EN 12681-2:2026
(Main)Founding - Radiographic testing - Part 2: Techniques with digital detectors
- Abstract
This document gives specific procedures for industrial X-ray and gamma radiography for discontinuity detection purposes, using NDT (non-destructive testing) digital X-ray image detectors. This part of the EN 12681 series specifies the requirements for digital radiographic testing by either computed radiography (CR) or radiography with digital detector arrays (DDA) of castings.
Digital detectors provide a digital grey value image which can be viewed and evaluated using a computer.
NOTE This part of the EN 12681 series complies with EN ISO 16371-2 for CR. Some clauses and annexes are taken from EN ISO 17636-2.
This part of the EN 12681 series specifies the recommended procedure for detector selection and radiographic practice. Selection of computer, software, monitor, printer and viewing conditions are important but are not the main focus of this document. The procedure specified in this document provides the minimum requirements for radiographic practice which permit exposure and acquisition of digital images with equivalent sensitivity for detection of imperfections as film radiography, as specified in EN 12681-1.
This document does not consider radiographic or radioscopic fitness for purpose testing as applied for specific castings based on manufacturer’s internal requirements and procedures.
The requirements on image quality in testing class A and B testing of Annex A consider the good workmanship quality for general casting applications as also required in EN 12681-1 for film radiography.
The testing classes AA and BA reflect the quality requirements of current automated and semi-automated radiographic testing systems with DDAs and computer- or operator-based image evaluation, and mini- or micro-focus tubes (spot size ≤ 1 mm) with reduced requirements to the unsharpness, but unchanged requirements to contrast sensitivity as also required in EN 12681-1 for film radiography.
The specified procedures are applicable to castings produced by any casting process, especially for steels, cast irons, aluminium, cobalt, copper, magnesium, nickel, titanium, zinc and any alloys of them.
This document does not apply to:
- the testing of welded joints (see EN ISO 17636-2);
- film radiography (see EN 12681-1);
- real time testing with radioscopy (see EN 13068-1; radioscopy with image intensifiers).
- Status
- Published
- Publication Date
- 10-Nov-2026
- Technical Committee
- CEN/TC 190 - Foundry technology
- Drafting Committee
- CEN/TC 190/WG 10 - Testing for inner discontinuities
- Current Stage
- 6060 - Definitive text made available (DAV) - Publishing
- Start Date
- 11-Nov-2026
- Due Date
- 27-Jul-2027
- Completion Date
- 27-Jul-2027
EN 12681-2:2026 is a CEN standard for industrial X-ray and gamma radiographic testing of castings using digital detectors. It specifies procedures for computed radiography (CR) and radiography with digital detector arrays (DDA), with a focus on discontinuity detection, image quality and acceptance criteria. In practice, it is aimed at foundries, NDT providers, and quality teams that need a digital alternative to film radiography for castings.
What does EN 12681-2:2026 specify?
EN 12681-2:2026 specifies the minimum procedures and image-quality conditions for digital radiographic testing of castings. It covers how to set up the exposure, choose the detector and radiation source, process the image, evaluate quality, and document the result.
The scope is limited to industrial X-ray and gamma radiography with NDT digital X-ray image detectors. It explicitly separates this method from welded-joint testing, film radiography, and real-time radioscopy with image intensifiers.
The document is organized as follows:
| Annex | What it covers |
|---|---|
| Annex A | Minimum image quality values |
| Annex B | Severity levels for steel castings |
| Annex C | Severity levels for cast iron castings |
| Annex D | Severity levels for aluminium and magnesium alloy castings |
| Annex E | Severity levels for titanium and titanium alloy castings |
| Annex F | Determination of basic spatial resolution |
| Annex G | Determination of minimum grey values for CR practice |
| Annex H | Grey values, general remarks |
| Annex I | Calculation of maximum X-ray tube voltages in Figure 13 |
| Annex J | Significant technical changes from the previous edition |
What are the key requirements of EN 12681-2:2026?
EN 12681-2:2026 sets out how to obtain radiographs that can reveal casting discontinuities with sensitivity comparable to film radiography. The most important points are the testing class, the exposure geometry, the detector/image-quality limits, and the way the final result is documented.
Testing classes and compensation rules
Clause 5 divides the work into testing class A and testing class B, with separate basic and improved versions for automated DDA-based testing. Annex A links those classes to the required image quality.
