Abstract

This document addresses the choice of proper zeta-potential determination technology and measurement operation for applications such as new product design, optimization of existing products, quality control during processing and/or during usage of the product. It does not provide a complete procedure for zeta-potential measurements. The instructions and key points addressed in this document are considered useful for performing zeta-potential measurements as specified in ISO 13099-1, ISO 13099-2, and ISO 13099-3.

Status
Not Published
Current Stage
5000 - Final text received or FDIS registered for formal approval - 50 Approval
Start Date
07-Aug-2026
Due Date
14-Apr-2026
Completion Date
14-Apr-2026

Buy Documents

Draft

ISO/DTS 19997 - Guidance and requirements for good practices in zeta-potential measurement

Release Date:16-Nov-2026
English language (26 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/DTS 19997 - Guidance and requirements for good practices in zeta-potential measurement

Release Date:16-Nov-2026
English language (26 pages)
sale 15% off
sale 15% off

ISO/DTS 19997 is an ISO technical specification that gives guidance and requirements for good practices in zeta-potential measurement. It helps users choose the right determination technology and run the measurement for new product design, optimization of existing products, and quality control during processing and use. It supports zeta-potential work done under ISO 13099-1, ISO 13099-2, ISO 13099-3, and ISO 13100, rather than replacing those detailed measurement methods.

What does ISO/DTS 19997 specify?

ISO/DTS 19997 specifies good practice for selecting and operating zeta-potential measurement techniques for particles, dispersions, porous materials, and related flat-surface cases. It does not provide a complete measurement procedure, so users still need the detailed method standards for the actual determination.

The document is organized into general guidance, terms and symbols, then method-specific clauses for electrophoretic light scattering, colloid vibration current, and DC streaming potential. It ends with two informative annexes that extend the discussion to non-polar media and to materials with a flat surface.

AnnexWhat it covers
Annex AZeta-potential measurement for particles in non-polar media
Annex BZeta-potential determination for materials with a flat surface

What are the key requirements of ISO/DTS 19997?

ISO/DTS 19997 focuses on making the measurement representative, stable, and interpretable. The most important practical message is that zeta-potential is sensitive to sample preparation, medium composition, and the theory used to convert raw data into ζ-potential.

Sampling, dilution, and sample handling

Clause 6.2 says the test sample has to represent the batch, and the material should be checked for adequate dispersion before measurement. If particles sediment during the measurement window, optical methods may no longer represent the whole sample. In practice, that means users need to verify suspension stability before putting a sample on the instrument.

Clause 6.3 requires dilution to preserve the original electrochemical state of the system. The preferred approach is equilibrium dilution, where the same liquid as in the original system is used as the diluent. This matters because simple dilution with deionized water can change pH, ionic strength, and surface chemistry, which changes the measured zeta-potential.

Sample stability and reporting

Clause 6.3.2 recommends time-sequenced measurements to show that the sample is stable. It also recommends checking pH and/or conductivity before and after each measurement, and reporting rates of change if the sample drifts. For a buyer or lab manager, this means a single value is not enough if the sample changes during the test.

Clause 6.2 also expects a detailed report of how the sample was handled and how the diluent was prepared. That makes the result traceable and easier to compare across batches, instruments, or laboratories.

Measurement quality and error control

Clause 6.4 links good practice to repeatability, robustness, and signal quality. The document points to consecutive measurements, checks for dilution and voltage effects, and review of the raw signal when peaks are broad or multiple. In practice, poor signal-to-noise or drifting trends are warning signs that the data should be questioned before being used for decisions.

Clause 6.5 lists common error sources, including contamination, carryover between samples, unsuitable medium properties, incorrect instrument inputs, bubbles, carbon dioxide uptake, and unsuitable calculation theory. This is important because small amounts of contamination or a wrong viscosity or permittivity value can distort the result without obvious changes in pH or conductivity.

Electrophoretic light scattering

Clause 6.6 describes a special cell for concentrated samples, using forward scattering with a transparent electrode to reduce multiple scattering. It is intended for concentrated dispersions such as emulsions, liposomes, latex, paper/pulp, biological samples, inorganic materials, and organic pigments. The practical point is that concentration, conductivity, and particle adsorption on the electrode all affect whether the method remains valid.

Electroacoustic measurement

Clause 7 says electroacoustic measurement can be used in Electric Sonic Amplitude (ESA) mode or colloid vibration current (CVI) mode. The instrument needs suitable calibration, certified reference material, and input data for particle and liquid properties such as density, viscosity, and dielectric constant. For routine work, this means the software and materials database are part of the measurement quality, not just the probe.

Clause 7 also states that electroacoustic methods require sufficiently high particle concentration, typically above the point where electrophoretic methods are used. The document notes that the software must handle the ion contribution to the signal and that particle size can become an input parameter for larger particles. That matters because the method is not just a zeta-potential reading - it is a coupled calculation that depends on sample characterization.

Streaming potential measurement

Clause 8 explains that DC streaming potential applies to porous materials such as plugs of granular particles or fibres, while tangential mode for flat surfaces is discussed in Annex B. The sample must be mounted so that the pressure-driven flow is laminar and the Smoluchowski equation can be applied.

Clause 8.2 and 8.4 require suitable particle size, sample mass, permeance, and test liquid composition. The liquid is usually a dilute monovalent electrolyte, and the document gives a practical ionic-strength range for reliable work. This matters because too little ionic strength, too much surface conductance, or poorly chosen sample mass can make the conversion to zeta-potential unreliable.

Clause 8.3 requires a linear relation between streaming potential and pressure difference, either over a pressure range or at several constant pressure points. Clause 8.4.3 also requires initial rinsing to equilibrate the solid-liquid interface and remove trapped air. For users, that means a valid streaming potential test is not just about measuring a voltage - it is also about proving that the pressure response is linear and the sample is properly wetted.

Clause 8.6 covers preventive maintenance. It calls for electrode conditioning, cleaning of wetted parts, regular calibration of pH and conductivity probes, and performance checks with a reference material. This is what keeps the instrument trustworthy over time.

What terms does ISO/DTS 19997 define?

  • Electrokinetic potential, zeta-potential (ζ-potential) - the electric potential difference between the slipping plane and the bulk liquid.
  • Electrophoretic mobility (μ) - the particle velocity per unit electric field strength in electrophoresis.
  • Colloid vibration current (CVI) - the alternating current generated between two electrodes when a dispersion is exposed to an ultrasonic field.
  • Colloid vibration potential (CVU) - the alternating potential difference generated in the same ultrasonic condition.
  • Electric double layer - the charge distribution that forms at and near a surface in contact with a liquid.
  • Streaming potential - the potential difference generated when liquid flows through a capillary, plug, diaphragm, or membrane under a pressure gradient.
  • Slipping plane - the nearby interface plane where liquid begins to move relative to the surface under shear.
  • Isoelectric point - the liquid-medium condition, usually a pH value, at which zeta-potential is zero.

Who uses ISO/DTS 19997?

ISO/DTS 19997 is used by engineers, researchers, and quality personnel who measure zeta-potential on colloids, dispersions, porous bodies, and flat surfaces. It is relevant in formulation work, product development, process control, and quality control.

Typical users include laboratories working with particles, emulsions, liposomes, latex, paper and pulp, biological materials, inorganic materials, organic pigments, fibres, membranes, and porous solids. It is also useful for buyers and method owners who need to choose between optical, acoustic, and streaming-potential approaches for a given sample type.

What changed in ISO/DTS 19997 from the previous edition?

ISO/DTS 19997 is the first edition of the technical specification and cancels and replaces ISO/TR 19997:2018.

Which standards are used with ISO/DTS 19997?

ISO/DTS 19997 is meant to be used together with the method standards it names for detailed determination work:

  • ISO 13099-1 - electroacoustic and electrokinetic phenomena for zeta-potential determination.
  • ISO 13099-2 - optical methods for zeta-potential determination, including electrophoretic light scattering.
  • ISO 13099-3 - acoustic methods for zeta-potential determination, including colloid vibration current.
  • ISO 13100 - streaming potential and streaming current methods for porous materials.
  • ISO 14887 - dispersing procedures for powders in liquids, useful when preparing particle samples.
  • ISO 15901-1 - pore size distribution and porosity terminology used in the document’s definitions.

What does the ISO/DTS 19997 document contain?

ISO/DTS 19997 contains general guidance on what zeta-potential means, how it depends on the liquid-solid interface, and why it is not an intrinsic property. It includes a method-selection table that matches driving force and sample type to the appropriate measurement approach.

The document also contains a figure and discussion of a special forward-scattering cell for concentrated samples, a figure showing electroacoustic probe setups, and a figure for streaming-potential sample holders. It provides a table of recommended sample masses for granular particles in streaming-potential work, and another table-like comparison of measurement methods for particles and porous media.

The formulas and figures are used to explain the Smoluchowski relation, streaming current and streaming potential behavior, and the conditions needed for reliable calculation. Annex A gives practical guidance for non-polar liquids, and Annex B shows how the same principles extend to flat-surface materials using tangential streaming potential or related optical approaches.

