Respiratory protective devices — Terms, definitions, graphical symbols and units of measurement

ISO 16972:2010 is applicable to respiratory protective devices. It defines commonly used terms and specifies units of measurement to achieve a uniform interpretation and to prevent ambiguous use. It indicates graphical symbols that may be required to be placed on respiratory protective devices (RPD) or parts of RPD or instruction manuals, in order to instruct the person(s) using the RPD about its operation.

Appareils de protection respiratoire — Termes, définitions, symboles graphiques et unités de mesure

L'ISO 16972:2010 s'applique aux appareils de protection respiratoire. Elle définit les termes d'usage courant et spécifie les unités de mesure afin d'uniformiser les interprétations et d'éviter les ambiguïtés. Elle indique les symboles graphiques devant, le cas échéant, être apposés sur les appareils de protection respiratoire (APR) ou sur certaines parties de ces appareils ou pouvant figurer dans les manuels d'instruction destinés à former la ou les personnes utilisant les APR au fonctionnement de ces appareils.

General Information

Status
Withdrawn
Publication Date
07-Mar-2010
Withdrawal Date
07-Mar-2010
Current Stage
9599 - Withdrawal of International Standard
Completion Date
10-Mar-2020
Ref Project

Relations

Buy Standard

Standard
ISO 16972:2010 - Respiratory protective devices -- Terms, definitions, graphical symbols and units of measurement
English language
37 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 16972:2010 - Appareils de protection respiratoire -- Termes, définitions, symboles graphiques et unités de mesure
French language
41 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 16972
First edition
2010-03-15


Respiratory protective devices — Terms,
definitions, graphical symbols and units
of measurement
Appareils de protection respiratoire — Termes, définitions, symboles
graphiques et unités de mesure




Reference number
ISO 16972:2010(E)
©
ISO 2010

---------------------- Page: 1 ----------------------
ISO 16972:2010(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.


COPYRIGHT PROTECTED DOCUMENT


©  ISO 2010
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland

ii © ISO 2010 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 16972:2010(E)
Contents Page
Foreword .iv
1 Scope.1
2 Normative references.1
3 Terms and definitions .1
4 Graphical symbols for use on RPD .12
4.1 Introduction.12
4.2 Examples of how graphical symbols may be used .13
4.2.1 See information supplied by the manufacturer.13
4.2.2 End of shelf life.13
4.2.3 Temperature range of storage conditions .13
4.2.4 Maximum humidity of storage conditions .13
5 Units of measurement.13
5.1 Units.13
Annex A (informative) Terms and definitions referring to respiratory protective devices in current
national standards, regulations or other national contexts.14
Annex B (informative) Abbreviations used .36
Bibliography.37

© ISO 2010 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 16972:2010(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 16972 was prepared by Technical Committee ISO/TC 94, Personal safety — Protective clothing and
equipment, Subcommittee SC 15, Respiratory protective devices.


iv © ISO 2010 – All rights reserved

---------------------- Page: 4 ----------------------
INTERNATIONAL STANDARD ISO 16972:2010(E)

NOTE The terms are listed in alphabetical order.
Terms which refer to current RPD are not listed in these
definitions because they are design related and are
Respiratory protective
described in Annex A. Bold type used within a definition
identifies terms defined elsewhere in this list of preferred
devices — Terms, definitions,
terms.
graphical symbols and units
3.1
of measurement
abrasion resistance
ability of an RPD and/or its components to
withstand degradation from abrasive effects (e.g.
scratch, scrape, scuff)
1 Scope
3.2
abrasive blasting respiratory protective device
This International Standard is applicable to
device designed to protect the wearer from
respiratory protective devices. It defines commonly inhalation of, impact of, and abrasion by materials
used terms and specifies units of measurement to
used or generated in abrasive blasting
achieve a uniform interpretation and to prevent
ambiguous use. It indicates graphical symbols that
3.3
may be required to be placed on respiratory
accessory
protective devices (RPD) or parts of RPD or
item, or items, that are attached to the RPD that
instruction manuals, in order to instruct the
are not necessary for the RPD to meet the
person(s) using the RPD about its operation.
requirements of the ISO RPD performance
standard and do not compromise its protection
3.4
2 Normative references
adequacy assessment
selection method identifying RPD able to reduce
The following referenced documents are
the wearer’s hazard exposure to acceptable levels
indispensable for the application of this document.
For dated references, only the edition cited applies.
3.5
For undated references, the latest edition of the
aerodynamic diameter
referenced document (including any amendments)
diameter of a unit density sphere having the same
applies.
settling velocity as the particle in question
ISO 7000:2004, Graphical symbols for use on
3.6
equipment — Index and synopsis
aerosol
suspension of solid, liquid or solid and liquid
1)
IEC 80416-1 , Basic principles for graphical
particles in a gaseous medium
symbols for use on equipment — Part 1: Creation
of graphical symbols for registration
3.7
aerosol penetration
2)
ISO 80416-2 , Basic principles for graphical
ability of particles to pass through a particle
symbols for use on equipment — Part 2: Form and
filtering material
use of arrows
3.8
air flow resistance
3 Terms and definitions
pressure difference between upstream and
downstream locations caused by the flow of air
For the purposes of this document, the following
through parts and components of RPD such as, an
terms and definitions apply.
exhalation valve, inhalation valve, filter(s), and
tube, etc.

