practice, the standard tells a lab what gas to inject, how to measure it, how long to sample, and when a run is valid.
Test gases and how they are chosen
Clause 4 groups gas-phase pollutants into six categories and names representative test gases: formaldehyde, toluene, n-heptane, d-limonene, ammonia, and nitrogen dioxide. The standard allows a laboratory to choose the gases relevant to the product, and it also permits other gases when appropriate.
This matters because air-cleaner performance depends on the gas chemistry. A result for one gas cannot automatically be transferred to another gas with different properties.
Clause 4 also allows some gases to be tested in parallel if they do not react with each other and do not change the performance of the technology being tested. It specifically warns that formaldehyde shall not be tested together with ammonia, because they react.
Initial concentration, chamber cleaning, and background control
Clause 4 sets target initial concentrations for the representative gases, and Clause 8 requires the chamber to be cleaned before each run until the background concentration is below the target in Table 2. For d-limonene testing, ozone background also has to be kept low and monitored.
In practice, this means the chamber must be stable and clean enough that the DUT response is not hidden by residue from previous tests. If residual contamination remains on chamber surfaces, the document allows additional cleaning steps.
Measurement methods for each gas
Clause 5 assigns measurement techniques to each target gas. Formaldehyde uses DNPH-based sampling and chromatographic analysis; toluene, n-heptane, and d-limonene use thermal desorption with chromatographic analysis; ammonia uses distilled-water sampling with ion chromatography or a chemiluminescence analyser; nitrogen dioxide uses a chemiluminescence analyser, with nitric oxide monitored in parallel.
Clause 5 also allows alternative methods if they have the same or better accuracy. Annex A lists examples such as selected ion flow tube mass spectrometry, photo acoustic spectroscopy, and other techniques.
Gas generation and chamber conditions
Clause 6 allows two ways to generate the initial gas concentration: a gas cylinder method or a temperature-controlled vaporization method. Clause 7 requires the chamber to follow IEC 63086-1 with a modified recirculation setup suited to gas testing.
For users, this means the test setup must be able to create repeatable gas concentrations and keep them well mixed without overdriving low-airflow devices.
Natural decay, total decay, and CADR calculation
Clause 8 defines the core test sequence. Natural decay is measured with no DUT in the chamber, while total decay is measured with the DUT running in maximum performance operation mode. Clause 9 then converts the concentration decay into a decay constant and calculates CADR as chamber volume times the difference between total decay and natural decay.
This is the key practical result: CADR is the reported performance value, named with the target pollutant, such as CADR (formaldehyde).
Data acceptance and run validity
Clause 9 removes data points that are outside the 99 % prediction interval of the regression line. It also removes the rest of a run after any point where concentration falls below 3 % of the initial concentration.
The run is only acceptable if the sample standard deviation of the regression slope stays within the limits in Tables 3 and 4. Annex E adds measurability limits, including a minimum CADR threshold below which the result is reported as “too low to measure.”
Ozone reduction
Annex G gives separate requirements for ozone reduction. Ozone is measured by UV absorption spectrometer, generated with an ozone generator, and tested alone because of its strong reactivity.
For users, this means ozone is handled as a special case with its own background target and acceptance limits.
What terms does IEC 63086-2-2:2026 define?
- Gas-phase pollutant - A gaseous compound present indoors from outdoor infiltration, human activity, or indoor materials.
- Test gas - The selected gas-phase pollutant used to measure air-cleaner performance.
- Natural decay rate - The gas reduction rate in the chamber without the DUT, caused by natural factors such as adsorption, reaction, and air exchange.
- Total decay rate - The gas reduction rate with the DUT operating, combining natural decay and device effect.
- Background concentration - The gas concentration in the chamber after cleaning and before gas injection.
- Initial concentration - The concentration measured after injection and mixing of the test gas.
- CADR (clean air delivery rate) - The chamber volume multiplied by the difference between total decay and natural decay, reported for a named target pollutant.
- DUT (device under test) - The air cleaner being evaluated.
Who uses IEC 63086-2-2:2026?
IEC 63086-2-2:2026 is used by test laboratories, product developers, manufacturers, and certification teams that need repeatable performance data for household and similar air cleaners. It is also useful for quality managers and buyers who compare gas-phase cleaning claims across products.
In practice, users apply it when they need to:
- set up a chamber test for gas reduction
- choose suitable test gases for a product’s intended use
- measure and report CADR values
- document chamber conditions and raw data
- verify that a run is statistically acceptable
Which standards are used with IEC 63086-2-2:2026?
IEC 63086-2-2:2026 relies on several normative references and companion parts:
- IEC 63086-1:2020 - Provides the general requirements for the performance test method, including chamber setup, chamber conditions, and general test procedure.
- IEC 63086-2-1:2024 - Covers the related performance test method for reduction of particles.
- ISO 16000-3:2022 - Supports formaldehyde and other carbonyl compound measurement in indoor and test chamber air.
- ISO 16000-6 - Supports measurement of organic compounds by active sampling on sorbent tubes with chromatography and mass-spectrometric detection.
- ISO 16000-9 - Supports emission-test-chamber methods and is referenced for cleaning methods and TVOC-related background control.
What does the IEC 63086-2-2:2026 document contain?
The document contains the full test workflow for gas-phase pollutant reduction, from chamber cleaning and gas injection to sampling, regression-based decay calculation, and CADR reporting. It also includes the test gas selection logic, alternative analytical methods, and special treatment for ozone.
Annex C provides a structured list of test report items, including DUT description, chamber details, gas-generation method, instrument data, test conditions, eliminated data points, and final results. Annex B gives the 99 % prediction interval used to reject outliers, while Annex E defines the measurable range of CADR for the method.