The standard also introduces compensation principles CP I, CP II and CP III. In practice, this means that if one parameter is weaker than desired - for example contrast, detector sharpness, or pixel correction effects - the test can still be acceptable only if the image signal-to-noise ratio (SNR) is raised enough to recover the required detection sensitivity.
Preparation, agreements and personnel
Clause 6 requires radiation protection measures, surface preparation when surface roughness would hide small discontinuities, and testing after the final stage of manufacture unless agreed otherwise. It also says several items should be agreed before testing starts, including the manufacturing stage, extent of testing, test areas, surface condition, testing class, detector position plan, image quality requirements and acceptance criteria.
Personnel are expected to be qualified to EN ISO 9712 or an equivalent level, with additional training in digital industrial radiography. For buyers and quality managers, this means the order should define the test conditions clearly and confirm that operators are qualified for digital work, not only general NDT.
Test arrangements, source choice and geometry
Clauses 7, 8, 9, 10 and 11 define the practical radiography set-up. The standard gives separate arrangements for single-wall, double-wall and complex geometries, and it distinguishes between CR and DDA use. It also gives guidance on tube voltage, gamma sources, metal screens, scatter reduction and the source-to-object distance.
This matters because image unsharpness, contrast and coverage depend on geometry as much as on detector type. The document limits source angle in the region of interest, addresses backscatter with shielding checks, and requires the source and detector positions to be identified on the plan or in the photo documentation.
Image processing, viewing and storage
Clauses 12 and 13 control scan/read-out, DDA correction, bad-pixel interpolation, image processing, monitor viewing and data storage. DDA systems must be corrected with background and gain images, and the bad-pixel map must be documented. Digital images are to be viewed under controlled conditions and stored at full detector resolution with lossless compression and a backup strategy.
For CR, Annex G is important because it links minimum grey values to the required SNR for a specific IP and scanner set-up. In practice, that lets users specify a measurable acceptance level for inhomogeneous parts where SNR alone is difficult to determine.
Image quality and acceptance
Clause 16 and Annex A define image quality using IQIs, minimum image quality values, minimum normalized SNR, and basic spatial resolution. The standard uses wire IQIs, step/hole IQIs and duplex wire IQIs to prove both contrast sensitivity and spatial resolution. Annex F describes how to determine basic spatial resolution, and Annex G explains the CR grey-value method.
Clauses 18 and Annexes B to E set acceptance by severity levels for specific materials. The castings are judged against digital reference images, and different zones of a wall section can have different acceptance levels. Clause 19 then requires a test report with the key exposure, detector, processing and evaluation data.
What terms does EN 12681-2:2026 define?
- Computed radiography (CR) - a storage phosphor imaging plate system that converts the latent image into a digital image by read-out.
- Digital detector array system (DDA system) - an electronic detector that turns radiation into a digitized image for computer display.
- Image quality indicator (IQI) - a test piece used to prove image quality, contrast sensitivity and spatial resolution.
- Signal-to-noise ratio (SNR) - the ratio of mean linearized grey value to its standard deviation in a region of interest.
- Basic spatial resolution (SR) - the smallest geometric detail the detector or digital image can resolve, linked to detector unsharpness.
- Grey value (GV) - the numeric value of a pixel in a digital image.
- Source-to-detector distance (SDD) - the distance from the source to the detector along the beam axis.
Who uses EN 12681-2:2026?
EN 12681-2:2026 is used by foundries, NDT laboratories, inspection bodies, and quality teams working on castings. It is relevant to operators setting up digital radiography, engineers defining exposure geometry, and buyers or specifiers writing acceptance requirements for cast steel, cast iron, aluminium, magnesium and titanium parts.
It is also useful for serial production, where automated or semi-automated DDA systems are used and the test plan, detector position and image-quality verification need to be repeatable.
What changed in EN 12681-2:2026 from the previous edition?