1) Cancels and replaces ISO 3461-1:1988.
2) Cancels and replaces ISO 4196:1984.
© ISO 2010 – All rights reserved 1

---------------------- Page: 5 ----------------------
ISO 16972:2010(E)
3.9 3.18
air-purifying respiratory protective device body harness
device in which ambient air is passed through an means to enable a wearer to wear certain
air-purifying element(s) that remove(s) the components of an RPD on the body
contaminant(s)
3.19
NOTE Air is passed through the air-purifying
breakthrough concentration
element by means of the breathing action or by a blower.
concentration of test gas in effluent air at which a
gas filter undergoing a gas filter capacity test is
3.10
deemed exhausted
ambient air bypass
means to enable the wearer to breathe the
3.20
ambient atmosphere before entering and after
breakthrough curve
leaving a hazardous atmosphere
graph for gas filter(s) showing the relationship
between effluent concentration of the test
3.11
substance versus time of gas filter(s)
ambient air system
device used to deliver ambient air at a low
3.21
pressure directly to an atmosphere supplying RPD
breakthrough time
(manually or power assisted)
time from the start of a gas filter capacity test to
the time when the breakthrough concentration
3.12
has been reached in effluent air under the defined
ambient atmosphere
conditions
air surrounding the RPD wearer
3.22
3.13
breakthrough time curve
ambient concentration
graph showing the relationship between test
concentration of a compound in the air surrounding
concentration and breakthrough time for gas
the RPD wearer
filter(s)
3.14
3.23
ambient laboratory conditions
breathable gas
atmosphere where the temperature is between
mixtures of gases that are suitable for respiration
16 °C and 32 °C and the relative humidity is
without adverse effects to health
between 20 % and 80 %
3.24
3.15
breathable gas cylinder
atmospheric contaminant
integral part of the RPD that contains the
potentially harmful substance that is present in
breathable gas supply
unacceptably high concentration in the ambient air,
and to which workers may be exposed in their
3.25
working environment
breathable gas quality
composition of a breathable gas as defined in
3.16
relevant standards
atmospheric dew point
temperature at which moisture begins to condense
3.26
from a gas as the gas is cooled at standard
breath cycle
atmospheric pressure. (1 013,25 hPa)
time period comprised of one inhalation and one
exhalation sequence
3.17
biological monitoring
3.27
analysis of exhaled air, a biological fluid (e g.,
breathing bag
urine, blood, perspiration), or a body tissue (e g.,
component of an RPD which compensates for
hair, nails) to assess the extent to which an
variations in the breathable gas supply or demand
individual has been exposed to a
and provides for peak inhalation flow requirements
contaminant/hazard
2 © ISO 2010 – All rights reserved

---------------------- Page: 6 ----------------------
ISO 16972:2010(E)
3.28 3.36
breathing gas regeneration char length
process whereby an RPD absorbs carbon dioxide length of brittle residue found when a fabric or
in exhaled gas and delivers oxygen, controls water material is exposed to thermal energy
vapour and temperature of gas to be rebreathed
3.37
3.29 checking device
breathing machine characteristic of RPD to enable the wearer to
ventilation machine that simulates respiratory verify, before use or periodically during use, that
ventilation by using waveforms, which can be the manufacturer’s minimum design conditions are
sinusoidal or representative of the inhalation and met
exhalation cycle
3.38
NOTE See also metabolic simulator.
cleaning/disinfection resistance
ability of the device to withstand cleaning and
3.30
disinfection processes defined by the manufacturer
breathing peak resistance
maximum differential pressure of an RPD during
3.39
inhalation (inhalation peak resistance) or
clogging
exhalation (exhalation peak resistance)
accumulation of particles on a filter with a
consequent increase in its resistance to flow
3.31
breathing resistance
3.40
pressure differential between upstream and
combination filter
downstream location caused by an RPD to the
filter intended to remove dispersed solid and/or
flow of breathable gas during inhalation (inhalation
liquid particles and specified gases and vapours
resistance) or exhalation (exhalation resistance)
from the flow of air passing through it
3.32
3.41
BTPS
combined RPD
body temperature pressure saturated
RPD which are capable to operate in either filtering
standard condition for the expression of ventilation
or breathable gas supply mode
parameters
3.42
EXAMPLE Body temperature (37 °C),atmospheric
communication performance
pressure (1 013,25 hPa) and saturated air (vapour
ability of wearer to communicate face to face with
pressure = 62,66 hPa).
others at a given distance
3.33
3.43
buddy breathing
compatibility
practice that enables a second person to
ability of RPD to be used in conjunction with other
simultaneously share the same breathable gas
PPE
supply as that of the wearer of such RPD while
both persons are attempting to move to a safe
3.44
location
competent person
person with suitable and sufficient experience and
3.34
with practical and theoretical knowledge of the
bypass valve
elements of an RPD programme for which (s)he is
component part of an RPD, which is furnished as
responsible
an emergency manual valve to supply necessary
breathable gas when the ordinary supply path is
3.45
out of order
confined space
area with limited access, as described in national
3.35
regulations, which requires special considerations
CO concentration limits
2
for entry
maximum allowed concentration of carbon dioxide
within inhaled breathable gas
© ISO 2010 – All rights reserved 3

---------------------- Page: 7 ----------------------
ISO 16972:2010(E)
3.46 3.57
continuous flow valve dust
control valve which provides the wearer of a aerosol consisting of mechanically produced solid
breathable gas-supplying RPD with breathable particles derived from the breaking up of larger
gas and allows the wearer to regulate a particles ranging from submicroscopic to
continuous air flow within prescribed limits macroscopic
NOTE See also fume and smoke.
3.47
count median diameter
CMD 3.58
emergency breathing component
particle size of a particle distribution for which one-
half the total number of particles are larger and component of the RPD that comes into operation
when the normally operating mode of the device is
one-half are smaller
not functioning
3.48
NOTE It provides an adequate level of protection
dead space
for a period to enable the device wearer to exit the work
space in which exhaled gas has not been purged
area, unassisted, to a place of safety.
and is subject to being rebreathed
3.59
3.49
electromagnetic compatibility
demountable parts
EMC
parts of the device that are designed to be
ability of a device, unit of equipment or system to
disconnected and reconnected by hand, without
function satisfactorily in its electromagnetic
using tools
environment without introducing intolerable
electromagnetic disturbances to anything in that
3.50
environment
design duration
length of time specified by the manufacturer for a
3.60
device in which the design conditions (e.g. flow
end of battery life
rate) are met
lowest capacity level of a battery which still allows
a proper continuous function of the RPD
3.51
dew point
3.61
temperature of air at a specified pressure when
end of life cycle indicator
condensation of water will occur
system that indicates the end of the overall life of
an RPD
3.52
doffing
3.62
process of removing or taking off the RPD
end-of-service-life indicator
effectively
ESLI
system that warns the wearer of a gas filtering
3.53
RPD of the approach of the end of adequate
donning
respiratory protection
process of putting on the RPD effectively
3.63
3.54
environment
drip
potential hazardous area in which the RPD is to be
to run or fall in drops or blobs
used
3.55
3.64
dummy head
ergonomic factors/parameters
fixture simulating human heads, used in testing
all aspects of the RPD that are intended to
RPD.
maximize the wearer’s ability to perform their tasks
while minimizing wearer fatigue and discomfort
3.56
durability
capability of the device to withstand all usage
stress factors without degradation of performance
or integrity
4 © ISO 2010 – All rights reserved