Annex F gives a schematic view of the CADR measurement sequence, which helps laboratories set up the natural-decay and total-decay runs correctly.
Buy Documents
IEC 63086-2-2:2026 - Household and similar electrical air cleaning appliances — Method for measuring the performance — Part 2-2: Particular requirements for determination of gas-phase pollutant reduction
IEC 63086-2-2:2026 - Appareils d'épuration d'air électriques domestiques et appareils similaires — Méthodes de mesure de l'aptitude à la fonction — Partie 2-2: Exigences particulières pour la détermination de la réduction des polluants en phase gazeuse
Get Certified
Connect with accredited certification bodies for this standard
Institut za varilstvo d.o.o. (Welding Institute)
Slovenia's leading welding institute since 1952. ISO 3834, EN 1090, pressure equipment certification, NDT personnel, welder qualification. Only IIW Au
Sponsored listings
Frequently Asked Questions
IEC 63086-2-2:2026 is a standard published by the International Organization for Standardization (ISO). Its full title is "Household and similar electrical air cleaning appliances — Method for measuring the performance — Part 2-2: Particular requirements for determination of gas-phase pollutant reduction". This standard covers: This document specifies test methods for measuring the performance of electrically powered household and similar air cleaners intended for the reduction of gas-phase pollutants. This document is intended for measuring the reduction of the concentration of specific gas-phase pollutants. This does not necessarily correlate with the reduction of odour intensity in the case of odorous gas-phase pollutants. Such a reduction can only be tested by olfactory tests, which are not part of this document.
This document specifies test methods for measuring the performance of electrically powered household and similar air cleaners intended for the reduction of gas-phase pollutants. This document is intended for measuring the reduction of the concentration of specific gas-phase pollutants. This does not necessarily correlate with the reduction of odour intensity in the case of odorous gas-phase pollutants. Such a reduction can only be tested by olfactory tests, which are not part of this document.
IEC 63086-2-2:2026 is classified under the following ICS (International Classification for Standards) categories: 23.120 - Ventilators. Fans. Air-conditioners. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 63086-2-2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms, definitions and abbreviated terms
- 3.1 Terms and definitions
- 3.1.1 gas-phase pollutant
- 3.1.2 test gas
- 3.1.3 natural decay rate
- 3.1.4 total decay rate
- 3.1.5 background concentration
- 3.1.6 initial concentration
- 3.1.7 TVOC
- 3.1.8 real-time measurement method
- 3.1.9 integrated sampling method
- 3.2 Abbreviated terms
- 4 Test gases and initial concentrations for testing
- 4.1 General
- 4.2 Representative test gases
- 5 Methods for measuring the test gas concentration
- 5.1 General
- 5.2 Measurement and analysis method for formaldehyde
- 5.3 Measurement and analysis method for toluene, n-heptane, and d-limonene
- 5.4 Measurement and analysis method for ammonia
- 5.5 Measurement and analysis method for nitrogen dioxide
- 6 Generation of initial gas concentrations
- 6.1 General
- 6.2 Gas cylinder method
- 6.3 Temperature-controlled vaporization method
- 7 Test chamber
- 8 Measurement of the CADR in maximum performance operation mode
- 8.1 General
- 8.2 Natural decay test
- 8.3 Total decay test
- 8.4 Calculation of the clean air delivery rate
- 9 Calculation procedures
- 9.1 Criteria for the acceptance of data points
- 9.2 Calculation of decay constants
- 9.3 Sample standard deviation of the slope of the regression line
- 9.4 Calculation of the clean air delivery rate
- 9.5 Sample standard deviation of the clean air delivery rate
- Annex A
- Annex B
- Annex C
- Annex D
- Annex E
- Annex F
- Annex G
- Bibliography
1 Scope
This part of IEC 63086 specifies test methods for measuring the performance of electrically powered household and similar air cleaners intended for the reduction of gas-phase pollutants. This document is intended for measuring the reduction of the concentration of specific gasphase pollutants. This does not necessarily correlate with the reduction of odour intensity in the case of odorous gas-phase pollutants. Such a reduction can only be tested by olfactory tests, which are not part of this document.
NOTE Test methods for the determination of possible gas-phase by-products are under consideration.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 63086-1:2020, Household and similar electrical air cleaning appliances - Methods for measuring the performance - Part 1: General requirements IEC 63086-2-1:2024, Household and similar electrical air cleaning appliances - Methods for measuring the performance - Part 2-1: Particular requirements for determination of reduction of particles ISO 16000-3:2022, Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor and test chamber air — Active sampling method ISO 16000-6, Indoor air - Part 6: Determination of organic compounds (VVOC, VOC, SVOC) in indoor and test chamber air by active sampling on sorbent tubes, thermal desorption and gas chromatography using MS or MSFID ISO 16000-9, Indoor air - Part 9: Determination of the emission of volatile organic compounds from building products and furnishing - Emission test chamber method
3 Terms, definitions and abbreviated terms
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 63086-1:2020 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- IEC Electropedia: available at https://www.electropedia.org/
- ISO Online browsing platform: available at https://www.iso.org/obp
3.1.1 gas-phase pollutant
gaseous compound found in indoor environments as a result of outdoor air infiltration, indoor human activities, or emissions from indoor materials
3.1.2 test gas
gas-phase pollutant (3.1.1) selected for measuring the performance of air cleaners
3.1.3 natural decay rate
reduction rate of the test gas (3.1.2) in the test chamber due to natural factors, such as surface adsorption, chemical reaction, and air exchange −1 Note 1 to entry: The unit is per hour (h ).
