Status
Published
Publication Date
09-Aug-2026
Current Stage
6060 - International Standard published - 60 Publication
Start Date
10-Aug-2026
Due Date
21-Jun-2026
Completion Date
21-Jun-2026

Buy Documents

Standard

ISO 8980-3:2022/Amd 1:2026 - Ophthalmic optics — Uncut finished spectacle lenses — Part 3: Transmittance specifications and test methods — Amendment 1

Release Date:10-Aug-2026
English language (4 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ISO 8980-3:2022/Amd 1:2026 - Optique ophtalmique — Verres de lunettes finis non détourés — Partie 3: Spécifications relatives au facteur de transmission et méthodes d'essai — Amendement 1

Release Date:10-Aug-2026
French language (4 pages)
sale 15% off
Preview
sale 15% off
Preview

ISO 8980-3:2022/Amd 1:2026 is an ISO amendment to the transmittance part of the ophthalmic optics series for uncut finished spectacle lenses. It updates the requirements for transmittance properties and claims for uncut, unmounted finished spectacle lenses, including attenuation of solar radiation, and adds specific rules for claimed wavelength cut measurements.

What does ISO 8980-3:2022/Amd 1:2026 specify?

ISO 8980-3:2022/Amd 1:2026 updates ISO 8980-3:2022 by changing the scope wording, adding a definition for wavelength cut, adding a new requirement block for claimed wavelength cut, revising the measurement uncertainty language, updating the information supplied with the lens, and adding informative Annex G.

The amendment is organized around the affected clauses:

  • Clause 3 - adds the term wavelength cut
  • Clause 6.7 - adds requirements for claimed wavelength cut
  • Clause 7.2 - replaces the measurement uncertainty and method text
  • Clause 7.3 - updates the subheading wording
  • Clause 8 - updates product information requirements
  • Annex G - gives background on parameters affecting wavelength cut measurement
AnnexWhat it covers
Annex GParameters affecting the measurement of wavelength cut, including lens geometry and spectrophotometer effects

What are the key requirements of ISO 8980-3:2022/Amd 1:2026?

Claimed wavelength cut

If ISO 8980-3:2022/Amd 1:2026 is used to claim a wavelength cut, Clause 6.7 requires the lens to meet the claimed performance at the nominated wavelength and after ultraviolet irradiation. The amendment ties the claim to measured spectral transmittance, so the claim is not just descriptive - it must be testable.

At the nominated wavelength, spectral transmittance measured under 7.2 must be below the stated limit. For wavelengths from 280 nm up to 10 nm shorter than the nominated wavelength, the transmittance must be even lower. In practice, this means a manufacturer needs a clear test result for the cut-on region, not just a general UV statement.

Measurement uncertainty and test equipment

ISO 8980-3:2022/Amd 1:2026 sets uncertainty limits for spectral transmittance measurements in Clause 7.2.1. The allowed uncertainty is tighter at lower transmittance values, which matters because wavelength cut claims depend on measurements near very low transmission.

Clause 7.2.2 also specifies the test setup for wavelength cut claims:

  • a spectrophotometer or equivalent device
  • relative uncertainty within 10%
  • spectral uncertainty within ±1.0 nm
  • spectral resolution not greater than 1 nm
  • wavelength range from 280 nm to 780 nm
  • spectral bandwidth not exceeding 2 nm

For users, this means the lab equipment and calibration need to be good enough to distinguish small shifts in cut-on wavelength, especially in the ultraviolet range.

Specimen geometry and positioning

For transmittance determination, Clause 7.2.2 uses a plano lens of 2 mm thickness. If another thickness is used, that thickness must be stated. The measurement is taken at the reference point with the incident beam normal to the front surface.

That makes results comparable between products and test labs. If thickness or alignment varies, the wavelength cut can shift, so the test conditions must be controlled and documented.

Product information

Clause 8 requires the manufacturer or supplier to supply information on the package, in an accompanying document, or in other separately provided information. The amendment allows hard copy or digital delivery, including QR or data matrix code.

The supplied information must include any claimed absorption or transmittance properties in accordance with 6.6 and/or 6.7. In practice, buyers and users need a traceable statement of the optical claim alongside the lens.

What terms does ISO 8980-3:2022/Amd 1:2026 define?

  • wavelength cut - the lowest wavelength at which the spectral transmittance rises to a specified level.
  • spectral transmittance - the wavelength-by-wavelength transmittance used to judge whether a lens meets the claimed cut and UV performance.
  • plano lens - a lens used here as the test specimen reference for transmittance measurement, specified at 2 mm thickness.
  • spectrophotometer - the instrument used to measure spectral transmittance across the wavelength range.
  • FWHM - full width at half maximum, the bandwidth limit used when specifying the spectral performance of the instrument.