---------------------- Page: 8 ----------------------
ISO 16972:2010(E)
3.65 3.75
escape RPD filtering device
respiratory protective device to be used only RPD in which air passes through filter(s) before
when escaping (emergency egress) from a being inhaled
dangerous environment
NOTE The device can be unassisted, power
assisted or powered.
3.66
exhalation valve
3.76
non-return valve which allows the release of
fit test
exhaled and excess breathable gas from the RPD
use of a challenge agent and specific protocol to
qualitatively or quantitatively determine an
3.67
individual’s ability to obtain an adequate seal with
explosive atmosphere
a specific make, model, and size of an RPD
mixtures of substances with air, under atmospheric
conditions, in the form of gases, vapours, mists or
3.77
dusts in which, after ignition has occurred,
flow rate
combustion spreads to the entire unburned mixture
air supply
volume (mass) of breathable gas passing through
3.68
the device in a given time
exposed parts
any part of the RPD which may come in contact
3.78
with the ambient atmosphere during foreseeable
fogging
conditions of use
reduction of the field of vision and visual acuity
caused by condensation of humidity inside the
3.69
visor
eye irritation (external)
redness, itching or tearing of the eyes caused by 3.79
gases, vapours, particles and liquids fume
solid aerosols formed when the material from a
3.70 volatilised solid condenses in air
eye irritation (internal)
3.80
redness, itching or tearing of the eyes caused by
gas
the RPD itself
fluid that is in a gaseous state at standard
temperature and pressure that expands to
3.71
occupy the space or enclosure in which it is
fabric component
confined
any single, or combination of, natural or synthetic
material(s) that are pliable and that are made by
3.81
weaving, felting, forming, or knitting
gas filter
filter intended to remove specific gases and
3.72
vapours from the atmosphere passing through it
face seal leakage
leakage between the face and the respiratory
3.82
interface
gas filter capacity
volume or mass of a gaseous contaminant that a
3.73
gas filter can adsorb, absorb or catalyze the
field of vision
breakdown of
area of sight while wearing an RPD
3.83
3.74
gas filter change schedule
filter holder
time interval after which a used gas filter is
component which is attached to either a
replaced with a new one
respiratory interface or other part of the device and
into which a filter, either encapsulated or
3.84
unencapsulated, is inserted
gas filtering RPD
device consisting of a respiratory interface with a
filter which removes certain gases or vapours from
the air to be inhaled by the wearer for a limited
period
© ISO 2010 – All rights reserved 5

---------------------- Page: 9 ----------------------
ISO 16972:2010(E)
3.85 3.94
hazardous atmosphere immediately dangerous to life or health
any atmosphere that is oxygen-deficient, IDLH
exceeds an occupational exposure limit, atmosphere that poses an immediate threat to life,
presents a fire/explosion hazard, and/or contains would cause irreversible adverse health effects, or
an airborne toxic or disease-producing would impair an individual’s ability to escape from
contaminant in concentrations deemed to be a dangerous atmosphere
hazardous
3.95
3.86 impact resistance
hazard ratio ability of RPD to withstand mechanical shock and
estimated/measured airborne concentration of a dynamic stress from environment
substance divided by the occupational exposure
limit
3.96
inhalation valve
NOTE This ratio is calculated for each gas, vapour,
valve which opens during inhalation and closes
and/or particulate component, or for a mixture when the
during exhalation
components have additive effects, that pose a
respiratory hazard.
3.97
inhaled air
3.87
air breathed in by the wearer
head harness
means of holding a respiratory interface in place
3.98
on the head
integral filter
filter which is not separable from the rest of the
3.88
respiratory interface
heads up display
HUD
3.99
visual monitor or warning in the line of sight of the
interactive flow rate
RPD wearer
actual RPD breathing gas flow per time as a result
of the wearer’s demand
3.89
high pressure
3.100
equal to or greater than 1 MPa (10 000 mbar)
intrinsic safety
absolute pressure
various designations that ensure the RPD is not a
source of ignition in explosive atmospheres
3.90
hose
3.101
hollow flexible conduit to carry breathable gas
intrinsically safe (IS) RPD
designated as low, medium or high pressure
respiratory protective device that has been
certified as not providing a source of ignition in an
3.91
explosive atmosphere
hydration facility
design feature of RPD to allow the wearer to drink
3.102
without doffing of RPD
inward leakage
leakage of the ambient atmosphere into the
3.92
respiratory interface from all sources excluding
hydrostatic test
filter(s) where present, when measured in the
calibrated expansion pressure test of the structural
laboratory in the specific test atmosphere
integrity of cylinders
NOTE It is expressed as a ratio of contaminant
3.93
concentration inside an RPD and ambient atmosphere,
hypoxia
as follows:
any condition in which there is an inadequate
Inward leakage (%) = C /C × 100
i o
supply of oxygen in the tissues
where
C is the concentration of challenge agent inside
i
the respiratory interface;
C is the concentration of challenge agent outside
o
inside the respiratory interface.
6 © ISO 2010 – All rights reserved