Relations

Effective Date
15-Apr-2023

Buy Documents

Draft

ISO/DTS 19997 - Guidance and requirements for good practices in zeta-potential measurement

Release Date:16-Nov-2026
English language (26 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/DTS 19997 - Guidance and requirements for good practices in zeta-potential measurement

Release Date:16-Nov-2026
English language (26 pages)
sale 15% off
sale 15% off

Get Certified

Connect with accredited certification bodies for this standard

BSMI (Bureau of Standards, Metrology and Inspection)

Taiwan's standards and inspection authority.

TAF Taiwan Verified

IMP NDT d.o.o.

Non-destructive testing services. Radiography, ultrasonic, magnetic particle, penetrant, visual inspection.

SA Slovenia Verified

Inštitut za kovinske materiale in tehnologije

Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

ISO/DTS 19997 is a draft published by the International Organization for Standardization (ISO). Its full title is "Guidance and requirements for good practices in zeta-potential measurement". This standard covers: This document addresses the choice of proper zeta-potential determination technology and measurement operation for applications such as new product design, optimization of existing products, quality control during processing and/or during usage of the product. It does not provide a complete procedure for zeta-potential measurements. The instructions and key points addressed in this document are considered useful for performing zeta-potential measurements as specified in ISO 13099-1, ISO 13099-2, and ISO 13099-3.

This document addresses the choice of proper zeta-potential determination technology and measurement operation for applications such as new product design, optimization of existing products, quality control during processing and/or during usage of the product. It does not provide a complete procedure for zeta-potential measurements. The instructions and key points addressed in this document are considered useful for performing zeta-potential measurements as specified in ISO 13099-1, ISO 13099-2, and ISO 13099-3.

ISO/DTS 19997 is classified under the following ICS (International Classification for Standards) categories: 17.220.20 - Measurement of electrical and magnetic quantities; 19.120 - Particle size analysis. Sieving. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO/DTS 19997 has the following relationships with other standards: It is inter standard links to ISO/TR 19997:2018. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ISO/DTS 19997 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


FINAL DRAFT
Technical
Specification
ISO/TC 24/SC 4
Guidance and requirements for
Secretariat: BSI
good practices in zeta-potential
Voting begins on:
measurement
2026-11-30
Voting terminates on:
2027-01-25
RECIPIENTS OF THIS DRAFT ARE INVITED TO SUBMIT,
WITH THEIR COMMENTS, NOTIFICATION OF ANY
RELEVANT PATENT RIGHTS OF WHICH THEY ARE AWARE
AND TO PROVIDE SUPPOR TING DOCUMENTATION.
IN ADDITION TO THEIR EVALUATION AS
BEING ACCEPTABLE FOR INDUSTRIAL, TECHNO­
LOGICAL, COMMERCIAL AND USER PURPOSES, DRAFT
INTERNATIONAL STANDARDS MAY ON OCCASION HAVE
TO BE CONSIDERED IN THE LIGHT OF THEIR POTENTIAL
TO BECOME STAN DARDS TO WHICH REFERENCE MAY BE
MADE IN NATIONAL REGULATIONS.
Reference number
FINAL DRAFT
Technical
Specification
ISO/TC 24/SC 4
Guidance and requirements for
Secretariat: BSI
good practices in zeta-potential
Voting begins on:
measurement
Voting terminates on:
© ISO 2026
All rights reserved.
RECIPIENTS OF THIS DRAFT ARE INVITED TO SUBMIT,
WITH THEIR COMMENTS, NOTIFICATION OF ANY
This ISO publication is protected by copyright and is owned by ISO and/or its licensors.
RELEVANT PATENT RIGHTS OF WHICH THEY ARE AWARE
The content of this ISO publication is provided under licence, not sold. Use is subject to the applicable licence terms issued by ISO,
AND TO PROVIDE SUPPOR TING DOCUMENTATION.
an ISO member body, or an authorized third-party distributor.
IN ADDITION TO THEIR EVALUATION AS
BEING ACCEPTABLE FOR INDUSTRIAL, TECHNO­
Except as required for implementation or expressly permitted by a separate licence, no part of this ISO publication may be
LOGICAL, COMMERCIAL AND USER PURPOSES, DRAFT
reproduced, distributed, modified, used, or made available in any form or by any means – electronic or mechanical, including
INTERNATIONAL STANDARDS MAY ON OCCASION HAVE
photocopying, scanning, recording, or posting on internal or external digital platforms. TO BE CONSIDERED IN THE LIGHT OF THEIR POTENTIAL
TO BECOME STAN DARDS TO WHICH REFERENCE MAY BE
Any use beyond the scope of the granted rights is prohibited and may result in legal action.
MADE IN NATIONAL REGULATIONS.
ISO copyright office
CP 401 • CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
Reference number
ii
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Symbols . 4
5 Methods for zeta-potential determination . 4
6 Electrophoretic light scattering . 5
6.1 General .5
6.2 Sampling and sample inspection .5
6.3 Sample dilution .6
6.3.1 Sample dilution procedures .6
6.3.2 Sample stability test .7
6.4 Measurement uncertainty .7
6.5 Sources of error .7
6.5.1 Carryover contamination from previous samples .7
6.5.2 Inappropriate sample preparation procedures .8
6.5.3 Inappropriate samples for electrophoretic light scattering measurement .8
6.5.4 Inappropriate liquid medium .8
6.5.5 Incorrect entries of parameters by the operator .8
6.5.6 Air bubbles .9
6.5.7 Inappropriate theory for calculating zeta-potential from the measured
electrophoretic mobility .9
6.5.8 Carbon dioxide .9
6.5.9 Effect of the applied electric field on susceptible samples .9
6.6 Measurement of concentrated samples .10
7 Colloid vibration current .11
8 DC streaming potential .13
8.1 General . 13
8.2 Sample preparation . 13
8.3 Measurement methods . 15
8.4 Measurement conditions .16
8.4.1 Sample mass and permeance .16
8.4.2 Composition of test liquid .17
8.4.3 Equilibration of the solid-liquid interface .17
8.4.4 Recording of solid-liquid interfacial processes .18
8.5 Applicability of the Smoluchowski equation .19
8.6 Preventive maintenance .19
Annex A (informative) Zeta-potential measurement for particles in non-polar media .21
Annex B (informative) Zeta-potential determination for materials with a flat surface .22
Bibliography .25

iii
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent rights
in respect thereof. As of the date of publication of this document, ISO had not received notice of (a) patent(s)
which may be required to implement this document. However, implementers are cautioned that this may not
represent the latest information, which may be obtained from the patent database available at www.iso.org/
patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 24, Particle characterization including sieving,
Subcommittee SC 4, Particle characterization.
This first edition of ISO/TS 19997 cancels and replaces ISO/TR 19997:2018.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.

iv
Introduction
Zeta-potential is the electric potential at the slipping plane of a colloidal particle in suspension or porous
material immersed in liquid, relative to the bulk liquid, which is often used to investigate the isoelectric
point (IEP) and surface adsorption for particles in liquid media, and as an indicator in comparing different
samples regarding electrostatic-dependent dispersion stability. Zeta-potential is not a directly measurable
quantity, but one that is established using an appropriate theory. Furthermore, zeta-potential is not an
intrinsic property of suspended particles; it depends on both particle and medium properties, and how they
interact at the interface. Any variation in the liquid chemical and ionic composition affects this interfacial
equilibrium and, consequently, zeta-potential. Therefore, sample preparation and measurement procedures
can both affect the measurement result. Incorrect conclusions often result from artefacts in sample
preparation and issues arising from measurement procedures, or incorrect application of theoretical models
for calculating zeta-potential from measurement results.
This document provides general guidelines for sample preparation and measurement procedures for the
determination of zeta-potential by optically based electrophoretic mobility measurement, by DC streaming
potential measurement, and electroacoustic measurement.

v
FINAL DRAFT Technical Specification ISO/DTS 19997:2026(en)
Guidance and requirements for good practices in zeta-
potential measurement
1 Scope
This document provides information on the zeta-potential measurement operation for applications such
as new product design, optimization of existing products, quality control during processing and/or during
usage of the product.
It does not provide a complete measurement procedure for zeta-potential determination. The information
[1] [2]
provided can help in performing zeta-potential determination according to ISO 13099-1 , ISO 13099-2 ,
[3] [4]
ISO 13099-3 and ISO 13100 .
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
3.1
Brownian motion
random movement of particles suspended in a liquid caused by thermal movement of medium molecules
[5]
[SOURCE: ISO 13099-2:2025 , 3.1.1]
3.2
colloid vibration current
CVI
a.c. current generated between two electrodes, placed in a dispersion, if the latter is subjected to an
ultrasonic field
Note 1 to entry: Colloid vibration current is expressed in amperes.
[6]
[SOURCE: ISO 13099-3:2014 , 3.3.1]
3.3
colloid vibration potential
CVU
a.c. potential difference generated between two electrodes, placed in a dispersion, if the latter is subjected
to an ultrasonic field
Note 1 to entry: Colloid vibration potential is expressed in volts.
[6]
[SOURCE: ISO 13099-3:2014 , 3.3.2]