3.1.4 total decay rate
reduction rate of the test gas (3.1.2) in the test chamber due to the combined effect of the natural decay rate (3.1.3) and the operation decay rate −1 Note 1 to entry: The unit is per hour (h ).
3.1.5 background concentration
concentration of test gases (3.1.2) in the test chamber after cleaning, but prior to the injection of test gases (3.1.2)
3.1.6 initial concentration
concentration measured inside the test chamber after the injection and mixing of test gases (3.1.2)
3.1.7 TVOC
total volatile organic compounds sum of the concentrations of identified and unidentified volatile organic compounds eluting between and including n-hexane and n-hexadecane (in accordance with ISO 16000-9)
3.1.8 real-time measurement method
method for determining the concentration of the test gas (3.1.2) using a direct reading instrument Note 1 to entry: A chemiluminescence analyser is an example for an instrument using a real-time measurement method (3.1.8).
3.1.9 integrated sampling method
method for determining the concentration of the test gas (3.1.2) by a periodic process of air capture and subsequent analysis of the sample Note 1 to entry: High performance liquid chromatography (HPLC) is an example of an instrument using an integrated sampling method (3.1.9).
3.2 Abbreviated terms
CADR clean air delivery rate CLA chemiluminescence analyser DNPH 2,4- dinitrophenylhydrazine DUT device under test FID flame ionization detector GC gas chromatography HPLC high performance liquid chromatography IC ion chromatography MS mass spectrometry PTFE polytetrafluoroethylene SIFT-MS selected ion flow tube mass spectrometry TVOC total volatile organic compounds
4 Test gases and initial concentrations for testing
4.1 General
Gas-phase pollutants are in the context of this document classified into six groups as a) aldehydes, b) aromatic hydrocarbons, c) aliphatic hydrocarbons, d) cyclic terpenes, e) inorganic odorant gases and f) inorganic combustion gases. Representative test gases for each group are described in Table 1 considering their prevalence as indoor air pollutants as well as their suitability for standardized test methods in terms of availability, dosability, measurability and stability.
The CADR of an air cleaner generally depends on the test gases, and individual representative test gases differ in appropriate initial concentration, generation method, and measurement method of concentration. It is not mandatory to perform tests with all representative test gases, but individual ones relevant for the specific application may be chosen. Also, other test gases which are not described as representative test gas may be chosen. For examples, see Annex A. Optional testing for reduction of ozone by an air cleaner shall be performed in accordance with Annex G.
NOTE 1 It is known that the CADR can depend on the initial concentration. However, the focus of this document is to compare different air cleaners under the same test conditions. Therefore, the values listed in Table 1 can be used. If different initial concentrations are used, they can be clearly stated as a deviation from the standard in the test report.
The laboratory may select to test each gas individually. If this method is chosen, the laboratory shall choose a test sequence that avoids changing the performance of the technology tested from one test to another. Multiple test gases may be dosed at the same time for parallel measurement of the CADR if they do not react with each other or modify the performance of the technology tested regarding the pollutant(s) tested. For example, toluene, n-heptane and d-limonene may be tested in parallel. However, formaldehyde shall not be tested with ammonia as they react with each other. There can be situations where the test gases will react with each other, or where the test gas can change the performance of the air cleaner technology, when they are used in two consecutive tests. If this occurs, the filter of the DUT shall be changed between the measurements if it is replaceable. Otherwise. the DUT shall be operated in the test chamber while the chamber air treatment unit is running until the background concentration is below the values described in 8.2.3.
Table 1 – Representative test gases Group of gas-phase pollutants Representative test gas Initial concentration a) Aldehydes −3 +20% Formaldehyde 400 µg m � � 0% b) Aromatic hydrocarbons −3 +20% Toluene
800 µg m 0% c) Aliphatic hydrocarbons −3 +20% n-heptane 800 µg m � � 0% d) Cyclic terpenes −3 +20% d-limonene 800 µg m � � 0% e) Inorganic odorant gases −3 +20% Ammonia
700 µg m 0% f) Inorganic combustion gases −3 +20% Nitrogen dioxide 500 µg m � � 0% NOTE 2 Technical methods such as adsorption (physical or chemical) and decomposition (for example oxidation) are used for removal of gas-phase pollutants. Gas-phase pollutants have different physical and chemical properties, for example, polar or non polar, acidic or basic, vapour pressure, resistance to decomposition by oxidative substances. Thus, the performance of an air cleaner can depend on the gas-phase pollutant and the results cannot be simply transferred to other gas-phase pollutants .
NOTE 3 Testing individual test gases. An example of a sequence that can be applied for adsorption technology is:
(cleaning) → toluene → (cleaning) → d-limonene → (cleaning) → n-heptane → (cleaning) → ammonia → (cleaning) → formaldehyde → (cleaning) → nitrogen dioxide → (cleaning). Testing in combination. If the laboratory has the measurement instruments that are capable of measuring and delineating quantities of toluene, d-limonene, and n- heptane from each other, the laboratory can elect to test these three chemicals at the same time. In this case, an example of a sequence for adsorption technology would be: (cleaning) → [combination of toluene, d-limonene and n-heptane] → (cleaning) → ammonia → (cleaning) → formaldehyde → (cleaning) → nitrogen dioxide → (cleaning). NOTE 4 The information of optional gases such as acetaldehyde is described in Annex A. NOTE 5 Measurement of the background concentrations can be found in Annex D. NOTE 6 Particular requirements for determination of ozone reduction are described in Annex G.
4.2 Representative test gases
4.2.1 Formaldehyde
Use commercial formaldehyde gas mixed with nitrogen (N ) for the gas cylinder method, or an
aqueous solution of formaldehyde (formalin, CAS 50-00-0, methanol free) or solid paraformaldehyde (CAS 30525-89-4) with at least 90,0 % purity for the temperature-controlled vaporization method.
