Connectors for electronic equipment - Product requirements - Part 2-109: Circular connectors - Detail specification for connectors with M 12 × 1 screw-locking, for data transmission frequencies up to 500 MHz

IEC 61076-2-109:2014 describes circular connectors with IP 65/IP 67 degree of protection and suitable for data transmission with frequencies up to 500 MHz. Applications include, but are not limited to, vision systems and data acquisition. These connectors consist of fixed and free connectors, either rewireable or non-rewireable, with M 12 x 1 screw-locking. Male connectors have round contacts ∅ 0,6 mm. This standard covers two different types of connectors, denominated X and H, with different contact arrangement, not mutually interchangeable, but with common ratings and purposes. Keywords: Connectors, Circular Connectors, Data transmission

Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 2-109: Rundsteckverbinder - Bauartspezifikation für Steckverbinder M 12 x 1 mit Schraubverriegelung für Datenübertragungen bis 500 MHz

Connecteurs pour équipements électroniques - Exigences de produit - Partie 2-109: Connecteurs circulaires - Spécification particulière relative aux connecteurs avec verrouillage à vis M 12 × 1, pour les transmissions de données à des fréquences jusqu’à 500 MHz

L'IEC 61076-2-109:2014 décrit des connecteurs circulaires avec un degré de protection IP 65/IP 67 et adaptés à une transmission de données à des fréquences jusqu'à 500 MHz. Les applications incluent, sans toutefois s'y limiter, les systèmes de vision et l'acquisition de données. Ces connecteurs se composent d'embases et de fiches, démontables ou non et sont équipés d'un système à vis M 12 x 1. Les connecteurs mâles possèdent des contacts arrondis de ∅ 0,6 mm. La présente norme couvre deux types différents de connecteurs, désignés X et H, avec différentes dispositions des contacts, non interchangeables, mais avec des caractéristiques assignées et des applications prévues communes. Mots-clés: Connecteurs, Connecteurs circulaires, Transmission de données

Konektorji za elektronsko opremo - Zahteve za izdelek - 2-109. del: Okrogli konektorji - Podrobna specifikacija za konektorje z vijačno zaporo m 12 x 1 za prenos podatkov s frekvencami do 500 MHz (IEC 61076-2-109:2014)

Standard EN IEC 61076-2-109 opisuje okrogle konektorje s stopnjo zaščite IP 65/IP 67, ki so primerni za prenos podatkov s frekvencami do 500 MHz. Med možne uporabe med drugim spadajo vidni sistemi in pridobivanje podatkov. Ti konektorji so sestavljeni iz pritrjenih in prostih konektorjev z možnostjo ponovnega ožičenja ali brez, z vijačno zaporo M 12 x 1. Moški konektorji imajo okrogle kontakte Ø 0,6 mm. Ta standard obravnava dva različna tipa konektorjev, označena z X in H, z različno razporeditvijo kontaktov, ki nista medsebojno zamenljiva, vendar imata skupne moči in namene.

General Information

Status
Published
Publication Date
28-Aug-2014
Withdrawal Date
11-Jun-2017
Technical Committee
Drafting Committee
Current Stage
6060 - Document made available - Publishing
Start Date
29-Aug-2014
Completion Date
29-Aug-2014
Standard
EN 61076-2-109:2014
English language
33 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2014
.RQHNWRUML]DHOHNWURQVNRRSUHPR=DKWHYH]DL]GHOHNGHO2NURJOL
NRQHNWRUML3RGUREQDVSHFLILNDFLMD]DNRQHNWRUMH]YLMDþQR]DSRURP[]D
SUHQRVSRGDWNRYVIUHNYHQFDPLGR0+] ,(&
Connectors for electronic equipment - Product requirements - Part 2-109: Circular
connectors - Detail specification for connectors with m 12 x 1 screw-locking, for data
transmissions with frequencies up to 500 mhz
/
Connecteurs pour équipements électroniques - Exigences de produit - Partie 2-109:
Connecteurs circulaires - Spécification particulière relative aux connecteurs avec
verrouillage à vis m 12 x 1, pour les transmissions de données à des fréquences jusqu'à
500 mhz
Ta slovenski standard je istoveten z: EN 61076-2-109:2014
ICS:
31.220.10 9WLþLLQYWLþQLFHNRQHNWRUML Plug-and-socket devices.
Connectors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 61076-2-109