3.4
electric double layer
spatial charge distribution that appears on and at the vicinity of the surface of an object when it is placed in
contact with a liquid
[7]
[SOURCE: ISO 13100:2024 , 3.1.2]
3.5
electroacoustics
phenomena arising from the coupling between the ultrasound field and electric field in a liquid that contains
ions
[8]
[SOURCE: ISO 13099-1:2012 , 2.3]
3.6
electrokinetic potential
zeta-potential
ζ-potential
difference in electric potential between that at the slipping plane and that of the bulk liquid
Note 1 to entry: Electrokinetic potential is expressed in volts.
[8]
[SOURCE: ISO 13099-1:2012 , 2.1.8]
3.7
electroosmotic flow
motion of liquid through or past a charged surface, e.g. an immobilized set of particles, a porous plug, a
capillary or a membrane, in response to an applied electric field, which is the result of the force exerted by
the applied field on the countercharge ions in the liquid
[8]
[SOURCE: ISO 13099-1:2012 , 2.2.1]
3.8
electrophoresis
movement of charged colloidal particles or polyelectrolytes, immersed in a liquid, under the influence of an
external electric field
[8]
[SOURCE: ISO 13099-1:2012 , 2.2.4]
3.9
electrophoretic mobility
μ
electrophoretic velocity per electric field strength
Note 1 to entry: Electrophoretic mobility is positive if the particles move toward lower potential (negative electrode)
and negative in the opposite case.
Note 2 to entry: Electrophoretic mobility is expressed in metres squared per volt second.
[8]
[SOURCE: ISO 13099-1:2012 , 2.2.5]
3.10
ion vibration current
IVI
a.c. electric current created from different displacement amplitudes in an ultrasound wave due to the
difference in the effective mass or friction coefficient between anion and cation
Note 1 to entry: Ion vibration current is expressed in amperes.
[6]
[SOURCE: ISO 13099-3:2014 , 3.3.4]

3.11
isoelectric point
condition of liquid medium, usually the value of pH, that corresponds to zero zeta-potential
[8]
[SOURCE: ISO 13099-1:2012 , 2.1.10]
3.12
permeance
rate of liquid flow per unit area and per unit static pressure differential
Note 1 to entry: Permeance is expressed in metres per Pascal second.
3.13
pore
cavity or channel which is deeper than it is wide, otherwise it is part of the material’s roughness
[9]
[SOURCE: ISO 15901-1:2016 , 3.5]
3.14
porosity
ratio of the volume of the accessible pores and voids to the bulk volume occupied by an amount of the solid
[9]
[SOURCE: ISO 15901-1:2016 , 3.27]
3.15
sedimentation potential
U
sed
potential difference sensed by two electrodes placed some vertical distance apart in a dispersion in which
particles are sedimenting under the effect of gravity
Note 1 to entry: When the sedimentation is produced by a centrifugal field, the phenomenon is called centrifugation
potential.
Note 2 to entry: Sedimentation potential is expressed in volts.
[8]
[SOURCE: ISO 13099-1:2012 , 2.2.7]
3.16
slipping plane
shear plane
abstract plane in the vicinity of the interface between liquid and surface where liquid starts to slide relative
to the surface under influence of a shear stress
[5]
[SOURCE: ISO 13099-2:2025 , 3.1.10]
3.17
streaming current
I , noun
str
current through a porous body resulting from the motion of fluid under an applied pressure gradient
Note 1 to entry: Streaming current is expressed in amperes.
[8]
[SOURCE: ISO 13099-1:2012 , 2.2.8]
3.18
streaming potential
U , noun
str
potential difference at zero electric current, caused by the flow of liquid under a pressure gradient through a
capillary, plug, diaphragm or membrane
Note 1 to entry: Streaming potentials are created by charge accumulation caused by the flow of counter charges inside
capillaries or pores.
Note 2 to entry: Streaming potential is expressed in volts.
[8]
[SOURCE: ISO 13099-1:2012 , 2.2.10]
3.19
streaming potential coupling coefficient
U /ΔP, noun
str
electrokinetic phenomenon determined by the slope of the linear dependence of the measured streaming
potential on an applied pressure gradient
Note 1 to entry: Streaming potential coupling coefficient is expressed in volts per pascal.
[7]
[SOURCE: ISO 13100:2024 , 3.2.8]
4 Symbols
K electric conductivity
P pressure
U streaming potential
str
ε vacuum permittivity
o
ε relative permittivity of the medium
m
ε eta dynamic viscosity of the medium
m
μ electrophoretic mobility
ζ electrokinetic potential, zeta-potential
5 Methods for zeta-potential determination
Zeta-potential (ζ) is the electric potential at a slipping plane that separates the mobile solvent from solvent
molecules that associate with the surfaces of particles, fibres, porous material, or solids with a planar surface
(see Annex B). Zeta-potential is not an intrinsic material property; it depends on the interaction between
the surface of the particle or the solid material and the liquid phase in which the particle is dispersed, or
the solid material is in contact with. Any variation of the liquid chemical and ionic composition affects this
[10] [11] [12]
interaction and, consequently, affect zeta-potential , , .
Zeta-potential is frequently used to predict the stability of a suspension or the adhesion of suspended
particles onto macroscopic surfaces (e.g., cellulose fibres, membranes). This is because interaction between
particles or between particles and surfaces is often governed by the ion distribution in the diffuse layer,
which is closely related to zeta-potential. Whenever electrostatic forces dominate interactions between
particles or between particles and surfaces, zeta-potential is the principal system parameter to evaluate
[13]
these interactions . Repulsion requires high surface charges of equal sign, whereas attraction occurs in
the absence of surface charge or for oppositely charged or “patchy” surfaces containing both negatively and
positively charged domains. High zeta-potential absolute values cause strong repulsion between dispersed
particles and, thus, favour the stabilisation of colloidal suspensions. This effect is even more pronounced
for thick double layers in low electrolyte content. In contrast, low zeta-potential absolute values (positive
or negative), zeta-potentials of opposite sign (opposite polarity), or high electrolyte concentrations (thin
double layers), can promote agglomeration. Hence, zeta-potential can be principally employed to predict
the suspension stability, which is frequently determined as a function of the pH and/or the concentration
of indifferent electrolytes and surface-active ionic species (e.g., ionic surfactants, multi-valent ions and
[14] [15]
polyelectrolytes) , .
The perception that there is a universally valid critical zeta-potential value that defines the transition from
unstable to stable suspensions has been proven only in limited applications. Zeta-potential values must be
used carefully when evaluating the suspension stability. It is recommended that in formulation work to