EN 12681-2:2026 supersedes EN 12681-2:2017. Annex J highlights these main changes:
- updated normative references, including EN IEC 62976
- terminology aligned so the document uses “testing class”
- revised test-arrangement wording and added figure captions
- updated tube-voltage guidance and exception rules for Se 75
- revised DDA wording from “calibration” to “correction”
- added an exception for energy-resolving detectors in the SNR requirement clause
- updated Annexes B to E to the latest ASTM reference-image editions
- revised Annex F and Annex G
- new Annexes I and J
Which standards are used with EN 12681-2:2026?
| Standard | What it contributes |
|---|---|
| EN 14784-1 | Classification and performance evaluation of CR systems |
| EN ISO 9712 | Qualification and certification of NDT personnel |
| EN ISO 17636-2:2022 | Digital radiography procedures for welds; also the model for some clauses and annexes |
| EN ISO 19232-1 | Wire-type IQIs for image quality value determination |
| EN ISO 19232-2 | Step/hole-type IQIs for image quality value determination |
| EN ISO 19232-4 | Experimental evaluation of image quality values and tables |
| EN ISO 19232-5 | Duplex wire IQIs for unsharpness and basic spatial resolution |
| ISO 5576 | Vocabulary for industrial X-ray and gamma-ray radiology |
| EN 12681-1 | Film-radiography counterpart and sensitivity benchmark |
| EN 14784-2 | CR reference named in the scope note |
| EN ISO 16371-2 | CR reference named in the scope note |
| EN 13068-1 | Radioscopy reference for the excluded real-time method |
What does the EN 12681-2:2026 document contain?
EN 12681-2:2026 contains exposure geometry rules, source and detector positioning guidance, scatter-control measures, image-processing requirements, viewing conditions and storage rules. It also includes figures for single-wall and double-wall arrangements, complex geometries and a nomogram for minimum source-to-object distance, plus a figure-based guide for maximum tube voltage.
The annexes add the practical measurement tools behind the rules: minimum IQI values, severity-level tables by material, basic spatial-resolution measurement, and CR grey-value calibration. Together, these sections let users set up digital casting radiography, verify image quality and record results in a consistent way.
Relations
- Replaces
EN 12681-2:2017 - Founding - Radiographic testing - Part 2: Techniques with digital detectors - Effective Date
- 02-Feb-2023
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
- Effective Date
- 18-Nov-2026
Get Certified
Connect with accredited certification bodies for this standard

Element Materials Technology
Materials testing and product certification.

Inštitut za kovinske materiale in tehnologije
Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.
Sponsored listings
Frequently Asked Questions
EN 12681-2:2026 is a standard published by the European Committee for Standardization (CEN). Its full title is "Founding - Radiographic testing - Part 2: Techniques with digital detectors". This standard covers: This document gives specific procedures for industrial X-ray and gamma radiography for discontinuity detection purposes, using NDT (non-destructive testing) digital X-ray image detectors. This part of the EN 12681 series specifies the requirements for digital radiographic testing by either computed radiography (CR) or radiography with digital detector arrays (DDA) of castings. Digital detectors provide a digital grey value image which can be viewed and evaluated using a computer. NOTE This part of the EN 12681 series complies with EN ISO 16371-2 for CR. Some clauses and annexes are taken from EN ISO 17636-2. This part of the EN 12681 series specifies the recommended procedure for detector selection and radiographic practice. Selection of computer, software, monitor, printer and viewing conditions are important but are not the main focus of this document. The procedure specified in this document provides the minimum requirements for radiographic practice which permit exposure and acquisition of digital images with equivalent sensitivity for detection of imperfections as film radiography, as specified in EN 12681-1. This document does not consider radiographic or radioscopic fitness for purpose testing as applied for specific castings based on manufacturer’s internal requirements and procedures. The requirements on image quality in testing class A and B testing of Annex A consider the good workmanship quality for general casting applications as also required in EN 12681-1 for film radiography. The testing classes AA and BA reflect the quality requirements of current automated and semi-automated radiographic testing systems with DDAs and computer- or operator-based image evaluation, and mini- or micro-focus tubes (spot size ≤ 1 mm) with reduced requirements to the unsharpness, but unchanged requirements to contrast sensitivity as also required in EN 12681-1 for film radiography. The specified procedures are applicable to castings produced by any casting process, especially for steels, cast irons, aluminium, cobalt, copper, magnesium, nickel, titanium, zinc and any alloys of them. This document does not apply to: - the testing of welded joints (see EN ISO 17636-2); - film radiography (see EN 12681-1); - real time testing with radioscopy (see EN 13068-1; radioscopy with image intensifiers).