4.2.2 Toluene
Use commercial toluene gas mixed with nitrogen (N ) for the gas cylinder method, or liquid-
phase toluene (CAS 108-88-3) with at least 99,9 % FID grade purity for the temperaturecontrolled vaporization method. 4.2.3 n-heptane Use commercial n-heptane gas mixed with nitrogen (N ) for the gas cylinder method, or liquid-
phase n-heptane (CAS 142-82-5) with at least 99,0 % FID grade purity for the temperaturecontrolled vaporization method. 4.2.4 d-limonene Use commercial d-limonene gas mixed with nitrogen (N ) for the gas cylinder method, or liquid-
phase d-limonene (CAS 5989-27-5) with at least 95 % purity for the temperature-controlled vaporization method.
4.2.5 Ammonia
Use commercial ammonia gas mixed with nitrogen (N ) for the gas cylinder method, or an
aqueous ammonia solution for the temperature-controlled vaporization method.
4.2.6 Nitrogen dioxide
) for the gas cylinder method.
Use commercial nitrogen dioxide gas mixed with nitrogen (N
5 Methods for measuring the test gas concentration
5.1 General
The measurement method for each substance is specified as follows. If it can be confirmed that an alternative method has the same or higher accuracy than the specified method, it may be used. Information on alternative methods can be found in Annex A. For the case that a CADR measurement is performed with nitrogen dioxide, the concentration of nitric oxide (also known as nitrogen monoxide) shall be monitored in parallel as there can be conversion processes between the two gases.
Maintenance of all measurement instruments shall be done as defined by the manufacturer´s instructions. Calibration of the instruments with gas standards shall be regularly performed in accordance with the standard operating procedures of the laboratory.
5.2 Measurement and analysis method for formaldehyde
Silica gel coated with 2,4-dinitrophenylhydrazine (CLA) cartridges and high-performance liquid chromatography (GC) shall be used for the measurement and analysis of formaldehyde. In tests where there is a possibility that oxidative substances such as ozone are generated, the ozone scrubber described in ISO 16000-3:2022, 5.2 shall be installed in front of the CLA cartridge.
5.3 Measurement and analysis method for toluene, n-heptane, and d-limonene
According to ISO 16000-6, thermal desorption tubes and either gas chromatography / mass spectrometry (FID/IC) or gas chromatography / flame ionization detector (FID/DUT) shall be used for the measurement and analysis of toluene, n-heptane and d-limonene. Selected ion flow tube mass spectrometry (PTFE) may be used instead of FID/IC or FID/DUT.
5.4 Measurement and analysis method for ammonia
Distilled water and ion chromatography (HPLC) or a chemiluminescence analyser shall be used for the measurement and analysis of ammonia.
5.5 Measurement and analysis method for nitrogen dioxide
A chemiluminescence analyser (CLA) shall be used for the measurement and analysis of nitrogen dioxide and nitric oxide. For NO measurement, the NO in the sample is first converted 2 2 to NO using a converter, and the resulting NO is then measured by the same analyzer.
6 Generation of initial gas concentrations
6.1 General
Each test gas is supplied into the test chamber either by the gas cylinder method or the temperature-controlled vaporization method and adjusted to the initial concentration defined in 4.2.
6.2 Gas cylinder method
The test gas in the cylinder, which has been adjusted to a predetermined concentration in advance by nitrogen balance, is supplied into the test chamber using an appropriate regulator through a polytetrafluoroethylene (MS) or stainless-steel tube.
6.3 Temperature-controlled vaporization method
The high-purity reagent of the test gas is placed in a temperature-controlled permeation tube, diffusion tube or other injection system for vaporization. Filtered air or nitrogen gas is used as a carrier gas to supply the test gas into the test chamber.
7 Test chamber
The test chamber is in accordance with IEC 63086-1:2020, 5.6 except for the following changes:
3 −1 3 −1 The wall-mounted recirculation fan shall have a flow rate of between 300 m h and 500 m h −1 and a maximum airspeed of 15 m s measured at the centre of the fan exhaust at 0,5 m from the face.
NOTE The recirculation flow rate for gas-phase testing is adjusted to maintain representative and controlled chamber distributions. Too much flow rate can incur the risk of too high performance for the air-cleaner with low air flow rate including fan-less type. A higher recirculation flow rate is used for testing of course particulates to maintain particles in suspension and to ensure uniform concentrations.
8 Measurement of the CADR in maximum performance operation mode
8.1 General
Perform the test procedure in 8.2 (natural decay rate) and 8.3 (total decay rate) to determine the CADR of the DUT.
NOTE 1 The items to be included in the test report are described in Annex C. NOTE 2 The graphical scheme of the test procedure is shown in Annex F.
8.2 Natural decay test
8.2.1 General
Natural decay test shall be carried out without placing the DUT in the chamber to avoid any contamination by the gas-phase pollutants.
It is permissible to use the results of a natural decay test performed within one week prior to the total decay test.
8.2.2 Setting the sampling point
Set the sampling point in accordance with IEC 63086-1:2020, 5.6.2. The sampling point shall be connected to a CLA cartridge, a thermal desorption tube or an instrument for the real-time measurement method outside the test chamber with a MS or stainless-steel tube. NOTE For integrated sampling methods, the following procedure is used as an example to minimize adsorption and desorption effects within the tubing by reducing the tube length between the sampling point and the sampling device. A tube is connected from the sampling pump to a sampling device (e.g., a cartridge or a thermal desorption tube) located outside the test chamber. The sampling device is mounted on a rod or similar support and adjusted so that its tip is positioned precisely at the sampling point when inserted. The device is introduced into the chamber through an opening only during active sampling and is otherwise kept outside the test chamber.