predict stability, a second measurand (e.g., size distribution, turbidity, viscosity, etc.) can be monitored and
correlated to verify the conclusion derived from zeta-potential measurement.
The zeta-potential analysis for this variety of different materials requires different measurement techniques
(see Table 1). Zeta-potential can be probed by imposing a relative motion between bulk solvent and particle.
Zeta-potential measurements on colloidal dispersion are frequently conducted via either electrophoresis or
electroacoustics for applications under different sample conditions (e.g., diameter range from nanometre up
-4 [16]
to tens of micrometres with particle volume fraction from roughly 10 % to 40 %) .
The determination of the zeta-potential for porous media (consolidated porous body, plug of granular
particles, or plug of fibres) follows the same principle of a relative motion between the bulk solvent and
the respective porous material surface via either DC or AC streaming potential and streaming current
[17]
measurements .
Table 1 — Appropriate methods for zeta-potential determination of particles and porous media
Driving force System type DC, Low frequency (kHz) High frequency (MHz)
Electric particulates Electrophoretic mobility Electrokinetic sonic
a
Amplitude
a,b a,b
porous, flat Electroosmotic flow Electro-seismic effect
a,b
Mechanical, gravitational particulates Sedimentation potential Colloid vibration current
a
porous, flat Streaming potential, Seismo-electric effect
streaming current
a
This method is not discussed in this document.
b
This method is not accessible through a commercially available analytical instrument.
6 Electrophoretic light scattering
6.1 General
Electrophoretic light scattering (ELS) is an indirect ensemble method for measuring electrophoretic mobility
via the Doppler shifts in scattered light. In an ELS experiment, coherent incident light illuminates dispersed
particles in a liquid that are subjected to an applied electric field. Charged particles move towards either
the anode or the cathode, depending on the sign of their net charge. Because of the motion, the frequency of
scattered light from particles is shifted due to the Doppler effect. From the frequency shift distribution, the
particle electrophoretic mobility distribution can be determined.
6.2 Sampling and sample inspection
The electrophoretic mobility (μ) measured in a sample is only valid for a batch of material if the test sample
is representative of that batch and has been sampled adequately.
The material to be analysed should be inspected to ensure the particles have been dispersed adequately
without any sedimentation occurring upon standing for a period relevant to the measurement time. If
particles sediment during measurement, measurement using optical methods is potentially not appropriate
since particles remaining in the laser beam possibly do not represent the whole sample (e.g., with
polydisperse samples, large particles will settle differentially resulting in a biased measurement of the
smaller size particles).
Considerable care shall be exercised during sample preparation to avoid changing the electrophoretic
mobility of the sample to be tested. Labware that comes into direct contact with the sample, such as a
glass beaker or syringe, may adsorb specific ions from the medium or add residual contaminants to the
sample that remain from a prior cleaning process or from production of the labware itself. Disposable plastic
preparation beakers and pipettes are generally preferred, so long as they are chemically compatible with
the sample.
A detailed report of how precisely the sample was handled and how the diluent was prepared is to accompany
the result. Several complete dilutions and measurements of the sample can be made to demonstrate that the
method adopted is stable and reproducible.
6.3 Sample dilution
In addition to general practice in sample preparation for particle systems (dilution of particle dispersions)
[18]
, simple dilution can change the chemical composition of the medium and therefore affect the particle
zeta-potential, if special measures are not taken. Dilution can also induce dissolution, which alters both the
surface and the medium. The sample preparation shall follow a procedure such that zeta-potential is not
changed from the original system to the diluted sample.
The sample preparation procedure requires that upon dilution not only do particles and their surfaces
remain identical between the original system and the diluted system, but also that the medium remains
electrochemically identical. Particle surface charge is wholly dependent upon the chemical characteristics
of the dispersion medium. Both the pH and specific ion concentration of the dispersing medium are vital
characteristics to be controlled if concentrated suspensions are to be diluted for measurement. The
conditions that particles are experiencing within a concentrated suspension shall be entirely matched by
the diluent.
This condition is not easy to satisfy if both dilution and surfactant stabilization of the sample are involved.
The sample preparation procedures can affect liquid composition tremendously. It is rather difficult to
adjust the particle concentration for electrophoretic mobility measurements without impacting the physico-
chemical properties of the dispersion medium and the interface. For instance, dispersing amorphous silica
in KNO solution results in a suspension that will be different from the same material dispersed in de-
ionized water with respect to ionic strength. These differences have a considerable impact on the interfacial
properties, such as the zeta-potential.
6.3.1 Sample dilution procedures
In systems relying on electrophoresis with optical detection, particle-particle interactions are minimized
by diluting the sample to an appropriate concentration. In this case, care shall be taken that solvent shock or
other dilution effects do not alter the electrokinetic properties of the sample.
Sample dilution can follow the so-called equilibrium dilution approach, wherein the same liquid as in the
original system is utilized as the diluent. When done properly, equilibrium dilution results in a sample where
the only parameter modified is the particle concentration. Only sample preparation based on equilibrium
dilution yields zeta-potential values that are theoretically identical between the original system and the
diluted sample. Simple dilution using deionized water, for example, is a misleading and generally incorrect
way to prepare samples for zeta-potential measurement.
There are two approaches to the collection of the liquid used for equilibrium dilution. The first consists
of extracting a supernatant using gravitational sedimentation or centrifugation. This supernatant or
“mother liquor” can then be used for diluting the initial sample to the degree that is optimal for the chosen
measurement technique. This method is suitable for large particles with sufficient density contrast. It is not
very convenient for nanoparticles and biological systems with low density contrast. On the other hand, for
emulsions, where a third phase (an emulsifier) stabilizes the normally immiscible oil and aqueous phases,
dilution into a matched ionic background is typical, due to the difficulty of using centrifugation in this case.
Ideally, this preserves the same ionic background in both the concentrated and more dilute forms. This
diluent can be obtained by knowledge of the ionic composition (ions, ionic surfactants) in the dispersant
phase. However, this will not account for species released by the particle phase itself. A third approach,
perhaps more suitable for nano- and bio-colloids is to employ dialysis. Dialysis membranes are required that
are permeable for ions and molecules, but not for colloidal particles, and the process must be validated to
avoid artefacts such as particle or surfactant loss to the membrane.
In some rare cases, samples must be prepared at higher concentrations than the native material. This can
be achieved by initially separating particles from the medium and then re-dispersing them into the same
medium, but at a higher volume fraction. It can also be possible to gently centrifuge the particles to obtain
a more concentrated fraction, after removal of the supernatant phase. This process must be optimized to
mitigate particle loss or agglomeration effects.

Any medium utilized for dilution or for preparing samples must be initially free of particles (at least to the
extent that residual particles can impact the zeta-potential measurement). For relatively “clean” media, one
can use membrane filters (e.g., syringe filters) with a mean pore size smaller than the smallest particles to
be analysed. The hydrophobicity or chemical resistivity of the membrane filter should also be considered.
More complex media may prove more difficult to process. Centrifugation can also be used to achieve this
objective.
6.3.2 Sample stability test
It is always advisable to conduct a series of measurements, sequenced in time, to demonstrate that the sample
is stable. For example, the dissociation of ionic species from the particles in suspension can result in a change
of pH or conductivity over time together with the mobility value. It is recommended that a determination
of pH and/or conductivity of the suspension be conducted before and after each measurement. This can
confirm that the sample is not changing. Any observable instability in the sample represents a further
challenge for analysis. If faced with this problem, it is recommended that rates of change be reported in
addition to absolute values.
It is recommended to conduct a series of measurements at different concentrations if dilution is required.
The effect of particle-particle interactions or other dilution effects can thus be observed. Typically,
hindered movement resulting from particle-particle interactions reduces the apparent motion, shifting the
determined zeta-potential toward the zero-value direction.
6.4 Measurement uncertainty
Normal quality markers for precision (minimum of three consecutive measurements when using optical
[19] [20]
methods or six consecutive measurements when using acoustic methods , under repeatability
conditions or different aliquots of the same starting material) and robustness (e.g., dilution effects, voltage
effects, etc.) apply. Any specification can be "just good enough" and "fit for purpose" noting that a 1 mV
change at 80 mV is not comparable to a 1 mV change at or around 0 mV. Trending results are normally an
indicator of something changing in the system.
Many manufacturers provide result quality and expert advice assistance, and it is obvious to state that these
are ignored at one’s peril.
Adequate signal-to-noise ratio is vital. Poor signal-to-noise ratio often results in poor precision. In many
cases the raw signal data can be inspected and expert assistance sought and utilized. Excessively broad or
multiple peaks are suspicious and always warrant careful investigation. Particle concentrations that are too
high or too low can cause measurement issues, and thus a series of particle concentration often provides
useful insight as to the range within which adequate measurements can be undertaken.
6.5 Sources of error
Zeta-potential measurements are particularly sensitive to cleanliness and the presence of small quantities
of contaminants such as polyvalent ions or leached materials, which will possibly not significantly affect the
conductivity or pH. The quality of any water used for dilution or sample preparation is important. It cannot
be assumed that deionized water from a commercial water treatment system meets the requirements
for zeta-potential measurements; if possible, this water source should be tested independently from the
dispenser (e.g., most commercial zeta-potential instruments allow measurement of conductivity and pH).
The measurement of a certified reference material or secondary measurement materials will confirm
instrument performance and should always be performed if doubts exist. Periodic (e.g., annual) instrument
performance verification by the instrument manufacturer or their representative is strongly recommended
when possible.
6.5.1 Carryover contamination from previous samples
A residue of the previous sample can remain in the cell due to inadequate flushing, unless the cell is of the
disposable or replaceable type. Flushing is possibly not adequate when switching between very high and
very low ion concentrations or distinctly different types of samples. A separate cell kept exclusively for
high ion concentration sample measurements is preferred, or disposable cells, if available, may be used. It

is also recommended to run measurements, in the case of multiple related samples, from low to high ion
concentrations and from low to high pH, in order to avoid carry-over contamination.
6.5.2 Inappropriate sample preparation procedures
Refer to subclause 6.2 for details regarding sample dilution issues. Any glassware or other vessels used to
create a supernatant or equivalent suspending medium shall be clean and free from ionic contamination.
Possible adsorption of sample on the measurement cell surface can also alter measurements and result in
a biased zeta-potential result. One way to circumvent this problem is to condition the cell with the sample
[21]
prior to the measurement .
6.5.3 Inappropriate samples for electrophoretic light scattering measurement
Particles should be suspended in the sample cell and remain in the light beam during the entire
electrophoretic mobility measurement. Therefore, particle density determines the largest particle that can
be measured over a certain time period using a particular method and instrument setup. Capillary cells have
very small distances for particles to travel before they settle out of the measurement zone. For sedimenting
particles, accessible measurement time using a capillary cell will be much shorter than that using a dip cell,
where two plate-electrodes are immersed in a cuvette. Particles also must produce sufficient scattering to
be detected, which then determines the smallest particles at a given concentration that can be measured.
The phase analysis light scattering (PALS) method in electrophoretic light scattering permits the lowest
mobility determination for nanoparticles, since the influence of Brownian motion is considerably reduced
as the PALS processing largely removes the diffusive term from the result. The influence of Brownian
motion can also be empirically removed during processing the data from electrophoretic light scattering
[22]
measurements .
6.5.4 Inappropriate liquid medium
The medium shall be non-absorbing at the wavelength of the laser used. The viscosity cannot be too high;
preferably viscosity (η ) is lower than 10 mPa•s. The medium cannot be significantly volatile or evaporative
o
at the measurement temperature, or the cell used for measurement should be capable of preventing
significant loss of solvent.
6.5.5 Incorrect entries of parameters by the operator
Bias will be introduced when parameters such as permittivity, viscosity, refractive index, temperature,
conductivity, and electric field are incorrectly entered or determined. Ensure that correct parameters and
conditions for the measurement have been entered or selected by the instrument.
It is especially troublesome for non-Newtonian liquids where appropriate values for viscosity become
[23] [24]
unclear. One approach is to use “micro-viscosity” , . According to this concept, particles moving in the
non-Newtonian liquid experience “micro-viscosity” that differs from the “macro-viscosity” value that can be
measured with classical rheological instruments. The value of micro-viscosity would depend on the ratio of
the particle size to the mesh size of the additives that constitute the non-Newtonian liquid. It also depends
on the frequency of the particle motion if AC electric fields are applied to a specific experiment.
There is only one known way for determining micro-viscosity – measuring a dispersion that contains
particles with a known size. The measurement technique must be sensitive to the viscosity value. This
includes gravitational sedimentation, centrifugation, acoustics, and dynamic light scattering. The measured
raw data can be used to back out a viscosity value that would yield the known particle size. Such a viscosity
value can then be used as the “micro-viscosity” input parameter for measuring samples with unknown size
and determining their zeta-potential.
There are several conditions to use this micro-viscosity approach. First, the size range of the samples with
unknown size must be similar to the size that was used for determining micro-viscosity. This will ensure
that the ratio of the particle size to the mesh size does not vary significantly. Another condition is associated
with the frequency of the micro-viscosity measurement. Micro-viscosity is frequency-dependent for non-
Newtonian liquids. Different zeta-potential measurement methods require different values of micro-