NORME EUROPÉENNE
EUROPÄISCHE NORM
August 2014
ICS 31.220.10
English Version
Connectors for electronic equipment - Product requirements -
Part 2-109: Circular connectors - Detail specification for
connectors with M 12 × 1 screw-locking, for data transmission
frequencies up to 500 MHz
(IEC 61076-2-109:2014)
Connecteurs pour équipements électroniques - Exigences Steckverbinder für elektronische Einrichtungen -
de produit - Partie 2-109: Connecteurs circulaires - Produktanforderungen - Teil 2-109: Rundsteckverbinder -
Spécification particulière relative aux connecteurs avec Bauartspezifikation für Steckverbinder M 12 x 1 mit
verrouillage à vis M 12 × 1, pour les transmissions de Schraubverriegelung für Datenübertragungen bis 500 MHz
données à des fréquences jusqu'à 500 MHz (IEC 61076-2-109:2014)
(CEI 61076-2-109:2014)
This European Standard was approved by CENELEC on 2014-06-12. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61076-2-109:2014 E

Foreword
The text of document 48B/2369/FDIS, future edition 1 of IEC 61076-2-109, prepared by SC 48B
“Connectors” of IEC/TC 48 “Electromechanical components and mechanical structures for electronic
equipment” was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as
The following dates are fixed:
• latest date by which the document has to be (dop) 2015-03-12
implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2017-06-12
• latest date by which the national
standards conflicting with the
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 61076-2-109:2014 was approved by CENELEC as a
European Standard without any modification.

- 3 - EN 61076-2-109:2014
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu
Publication Year Title EN/HD Year
IEC 60050 Series International Electrotechnical Vocabulary - -
(IEV)
IEC 60068-1 2013 Environmental testing - EN 60068-1 2014
Part 1: General and guidance
IEC 60068-2-60 1995 Environmental testing - EN 60068-2-60 1996
Part 2: Tests - Test Ke: Flowing mixed gas
corrosion test
IEC 60352 Series Solderless connections EN 60352 series
IEC 60512 Series Connectors for electronic equipment - EN 60512-1 series
Tests and measurements
1) 1)
IEC 60512-29-100 -  Connectors for electronic equipment - EN 60512-29-100 -
Tests and measurements -
Part 29-100: Signal integrity tests
up to 500 MHz on M12 style connectors -
Tests 29a to 29g
IEC 60529 1989 Degrees of protection provided by EN 60529 1991
enclosures (IP Code) corr. May 1993
A1 1999 A1 2000
A2 2013 A2 2013
IEC 60603-7 2008 Connectors for electronic equipment - EN 60603-7 2009
Part 7: Detail specification for 8-way,
A1 2011 A1 2011
unshielded, free and fixed connectors
IEC 60603-7-1 -  Connectors for electronic equipment - EN 60603-7-1 -
Part 7-1: Detail specification for 8-way,
shielded, free and fixed connectors
IEC 60664-1 2007 Insulation coordination for equipment EN 60664-1 2007
within low-voltage systems -
Part 1: Principles, requirements and tests

1)
At draft stage.
IEC 60998-2-1 2002 Connecting devices for low-voltage EN 60998-2-1 2004
(mod) circuits for household and similar
purposes -
Part 2-1: Particular requirements for
connecting devices as separate entities
with screw-type clamping units
IEC 60999 Series Connecting devices - Electrical copper EN 60999 Series
conductors - Safety requirements for
screw-type and screwless-type clamping
units
IEC 61076-1 -  Connectors for electronic equipment - EN 61076-1 -
Product requirements -
Part 1: Generic specification
IEC 61076-2 2011 Connectors for electronic equipment - EN 61076-2 2011
Product requirements -
Part 2: Sectional specification for circular
connectors
IEC 61076-2-101 2012 Connectors for electronic equipment - EN 61076-2-101 2012
Product requirements -
Part 2-101: Circular connectors - Detail
specification for M12 connectors with
screw-locking
IEC 61984 2008 Connectors - Safety requirements and EN 61984 2009
tests
ISO 1302 -  Geometrical Product Specifications EN ISO 1302 -
(GPS) - Indication of surface texture in
technical product documentation
ISO/IEC 11801 2002 Information technology - Generic cabling - -
for customer premises
IEC 61076-2-109 ®
Edition 1.0 2014-05
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment – Product requirements –