This document gives specific procedures for industrial X-ray and gamma radiography for discontinuity detection purposes, using NDT (non-destructive testing) digital X-ray image detectors. This part of the EN 12681 series specifies the requirements for digital radiographic testing by either computed radiography (CR) or radiography with digital detector arrays (DDA) of castings. Digital detectors provide a digital grey value image which can be viewed and evaluated using a computer. NOTE This part of the EN 12681 series complies with EN ISO 16371-2 for CR. Some clauses and annexes are taken from EN ISO 17636-2. This part of the EN 12681 series specifies the recommended procedure for detector selection and radiographic practice. Selection of computer, software, monitor, printer and viewing conditions are important but are not the main focus of this document. The procedure specified in this document provides the minimum requirements for radiographic practice which permit exposure and acquisition of digital images with equivalent sensitivity for detection of imperfections as film radiography, as specified in EN 12681-1. This document does not consider radiographic or radioscopic fitness for purpose testing as applied for specific castings based on manufacturer’s internal requirements and procedures. The requirements on image quality in testing class A and B testing of Annex A consider the good workmanship quality for general casting applications as also required in EN 12681-1 for film radiography. The testing classes AA and BA reflect the quality requirements of current automated and semi-automated radiographic testing systems with DDAs and computer- or operator-based image evaluation, and mini- or micro-focus tubes (spot size ≤ 1 mm) with reduced requirements to the unsharpness, but unchanged requirements to contrast sensitivity as also required in EN 12681-1 for film radiography. The specified procedures are applicable to castings produced by any casting process, especially for steels, cast irons, aluminium, cobalt, copper, magnesium, nickel, titanium, zinc and any alloys of them. This document does not apply to: - the testing of welded joints (see EN ISO 17636-2); - film radiography (see EN 12681-1); - real time testing with radioscopy (see EN 13068-1; radioscopy with image intensifiers).
EN 12681-2:2026 is classified under the following ICS (International Classification for Standards) categories: 77.040.20 - Non-destructive testing of metals. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 12681-2:2026 has the following relationships with other standards: It is inter standard links to EN 12681-2:2017, CEN/TS 17959:2023, EN 1559-5:2017, EN 1559-3:2026. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 12681-2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 wall thickness
- 3.2 nominal wall thickness
- 3.3 penetrated thickness
- 3.4 source size
- 3.5 object-to-detector distance
- 3.6 source-to-object distance
- 3.7 source-to-detector distance
- 3.8 geometric magnification
- 3.9 computed radiography
- 3.10 storage phosphor imaging plate
- 3.11 digital detector array
- 3.12 structure noise of imaging plate
- 3.13 structure noise of digital detector array
- 3.14 grey value
- 3.15 linearized grey value
- 3.16 basic spatial resolution of a digital detector
- 3.17 basic spatial resolution of a digital image
- 3.18 signal-to-noise ratio
- 3.19 normalised signal-to-noise ratio
- 3.20 contrast-to-noise ratio
- 3.21 normalised contrast-to-noise ratio
- 3.22 aliasing
- 3.23 cluster kernel pixels
- 3.24 inherent unsharpness
- 3.25 image unsharpness
- 3.26 total image unsharpness
- 3.27 geometric unsharpness
- 4 Symbols and abbreviated terms
- 5 Classification of radiographic techniques and compensation principles
- 5.1 Classification
- 5.2 Compensation principles
- 6 General preparations and requirements
- 6.1 Protection against ionizing radiation
- 6.2 Surface preparation and stage of manufacture
- 6.3 Agreements
- 6.4 Personnel qualification
- 7 Test arrangements
- 7.1 General
- 7.2 Single wall penetration of plane areas
- 7.3 Single wall penetration of curved areas
- 7.4 Double wall penetration of plane and curved areas
- 7.5 Choice of test arrangements for complex geometries
- 7.6 Acceptable test area dimensions
- 8 Choice of tube potential and radiation source
- 8.1 X-ray devices up to 1 000 kV
- 8.2 Other radiation sources
- 9 Metal screens for IPs and shielding
- 1 MV < X-ray potentials
- 10 Reduction of scattered radiation
- 10.1 Metal filters and collimators
- 10.2 Interception of backscattered radiation
- 11 Source object and detector position
- 11.1 General
- 11.4 Identification of image, test area, detector position plan
- 12 Data processing
- 12.1 Scan and read out of image
- 12.2 Correction of DDAs
- 12.3 Bad pixel interpolation
- 12.4 Image processing
- 13 Monitor viewing conditions and storage of digital images
- 14 Techniques for increasing the covered thickness range
- 14.1 General
- 14.2 Contrast decreasing by higher radiation energy
- 14.3 Beam hardening
- 14.4 Thickness equalization
- 15 Requirements on images
- 15.1 Identification of images
- 15.2 Marking of the test areas
- 15.3 Overlap of digital images
- 16 Image quality
- 16.1 Types and positions of image quality indicators (IQI)
- 16.2 Minimum image quality values
- 16.3 Minimum normalized signal-to-noise ratio (SNRN)
- 16.4 Compensation principle CP II
- 16.5 Regular performance verification of digital radiography systems
- 17 Influence of crystalline structure
Introduction
Radiography can be used to detect internal discontinuities in a casting. The discontinuities can be gas holes, non-metallic inclusions, shrinkage, cracks, inserts or chills or inclusions that have lower or higher densities than the parent metal. This document gives acceptance criteria through severity levels.