viscosity since they function at different frequencies. For instance, the micro-electrophoresis method and the
electrophoretic light scattering (ELS) method require micro-viscosity values measured at zero frequency,
while the electroacoustic method requires micro-viscosity determined in the MHz range. Therefore, for
micro-electrophoresis and ELS, sedimentation or DLS can be used for micro-viscosity measurements. For
[25] [26]
electroacoustics, acoustic particle sizing is used for micro-viscosity measurements , .
6.5.6 Air bubbles
Air bubbles can form during the filling process or during filtration, from dissolved air, or due to
electrochemical reactions, e.g., electrolysis occurring at the electrode surface. Bubbles adhering to the
walls of a capillary cell can distort the electric field leading to uncertainty of the position of the stationary
layer. Bubbles adhering to electrode surfaces can result in an incorrect measurement of conductivity. Gentle
tapping is often sufficient to remove bubbles adhered to the electrodes or capillary surface. Recognizing
their presence, though, is the most important step.
6.5.7 Inappropriate theory for calculating zeta-potential from the measured electrophoretic
mobility
While zeta-potential is calculated from the measurement of electrophoretic mobility, the appropriate theory
and equation to be used for this calculation depends critically upon the nature of particles as well as the
[27]
suspension environment (see for a more complete explanation and various theories). For example, for
electrokinetically soft particles, e.g., hairy particles or emulsion droplets, the zeta-potential derived from
the theories included in commercial instruments can be used for the purpose of comparing different samples
of the same type but should otherwise be used with caution.
6.5.8 Carbon dioxide
Atmospheric CO dissolves in aqueous solution and forms carbonic acid, which dissociates to form protons
+ -
(H ) and bicarbonate ions (HCO ):
(1)
The equilibrium of the reaction in Formula (1) is affected by pH but also changes pH. The system is self-
regulating: For deionized water, the pH shifts to about pH 5.6; this value holds approximately true for any
initial pH between pH 6 and pH 8. Below pH 6, the initial pH is essentially unaffected by CO . Above pH 8,
there is a significant downward shift in pH.
This process also affects ionic strength, which is especially important for systems based on distilled and de-
ionised water. Based on the limiting ionic equivalent conductivities of hydrogen ion and hydroxide ion and
dissociation constant of water, the theoretical value for the electrolytic conductivity of pure water at 25.8 °C
is 0.055 μS/cm.
The absorption of ambient CO by water can cause the electrolytic conductivity to increase by a factor of
[28]
10 to 30, depending on the level of CO in the atmosphere. For instance, it has been stated that : “… the
electrolytic conductivity of pure water equilibrated with atmospheric carbon dioxide can range from 0.7
μS/cm to 1.3 μS/cm depending on atmospheric pressure in the laboratory, giving a standard uncertainty
± 0.2 μS/cm. For a 12 μS/cm solution, this amounts to a relative standard uncertainty in the electrolytic
conductivity of about ± 2 %.”
6.5.9 Effect of the applied electric field on susceptible samples
There are several po
...


ISO/TC 24/SC 4
ISO/CD TS 19997(en)
Secretariat:  BSI
GuidelinesDate: 2026-11-16
Guidance and requirements for good practices in zeta-potential
measurement
Lignes directrices relatives aux bonnes pratiques pour la mesure du potentiel zéta

©
ISO/CD TSDTS 19997:2026(en)
© ISO 2026
All rights reserved. Unless otherwise specified,
This ISO publication is protected by copyright and is owned by ISO and/or its licensors.
The content of this ISO publication is provided under licence, not sold. Use is subject to the applicable licence terms issued
by ISO, an ISO member body, or an authorized third-party distributor.
Except as required in the context of its for implementation or expressly permitted by a separate licence, no part of this
ISO publication may be reproduced or utilized otherwise, distributed, modified, used, or made available in any form or
by any means, – electronic or mechanical, including photocopying, scanning, recording, or posting on internal or external
digital platforms.
Any use beyond the internet or an intranet, without prior written permission. Permission can be requested from either
ISO at the address below or ISO’s member body in the countryscope of the requestergranted rights is prohibited and may
result in legal action.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: + 41 22 749 01 11
E-mailEmail: copyright@iso.org
Website: www.iso.org
Published in Switzerland
iii
ISO/CD TSDTS 19997:2026(en)
Contents
Foreword . v
Introduction . vi
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Symbols . 4
5 Methods for zeta-potential determination . 4
6 Electrophoretic light scattering . 6
6.1 General . 6
6.2 Sampling and sample inspection . 6
6.3 Sample dilution . 6
6.4 Measurement uncertainty . 8
6.5 Sources of error . 8
6.6 Measurement of concentrated samples . 11
7 Colloid vibration current . 13
8 DC streaming potential . 16
8.1 General . 16
8.2 Sample preparation . 17
8.3 Measurement methods . 19
8.4 Measurement conditions . 22
8.5 Applicability of the Smoluchowski equation . 25
8.6 Preventive maintenance . 26
Annex A (informative) Zeta-potential measurement for particles in non-polar media . 27
Annex B (informative) Zeta-potential determination for materials with a flat surface . 28
Bibliography . 33

