EN 50117-1:2019
(Main)Coaxial cables - Part 1: Generic specification
Coaxial cables - Part 1: Generic specification
This document covers coaxial cables for use in analogue and digital systems. This document should be used in conjunction with EN 50290-1-1. Coaxial cables covered by this document operate in transverse electromagnetic mode (TEM) and are suitable for use in a wide range of digital and analogue applications including CATV, radio frequency systems, instrumentation, broadcasting, telecommunications and data network systems. Various constructions and materials provide for indoor and outdoor applications, including underground and overhead installations, and other environmental protection characteristics. Generally, cables are designed for use in 50 Ohm and 75 Ohm characteristic impedance systems, although other types (e.g. 93/95 Ohm) are also covered. Coaxial cables defined by this document may be incorporated into hybrid cable constructions with optical fibre or multi-element cable components. All cables covered by this document may be subjected to voltages greater than 50 V AC or 75 V DC according to the relevant sectional or detail specification. However, these cables are not intended for direct connection to the mains electricity supply or other low impedance sources.
Koaxialkabel - Teil 1: Fachgrundspezifikation
Câbles coaxiaux - Partie 1: Spécification générique
Le présent document européen s’applique aux câbles coaxiaux destinés à être utilisés dans des réseaux analogiques et numériques. Il convient d’utiliser le présent document conjointement avec l’EN 50290-1-1. Les câbles coaxiaux couverts par le présent document fonctionnent en mode transversal électromagnétique (TEM) et sont adaptés à un large éventail d’applications numériques et analogiques y compris la CATV, les systèmes RF, l’instrumentation, la radiodiffusion et les réseaux de données et de télécommunications. Les différentes constructions et les différents matériaux qui existent permettent des applications intérieures et extérieures, y compris des installations en souterrain et en aérien et d’autres caractéristiques de protection environnementales. Généralement, les câbles sont conçus pour être utilisés dans des réseaux ayant une impédance caractéristique de 50 Ohm et 75 Ohm, bien que d’autres types (par ex. 93/95 Ohm) soient également couverts. Les câbles coaxiaux définis par le présent document peuvent être incorporés à des constructions de câbles hybrides avec des composants de câbles à fibres optiques ou à éléments multiples. Tous les câbles couverts par le présent document peuvent être soumis à des tensions supérieures à 50 V en courant alternatif ou 75 V en courant continu conformément à la spécification intermédiaire ou particulière applicable. Cependant, ces câbles ne sont pas destinés à être directement raccordés au réseau électrique d’alimentation ou à d’autres sources de faible impédance.
Koaksialni kabli - 1. del: Splošna specifikacija
Ta evropski standard zajema koaksialne kable za uporabo v analognih in digitalnih sistemih. Ta standard naj bi se uporabljal v povezavi s standardom EN 50290-1-1.
Koaksialni kabli, vključeni v ta standard, delujejo v prečnem elektromagnetnem polju (TEM) ter so primerni za številne različne digitalne in analogne načine uporabe, vključno s sistemi CATV, radiofrekvenčnimi sistemi, instrumenti, oddajnimi sistemi, telekomunikacijskimi sistemi ter sistemi podatkovnih omrežij. Različne konstrukcije in materiali omogočajo notranjo in zunanjo uporabo, vključno s podzemnimi in nadzemnimi napravami, ter druge karakteristike varovanja okolja.
Na splošno so kabli zasnovani za uporabo v značilnih impedančnih sistemih 50 ohmov in 75 ohmov, čeprav so zajeti tudi drugi tipi (npr. 93/95 ohmov).
Koaksialni kabli, opredeljeni s tem standardom, se lahko vgradijo v konstrukcije hibridnih kablov z optičnimi vlakni ali večelementnimi kabelskimi komponentami.