---------------------- Page: 10 ----------------------
ISO 16972:2010(E)
3.103 3.112
laboratory gas filter capacity marking
mass/volume of a specific test agent that will be information included on the device to indicate
removed or retained by certain mechanisms (e.g. specific RPD characteristics
physisorption, chemisorption, catalytical
conversion, etc.) under specified conditions of 3.113
temperature, relative humidity, challenge test gas
mass median aerodynamic diameter
concentration and the flow rate MMAD
point in an aerodynamic particle size distribution
NOTE The mass/volume is determined by
where half of the mass lies in particles with a
measuring the breakthrough time at a defined
diameter less than the MMAD and half in particles
breakthrough concentration.
with diameters greater than the MMAD
3.104
3.114
leak-tightness
material’s compatibility with skin
ability to withstand a loss of pressure inside an
characteristic of material resulting in insignificant
RPD over a given time as determined by a
irritation to the wearers’ skin when in direct contact
laboratory test
3.115
3.105
maximum flow condition
life cycle
those factors appropriate to the design specified
time between date of manufacturing of the device
by the manufacturer which give rise to the highest
to the date when device has to be withdrawn from
flow rate
service
3.116
3.106
maximum use concentration
liquefied-breathing gas
MUC
oxygen or air stored in liquid form and supplied to
maximum atmospheric concentration of a
the wearer in a gaseous form
hazardous substance from which the RPD wearer
can be expected to be protected when wearing an
3.107
RPD, and is determined by the protection level of
loose fitting respiratory interface
the respiratory protective device or class of
respiratory interface which does not rely on
respiratory protective devices and the
forming a complete seal to the wearer’s skin
occupational exposure limit of the hazardous
substance
3.108
low boiling organic compound
NOTE The maximum use concentration usually
organic compound having a boiling point u 65 °C can be determined mathematically by multiplying the
protection level specified for a respiratory protective
at atmospheric pressure
device by the occupational exposure limit used for the
hazardous substance.
3.109
low pressure
3.117
pressure up to 100 hPa (mbar) above atmospheric
mechanical shock
pressure (gauge)
dynamic force on the device during a fall from a
given height as determined by a laboratory test
3.110
manufacturer’s minimum design condition
3.118
lowest level of operating condition of the device as
mechanical strength of visor
stated by the manufacturer at which the complete
ability of the device to withstand mechanical stress
device will still meet the requirements for the
to the barrier in front of the eyes
designated class
3.119
3.111
medium pressure
manufacturer’s minimum design flow rate
pressure between 100 hPa (mbar) above
MMDF
atmospheric pressure to 1 MPa (10 000 mbar)
minimum air flow rate, as stated by the
pressure gauge
manufacturer, at which the relevant requirements
are met
© ISO 2010 – All rights reserved 7

---------------------- Page: 11 ----------------------
ISO 16972:2010(E)
3.120 3.129
metabolic simulator multi-type combination filter
programmable automatic breathing machine that combination filter which meets the requirements
can simulate the characteristics of both human of more than one type of gas and particle filter
breathing (variable tidal volume and respiratory
rate, humidity, temperature) and metabolic 3.130
functions (variable oxygen consumption and
multi-type gas filter
carbon dioxide production) gas filter which meets the requirements of more
than one type of gas filter
3.121
minimum flow condition 3.131
those factors appropriate to the design specified
negative pressure
by the manufacturer which give rise to the lowest pressure inside the respiratory interface, hose, etc.
flow rate
that is lower than that of the ambient atmosphere
NOTE It is expressed in pascals (Pa).
3.122
minimum required protection factor
MRPF 3.132
level of protection required, derived from the nominal working duration
adequacy assessment procedure working time of a device, used for the classification
determined in laboratory tests with a flow rate
3.123 specified in an International Standard
minute ventilation
total volume of air exchanged in the lungs during 3.133
one minute, V in l/min BTPS occupational exposure limit
E
OEL
3.124 maximum concentration of airborne contaminants
deemed to be acceptable, as defined by the
minute volume
quantity of air exhaled in one minute authority having jurisdiction
3.134
3.125
mist operating pressure
pressure(s) developed within the RPD during
liquid droplets generated by condensation of
vapour back to the liquid state or by breaking up a service
liquid into a dispersed state
3.135
3.126 oxygen compatibility
capability of RPD to allow direct contact with
mode of operation
primary means of supplying the wearer with pressurised oxygen without risk of fire or explosion
by being oil and grease free
breathable gas, i.e., particle filtering, gas and
vapour filtering, or breathable gas supplying
3.136
oxygen consumption
3.127
monitor amount of oxygen consumed by the human tissues
for aerobic energy production, VO in l/min STPD
component of an RPD to enable the wearer to
2
continuously assess that the manufacturer’s
minimum design air flow rate or manufacturer’s 3.137
minimum design conditions are met oxygen deficient
condition based on an oxygen concentration or
partial pressure below which a person may be
3.128
multi-functional RPD adversely affected
RPD which are capable of operating within its
NOTE Each authority having jurisdiction may
mode of operation by using different operating
establish an alternative definition or specific limit.
methods; e.g. power assist filtering devices, power
on/off, compressed breathable gas system with
3.138
compressed breathable gas device
oxygen-enriched air
air containing oxygen at higher concentrations
than that of atmospheric air at sea level
8 © ISO 2010 – All rights reserved

---------------------- Page: 12 ----------------------
ISO 16972:2010(E)
3.139 3.148
particle protection level
generic term used to describe solid or liquid degree of respiratory protection allocated to an
substances in the finely divided state and refers to RPD for the purposes of selection and use that is
particulate aerosols expected to be provided to wearers when used
within an effective RPD progr
...

NORME ISO
INTERNATIONALE 16972
Première édition
2010-03-15



Appareils de protection respiratoire —
Termes, définitions, symboles
graphiques et unités de mesure
Respiratory protective devices — Terms, definitions, graphical symbols
and units of measurement




Numéro de référence
ISO 16972:2010(F)
©
ISO 2010

---------------------- Page: 1 ----------------------
ISO 16972:2010(F)
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info
du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir
l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,
veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.