iv
ISO/CD TSDTS 19997:2026(en)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types of
ISO documents should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent rights
in respect thereof. As of the date of publication of this document, ISO had not received notice of (a) patent(s)
which may be required to implement this document. However, implementers are cautioned that this may not
represent the laterstlatest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held respobsibleresponsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 24, Particle characterization including sieving,
Subcommittee SC 4, Particle characterization.
This first edition of ISO/TS 19997 cancels and replaces ISO/TR 19997:2018.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
v
ISO/CD TSDTS 19997:2026(en)
Introduction
Zeta-potential is the electric potential at the slipping plane of a colloidal particle in suspension or porous
material immersed in liquid, relative to the bulk liquid, which is often used to investigate the isoelectric point
(IEP) and surface adsorption for particles in liquid media, and as an indicator in comparing different samples
regarding electrostatic-dependent dispersion stability. Zeta-potential is not a directly measurable quantity,
but one that is established using an appropriate theory. Furthermore, zeta-potential is not an intrinsic
property of suspended particles; it depends on both particle and medium properties, and how they interact at
the interface. Any variation in the liquid chemical and ionic composition affects this interfacial equilibrium
and, consequently, zeta-potential. Therefore, sample preparation and measurement procedures can both
affect the measurement result. Incorrect conclusions often result from artefacts in sample preparation and
issues arising from measurement procedures, or incorrect application of theoretical models for calculating
zeta-potential from measurement results.
This document provides general guidelines for sample preparation and measurement procedures for the
determination of zeta-potential by optically based electrophoretic mobility measurement, by DC streaming
potential measurement, and electroacoustic measurement.
vi
ISO/CD TSDTS 19997:2026(en)
GuidelinesGuidance and requirements for good practices in zeta-
potential measurement
1 Scope
This document provides information on the zeta-potential measurement operation for applications such as
new product design, optimization of existing products, quality control during processing and/or during usage
of the product.
It does not provide a complete measurement procedure for zeta-potential determination. The information
[15] [19]
provided can help in performing zeta-potential determination according to ISO 13099-1 , ISO 13099-2 ,
[20] [17]
ISO 13099-3 and ISO 13100 the documentary standards ISO 13099-1, ISO 13099-2, ISO 13099-3 and ISO
13100 .
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain
terminology databases for use in standardization at the following addresses:
ISO and IEC maintain terminology databases for use in standardization at the following addresses:IEC
Electropedia: available at
— ISO Online browsing platform: available at https://www.iso.org/obp
— IEC Electropedia: available at https://www.electropedia.org/
3.1
Brownian motion
random movement of particles suspended in a liquid caused by thermal movement of medium molecules
[5]
[SOURCE: ISO 13099-2:2025 [SOURCE: ISO 13099-2:2025,, 3.1.1]]]
3.2
colloid vibration current
CVI, noun
a.c. current generated between two electrodes, placed in a dispersion, if the latter is subjected to an ultrasonic
field
Note 1 to entry: Colloid vibration current is expressed in amperes.
[20]
[SOURCE: ISO 13099-3:2014 ISO 13099-3:2014,, 3.3.1]
3.3
colloid vibration potential
CVU, noun
a.c. potential difference generated between two electrodes, placed in a dispersion, if the latter is subjected to
an ultrasonic field
ISO/CD TSDTS 19997:2026(en)
Note 1 to entry: Colloid vibration potential is expressed in volts.
[20]
[SOURCE: ISO 13099-3:2014 ISO 13099-3:2014,, 3.3.2]
3.4
electric double layer
spatial charge distribution that appears on and at the vicinity of the surface of an object when it is placed in
contact with a liquid
[17]
[SOURCE: ISO 13100:2024 ISO 13100:2024,, 3.1.2]
3.5
electroacoustics
phenomena arising from the coupling between the ultrasound field and electric field in a liquidthatliquid that
contains ions
[15]
[SOURCE: ISO 13099-1:2012 ISO 13099-1:2012,, 2.3]
3.6
electrokinetic potential
zeta-potential, noun
ζ-potential, noun
difference in electric potential between that at the slipping plane and that of the bulk liquid
Note 1 to entry: Electrokinetic potential is expressed in volts.
[15]
[SOURCE: ISO 13099-1:2012 ISO 13099-1:2012,, 2.1.8]
3.7
electroosmosis
electroosmotic flow
motion of liquid through or past a charged surface, e.g. an immobilized set of particles, a porous plug, a
capillary or a membrane, in response to an applied electric field, which is the result of the force exerted by the
applied field on the countercharge ions in the liquid
[15]
[SOURCE: ISO 13099-1:2012 ISO 13099-1:2012,, 2.2.1]
3.8
electrophoresis
movement of charged colloidal particles or polyelectrolytes, immersed in a liquid, under the influence of an
external electric field
[15]
[SOURCE: ISO 13099-1:2012 ISO 13099-1:2012,, 2.2.4]
3.9
electrophoretic mobility
μ, noun
electrophoretic velocity per electric field strength
Note 1 to entry: Electrophoretic mobility is positive if the particles move toward lower potential (negative electrode) and
negative in the opposite case.
Note 2 to entry: Electrophoretic mobility is expressed in metres squared per volt second.
[15]
[SOURCE: ISO 13099-1:2012 ISO 13099-1:2012,, 2.2.5]
ISO/CD TSDTS 19997:2026(en)
3.10
ion vibration current
IVI, noun
a.c. electric current created from different displacement amplitudes in an ultrasound wave due to the
difference in the effective mass or friction coefficient between anion and cation
Note 1 to entry: Ion vibration current is expressed in amperes.
[20]
[SOURCE: ISO 13099-3:2014 13099-3:2014,, 3.3.4]
3.11
isoelectric point
condition of liquid medium, usually the value of pH, that corresponds to zero zeta-potential
[15]
[SOURCE: ISO 13099-1:2012 ISO 13099-1:2012,, 2.1.10]
3.12
permeance
rate of liquid flow per unit area and per unit static pressure differential
Note 1 to entry: Permeance is expressed in metres per Pascal second.
3.13
pore
cavity or channel which is deeper than it is wide, otherwise it is part of the material’s roughness
[9]
[SOURCE: ISO 15901-1:2016 ISO 15901-1:2016,, 3.5]
3.14
porosity
ratio of the volume of the accessible pores and voids to the bulk volume occupied by an amount of the solid
[9]
[SOURCE: ISO 15901-1:2016 ISO 15901-1:2016,, 3.27]
3.15
sedimentation potential
U , noun
sed
potential difference sensed by two electrodes placed some vertical distance apart in a dispersion in which
particles are sedimenting under the effect of gravity
Note 1 to entry: When the sedimentation is produced by a centrifugal field, the phenomenon is called centrifugation
potential.
Note 2 to entry: Sedimentation potential is expressed in volts.
[15]
[SOURCE: ISO 13099-1:2012 ISO 13099-1:2012,, 2.2.7]
3.16
slipping plane
shear plane, noun
abstract plane in the vicinity of the interface between liquid and surface where liquid starts to slide relative to
the surface under influence of a shear stress
[5]
[SOURCE: ISO 13099-2:2025 ISO 13099-2:2025,, 3.1.10]
ISO/CD TSDTS 19997:2026(en)
3.17
streaming current
I , noun
str
current through a porous body resulting from the motion of fluid under an applied pressure gradient
Note 1 to entry: Streaming current is expressed in amperes.
[15]
[SOURCE: ISO 13099-1:2012 ISO 13099-1:2012,, 2.2.8]
3.18
streaming potential
U , noun
str
potential difference at zero electric current, caused by the flow of liquid under a pressure gradient through a
capillary, plug, diaphragm or membrane
Note 1 to entry: Streaming potentials are created by charge accumulation caused by the flow of counterchargescounter
charges inside capillaries or pores.
Note 2 to entry: Streaming potential is expressed in volts.
[15]
[SOURCE: ISO 13099-1:2012 ISO 13099-1:2012,, 2.2.10]
3.19
streaming potential coupling coefficient
U /ΔP, noun
str
electrokinetic phenomenon determined by the slope of the linear dependence of the measured streaming
potential on an applied pressure gradient
Note 1 to entry: Streaming potential coupling coefficient is expressed in volts per pascal.
[17]
[SOURCE: ISO 13100:2024 ISO 13100:2024,, 3.2.8]
4 Symbols
K Electricelectric conductivity
P pressure
U Streamingstreaming potential
str
ε Vacuumvacuum permittivity
o
ε relative permittivity of the medium
m
ε eta dynamic viscosity of the medium
m
μ electrophoretic mobility
ζ electrokinetic potential, zeta-potential
5 Methods for zeta-potential determination
Zeta-potential (ζ) is the electric potential at a shearslipping plane that separates the mobile solvent from
solvent molecules that associate with the surfaces of particles, fibres, porous material, or solids with a planar
surface (see Annex BAnnex B).). Zeta-potential is not an intrinsic material property; it depends on the
interaction between the surface of the particle or the solid material and the liquid phase in which the particle
is dispersed, or the solid material is in contact with. Any variation of the liquid chemical and ionic composition
[10] [11] [12]
affects this interaction and, consequently, affect zeta-potential , , ,,.
ISO/CD TSDTS 19997:2026(en)
Zeta-potential is frequently used to predict the stability of a suspension or the adhesion of suspended particles
onto macroscopic surfaces (e.g., cellulose fibres, membranes). This is because interaction between particles
or between particles and surfaces is often governed by the ion distribution in the diffuse layer, which is closely
related to zeta-potential. Whenever electrostatic forces dominate interactions between particles or between
[13]
particles and surfaces, zeta-potential is the principal system parameter to evaluate these interactions .
Repulsion requires high surface charges of equal sign, whereas attraction occurs in the absence of surface
charge or for oppositely charged or “patchy” surfaces containing both negatively and positively charged
domains. High zeta-potential absolute values cause strong repulsion between dispersed particles and, thus,
favour the stabilisation of colloidal suspensions. This effect is even more pronounced for thick double layers
in low electrolyte content. In contrast, low zeta-potential absolute values (positive or negative), zeta-
potentials of opposite sign (opposite polarity), or high electrolyte concentrations (thin double layers), can
promote agglomeration. Hence, zeta-potential can be principally employed to predict the suspension stability,
which is frequently determined as a function of the pH and/or the concentration of indifferent electrolytes
[14] [15]
and surface-active ionic species (e.g., ionic surfactants, multi-valent ions and polyelectrolytes) , ),.
The perception that there is a universally valid critical zeta-potential value that defines the transition from
unstable to stable suspensions has been proven only in limited applications. Zeta-potential values must be
used carefully when evaluating the suspension stability. It is recommended that in formulation work to predict
stability, a second measurand (e.g., size distribution, turbidity, viscosity, etc.) can be monitored and correlated
to verify the conclusion derived from zeta-potential measurement.
The zeta-potential analysis for this variety of different materials requires different measurement techniques
(see Table 1cf. Table 1).). Zeta-potential can be probed by imposing a relative motion between bulk solvent
and particle. Zeta-potential measurements on colloidal dispersion are frequently conducted via either
electrophoresis or electroacoustics for applications under different sample conditions (e.g., diameter range
-4 [16]
% to 40 %) .
from nanometre up to tens of micrometres with particle volume fraction from roughly 10
The determination of the zeta-potential for porous media (consolidated porous body, plug of granular
particles, or plug of fibres) follows the same principle of a relative motion between the bulk solvent and the
respective porous material surface via either DC or AC streaming potential and streaming current
[17]
measurements .
Table 1 — Appropriate methods for zeta-potential determination of particles and porous media
Driving force System type DC, Low frequency High frequency (MHz)
(kHz)
Electric particulates Electrophoretic mobility Electrokinetic Sonic sonic
a
Amplitude (see footnote 2)
porous, flat Electroosmotic flow (see Electro-seismic effect (see
a,b a,b
footnotes 1 and 2) footnotes 1 and 2)
Mechanical, gravitational particulates Sedimentation potential Colloid Vibration
a,b
(see footnotes 1 and 2) Currentvibration current
porous, flat Streaming potential, Seismo-electric effect (see
a
streaming current footnote 2)
a
This method is not discussed in this document.
b
This method is not accessible through a commercially available analytical instrument.
1)2)
1)
This method is not accessible through a commercially available analytical instrument.