Vsi kabli, ki jih zajema ta standard, so lahko izpostavljeni napetostim, večjim od 50 V izmenične napetosti ali 75 V enosmerne napetosti, v skladu z ustreznimi področnimi ali podrobnimi specifikacijami. Vendar ti kabli niso namenjeni za neposredno priključitev na električno omrežje ali druge vire z nizko impedanco.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-junij-2019
Nadomešča:
SIST EN 50117-1:2004
SIST EN 50117-1:2004/A1:2007
SIST EN 50117-1:2004/A2:2013
Koaksialni kabli - 1. del: Splošna specifikacija
Coaxial cables - Part 1: Generic specification
Koaxialkabel - Teil 1: Fachgrundspezifikation
Câbles coaxiaux - Partie 1: Spécification générique
Ta slovenski standard je istoveten z: EN 50117-1:2019
ICS:
33.120.10 Koaksialni kabli. Valovodi Coaxial cables. Waveguides
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 50117-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2019
ICS 33.120.10 Supersedes EN 50117-1:2002
English Version
Coaxial cables - Part 1: Generic specification
Câbles coaxiaux - Partie 1: Spécification générique Koaxialkabel - Teil 1: Fachgrundspezifikation
This European Standard was approved by CENELEC on 2019-02-28. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any
alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 50117-1:2019 E
Contents Page
European foreword . 3
1 Scope . 5
2 Normative references . 5
3 Terms and definitions . 7
4 Requirements for cable construction and design . 7
4.1 General . 7
4.2 Inner conductor . 8
4.2.1 Conductor material . 8
4.2.2 Conductor construction . 8
4.3 Dielectric . 9
4.4 Outer conductor or screen . 9
4.5 Filling compounds . 9
4.6 Moisture barriers . 10
4.7 Wrapping layers . 10
4.8 Sheath . 10
4.9 Cable protection . 10
4.10 Cable integral suspension strand (messenger wire) . 10
4.11 Oversheath . 10
4.12 Fauna proofing . 10
4.13 Chemical and/or environmental proofing . 10
4.14 Cable identification . 11
4.14.1 General . 11
4.14.2 Sheath marking . 11
4.15 Labelling . 11
5 Test methods for completed cables . 11
5.1 Electrical test methods. 11
5.1.1 General . 11
5.1.2 Low frequency and DC electrical test methods . 12
5.1.3 High-frequency electrical and transmission test methods. 12
5.2 Mechanical test methods . 12
5.3 Environmental test methods . 13
5.4 Fire performance test methods . 13
Bibliography . 14
European foreword
This document (EN 50117-1:2019) has been prepared by SC 46XA, "Coaxial cables", of CLC/TC 46X,
"Communication cables".
The following dates are fixed:
• latest date by which this document has (dop) 2020-02-28
to be implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2022-02-28
standards conflicting with this document
have to be withdrawn
This document supersedes EN 50117-1:2002.
— In the European foreword, reference to LVD, REACH and ROHS directives was added;
— in Clause 2, "60811-1-1" was replaced by "60811-201/202/203" and "EN 50356, Method for spark
testing of cables" was replaced by "EN 62230, Electric cables - Spark-test method";
— in 4.1, “i.e. the temperature rise due to the current is below the continuous maximum permitted
temperature of the dielectric and the sheath material” was added;
— in 4.2.1: a) b) c) text was added;
— in 4.3, foam dielectric was added, EN 50290-2 series (EN 50290-2-20:2016, Table A.1) was
corrected;
— in 4.4, silvered wires were added,
— f) as in item a) above, applied over the film; was deleted;
— h) “Any combination of the above designs” was added;
— in 4.5, “Longitudinal water tightness may be achieved also by other solutions like swelling powder,
yarns, tapes” was added;
— in 4.8, “EN 50290-2 series (EN 50290-2-20:2016, Table A.1)” was corrected;
— In 4.9, "Metallic protection" was changed into: "Cable protection" and “glass yarns or aramid” was
added;
— In 4.13, “metallic sheath of lead or suitable lead alloy” was deleted, and “Other materials, e.g. FEP or
specific PUR may also be suitable” was added;
— In Table 1:
5.1.1.7 Voltage proof EN 50289-1-3
was deleted;
— In Table 2:
5.1.3.5 Regularity of impedance IEC 61196-1-115
5.1.3.6 Transfer impedance IEC 62153-4-3 Ed2.0
5.1.3.7 Screening attenuation IEC 62153-4-4 Ed2.0
5.1.3.8 Power rating (calculation) IEC 60096-0-1
was added;
— In Table 4:
5.3.9 Tin and silver coating finish IEC 61196-1-303
was added;
— a Bibliography was added.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association.