DOCUMENT PROTÉGÉ PAR COPYRIGHT


©  ISO 2010
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse

ii © ISO 2010 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO 16972:2010(F)
Sommaire Page
Avant-propos .iv
1 Domaine d’application .1
2 Références normatives.1
3 Termes et définitions .1
4 Symboles graphiques utilisés sur un APR.13
4.1 Introduction.13
4.2 Exemples d’utilisation des symboles graphiques .13
4.2.1 Voir notice d’information du fabricant .13
4.2.2 Fin de durée de stockage .14
4.2.3 Plage de températures pour les conditions de stockage.14
4.2.4 Humidité maximale pour les conditions de stockage .14
5 Unités de mesure.14
5.1 Unités.14
Annexe A (informative) Termes et définitions concernant les appareils de protection respiratoire
dans les normes et réglementations nationales en vigueur.15
Annexe B (informative) Abréviations utilisées.40
Bibliographie.41

© ISO 2010 – Tous droits réservés iii

---------------------- Page: 3 ----------------------
ISO 16972:2010(F)
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne
pas avoir identifié de tels droits de propriété et averti de leur existence.
L'ISO 16972 a été élaborée par le comité technique ISO/TC 94, Sécurité individuelle — Vêtements et
équipements de protection, sous-comité SC 15, Appareils de protection respiratoire.
iv © ISO 2010 – Tous droits réservés

---------------------- Page: 4 ----------------------
NORME INTERNATIONALE ISO 16972:2010(F)

Appareils de protection respiratoire — Termes, définitions,
symboles graphiques et unités de mesure
1 Domaine d’application
3 Termes et définitions
La présente Norme internationale s’applique aux
Pour les besoins du présent document, les termes
appareils de protection respiratoire. Elle définit les
et définitions suivants s’appliquent.
termes d’usage courant et spécifie les unités de
NOTE Les termes sont répertoriés par ordre
mesure afin d’uniformiser les interprétations et
alphabétique ANGLAIS. Les termes faisant référence
d’éviter les ambiguïtés. Elle indique les symboles
aux APR actuels ne sont pas répertoriés car ils sont liés
graphiques devant, le cas échéant, être apposés
à leur conception et sont décrits dans l’Annexe A. Un
sur les appareils de protection respiratoire (APR)
terme apparaissant en gras dans une définition signale
ou sur certaines parties de ces appareils ou
un terme défini ailleurs dans la présente liste de
pouvant figurer dans les manuels d'instruction
définitions.
destinés à former la ou les personnes utilisant les
APR au fonctionnement de ces appareils.
3.1
résistance à l’abrasion
aptitude d’un APR et/ou de ses composants à
résister à la dégradation due à des effets abrasifs
2 Références normatives
(par exemple un éraflement, un grattement, un
frottement)
Les documents de référence suivants sont
indispensables pour l'application du présent
3.2
document. Pour les références datées, seule
appareil de protection respiratoire lors d’un
l'édition citée s'applique. Pour les références non
grenaillage
datées, la dernière édition du document de
appareil conçu pour protéger le porteur contre
référence s'applique (y compris les éventuels
l’inhalation, l’impact ou l’abrasion de matières
amendements).
utilisées ou générées lors d’un grenaillage
ISO 7000, Symboles graphiques utilisables sur le
3.3
matériel — Index et tableau synoptique
accessoire
élément(s) fixé(s) à l’APR qui n'est(ne sont) pas
1)
CEI 80416-1 , Principes de base pour les
nécessaire(s) pour que l’APR satisfasse aux
symboles graphiques utilisables sur le matériel —
exigences de performance de la norme ISO
Partie 1: Création des symboles graphiques pour
relative aux APR et qui ne compromet(tent) pas le
enregistrement
niveau de protection pour lequel il est conçu
2)
ISO 80416-2 , Principes de base pour les
3.4
symboles graphiques utilisables sur le matériel —
évaluation de l’adéquation
Partie 2: Forme et utilisation des flèches
méthode sélective permettant de déterminer l’APR
le plus adapté à limiter, à des niveaux
acceptables, l’exposition du porteur à un danger
3.5
diamètre aérodynamique
                              diamètre d’une particule sphérique de masse
volumique égale à un, ayant la même vitesse de
1) Annule et remplace l'ISO 3461-1:1988.
sédimentation que la particule considérée
2) Annule et remplace l'ISO 4196:1984.
© ISO 2010 – Tous droits réservés 1

---------------------- Page: 5 ----------------------
ISO 16972:2010(F)
3.6
ambiant et à laquelle les ouvriers peuvent se
aérosol
trouver exposés dans leur environnement de
suspension de particules solides, liquides ou de
travail
particules solides et liquides dans un milieu
gazeux 3.16
point de rosée atmosphérique
3.7 température à laquelle l’humidité contenue dans
pénétration de l’aérosol un gaz commence à se condenser lorsque le gaz
capacité des particules à traverser un matériau est refroidi à la pression atmosphérique normale
filtrant les particules (1 013,25 hPa)
3.8
3.17
résistance au débit d’air
contrôle biologique
pression différentielle entre l’amont et l’aval d’un
analyse de l’air expiré d’un liquide biologique (par
courant, causée par l’écoulement de l’air au
exemple l’urine, le sang, la transpiration) ou d’un
travers de parties ou de composants de l’APR, tels
tissu cellulaire (par exemple cheveux, ongles), afin
qu’une soupape d’expiration, une soupape
d’évaluer le degré auquel une personne a été
d’inspiration, un(des) filtre(s), un tube
exposée à un polluant/à un danger
3.9 3.18
appareil de protection respiratoire filtrant harnais de sécurité
appareil dans lequel l’air ambiant passe au travers moyen permettant à un porteur de porter certains
d’un ou de plusieurs éléments filtrants qui composants d’un APR sur le corps
éliminent le(s) polluant(s). L’air passe au travers
de l’élément filtrant par la respiration ou à l’aide 3.19
d’un dispositif soufflant concentration de claquage
concentration d’un gaz d’essai, dans l’air en aval
3.10
d'un filtre à gaz soumis à un essai de capacité à
dérivation de l’air ambiant
partir de laquelle ce filtre est considéré comme
moyen permettant au porteur de respirer
saturé
l’atmosphère ambiante avant d’entrer ou après
avoir quitté une atmosphère dangereuse 3.20
courbe de claquage
3.11 graphique représentant la concentration de la
système d’air ambiant substance d’essai en aval du(des) filtre(s) à gaz
appareil utilisé pour alimenter directement en air en fonction du temps
ambiant à basse pression un APR fournissant de
l’atmosphère (fonctionnement manuel ou assisté) 3.21
temps de claquage
3.12
durée comprise entre le début d’un essai de
atmosphère ambiante
capacité d’un filtre à gaz et le moment où la
air environnant le porteur de l’APR
concentration de claquage a été atteinte, dans
l’air en aval du filtre à gaz, dans les conditions
3.13
définies
concentration ambiante
concentration d’un composé dans l’air environnant 3.22
le porteur de l’APR courbe du temps de claquage
graphique représentant la relation entre la
3.14
concentration d’essai et le temps de claquage
conditions ambiantes de laboratoire
du(des) filtre(s) à gaz
atmosphère dans laquelle la température est
comprise entre 16 °C et 32 °C et l’humidité relative
3.23
entre 20 % et 80 %
gaz respirable
mélanges de gaz adaptés à la respiration sans
3.15
effet nocif sur la santé
contaminant atmosphérique
substance potentiellement nocive présente en
concentration élevée inadmissible dans l’air
2 © ISO 2010 – Tous droits réservés