SIST EN 12681-2:2027 EN 12681-2:2026 (E)
1 Scope
This document gives specific procedures for industrial X-ray and gamma radiography for discontinuity detection purposes, using NDT (non-destructive testing) digital X-ray image detectors. This part of the EN 12681 series specifies the requirements for digital radiographic testing by either computed radiography (CR) or radiography with digital detector arrays (DDA) of castings. Digital detectors provide a digital grey value image which can be viewed and evaluated using a computer.
NOTE This part of the EN 12681 series complies with EN ISO 16371-2 for CR. Some clauses and annexes are taken from EN ISO 17636-2.
This part of the EN 12681 series specifies the recommended procedure for detector selection and radiographic practice. Selection of computer, software, monitor, printer and viewing conditions are important but are not the main focus of this document. The procedure specified in this document provides the minimum requirements for radiographic practice which permit exposure and acquisition of digital images with equivalent sensitivity for detection of imperfections as film radiography, as specified in EN 12681-1.
This document does not consider radiographic or radioscopic fitness for purpose testing as applied for specific castings based on manufacturer’s internal requirements and procedures. The requirements on image quality in testing class A and B testing of Annex A consider the good workmanship quality for general casting applications as also required in EN 12681-1 for film radiography.
The testing classes A and B reflect the quality requirements of current automated and semi- A A automated radiographic testing systems with DDAs and computer- or operator-based image evaluation, and mini- or micro-focus tubes (spot size ≤ 1 mm) with reduced requirements to the unsharpness, but unchanged requirements to contrast sensitivity as also required in EN 12681-1 for film radiography. The specified procedures are applicable to castings produced by any casting process, especially for steels, cast irons, aluminium, cobalt, copper, magnesium, nickel, titanium, zinc and any alloys of them. This document does not apply to:
- the testing of welded joints (see EN ISO 17636-2);
- film radiography (see EN 12681-1);
- real time testing with radioscopy (see EN 13068-1; radioscopy with image intensifiers).
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN ISO 9712, Non-destructive testing — Qualification and certification of NDT personnel (ISO 9712) EN ISO 17636-2:2022, Non-destructive testing of welds — Radiographic testing — Part 2: X- and gammaray techniques with digital detectors (ISO 17636-2:2022, Corrected version 2023-02) EN ISO 19232-1, Non-destructive testing — Image quality of radiographs — Part 1: Determination of the image quality value using wire-type image quality indicators (ISO 19232-1)
SIST EN 12681-2:2027 EN 12681-2:2026 (E) EN ISO 19232-2, Non-destructive testing — Image quality of radiographs — Part 2: Determination of the image quality value using step/hole-type image quality indicators (ISO 19232-2) EN ISO 19232-4, Non-destructive testing — Image quality of radiographs — Part 4: Experimental evaluation of image quality values and image quality tables (ISO 19232-4) EN ISO 19232-5, Non-destructive testing — Image quality of radiographs — Part 5: Determination of the image unsharpness and basic spatial resolution value using duplex wire-type image quality indicators (ISO 19232-5) ISO 5576, Non-destructive testing — Industrial X-ray and gamma-ray radiology — Vocabulary
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 5576 and EN ISO 17636-2 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https://www.iso.org/obp
- IEC Electropedia: available at https://www.electropedia.org/
3.1 wall thickness
t thickness as measured on the casting
3.2 nominal wall thickness
t n thickness as specified on the drawing
3.3 penetrated thickness
w thickness of material in the direction of the radiation beam calculated on the basis of the real thicknesses of all penetrated walls
3.4 source size
d size of the radiation source or focal spot size [SOURCE: EN ISO 17636-2:2022, 3.20]
3.5 object-to-detector distance
b largest (maximum) distance between the radiation side of the radiographed part of the test object and the sensitive layer of the detector, measured along the central axis of the radiation beam [SOURCE: EN ISO 17636-2:2022, 3.19]
