Abstract

This document specifies requirements for phased array ultrasonic examination of steel castings with low ultrasonic attenuation. It is applicable to ferritic, bainitic and martensitic microstructures. It specifies the registration levels and acceptance criteria.
This document is applicable to the ultrasonic examination of steel castings with a wall thickness of 600 mm or less.
For higher wall thicknesses, special agreements apply regarding the test procedure and recording levels.
This document does not apply to austenitic steels and cast irons, lamellar graphite and spheroidal cast irons and welded assemblies. For other ferrous materials, this document gives guidance. The registration levels and acceptance criteria are to be adapted.
In this document, phased array is used both for phased array technique and TFM technique.

Status
Published
Publication Date
10-Nov-2026
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
11-Nov-2026
Due Date
15-Mar-2027
Completion Date
15-Mar-2027

Buy Documents

EN 12680-4 is a CEN European Standard for phased array ultrasonic testing of steel castings. It specifies how to examine steel castings with low ultrasonic attenuation, including the registration levels and acceptance criteria, and it is written for people who order, perform, specify or evaluate ultrasonic inspection of castings.

What does EN 12680-4 specify?

EN 12680-4 specifies phased array ultrasonic examination for steel castings with ferritic, bainitic and martensitic microstructures. It applies to castings with a wall thickness of 600 mm or less, and it sets out how the inspection, recording and acceptance rules are to be handled in practice.

The standard excludes austenitic steels, cast irons, lamellar graphite and spheroidal cast irons, and welded assemblies. For other ferrous materials, it gives guidance and says the registration levels and acceptance criteria have to be adapted.

The document is organized into clauses on scope, references, terms, ordering, personnel, equipment, preparation, time base and sensitivity, operating mode, interpretation and analysis, and the test report. It has one informative annex with examples of reference blocks.

AnnexWhat it covers
Annex AExamples of reference blocks

What are the key requirements of EN 12680-4?

Ordering, scope and procedure

EN 12680-4 requires the buyer and manufacturer to agree the examination volume, the casting areas to be covered, the reference and calibration blocks, access conditions, surface condition, temperature, and the stage of manufacture or operation when testing will take place. In practice, this means the inspection need is defined before the work starts, so the right areas, setup and constraints are fixed in the order.

A written test procedure is mandatory. It must cover the purpose and scope of the test, operating technique, severity levels, qualification and training, equipment requirements, blocks, settings and checks, surface and access conditions, scan plan, evaluation levels, acceptance or registration levels, reporting, and environmental and safety issues.

Personnel and equipment

Personnel performing the test must be qualified for non-destructive testing in accordance with this document and with EN ISO 9712, or an equivalent standard in the foundry sector. They also need training and practical experience in phased array technique and total focusing technic (TFM), because the standard expects operators to set up, read and interpret these images correctly.

The equipment has to meet EN ISO 18563-1, EN ISO 18563-2 and EN ISO 18563-3 where applicable. The ultrasonic instrument must be able to create beams matched to the part geometry, the material structure and the required severity level, and it may need to show both conventional electronic scanning and TFM data at the same time.

Preparing the scan

Before testing, the equipment has to be checked, including the channels, probes and cables. The check is daily and uses reference blocks made for that purpose; if a component fails, the system is corrected and re-verified.

EN 12680-4 also requires a scan plan. The plan defines the scan faces, the electronic scans, the beams to be used, and the mechanical movement of the probes. The plan has to ensure the full volume is covered, which matters because missed overlap or poor positioning can leave uninspected zones.

The standard sets practical limits for surface condition, curvature and temperature. The scanning surface must be clean and suitable for coupling, the probe contact must fit the curvature closely, and the usual surface temperature range is 0 °C to 50 °C unless special high-temperature equipment is used.

Reference blocks, sensitivity and checks

The suitability of the material for phased array ultrasonic examination is checked by comparing the echo from a side-drilled hole with the background noise. That comparison is used to judge whether the material can be tested reliably at the required thickness range.

Time base and sensitivity are set before each test, and a change in configuration requires a new setting. EN 12680-4 also requires the settings to be checked at the start and end of the inspection, with corrections if the deviation exceeds the document’s limits. For the reader, this means the inspection is not just “set once and run”; the settings have to be confirmed and, if needed, repeated.