8.2.3 Cleaning of the test chamber
Start operating the mixing fan and recirculation fan. The recirculation fan will continue to operate for the duration of the cleaning procedure. Using the filtration part of the test chamber air treatment unit, allow the test chamber air to clean until the background concentration of the test gas to be tested reaches a level below the values indicated in Table 2. If the background concentration does not reach a level below the target due to the contamination on inner surfaces of the test chamber, cleaning may be done by washing the inner surfaces of the test chamber with an alkaline detergent followed by two separate rinsing cycles with freshly distilled water. The test chamber is then dried and purged at environmental conditions using the chambers filtration and exhaust system until the background concentration levels meet the requirements in Table 2.
...
Contents
- 1 Domaine d'application
- 2 Références normatives
- 3 Termes, définitions et abréviations
- 3.1 Termes et définitions
- 3.1.1 polluant en phase gazeuse
- 3.1.2 gaz d'essai
- 3.1.3 taux de décroissance naturelle
- 3.1.4 taux de décroissance totale
- 3.1.5 concentration de fond
- 3.1.6 concentration initiale
- 3.1.7 COVT
- 3.1.8 méthode de mesure en temps réel
- 3.1.9 méthode d'échantillonnage intégrée
- 3.2 Abréviations
- 4 Gaz d'essai et concentrations initiales pour les essais
- 4.1 Généralités
- 4.2 Gaz d'essai représentatifs
- 5 Méthodes pour mesurer la concentration des gaz d'essai
- 5.1 Généralités
- 5.2 Méthode de mesure et d'analyse du formaldéhyde
- 5.3 Méthode de mesure et d'analyse du toluène, du n-heptane et du d-limonène
- 5.4 Méthode de mesure et d'analyse de l'ammoniac
- 5.5 Méthode de mesure et d'analyse du dioxyde d'azote
- 6 Génération des concentrations de gaz initiales
- 6.1 Généralités
- 6.2 Méthode de la bouteille de gaz
- 6.3 Méthode de vaporisation à température contrôlée
- 7 Chambre d'essai
- 8 Mesurage du CADR en mode de fonctionnement en aptitude maximale à la
- 8.1 Généralités
- 8.2 Essai de décroissance naturelle
- 8.3 Essai de décroissance totale
- 8.4 Calcul du débit d'air purifié
- 9 Procédures de calcul
- 9.1 Critères d'acceptation des points de données
- 9.2 Calcul des constantes de décroissance
- 9.3 Écart-type des échantillons de la pente de la droite de régression
- 9.4 Calcul du débit d'air purifié
- 9.5 Écart-type des échantillons du débit d'air purifié
- Annexe A
- Annexe B
- Annexe C
- Annexe D
- Annexe E
- Annexe F
- Annexe G
- Bibliographie
1 Domaine d'application
La présente partie de l'IEC 63086 spécifie des méthodes d'essai pour mesurer l'aptitude à la fonction des épurateurs d'air électrodomestiques et analogues destinés à la réduction des polluants en phase gazeuse.
Le présent document est destiné à mesurer la réduction de la concentration de certains polluants en phase gazeuse. Dans le cas des polluants olfactifs en phase gazeuse, la réduction de leur concentration ne coïncide pas nécessairement avec une réduction de l'intensité de leur odeur. Cet aspect peut uniquement être soumis à des essais olfactifs, ce qui ne relève pas du présent document.
NOTE Des méthodes d'essai sont à l'étude pour la détermination des éventuels produits de décomposition en phase gazeuse.
2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu'ils constituent, pour tout ou partie de leur contenu, des exigences du présent document. Pour les références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du document de référence s'applique (y compris les éventuels amendements).
IEC 63086-1:2020, Appareils d'épuration d'air électriques domestiques et appareils similaires - Méthodes de mesure de l'aptitude à la fonction - Partie 1: Exigences générales IEC 63086-2-1:2024, Appareils d'épuration d'air électriques domestiques et appareils similaires - Méthodes de mesure de l'aptitude à la fonction - Partie 2-1: Exigences particulières pour la détermination de la réduction des particules ISO 16000-3:2022, Air intérieur - Partie 3: Dosage du formaldéhyde et d'autres composés carbonylés dans l'air intérieur et dans l'air des chambres d'essai - Méthode par échantillonnage actif ISO 16000-6, Air intérieur - Partie 6: Dosage des composés organiques (COTV, COV, COSV) dans l'air intérieur et l'air de chambre d'essai par prélèvement actif sur tubes à sorbant, désorption thermique et chromatographie en phase gazeuse avec détection MS ou MS-FID ISO 16000-9, Air intérieur - Partie 9: Dosage de l'émission de composés organiques volatils d'échantillons de produits de construction et d'objets d'équipement - Méthode de la chambre d'essai d'émission
3 Termes, définitions et abréviations
3.1 Termes et définitions
Pour les besoins du présent document, les termes et définitions de l'IEC 63086-1:2020 ainsi que les suivants s'appliquent.
L'ISO et l'IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en normalisation, consultables aux adresses suivantes:
- IEC Electropedia: disponible à l'adresse https://www.electropedia.org/
- ISO Online browsing platform: disponible à l'adresse https://www.iso.org/obp
3.1.1 polluant en phase gazeuse
composé gazeux présent dans les environnements intérieurs à la suite d'une infiltration d'air extérieur, d'activités humaines en intérieur ou d'émissions provenant de matériaux présents en intérieur
3.1.2 gaz d'essai
polluant en phase gazeuse (3.1.1) choisi pour mesurer l'aptitude à la fonction des épurateurs d'air
3.1.3 taux de décroissance naturelle
taux de réduction du gaz d'essai (3.1.2) dans la chambre d'essai due à des facteurs naturels, tels que l'adsorption de surface, une réaction chimique et le renouvellement d'air −1 Note 1 à l'article: L'unité est exprimée par heure (h ).