SIST EN 12681-2:2027 EN 12681-2:2026 (E)
3.6 source-to-object distance
f distance between the source of radiation and the source side of the test object, most distant from the detector, measured along the central axis of the radiation beam [SOURCE: EN ISO 17636-2:2022, 3.22]
3.7 source-to-detector distance
SDD distance between the source of radiation and the detector, measured in the direction of the beam Note 1 to entry: SDD = f + b where f is the source-to-object distance; b is the object-to-detector distance [SOURCE: EN ISO 17636-2:2022, 3.21]
3.8 geometric magnification
ratio of source-to-detector distance SDD to source-to-object distance f [SOURCE: EN ISO 17636-2:2022, 3.24]
3.9 computed radiography
CR storage phosphor imaging plate system complete system comprising a storage phosphor imaging plate (IP) and a corresponding read out unit (scanner or reader), which converts the information from the IP into a digital image [SOURCE: EN ISO 17636-2:2022, 3.1]
3.10 storage phosphor imaging plate
IP photostimulable luminescent material capable of storing a latent radiographic image of a material being tested and, upon stimulation by a source of red light of appropriate wavelength, generates luminescence proportional to radiation absorbed Note 1 to entry: When performing computed radiography, an IP is used in lieu of a film. When establishing techniques related to source size or focal geometries, the IP is referred to as a detector, i.e. source-to-detector distance (SDD).
[SOURCE: EN ISO 17636-2:2022, 3.2]
SIST EN 12681-2:2027 EN 12681-2:2026 (E)
3.11 digital detector array
DDA electronic device converting ionizing or penetrating radiation into a discrete array of analogue signals which are subsequently digitized and transferred to a computer for display as a digital image corresponding to the radiologic energy pattern imparted upon the input region of the device [SOURCE: EN ISO 17636-2:2022, 3.3]
3.12 structure noise of imaging plate
structure noise of IP local sensitivity variations due to inhomogeneities in the sensitive layer (structure, graininess) and surface of an imaging plate Note 1 to entry: After scanning of the exposed imaging plate the inhomogeneities appear as overlaid fixed pattern noise in the digital image.
Note 2 to entry: This noise limits the maximum achievable image quality of digital CR images and can be compared with the graininess in film images.
[SOURCE: EN ISO 17636-2:2022, 3.4]
3.13 structure noise of digital detector array
structure noise of DDA local sensitivity variations due to different properties of detector elements (pixels) Note 1 to entry: After read out of the exposed uncorrected DDA, the inhomogeneities of the DDA appear as overlaid fixed pattern noise in the digital image. Therefore, all DDAs require after read-out a software-based correction procedure (software and guidelines are provided by the manufacturer). A suitable correction procedure reduces the structure noise.
Note 2 to entry: The image correction is also called “calibration” in other documents. [SOURCE: EN ISO 17636-2:2022, 3.5]
3.14 grey value
GV numeric value of a pixel in a digital image Note 1 to entry: This is typically interchangeable with the terms pixel value, detector response, analogue-to-digital unit, and detector signal.
Note 2 to entry: For further information, see Annex H.
[SOURCE: EN ISO 17636-2:2022, 3.6]
SIST EN 12681-2:2027 EN 12681-2:2026 (E)
3.15 linearized grey value
GV lin numeric value of a pixel which is directly proportional to the detector exposure dose, having a value of zero if the detector was not exposed Note 1 to entry: This is typically interchangeable with the terms linearized pixel value, and linearized detector signal.
[SOURCE: EN ISO 17636-2:2022, 3.7, modified – “GV “has been added.] lin
3.16 basic spatial resolution of a digital detector
detector SR b half of the measured detector unsharpness in a digital image, which corresponds to the effective pixel size and indicates the smallest geometrical detail, which can be resolved with a digital detector at magnification equal to one Note 1 to entry: For this measurement, the duplex wire IQI is placed directly on the digital detector array or imaging plate.
Note 2 to entry: The measurement of unsharpness is described in EN ISO 19232-5, see also ASTM E 2736-17 (2022) and ASTM E 1000-24.