Who uses ISO 8980-3:2022/Amd 1:2026?

ISO 8980-3:2022/Amd 1:2026 is used by spectacle lens manufacturers and suppliers, optical test laboratories, and quality teams that verify transmittance claims. It is also relevant to buyers and specifiers who need to check whether a lens claim for wavelength cut or solar radiation attenuation is backed by a defined test method.

What changed in ISO 8980-3:2022/Amd 1:2026 from the previous edition?

ISO 8980-3:2022/Amd 1:2026 updates the 2022 edition by:

  • revising the scope wording to include transmittance properties and claims
  • adding the defined term wavelength cut
  • adding specific requirements for claimed wavelength cut
  • replacing the measurement uncertainty text in Clause 7.2
  • adding detailed spectrophotometer and specimen requirements for wavelength cut claims
  • updating the information that must accompany the lens
  • adding informative Annex G on factors affecting wavelength cut measurement

Which standards are used with ISO 8980-3:2022/Amd 1:2026?

ISO 8980-3:2022/Amd 1:2026 points readers to these documents for related guidance:

  • ISO/IEC Guide 98-3 - guidance for evaluating measurement uncertainty
  • ISO 18526-2:2020, Annex B - advice on uncertainty issues specific to lens measurement

What does the ISO 8980-3:2022/Amd 1:2026 document contain?

The amendment contains updated requirement text rather than a standalone full standard. It changes clause wording, adds a new defined term, sets out the test conditions for claimed wavelength cut, and revises the information that must be supplied with the lens.

It also includes an informative annex with background material. Annex G explains how lens geometry and spectrophotometer characteristics can affect measured wavelength cut, which helps users understand why the test conditions are tightly specified.

Relations

Effective Date
12-Feb-2026
Effective Date
29-Jul-2023
Effective Date
22-Jul-2023

Buy Documents

Standard

ISO 8980-3:2022/Amd 1:2026 - Ophthalmic optics — Uncut finished spectacle lenses — Part 3: Transmittance specifications and test methods — Amendment 1

Release Date:10-Aug-2026
English language (4 pages)
sale 15% off
Preview
sale 15% off
Preview
Standard

ISO 8980-3:2022/Amd 1:2026 - Optique ophtalmique — Verres de lunettes finis non détourés — Partie 3: Spécifications relatives au facteur de transmission et méthodes d'essai — Amendement 1

Release Date:10-Aug-2026
French language (4 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

TÜV Rheinland

TÜV Rheinland is a leading international provider of technical services.

DAKKS Germany Verified

TÜV SÜD

TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.

DAKKS Germany Verified

Sponsored listings

Frequently Asked Questions

ISO 8980-3:2022/Amd 1:2026 is a standard published by the International Organization for Standardization (ISO). Its full title is "Ophthalmic optics — Uncut finished spectacle lenses — Part 3: Transmittance specifications and test methods — Amendment 1". This standard covers: Ophthalmic optics — Uncut finished spectacle lenses — Part 3: Transmittance specifications and test methods — Amendment 1

Ophthalmic optics — Uncut finished spectacle lenses — Part 3: Transmittance specifications and test methods — Amendment 1

ISO 8980-3:2022/Amd 1:2026 is classified under the following ICS (International Classification for Standards) categories: 11.040.70 - Ophthalmic equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 8980-3:2022/Amd 1:2026 has the following relationships with other standards: It is inter standard links to EN ISO 8980-3:2022/A1:2026, ISO 23274-2:2021, ISO 8980-3:2022. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ISO 8980-3:2022/Amd 1:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Annex G provides some informative background to the measurement methodology."
  • Annex G

Scope Replace the following sentence:

“This document specifies requirements for the transmittance properties of uncut and unmounted finished spectacle lenses, including attenuation of solar radiation.” by:

"This document specifies requirements and claims for the transmittance properties of uncut and unmounted finished spectacle lenses, including attenuation of solar radiation.”

Clause 3 Add a new term 3.1 as follows:

"3.1 wavelength cut the lowest wavelength at which the spectral transmittance rises to a specified level Note 1 to entry see 6.7.2 for the requirement"

6.7 Add a new paragraph 6.7 as follows:

"6.7 Claimed wavelength cut

6.7.1 General

In cases where it is claimed that a lens has a specific wavelength cut, the relevant requirement(s) in 6.7.2 shall apply.