Reference blocks are used to check coverage and sensitivity adjustment. The standard gives the required material match and the minimum number of reflectors in the block according to wall thickness, and Annex A shows example layouts.

Operating mode, data and acceptance

The operating method depends on casting shape and possible discontinuities, so the manufacturer specifies the procedure. Where possible, both sides should be examined; if only one side is inspected, a reduced dead zone or double probe is used to improve near-surface detection.

EN 12680-4 says local image recording is required for severity level 1 areas, and finishing welds deeper than 50 mm need additional inclined transverse wave imaging. It also states that TFM is particularly useful for sizing and identifying indications, and that position-encoded acquisition can store A-scan data and configuration parameters for later review.

Interpretation follows a clear sequence: assess data quality, identify relevant indications, classify and size them, and compare them with the acceptance criteria. Tables 6 and 7 set the severity levels, acceptability limits and recording levels by wall thickness and area type, so the inspector can decide what must be recorded and what is acceptable.

What terms does EN 12680-4 define?

  • Ultrasonic instrument - a generic term used for both the Phased Array instrument and the TFM instrument.
  • Phased array image - a one- or two-dimensional display built from collected phased array data.
  • Indication or phased-array indication - a pattern or disturbance in the phased array image that may need further evaluation.
  • Phased array setup - the probe arrangement, including probe characteristics, probe position and number of probes.
  • Probe position (PP) - the position of the probe reference point relative to the part reference point.
  • Region of interest (ROI) - the two- or three-dimensional test region for which the image is computed.
  • Total focusing technic (TFM) - synthetic focusing that reconstructs an image inside the ROI by processing transmitter-receiver data.
  • Equivalent discontinuity echo size - the smallest indication to be recorded during evaluation, usually expressed as the equivalent diameter of a side-drilled hole.

Who uses EN 12680-4?

EN 12680-4 is used by foundries, casting manufacturers, ultrasonic testing operators, NDT supervisors, quality managers and customers who specify acceptance criteria for steel castings. It supports the whole chain from ordering and defining the examination area to performing the scan, judging indications and writing the report.

It is especially relevant where castings are inspected for internal soundness before delivery or before further processing. The standard also helps buyers and suppliers agree the procedure, the required surface condition, the inspection coverage and the reporting format.

Which standards are used with EN 12680-4?

StandardWhat it contributes
EN 12680-1Related requirements and terminology for steel castings for general purposes
EN ISO 5577Ultrasonic testing vocabulary
EN ISO 9712Qualification and certification of NDT personnel
EN ISO 16810General principles for ultrasonic testing
EN ISO 18563-1Characterization and verification of ultrasonic phased array instruments
EN ISO 18563-2Characterization and verification of phased array array probes
EN ISO 18563-3Characterization and verification of complete phased array systems
EN ISO 23243Ultrasonic testing with arrays vocabulary
EN 12680-2Companion part for highly stressed steel castings
EN 12680-3Companion part for spheroidal graphite cast iron castings

What does the EN 12680-4 document contain?

EN 12680-4 contains the inspection rules, setup requirements, sensitivity setting approach, verification checks, operating modes, interpretation method, acceptance limits and reporting content needed for phased array ultrasonic testing of steel castings. It includes tables for mechanical scan step, material testability, correction limits, reflector counts, operating recommendations, acceptability limits and recording levels.

The document also includes figures for electronically covered area and for dividing the wall section into rim and core zones. Annex A gives example reference block layouts, which are used to support calibration, coverage checks and sensitivity adjustment during inspection.

Buy Documents

Get Certified

Connect with accredited certification bodies for this standard

Element Materials Technology

Materials testing and product certification.