---------------------- Page: 6 ----------------------
ISO 16972:2010(F)
EXEMPLE Température du corps (37 °C),
3.24
pression atmosphérique (1 013,25 hPa) et air saturé
bouteille de gaz respirable
(pression de la vapeur = 62,66 hPa).
partie intégrante de l’APR contenant le gaz
respirable
3.33
respiration partagée
3.25
pratique permettant à une deuxième personne de
qualité du gaz respirable
partager simultanément la même source de gaz
composition d’un gaz respirable tel que défini
respirable que celle du porteur de l’APR alors que
dans les normes applicables
les deux personnes tentent de rejoindre un lieu
sécurisé
3.26
cycle respiratoire
3.34
pédiode composée d’une inspiration et d’une
soupape de dérivation
expiration
composant d’un APR, servant de soupape
manuelle d’urgence et permettant l’alimentation en
3.27
gaz respirable nécessaire lorsque la voie
sac respiratoire
d’alimentation normale ne fonctionne plus
composant d’un APR qui compense les variations
de l’alimentation en gaz respirable et satisfait aux
3.35
besoins de débit de pointe à l’inspiration
limites de concentration de CO
2
concentration maximale autorisée en dioxyde de
3.28
carbone présent dans le gaz respirable inhalé
régénération du gaz respiratoire
procédé par lequel un APR absorbe le dioxyde de
3.36
carbone dans le gaz expiré et fournit l’oxygène,
tronçon carbonisé
contrôle la vapeur d’eau et la température du gaz
tronçon fragilisé d’un matériau ou d’un tissu qui a
à respirer
été exposé à une énergie thermique
3.29
3.37
simulateur respiratoire
dispositif de vérification
appareil de ventilation qui simule la ventilation
caractéristique de l’APR qui permet au porteur de
respiratoire en utilisant des formes d’ondes, qui
vérifier avant utilisation ou régulièrement pendant
sont sinusoïdales ou représentent le cycle
l’utilisation, que les conditions minimales de
d’inspiration et d’expiration
conception du fabricant sont satisfaites
NOTE Voir également simulateur métabolique.
3.38
3.30 résistance au nettoyage/à la désinfection
résistance respiratoire de pointe capacité de l’appareil à résister aux méthodes de
pression différentielle maximale d’un APR pendant nettoyage et de désinfection définies par le
fabricant
l’inspiration (résistance de pointe à l’inspiration) ou
l’expiration (résistance de pointe à l’expiration)
3.39
3.31 colmatage
résistance respiratoire
accumulation de particules sur un filtre provoquant
pression différentielle entre l’amont et l’aval d’un une augmentation importante de sa résistance à
courant, causée par un APR sur le débit de gaz
l’écoulement
respirable pendant l’inspiration (résistance à
3.40
l’inspiration) ou l’expiration (résistance à
filtre combiné
l’expiration)
filtre conçu pour éliminer les particules solides
3.32 et/ou liquides ainsi que les vapeurs et les gaz
température du corps à pression saturée dispersés de l’air le traversant
BTPS
condition normale pour l’expression des 3.41
paramètres de ventilation APR combiné
APR qui peut fonctionner en mode filtrant ou en
mode isolant
© ISO 2010 – Tous droits réservés 3

---------------------- Page: 7 ----------------------
ISO 16972:2010(F)
3.42 3.51
performance de communication point de rosée
aptitude du porteur à communiquer face à face température de l’air à une pression spécifiée à
avec autrui à une distance donnée laquelle la condensation d’eau se produit
3.43 3.52
compatibilité retrait de l’équipement
capacité d’un APR à être utilisé conjointement processus de retrait effectif de l’APR
avec d’autres équipements de protection
3.53
individuelle (EPI)
mise en place l’équipement
3.44 processus de mise en place effective de l’APR
personne compétente
personne possédant une expérience appropriée et 3.54
suffisante, et des connaissances pratiques et égoutter
théoriques des éléments d’un programme s’écouler en formant des gouttelettes ou des
respiratoire dont elle est responsable gouttes
3.55
3.45
tête artificielle
espace confiné
modèle imitant une tête humaine utilisé lors des
zone à accès réduit, comme défini dans les
essais sur l’APR
réglementations nationales, qui nécessite des
précautions particulières pour pouvoir y accéder
3.56
3.46 durabilité
robinet de débit continu capacité de l’appareil à résister à l'ensemble des
robinet de réglage du débit en gaz respirable contraintes liées à son utilisation sans nuire à ses
alimentant le porteur d’un APR équipé d’une performances ni à son intégrité
source de gaz respirable permettant à celui-ci de
3.57
régler son écoulement continu dans les limites
poussière
définies
aérosol constitué de particules solides produites
mécaniquement à partir de particules plus grandes
3.47
de submicroscopique à macroscopique
diamètre médian en nombre
CMD
NOTE Voir aussi vapeur et fumée.
taille de particule d’une distribution
granulométrique pour laquelle une moitié du
3.58
nombre total de particules a des dimensions
dispositif de respiration d’urgence
supérieures et l'autre moitié, des dimensions qui
mécanisme de l’APR se mettant en marche
inférieures
lorsque le mode de fonctionnement normal de
l’appareil est défaillant
3.48
espace mort
NOTE Il fournit un niveau de protection approprié
zone dans laquelle le gaz expiré n’a pas été purgé
pendant une certaine période afin de permettre au
et est susceptible d’être respiré à nouveau
porteur de l’appareil de quitter la zone de travail, sans
assistance, et de rejoindre un lieu sécurisé
3.49
parties démontables
3.59
parties de l’appareil conçues pour être
compatibilité électromagnétique
déconnectées et reconnectées à la main, sans
CEM
l’utilisation d’outils
capacité d’un appareil, d’une unité d’équipement
ou d’un système à fonctionner correctement dans
3.50
son environnement électromagnétique sans
durée de conception
occasionner, lui même, de perturbations
durée spécifiée par le fabricant pendant laquelle
électromagnétiques intolérables dans cet
les conditions de conception d’un appareil sont
environnement
satisfaites, par exemple le débit
4 © ISO 2010 – Tous droits réservés

