Safety of escalators and moving walks - Part 1: Construction and installation

1.1   This standard is applicable for new escalators and moving walks (pallet or belt type) as defined in Clause 3.
This standard deals with all significant hazards, hazardous situations and events relevant to escalators and moving walks when they are used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer (see Clause 4).
1.2   This standard does not deal with hazards arising from seismic activities.
1.3   This document is not applicable to escalators and moving walks which were manufactured before the date of its publication as EN. It is, however, recommended that existing installations be adapted to this standard.

Sicherheit von Fahrtreppen und Fahrsteigen - Teil 1: Konstruktion und Einbau

1.1   Diese Norm gilt für neue Fahrtreppen und Fahrsteige (Paletten- oder Gurtkonstruktion) wie im Abschnitt 3 angegeben.
Diese Norm behandelt alle für Fahrtreppen und Fahrsteige signifikanten Gefährdungen, Gefährdungs-situationen und Gefährdungsereignisse (wie in Abschnitt 4 angegeben), wenn sie bestimmungsgemäß und unter Bedingungen, die vom Hersteller als Fehlanwendung vernünftigerweise vorhersehbar sind, verwendet werden.
1.2   Diese Norm behandelt keine Gefährdungen, die durch seismische Aktivitäten hervorgerufen werden.
1.3   Dieses Dokument gilt nicht für Fahrtreppen und Fahrsteige, die hergestellt wurden, bevor CEN dieses Dokument veröffentlichte. Es wird jedoch empfohlen, dass bestehende Anlagen an diese Norm angepasst werden.

Sécurité des escaliers mécaniques et trottoirs roulants - Partie 1: Construction et installation

1.1   La présente norme est applicable aux nouveaux escaliers mécaniques et trottoirs roulants (à palettes ou à bande) tels que définis à l’Article 3.
Cette norme prend en compte tous les risques significatifs, les situations et événements dangereux relatifs aux escaliers mécaniques et trottoirs roulants, utilisés conformément à l’usage pour lequel ils ont été prévus ainsi que dans des cas d’utilisations inappropriées qui peuvent être raisonnablement prévisibles par le constructeur (voir Article 4).
1.2   Cette norme ne prend pas en compte les risques émanant de l’activité sismique.
1.3   Le présent document ne s’applique pas aux escaliers mécaniques et trottoirs roulants fabriqués avant la date de publication de ce document en tant que norme EN. Il est toutefois recommandé que les installations existantes soient adaptées à cette norme.
NOTE   Pour ce type particulier de machines le bruit n’est pas considéré comme un risque significatif ou pertinent.

Varnost tekočih stopnic in trakov za osebe (stez) - 1. del: Konstrukcija in vgradnja

General Information

Status
Withdrawn
Publication Date
29-Jul-2008
Withdrawal Date
23-Mar-2010
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
24-Mar-2010
Completion Date
24-Mar-2010

Relations

Buy Standard

Standard
EN 115-1:2009
English language
91 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Sicherheit von Fahrtreppen und Fahrsteigen - Teil 1: Konstruktion und EinbauSafety of escalators and moving walks - Part 1: Construction and installation91.140.90Lifts. EscalatorsICS:Ta slovenski standard je istoveten z:EN 115-1:2008SIST EN 115-1:2009en,fr,de01-april-2009SIST EN 115-1:2009SLOVENSKI
STANDARDSIST EN 115:1997/A2:2004SIST EN 115:1997/A1:19991DGRPHãþD

EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 115-1July 2008ICS 91.140.90Supersedes EN 115:1995
English VersionSafety of escalators and moving walks - Part 1: Constructionand installationSécurité des escaliers mécaniques et trottoirs roulants -Partie 1: Construction et installationSicherheit von Fahrtreppen und Fahrsteigen - Teil 1:Konstruktion und EinbauThis European Standard was approved by CEN on 29 May 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2008 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 115-1:2008: ESIST EN 115-1:2009

Building interfaces.61 Annex B (normative)
Electronic components - Failure exclusion.66 Annex C (normative)
Drafting and assessing fail safe circuits.71 Annex D (normative)
Testing of fail safe circuits containing electronic components.72 Annex E (informative)
Design guide-line for safety circuits.75 Annex F (informative)
Examples of possible dynamic torsional tests for steps and pallets.76 Annex G (normative)
Safety signs for the user of escalators and moving walks.79 Annex H (informative)
Guidelines for selection and planning of escalators and moving walks.81 Annex I (normative)
Requirements on escalators and moving walks intended to transport shopping trolleys and baggage carts.82 Annex J (informative)
Determination of anti-slip properties of the tread surfaces of steps and pallets, of comb plates and cover plate.84 Annex K (informative)
Determination of sliding properties of footwear on balustrade skirting.86 Annex L (informative)
Interpretations of EN 115-1:2008.87 Annex ZA (informative)
Relationship between this European Standard and the Essential Requirements of Directive 98/37/EC.89 Annex ZB (informative)
Relationship between this European Standard and the Essential Requirements of Directive 2006/42/EC.90 Bibliography.91
 taking over the agreed upon points from the work carried out by ISO/TC 178/WG 5;  adapting the requirements to the state of the art using the risk assessment methodology as given in ISO/TS 14798:2006 [1];  improving the references to other standards according to the progress in that field;  covering the requirements of CEN Guide 414 by creating a new structure which addresses the safety rules for the machine and provides requirements in the normative annexes and information in the informative annexes;  increasing the measures against foreseeable misuse;  reviewing the safety requirements for escalators and moving walks;  discussing the comments arising from the CEN Enquiry. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. SIST EN 115-1:2009

Some individuals, in particular older people, might have more than one impairment. Some individuals are not able to use an escalator or moving walk independently and rely on assistance/support being provided by a companion. Furthermore some individuals can be encumbered by objects or be responsible for other persons, which can affect their mobility. The extent to which an individual is incapacitated by impairments and encumbrances often depends on the usability of products, facilities and the environment. The use of wheelchairs on escalators and moving walks can lead to dangerous situations which cannot be mitigated by machine designs and therefore should not be permitted. The use of lifts is the preferred method of vertical travel for most people with disabilities and in particular wheelchair users and persons w
...