Part 2-109: Circular connectors – Detail specification for connectors with

M 12 × 1 screw-locking, for data transmission frequencies up to 500 MHz

Connecteurs pour équipements électroniques – Exigences de produit –

Partie 2-109: Connecteurs circulaires – Spécification particulière relative aux

connecteurs avec verrouillage à vis M 12 × 1, pour les transmissions de

données à des fréquences jusqu’à 500 MHz

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX U
ICS 31.220.10 ISBN 978-2-8322-1541-8

– 2 – IEC 61076-2-109:2014 © IEC 2014
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 8
2 Normative references . 8
3 Technical information . 9
3.1 Terms and definitions . 9
3.2 Recommended method of termination . 9
3.2.1 General . 9
3.2.2 Number of contacts or contact cavities . 9
3.3 Ratings and characteristics . 9
3.4 Marking . 10
3.5 Safety aspects . 10
4 Dimensions . 10
4.1 General . 10
4.2 Survey of styles and variants . 10
4.3 Interface dimensions for connectors . 11
4.3.1 Interface dimensions for connector type X . 11
4.3.2 Interface dimensions for connector type H . 14
4.3.3 Pin front view of connectors and contact position . 14
4.4 Gauges . 15
4.4.1 Sizing gauges and retention force gauges . 15
5 Characteristics . 15
5.1 Climatic category . 15
5.2 Electrical . 15
5.2.1 Rated voltage – Rated impulse voltage – Pollution degree . 15
5.2.2 Voltage proof . 16
5.2.3 Current-carrying capacity . 16
5.2.4 Contact resistance . 16
5.2.5 Insulation resistance . 16
5.3 Mechanical . 16
5.3.1 IP degree of protection . 16
5.3.2 Mechanical operation . 16
5.3.3 Insertion and withdrawal forces . 17
5.3.4 Contact retention in insert . 17
5.3.5 Polarizing method . 17
5.3.6 Vibration (sinusoidal) . 17
5.3.7 Shock . 17
6 Test schedule . 18
6.1 General . 18
6.1.1 Introductory remarks . 18
6.1.2 Arrangement for contact resistance measurements . 18
6.1.3 Arrangement for dynamic stress tests (vibration) . 19
6.2 Test schedule . 20
6.2.1 Test group P – Preliminary . 20
6.2.2 Test group AP – Dynamic/ climatic . 21

IEC 61076-2-109:2014 © IEC 2014 – 3 –
6.2.3 Test group BP – Mechanical endurance . 23
6.2.4 Test group CP – Electrical load . 24
6.2.5 Test group DP – Chemical resistivity . 25
6.2.6 Test group EP – Connection method tests . 25
6.2.7 Test group FP – Electrical transmission requirements . 25
Annex A (informative) Contact and pair designation for balanced cabling . 29
A.1 Recommendation for cable connection . 29

Figure 1 – Interface dimensions for connectors type X with female contacts . 11
Figure 2 – Interface dimensions for connectors type X with male contacts . 12
Figure 3 – Interface dimensions for connectors type H with male contacts . 14
Figure 4 – Gauge dimensions . 15
Figure 5 – Contact resistance arrangement . 19
Figure 6 – Dynamic stress test arrangement . 19