NOTE For information, see Annex G.

6.7.2 Wavelength cut

For lenses claimed to have a wavelength cut at a nominated wavelength, the spectral transmittance measured according to 7.2 shall be less than 5,0 % at the nominated wavelength. Spectral transmittance for all wavelengths from 280 nm to 10 nm shorter than the nominated wavelength shall be less than 1,0 %.

ISO 8980-3:2022/Amd.1:2026(en) Following ultraviolet irradiation as specified in 7.7, the claimed transmittance performance shall continue to be satisfied."

7.2 Delete the following:

“The uncertainties of the test methods determining transmittance values shall be not greater than:

- 2 % absolute, for transmittance >20 %; - 1 % absolute, for luminous transmittance ≤20 %; - 10 % relative, for UV transmittance of lenses with luminous transmittance ≤ 20 %. These measurement uncertainties shall be based on a confidence level of 95 %. NOTE Guidelines for evaluating uncertainty can be found in ISO/IEC Guide 98-3. Advice on the specific issues in evaluating uncertainty of measurement in lenses can be found in ISO 18526-2:2020, Annex B. The user can refer to operating manuals and other information provided by manufacturers of specific instruments for additional information.”

7.2.1 and 7.2.2 Add the two new paragraphs as follows:

"7.2.1 General The uncertainties of measurement in determining spectral transmittance values shall not be greater than - 2,0 % absolute, for spectral transmittance >20 %, - 1,0 % absolute, for spectral transmittance in the range of ≤20 %, ≥5 %, and - 0,5 % absolute, for spectral transmittance <5 %.

...

Domaine d’application Remplacer la phrase suivante:

“Le présent document spécifie les exigences relatives aux propriétés de transmission des verres de lunettes finis non détourés et non montés, ainsi qu'à l'atténuation du rayonnement solaire.” par:

“Le présent document spécifie les exigences et les revendications relatives aux propriétés de transmission des verres de lunettes finis non détourés et non montés, ainsi qu'à l'atténuation du rayonnement solaire.”

Article 3 Ajouter un terme 3.1 comme suit:

“3.1 longueur d'onde de coupure longueur d'onde la plus basse à laquelle le facteur de transmission spectrale s'élève à un niveau spécifié Note 1 à l'article se référer à 6.7.2 en matière d'exigence”

6.7 Ajouter un nouveau paragraphe 6.7 comme suit:

“6.7 Longueur d'onde de coupure revendiquée

6.7.1 Généralités

Dans les cas où il est revendiqué qu'un verre présente une longueur d'onde de coupure spécifique, les exigences correspondantes en 6.7.2 doivent s'appliquer.

NOTE Pour information, voir l'Annexe G.

6.7.2 Longueur d'onde de coupure

Pour les verres revendiquant une longueur d'onde de coupure à une longueur d'onde désignée, le facteur de transmission spectrale mesuré conformément à 7.2 doit être inférieur à 5,0 % à la longueur d'onde désignée.

ISO 8980-3:2022/Amd.1:2026(fr) Le facteur de transmission spectrale pour toutes les longueurs d'onde comprises entre 280 nm et 10 nm de moins que la longueur d'onde désignée doit être inférieur à 1,0 %. Après une irradiation aux ultraviolets, comme spécifié en 7.7, les performances revendiquées doivent continuer à être respectées.”

7.2 Supprimer ce qui suit:

“L'incertitude des méthodes d'essai pour la détermination des valeurs du facteur de transmission ne doit pas dépasser:

  • 2 % en valeur absolue, pour un facteur de transmission > 20 %;
  • 1 % en valeur absolue, pour un facteur de transmission dans le visible ≤ 20 %;
  • 10 % en valeur relative, pour le facteur de transmission des UV des verres dont le facteur de transmission dans le visible est ≤ 20 %.

Ces incertitudes de mesure doivent reposer sur un niveau de confiance de 95 %. NOTE Des lignes directrices sur l'évaluation de l'incertitude sont disponibles dans le Guide ISO/IEC 98-3. Des conseils sur les problèmes spécifiques rencontrés lors de l'évaluation de l'incertitude de mesure des verres sont disponibles dans l'ISO 18526-2:2020, Annexe B. L'utilisateur peut se référer aux manuels d'utilisation et aux autres informations fournies par les fabricants d'instruments spécifiques pour toute information supplémentaire.”

7.2.1 et 7.2.2 Ajouter les deux paragraphes suivants:

“7.2.1 Généralités L'incertitude de mesure pour la détermination des valeurs du facteur de transmission spectrale ne doit pas dépasser:

...