All materials used for cables according to this standard will fulfil the requirements of the current REACH
Regulation and ROHS Directive.
1 Scope
This document covers coaxial cables for use in analogue and digital systems. This document should be
used in conjunction with EN 50290-1-1.
Coaxial cables covered by this document operate in transverse electromagnetic mode (TEM) and are
suitable for use in a wide range of digital and analogue applications including CATV, radio frequency
systems, instrumentation, broadcasting, telecommunications and data network systems. Various
constructions and materials provide for indoor and outdoor applications, including underground and
overhead installations, and other environmental protection characteristics.
Generally, cables are designed for use in 50 Ohm and 75 Ohm characteristic impedance systems,
although other types (e.g. 93/95 Ohm) are also covered.
Coaxial cables defined by this document may be incorporated into hybrid cable constructions with optical
fibre or multi-element cable components.
All cables covered by this document may be subjected to voltages greater than 50 V AC or 75 V DC
according to the relevant sectional or detail specification. However, these cables are not intended for
direct connection to the mains electricity supply or other low impedance sources.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 50289-1-2, Communication cables - Specifications for test methods - Part 1-2: Electrical test methods
- DC resistance
EN 50289-1-3, Communication cables - Specifications for test methods - Part 1-3: Electrical test methods
- Dielectric strength
EN 50289-1-4, Communication cables - Specifications for test methods - Part 1-4: Electrical test methods
- Insulation resistance
EN 50289-1-5, Communication cables - Specifications for test methods - Part 1-5: Electrical test methods
- Capacitance
EN 50289-1-7, Communication cables - Specifications for test methods - Part 1-7: Electrical test methods
- Velocity of propagation
EN 50289-1-8, Communication cables - Specifications for test methods - Part 1-8: Electrical test methods
- Attenuation
EN 50289-1-11, Communication cables - Specifications for test methods - Part 1-11: Electrical test
methods – Characteristic impedance, input impedance, return loss
EN 50289-3-2, Communication cables - Specifications for test methods - Part 3-2: Mechanical test
methods - Tensile strength and elongation for conductor
EN 50289-3-5, Communication cables - Specifications for test methods - Part 3-5: Mechanical test
methods - Crush resistance of the cable
EN 50289-3-6, Communication cables - Specifications for test methods - Part 3-6: Mechanical test
methods - Impact resistance of the cable
EN 50289-3-7, Communication cables - Specifications for test methods - Part 3-7: Mechanical test
methods - Abrasion resistance of the cable sheath
EN 50289-3-8, Communication cables - Specifications for test methods - Part 3-8: Mechanical test
methods - Abrasion resistance of cable sheath markings
EN 50289-3-9, Communication cables - Specifications for test methods - Part 3-9: Mechanical test
methods - Bending tests
EN 50289-3-16, Communication cables - Specifications for test methods - Part 3-16: Mechanical test
methods - Cable tensile performance
EN 50289-3-17, Communication cables - Specifications for test methods - Part 3-17: Mechanical test
methods - Adhesion of dielectric and sheath
EN 50289-4-2, Communication cables - Specifications for test methods - Part 4-2: Environmental test
methods - Water penetration
EN 50289-4-4, Communication cables - Specifications for test methods - Part 4-4: Environmental test
methods - Resistance to solvents and contaminating fluids
EN 50289-4-6, Communication cables - Specifications for test methods - Part 4-6: Environmental test
methods - Temperature cycling
EN 50289-4-7, Communication cables - Specifications for test methods - Part 4-7: Environmental test
methods - Damp heat, steady state
EN 50289-4-17, Communication cables - Specifications for test methods - Part 4-17: Test methods for UV
resistance evaluation of the sheath of electrical and optical fibre cable
EN 50290-1-1, Communication cables - Part 1-1: General
EN 50290-1-2, Communication cables - Part 1-2: Definitions
EN 50290-2-20:2016, Communication cables - Part 2-20: Common design rules and construction -
General
EN 50290-2-28, Communication cables - Part 2-28: Common design rules and construction - Filling
compounds for filled cables
EN 50290-4-1:2014, Communication cables - Part 4-1: General considerations for the use of cables -
Environmental conditions and safety aspects
EN 62230, Electric cables - Spark-test method (IEC 62230)
EN 60811-201, Electric and optical
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.