3.1.4 taux de décroissance totale
taux de réduction du gaz d'essai (3.1.2) dans la chambre d'essai due à l'effet combiné du taux de décroissance naturelle (3.1.3) et du taux de décroissance en fonctionnement −1 Note 1 à l'article: L'unité est exprimée par heure (h ).
3.1.5 concentration de fond
concentration des gaz d'essai (3.1.2) dans la chambre d'essai après le nettoyage mais avant injection des gaz d'essai (3.1.2)
3.1.6 concentration initiale
concentration mesurée à l'intérieur de la chambre d'essai après injection et mélange des gaz d'essai (3.1.2)
3.1.7 COVT
composés organiques volatils totaux somme des concentrations de composés organiques volatils identifiés et non identifiés éluant entre et incluant le n-hexane et le n-hexadécane (conformément à l'ISO 16000-9)
3.1.8 méthode de mesure en temps réel
méthode de détermination de la concentration du gaz d'essai (3.1.2) à l'aide d'un instrument à lecture directe Note 1 à l'article: Un analyseur de chimiluminescence est un exemple d'instrument qui utilise une méthode de mesure en temps réel (3.1.8).
3.1.9 méthode d'échantillonnage intégrée
méthode de détermination de la concentration du gaz d'essai (3.1.2) par un processus périodique de capture de l'air et d'analyse ultérieure de l'échantillon Note 1 à l'article: La chromatographie en phase liquide à haute performance (HPLC) est un exemple d'instrument utilisant une méthode d'échantillonnage intégrée (3.1.9).
3.2 Abréviations
CADR (Clean Air Delivery Rate) débit d'air purifié CLA analyseur à chimiluminescence DNPH 2,4-dinitrophénylhydrazine DUT (Device Under Test) dispositif en essai FID (Flame Ionization Detector) détecteur à ionisation de flamme GC (Gas Chromatography) chromatographie en phase gazeuse HPLC (High Performance Liquid chromatographie en phase liquide à haute Chromatography) performance IC (Ion Chromatography) chromatographie par échange d'ions ou chromatographie ionique MS (Mass Spectrometry) spectrométrie de masse PTFE polytétrafluoroéthylène SIFT-MS (Selected Ion Flow Tube Mass spectrométrie de masse à flux d'ions Spectrometry) sélectionnés COVT composés organiques volatils totaux
4 Gaz d'essai et concentrations initiales pour les essais
4.1 Généralités
Les polluants en phase gazeuse sont, dans le cadre du présent document, classés en six groupes principaux: a) les aldéhydes, b) les hydrocarbures aromatiques, c) les hydrocarbures aliphatiques, d) les terpènes cycliques, e) les gaz odorants inorganiques et f) les gaz de combustion inorganiques. Les gaz d'essai représentatifs de chaque groupe sont décrits dans le Tableau 1, en tenant compte de leur prévalence en tant que polluants de l'air intérieur ainsi que de leur adéquation aux méthodes d'essai normalisées en termes de disponibilité, de dosabilité, de mesurabilité et de stabilité. Le CADR d'un épurateur d'air dépend généralement des gaz d'essai évalués, et les gaz d'essai représentatifs de chaque groupe se distinguent par une concentration initiale, une méthode de génération et une méthode de mesure de la concentration appropriées. Il n'est pas obligatoire de réaliser les essais avec tous les gaz d'essai représentatifs, mais chaque méthode pertinente pour l'application spécifique peut être choisie. En outre, il est possible de choisir d'autres gaz d'essai qui ne sont pas décrits comme des gaz d'essai représentatifs. Des exemples sont donnés à l'Annexe A. Les essais facultatifs de réduction de l'ozone par un épurateur d'air doivent être effectués conformément aux exigences de l'Annexe G. NOTE 1 Il est avéré que le CADR peut dépendre de la concentration initiale. Cependant, le présent document a pour objet de comparer différents épurateurs d'air soumis aux mêmes conditions d'essai. Par conséquent, les valeurs indiquées dans le Tableau 1 peuvent être utilisées. Si des concentrations initiales différentes sont utilisées, cette dérogation à la présente norme peut être clairement indiquée dans le rapport d'essai. Le laboratoire peut choisir de soumettre à l'essai chaque gaz séparément. Dans un tel cas, le laboratoire doit choisir une séquence d'essais qui évite de modifier les réglages de la technologie d'épuration évaluée, entre deux essais. Il est possible de doser plusieurs gaz d'essai en même temps pour le mesurage en parallèle du CADR à condition que ces gaz ne réagissent pas au contact d'autres gaz ou qu'ils ne modifient pas les performances de la technologie d'épuration évaluée sur les polluants soumis à l'essai. Par exemple, le toluène, le n-heptane et le d-limonène peuvent être soumis à des essais en parallèle. Toutefois, le formaldéhyde ne doit pas être soumis aux essais avec de l'ammoniac, car ces gaz peuvent réagir au contact l'un de l'autre. Il peut arriver que les gaz d'essai réagissent entre eux ou que l'un d'entre eux modifie les performances du dispositif de purification de l'air lorsqu'ils sont utilisés lors de deux essais consécutifs. Si tel est le cas, le filtre de l'échantillon sous essai doit être remplacé entre les mesures s'il est remplaçable. Dans le cas contraire, l'échantillon sous essai doit être mis en service dans la chambre d'essai, tandis que le système de traitement de l'air de la chambre fonctionne, jusqu'à ce que la concentration de fond soit inférieure aux valeurs indiquées au 8.2.3.