---------------------- Page: 8 ----------------------
ISO 16972:2010(F)
3.60 3.69
fin de la durée d'utilisation de la batterie irritation oculaire
niveau le plus faible de la capacité d’une batterie
〈externe〉 rougeur, démangeaison ou larmoiement
auquel l’APR continue de pouvoir fonctionner des yeux causé par des gaz, vapeurs, particules
correctement
et liquides
3.61 3.70
indicateur de la fin du cycle de vie irritation oculaire
système qui indique la fin du cycle de vie complet 〈externe〉 rougeur, démangeaison ou larmoiement
d’un APR des yeux causé par l’APR même
3.62
3.71
indicateur de fin de durée d’utilisation
composant en tissu
ESLI
matériau synthétique ou naturel, ou combinaison
système avertissant le porteur d'un APR filtrant à
de matériaux souples produits par tissage,
gaz que la fin de la protection respiratoire qu’il
feutrage, fibrage ou tricotage
assure est imminente
3.72
3.63 fuite faciale
environnement fuite entre le visage et l’interface respiratoire
zone à risques potentiels dans laquelle l’APR doit
être utilisé
3.73
champ de vision
3.64
zone de vision lors du port d’un APR
facteurs/paramètres ergonomiques
tous les aspects de l’APR qui sont prévus pour
3.74
maximiser la capacité des porteurs à effectuer
support du filtre
leurs tâches tout en limitant au strict minimum la
composant fixé à une interface respiratoire ou à
fatigue et l’inconfort du porteur
une autre partie de l’appareil et dans lequel est
inséré un filtre emboîté ou non
3.65
APR d’évacuation
3.75
appareil de protection respiratoire utilisé
appareil filtrant
uniquement en cas d’évacuation (sortie de
APR dans lequel l’air passe à travers un ou
secours) d'un environnement dangereux
plusieurs filtres avant d’être inhalé
3.66 NOTE L’appareil peut être non assisté, à ventilation
assistée ou à assistance motorisée.
soupape d’expiration
soupape anti-retour permettant l’évacuation du
3.76
gaz expiré et l'excès de gaz respirable de l’APR
essai d’ajustement
utilisation d’un agent test et d’un protocole
3.67
spécifique pour déterminer qualitativement et
atmosphère explosive
quantitativement l'aptitude d’une personne à
mélange de substances avec l’air, dans les
obtenir une étanchéité appropriée avec une
conditions atmosphériques, sous forme de gaz,
marque, un modèle et une taille spécifiques d’APR
vapeurs, brouillards ou poussières, dans lequel,
après inflammation, la combustion se propage à
3.77
l’ensemble du mélange non brûlé
débit
approvisionnement d’air
3.68
volume (masse) de gaz respirable traversant
parties exposées
l’appareil dans un temps donné
toute partie de l’APR pouvant entrer en contact
avec l’atmosphère ambiante dans les conditions
3.78
d’utilisation prévues
embuage
réduction du champ de vision et de l’acuité visuelle
causée par la condensation d’humidité à l’intérieur
de l’oculaire
© ISO 2010 – Tous droits réservés 5

---------------------- Page: 9 ----------------------
ISO 16972:2010(F)
3.79 3.87
fumée serre-tête
aérosols solides formés lorsque la matière d’un dispositif permettant de maintenir en place une
solide volatilisé se condense dans l’air interface respiratoire sur la tête
3.80 3.88
gaz visualisation tête haute
fluide à l’état gazeux à une pression et une VTH
température normales qui se dilate pour occuper moniteur ou signal d'alarme visuel dans le champ
l’enceinte ou l’espace dans lequel il est enfermé de vision du porteur de l’APR
3.81 3.89
filtre anti-gaz haute pression
filtre conçu pour éliminer les gaz et vapeurs pression égale ou supérieure à la pression
spécifiques de l’atmosphère le traversant absolue de 1 MPa (10 000 mbar)
3.82
3.90
capacité du filtre anti-gaz
tuyau
volume ou masse d’un polluant gazeux qu’un filtre
conduit flexible creux transportant le gaz
à gaz peut adsorber, absorber ou dégrader par
respirable désigné comme basse, moyenne ou
catalyse
haute pression
3.83 3.91
calendrier de remplacement d'un filtre anti-gaz dispositif d’hydratation
laps de temps au terme duquel un filtre à gaz caractéristique de conception d’un APR
usagé est remplacé par un filtre neuf permettant au porteur de boire sans retrait de
l’équipement
3.84
APR filtrant anti-gaz
3.92
appareil constitué d’une interface respiratoire
essai hydrostatique
munie d’un filtre qui élimine certains gaz ou
essai normalisé de résistance à la pression des
vapeurs de l’air inhalé par le porteur pendant une
bouteilles
période limitée
3.93
3.85 hypoxie
atmosphère dangereuse situation dans laquelle la quantité d’oxygène
atmosphère qui est appauvrie en oxygène, alimentant les tissus est insuffisante
dépasse une limite d’exposition
professionnelle, présente un risque 3.94
d’incendie/d’explosion et/ou contient un agent présentant un danger immédiat pour la vie ou
contaminant toxique ou pathogène en suspension la santé
dans l’air dans des concentrations jugées IDLH
dangereuses atmosphère qui présente une menace immédiate
pour la vie, aurait des effets nocifs pour la santé
3.86
ou diminuerait la capacité d’une personne à fuir
taux de risque
une atmosphère dangereuse
concentration estimée/mesurée d’une substance
en suspension dans l’air divisée par la limite 3.95
d’exposition professionnelle résistance à l'impact
capacité de l’APR à résister aux impacts
NOTE Ce rapport est calculé pour chaque mécaniques et aux contraintes dynamiques
composant de gaz, vapeur et/ou particule ou pour un
d’environnement
mélange lorsque les composants ont des effets
cumulatifs présentant un risque respiratoire.
3.96
soupape d’inspiration
soupape qui s’ouvre à l’inspiration et se ferme à
l’expiration
6 © ISO 2010 – Tous droits réservés