UKAS United Kingdom Verified

Inštitut za kovinske materiale in tehnologije

Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

EN 12680-4:2026 is a standard published by the European Committee for Standardization (CEN). Its full title is "Founding - Ultrasonic testing - Part 4: Phased array ultrasonic testing of steel castings". This standard covers: This document specifies requirements for phased array ultrasonic examination of steel castings with low ultrasonic attenuation. It is applicable to ferritic, bainitic and martensitic microstructures. It specifies the registration levels and acceptance criteria. This document is applicable to the ultrasonic examination of steel castings with a wall thickness of 600 mm or less. For higher wall thicknesses, special agreements apply regarding the test procedure and recording levels. This document does not apply to austenitic steels and cast irons, lamellar graphite and spheroidal cast irons and welded assemblies. For other ferrous materials, this document gives guidance. The registration levels and acceptance criteria are to be adapted. In this document, phased array is used both for phased array technique and TFM technique.

This document specifies requirements for phased array ultrasonic examination of steel castings with low ultrasonic attenuation. It is applicable to ferritic, bainitic and martensitic microstructures. It specifies the registration levels and acceptance criteria. This document is applicable to the ultrasonic examination of steel castings with a wall thickness of 600 mm or less. For higher wall thicknesses, special agreements apply regarding the test procedure and recording levels. This document does not apply to austenitic steels and cast irons, lamellar graphite and spheroidal cast irons and welded assemblies. For other ferrous materials, this document gives guidance. The registration levels and acceptance criteria are to be adapted. In this document, phased array is used both for phased array technique and TFM technique.

EN 12680-4:2026 is classified under the following ICS (International Classification for Standards) categories: 77.140.80 - Iron and steel castings. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 12680-4:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 ultrasonic instrument
  • 3.2 phased array image
  • 3.3 indication
  • 3.4 phased array setup
  • 3.5 probe position
  • 3.6 scan increment
  • 3.7 active aperture
  • 3.8 electronically covered area
  • 3.9 total focusing technique
  • 3.10 region of interest
  • 3.11 grid
  • 3.12 imaging path
  • 3.13 operating mode
  • 3.14 equivalent discontinuity echo size
  • 5 L-scan presentation
  • 4 Requirements before ordering
  • 4.1 Order information
  • 4.2 Scope of examination
  • 4.3 Test procedure
  • 5 Personnel qualification
  • 6 Equipment
  • 6.1 General
  • 6.2 Ultrasonic instrument
  • 6.3 Probes
  • 6.4 Scanning mechanisms
  • 7 Preparation before testing
  • 7.1 Equipment checking
  • 7.2 Test and scan parameters
  • 7.3 Geometric considerations
  • 7.4 Preparation of scanning surfaces
  • 7.5 Temperature
  • 7.6 Coupling medium
  • 7.7 Suitability of material for phased array ultrasonic examination
  • 8 Time base and sensitivity settings
  • 8.1 Parameters
  • 8.2 Parameters checking
  • 8.3 Reference blocks
  • 9 Test operating mode
  • 9.1 Requirements
  • 9.2 Recommendations
  • 9.3 Data acquisition with position encoder(s)
  • 10 Interpretation and analysis of phased-array data
  • 10.1 General
  • 10.2 Assessing the quality of phased-array ultrasonic inspection data
  • 10.3 Identification of relevant (or true) indications
  • 10.4 Classification and sizing of relevant indications
  • 10.5 Recording of data collected
  • 10.6 Areas of the wall section
  • 10.7 Severity levels
  • 11 Test report
  • Annex A
  • Bibliography

1 Scope

This document specifies requirements for phased array ultrasonic examination of steel castings with low ultrasonic attenuation. It is applicable to ferritic, bainitic and martensitic microstructures. It specifies the registration levels and acceptance criteria.

This document is applicable to the ultrasonic examination of steel castings with a wall thickness of 600 mm or less.

For higher wall thicknesses, special agreements apply regarding the test procedure and recording levels. This document does not apply to austenitic steels and cast irons, lamellar graphite and spheroidal cast irons and welded assemblies. For other ferrous materials, this document gives guidance. The registration levels and acceptance criteria are to be adapted.