Tableau 1 – Gaz d'essai représentatifs Groupe de polluants en phase Gaz d'essai représentatif Concentration initiale gazeuse a) Aldéhydes Formaldéhyde +20%
−3 400 µg m
0%
b) Hydrocarbures aromatiques Toluène +20%
−3 800 µg m
0%
c) Hydrocarbures aliphatiques n-heptane +20% −3 800 µg m
0%
d) Terpènes cycliques d-limonène +20%
−3 800 µg m
0%
e) Gaz odorants inorganiques Ammoniac +20%
−3 700 µg m
0%
f) Gaz de combustion Dioxyde d'azote +20%
inorganiques −3 500 µg m
0%
NOTE 2 Des méthodes techniques, telles que l'adsorption (physique ou chimique) et la décomposition (comme l'oxydation), sont utilisées pour éliminer les polluants en phase gazeuse. Les polluants en phase gazeuse possèdent des propriétés physiques et chimiques différentes, par exemple solubilité polaire ou apolaire, pH acide ou basique, pression de vapeur, résistance à la décomposition par des substances oxydantes. Ainsi, l'efficacité d'un purificateur d'air peut dépendre du polluant en phase gazeuse, et les résultats ne peuvent pas être transposés tels quels à d'autres polluants en phase gazeuse.
NOTE 3 Essais séparés des gaz d'essai. L'exemple de séquence suivant peut être appliqué pour la technologie d'adsorption: (nettoyage) → Toluène → (nettoyage) → d-limonène → (nettoyage) → n-heptane → (nettoyage) → Ammoniac → (nettoyage) → Formaldéhyde → (nettoyage) → Dioxyde d'azote → (nettoyage). Essais en combinaison. Si le laboratoire possède les instruments de mesure capables de mesurer et de distinguer les grandeurs de toluène, d-limonène et n-heptane, il peut choisir de soumettre à l'essai ces trois substances chimiques simultanément. Dans ce cas, un exemple de séquence pour la technologie d'adsorption serait: (nettoyage) → [combinaison de toluène, d-limonène et n-heptane] → (nettoyage) → Ammoniac → (nettoyage) → Formaldéhyde → (nettoyage) → Dioxyde d'azote → (nettoyage).
NOTE 4 Les informations relatives aux gaz facultatifs, comme l'acétaldéhyde, etc., sont décrites à l'Annexe A. NOTE 5 De plus amples informations sur la concentration de fond peuvent être trouvées à l'Annexe D. NOTE 6 Les exigences particulières relatives à la détermination de la réduction d'ozone sont décrites à l'Annexe G.
4.2 Gaz d'essai représentatifs
4.2.1 Formaldéhyde
Utiliser un gaz de formaldéhyde commercial mélangé à de l'azote (N ) pour la méthode de la
bouteille de gaz ou une solution aqueuse composée de formaldéhyde (formol, CAS 50-00-0, sans méthanol) ou de paraformaldéhyde solide (CAS 30525-89-4) avec une pureté d'au moins 90,0 % pour la méthode de vaporisation à température contrôlée.
4.2.2 Toluène
Utiliser un gaz de toluène commercial mélangé à de l'azote (N ) pour la méthode de la bouteille
de gaz ou du toluène en phase liquide (CAS 108-88-3) avec une pureté GC d'au moins 99,9 % pour la méthode de vaporisation à température contrôlée.
4.2.3 n-heptane Utiliser un gaz de n-heptane commercial mélangé à de l'azote (N ) pour la méthode de la
bouteille de gaz ou du n-heptane en phase liquide (CAS 142-82-5) avec une pureté GC d'au moins 99,0 % pour la méthode de vaporisation à température contrôlée. 4.2.4 d-limonène Utiliser un gaz de d-limonène commercial mélangé à de l'azote (N ) pour la méthode de la
bouteille de gaz ou du d-limonène en phase liquide (CAS 5989-27-5) avec une pureté d'au moins 95 % pour la méthode de vaporisation à température contrôlée.
4.2.5 Ammoniac
Utiliser un gaz d'ammoniac commercial mélangé à de l'azote (N ) pour la méthode de la
bouteille de gaz ou une solution aqueuse composée d'ammoniac pour la méthode de vaporisation à température contrôlée
4.2.6 Dioxyde d'azote
Utiliser un gaz de dioxyde d'azote commercial mélangé à de l'azote (N ) pour la méthode de la
bouteille de gaz.
5 Méthodes pour mesurer la concentration des gaz d'essai
5.1 Généralités
La méthode de mesure suivante est spécifiée pour chaque substance. S'il peut être confirmé qu'une autre méthode procure une exactitude identique à la méthode spécifiée ou meilleure, alors celle-ci peut être utilisée. Des informations relatives aux autres méthodes possibles peuvent être trouvées à l'Annexe A.
Si le mesurage du CADR est effectué avec du dioxyde d'azote, la concentration en oxyde d'azote doit être surveillée en parallèle, car il peut exister des processus de conversion entre les deux gaz.
L'entretien de tous les instruments de mesure doit être effectué conformément aux instructions du fabricant. L'étalonnage des instruments avec des gaz étalons doit être effectué régulièrement conformément aux procédures normalisées du laboratoire.