Table 1 – Contact termination . 9
Table 2 – Interface dimensions, connector type X with female contacts . 12
Table 3 – Interface dimensions, connector type X with male contacts . 13
Table 4 – Interface dimensions for connectors type H with male contacts . 14
Table 5 – Gauges . 15
Table 6 – Climatic category . 15
Table 7 – Rated voltage – Impulse voltage – Pollution degree . 16
Table 8 – Voltage proof, r.m.s. withstand voltages . 16
Table 9 – Number of mechanical operations . 17
Table 10 – Insertion and withdrawal forces . 17
Table 11 – Number of test specimens . 18
Table 12 – Test group P . 20
Table 13 – Test group AP (1 of 2) . 21
Table 14 – Test group BP . 23
Table 15 – Test group CP . 24
Table 16 – Test group DP . 25
Table 17 – Test group EP . 25
Table 18 – Test group FP (1 of 2) . 27
Table A.1 – Example of contact and pair designation for balanced cabling
(informative) . 29

– 4 – IEC 61076-2-109:2014 © IEC 2014
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
CONNECTORS FOR ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –
Part 2-109: Circular connectors – Detail specification for
connectors with M 12 x 1 screw-locking, for data
transmission frequencies up to 500 MHz

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
International Standard IEC 61076-2-109 has been prepared by subcommittee 48B:
Connectors, of IEC technical committee 48: Electromechanical components and mechanical
structures for electronic equipment.
This first edition of IEC 61076-2-109 cancels and relaces IEC PAS 61076-2-109, published in
2010.
The text of this standard is based on the following documents:
FDIS Report on voting
48B/2369/FDIS 48B/2382/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.

IEC 61076-2-109:2014 © IEC 2014 – 5 –
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 61076 series, published under the general title Connectors for
electronic equipment – Product requirements, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
– 6 – IEC 61076-2-109:2014 © IEC 2014
INTRODUCTION
The International Electrotechnical Commission (IEC) draws attention to the fact that it is
claimed that compliance with this document may involve the use of a patent concerning
connector given in 4.3.2.
IEC takes no position concerning the evidence, validity and scope of this patent right.
The holder of this patent right has assured the IEC that he/she is willing to negotiate licences
free of charge with applicants throughout the world. In this respect, the statement of the
holder of this patent right is registered with IEC. Information may be obtained from:
Tyco Electronics Corporation
Licensing Council, Tyco Electronics Technology Resources Inc.
4550 New Linden Hill Road, Suite 140
Wilmington, DE 19808
USA
Attention is drawn to the possibility that some of the elements of this document may be the
subject of patent rights other than those identified above. IEC shall not be held responsible for
identifying any or all such patent rights.
ISO (www.iso.org/patents) and IEC (http://patents.iec.ch) maintain on-line data bases of
patents relevant to their standards. Users are encouraged to consult the data bases for the
most up to date information concerning patents.

IEC 61076-2-109:2014 © IEC 2014 – 7 –

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC 61076-2-109 Ed. 1.0
IEC SC 48B – Connectors
ELECTRONIC COMPONENTS
in accordance with IEC 61076-1
Circular connectors
M12 × 1 mm 2 to 8 ways, for data
transmission frequencies up to 500 MHz

Pin and socket connectors with round

contact
Rewireable – Non-rewirable
Free cable connectors
Straight and right angle connectors

Fixed connectors
Type X
Flange mounting
Rear mounting
Single hole mounting
Type H
IEC  1225/14
– 8 – IEC 61076-2-109:2014 © IEC 2014
CONNECTORS FOR ELECTRONIC EQUIPMENT –
PRODUCT REQUIREMENTS –
Part 2-109: Circular connectors – Detail specification for
connectors with M 12 x 1 screw-locking, for data
transmission frequencies up to 500 MHz

1 Scope
This part of IEC 61076 describes circular connectors with IP 65/IP 67 degree of protection
and suitable for data transmission with frequencies up to 500 MHz. Applications include, but
are not limited to, vision systems and data acquisition. These connectors consist of fixed and
free connectors, either rewireable or non-rewireable, with M12 x 1 screw-locking. Male
connectors have round contacts ∅ 0,6 mm.
This standard covers two different types of connectors, denominated X and H, with different
contact arrangement, not mutually interchangeable, but with common ratings and purposes.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60050 (all parts), International Electrotechnical Vocabulary (available at
http://www.electropedia.org)
IEC 60068-1:2013, Environmental testing – Part 1: General and guidance
IEC 60068-2-60:1995, Environmental testing – Part 2: Tests – Test Ke: Flowing mixed gas
corrosion test
I
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...