Corrigendum 1 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for testing and measuring circuits

Specifies a method for the determination of the amount of halogen acid gas, other than hydrofluoric acid, evolved during the combustion of compounds based on halogenated polymers and compounds containing halogenated additives taken from cable constructions. This method is not recommended for use where the amount of halogen acid evolved is less than 5 mg/g of the sample taken.[
]Has the status of a group safety publication in accordance with IEC Guide 104.

Corrigendum 1 - Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 2-030: Exigences particulières pour les circuits de test et de mesure

Prescrit une méthode pour la détermination de la quantité de gaz acide halogéné, autre que l'acide fluorhydrique, émis durant la combustion de mélanges à base de polymère halogénés et de mélanges contenant des additifs halogénés prélevés sur un câble.[
]L'utilisation de cete méthode n'est pas recommandée lorsque la quantité d'acide halogéné émis est inférieure à 5 mg/g d'échantillon prélevé.[
]A le statut d'une publication fondamentale de sécurité conformément au Guide 104.

General Information

Status
Published
Publication Date
10-May-2011
Current Stage
DELPUB - Deleted Publication
Start Date
12-Jan-2017
Completion Date
14-Feb-2026

Relations

Effective Date
05-Sep-2023
Effective Date
05-Sep-2023

Buy Documents

Standard

IEC 61010-2-030:2010/COR1:2011 - Corrigendum 1 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for testing and measuring circuits Released:5/11/2011

English and French language (10 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

ECOCERT

Organic and sustainability certification.

COFRAC France Verified

Intertek Testing Services NA Inc.

Intertek certification services in North America.

ANAB United States Verified

NSF International

Global independent organization facilitating standards development and certification.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

IEC 61010-2-030:2010/COR1:2011 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Corrigendum 1 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for testing and measuring circuits". This standard covers: Specifies a method for the determination of the amount of halogen acid gas, other than hydrofluoric acid, evolved during the combustion of compounds based on halogenated polymers and compounds containing halogenated additives taken from cable constructions. This method is not recommended for use where the amount of halogen acid evolved is less than 5 mg/g of the sample taken.[<BR>]Has the status of a group safety publication in accordance with IEC Guide 104.

Specifies a method for the determination of the amount of halogen acid gas, other than hydrofluoric acid, evolved during the combustion of compounds based on halogenated polymers and compounds containing halogenated additives taken from cable constructions. This method is not recommended for use where the amount of halogen acid evolved is less than 5 mg/g of the sample taken.[<BR>]Has the status of a group safety publication in accordance with IEC Guide 104.

IEC 61010-2-030:2010/COR1:2011 is classified under the following ICS (International Classification for Standards) categories: 13.220.40 - Ignitability and burning behaviour of materials and products; 19.080 - Electrical and electronic testing; 29.020 - Electrical engineering in general; 29.060.20 - Cables; 71.040.10 - Chemical laboratories. Laboratory equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

IEC 61010-2-030:2010/COR1:2011 has the following relationships with other standards: It is inter standard links to IEC 61010-2-030:2010, IEC 61010-2-030:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

IEC 61010-2-030:2010/COR1:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


IEC 61010-2-030 CEI 61010-2-030
(1rst edition – 2010) (1ère édition – 2010)

SAFETY REQUIREMENTS FOR ELECTRICAL RÈGLES DE SÉCURITÉ POUR APPAREILS
EQUIPMENT FOR MEASUREMENT, CONTROL, ÉLECTRIQUES DE MESURAGE, DE RÉGULATION
AND LABORATORY USE – ET DE LABORATOIRE –

Part 2-030: Particular requirements for testing Partie 2-030: Exigences particulières
and measuring circuits pour les circuits de test et de mesure

CO RRI G E NDUM 1
101.3.3 Protection by uncertified 101.3.3 Protection par des limiteurs
current limitation devices or de courant non certifiés ou
by impedances des impédances
Replace the first paragraph of item a) as Remplacer le premier paragraphe du point
follows: a) par le suivant:
a) An appropriate single component a) Un composant individuel approprié qui
which is constructed, selected, and doit être fabriqué, choisi et essayé
tested so that safety and reliability for pour assurer la sécurité et la fiabilité
protection against relevant HAZARDS is pour la protection contre les DANGERS
assured. In particular, the component appropriés. Ce composant doit
shall: notamment avoir:
Replace item b) 3) as follows: Remplacer le point b) 3) par le suivant:
3) meet the applicable CLEARANCE 3) avoir la DISTANCE D’ISOLEMENT entre
requirements of Annex K for REINFORCED les extrémités de la combinaison
INSULATION between the terminations of de composants qui respecte les
the combination of components. exigences de l’Annexe K pour
l’ISOLATION RENFORCÉE.
Annexe K
Annex K
(normative)
(normative)
Exigences d’isolation non
Insula
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...