[SOURCE: EN ISO 17636-2:2022, 3.8]
3.17 basic spatial resolution of a digital image
image SR b half of the measured image unsharpness in a digital image, which corresponds to the effective pixel size and indicates the smallest geometrical detail, which can be resolved in a digital image Note 1 to entry: For this measurement, the duplex wire IQI is placed directly on the object (source side). Note 2 to entry: The measurement of unsharpness is described in EN ISO 19232-5, see also ASTM E 2736-17 (2022), and ASTM E 1000-24.
[SOURCE: EN ISO 17636-2:2022, 3.9]
3.18 signal-to-noise ratio
SNR ratio of mean value of the linearized grey values to the standard deviation of the linearized grey values (noise) in a given region of interest in a digital image Note 1 to entry: The region of interest shall contain at least 1 100 pixels.
SIST EN 12681-2:2027 EN 12681-2:2026 (E)
3.19 normalised signal-to-noise ratio
SNR N image SNR, normalised by the basic spatial resolution SR as measured directly in the digital image and/or b calculated from measured SNR image Note 1 to entry: SNRN = SNR ∙ c / SRb ; c = 0,088 6 mm.
image Note 2 to entry: SRb is used for images with magnification.
3.20 contrast-to-noise ratio
CNR ratio of the difference of the mean signal levels between two image areas to the averaged standard deviation of the signal levels Note 1 to entry: Signal levels are measured in grey values or linearized grey values. Note 2 to entry: The contrast-to-noise ratio describes a component of image quality and depends approximately on the product of radiographic attenuation coefficient and SNR. In addition to adequate CNR, it is also necessary for a digital radiograph to possess adequate unsharpness or basic spatial resolution to resolve desired features of interest.
[SOURCE: EN ISO 17636-2:2022, 3.12]
3.21 normalised contrast-to-noise ratio
CNR N image CNR, normalised by the basic spatial resolution SR as measured directly in the digital image and/or b calculated from measured CNR image Note 1 to entry: CNRN = CNR ∙ c / SRb ; c = 0,088 6 mm.
3.22 aliasing
artefacts that appear in an image when the spatial frequency of the input is higher than the output is capable of reproducing Note 1 to entry: Aliasing often appears as jagged or stepped sections in a line or as moiré patterns. [SOURCE: EN ISO 17636-2:2022, 3.14]
3.23 cluster kernel pixels
CKP bad pixels which do not have five or more good neighbourhood pixels Note 1 to entry: See ASTM E 2597/E 2597M-22 for details on bad pixels and CKP. [SOURCE: EN ISO 17636-2:2022, 3.15]
SIST EN 12681-2:2027 EN 12681-2:2026 (E)
3.24 inherent unsharpness
u
unsharpness of the detector system, excluding any geometric unsharpness, measured from the digital image with a duplex wire IQI adjacent to the detector detector Note 1 to entry: ui = 2 ∙ SRb
3.25 image unsharpness
u im unsharpness measured in the digital image at the object plane with a duplex wire IQI at this plane too
3.26 total image unsharpness
u T including geometric and inherent unsharpness, measured in the digital image at the detector plane with a duplex wire IQI at the object plane Note 1 to entry: uT is calculated by the following formula:
u uu+ T Gi
3.27 geometric unsharpness
uG unsharpness measured in the digital image at the detector plane with a duplex wire IQI at the object plane with a high resolution detector excluding the inherent detector unsharpness Note 1 to entry: u is calculated by the following formula:
G b ud⋅ G f
4 Symbols and abbreviated terms
For the purposes of this document, the following symbols and abbreviations apply:
w penetrated thickness t wall thickness t nominal wall thickness n b object-to-detector distance d source size f source-to-object distance f minimum source-to-object distance min S source of radiation D radiographic detector SDD source-to-detector distance
SIST EN 12681-2:2027 EN 12681-2:2026 (E) v geometric magnification CR computed radiography IP storage phosphor imaging plate DDA digital detector array system D diagonal size of the detector area d GV grey value GV linearized grey value lin IQI image quality indicator detector SR basic spatial resolution of a digital detector b image SR basic spatial resolution of a digital image b SNR signal-to-noise ratio SNR normalized signal-to-noise ratio N CNR contrast-to-noise ratio CNR normalized contrast-to-noise ratio N u geometric unsharpness G CKP cluster kernel pixel u inherent detector unsharpness.
d u image unsharpness im u total image unsharpness T
5 Classification of radiographic techniques and compensation principles
5.1 Classification
The radiographic techniques for film replacement are divided into two testing classes:
- Testing class A: basic techniques;
- Testing class B: improved techniques.