5.2 Méthode de mesure et d'analyse du formaldéhyde
Conformément à l'ISO 16000-3, le mesurage et l'analyse du formaldéhyde doivent être effectués en utilisant des cartouches de gel de silice imprégné de 2,4-dinitrophénylhydrazine (DNPH) et la méthode de chromatographie en phase liquide à haute performance (HPLC). Lorsque des substances oxydantes comme l'ozone sont susceptibles d'être générées lors des essais, l'épurateur d'ozone décrit dans l'ISO 16000-3:2022, 5.2, doit être installé en face de la cartouche de DNPH.
5.3 Méthode de mesure et d'analyse du toluène, du n-heptane et du d-limonène
Conformément à l'ISO 16000-6, le mesurage et l'analyse du toluène, du n-heptane et du d-limonène doivent être effectués en utilisant des tubes de désorption thermique et la méthode de chromatographie en phase gazeuse/spectrométrie de masse (GC/MS) ou la méthode de chromatographie en phase gazeuse/détecteur à ionisation de flamme (GC/FID). La spectrométrie de masse à flux d'ions sélectionnés (SIFT-MS) peut être utilisée en lieu et place de la méthode GC/MS ou GC/FID.
5.4 Méthode de mesure et d'analyse de l'ammoniac
Le mesurage et l'analyse de l'ammoniac doivent être effectués en utilisant de l'eau distillée et la méthode de chromatographie par échange d'ions (IC) ou un analyseur de chimiluminescence.
5.5 Méthode de mesure et d'analyse du dioxyde d'azote
Un analyseur à chimiluminescence (CLA) doit être utilisé pour la mesure et l'analyse du dioxyde d'azote et de l'oxyde nitrique. Pour la mesure du NO , le NO présent dans l'échantillon est 2 2 d'abord converti en NO à l'aide d'un convertisseur, puis le NO ainsi obtenu est mesuré par le même analyseur.
6 Génération des concentrations de gaz initiales
6.1 Généralités
Chaque gaz d'essai est injecté dans la chambre d'essai par la méthode de la bouteille de gaz ou par la méthode de vaporisation à température contrôlée, puis est amené à la concentration initiale indiquée en 4.2.
6.2 Méthode de la bouteille de gaz
Les gaz d'essai contenus dans la bouteille, qui ont été préalablement amenés à une concentration prédéterminée par apport d'azote, sont injectés dans la chambre d'essai au moyen d'un régulateur approprié et un tube en polytétrafluoroéthylène (PTFE) ou en acier inoxydable.
6.3 Méthode de vaporisation à température contrôlée
Le réactif de haute pureté du gaz d'essai est placé dans un tube de perméation, un tube de diffusion ou un autre système d'injection à température contrôlée pour être vaporisé. De l'air filtré ou de l'azote sous forme gazeuse est utilisé comme gaz porteur pour injecter le gaz d'essai dans la chambre d'essai.
7 Chambre d'essai
La chambre d'essai est conforme à l'IEC 63086-1:2020, 5.6 à l'exception des modifications suivantes:
3 −1 Le débit du ventilateur de recirculation monté sur la paroi doit être compris entre 300 m h et 3 −1 −1 500 m h , et la vitesse maximale de l'écoulement d'air doit être de 15 m s mesurée au centre du ventilateur à 0,5 m de la face.
NOTE Pour les essais en phase gazeuse, régler le débit de recirculation pour maintenir des distributions représentatives et contrôlées dans la chambre. Un débit trop élevé peut entraîner le risque que les performances de l'épurateur d'air soient trop élevées alors que le débit d'air est faible, y compris pour les modèles sans ventilateur. Pour l'essai des particules grossières, le débit de recirculation est plus élevé pour maintenir les particules en suspension et assurer des concentrations uniformes.
8 Mesurage du CADR en mode de fonctionnement en aptitude maximale à la
fonction
8.1 Généralités
Réaliser les procédures d'essai 8.2 (taux de décroissance naturelle) et 8.3 (taux de décroissance totale) pour déterminer le CADR du DUT.
NOTE 1 Les éléments à inclure dans le rapport d'essai sont décrits à l'Annexe C.
NOTE 2 Une représentation graphique de la procédure d'essai est donnée à l'Annexe F.
8.2 Essai de décroissance naturelle
8.2.1 Généralités
L'essai de décroissance naturelle doit être effectué sans le DUT dans la chambre pour éviter toute contamination par les polluants en phase gazeuse.
Il est admis d'utiliser les résultats d'un essai de décroissance naturelle effectué dans la semaine précédant l'essai de décroissance totale.
8.2.2 Réglage du point d'échantillonnage
Placer le point d'échantillonnage conformément à l'IEC 63086-1:2020, 5.6.2. Pour la méthode de mesure en temps réel, le point d'échantillonnage doit être relié à une cartouche de DNPH, à un tube de désorption thermique ou à un instrument situé à l'extérieur de la chambre d'essai avec un tube en PTFE ou en acier inoxydable.
NOTE Pour les méthodes d'échantillonnage intégrées, la procédure suivante est utilisée à titre d'exemple pour réduire le plus possible les effets d'adsorption et de désorption dans le tube en réduisant la longueur du tube entre le point d'échantillonnage et le dispositif d'échantillonnage. Un tube est raccordé de la pompe d'échantillonnage à un dispositif d'échantillonnage (par exemple, une cartouche ou un tube de désorption thermique) situé à l'extérieur de la chambre d'essai. Le dispositif d'échantillonnage est installé sur une tige ou un support similaire, puis réglé de sorte que lorsqu'il est inséré, son extrémité soit positionnée précisément au point d'échantillonnage. Le dispositif est placé dans la chambre par une ouverture uniquement pendant un échantillonnage actif, autrement il est maintenu à l'extérieur de la chambre d'essai.
...