2)
This method is not discussed in this document.
ISO/CD TSDTS 19997:2026(en)
6 Electrophoretic light scattering

6.1 General
Electrophoretic light scattering (ELS) is an indirect ensemble method for measuring electrophoretic mobility
via the Doppler shifts in scattered light. In an ELS experiment, coherent incident light illuminates dispersed
particles in a liquid that are subjected to an applied electric field. Charged particles move towards either the
anode or the cathode, depending on the sign of their net charge. Because of the motion, the frequency of
scattered light from particles is shifted due to the Doppler effect. From the frequency shift distribution, the
particle electrophoretic mobility distribution can be determined.
6.2 Sampling and sample inspection
The electrophoretic mobility (μ) measured in a sample is only valid for a batch of material if the test sample is
representative of that batch and has been sampled adequately.
The material to be analysed should be inspected to ensure the particles have been dispersed adequately
without any sedimentation occurring upon standing for a period relevant to the measurement time. If particles
sediment during measurement, measurement using optical methods mayis potentially not be appropriate
since particles remaining in the laser beam maypossibly do not represent the whole sample (e.g., with
polydisperse samples, large particles will settle differentially resulting in a biased measurement of the smaller
size particles).
Considerable care shall be exercised during sample preparation to avoid changing the electrophoretic mobility
of the sample to be tested. Labware that comes into direct contact with the sample, such as a glass beaker or
syringe, may adsorb specific ions from the medium or add residual contaminants to the sample that remain
from a prior cleaning process or from production of the labware itself. Disposable plastic preparation beakers
and pipettes are generally preferred, so long as they are chemically compatible with the sample.
A detailed report of how precisely the sample was handled and how the diluent was prepared is to accompany
the result. Several complete dilutions and measurements of the sample can be made to demonstrate that the
method adopted is stable and reproducible.
6.3 Sample dilution
In addition to general practice in sample preparation for particle systems (dilution of particle
[18]
dispersions) ),, simple dilution can change the chemical composition of the medium and therefore affect
the particle zeta-potential, if special measures are not taken. Dilution can also induce dissolution, which alters
both the surface and the medium. The sample preparation shallnshall follow a procedure such that zeta-
potential is not changed from the original system to the diluted sample.
The sample preparation procedure requires that upon dilution not only do particles and their surfaces remain
identical between the original system and the diluted system, but also that the medium remains
electrochemically identical. Particle surface charge is wholly dependent upon the chemical characteristics of
the dispersion medium. Both the pH and specific ion concentration of the dispersing medium are vital
characteristics to be controlled if concentrated suspensions are to be diluted for measurement. The conditions
that particles are experiencing within a concentrated suspension shall be entirely matched by the diluent.
This condition is not easy to satisfy if both dilution and surfactant stabilization of the sample are involved. The
sample preparation procedures can affect liquid composition tremendously. It is rather difficult to adjust the
particle concentration for electrophoretic mobility measurements without impacting the physico-chemical