The techniques for automated DDA based testing are divided into two testing classes:
- Testing class A : basic automated techniques; A
- Testing class B : improved automated technique.
A NOTE Automated DDA based techniques are used in industry for fast testing of castings mainly in serial production. These automated techniques are not considered as film replacement technique. It is recommended to perform the testing according to testing class A or A , if not otherwise specified in A the order, testing class B or B techniques are used when testing class A or A are insufficiently A A sensitive. This document does not cover fitness for purpose testing with IQI requirements different from Table A.1 to Table A.3.
SIST EN 12681-2:2027 EN 12681-2:2026 (E) Automated testing in the testing classes A and B , shall fulfil the contrast sensitivity requirements A A (Table A.1 and Table A.2) of testing class A or B, but reduced unsharpness requirements as specified in Annex A, Table A.4.
If, for technical or industrial reasons, it is not possible to meet one of the conditions specified for testing class B, such as the energy of radiation source or the source to object distance f, the condition selected may be what is specified for testing class A. The loss of sensitivity shall be compensated by an increase of minimum grey value and SNR for CR or SNR for the DDA-technique (recommended increase of N N SNR by a factor > 1,4). Because of the better sensitivity compared to testing class A, the casting may be N regarded as being tested to testing class B, if the correct IQI sensitivity is achieved. This does not apply if the special SDD reduction as specified in Clause 11 for test arrangements Figure 3 and Figure 4 are used.
5.2 Compensation principles
Three rules to be applied in this document for radiography with digital detectors to achieve sufficient contrast sensitivity.
This requires achieving a minimum contrast-to-noise ratio, normalized to the detector basic spatial resolution (CNR ) per detectable material thickness difference Δw. If the required normalized contrast- N to-noise ratio (CNR per Δw) cannot be achieved due to an insufficient value of one of the following N parameters, this can be compensated by an increase in the signal to noise ratio (SNR):
CP I: Compensation for reduced contrast (e.g. by increased tube potential (voltage)) by increased SNR (e.g. by increased tube current or exposure time).
image CP II: Compensation for insufficient detector sharpness (the value of SR higher than specified) b by increased SNR (increase in the single IQI wire or step hole value for each missing duplex wire pair value).
CP III: Compensation for increased local interpolation unsharpness, due to bad pixel correction for DDAs, by increased SNR.
These compensation principles are based on the following approximation for small discontinuity sizes (Δw < < w), see Formula (1):
CNR µ ⋅ SNR N eff (1) = const ⋅ image ∆w SR b where μ effective attenuation coefficient, which is equivalent to the specific material contrast; eff CNR normalized CNR, as measured in the digital image.
N
6 General preparations and requirements
6.1 Protection against ionizing radiation
WARNING — Exposure of any part of the human body to X-rays or gamma-rays can be highly injurious to health. Wherever X-ray equipment or radioactive sources are in use, appropriate safety requirements shall be applied.
NOTE Local, national or international safety precautions are especially important to apply when using ionizing radiation.
SIST EN 12681-2:2027 EN 12681-2:2026 (E)
6.2 Surface preparation and stage of manufacture
In general, surface preparation is not necessary, but where surface imperfections can cause difficulties in detecting discontinuities, the surface shall be ground smooth. NOTE Surface roughness and internal granularity of test objects appear in digital images similar to image noise. This can hide small discontinuities and reduce the IQI sensitivity. Unless otherwise specified digital radiography shall be carried out after the final stage of manufacture, e.g. after grinding or heat treatment.
For some aluminium and magnesium alloy castings, radiography may be carried out before heat treatment.
6.3 Agreements
Castings with a complex geometry can include areas which cannot be tested by radiography or can only be partly tested. Such areas shall be identified before starting the radiographic testing. Areas which cannot be tested by radiography shall be noted by all contracting parties and be marked on the exposure plan.
The following items shall be as agreed at the time of order:
a) manufacturing stage; b) extent of radiographic testing; c) test areas; d) surface condition; e) testing class; f) information about the detector position plan; g) marking of test areas on the casting; image detector h) image quality requirements (IQI wire or step hole, SR , SR , SNR ); b b N i) marking of the radiographs; j) acceptance criteria; k) any additional items; l) any special requirements, e.g. minimum dimensions of discontinuities to detect.
...