In this document, phased array is used both for phased array technique and TFM technique.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12680-1, Founding — Ultrasonic testing — Part 1: Steel castings for general purposes EN ISO 5577, Non-destructive testing — Ultrasonic testing — Vocabulary (ISO 5577) EN ISO 9712, Non-destructive testing — Qualification and certification of NDT personnel (ISO 9712) EN ISO 16810, Non-destructive testing — Ultrasonic testing — General principles (ISO 16810) EN ISO 18563-1, Non-destructive testing — Characterization and verification of ultrasonic phased array equipment — Part 1: Instruments (ISO 18563-1) EN ISO 18563-2, Non-destructive testing — Characterization and verification of ultrasonic phased array equipment — Part 2: Array probes (ISO 18563-2) EN ISO 18563-3, Non-destructive testing — Characterization and verification of ultrasonic phased array equipment — Part 3: Complete systems (ISO 18563-3) EN ISO 23243, Non-destructive testing — Ultrasonic testing with arrays — Vocabulary (ISO 23243)

3 Terms and definitions

For the purposes of this document, the terms and definitions given in EN ISO 5577, EN ISO 23243 and EN 12680-1 and the following apply.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https://www.iso.org/obp/
  • IEC Electropedia: available at https://www.electropedia.org/

3.1 ultrasonic instrument

generic term used for both Phased Array instrument and TFM instrument

SIST EN 12680-4:2027 EN 12680-4:2026 (E)

3.2 phased array image

one- or two-dimensional display, constructed from the collected information of phased array operation [SOURCE: EN ISO 23243:2020, 3.3.2.8]

3.3 indication

phased-array indication pattern or disturbance in the phased array image (3.2) which can need further evaluation

3.4 phased array setup

probe arrangement defined by probe characteristics (e.g. frequency, probe element size, beam angle, wave mode), probe position (3.5), and the number of probes [SOURCE: EN ISO 23243:2020, 3.3.1.3]

3.5 probe position

PP position of the probe reference point relative to the part reference point Note 1 to entry: The position of the probe reference point depends on the equipment used and shall be known by the operator to position the indications.

3.6 scan increment

distance between successive data collection points in the direction of scanning (mechanically or electronically) [SOURCE: EN ISO 23243:2020, 3.3.1.5]

3.7 active aperture

group of active elements operated together when transmitting and/or receiving [SOURCE: EN ISO 23243:2020, 3.2.1.21]

3.8 electronically covered area

width of the area covered during an electronic scanning and measured, for example, between the axis of the first beam and the axis of the last beam of an electronic linear scanning Note 1 to entry: See Figure 1.

3.9 total focusing technique

TFM synthetic focusing which consists of a reconstruction, inside a ROI (3.10), to focus at many points which form a grid (3.11), by processing part or all A-scan information of the applicable transmitter-receiver combinations, taking into account the imaging path (3.12) [SOURCE: EN ISO 23243:2020, 3.3.1.35, modified – Notes 1 to 3 to entry have been deleted.]

SIST EN 12680-4:2027 EN 12680-4:2026 (E)

3.10 region of interest

ROI two- or three-dimensional region, related to the test volume, for which the image is computed [SOURCE: EN ISO 23243:2020, 3.3.2.4, modified – Notes 1 to entry has been deleted.]

3.11 grid

collection of points in the ROI (3.10) for which the image is calculated and stored, defined by the position and relative distance between the points in a specified direction [SOURCE: EN ISO 23243:2020, 3.3.2.5 modified – Notes 1 to 4 to entry have been deleted.]

3.12 imaging path

path that ultrasonic waves travel from transmitter to image point and from image point to receiver which is taken into account by the imaging algorithm including refraction(s), reflection(s) and/or mode conversion(s), if applicable [SOURCE: EN ISO 23243:2020, 3.3.1.38]

3.13 operating mode

combination of ultrasound beams created by an array probe, e.g. fixed angle, L-scan, S-scan, Total Focusing Technique (TFM)

3.14 equivalent discontinuity echo size

smallest indication to be recorded during the evaluation phase of an ultrasound examination, usually expressed as the equivalent diameter of the side drilled hole [SOURCE: EN 12680-1:2025, modified — side drilled hole instead of flat bottom hole]

SIST EN 12680-4:2027 EN 12680-4:2026 (E)

Key 1 array probe 2 active aperture (grey elements) 3 moving active aperture of the electronic linear scanning 4 summed A-scan for a given shot