---------------------- Page: 10 ----------------------
ISO 16972:2010(F)
NOTE La masse/le volume est déterminé en
3.97
mesurant le temps de claquage à une concentration de
air inhalé
claquage définie.
air inspiré par le porteur
3.104
3.98
étanchéité
filtre intégré
capacité à résister à une perte de pression à
filtre qui n’est pas séparable du reste de
l’intérieur d’un APR sur une période donnée
l’interface respiratoire
comme déterminé par un essai de laboratoire
3.99
3.105
débit interactif
cycle de vie
débit de gaz réel de l’APR résultant de la
période comprise entre la date de fabrication de
respiration du porteur
l’appareil et la date à laquelle l’appareil doit être
mis hors service
3.100
sécurité intrinsèque
3.106
dispositions garantissant que l’APR ne constitue
gaz respiratoire liquéfié
pas une source d’inflammation dans des
oxygène ou air conservé sous forme liquide et
atmosphères explosives
fourni au porteur sous forme gazeuse
3.101
3.107
APR intrinsèquement sécurisé (IS)
interface respiratoire à ajustement lâche
appareil de protection respiratoire certifié
interface respiratoire qui ne vise pas à former une
comme n’étant pas une source d’inflammation
jonction parfaitement étanche avec la peau du
dans une atmosphère explosive
porteur
3.102
3.108
fuite vers l’intérieur
composé organique à bas point d'ébullition
fuite de l’atmosphère ambiante dans l’interface
composé organique ayant un point d’ébullition
respiratoire à partir de toutes les sources à
u 65 °C à la pression atmosphérique
l’exclusion des filtres de l’appareil, lorsqu’elle est
mesurée en laboratoire dans l’atmosphère d’essai
3.109
spécifique
basse pression
pression jusqu’à 100 hPa (mbar) au-dessus de la
NOTE Elle est exprimée sous la forme d’un rapport
pression atmosphérique (au manomètre)
entre la concentration du polluant à l’intérieur d’un APR
et l’atmosphère ambiante, comme suit:
3.110
conditions minimales de conception prévues
Fuite vers l’intérieur (%) = C /C × 100
i o
par le fabricant
niveau le plus bas des conditions de

fonctionnement de l’appareil, tel que déclaré par le
fabricant, dans lesquelles il continue de satisfaire
C est la concentration d’agent d'essai à l’intérieur
i
aux exigences de la classe désignée
de l’interface respiratoire;
3.111
C est la concentration d’agent d'essai à l’extérieur
o
débit minimal prévu par le fabricant
de l’interface respiratoire.
MMDF
débit minimal, indiqué par le fabricant, auquel les
3.103
exigences pertinentes sont satisfaites
capacité d’un filtre anti-gaz en laboratoire
masse/volume d’un agent d’essai spécifique qui
3.112
sera éliminé ou retenu par certains mécanismes
marquage
(par exemple physisorption, chimisorption, réaction
informations apposées sur l’appareil et indiquant
catalytique) sous certaines conditions de
les caractéristiques spécifiques de l’APR
température, d’humidité relative, de concentration
en gaz d’essai, ainsi que de débit
© ISO 2010 – Tous droits réservés 7

---------------------- Page: 11 ----------------------
ISO 16972:2010(F)
3.113 3.120
diamètre aérodynamique médian en masse simulateur métabolique
simulateur respiratoire automatique
DAMM
programmable pouvant simuler les
point dans une répartition granulométrique
caractéristiques de la respiration humaine (volume
aérodynamique où la moitié de la masse est
courant et fréquence respiratoire variables,
constituée de particules avec un diamètre inférieur
humidité, température) et des fonctions
au DAMM et l’autre moitié, de particules avec un
métaboliques (consommation d’oxygène et
diamètre supérieur au DAMM
production de dioxyde de carbone variables)
3.114
3.121
compatibilité du matériau avec la peau
condition de débit minimal
caractéristique du matériau pouvant se traduire
facteurs propres à la conception spécifiée par le
par une légère irritation de la peau du porteur
fabricant qui donnent lieu au débit le moins élevé
lorsqu’il se trouve en contact direct avec elle
3.122
3.115
facteur de protection minimale requis
condition de débit maximal
MRPF
facteurs propres à la conception spécifiée par le
niveau de protection requis, indiqué par la
fabricant qui donnent lieu au débit le plus élevé
procédure d’évaluation de l’adéquation
3.116
3.123
concentration maximale d'utilisation
ventilation par minute
CMU
volume d’air, V , échangé à l’intérieur des
E
concentration atmosphérique maximale d’une
poumons en une minute, en l/min BTPS
substance dangereuse à partir de laquelle le
porteur d’APR peut être considéré comme protégé
3.124
lorsqu’il porte un APR, elle est déterminée par le
volume par minute
niveau de protection attribué de l’appareil de
quantité d’air expiré en une minute
protection respiratoire ou par la classe de
l’appareil de protection respiratoire ainsi que la
3.125
limite d’exposition professionnelle à la
brouillard
substance dangereuse
suspension de gouttelettes liquides générées par
la condensation de vapeur retournant à l’état
NOTE La CMU peut généralement être déterminée
liquide ou par dispersion d’un liquide par giclage
mathématiquement en multipliant le niveau de protection
ou pulvérisation
attribué spécifié pour un appareil de protection
respiratoire par la limite d’exposition professionnelle
3.126
utilisée pour la substance dangereuse.
mode de fonctionnement
moyen princip
...

Questions, Comments and Discussion