ISO/CD TSDTS 19997:2026(en)
properties of the dispersion medium and the interface. For instance, dispersing amorphous silica in KNO
solution results in a suspension that will be different from the same material dispersed in de-ionized water
with respect to ionic strength. These differences have a considerable impact on the interfacial properties, such
as the zeta-potential.
6.3.1 Sample dilution procedures
In systems relying on electrophoresis with optical detection, particle-particle interactions are minimized by
diluting the sample to an appropriate concentration. In this case, care shall be taken that solvent shock or
other dilution effects do not alter the electrokinetic properties of the sample.
Sample dilution can follow the so-called equilibrium dilution approach, wherein the same liquid as in the
original system is utilized as the diluent. When done properly, equilibrium dilution results in a sample where
the only parameter modified is the particle concentration. Only sample preparation based on equilibrium
dilution yields zeta-potential values that are theoretically identical between the original system and the
diluted sample. Simple dilution using deionized water, for example, is a misleading and generally incorrect
way to prepare samples for zeta-potential measurement.
There are two approaches to the collection of the liquid used for equilibrium dilution. The first consists of
extracting a supernatant using gravitational sedimentation or centrifugation. This supernatant or “mother
liquor” can then be used for diluting the initial sample to the degree that is optimal for the chosen
measurement technique. This method is suitable for large particles with sufficient density contrast. It is not
very convenient for nanoparticles and biological systems with low density contrast. On the other hand, for
emulsions, where a third phase (an emulsifier) stabilizes the normally immiscible oil and aqueous phases,
dilution into a matched ionic background is typical, due to the difficulty of using centrifugation in this case.
Ideally, this preserves the same ionic background in both the concentrated and more dilute forms. This diluent
can be obtained by knowledge of the ionic composition (ions, ionic surfactants) in the dispersant phase.
However, this will not account for species released by the particle phase itself. A third approach, perhaps more
suitable for nano- and bio-colloids is to employ dialysis. Dialysis membranes are required that are permeable
for ions and molecules, but not for colloidal particles, and the process must be validated to avoid artefacts such
as particle or surfactant loss to the membrane.
In some rare cases, there is a need to prepare samples must be prepared at higher concentrations than the
native material. This can be achieved by initially separating particles from the medium and then re-dispersing
them into the same medium, but at a higher volume fraction. It maycan also be possible to gently centrifuge
the particles to obtain a more concentrated fraction, after removal of the supernatant phase. This process must
be optimized to mitigate particle loss or agglomeration effects.
Any medium utilized for dilution or for preparing samples must be initially free of particles (at least to the
extent that residual particles can impact the zeta-potential measurement). For relatively “clean” media, one
can use membrane filters (e.g., syringe filters) with a mean pore size smaller than the smallest particles to be
analysed. The hydrophobicity or chemical resistivity of the membrane filter should also be considered. More
complex media may prove more difficult to process. Centrifugation can also be used to achieve this objective.
6.3.2 Sample stability test
It is always advisable to conduct a series of measurements, sequenced in time, to demonstrate that the sample
is stable. For example, the dissociation of ionic species from the particles in suspension can result in a change
of pH or conductivity over time together with the mobility value. It is recommended that a determination of
pH and/or conductivity of the suspension be conducted before and after each measurement. This can confirm
that the sample is not changing. Any observable instability in the sample represents a further challenge for
analysis. If faced with this problem, then it is recommended that rates of change be reported in addition to
absolute values.
ISO/CD TSDTS 19997:2026(en)
It is recommended to conduct a series of measurements at different concentrations if dilution is required. The
effect of particle-particle interactions or other dilution effects can thus be observed. Typically, hindered
movement resulting from particle-particle interactions reduces the apparent motion, shifting the determined
zeta-potential toward the zero-value direction.
6.4 Measurement uncertainty
Normal quality markers for precision (minimum of three consecutive measurements when using optical
[19] [20]
methods or six consecutive measurements when using acoustic methods ,, under repeatability
conditions or different aliquots of the same starting material) and robustness (e.g., dilution effects, voltage
effects, etc.) apply. Any specification can be ‘"just good enough’enough" and ‘"fit for purpose’purpose" noting
that a 1 mV change at 80 mV is not comparable to a 1 mV change at or around 0 mV. Trending results are
normally an indicator of something changing in the system.
Many manufacturers provide result quality and expert advice assistance, and it is obvious to state that these
are ignored at one’s peril.
Adequate signal-to-noise ratio is vital. Poor signal-to-noise ratio often results in poor precision. In many cases
the raw signal data can be inspected and expert assistance sought and utilized. Excessively broad or multiple
peaks are suspicious and always warrant careful investigation. Particle concentrations that are too high or too
low can cause measurement issues, and thus a series of particle concentration often provides useful insight as
to the range within which adequate measurements can be undertaken.
6.5 Sources of error
Zeta-potential measurements are particularly sensitive to cleanliness and the presence of small quantities of
contaminants such as polyvalent ions or leached materials, which maywill possibly not significantly affect the
conductivity or pH. The quality of any water used for dilution or sample preparation is important. It cannot be
assumed that deionized water from a commercial water treatment system meets the requirements for zeta-
potential measurements; if possible, this water source should be tested independently from the dispenser
(e.g., most commercial zeta-potential instruments allow measurement of conductivity and pH). The
measurement of a certified reference material or secondary measurement materials will confirm instrument
performance and should always be performed if doubts exist. Periodic (e.g., annual) instrument performance
verification by the instrument manufacturer or their representative is strongly recommended when possible.
6.5.1 Carryover contamination from previous samples
A residue of the previous sample can remain in the cell due to inadequate flushing, unless the cell is of the
disposable or replaceable type. Flushing is possibly not adequate when switching between very high and very
low ion concentrations or distinctly different types of samples. A separate cell kept exclusively for high ion
concentration sample measurements is preferred, or disposable cells, if available, may be used. It is also
recommended to run measurements, in the case of multiple related samples, from low to high ion
concentrations and from low to high pH, in order to avoid carry-over contamination.
6.5.2 Inappropriate sample preparation procedures
Refer to subclause 6.26.2 for details regarding sample dilution issues. Any glassware or other vessels used to
create a supernatant or equivalent suspending medium shall be clean and free from ionic contamination.
Possible adsorption of sample on the measurement cell surface can also alter measurements and result in a
biased zeta-potential result. One way to circumvent this problem is to condition the cell with the sample prior
[21]
to the measurement .
ISO/CD TSDTS 19997:2026(en)
6.5.3 Inappropriate samples for electrophoretic light scattering measurement
Particles should be suspended in the sample cell and remain in the light beam during the entire electrophoretic
mobility measurement. Therefore, particle density determines the largest particle that can be measured over
a certain time period using a particular method and instrument setup. Capillary cells have very small distances
for particles to travel before they settle out of the measurement zone. For sedimenting particles, accessible
measurement time using a capillary cell will be much shorter than that using a dip cell, where two plate-
electrodes are immersed in a cuvette. Particles also must produce sufficient scattering to be detected, which
then determines the smallest particles at a given concentration that can be measured.
The phase analysis light scattering (PALS) method in electrophoretic light scattering permits the lowest
mobility determination for nanoparticles, since the influence of Brownian motion is considerably reduced as
the PALS processing largely removes the diffusive term from the result. The influence of Brownian motion can
also be empirically removed during processing the data from electrophoretic light scattering
[22]
measurements .
6.5.4 Inappropriate liquid medium
The medium shall be non-absorbing at the wavelength of the laser used. The viscosity cannot be too high;
preferably viscosity (η ) is lower than 10 mPa•s. The medium cannot be significantly volatile or evaporative
o
at the measurement temperature, or the cell used for measurement should be capable of preventing significant
loss of solvent.
6.5.5 Incorrect entries of parameters by the operator
Bias will be introduced when parameters such as permittivity, viscosity, refractive index, temperature,
conductivity, and electric field are incorrectly entered or determined. Ensure that correct parameters and
conditions for the measurement have been entered or selected by the instrument.
It is especially troublesome for non-Newtonian liquids where appropriate values for viscosity become unclear.
[23] [24]
One approach is to use “micro-viscosity” , ”,. According to this concept, particles moving in the non-
Newtonian liquid experience “micro-viscosity” that differs from the “macro-viscosity” value that can be
measured with classical rheological instruments. The value of micro-viscosity would depend on the ratio of
the particle size to the mesh size of the additives that constitute the non-Newtonian liquid. It also depends on
the frequency of the particle motion if AC electric fields are applied to a specific experiment.
There is only one known way for determining micro-viscosity – measuring a dispersion that contains particles
with a known size. The measurement technique needs tomust be sensitive to the viscosity value. This includes
gravitational sedimentation, centrifugation, acoustics, and dynamic light scattering. The measured raw data
can be used to back out a viscosity value that would yield the known particle size. Such a viscosity value can
then be used as the “micro-viscosity” input parameter for measuring samples with unknown size and
determining their zeta-potential.
There are several conditions to use this micro-viscosity approach. First, the size range of the samples with
unknown size needs tomust be similar to the size that was used for determining micro-viscosity. This will
ensure that the ratio of the particle size to the mesh size does not vary significantly. Another condition is
associated with the frequency of the micro-viscosity measurement. Micro-viscosity is frequency-dependent
for non-Newtonian liquids. Different zeta-potential measurement methods would require different values of
micro-viscosity since they function at different frequencies. For instance, the micro-electrophoresis method
and the electrophoretic light scattering (ELS) method require micro-viscosity values measured at zero
frequency, while the electroacoustic method requires micro-viscosity determined in the MHz range.
Therefore, for micro-electrophoresis and ELS, sedimentation or DLS can be used for micro-viscosity
measurements. For electroacoustics, acoustic particle sizing is used for micro-viscosity
[25] [26]
measurements , ,.
ISO/CD TSDTS 19997:2026(en)
6.5.6 Air bubbles
Air bubbles can form during the filling process or during filtration, from dissolved air, or due to
electrochemical reactions, e.g., electrolysis occurring at the electrode surface. Bubbles adhering to the walls of
a capillary cell can distort the electric field leading to uncertainty of the position of the stationary layer.
Bubbles adhering to electrode surfaces can result in an incorrect measurement of conductivity. Gentle tapping
is often sufficient to remove bubbles adhered to the electrodes or capillary surface. Recognizing their
presence, though, is the most important step.
6.5.7 Inappropriate theory for calculating zeta-potential from the measured electrophoretic
mobility
While zeta-potential is calculated from the measurement of electrophoretic mobility, the appropriate theory
and equation to be used for this calculation depends critically upon the nature of particles as well as the
[27]
suspension environment (see for a more complete explanation and various theories). For example, for
electrokinetically soft particles, e.g., hairy particles or emulsion droplets, the zeta-potential derived from the
theories included in commercial instruments can be used for the purpose of comparing different samples of
the same type but should otherwise be used with caution.
6.5.8 Carbon dioxide
Atmospheric CO dissolves in aqueous solution and forms carbonic acid, which dissociates to form protons
+ -
(H ) and bicarbonate ions (HCO ):
+ −
𝐶𝐶𝐶𝐶 +𝐻𝐻𝐶𝐶⇔𝐻𝐻𝐶𝐶𝐶𝐶 ⇔𝐻𝐻 +𝐻𝐻𝐶𝐶𝐶𝐶 (1)
2(𝑎𝑎𝑎𝑎) 2 2 3(𝑎𝑎𝑎𝑎) 3
The equilibrium of the reaction in Formula (1)(1) is affected by pH but also changes pH. The system is self-
regulating: For deionized water, the pH shifts to about pH 5.6; this value holds approximately true for any
initial pH between pH 6 and pH 8. Below pH 6, the initial pH is essentially unaffected by CO . Above pH 8, there
is a significant downward shift in pH.
This process also affects ionic strength, which is especially important for systems based on distilled and de-
ionised water. Based on the limiting ionic equivalent conductivities of hydrogen ion and hydroxide ion and
dissociation constant of water, the theoretical value for the electrolytic conductivity of pure water at 25.8° °C
is 0.055 μS/cm.
The absorption of ambient CO by water can cause the electrolytic conductivity to increase by a factor of 10
[28]
to 30, depending on the level of CO in the atmosphere. For instance, it has been stated that :: “… the
electrolytic conductivity of pure water equilibrated with atmospheric carbon dioxide can range from 0.7
μS/cm to 1.3 μS/cm depending on atmospheric pressure in the laboratory, giving a standard uncertainty ± 0.2
μS/cm. For a 12 μS/cm solution, this amounts to a relative standard uncertainty in the electrolytic conductivity
of about ± 2 %.”
6.5.9 Effect of the applied electric field on susceptible samples
There are several potential adverse effects due to the application of the electric field during electrophoretic
mobility measurements. One such effect is Joule or resistive heating, an effect that increases with the
conductivity of the medium. Joule heating can be mitigated by following the manufacturer’s recommendations
for an appropriate conductivity range or by using cells designed for high conductivity media. High conductivity
typically means aqueous media with an ionic strength significantly above about 0.1 mol/L. Joule heating can
produce both temperature increases and a temperature gradient, both of which would impact the
electrophoretic and electroosmotic flow during zeta-potential measurement.
Another significant issue related to the passage of current through the sample is the potential denaturation of
susceptible samples, such as proteins and protein-like biomolecules (e.g., DNA), including samples (e.g.,
particles) that have biomolecular coatings or other susceptible coatings on their surface. The redox
ISO/CD TSDTS 19997:2026(en)
degradation in the electric field occurs at the electrode surface and maycan be affected by the electrode
material itself; for instance, gold surfaces are highly reactive toward proteins.
Redox related degradation typically exhibits characteristic and observable effects during zeta-potential
measurements, which, if present, recommends further investigation. One observable symptom is a time
dependent increase in hydrodynamic size. Associated with this increase is a drift toward more negative zeta-
potential values (typically), especially for proteinaceous materials. The size increase is due to aggregation
induced by degradation of the sample or its surface coating. For instance, the appearance of a visible black
precipitate is common for gold nanoparticles that are susceptible to redox induced degradation (e.g., citrate
stabilized particles). The appearance of any visible blackening or “growth” at or below the electrode surface
is a strong indication of electrolytic degradation.
Several potential solutions to the degradation or denaturation problem can be considered. These include
reducing the time that the field is applied, applying a reduced electric field (maycan only be possible with
appropriate cell configuration, e.g., dip cells), using short bursts of applied voltage to minimize the "rate" of
denaturation, using a less reactive electrode material (e.g., palladium instead of gold), or simultaneously
monitoring the size and stopping measurements when a significant change/trend is observed. These steps can
mitigate or slow the degradation problem.
The only solution that can eliminate the problem involves separating the susceptible analyte from the
electrode surface by means of a so-called diffusion barrier (note, this approach is only viable if used in a closed
capillary type cell, it will not work in a dip cell). In this case, the capillary is first filled with a buffer matching
the analyte me
...