5 L-scan presentation

6 electronic scanning resolution 7 electronically covered area Figure 1 — Electronically covered area

SIST EN 12680-4:2027 EN 12680-4:2026 (E)

4 Requirements before ordering

4.1 Order information

The following information shall be available at the time of inquiry and order (see also EN ISO 16810:2024, Clause 5):

a) the areas of the casting and the number or percentage of castings to which phased array ultrasonic testing requirements apply (examination volume, extent of examination); b) calibration and reference blocks used; c) requirements for access, surface conditions and temperature; d) the stage of manufacture or operation at which testing is to be carried out; e) if there are additional requirements for the test procedure, see also Clause 7.

4.2 Scope of examination

The casting shall be tested so that the agreed areas are covered (insofar as this is possible from the shape of the casting) by the use of the best applicable test technique. For wall thicknesses greater than 600 mm, agreement shall be made between the manufacturer and the customer on the severity levels, test procedure and the recording of the test results.

4.3 Test procedure

A written test procedure is required.

The procedure includes at least the following information:

a) purpose and scope of testing; b) operating techniques; c) severity levels; d) personnel qualification and training requirements; e) equipment requirements (including, but not limited to, frequency, sampling frequency, pitch between elements, element size); f) reference and/or calibration blocks; g) equipment settings and checks; h) accessibility and surface conditions; i) scan plan; j) indication evaluation levels; k) acceptance and/or registration levels; l) reporting requirements;

SIST EN 12680-4:2027 EN 12680-4:2026 (E) m) environmental and safety issues.

5 Personnel qualification

Personnel performing non-destructive testing shall be qualified in accordance with this document and have an appropriate level of qualification in ultrasonic testing in accordance with EN ISO 9712 or an equivalent standard in the foundry sector.

In addition to general knowledge of ultrasonic inspection of castings, operators shall also be familiar with and have training and practical experience in the use of the phased array technique and total focusing technique (TFM).

6 Equipment

6.1 General

Ultrasonic inspection equipment used for phased-array testing shall comply with the requirements of EN ISO 18563-1, EN ISO 18563-2 and EN ISO 18563-3 where applicable.

6.2 Ultrasonic instrument

The ultrasonic instrument shall be able to manage the probe(s) so as to generate beams adapted to the geometry of the part, the material structure, and the required severity level. The ultrasonic instrument shall be able to generate several settings simultaneously, in particular for monitoring both the background echo and the appearance of a defect echo. Depending on the application (for example sponge shrinkages), it may be necessary to display the TFM image at the same time as the electronic scanning in order to ensure the correct positioning of the region of interest (ROI) and acquire simultaneously electronic scanning and TFM data. It is recommended to use an A-scan sampling frequency of at least six times the nominal frequency of the probe.

6.3 Probes

Both longitudinal waves and transverse waves can be used.

The probe shall take into account the surface curvature (e.g. curved wedge, flexible probe …) to transmit the ultrasonic signal into the part.

The number of dead elements on each active aperture shall be a maximum of 1 in 16 and they shall not be adjacent. For active aperture using fewer than 16 elements, no dead elements are permitted unless adequate performance is demonstrated.

6.4 Scanning mechanisms

To ensure consistency of images (collected data), guidance devices and scanning encoders can be used to communicate the position of the probe relative to an origin point in the part at any time.

7 Preparation before testing

7.1 Equipment checking

The equipment necessary to perform the tests shall respect the requirements in the testing specifications. It should be verified that all used channels, probes and cables of the phased array combined system are functional. To do this, it shall be checked daily using reference blocks provided for this purpose (see 8.3).

SIST EN 12680-4:2027 EN 12680-4:2026 (E) If a system component fails, corrective action shall be taken and the system shall be re-verified according to EN ISO 18563-3.

7.2 Test and scan parameters

A scan plan shall be provided, including:

a) the scan faces of the areas to be tested; b) electronic scannings; c) the ultrasound beams generated (type of wave, shape of the beam, number of laws, distribution and grouping of elements); d) the mechanical movements (directions, sweep and increment) of the probe(s) as well as their relative positions on the part.

...